[{"data":1,"prerenderedAt":2105},["ShallowReactive",2],{"blog-post-nl-warmtepomp-eendraadschema":3,"blog-alternates-heat-pump-single-line-diagram":493},{"id":4,"title":5,"articleId":6,"body":7,"category":471,"date":472,"description":473,"extension":474,"lastUpdated":472,"locale":475,"meta":476,"navigation":477,"path":478,"publishDate":472,"readTime":479,"refreshInterval":480,"seo":481,"slug":482,"stem":483,"tags":484,"__hash__":492},"blog\u002Fblog\u002Fheat-pump-single-line-diagram.nl.md","Warmtepomp op het eendraadschema: kring en gegevens correct tekenen","heat-pump-single-line-diagram",{"type":8,"value":9,"toc":448},"minimark",[10,19,22,27,30,58,61,65,68,71,82,85,91,105,109,112,139,148,152,155,172,180,184,187,207,219,223,234,251,259,263,268,271,275,278,282,285,289,292,296,299,319,322,326,329,332,352,355,359,362,365,368,372,375,378,398,401,404,407,411,414,423,427,435,439],[11,12,13,14,18],"p",{},"Een warmtepomp is elektrisch vaak meer dan één toestel. Naast een buitenunit kunnen een binnenmodule, elektrische bijverwarming, circulatiepomp, regeling en sanitair-warmwaterboiler aanwezig zijn. Sommige onderdelen delen één voeding, andere hebben elk een eigen kring. Het eendraadschema moet die ",[15,16,17],"strong",{},"werkelijk uitgevoerde elektrische structuur"," tonen en mag niet worden afgeleid uit het vereenvoudigde hydraulische verkoopschema.",[11,20,21],{},"AREI Boek 1 V06 legt geen universeel warmtepompsymbool, automaat of differentieeltype voor ieder merk vast. De algemene regels voor kringen, bescherming, leidingen en documentatie gelden samen met de elektrische installatievoorschriften van het exacte toestel. Een betrouwbaar schema maakt die combinatie controleerbaar.",[23,24,26],"h2",{"id":25},"verzamel-eerst-de-elektrische-brongegevens","Verzamel eerst de elektrische brongegevens",[11,28,29],{},"Controleer vóór het tekenen het verdeelbord, de typeplaten en alle relevante installatiehandleidingen. Noteer per elektrisch gevoed onderdeel:",[31,32,33,37,40,43,46,49,52,55],"ul",{},[34,35,36],"li",{},"toestelreferentie en functie;",[34,38,39],{},"voedingsspanning, één- of driefasige aansluiting;",[34,41,42],{},"nominale stroom en door de fabrikant gevraagde maximale beveiliging;",[34,44,45],{},"aanwezigheid van inverter- of frequentieregeling;",[34,47,48],{},"voorgeschreven aardlekbeveiliging en informatie over mogelijke DC-componenten;",[34,50,51],{},"kabeltype, aantal geleiders, doorsnede en werkelijk traject;",[34,53,54],{},"lokale werkschakelaar of scheidingsinrichting, indien geplaatst;",[34,56,57],{},"afzonderlijke voeding voor elektrische weerstand, regeling, pomp of boiler.",[11,59,60],{},"Een thermisch vermogen van bijvoorbeeld 8 kW is niet hetzelfde als het elektrisch opgenomen vermogen of het aansluitvermogen. Gebruik op het elektrische schema alleen de passende elektrische gegevens.",[23,62,64],{"id":63},"eén-kring-of-meerdere-takken","Eén kring of meerdere takken?",[11,66,67],{},"Een monoblock kan één voedingspunt hebben. Bij een split-installatie kunnen buiten- en binnenunit afzonderlijk worden gevoed. Een ingebouwde weerstand kan via dezelfde aansluiting werken, maar kan ook een afzonderlijke, zwaarder belaste kring vereisen. De regeling kan vanuit de binnenunit gevoed worden of een eigen beveiliging hebben.",[11,69,70],{},"Teken daarom niet blind:",[72,73,79],"pre",{"className":74,"code":76,"language":77,"meta":78},[75],"language-text","Verdeelbord → automaat → warmtepomp\n","text","",[80,81,76],"code",{"__ignoreMap":78},[11,83,84],{},"Een mogelijke werkelijke structuur is:",[72,86,89],{"className":87,"code":88,"language":77,"meta":78},[75],"Hoofdverdeelbord\n├─ kring WP1 → beveiliging → leiding → buitenunit\u002Finverter\n├─ kring WP2 → beveiliging → leiding → binnenunit\u002Fregeling\n└─ kring WP3 → beveiliging → leiding → elektrische bijverwarming\n",[80,90,88],{"__ignoreMap":78},[11,92,93,96,97,100,101,104],{},[80,94,95],{},"WP1",", ",[80,98,99],{},"WP2"," en ",[80,102,103],{},"WP3"," zijn slechts voorbeelden. Sluit aan bij de kringletters van het project en gebruik exact dezelfde referenties op het situatieschema.",[23,106,108],{"id":107},"gegevens-bij-elke-aftakking","Gegevens bij elke aftakking",[11,110,111],{},"Van verdeelbord tot verbruiker moet de keten leesbaar zijn. Vermeld minstens:",[113,114,115,118,121,124,127,130,133,136],"ol",{},[34,116,117],{},"kringreferentie;",[34,119,120],{},"type, aantal polen en nominale stroom van de overstroombeveiliging;",[34,122,123],{},"aanwezige differentieelbeveiliging met aanspreekstroom en type;",[34,125,126],{},"kabel- of draadtype, aantal geleiders en doorsnede;",[34,128,129],{},"faseverdeling bij een meerfasige aansluiting;",[34,131,132],{},"ondubbelzinnige naam, bijvoorbeeld “warmtepomp buitenunit”;",[34,134,135],{},"relevant elektrisch vermogen of nominale stroom;",[34,137,138],{},"vaste scheider, contactor of vermogenssturing als die werkelijk deel uitmaakt van de installatie.",[11,140,141,142,147],{},"De ",[143,144,146],"a",{"href":145},"\u002Fblog\u002Fkabeldoorsnede-automaat","kabeldoorsnede bij een automaat"," volgt niet alleen uit het toestelvermogen. Lengte, plaatsingswijze, bundeling, omgevingstemperatuur, spanningsval, kortsluitvoorwaarden en fabrikantvoorschriften blijven bepalend.",[23,149,151],{"id":150},"differentieel-geen-universele-keuze","Differentieel: geen universele keuze",[11,153,154],{},"Een compressor met vermogenselektronica kan andere foutstroomvormen veroorzaken dan een zuiver resistieve belasting. Dat maakt type B niet automatisch verplicht voor elke warmtepomp en maakt type A evenmin automatisch geschikt. Controleer samenhangend:",[31,156,157,160,163,166,169],{},[34,158,159],{},"de handleiding van het exacte model en de geïnstalleerde optiekaarten;",[34,161,162],{},"eventuele ingebouwde detectie van gladde gelijkfoutstromen;",[34,164,165],{},"het aardingsstelsel en de ontworpen uitschakelvoorwaarden;",[34,167,168],{},"selectiviteit en verdeling tegenover bovenliggende differentiëlen;",[34,170,171],{},"normale lekstromen van andere toestellen op dezelfde beveiliging.",[11,173,174,175,179],{},"In ",[143,176,178],{"href":177},"\u002Fblog\u002Fdifferentieel-type-a-vs-type-b","differentieel type A versus type B"," worden foutstroomvorm, verhoogde immuniteit en selectiviteit afzonderlijk behandeld. Noteer op het schema wat werkelijk geplaatst is, niet wat een algemene vuistregel suggereert.",[23,181,183],{"id":182},"symbool-en-legende","Symbool en legende",[11,185,186],{},"Tabel 2.23 van AREI Boek 1 V06 is niet uitputtend. Als geen standaardteken de geïnstalleerde warmtepompconfiguratie duidelijk beschrijft, kan een ondubbelzinnig teken of blok worden gebruikt dat in de legende wordt verklaard. U kunt bijvoorbeeld onderscheiden:",[31,188,189,195,201],{},[34,190,191,194],{},[80,192,193],{},"WP-B",": warmtepomp buitenunit;",[34,196,197,200],{},[80,198,199],{},"WP-I",": warmtepomp binnenunit;",[34,202,203,206],{},[80,204,205],{},"BV",": elektrische bijverwarming.",[11,208,209,210,213,214,218],{},"Gebruik hetzelfde symbool en dezelfde betekenis doorheen het volledige dossier. Vermijd dat ",[80,211,212],{},"WP"," elders “waterpomp” betekent. De ",[143,215,217],{"href":216},"\u002Fblog\u002Farei-elektrische-symbolen-overzicht","AREI-symbolengids"," legt uit wanneer een eigen legende nodig is.",[23,220,222],{"id":221},"samenhang-met-het-situatieschema","Samenhang met het situatieschema",[11,224,225,226,229,230,233],{},"Het eendraadschema toont ",[15,227,228],{},"hoe"," de warmtepomp gevoed en beschermd wordt. Het situatieschema toont ",[15,231,232],{},"waar"," vaste elektrische onderdelen zich bevinden. Plaats, afhankelijk van de installatie:",[31,235,236,239,242,245,248],{},[34,237,238],{},"buiten- en binnenunit;",[34,240,241],{},"werkschakelaar of lokale scheider;",[34,243,244],{},"regelkast of onderverdeelkast;",[34,246,247],{},"vaste elektrische weerstand;",[34,249,250],{},"relevante vaste kabeltrajecten wanneer die voor onderhoud of veiligheid nodig zijn.",[11,252,253,254,258],{},"Elk element krijgt dezelfde kringreferentie als op het eendraadschema. Een hydraulisch principe- of leidingplan kan nuttig zijn, maar vervangt de elektrische plannen niet. Zie ook ",[143,255,257],{"href":256},"\u002Fblog\u002Feendraadschema-vs-situatieschema","eendraadschema versus situatieschema",".",[23,260,262],{"id":261},"fouten-die-een-schema-onbetrouwbaar-maken","Fouten die een schema onbetrouwbaar maken",[264,265,267],"h3",{"id":266},"alleen-warmtepomp-8-kw-vermelden","Alleen “warmtepomp 8 kW” vermelden",[11,269,270],{},"Dat is vaak thermisch vermogen. Zonder voedingswijze, beveiliging en leiding kan niemand de elektrische tak reconstrueren.",[264,272,274],{"id":273},"de-bijverwarming-vergeten","De bijverwarming vergeten",[11,276,277],{},"Een elektrische weerstand kan de aansluitpiek sterk verhogen en een afzonderlijke voeding hebben. Toon ze als ze tot de vaste installatie behoort.",[264,279,281],{"id":280},"een-generieke-beveiliging-kopiëren","Een generieke beveiliging kopiëren",[11,283,284],{},"Een voorbeeldschema van een ander model bewijst niet dat hetzelfde differentieeltype, dezelfde karakteristiek of dezelfde doorsnede geschikt is.",[264,286,288],{"id":287},"ontwerp-en-as-built-verwarren","Ontwerp en as-built verwarren",[11,290,291],{},"Tijdens de montage kunnen fase, leidingstraject of toestelvariant wijzigen. Werk schema, bordetiketten en dossier pas bij na controle ter plaatse.",[23,293,295],{"id":294},"controle-vóór-oplevering","Controle vóór oplevering",[11,297,298],{},"Loop ten minste deze punten na:",[31,300,301,304,307,310,313,316],{},[34,302,303],{},"stemmen typeplaat en toestelnaam overeen met het schema;",[34,305,306],{},"zijn buitenunit, binnenunit en elektrische hulpcomponenten volledig;",[34,308,309],{},"komen pooltal, nominale stroom en differentieelgegevens overeen met de geplaatste apparaten;",[34,311,312],{},"zijn leidinggegevens en faseverdeling traceerbaar;",[34,314,315],{},"zijn kringreferenties gelijk op bord, eendraadschema en situatieschema;",[34,317,318],{},"zitten fabrikantdocumentatie en latere wijzigingen in het installatiedossier?",[11,320,321],{},"Dit is een documentatiecontrole. Ze vervangt geen elektrische berekening, vakbekwame uitvoering of controle door een erkend organisme.",[23,323,325],{"id":324},"wanneer-moet-het-schema-opnieuw-worden-aangepast","Wanneer moet het schema opnieuw worden aangepast?",[11,327,328],{},"Niet alleen de vervanging van de volledige warmtepomp is relevant. Herbekijk de documenten wanneer een weerstand wordt bijgeplaatst, een hoger elektrisch vermogen wordt geactiveerd, een éénfasig toestel door een driefasige variant wordt vervangen of een externe regeling vast wordt aangesloten. Een wijziging aan differentieel, automaat, kabel of faserichting hoort eveneens in de as-built versie.",[11,330,331],{},"Vergelijk bij zo’n ingreep systematisch:",[31,333,334,337,340,343,346,349],{},[34,335,336],{},"oude en nieuwe elektrische aansluitgegevens;",[34,338,339],{},"bestaande kabel en werkelijk beschikbare geleiders;",[34,341,342],{},"geplaatste beveiliging tegenover de nieuwe fabrikantvoorwaarden;",[34,344,345],{},"faseverdeling en belasting van het verdeelbord;",[34,347,348],{},"gewijzigde locaties op het situatieschema;",[34,350,351],{},"documentversie en bijbehorende handleidingen.",[11,353,354],{},"Een buiten dienst gestelde kring die fysiek blijft liggen, moet als zodanig begrijpelijk zijn. Een schema dat een afgekoppeld toestel nog als actief toont, is even misleidend als een nieuwe bijverwarming die nergens voorkomt. Vermeld niet alleen de commerciële familienaam: modelvariant, elektrische optie en voedingswijze bepalen of de oude tekening nog bruikbaar is.",[23,356,358],{"id":357},"praktijkvoorbeeld-buitenunit-binnenmodule-en-bijverwarming","Praktijkvoorbeeld: buitenunit, binnenmodule en bijverwarming",[11,360,361],{},"Stel dat een installatie een driefasige buitenunit, een afzonderlijk gevoede binnenmodule en elektrische bijverwarming heeft. Teken niet meteen één algemeen blok. Controleer bij het geleverde model en de echte bekabeling of drie eindstroombanen bestaan dan wel of onderdelen intern vanuit de buitenunit gevoed worden. Alleen werkelijk gescheiden kringen krijgen een eigen beveiligingsketen, leidinggegevens en referentie.",[11,363,364],{},"Noteer per echte tak de maximale elektrische opname uit de bindende fabrikantdocumentatie, niet het thermische verwarmingsvermogen uit een verkoopbrochure. Geef fasen, nulgeleider en beschermingsgeleider volgens de geplaatste kabel aan. Naast een driefasige buitenunit kan een eenfasige regelaar of binnenmodule staan; de gezamenlijke functie “warmtepomp” maakt dat onderscheid niet onbelangrijk. Controleer vooral de bijverwarming, omdat aansluitvermogen en trappen veel hoger kunnen zijn dan het compressorverbruik.",[11,366,367],{},"Plaats buitenunit, binnenmodule, vaste scheidingsmogelijkheid en afzonderlijk gevoede bijverwarming op hun werkelijke plaats in het situatieplan. Teken besturings-, bus- of sensorleidingen niet als vermogenskring. Zijn ze belangrijk voor onderhoud, leg ze dan uit in legende of technische documentatie zonder ze met de netvoeding te vermengen.",[23,369,371],{"id":370},"inbedrijfstelling-en-bedrijfsmodi-meenemen","Inbedrijfstelling en bedrijfsmodi meenemen",[11,373,374],{},"Vergelijk de getekende aftakking na ingebruikname met typeplaten, klemmen, installateursinstellingen en testgegevens. Vermogensbegrenzing, blokkeercontact of energiemanagement kan de werking beïnvloeden, maar vervangt niet automatisch de deskundige dimensionering en beoordeling van beveiligingen. Documenteer alleen instellingen die werkelijk zijn toegepast, tegen onbedoelde wijziging beschermd zijn en voor de ontwerpgrondslag meetellen.",[11,376,377],{},"Controleer bedrijfsgevallen die tijdens normaal verwarmen gemakkelijk verborgen blijven:",[31,379,380,383,386,389,392,395],{},[34,381,382],{},"ontdooien met gelijktijdige bijverwarming;",[34,384,385],{},"nood- of hygiënebedrijf via de elektrische weerstand;",[34,387,388],{},"start- en omvormergedrag volgens de fabrikant;",[34,390,391],{},"aparte voeding voor lekbak- of traceverwarming;",[34,393,394],{},"veilig scheiden voor onderhoud;",[34,396,397],{},"herstart na netonderbreking of lastafschakeling.",[11,399,400],{},"Deze lijst schrijft geen universele automaat, differentieel of kabeldoorsnede voor. Ze toont welke gegevens de ontwerper met de exacte handleiding en plaatsingsvoorwaarden moet oplossen. Metingen en uitschakelvoorwaarden blijven controles op locatie.",[11,402,403],{},"Leg ook vast welke component na uitschakeling van de hoofdkring nog spanning kan voeren. Een regelmodule, communicatievoeding of afzonderlijk hulpapparaat kan een andere voeding hebben. Een onderhoudsschema mag die hulpvoeding niet verbergen. Geef scheidingspunten alleen als gezamenlijk werkend aan wanneer bekabeling en fabrikantconcept dat bevestigen. Zo voorkomt het dossier dat een zogenaamd volledig uitgeschakeld systeem ongemerkt uit een tweede kring gevoed blijft.",[11,405,406],{},"Neem dat onderscheid ook over op de labels in het verdeelbord. Eén verzamelnaam voor meerdere aftakkingen maakt onderhoud en plancontrole moeilijk. Gebruik korte functienamen en dezelfde referenties op schema, situatieplan en toestel. Controleer na het etiketteren door gericht vrijschakelen of elke aanduiding werkelijk het verwachte onderdeel betreft. Dat resultaat hoort bij de as-built afstemming en mag niet uit het ontwerp worden verondersteld.",[23,408,410],{"id":409},"koppeling-met-pv-batterij-en-lastbeheer","Koppeling met PV, batterij en lastbeheer",[11,412,413],{},"Een warmtepomp kan op zelfverbruikssturing reageren, maar staat daardoor niet elektrisch “achter de PV-omvormer” wanneer de werkelijke AC-topologie anders is. Teken energiepaden volgens de echte aansluiting en beschrijf communicatie- of smart-gridcontacten apart. Stel bij noodvoeding vast of de warmtepomp echt door het noodstroombord wordt gevoed en of start- en vermogensgrenzen dat toelaten. Een instelling in een app bewijst de bekabeling niet.",[11,415,141,416,422],{},[143,417,421],{"href":418,"rel":419},"https:\u002F\u002Feconomie.fgov.be\u002Fnl\u002Fpublicaties\u002Falgemeen-reglement-op-de",[420],"nofollow","officiële publicatie van AREI Boek 1"," vormt het algemene kader voor schema en beveiliging. Modelgebonden ingangswaarden, externe beveiligingseisen en aansluitvarianten komen uit de actuele handleiding van exact het geplaatste toestel.",[23,424,426],{"id":425},"documenteren-met-planelec","Documenteren met PlanElec",[11,428,429,430,434],{},"Met ",[143,431,433],{"href":432},"\u002F","PlanElec"," koppelt u warmtepomponderdelen aan de werkelijk uitgevoerde kringen, legt u beveiligings- en leidinggegevens vast en exporteert u eendraadschema en situatieschema als PDF. Voor projectspecifieke tekens blijft een heldere legende nodig. De oriënterende zelfcheck kan ondersteunde invoer signaleren, maar garandeert geen AREI-conformiteit, fabrikantgoedkeuring of officieel keuringsverslag.",[23,436,438],{"id":437},"bronnen-en-geldigheidsstand","Bronnen en geldigheidsstand",[11,440,441,442,447],{},"De inhoud steunt op de officiële publicatie van ",[143,443,446],{"href":444,"rel":445},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[420],"AREI\u002FRGIE Boek 1",", vooral tabel 2.23 en deel 3 over elektrische plannen, aangevuld met de elektrische installatiehandleiding van het concrete warmtepompmodel. Gecontroleerde stand: Boek 1 V06, 29 augustus 2026.",{"title":78,"searchDepth":449,"depth":449,"links":450},2,[451,452,453,454,455,456,457,464,465,466,467,468,469,470],{"id":25,"depth":449,"text":26},{"id":63,"depth":449,"text":64},{"id":107,"depth":449,"text":108},{"id":150,"depth":449,"text":151},{"id":182,"depth":449,"text":183},{"id":221,"depth":449,"text":222},{"id":261,"depth":449,"text":262,"children":458},[459,461,462,463],{"id":266,"depth":460,"text":267},3,{"id":273,"depth":460,"text":274},{"id":280,"depth":460,"text":281},{"id":287,"depth":460,"text":288},{"id":294,"depth":449,"text":295},{"id":324,"depth":449,"text":325},{"id":357,"depth":449,"text":358},{"id":370,"depth":449,"text":371},{"id":409,"depth":449,"text":410},{"id":425,"depth":449,"text":426},{"id":437,"depth":449,"text":438},"tutorial","2026-08-29","Documenteer buiten- en binnenunit, bijverwarming, beveiligingen, leiding en fabrikantgegevens van een warmtepomp op het eendraadschema volgens AREI Boek 1 V06.","md","nl",{},true,"\u002Fblog\u002Fheat-pump-single-line-diagram.nl","10 min",12,{"title":5,"description":473},"warmtepomp-eendraadschema","blog\u002Fheat-pump-single-line-diagram.nl",[485,486,487,488,489,490,491],"Warmtepomp","Eendraadschema","AREI","Stroomkring","Buitenunit","Bijverwarming","België","Dmn4fw3pKfOe7RXJjrJY8xEsP0OwNoI_2_S5mgaVSBo",[494,952,1382,1812],{"id":495,"title":496,"articleId":6,"body":497,"category":471,"date":472,"description":937,"extension":474,"lastUpdated":472,"locale":938,"meta":939,"navigation":477,"path":940,"publishDate":472,"readTime":479,"refreshInterval":480,"seo":941,"slug":942,"stem":943,"tags":944,"__hash__":951},"blog\u002Fblog\u002Fheat-pump-single-line-diagram.de.md","Wärmepumpe im Eindrahtschema: Stromkreis und Angaben richtig darstellen",{"type":8,"value":498,"toc":916},[499,506,509,513,516,542,545,549,552,555,561,564,570,581,585,588,614,622,626,629,646,654,658,665,684,692,696,707,724,731,735,739,742,746,749,753,756,760,763,767,770,790,793,797,800,803,823,826,830,833,836,839,843,846,849,869,872,875,878,882,885,894,898,904,908],[11,500,501,502,505],{},"Eine Wärmepumpe ist im Eindrahtschema kein einzelnes Kästchen mit einer Leistungszahl. Je nach System gehören eine Außen- und Inneneinheit, ein elektrischer Heizstab, Pumpen, Regelung oder ein separater Warmwasserspeicher zur Anlage. Diese Teile können gemeinsam oder über mehrere Stromkreise versorgt werden. Das Schema muss die ",[15,503,504],{},"tatsächlich ausgeführte elektrische Struktur"," zeigen – nicht das vereinfachte Hydraulikschema aus dem Verkaufsprospekt.",[11,507,508],{},"AREI Buch 1 V06 schreibt nicht für jede Wärmepumpenmarke ein fertiges Standardsymbol oder einen universellen FI-Typ vor. Maßgeblich sind die allgemeinen Regeln für Stromkreise, Schutz, Leitungen und Dokumentation sowie die elektrischen Herstellerangaben des konkreten Geräts. Genau diese Trennung verhindert typische Fehler.",[23,510,512],{"id":511},"zuerst-die-elektrische-anlage-inventarisieren","Zuerst die elektrische Anlage inventarisieren",[11,514,515],{},"Beginnen Sie nicht mit dem Zeichnen, sondern mit Typenschildern, Datenblättern und dem Verteiler. Erfassen Sie für jede elektrisch versorgte Einheit:",[31,517,518,521,524,527,530,533,536,539],{},[34,519,520],{},"genaue Gerätebezeichnung und Funktion;",[34,522,523],{},"ein- oder dreiphasige Versorgung und Nennspannung;",[34,525,526],{},"Nennstrom beziehungsweise vom Hersteller verlangte Absicherung;",[34,528,529],{},"vorhandene Frequenzumrichter- oder Invertertechnik;",[34,531,532],{},"geforderten Fehlerstromschutz und mögliche Gleichfehlerstromanteile;",[34,534,535],{},"Kabeltyp, Leiterzahl, Querschnitt und Verlegeweg;",[34,537,538],{},"lokale Trenn- oder Wartungsschalter, sofern tatsächlich vorhanden;",[34,540,541],{},"separate elektrische Zusatzheizung, Kurbelgehäuseheizung, Umwälzpumpe oder Regelversorgung.",[11,543,544],{},"Ein Datenblatt mit „thermische Leistung 8 kW“ beantwortet diese Fragen nicht. Thermische Leistung, elektrische Aufnahmeleistung und Anschlusswert sind verschiedene Größen. Im Eindrahtschema zählt die elektrische Ausführung.",[23,546,548],{"id":547},"ein-gerät-oder-mehrere-stromkreise","Ein Gerät oder mehrere Stromkreise?",[11,550,551],{},"Bei einem kompakten Monoblock kann eine einzige Versorgung zur Außeneinheit führen. Eine Split-Anlage kann Außen- und Inneneinheit getrennt versorgen. Ein integrierter Heizstab kann über denselben Anschluss laufen oder einen eigenen, höher belasteten Stromkreis benötigen. Manche Regelungen werden aus der Inneneinheit gespeist, andere besitzen eine eigene Sicherung.",[11,553,554],{},"Zeichnen Sie daher nicht automatisch diese pauschale Kette:",[72,556,559],{"className":557,"code":558,"language":77,"meta":78},[75],"Verteiler → Automat → Wärmepumpe\n",[80,560,558],{"__ignoreMap":78},[11,562,563],{},"Eine reale Anlage kann beispielsweise so aufgebaut sein:",[72,565,568],{"className":566,"code":567,"language":77,"meta":78},[75],"Hauptverteiler\n├─ Stromkreis WP1 → Schutzgerät → Leitung → Außeneinheit\u002FInverter\n├─ Stromkreis WP2 → Schutzgerät → Leitung → Inneneinheit\u002FRegelung\n└─ Stromkreis WP3 → Schutzgerät → Leitung → elektrischer Zusatzheizer\n",[80,569,567],{"__ignoreMap":78},[11,571,572,573,96,575,577,578,580],{},"Die Bezeichnungen ",[80,574,95],{},[80,576,99],{}," und ",[80,579,103],{}," sind nur ein lesbares Beispiel. Verwenden Sie im Projekt die vorhandene Stromkreislogik und dieselben Referenzen im Situationsplan.",[23,582,584],{"id":583},"welche-angaben-gehören-an-den-abgang","Welche Angaben gehören an den Abgang?",[11,586,587],{},"Der Abgang sollte vom Verteiler bis zum Verbraucher nachvollziehbar sein. Dokumentieren Sie mindestens:",[113,589,590,593,596,599,602,605,608,611],{},[34,591,592],{},"Stromkreisreferenz;",[34,594,595],{},"Art, Polzahl und Bemessungsstrom des Überstromschutzes;",[34,597,598],{},"vorgeschalteten Fehlerstromschutz mit Bemessungsdifferenzstrom und Typ, wenn vorhanden;",[34,600,601],{},"Kabel- oder Leiterart, Leiterzahl und Querschnitt;",[34,603,604],{},"Phasenzuordnung bei mehrphasiger Versorgung;",[34,606,607],{},"eindeutige Gerätebezeichnung, etwa „Wärmepumpe Außeneinheit“;",[34,609,610],{},"relevante elektrische Leistung oder Nennstromangabe;",[34,612,613],{},"lokale Trennstelle, Schütz oder Lastmanagement-Komponente, sofern Teil der festen Installation.",[11,615,616,617,621],{},"Das ",[143,618,620],{"href":619},"\u002Fde\u002Fblog\u002Fkabelquerschnitt-sicherungsautomat","Verhältnis zwischen Kabelquerschnitt und Schutzorgan"," lässt sich nicht allein aus der Geräteleistung ableiten. Leitungslänge, Verlegeart, Häufung, Umgebungstemperatur, Spannungsfall, Kurzschlussbedingungen und Herstelleranforderungen bleiben Teil der Dimensionierung.",[23,623,625],{"id":624},"fircd-kein-universaltyp-für-jede-wärmepumpe","FI\u002FRCD: kein Universaltyp für jede Wärmepumpe",[11,627,628],{},"Wärmepumpen mit leistungselektronischem Verdichter können Fehlerströme mit anderen Wellenformen erzeugen als ein rein ohmscher Verbraucher. Daraus folgt aber nicht, dass jede Wärmepumpe pauschal einen Typ B benötigt oder dass Typ A immer ausreicht. Prüfen Sie:",[31,630,631,634,637,640,643],{},[34,632,633],{},"die verbindliche Installationsanleitung des exakten Modells;",[34,635,636],{},"ob eine Gleichfehlerstrom-Erkennung im Gerät vorhanden ist;",[34,638,639],{},"welche Schutzmaßnahme für den Netz- und Erdungstyp geplant ist;",[34,641,642],{},"Selektivität und Aufteilung zu vorgeschalteten RCDs;",[34,644,645],{},"unerwünschte Summen- und Ableitströme weiterer Verbraucher.",[11,647,648,649,653],{},"Der Artikel ",[143,650,652],{"href":651},"\u002Fde\u002Fblog\u002Ffi-typ-a-vs-typ-b","FI Typ A oder Typ B"," erklärt die Wellenformen und grenzt Hochimmunität, Selektivität und Fehlerstromtyp voneinander ab. Im Schema steht das tatsächlich eingebaute Schutzgerät, nicht eine Vermutung aus einer allgemeinen Tabelle.",[23,655,657],{"id":656},"symbol-und-legende-sauber-lösen","Symbol und Legende sauber lösen",[11,659,660,661,664],{},"Tabelle 2.23 von AREI Buch 1 V06 ist eine ",[15,662,663],{},"nicht erschöpfende"," Symbolübersicht. Fehlt für eine bestimmte Wärmepumpenkonfiguration ein eindeutiges Zeichen, darf eine verständliche Darstellung verwendet werden, wenn sie in der Legende definiert ist. Eine mögliche Dokumentation trennt beispielsweise:",[31,666,667,673,678],{},[34,668,669,672],{},[80,670,671],{},"WP-A",": Wärmepumpe Außeneinheit;",[34,674,675,677],{},[80,676,199],{},": Wärmepumpe Inneneinheit;",[34,679,680,683],{},[80,681,682],{},"ZH",": elektrischer Zusatzheizer.",[11,685,686,687,691],{},"Das Kürzel muss im gesamten Dossier gleich bleiben. Verwenden Sie es nicht gleichzeitig für eine Umwälzpumpe oder einen Heizkreis. Die ",[143,688,690],{"href":689},"\u002Fde\u002Fblog\u002Farei-elektrosymbole-uebersicht","AREI-Symbolübersicht"," zeigt, wann Standardzeichen genügen und wann eine projektspezifische Legende nötig ist.",[23,693,695],{"id":694},"eindrahtschema-und-situationsplan-synchron-halten","Eindrahtschema und Situationsplan synchron halten",[11,697,698,699,702,703,706],{},"Das Eindrahtschema beantwortet, ",[15,700,701],{},"wie"," die Wärmepumpe elektrisch angeschlossen und geschützt ist. Der Situationsplan zeigt, ",[15,704,705],{},"wo"," feste elektrische Betriebsmittel liegen. Verorten Sie dort je nach Projekt insbesondere:",[31,708,709,712,715,718,721],{},[34,710,711],{},"Außen- und Inneneinheit;",[34,713,714],{},"Wartungs- oder Trennschalter;",[34,716,717],{},"Unterverteiler oder Regelkasten;",[34,719,720],{},"festen Zusatzheizer;",[34,722,723],{},"relevante Leitungswege, wenn sie für die Lesbarkeit oder spätere Arbeiten wichtig sind.",[11,725,726,727,258],{},"Jede Position erhält dieselbe Stromkreisreferenz wie im Eindrahtschema. Ein Hydraulikplan kann das Dossier ergänzen, ersetzt die beiden elektrischen Pläne aber nicht. Mehr zur Rollenverteilung steht unter ",[143,728,730],{"href":729},"\u002Fde\u002Fblog\u002Feindrahtschema-vs-situationsplan","Eindrahtschema versus Situationsplan",[23,732,734],{"id":733},"häufige-dokumentationsfehler","Häufige Dokumentationsfehler",[264,736,738],{"id":737},"nur-wärmepumpe-8-kw-eintragen","Nur „Wärmepumpe 8 kW“ eintragen",[11,740,741],{},"Die Angabe verwechselt häufig thermische und elektrische Leistung. Schutzorgan, Versorgung und Leitung bleiben unklar.",[264,743,745],{"id":744},"zusatzheizung-übersehen","Zusatzheizung übersehen",[11,747,748],{},"Ein Heizstab kann die elektrische Spitzenlast deutlich verändern und einen eigenen Anschluss besitzen. Er muss erscheinen, wenn er Teil der festen Installation ist.",[264,750,752],{"id":751},"herstellerforderung-durch-faustregel-ersetzen","Herstellerforderung durch Faustregel ersetzen",[11,754,755],{},"Ein pauschaler RCD- oder Automatenvorschlag ist kein Ersatz für das konkrete Gerätedatenblatt und die vollständige Schutzplanung.",[264,757,759],{"id":758},"planungsstand-als-ist-zustand-ausgeben","Planungsstand als Ist-Zustand ausgeben",[11,761,762],{},"Leitungsweg, Phasen oder Geräteausführung können sich während der Montage ändern. Vor Abschluss müssen Schema, Beschriftung im Verteiler und Anlage vor Ort abgeglichen werden.",[23,764,766],{"id":765},"belastbare-abschlusskontrolle","Belastbare Abschlusskontrolle",[11,768,769],{},"Prüfen Sie vor der Übergabe:",[31,771,772,775,778,781,784,787],{},[34,773,774],{},"Stimmen Typenschild und Gerätebezeichnung mit dem Schema überein?",[34,776,777],{},"Sind Außen-, Innen- und Zusatzkomponenten vollständig erfasst?",[34,779,780],{},"Entsprechen Polzahl, Nennstrom und RCD-Angaben den eingebauten Geräten?",[34,782,783],{},"Sind Kabeldaten und Phasen nachvollziehbar?",[34,785,786],{},"Stimmen Stromkreisreferenzen in Eindrahtschema, Situationsplan und Verteiler überein?",[34,788,789],{},"Sind Herstellerunterlagen und spätere Änderungen im Installationsdossier abgelegt?",[11,791,792],{},"Diese Kontrolle ist eine Dokumentationsprüfung. Die vorgeschriebene Prüfung durch eine zugelassene Stelle und die fachgerechte elektrische Auslegung ersetzt sie nicht.",[23,794,796],{"id":795},"wann-das-schema-erneut-aktualisiert-werden-muss","Wann das Schema erneut aktualisiert werden muss",[11,798,799],{},"Nicht nur der Austausch der kompletten Wärmepumpe kann eine Dokumentationsänderung auslösen. Prüfen Sie den Plan auch, wenn ein Heizstab nachgerüstet, die Anschlussleistung freigeschaltet, ein einphasiges durch ein dreiphasiges Gerät ersetzt oder eine externe Steuerung fest eingebaut wird. Gleiches gilt, wenn ein Installateur den RCD, die Absicherung oder den Leitungsweg ändert.",[11,801,802],{},"Notieren Sie bei einer Änderung nicht einfach das neue Modell über das alte Symbol. Vergleichen Sie:",[31,804,805,808,811,814,817,820],{},[34,806,807],{},"alte und neue elektrische Anschlussdaten;",[34,809,810],{},"vorhandene Leitung und tatsächlich nutzbare Leiter;",[34,812,813],{},"Schutzgeräte und Herstelleranforderungen;",[34,815,816],{},"Phasenbelegung und Auswirkungen auf den Verteiler;",[34,818,819],{},"Positionen im Situationsplan;",[34,821,822],{},"Versionsdatum und zugehörige Geräteunterlagen.",[11,824,825],{},"Bleibt ein außer Betrieb genommener Stromkreis physisch vorhanden, muss die Dokumentation seinen wirklichen Zustand verständlich machen. Ein im Schema aktiver Verbraucher, der vor Ort abgeklemmt ist, ist ebenso irreführend wie eine neue Zusatzheizung, die im Plan fehlt.",[23,827,829],{"id":828},"praxisbeispiel-außengerät-inneneinheit-und-heizstab","Praxisbeispiel: Außengerät, Inneneinheit und Heizstab",[11,831,832],{},"Angenommen, eine Anlage besteht aus einem dreiphasig versorgten Außengerät, einer separat gespeisten Inneneinheit und einer elektrischen Zusatzheizung. Zeichnen Sie nicht vorschnell einen einzigen Block. Prüfen Sie am gelieferten Modell und an der Verdrahtung, ob drei Abgänge existieren oder ob Komponenten intern vom Außengerät versorgt werden. Nur tatsächlich getrennte Stromkreise erhalten eigene Schutzkette, Leitungsangaben und Referenz.",[11,834,835],{},"Für jeden vorhandenen Abgang erfassen Sie die elektrische Maximallast aus der verbindlichen Herstellerunterlage, nicht die thermische Heizleistung aus dem Prospekt. Ergänzen Sie Phasen, Neutralleiter und Schutzleiter entsprechend der realen Leitung. Ein dreiphasiges Außengerät kann daneben ein einphasiges Regel- oder Innenmodul besitzen; die gemeinsame Funktionsbezeichnung „Wärmepumpe“ macht diese Unterschiede nicht sichtbar. Der Heizstab ist besonders zu prüfen, weil seine Anschlussleistung und Schaltstufen die Wärmepumpenangabe deutlich übersteigen können.",[11,837,838],{},"Auf dem Situationsplan stehen Außengerät, Inneneinheit, fester Trennpunkt und gegebenenfalls separat gespeister Heizstab an ihren tatsächlichen Orten. Steuer-, Bus- oder Fühlerleitungen werden nicht als Leistungsstromkreis ausgegeben. Sind sie für Wartung wichtig, beschreiben Sie sie in Legende oder Herstellerdokumentation eindeutig, ohne sie mit der Netzversorgung zu vermischen.",[23,840,842],{"id":841},"inbetriebnahmedaten-und-betriebsarten-berücksichtigen","Inbetriebnahmedaten und Betriebsarten berücksichtigen",[11,844,845],{},"Vergleichen Sie den gezeichneten Abgang nach der Inbetriebnahme mit Typenschild, Anschlussklemmen, Installateurmenü und Prüfprotokoll. Lastbegrenzung, Sperrkontakt oder Energiemanagement können den Betrieb beeinflussen, ersetzen aber nicht automatisch die erforderliche Dimensionierung und Schutzbewertung. Dokumentieren Sie nur Einstellungen, die tatsächlich gesetzt, gegen unbeabsichtigte Änderung gesichert und für die Auslegung relevant sind.",[11,847,848],{},"Prüfen Sie außerdem Betriebsfälle, die im Normalbetrieb leicht übersehen werden:",[31,850,851,854,857,860,863,866],{},[34,852,853],{},"Abtauvorgang und gleichzeitige Zusatzheizung;",[34,855,856],{},"Not- oder Legionellenbetrieb mit elektrischem Heizstab;",[34,858,859],{},"Anlauf- und Umrichterverhalten gemäß Herstellerangabe;",[34,861,862],{},"getrennte Versorgung von Kondensatwannenheizung oder Begleitheizung;",[34,864,865],{},"Abschaltung und sicheres Trennen bei Wartung;",[34,867,868],{},"Wiederanlauf nach Netzunterbrechung oder Lastabwurf.",[11,870,871],{},"Diese Liste bestimmt nicht pauschal Schutzorgan oder Querschnitt. Sie zeigt, welche Eingangsdaten Elektroplaner und Herstellerunterlagen klären müssen. Messwerte und Abschaltbedingungen bleiben Teil der fachlichen Prüfung vor Ort.",[11,873,874],{},"Erfassen Sie außerdem, welche Komponente bei abgeschaltetem Hauptabgang weiterhin Spannung führen kann. Manche Regelungen, Kommunikationsnetzteile oder Zusatzgeräte besitzen eine andere Versorgung. Eine Wartungsskizze darf diese Hilfsversorgung nicht verschweigen. Kennzeichnen Sie Trennstellen nur dann als gemeinsam wirksam, wenn Verdrahtung und Herstellerkonzept das bestätigen. So verhindert die Dokumentation, dass eine vermeintlich vollständig abgeschaltete Anlage noch aus einem zweiten Abgang gespeist wird.",[11,876,877],{},"Übernehmen Sie diese Trennung in die Beschriftung des Verteilers. Ein Sammelbegriff für mehrere Abgänge erschwert Wartung und Vergleich mit dem Plan. Verwenden Sie kurze, eindeutige Funktionsnamen und dieselben Referenzen auf Schema, Situationsplan und Gerät. Prüfen Sie nach dem Beschriften durch gezieltes Freischalten, ob jede Kennzeichnung tatsächlich den erwarteten Anlagenteil betrifft. Das Ergebnis gehört zum as-built Abgleich, nicht zu einer ungeprüften Planannahme.",[23,879,881],{"id":880},"schnittstellen-zu-pv-batterie-und-lastmanagement","Schnittstellen zu PV, Batterie und Lastmanagement",[11,883,884],{},"Eine Wärmepumpe kann auf Eigenverbrauchssteuerung reagieren, bleibt dadurch aber kein PV-Verbraucher „hinter dem Wechselrichter“, wenn die reale AC-Topologie anders aufgebaut ist. Zeichnen Sie Energiepfade so, wie sie elektrisch verbunden sind. Kommunikationskontakte oder Smart-Grid-Signale werden getrennt erläutert. Bei Ersatzstrom ist zusätzlich zu klären, ob die Wärmepumpe überhaupt vom Ersatzstromverteiler versorgt wird und welche Anlauf- und Leistungsgrenzen gelten; eine bloße App-Einstellung beweist das nicht.",[11,886,887,888,893],{},"Die ",[143,889,892],{"href":890,"rel":891},"https:\u002F\u002Feconomie.fgov.be\u002Fde\u002Fpublication\u002Fallgemeine-vorschriften-fuer",[420],"amtliche Veröffentlichung von AREI Buch 1"," liefert die allgemeine Plan- und Schutzgrundlage. Modellbezogene Anschlusswerte, vorgeschriebene externe Schutzmaßnahmen und Anschlussvarianten stammen aus der aktuellen Anleitung des tatsächlich eingebauten Geräts.",[23,895,897],{"id":896},"mit-planelec-dokumentieren","Mit PlanElec dokumentieren",[11,899,174,900,903],{},[143,901,433],{"href":902},"\u002Fde\u002F"," können Sie die Wärmepumpenkomponenten den tatsächlichen Stromkreisen zuordnen, Schutz- und Leitungsangaben erfassen und Eindrahtschema sowie Situationsplan als PDF ausgeben. Für projektspezifische Zeichen bleibt eine verständliche Legende wichtig. Der orientierende Selbstcheck kann unterstützte Eingaben auf Auffälligkeiten prüfen; er bestätigt weder AREI-Konformität noch Herstellerfreigabe und erzeugt keinen offiziellen Prüfbericht.",[23,905,907],{"id":906},"quellenstand","Quellenstand",[11,909,910,911,915],{},"Fachliche Basis sind die amtliche Veröffentlichung von ",[143,912,914],{"href":444,"rel":913},[420],"AREI\u002FRGIE Buch 1",", insbesondere Teil 2 Tabelle 2.23 und Teil 3 zu Inhalt und Referenzen der Pläne, sowie die elektrische Installationsanleitung des konkreten Wärmepumpenherstellers. Geprüfter Stand dieses Artikels: Buch 1 V06, 29.08.2026.",{"title":78,"searchDepth":449,"depth":449,"links":917},[918,919,920,921,922,923,924,930,931,932,933,934,935,936],{"id":511,"depth":449,"text":512},{"id":547,"depth":449,"text":548},{"id":583,"depth":449,"text":584},{"id":624,"depth":449,"text":625},{"id":656,"depth":449,"text":657},{"id":694,"depth":449,"text":695},{"id":733,"depth":449,"text":734,"children":925},[926,927,928,929],{"id":737,"depth":460,"text":738},{"id":744,"depth":460,"text":745},{"id":751,"depth":460,"text":752},{"id":758,"depth":460,"text":759},{"id":765,"depth":449,"text":766},{"id":795,"depth":449,"text":796},{"id":828,"depth":449,"text":829},{"id":841,"depth":449,"text":842},{"id":880,"depth":449,"text":881},{"id":896,"depth":449,"text":897},{"id":906,"depth":449,"text":907},"So dokumentieren Sie Außen- und Inneneinheit, Zusatzheizung, Schutzgeräte, Leitung und Herstellerangaben einer Wärmepumpe im Eindrahtschema nach AREI Buch 1 V06.","de",{},"\u002Fblog\u002Fheat-pump-single-line-diagram.de",{"title":496,"description":937},"waermepumpe-eindrahtschema","blog\u002Fheat-pump-single-line-diagram.de",[945,946,487,947,948,949,950],"Wärmepumpe","Eindrahtschema","Stromkreis","Außeneinheit","Zusatzheizung","Belgien","ZVnI--xcBxulN3N5Shz8KzbiE2yNG_D-hg7ABBnIRJE",{"id":953,"title":954,"articleId":6,"body":955,"category":471,"date":472,"description":1368,"extension":474,"lastUpdated":472,"locale":1369,"meta":1370,"navigation":477,"path":1371,"publishDate":472,"readTime":479,"refreshInterval":480,"seo":1372,"slug":6,"stem":1373,"tags":1374,"__hash__":1381},"blog\u002Fblog\u002Fheat-pump-single-line-diagram.en.md","Heat Pump on a Single-Line Diagram: Showing the Circuit and Equipment Correctly",{"type":8,"value":956,"toc":1347},[957,964,967,971,974,1000,1003,1007,1010,1013,1019,1022,1028,1041,1045,1048,1074,1082,1086,1089,1106,1114,1118,1121,1141,1153,1157,1168,1185,1193,1197,1201,1204,1208,1211,1215,1218,1222,1225,1229,1232,1252,1255,1259,1262,1265,1269,1272,1275,1278,1282,1285,1288,1308,1311,1315,1318,1325,1329,1335,1339],[11,958,959,960,963],{},"Electrically, a heat pump is often more than one appliance. An outdoor unit, indoor module, backup resistance heater, circulation pump, controller and hot-water cylinder may use separate supplies. Other systems combine several functions behind one connection. The single-line diagram must show the ",[15,961,962],{},"electrical installation as actually built",", not the simplified hydraulic drawing in a sales brochure.",[11,965,966],{},"AREI Book 1 V06 does not assign one universal heat-pump symbol, breaker or RCD type to every make and model. General requirements for circuits, protection, conductors and documentation apply together with the electrical instructions for the exact equipment. A dependable drawing starts by distinguishing those sources.",[23,968,970],{"id":969},"collect-the-electrical-evidence-first","Collect the electrical evidence first",[11,972,973],{},"Before drawing, inspect the distribution board, nameplates and installation manuals. Record for every electrically supplied component:",[31,975,976,979,982,985,988,991,994,997],{},[34,977,978],{},"exact equipment reference and function;",[34,980,981],{},"voltage and single- or three-phase supply;",[34,983,984],{},"rated current and the maximum protective device specified by the manufacturer;",[34,986,987],{},"inverter or variable-speed drive technology;",[34,989,990],{},"RCD instructions and information about possible smooth-DC residual currents;",[34,992,993],{},"cable type, conductor count, cross-section and actual route;",[34,995,996],{},"local isolator or maintenance switch where installed;",[34,998,999],{},"separate supplies for backup heat, controls, pumps or the cylinder.",[11,1001,1002],{},"A label stating “8 kW heating output” does not give the electrical input or connection rating. Thermal output and electrical demand are different values. Only the relevant electrical value belongs beside the circuit.",[23,1004,1006],{"id":1005},"decide-how-many-circuits-really-exist","Decide how many circuits really exist",[11,1008,1009],{},"A monobloc unit may have one supply. A split system may feed outdoor and indoor units separately. A built-in resistance heater may share a terminal block or require a distinct, higher-current branch. Controls may be powered from the indoor unit or from their own protected supply.",[11,1011,1012],{},"Do not automatically draw this simplified chain:",[72,1014,1017],{"className":1015,"code":1016,"language":77,"meta":78},[75],"Distribution board → breaker → heat pump\n",[80,1018,1016],{"__ignoreMap":78},[11,1020,1021],{},"An installed arrangement could instead be:",[72,1023,1026],{"className":1024,"code":1025,"language":77,"meta":78},[75],"Main distribution board\n├─ circuit HP1 → protection → cable → outdoor unit\u002Finverter\n├─ circuit HP2 → protection → cable → indoor unit\u002Fcontroller\n└─ circuit HP3 → protection → cable → electric backup heater\n",[80,1027,1025],{"__ignoreMap":78},[11,1029,1030,96,1033,1036,1037,1040],{},[80,1031,1032],{},"HP1",[80,1034,1035],{},"HP2"," and ",[80,1038,1039],{},"HP3"," are examples only. Follow the project’s circuit lettering and repeat exactly the same references on the situation plan.",[23,1042,1044],{"id":1043},"what-to-show-on-each-branch","What to show on each branch",[11,1046,1047],{},"The path from board to load should be understandable without assumptions. Include at least:",[113,1049,1050,1053,1056,1059,1062,1065,1068,1071],{},[34,1051,1052],{},"circuit reference;",[34,1054,1055],{},"overcurrent-device type, pole count and rating;",[34,1057,1058],{},"upstream RCD rating and type where present;",[34,1060,1061],{},"cable or conductor type, conductor count and cross-section;",[34,1063,1064],{},"phase allocation for a multiphase supply;",[34,1066,1067],{},"an unambiguous label such as “heat pump outdoor unit”;",[34,1069,1070],{},"relevant electrical power or rated current;",[34,1072,1073],{},"a fixed isolator, contactor or load-control device when it is part of the installation.",[11,1075,1076,1077,1081],{},"The ",[143,1078,1080],{"href":1079},"\u002Fen\u002Fblog\u002Fcable-cross-section-breaker","relationship between cable cross-section and breaker"," cannot be derived from appliance power alone. Route length, installation method, grouping, ambient temperature, voltage drop, prospective fault current and manufacturer limits remain part of the full design.",[23,1083,1085],{"id":1084},"rcd-selection-is-model-specific","RCD selection is model-specific",[11,1087,1088],{},"Power electronics driving a compressor can produce residual-current waveforms unlike those of a purely resistive load. That does not make Type B mandatory for every heat pump, nor does it mean Type A is always sufficient. Check together:",[31,1090,1091,1094,1097,1100,1103],{},[34,1092,1093],{},"the binding instructions for the exact model and installed options;",[34,1095,1096],{},"any integrated smooth-DC residual-current detection;",[34,1098,1099],{},"the earthing arrangement and planned disconnection conditions;",[34,1101,1102],{},"selectivity and division between upstream RCDs;",[34,1104,1105],{},"cumulative leakage from other connected equipment.",[11,1107,1108,1109,1113],{},"The guide to ",[143,1110,1112],{"href":1111},"\u002Fen\u002Fblog\u002Frcd-type-a-vs-b","RCD Type A versus Type B"," separates waveform capability, high immunity and time selectivity. The diagram must state what is installed, rather than repeating a generic table.",[23,1115,1117],{"id":1116},"use-a-clear-symbol-and-legend","Use a clear symbol and legend",[11,1119,1120],{},"Table 2.23 of AREI Book 1 V06 is non-exhaustive. If no standard symbol clearly describes the installed heat-pump arrangement, an unambiguous project symbol may be used when its meaning is defined in the legend. For example:",[31,1122,1123,1129,1135],{},[34,1124,1125,1128],{},[80,1126,1127],{},"HP-O",": heat-pump outdoor unit;",[34,1130,1131,1134],{},[80,1132,1133],{},"HP-I",": heat-pump indoor unit;",[34,1136,1137,1140],{},[80,1138,1139],{},"BH",": electric backup heater.",[11,1142,1143,1144,1147,1148,1152],{},"Keep each abbreviation consistent throughout the dossier. Do not reuse ",[80,1145,1146],{},"HP"," for a hydraulic pump elsewhere. The ",[143,1149,1151],{"href":1150},"\u002Fen\u002Fblog\u002Farei-electrical-symbols-overview","AREI electrical-symbol overview"," explains when a project legend is appropriate.",[23,1154,1156],{"id":1155},"keep-the-situation-plan-aligned","Keep the situation plan aligned",[11,1158,1159,1160,1163,1164,1167],{},"The single-line diagram explains ",[15,1161,1162],{},"how"," the heat pump is supplied and protected. The situation plan identifies ",[15,1165,1166],{},"where"," fixed electrical equipment is located. Depending on the installation, place:",[31,1169,1170,1173,1176,1179,1182],{},[34,1171,1172],{},"outdoor and indoor units;",[34,1174,1175],{},"a maintenance switch or local isolator;",[34,1177,1178],{},"a control cabinet or sub-board;",[34,1180,1181],{},"the fixed electric backup heater;",[34,1183,1184],{},"important fixed cable routes when needed for safe future work.",[11,1186,1187,1188,1192],{},"Every location must use the same circuit reference as the single-line diagram. A hydraulic schematic can supplement the dossier but cannot replace the electrical plans. See ",[143,1189,1191],{"href":1190},"\u002Fen\u002Fblog\u002Fsingle-line-diagram-vs-situation-plan","single-line diagram versus situation plan"," for the division of roles.",[23,1194,1196],{"id":1195},"common-documentation-failures","Common documentation failures",[264,1198,1200],{"id":1199},"showing-only-8-kw-heat-pump","Showing only “8 kW heat pump”",[11,1202,1203],{},"That figure is commonly thermal output. It leaves the electrical supply, protection and wiring unknown.",[264,1205,1207],{"id":1206},"omitting-backup-heat","Omitting backup heat",[11,1209,1210],{},"A resistance heater can materially increase peak demand and may have its own connection. Show it whenever it forms part of the fixed electrical installation.",[264,1212,1214],{"id":1213},"copying-another-models-protection","Copying another model’s protection",[11,1216,1217],{},"Similar thermal ratings do not imply identical supply, RCD or breaker requirements. Use the actual manual and design calculations.",[264,1219,1221],{"id":1220},"treating-design-intent-as-as-built-information","Treating design intent as as-built information",[11,1223,1224],{},"Phases, options and routes can change during installation. Reconcile the drawing, board labels and equipment on site before completing the dossier.",[23,1226,1228],{"id":1227},"final-document-review","Final document review",[11,1230,1231],{},"Before handover, confirm that:",[31,1233,1234,1237,1240,1243,1246,1249],{},[34,1235,1236],{},"equipment labels match the nameplates;",[34,1238,1239],{},"outdoor, indoor and auxiliary supplies are all represented;",[34,1241,1242],{},"pole counts, ratings and RCD details match installed devices;",[34,1244,1245],{},"conductor and phase information is traceable;",[34,1247,1248],{},"circuit references agree across board, single-line diagram and situation plan;",[34,1250,1251],{},"manufacturer instructions and later changes remain in the installation dossier.",[11,1253,1254],{},"This is a documentation review. It does not replace electrical design, competent installation or the required inspection by a recognised inspection body.",[23,1256,1258],{"id":1257},"when-the-diagram-needs-another-revision","When the diagram needs another revision",[11,1260,1261],{},"Review the documents not only after replacing the complete heat pump, but also when enabling a backup heater, changing available electrical power, moving from single- to three-phase equipment or adding a permanently wired controller. A changed RCD, breaker, cable route or phase allocation must also reach the as-built version.",[11,1263,1264],{},"Compare old and new connection data, available conductors, protection, manufacturer requirements, situation-plan locations and supporting manuals. If a disconnected circuit remains physically present, show its real status clearly. A drawing that still presents an isolated appliance as active is as misleading as one that omits a newly connected resistance heater.",[23,1266,1268],{"id":1267},"worked-example-outdoor-unit-indoor-module-and-backup-heater","Worked example: outdoor unit, indoor module and backup heater",[11,1270,1271],{},"Assume an installation has a three-phase outdoor unit, a separately supplied indoor module and electrical backup heat. Do not immediately reduce it to one block. Check the delivered model and site wiring to determine whether there are three final circuits or whether some components are supplied internally by the outdoor unit. Only genuinely separate circuits receive their own protective chain, wiring data and reference.",[11,1273,1274],{},"For each real branch, record maximum electrical input from the authoritative manufacturer documentation, not thermal output from a sales sheet. Show phases, neutral and protective conductor according to the installed cable. A three-phase outdoor unit may sit beside a single-phase controller or indoor module; the common function “heat pump” does not make those differences disappear. Review the backup heater especially carefully because its connected load and stages can exceed the compressor input by a wide margin.",[11,1276,1277],{},"Locate the outdoor unit, indoor module, fixed means of isolation and any separately supplied heater at their actual positions on the position plan. Do not present control, bus or sensor wiring as a power circuit. Where it matters for maintenance, explain it in the legend or technical documentation without mixing it with the mains supply.",[23,1279,1281],{"id":1280},"account-for-commissioning-settings-and-operating-modes","Account for commissioning settings and operating modes",[11,1283,1284],{},"After commissioning, compare the drawn branch with nameplates, terminals, installer settings and test records. Load limiting, inhibit contacts and energy management may affect operation, but they do not automatically replace competent sizing and protective-device assessment. Record only settings that were actually applied, protected against unintended change and relevant to the design basis.",[11,1286,1287],{},"Review operating cases that a normal heating cycle can hide:",[31,1289,1290,1293,1296,1299,1302,1305],{},[34,1291,1292],{},"defrost with simultaneous backup heat;",[34,1294,1295],{},"emergency or hygiene cycle using the electric heater;",[34,1297,1298],{},"starting and inverter behaviour stated by the manufacturer;",[34,1300,1301],{},"separate supply for tray or trace heating;",[34,1303,1304],{},"safe isolation for maintenance;",[34,1306,1307],{},"restart following a supply interruption or load-shedding event.",[11,1309,1310],{},"This list does not prescribe one breaker, RCD or cable size. It identifies inputs the electrical designer must settle against the exact instructions and installation conditions. Measurements and disconnection performance remain on-site verification matters.",[23,1312,1314],{"id":1313},"interfaces-with-pv-storage-and-load-management","Interfaces with PV, storage and load management",[11,1316,1317],{},"A heat pump may respond to self-consumption control, but that does not place it electrically “behind the PV inverter” when the AC topology says otherwise. Draw energy paths according to the real connections and explain communications or smart-grid contacts separately. For backup power, establish whether the heat pump is actually supplied by the backup board and whether starting and power limits permit that mode. A setting visible in an app is not evidence of the wiring arrangement.",[11,1319,1076,1320,1324],{},[143,1321,1323],{"href":444,"rel":1322},[420],"official AREI\u002FRGIE Book 1 publication"," provides the general diagram and safety framework. Model-specific input values, external protection requirements and connection variants come from the current instructions for the exact installed equipment.",[23,1326,1328],{"id":1327},"documenting-the-system-in-planelec","Documenting the system in PlanElec",[11,1330,174,1331,1334],{},[143,1332,433],{"href":1333},"\u002Fen\u002F",", you can assign heat-pump components to the circuits actually installed, record protection and conductor details, and export the single-line diagram and situation plan as PDFs. Project-specific symbols still require a clear legend. The indicative self-check can flag supported data, but it does not certify AREI compliance, approve the manufacturer design or create an official inspection report.",[23,1336,1338],{"id":1337},"sources-and-reviewed-version","Sources and reviewed version",[11,1340,1341,1342,1346],{},"The regulatory basis is the official ",[143,1343,1345],{"href":444,"rel":1344},[420],"AREI\u002FRGIE Book 1 publication",", particularly Table 2.23 and Part 3 on electrical plans, together with the electrical installation manual for the exact heat-pump model. Reviewed against Book 1 V06 on 29 August 2026.",{"title":78,"searchDepth":449,"depth":449,"links":1348},[1349,1350,1351,1352,1353,1354,1355,1361,1362,1363,1364,1365,1366,1367],{"id":969,"depth":449,"text":970},{"id":1005,"depth":449,"text":1006},{"id":1043,"depth":449,"text":1044},{"id":1084,"depth":449,"text":1085},{"id":1116,"depth":449,"text":1117},{"id":1155,"depth":449,"text":1156},{"id":1195,"depth":449,"text":1196,"children":1356},[1357,1358,1359,1360],{"id":1199,"depth":460,"text":1200},{"id":1206,"depth":460,"text":1207},{"id":1213,"depth":460,"text":1214},{"id":1220,"depth":460,"text":1221},{"id":1227,"depth":449,"text":1228},{"id":1257,"depth":449,"text":1258},{"id":1267,"depth":449,"text":1268},{"id":1280,"depth":449,"text":1281},{"id":1313,"depth":449,"text":1314},{"id":1327,"depth":449,"text":1328},{"id":1337,"depth":449,"text":1338},"Document the outdoor unit, indoor unit, backup heater, protection, cable and manufacturer data of a heat pump under AREI Book 1 V06.","en",{},"\u002Fblog\u002Fheat-pump-single-line-diagram.en",{"title":954,"description":1368},"blog\u002Fheat-pump-single-line-diagram.en",[1375,1376,487,1377,1378,1379,1380],"Heat pump","Single-line diagram","Circuit","Outdoor unit","Backup heater","Belgium","vCdies-pNOH9Ahq9i2TKMHEh_tDplz85BO3_C144bHI",{"id":1383,"title":1384,"articleId":6,"body":1385,"category":471,"date":472,"description":1797,"extension":474,"lastUpdated":472,"locale":1798,"meta":1799,"navigation":477,"path":1800,"publishDate":472,"readTime":479,"refreshInterval":480,"seo":1801,"slug":1802,"stem":1803,"tags":1804,"__hash__":1811},"blog\u002Fblog\u002Fheat-pump-single-line-diagram.fr.md","Pompe à chaleur sur le schéma unifilaire : circuit et données à représenter",{"type":8,"value":1386,"toc":1776},[1387,1394,1397,1401,1404,1430,1433,1437,1440,1443,1449,1452,1458,1472,1476,1479,1505,1513,1517,1520,1537,1545,1549,1552,1572,1580,1584,1595,1612,1620,1624,1628,1631,1635,1638,1642,1645,1649,1652,1656,1659,1679,1682,1686,1689,1692,1696,1699,1702,1705,1709,1712,1715,1735,1738,1742,1745,1753,1757,1764,1768],[11,1388,1389,1390,1393],{},"Une pompe à chaleur ne se résume pas toujours à un seul récepteur. Une unité extérieure, un module intérieur, une résistance d’appoint, des circulateurs, une régulation ou un ballon sanitaire peuvent recevoir des alimentations différentes. Le schéma unifilaire doit décrire cette ",[15,1391,1392],{},"architecture électrique réellement installée",", et non le dessin hydraulique simplifié d’une brochure.",[11,1395,1396],{},"Le RGIE Livre 1 V06 ne prescrit pas un symbole, un disjoncteur ou un type de différentiel unique pour toutes les pompes à chaleur. Les règles générales relatives aux circuits, aux protections, aux canalisations et aux documents s’appliquent avec les instructions électriques du modèle exact. La qualité du schéma dépend donc d’un relevé précis.",[23,1398,1400],{"id":1399},"réunir-les-données-avant-de-dessiner","Réunir les données avant de dessiner",[11,1402,1403],{},"Examinez le tableau, les plaques signalétiques et les notices d’installation. Pour chaque élément alimenté, relevez :",[31,1405,1406,1409,1412,1415,1418,1421,1424,1427],{},[34,1407,1408],{},"la référence et la fonction de l’appareil ;",[34,1410,1411],{},"la tension et le raccordement monophasé ou triphasé ;",[34,1413,1414],{},"le courant nominal et la protection maximale demandée par le constructeur ;",[34,1416,1417],{},"la présence d’un variateur ou d’une électronique inverter ;",[34,1419,1420],{},"les indications relatives au différentiel et aux composantes continues possibles ;",[34,1422,1423],{},"le type de câble, le nombre de conducteurs, la section et le trajet réel ;",[34,1425,1426],{},"l’éventuel interrupteur de proximité ou dispositif de sectionnement ;",[34,1428,1429],{},"les alimentations séparées de l’appoint, de la régulation, d’une pompe ou du ballon.",[11,1431,1432],{},"Une puissance thermique de 8 kW n’est ni la puissance électrique absorbée ni la puissance de raccordement. Le document électrique doit reprendre les grandeurs électriques pertinentes.",[23,1434,1436],{"id":1435},"déterminer-le-nombre-réel-de-circuits","Déterminer le nombre réel de circuits",[11,1438,1439],{},"Un monobloc peut disposer d’une seule alimentation. Un système split peut alimenter séparément les unités extérieure et intérieure. Une résistance intégrée peut partager le bornier principal ou dépendre d’un départ distinct. La commande peut être alimentée par le module intérieur ou par sa propre protection.",[11,1441,1442],{},"Évitez donc de recopier systématiquement :",[72,1444,1447],{"className":1445,"code":1446,"language":77,"meta":78},[75],"Tableau → disjoncteur → pompe à chaleur\n",[80,1448,1446],{"__ignoreMap":78},[11,1450,1451],{},"Une réalisation peut plutôt présenter cette structure :",[72,1453,1456],{"className":1454,"code":1455,"language":77,"meta":78},[75],"Tableau principal\n├─ circuit PAC1 → protection → câble → unité extérieure\u002Finverter\n├─ circuit PAC2 → protection → câble → unité intérieure\u002Frégulation\n└─ circuit PAC3 → protection → câble → appoint électrique\n",[80,1457,1455],{"__ignoreMap":78},[11,1459,1460,1461,96,1464,1467,1468,1471],{},"Les repères ",[80,1462,1463],{},"PAC1",[80,1465,1466],{},"PAC2"," et ",[80,1469,1470],{},"PAC3"," sont des exemples. Utilisez les lettres de circuit du projet et conservez-les sur le plan de situation.",[23,1473,1475],{"id":1474},"informations-à-placer-sur-chaque-départ","Informations à placer sur chaque départ",[11,1477,1478],{},"La chaîne entre le tableau et le récepteur doit pouvoir être relue sans deviner. Indiquez au minimum :",[113,1480,1481,1484,1487,1490,1493,1496,1499,1502],{},[34,1482,1483],{},"le repère du circuit ;",[34,1485,1486],{},"le type, le nombre de pôles et le courant assigné de la protection contre les surintensités ;",[34,1488,1489],{},"le différentiel présent, avec sensibilité et type ;",[34,1491,1492],{},"le type de câble ou de conducteur, leur nombre et leur section ;",[34,1494,1495],{},"l’affectation des phases pour une alimentation polyphasée ;",[34,1497,1498],{},"une désignation précise, telle que « pompe à chaleur – unité extérieure » ;",[34,1500,1501],{},"la puissance électrique ou le courant nominal utile ;",[34,1503,1504],{},"le sectionneur, contacteur ou dispositif de gestion de puissance s’il fait partie de l’installation fixe.",[11,1506,1507,1508,1512],{},"Le choix de la ",[143,1509,1511],{"href":1510},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","section de câble et du disjoncteur"," exige davantage que la puissance nominale. Longueur, mode de pose, groupement, température, chute de tension, courant de court-circuit et notice constructeur interviennent dans le dimensionnement complet.",[23,1514,1516],{"id":1515},"différentiel-partir-du-modèle-réel","Différentiel : partir du modèle réel",[11,1518,1519],{},"L’électronique de puissance du compresseur peut produire des formes de courant de défaut différentes de celles d’une charge résistive. Cela ne signifie ni qu’un type B est toujours obligatoire, ni qu’un type A convient toujours. Vérifiez ensemble :",[31,1521,1522,1525,1528,1531,1534],{},[34,1523,1524],{},"la notice obligatoire du modèle et de ses options ;",[34,1526,1527],{},"la présence éventuelle d’une détection interne du courant continu résiduel ;",[34,1529,1530],{},"le schéma de mise à la terre et les conditions de coupure ;",[34,1532,1533],{},"la sélectivité avec les différentiels placés en amont ;",[34,1535,1536],{},"les courants de fuite cumulés des autres équipements.",[11,1538,1539,1540,1544],{},"Le guide ",[143,1541,1543],{"href":1542},"\u002Ffr\u002Fblog\u002Fdifferentiel-type-a-vs-type-b","différentiel type A ou type B"," sépare forme d’onde, immunité renforcée et sélectivité. Le schéma doit représenter l’appareil installé et ses caractéristiques, pas une recommandation générique.",[23,1546,1548],{"id":1547},"choisir-un-symbole-et-définir-la-légende","Choisir un symbole et définir la légende",[11,1550,1551],{},"Le tableau 2.23 du RGIE Livre 1 V06 n’est pas exhaustif. Lorsqu’aucun symbole standard n’exprime clairement la configuration, un signe non ambigu peut être utilisé à condition d’être défini dans la légende. Par exemple :",[31,1553,1554,1560,1566],{},[34,1555,1556,1559],{},[80,1557,1558],{},"PAC-E"," : unité extérieure ;",[34,1561,1562,1565],{},[80,1563,1564],{},"PAC-I"," : unité intérieure ;",[34,1567,1568,1571],{},[80,1569,1570],{},"AE"," : appoint électrique.",[11,1573,1574,1575,1579],{},"La signification doit rester identique dans tout le dossier. Ne réutilisez pas la même abréviation pour une pompe de circulation. La page ",[143,1576,1578],{"href":1577},"\u002Ffr\u002Fblog\u002Fsymboles-electriques-rgie","symboles électriques du RGIE"," détaille la règle de légende.",[23,1581,1583],{"id":1582},"relier-unifilaire-et-plan-de-situation","Relier unifilaire et plan de situation",[11,1585,1586,1587,1590,1591,1594],{},"Le schéma unifilaire explique ",[15,1588,1589],{},"comment"," la pompe à chaleur est alimentée et protégée. Le plan de situation indique ",[15,1592,1593],{},"où"," se trouvent les équipements électriques fixes. Selon le chantier, localisez :",[31,1596,1597,1600,1603,1606,1609],{},[34,1598,1599],{},"les unités extérieure et intérieure ;",[34,1601,1602],{},"l’interrupteur de proximité ou le sectionneur ;",[34,1604,1605],{},"le coffret de commande ou le tableau secondaire ;",[34,1607,1608],{},"la résistance d’appoint fixe ;",[34,1610,1611],{},"les cheminements fixes utiles à la compréhension ou à la maintenance.",[11,1613,1614,1615,1619],{},"Chaque élément reprend le même repère de circuit que sur l’unifilaire. Un schéma hydraulique peut compléter le dossier mais ne remplace pas les plans électriques. Consultez ",[143,1616,1618],{"href":1617},"\u002Ffr\u002Fblog\u002Fschema-unifilaire-vs-plan-situation","schéma unifilaire ou plan de situation"," pour leur articulation.",[23,1621,1623],{"id":1622},"erreurs-fréquentes","Erreurs fréquentes",[264,1625,1627],{"id":1626},"écrire-seulement-pac-8-kw","Écrire seulement « PAC 8 kW »",[11,1629,1630],{},"Cette valeur est souvent thermique. Elle ne renseigne ni l’alimentation, ni la protection, ni la canalisation électrique.",[264,1632,1634],{"id":1633},"oublier-lappoint-électrique","Oublier l’appoint électrique",[11,1636,1637],{},"Une résistance peut modifier fortement la pointe électrique et disposer d’un départ propre. Elle doit apparaître lorsqu’elle appartient à l’installation fixe.",[264,1639,1641],{"id":1640},"copier-la-protection-dun-autre-modèle","Copier la protection d’un autre modèle",[11,1643,1644],{},"Deux appareils de puissance thermique comparable peuvent avoir une alimentation et des exigences différentielles différentes.",[264,1646,1648],{"id":1647},"livrer-le-projet-au-lieu-de-las-built","Livrer le projet au lieu de l’as-built",[11,1650,1651],{},"Les phases, options et trajets peuvent évoluer sur chantier. Le schéma, les étiquettes du tableau et le dossier doivent être réconciliés après la pose.",[23,1653,1655],{"id":1654},"vérification-documentaire-finale","Vérification documentaire finale",[11,1657,1658],{},"Avant la remise du dossier, vérifiez :",[31,1660,1661,1664,1667,1670,1673,1676],{},[34,1662,1663],{},"concordance entre plaques signalétiques et noms du schéma ;",[34,1665,1666],{},"présence de toutes les unités et alimentations auxiliaires ;",[34,1668,1669],{},"correspondance des pôles, calibres et différentiels avec le matériel posé ;",[34,1671,1672],{},"traçabilité des câbles et des phases ;",[34,1674,1675],{},"mêmes repères sur tableau, unifilaire et plan de situation ;",[34,1677,1678],{},"conservation des notices et des modifications dans le dossier de l’installation.",[11,1680,1681],{},"Cette revue ne remplace pas le calcul électrique, la réalisation par une personne compétente ni le contrôle réglementaire par un organisme agréé.",[23,1683,1685],{"id":1684},"quand-réviser-à-nouveau-le-schéma","Quand réviser à nouveau le schéma",[11,1687,1688],{},"Une mise à jour n’est pas réservée au remplacement complet de la pompe à chaleur. Elle est aussi nécessaire lorsqu’un appoint est activé, qu’une option électrique est ajoutée, qu’un modèle monophasé devient triphasé ou qu’une régulation externe est raccordée à demeure. Toute modification du différentiel, du disjoncteur, du câble ou des phases doit rejoindre l’as-built.",[11,1690,1691],{},"Comparez les données avant\u002Faprès, les conducteurs disponibles, les protections, les prescriptions du nouveau modèle, les positions et les notices. Un circuit déconnecté mais encore présent doit être identifié sans ambiguïté. Laisser apparaître un appareil hors service comme actif est aussi trompeur qu’omettre une résistance nouvellement raccordée.",[23,1693,1695],{"id":1694},"exemple-groupe-extérieur-module-intérieur-et-appoint","Exemple : groupe extérieur, module intérieur et appoint",[11,1697,1698],{},"Imaginons une installation composée d'un groupe extérieur triphasé, d'un module intérieur alimenté séparément et d'un appoint électrique. Ne la réduisez pas immédiatement à un seul bloc. Vérifiez sur le modèle livré et le câblage réel si trois circuits terminaux existent ou si certains éléments sont alimentés depuis le groupe extérieur. Seuls les circuits réellement séparés reçoivent chaîne de protection, canalisation et repère propres.",[11,1700,1701],{},"Pour chaque départ existant, relevez l'absorption électrique maximale dans la documentation contraignante du fabricant, pas la puissance thermique d'une brochure commerciale. Indiquez phases, neutre et conducteur de protection selon le câble posé. Un groupe extérieur triphasé peut côtoyer une commande ou un module intérieur monophasé ; la fonction commune « pompe à chaleur » n'efface pas ces différences. Examinez surtout l'appoint, dont la puissance raccordée et les étages peuvent dépasser largement l'entrée du compresseur.",[11,1703,1704],{},"Placez groupe extérieur, module intérieur, dispositif fixe de sectionnement et appoint séparé à leur emplacement réel sur le plan de position. Ne présentez pas bus, sondes et commandes comme des circuits de puissance. S'ils sont utiles à la maintenance, expliquez-les dans la légende ou la documentation technique sans les confondre avec l'alimentation secteur.",[23,1706,1708],{"id":1707},"tenir-compte-de-la-mise-en-service-et-des-modes-de-fonctionnement","Tenir compte de la mise en service et des modes de fonctionnement",[11,1710,1711],{},"Après mise en service, confrontez le départ dessiné aux plaques, bornes, paramètres installateur et relevés d'essai. Limitation de charge, contact de blocage ou gestion énergétique peuvent modifier le fonctionnement, mais ne remplacent pas automatiquement le dimensionnement et l'analyse des protections. Ne documentez comme hypothèse que les réglages réellement appliqués, protégés contre une modification involontaire et pertinents pour l'étude.",[11,1713,1714],{},"Examinez des situations qu'un cycle normal masque facilement :",[31,1716,1717,1720,1723,1726,1729,1732],{},[34,1718,1719],{},"dégivrage avec appoint simultané ;",[34,1721,1722],{},"mode secours ou cycle sanitaire utilisant la résistance ;",[34,1724,1725],{},"démarrage et comportement du variateur selon le fabricant ;",[34,1727,1728],{},"alimentation distincte d'un chauffage de bac ou de traçage ;",[34,1730,1731],{},"sectionnement sûr pour la maintenance ;",[34,1733,1734],{},"redémarrage après coupure ou délestage.",[11,1736,1737],{},"Cette liste n'impose ni disjoncteur, ni DDR, ni section universels. Elle identifie les données que le concepteur doit résoudre avec la notice exacte et les conditions de pose. Mesures et temps de coupure restent à vérifier sur place.",[23,1739,1741],{"id":1740},"interfaces-avec-pv-batterie-et-gestion-de-charge","Interfaces avec PV, batterie et gestion de charge",[11,1743,1744],{},"Une pompe à chaleur peut recevoir un signal d'autoconsommation sans être électriquement « derrière l'onduleur PV » si la topologie AC dit autre chose. Dessinez les chemins d'énergie selon les raccordements réels et décrivez séparément communications ou contacts smart-grid. En alimentation de secours, vérifiez que la pompe dépend effectivement du tableau secouru et que limites de démarrage et de puissance autorisent ce mode. Un réglage dans une application ne prouve pas le raccordement.",[11,1746,1747,1748,1752],{},"La ",[143,1749,1751],{"href":444,"rel":1750},[420],"publication officielle du RGIE Livre 1"," fixe le cadre général des schémas et protections. Valeurs d'entrée, protections externes et variantes de raccordement propres au modèle proviennent de la notice actuelle de l'équipement installé.",[23,1754,1756],{"id":1755},"documenter-dans-planelec","Documenter dans PlanElec",[11,1758,1759,1760,1763],{},"Dans ",[143,1761,433],{"href":1762},"\u002Ffr\u002F",", vous pouvez rattacher les éléments de la pompe à chaleur aux circuits réellement posés, saisir protections et canalisations, puis exporter schéma unifilaire et plan de situation en PDF. Une légende reste nécessaire pour tout symbole propre au projet. L’auto-contrôle indicatif peut signaler certaines saisies prises en charge ; il ne certifie ni conformité RGIE, ni accord constructeur, et ne produit pas un rapport officiel.",[23,1765,1767],{"id":1766},"sources-et-version-examinée","Sources et version examinée",[11,1769,1770,1771,1775],{},"La base réglementaire est la publication officielle du ",[143,1772,1774],{"href":444,"rel":1773},[420],"RGIE Livre 1",", notamment le tableau 2.23 et la partie 3 relative aux plans, complétée par la notice électrique du modèle installé. Version examinée : Livre 1 V06, 29 août 2026.",{"title":78,"searchDepth":449,"depth":449,"links":1777},[1778,1779,1780,1781,1782,1783,1784,1790,1791,1792,1793,1794,1795,1796],{"id":1399,"depth":449,"text":1400},{"id":1435,"depth":449,"text":1436},{"id":1474,"depth":449,"text":1475},{"id":1515,"depth":449,"text":1516},{"id":1547,"depth":449,"text":1548},{"id":1582,"depth":449,"text":1583},{"id":1622,"depth":449,"text":1623,"children":1785},[1786,1787,1788,1789],{"id":1626,"depth":460,"text":1627},{"id":1633,"depth":460,"text":1634},{"id":1640,"depth":460,"text":1641},{"id":1647,"depth":460,"text":1648},{"id":1654,"depth":449,"text":1655},{"id":1684,"depth":449,"text":1685},{"id":1694,"depth":449,"text":1695},{"id":1707,"depth":449,"text":1708},{"id":1740,"depth":449,"text":1741},{"id":1755,"depth":449,"text":1756},{"id":1766,"depth":449,"text":1767},"Représentez unités extérieure et intérieure, appoint, protections, câble et données constructeur d’une pompe à chaleur selon le RGIE Livre 1 V06.","fr",{},"\u002Fblog\u002Fheat-pump-single-line-diagram.fr",{"title":1384,"description":1797},"pompe-chaleur-schema-unifilaire","blog\u002Fheat-pump-single-line-diagram.fr",[1805,1806,1807,1377,1808,1809,1810],"Pompe à chaleur","Schéma unifilaire","RGIE","Unité extérieure","Appoint électrique","Belgique","ZIHSQDwmcxks1-wtt7WBpTQhpiSvAy13uPAisAu1ozE",{"id":4,"title":5,"articleId":6,"body":1813,"category":471,"date":472,"description":473,"extension":474,"lastUpdated":472,"locale":475,"meta":2102,"navigation":477,"path":478,"publishDate":472,"readTime":479,"refreshInterval":480,"seo":2103,"slug":482,"stem":483,"tags":2104,"__hash__":492},{"type":8,"value":1814,"toc":2081},[1815,1819,1821,1823,1825,1843,1845,1847,1849,1851,1856,1858,1863,1871,1873,1875,1893,1897,1899,1901,1913,1917,1919,1921,1935,1941,1943,1949,1961,1965,1967,1969,1971,1973,1975,1977,1979,1981,1983,1985,1987,2001,2003,2005,2007,2009,2023,2025,2027,2029,2031,2033,2035,2037,2039,2053,2055,2057,2059,2061,2063,2068,2070,2074,2076],[11,1816,13,1817,18],{},[15,1818,17],{},[11,1820,21],{},[23,1822,26],{"id":25},[11,1824,29],{},[31,1826,1827,1829,1831,1833,1835,1837,1839,1841],{},[34,1828,36],{},[34,1830,39],{},[34,1832,42],{},[34,1834,45],{},[34,1836,48],{},[34,1838,51],{},[34,1840,54],{},[34,1842,57],{},[11,1844,60],{},[23,1846,64],{"id":63},[11,1848,67],{},[11,1850,70],{},[72,1852,1854],{"className":1853,"code":76,"language":77,"meta":78},[75],[80,1855,76],{"__ignoreMap":78},[11,1857,84],{},[72,1859,1861],{"className":1860,"code":88,"language":77,"meta":78},[75],[80,1862,88],{"__ignoreMap":78},[11,1864,1865,96,1867,100,1869,104],{},[80,1866,95],{},[80,1868,99],{},[80,1870,103],{},[23,1872,108],{"id":107},[11,1874,111],{},[113,1876,1877,1879,1881,1883,1885,1887,1889,1891],{},[34,1878,117],{},[34,1880,120],{},[34,1882,123],{},[34,1884,126],{},[34,1886,129],{},[34,1888,132],{},[34,1890,135],{},[34,1892,138],{},[11,1894,141,1895,147],{},[143,1896,146],{"href":145},[23,1898,151],{"id":150},[11,1900,154],{},[31,1902,1903,1905,1907,1909,1911],{},[34,1904,159],{},[34,1906,162],{},[34,1908,165],{},[34,1910,168],{},[34,1912,171],{},[11,1914,174,1915,179],{},[143,1916,178],{"href":177},[23,1918,183],{"id":182},[11,1920,186],{},[31,1922,1923,1927,1931],{},[34,1924,1925,194],{},[80,1926,193],{},[34,1928,1929,200],{},[80,1930,199],{},[34,1932,1933,206],{},[80,1934,205],{},[11,1936,209,1937,213,1939,218],{},[80,1938,212],{},[143,1940,217],{"href":216},[23,1942,222],{"id":221},[11,1944,225,1945,229,1947,233],{},[15,1946,228],{},[15,1948,232],{},[31,1950,1951,1953,1955,1957,1959],{},[34,1952,238],{},[34,1954,241],{},[34,1956,244],{},[34,1958,247],{},[34,1960,250],{},[11,1962,253,1963,258],{},[143,1964,257],{"href":256},[23,1966,262],{"id":261},[264,1968,267],{"id":266},[11,1970,270],{},[264,1972,274],{"id":273},[11,1974,277],{},[264,1976,281],{"id":280},[11,1978,284],{},[264,1980,288],{"id":287},[11,1982,291],{},[23,1984,295],{"id":294},[11,1986,298],{},[31,1988,1989,1991,1993,1995,1997,1999],{},[34,1990,303],{},[34,1992,306],{},[34,1994,309],{},[34,1996,312],{},[34,1998,315],{},[34,2000,318],{},[11,2002,321],{},[23,2004,325],{"id":324},[11,2006,328],{},[11,2008,331],{},[31,2010,2011,2013,2015,2017,2019,2021],{},[34,2012,336],{},[34,2014,339],{},[34,2016,342],{},[34,2018,345],{},[34,2020,348],{},[34,2022,351],{},[11,2024,354],{},[23,2026,358],{"id":357},[11,2028,361],{},[11,2030,364],{},[11,2032,367],{},[23,2034,371],{"id":370},[11,2036,374],{},[11,2038,377],{},[31,2040,2041,2043,2045,2047,2049,2051],{},[34,2042,382],{},[34,2044,385],{},[34,2046,388],{},[34,2048,391],{},[34,2050,394],{},[34,2052,397],{},[11,2054,400],{},[11,2056,403],{},[11,2058,406],{},[23,2060,410],{"id":409},[11,2062,413],{},[11,2064,141,2065,422],{},[143,2066,421],{"href":418,"rel":2067},[420],[23,2069,426],{"id":425},[11,2071,429,2072,434],{},[143,2073,433],{"href":432},[23,2075,438],{"id":437},[11,2077,441,2078,447],{},[143,2079,446],{"href":444,"rel":2080},[420],{"title":78,"searchDepth":449,"depth":449,"links":2082},[2083,2084,2085,2086,2087,2088,2089,2095,2096,2097,2098,2099,2100,2101],{"id":25,"depth":449,"text":26},{"id":63,"depth":449,"text":64},{"id":107,"depth":449,"text":108},{"id":150,"depth":449,"text":151},{"id":182,"depth":449,"text":183},{"id":221,"depth":449,"text":222},{"id":261,"depth":449,"text":262,"children":2090},[2091,2092,2093,2094],{"id":266,"depth":460,"text":267},{"id":273,"depth":460,"text":274},{"id":280,"depth":460,"text":281},{"id":287,"depth":460,"text":288},{"id":294,"depth":449,"text":295},{"id":324,"depth":449,"text":325},{"id":357,"depth":449,"text":358},{"id":370,"depth":449,"text":371},{"id":409,"depth":449,"text":410},{"id":425,"depth":449,"text":426},{"id":437,"depth":449,"text":438},{},{"title":5,"description":473},[485,486,487,488,489,490,491],1788343842899]