[{"data":1,"prerenderedAt":1959},["ShallowReactive",2],{"blog-post-de-badezimmer-kabel-arei-zonen":3,"blog-alternates-bathroom-cables-arei-zones":454},{"id":4,"title":5,"articleId":6,"body":7,"category":423,"date":424,"description":425,"extension":426,"lastUpdated":424,"locale":427,"meta":428,"navigation":429,"path":430,"publishDate":424,"readTime":431,"refreshInterval":432,"seo":433,"slug":434,"stem":435,"tags":436,"__hash__":453},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.de.md","Welche Kabel darf ich im Badezimmer verwenden? (AREI Zonen)","bathroom-cables-arei-zones",{"type":8,"value":9,"toc":409},"minimark",[10,15,28,32,39,104,117,120,124,242,247,279,283,353,357,364,377,381,384,388,403],[11,12,14],"h2",{"id":13},"xvb-ist-immer-erlaubt-vob-nur-eingeschränkt","XVB ist immer erlaubt — VOB nur eingeschränkt",[16,17,18,19,23,24,27],"p",{},"Bei der Elektroinstallation im Badezimmer gelten in Belgien besondere Vorschriften. Die wichtigste Faustregel: ",[20,21,22],"strong",{},"XVB-Kabel"," (Mantelleitung) ist in allen Badezimmerzonen erlaubt. ",[20,25,26],{},"VOB-Draht in Leerrohr"," (Preflex) unterliegt Einschränkungen — insbesondere in Hohlwänden.",[11,29,31],{"id":30},"die-arei-badezimmerzonen","Die AREI-Badezimmerzonen",[16,33,34,35,38],{},"Das AREI definiert ",[20,36,37],{},"drei Bereiche"," rund um Badewanne und Dusche: Bereich 0, Bereich 1, Bereich 2 (nur bei Badewannen) und den Bereich außerhalb der Zonen (Art. 7.1.3.2).",[40,41,42,58],"table",{},[43,44,45],"thead",{},[46,47,48,52,55],"tr",{},[49,50,51],"th",{},"Zone",[49,53,54],{},"Bereich",[49,56,57],{},"Erlaubte Installation",[59,60,61,75,88],"tbody",{},[46,62,63,69,72],{},[64,65,66],"td",{},[20,67,68],{},"Bereich 0",[64,70,71],{},"Inneres der Badewanne\u002FDusche",[64,73,74],{},"Nur SELV ≤ 12V, IPX7",[46,76,77,82,85],{},[64,78,79],{},[20,80,81],{},"Bereich 1",[64,83,84],{},"Senkrecht über Bereich 0, bis 2,25 m Höhe",[64,86,87],{},"Fest angeschlossene Geräte ≥ IPX4; SELV-Steckdosen und SELV-Schalter erlaubt (Art. 7.1.5.2c Nr. 2 und 4)",[46,89,90,95,101],{},[64,91,92],{},[20,93,94],{},"Bereich 2",[64,96,97,98],{},"60 cm um Bereich 1 herum — ",[20,99,100],{},"nur bei Badewannen",[64,102,103],{},"Steckdosen mit 30mA-FI erlaubt, Geräte ≥ IPX4",[105,106,107],"blockquote",{},[16,108,109,112,113,116],{},[20,110,111],{},"Wichtig:"," Bereich 2 ist für Duschen ",[20,114,115],{},"nicht festgelegt"," (Art. 7.1.3.2 Nr. 3b). Bei Duschen folgt auf Bereich 1 direkt der Bereich außerhalb der Zonen.",[16,118,119],{},"Außerhalb dieser Zonen gelten die normalen Installationsregeln.",[11,121,123],{"id":122},"kabeltypen-und-ihre-zulässigkeit","Kabeltypen und ihre Zulässigkeit",[40,125,126,148],{},[43,127,128],{},[46,129,130,133,136,139,142,145],{},[49,131,132],{},"Kabeltyp",[49,134,135],{},"CPR-Klasse",[49,137,138],{},"Zone 0",[49,140,141],{},"Zone 1",[49,143,144],{},"Zone 2",[49,146,147],{},"Außerhalb",[59,149,150,170,188,206,225],{},[46,151,152,157,160,163,166,168],{},[64,153,154],{},[20,155,156],{},"XVB 3G2,5",[64,158,159],{},"Cca",[64,161,162],{},"Nein",[64,164,165],{},"Ja",[64,167,165],{},[64,169,165],{},[46,171,172,177,179,181,184,186],{},[64,173,174],{},[20,175,176],{},"XVB 3G1,5",[64,178,159],{},[64,180,162],{},[64,182,183],{},"Ja (Beleuchtung)",[64,185,165],{},[64,187,165],{},[46,189,190,195,198,200,202,204],{},[64,191,192],{},[20,193,194],{},"VOB in Preflex grau",[64,196,197],{},"—",[64,199,162],{},[64,201,165],{},[64,203,165],{},[64,205,165],{},[46,207,208,213,215,217,220,223],{},[64,209,210],{},[20,211,212],{},"VOB in Preflex grün",[64,214,197],{},[64,216,162],{},[64,218,219],{},"Nein (Hohlwand)",[64,221,222],{},"Eingeschränkt",[64,224,165],{},[46,226,227,232,234,236,238,240],{},[64,228,229],{},[20,230,231],{},"H07Z1-U (halogenfrei)",[64,233,159],{},[64,235,162],{},[64,237,165],{},[64,239,165],{},[64,241,165],{},[243,244,246],"h3",{"id":245},"wichtige-hinweise-zu-den-kabeltypen","Wichtige Hinweise zu den Kabeltypen",[248,249,250,257,267,273],"ul",{},[251,252,253,256],"li",{},[20,254,255],{},"XVB"," (Mantelleitung): Immer die sichere Wahl. Geeignet für Unterputz, Aufputz und in Kabelkanälen.",[251,258,259,262,263,266],{},[20,260,261],{},"Preflex grau"," (normales Leerrohr mit vorgezogenem VOB): Zulässig in Massivwänden. ",[20,264,265],{},"Nicht"," in Hohlwänden\u002FZwischendecken verwenden.",[251,268,269,272],{},[20,270,271],{},"Preflex Safe (grün)",": In Massivwänden ist Preflex Safe (Cca) auch in Zone 1 zulässig. Die Einschränkung betrifft Hohlwände (droogbouw), nicht die Zone selbst.",[251,274,275,278],{},[20,276,277],{},"H07Z1-U",": Halogenfreier Draht, besonders für sensible Bereiche empfohlen. Hinweis: H07Z1-U als Einzeldraht hat keine inhärente CPR-Klasse Cca — die Klasse bezieht sich auf das Kabelsystem (Draht + Rohr). H07Z1-U in Preflex Safe erreicht Cca.",[11,280,282],{"id":281},"querschnitt-tabelle","Querschnitt-Tabelle",[40,284,285,298],{},[43,286,287],{},[46,288,289,292,295],{},[49,290,291],{},"Verwendung",[49,293,294],{},"Min. Querschnitt",[49,296,297],{},"Sicherung",[59,299,300,311,322,332,342],{},[46,301,302,305,308],{},[64,303,304],{},"Beleuchtung",[64,306,307],{},"1,5 mm²",[64,309,310],{},"10A oder 16A",[46,312,313,316,319],{},[64,314,315],{},"Steckdosen",[64,317,318],{},"2,5 mm²",[64,320,321],{},"16A oder 20A",[46,323,324,327,329],{},[64,325,326],{},"Waschmaschine\u002FTrockner",[64,328,318],{},[64,330,331],{},"16A (eigener Stromkreis)",[46,333,334,337,339],{},[64,335,336],{},"Elektrischer Boiler (Untertisch, ≤ 2 kW)",[64,338,318],{},[64,340,341],{},"16A",[46,343,344,347,350],{},[64,345,346],{},"Elektrischer Durchlauferhitzer (18–27 kW)",[64,348,349],{},"6 mm² (32A) oder 10 mm² (40A, Dreiphasen)",[64,351,352],{},"32A oder 40A",[11,354,356],{"id":355},"_30ma-differentialschutz-ist-pflicht","30mA-Differentialschutz ist Pflicht",[16,358,359,360,363],{},"Gemäß AREI Art. 7.1.4.3 müssen ",[20,361,362],{},"alle Stromkreise im Badezimmer"," durch einen 30mA-FI-Schutzschalter gesichert sein — ohne Ausnahme. Dies gilt für Beleuchtung, Steckdosen und fest angeschlossene Geräte gleichermaßen.",[105,365,366],{},[16,367,368,371,372,376],{},[20,369,370],{},"Achtung",": Auch Stromkreise, die nur ",[373,374,375],"em",{},"durch"," das Badezimmer verlaufen (z.B. Kabel zum Dachboden), müssen den Zonenvorgaben entsprechen, wenn sie innerhalb der Schutzzonen verlegt werden.",[11,378,380],{"id":379},"potentialausgleich-im-badezimmer","Potentialausgleich im Badezimmer",[16,382,383],{},"Wichtig: Das AREI (Art. 7.1.4.4) verlangt einen zusätzlichen Potentialausgleich im Badezimmer — alle metallischen Teile (Wasserrohre, Heizkörper, Badewanne, Abflussrohre) müssen über einen Schutzleiter miteinander und mit der Haupterdungsschiene verbunden werden. Fehlender Potentialausgleich ist ein häufiger Mängelgrund bei der Keuring.",[11,385,387],{"id":386},"verwandte-artikel","Verwandte Artikel",[248,389,390,397],{},[251,391,392],{},[393,394,396],"a",{"href":395},"\u002Fde\u002Fblog\u002F30ma-fi-pro-steckdose","Brauche ich einen 30mA FI-Schalter für jede Steckdose?",[251,398,399],{},[393,400,402],{"href":401},"\u002Fde\u002Fblog\u002Felektrische-abnahme","Elektrische Abnahme in Belgien — was Sie wissen müssen",[16,404,405],{},[393,406,408],{"href":407},"\u002F","Planen Sie Ihre Badezimmer-Elektrik mit PlanElec — kostenlos →",{"title":410,"searchDepth":411,"depth":411,"links":412},"",2,[413,414,415,419,420,421,422],{"id":13,"depth":411,"text":14},{"id":30,"depth":411,"text":31},{"id":122,"depth":411,"text":123,"children":416},[417],{"id":245,"depth":418,"text":246},3,{"id":281,"depth":411,"text":282},{"id":355,"depth":411,"text":356},{"id":379,"depth":411,"text":380},{"id":386,"depth":411,"text":387},"faq","2026-03-09","XVB ist immer erlaubt, VOB in Leerrohr nur eingeschränkt. Erfahren Sie, welche Kabeltypen in welcher AREI-Zone zulässig sind und worauf Sie achten müssen.","md","de",{},true,"\u002Fblog\u002Fbathroom-cables-arei-zones.de","4 min",12,{"title":5,"description":425},"badezimmer-kabel-arei-zonen","blog\u002Fbathroom-cables-arei-zones.de",[437,438,439,440,255,441,442,443,444,445,446,447,448,449,450,451,452],"AREI","RGIE","Badezimmer","Zonen","VOB","Preflex","Kabel","FI-Schutzschalter","30mA","Stromabnahme","Keuring","elektrische Installation","Belgien","Eindrahtschema","Situationsplan","CPR","u2AFNJg-k2r8mglgueyvhWHNcS5d15hMluMaeHzJQkE",[455,756,1163,1562],{"id":4,"title":5,"articleId":6,"body":456,"category":423,"date":424,"description":425,"extension":426,"lastUpdated":424,"locale":427,"meta":753,"navigation":429,"path":430,"publishDate":424,"readTime":431,"refreshInterval":432,"seo":754,"slug":434,"stem":435,"tags":755,"__hash__":453},{"type":8,"value":457,"toc":742},[458,460,466,468,472,518,526,528,530,630,632,652,654,708,710,714,722,724,726,728,738],[11,459,14],{"id":13},[16,461,18,462,23,464,27],{},[20,463,22],{},[20,465,26],{},[11,467,31],{"id":30},[16,469,34,470,38],{},[20,471,37],{},[40,473,474,484],{},[43,475,476],{},[46,477,478,480,482],{},[49,479,51],{},[49,481,54],{},[49,483,57],{},[59,485,486,496,506],{},[46,487,488,492,494],{},[64,489,490],{},[20,491,68],{},[64,493,71],{},[64,495,74],{},[46,497,498,502,504],{},[64,499,500],{},[20,501,81],{},[64,503,84],{},[64,505,87],{},[46,507,508,512,516],{},[64,509,510],{},[20,511,94],{},[64,513,97,514],{},[20,515,100],{},[64,517,103],{},[105,519,520],{},[16,521,522,112,524,116],{},[20,523,111],{},[20,525,115],{},[16,527,119],{},[11,529,123],{"id":122},[40,531,532,548],{},[43,533,534],{},[46,535,536,538,540,542,544,546],{},[49,537,132],{},[49,539,135],{},[49,541,138],{},[49,543,141],{},[49,545,144],{},[49,547,147],{},[59,549,550,566,582,598,614],{},[46,551,552,556,558,560,562,564],{},[64,553,554],{},[20,555,156],{},[64,557,159],{},[64,559,162],{},[64,561,165],{},[64,563,165],{},[64,565,165],{},[46,567,568,572,574,576,578,580],{},[64,569,570],{},[20,571,176],{},[64,573,159],{},[64,575,162],{},[64,577,183],{},[64,579,165],{},[64,581,165],{},[46,583,584,588,590,592,594,596],{},[64,585,586],{},[20,587,194],{},[64,589,197],{},[64,591,162],{},[64,593,165],{},[64,595,165],{},[64,597,165],{},[46,599,600,604,606,608,610,612],{},[64,601,602],{},[20,603,212],{},[64,605,197],{},[64,607,162],{},[64,609,219],{},[64,611,222],{},[64,613,165],{},[46,615,616,620,622,624,626,628],{},[64,617,618],{},[20,619,231],{},[64,621,159],{},[64,623,162],{},[64,625,165],{},[64,627,165],{},[64,629,165],{},[243,631,246],{"id":245},[248,633,634,638,644,648],{},[251,635,636,256],{},[20,637,255],{},[251,639,640,262,642,266],{},[20,641,261],{},[20,643,265],{},[251,645,646,272],{},[20,647,271],{},[251,649,650,278],{},[20,651,277],{},[11,653,282],{"id":281},[40,655,656,666],{},[43,657,658],{},[46,659,660,662,664],{},[49,661,291],{},[49,663,294],{},[49,665,297],{},[59,667,668,676,684,692,700],{},[46,669,670,672,674],{},[64,671,304],{},[64,673,307],{},[64,675,310],{},[46,677,678,680,682],{},[64,679,315],{},[64,681,318],{},[64,683,321],{},[46,685,686,688,690],{},[64,687,326],{},[64,689,318],{},[64,691,331],{},[46,693,694,696,698],{},[64,695,336],{},[64,697,318],{},[64,699,341],{},[46,701,702,704,706],{},[64,703,346],{},[64,705,349],{},[64,707,352],{},[11,709,356],{"id":355},[16,711,359,712,363],{},[20,713,362],{},[105,715,716],{},[16,717,718,371,720,376],{},[20,719,370],{},[373,721,375],{},[11,723,380],{"id":379},[16,725,383],{},[11,727,387],{"id":386},[248,729,730,734],{},[251,731,732],{},[393,733,396],{"href":395},[251,735,736],{},[393,737,402],{"href":401},[16,739,740],{},[393,741,408],{"href":407},{"title":410,"searchDepth":411,"depth":411,"links":743},[744,745,746,749,750,751,752],{"id":13,"depth":411,"text":14},{"id":30,"depth":411,"text":31},{"id":122,"depth":411,"text":123,"children":747},[748],{"id":245,"depth":418,"text":246},{"id":281,"depth":411,"text":282},{"id":355,"depth":411,"text":356},{"id":379,"depth":411,"text":380},{"id":386,"depth":411,"text":387},{},{"title":5,"description":425},[437,438,439,440,255,441,442,443,444,445,446,447,448,449,450,451,452],{"id":757,"title":758,"articleId":6,"body":759,"category":423,"date":424,"description":1143,"extension":426,"lastUpdated":424,"locale":1144,"meta":1145,"navigation":429,"path":1146,"publishDate":424,"readTime":431,"refreshInterval":432,"seo":1147,"slug":6,"stem":1148,"tags":1149,"__hash__":1162},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.en.md","Which Cables Can I Use in the Bathroom? (AREI Zones)",{"type":8,"value":760,"toc":1132},[761,765,776,780,787,842,854,857,861,974,978,1006,1010,1079,1083,1090,1102,1106,1109,1113,1127],[11,762,764],{"id":763},"xvb-is-always-allowed-vob-only-with-restrictions","XVB is always allowed — VOB only with restrictions",[16,766,767,768,771,772,775],{},"Bathroom electrical installations in Belgium are subject to special regulations. The key rule of thumb: ",[20,769,770],{},"XVB cable"," (sheathed cable) is permitted in all bathroom zones. ",[20,773,774],{},"VOB wire in conduit"," (Preflex) has restrictions — especially in hollow walls.",[11,777,779],{"id":778},"the-arei-bathroom-zones","The AREI bathroom zones",[16,781,782,783,786],{},"The AREI defines ",[20,784,785],{},"three zones"," around bathtubs and showers: Zone 0, Zone 1, Zone 2 (bathtubs only), and the area outside the zones (Art. 7.1.3.2).",[40,788,789,801],{},[43,790,791],{},[46,792,793,795,798],{},[49,794,51],{},[49,796,797],{},"Area",[49,799,800],{},"Permitted installation",[59,802,803,815,827],{},[46,804,805,809,812],{},[64,806,807],{},[20,808,138],{},[64,810,811],{},"Inside the bathtub\u002Fshower",[64,813,814],{},"SELV ≤ 12V only, IPX7",[46,816,817,821,824],{},[64,818,819],{},[20,820,141],{},[64,822,823],{},"Vertically above Zone 0, up to 2.25 m height",[64,825,826],{},"Fixed appliances ≥ IPX4; SELV sockets and SELV switches permitted (Art. 7.1.5.2c Nr. 2 and 4)",[46,828,829,833,839],{},[64,830,831],{},[20,832,144],{},[64,834,835,836],{},"60 cm around Zone 1 — ",[20,837,838],{},"bathtubs only",[64,840,841],{},"Sockets with 30mA RCD allowed, appliances ≥ IPX4",[105,843,844],{},[16,845,846,849,850,853],{},[20,847,848],{},"Important:"," Zone 2 is ",[20,851,852],{},"not defined"," for showers (Art. 7.1.3.2 Nr. 3b). For showers, Zone 1 is followed directly by the area outside the zones.",[16,855,856],{},"Outside these zones, normal installation rules apply.",[11,858,860],{"id":859},"cable-types-and-their-permissibility","Cable types and their permissibility",[40,862,863,882],{},[43,864,865],{},[46,866,867,870,873,875,877,879],{},[49,868,869],{},"Cable type",[49,871,872],{},"CPR class",[49,874,138],{},[49,876,141],{},[49,878,144],{},[49,880,881],{},"Outside zones",[59,883,884,903,921,938,957],{},[46,885,886,891,893,896,899,901],{},[64,887,888],{},[20,889,890],{},"XVB 3G2.5",[64,892,159],{},[64,894,895],{},"No",[64,897,898],{},"Yes",[64,900,898],{},[64,902,898],{},[46,904,905,910,912,914,917,919],{},[64,906,907],{},[20,908,909],{},"XVB 3G1.5",[64,911,159],{},[64,913,895],{},[64,915,916],{},"Yes (lighting)",[64,918,898],{},[64,920,898],{},[46,922,923,928,930,932,934,936],{},[64,924,925],{},[20,926,927],{},"VOB in grey Preflex",[64,929,197],{},[64,931,895],{},[64,933,898],{},[64,935,898],{},[64,937,898],{},[46,939,940,945,947,949,952,955],{},[64,941,942],{},[20,943,944],{},"VOB in green Preflex",[64,946,197],{},[64,948,895],{},[64,950,951],{},"No (hollow wall)",[64,953,954],{},"Restricted",[64,956,898],{},[46,958,959,964,966,968,970,972],{},[64,960,961],{},[20,962,963],{},"H07Z1-U (halogen-free)",[64,965,159],{},[64,967,895],{},[64,969,898],{},[64,971,898],{},[64,973,898],{},[243,975,977],{"id":976},"important-notes-on-cable-types","Important notes on cable types",[248,979,980,985,995,1001],{},[251,981,982,984],{},[20,983,255],{}," (sheathed cable): Always the safe choice. Suitable for flush mounting, surface mounting, and cable trays.",[251,986,987,990,991,994],{},[20,988,989],{},"Grey Preflex"," (standard conduit with pre-pulled VOB): Permitted in solid walls. ",[20,992,993],{},"Not"," allowed in hollow walls or suspended ceilings.",[251,996,997,1000],{},[20,998,999],{},"Preflex Safe (green)",": In solid walls, Preflex Safe (Cca) is also permitted in Zone 1. The restriction applies to hollow walls (droogbouw), not the zone itself.",[251,1002,1003,1005],{},[20,1004,277],{},": Halogen-free wire, particularly recommended for sensitive areas. Note: H07Z1-U as a single wire does not inherently have a CPR class of Cca — the class refers to the cable system (wire + conduit). H07Z1-U in Preflex Safe achieves Cca.",[11,1007,1009],{"id":1008},"cross-section-table","Cross-section table",[40,1011,1012,1025],{},[43,1013,1014],{},[46,1015,1016,1019,1022],{},[49,1017,1018],{},"Usage",[49,1020,1021],{},"Min. cross-section",[49,1023,1024],{},"Circuit breaker",[59,1026,1027,1038,1049,1059,1068],{},[46,1028,1029,1032,1035],{},[64,1030,1031],{},"Lighting",[64,1033,1034],{},"1.5 mm²",[64,1036,1037],{},"10A or 16A",[46,1039,1040,1043,1046],{},[64,1041,1042],{},"Sockets",[64,1044,1045],{},"2.5 mm²",[64,1047,1048],{},"16A or 20A",[46,1050,1051,1054,1056],{},[64,1052,1053],{},"Washing machine \u002F dryer",[64,1055,1045],{},[64,1057,1058],{},"16A (dedicated circuit)",[46,1060,1061,1064,1066],{},[64,1062,1063],{},"Electric water heater (under-sink, ≤ 2 kW)",[64,1065,1045],{},[64,1067,341],{},[46,1069,1070,1073,1076],{},[64,1071,1072],{},"Electric instantaneous water heater (18–27 kW)",[64,1074,1075],{},"6 mm² (32A) or 10 mm² (40A, three-phase)",[64,1077,1078],{},"32A or 40A",[11,1080,1082],{"id":1081},"_30ma-differential-protection-is-mandatory","30mA differential protection is mandatory",[16,1084,1085,1086,1089],{},"According to AREI Art. 7.1.4.3, ",[20,1087,1088],{},"all circuits in the bathroom"," must be protected by a 30mA RCD — no exceptions. This applies equally to lighting, sockets, and fixed appliances.",[105,1091,1092],{},[16,1093,1094,1097,1098,1101],{},[20,1095,1096],{},"Warning",": Even circuits that merely ",[373,1099,1100],{},"pass through"," the bathroom (e.g., cables to the attic) must comply with zone requirements if they run within the protection zones.",[11,1103,1105],{"id":1104},"equipotential-bonding-in-the-bathroom","Equipotential bonding in the bathroom",[16,1107,1108],{},"Important: The AREI (Art. 7.1.4.4) requires supplementary equipotential bonding in the bathroom — all metallic parts (water pipes, radiators, bathtub, drain pipes) must be connected to each other and to the main earthing terminal via a protective conductor. Missing equipotential bonding is a common reason for inspection failure.",[11,1110,1112],{"id":1111},"related-articles","Related articles",[248,1114,1115,1121],{},[251,1116,1117],{},[393,1118,1120],{"href":1119},"\u002Fen\u002Fblog\u002F30ma-rcd-per-socket","Do I need a 30mA RCD for every socket?",[251,1122,1123],{},[393,1124,1126],{"href":1125},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical inspection in Belgium — what you need to know",[16,1128,1129],{},[393,1130,1131],{"href":407},"Plan your bathroom electrics with PlanElec — free →",{"title":410,"searchDepth":411,"depth":411,"links":1133},[1134,1135,1136,1139,1140,1141,1142],{"id":763,"depth":411,"text":764},{"id":778,"depth":411,"text":779},{"id":859,"depth":411,"text":860,"children":1137},[1138],{"id":976,"depth":418,"text":977},{"id":1008,"depth":411,"text":1009},{"id":1081,"depth":411,"text":1082},{"id":1104,"depth":411,"text":1105},{"id":1111,"depth":411,"text":1112},"XVB is always permitted, VOB in conduit only with restrictions. Learn which cable types are allowed in each AREI zone and what to watch out for.","en",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.en",{"title":758,"description":1143},"blog\u002Fbathroom-cables-arei-zones.en",[437,438,1150,1151,255,441,442,1152,1153,445,1154,1155,1156,1157,1158,1159,450,1160,1161,452],"bathroom","zones","cables","RCD","inspection","keuring","electrical installation","Belgium","single-line diagram","eendraadschema","schéma unifilaire","situation plan","ZgbQLsxNNJRX4smfwHGocQCncIUqNvJMapcLmRmLIdU",{"id":1164,"title":1165,"articleId":6,"body":1166,"category":423,"date":424,"description":1546,"extension":426,"lastUpdated":424,"locale":1547,"meta":1548,"navigation":429,"path":1549,"publishDate":424,"readTime":431,"refreshInterval":432,"seo":1550,"slug":1551,"stem":1552,"tags":1553,"__hash__":1561},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.fr.md","Quels câbles utiliser dans la salle de bain ? (Zones RGIE)",{"type":8,"value":1167,"toc":1535},[1168,1172,1183,1187,1194,1249,1261,1264,1268,1379,1383,1411,1415,1482,1486,1493,1505,1509,1512,1516,1530],[11,1169,1171],{"id":1170},"le-xvb-est-toujours-autorisé-le-vob-sous-conditions","Le XVB est toujours autorisé — le VOB sous conditions",[16,1173,1174,1175,1178,1179,1182],{},"L'installation électrique dans la salle de bain est soumise à des règles particulières en Belgique. La règle de base : le ",[20,1176,1177],{},"câble XVB"," (câble sous gaine) est autorisé dans toutes les zones de la salle de bain. Le ",[20,1180,1181],{},"fil VOB en conduit"," (Preflex) est soumis à des restrictions — notamment dans les cloisons creuses.",[11,1184,1186],{"id":1185},"les-zones-rgie-de-la-salle-de-bain","Les zones RGIE de la salle de bain",[16,1188,1189,1190,1193],{},"Le RGIE définit ",[20,1191,1192],{},"trois zones"," autour de la baignoire et de la douche : zone 0, zone 1, zone 2 (uniquement pour les baignoires) et la zone hors périmètre (art. 7.1.3.2).",[40,1195,1196,1208],{},[43,1197,1198],{},[46,1199,1200,1202,1205],{},[49,1201,51],{},[49,1203,1204],{},"Périmètre",[49,1206,1207],{},"Installation autorisée",[59,1209,1210,1222,1234],{},[46,1211,1212,1216,1219],{},[64,1213,1214],{},[20,1215,138],{},[64,1217,1218],{},"Intérieur de la baignoire\u002Fdouche",[64,1220,1221],{},"TBTS ≤ 12V uniquement, IPX7",[46,1223,1224,1228,1231],{},[64,1225,1226],{},[20,1227,141],{},[64,1229,1230],{},"Verticalement au-dessus de la zone 0, jusqu'à 2,25 m de hauteur",[64,1232,1233],{},"Appareils fixes ≥ IPX4 ; prises TBTS et interrupteurs TBTS autorisés (art. 7.1.5.2c n° 2 et 4)",[46,1235,1236,1240,1246],{},[64,1237,1238],{},[20,1239,144],{},[64,1241,1242,1243],{},"60 cm autour de la zone 1 — ",[20,1244,1245],{},"uniquement pour les baignoires",[64,1247,1248],{},"Prises avec différentiel 30mA autorisées, appareils ≥ IPX4",[105,1250,1251],{},[16,1252,1253,1256,1257,1260],{},[20,1254,1255],{},"Important :"," La zone 2 n'est ",[20,1258,1259],{},"pas définie"," pour les douches (art. 7.1.3.2 n° 3b). Pour les douches, la zone 1 est directement suivie de la zone hors périmètre.",[16,1262,1263],{},"En dehors de ces zones, les règles d'installation normales s'appliquent.",[11,1265,1267],{"id":1266},"types-de-câbles-et-leur-admissibilité","Types de câbles et leur admissibilité",[40,1269,1270,1289],{},[43,1271,1272],{},[46,1273,1274,1277,1280,1282,1284,1286],{},[49,1275,1276],{},"Type de câble",[49,1278,1279],{},"Classe CPR",[49,1281,138],{},[49,1283,141],{},[49,1285,144],{},[49,1287,1288],{},"Hors zones",[59,1290,1291,1309,1326,1343,1362],{},[46,1292,1293,1297,1299,1302,1305,1307],{},[64,1294,1295],{},[20,1296,156],{},[64,1298,159],{},[64,1300,1301],{},"Non",[64,1303,1304],{},"Oui",[64,1306,1304],{},[64,1308,1304],{},[46,1310,1311,1315,1317,1319,1322,1324],{},[64,1312,1313],{},[20,1314,176],{},[64,1316,159],{},[64,1318,1301],{},[64,1320,1321],{},"Oui (éclairage)",[64,1323,1304],{},[64,1325,1304],{},[46,1327,1328,1333,1335,1337,1339,1341],{},[64,1329,1330],{},[20,1331,1332],{},"VOB en Preflex gris",[64,1334,197],{},[64,1336,1301],{},[64,1338,1304],{},[64,1340,1304],{},[64,1342,1304],{},[46,1344,1345,1350,1352,1354,1357,1360],{},[64,1346,1347],{},[20,1348,1349],{},"VOB en Preflex vert",[64,1351,197],{},[64,1353,1301],{},[64,1355,1356],{},"Non (cloison creuse)",[64,1358,1359],{},"Restreint",[64,1361,1304],{},[46,1363,1364,1369,1371,1373,1375,1377],{},[64,1365,1366],{},[20,1367,1368],{},"H07Z1-U (sans halogène)",[64,1370,159],{},[64,1372,1301],{},[64,1374,1304],{},[64,1376,1304],{},[64,1378,1304],{},[243,1380,1382],{"id":1381},"notes-importantes-sur-les-types-de-câbles","Notes importantes sur les types de câbles",[248,1384,1385,1390,1400,1406],{},[251,1386,1387,1389],{},[20,1388,255],{}," (câble sous gaine) : Toujours le choix sûr. Adapté pour l'encastrement, le montage en saillie et les chemins de câbles.",[251,1391,1392,1395,1396,1399],{},[20,1393,1394],{},"Preflex gris"," (conduit standard avec VOB pré-tiré) : Autorisé dans les murs massifs. ",[20,1397,1398],{},"Interdit"," dans les cloisons creuses et faux plafonds.",[251,1401,1402,1405],{},[20,1403,1404],{},"Preflex Safe (vert)"," : Dans les murs massifs, le Preflex Safe (Cca) est autorisé même en zone 1. La restriction concerne les cloisons creuses (droogbouw), pas la zone elle-même.",[251,1407,1408,1410],{},[20,1409,277],{}," : Fil sans halogène, particulièrement recommandé pour les zones sensibles. Note : le H07Z1-U en tant que fil individuel n'a pas de classe CPR Cca inhérente — la classe se réfère au système de câblage (fil + conduit). Le H07Z1-U en Preflex Safe atteint Cca.",[11,1412,1414],{"id":1413},"tableau-des-sections","Tableau des sections",[40,1416,1417,1430],{},[43,1418,1419],{},[46,1420,1421,1424,1427],{},[49,1422,1423],{},"Utilisation",[49,1425,1426],{},"Section min.",[49,1428,1429],{},"Disjoncteur",[59,1431,1432,1442,1452,1462,1471],{},[46,1433,1434,1437,1439],{},[64,1435,1436],{},"Éclairage",[64,1438,307],{},[64,1440,1441],{},"10A ou 16A",[46,1443,1444,1447,1449],{},[64,1445,1446],{},"Prises",[64,1448,318],{},[64,1450,1451],{},"16A ou 20A",[46,1453,1454,1457,1459],{},[64,1455,1456],{},"Lave-linge \u002F sèche-linge",[64,1458,318],{},[64,1460,1461],{},"16A (circuit dédié)",[46,1463,1464,1467,1469],{},[64,1465,1466],{},"Chauffe-eau électrique (sous évier, ≤ 2 kW)",[64,1468,318],{},[64,1470,341],{},[46,1472,1473,1476,1479],{},[64,1474,1475],{},"Chauffe-eau instantané (18–27 kW)",[64,1477,1478],{},"6 mm² (32A) ou 10 mm² (40A, triphasé)",[64,1480,1481],{},"32A ou 40A",[11,1483,1485],{"id":1484},"la-protection-différentielle-30ma-est-obligatoire","La protection différentielle 30mA est obligatoire",[16,1487,1488,1489,1492],{},"Selon l'article 7.1.4.3 du RGIE, ",[20,1490,1491],{},"tous les circuits de la salle de bain"," doivent être protégés par un différentiel 30mA — sans exception. Cela s'applique aussi bien à l'éclairage qu'aux prises et aux appareils fixes.",[105,1494,1495],{},[16,1496,1497,1500,1501,1504],{},[20,1498,1499],{},"Attention"," : Même les circuits qui ne font que ",[373,1502,1503],{},"traverser"," la salle de bain (par exemple, des câbles vers les combles) doivent respecter les exigences des zones s'ils passent à l'intérieur des zones de protection.",[11,1506,1508],{"id":1507},"liaison-équipotentielle-dans-la-salle-de-bain","Liaison équipotentielle dans la salle de bain",[16,1510,1511],{},"Important : le RGIE (art. 7.1.4.4) exige une liaison équipotentielle supplémentaire dans la salle de bain — toutes les parties métalliques (conduites d'eau, radiateurs, baignoire, tuyaux d'évacuation) doivent être reliées entre elles et à la borne de terre principale par un conducteur de protection. L'absence de liaison équipotentielle est un motif fréquent de non-conformité lors du contrôle.",[11,1513,1515],{"id":1514},"articles-connexes","Articles connexes",[248,1517,1518,1524],{},[251,1519,1520],{},[393,1521,1523],{"href":1522},"\u002Ffr\u002Fblog\u002F30ma-ddr-par-prise","Ai-je besoin d'un différentiel 30mA par prise ?",[251,1525,1526],{},[393,1527,1529],{"href":1528},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique — ce qu'il faut savoir",[16,1531,1532],{},[393,1533,1534],{"href":407},"Planifiez l'électricité de votre salle de bain avec PlanElec — gratuit →",{"title":410,"searchDepth":411,"depth":411,"links":1536},[1537,1538,1539,1542,1543,1544,1545],{"id":1170,"depth":411,"text":1171},{"id":1185,"depth":411,"text":1186},{"id":1266,"depth":411,"text":1267,"children":1540},[1541],{"id":1381,"depth":418,"text":1382},{"id":1413,"depth":411,"text":1414},{"id":1484,"depth":411,"text":1485},{"id":1507,"depth":411,"text":1508},{"id":1514,"depth":411,"text":1515},"Le XVB est toujours autorisé, le VOB en conduit seulement sous conditions. Découvrez quels types de câbles sont autorisés dans chaque zone RGIE.","fr",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.fr",{"title":1165,"description":1546},"cables-salle-de-bain-rgie","blog\u002Fbathroom-cables-arei-zones.fr",[437,438,1554,1151,255,441,442,1555,1556,445,1557,1558,1559,1160,1159,1560,452],"salle de bain","câbles","différentiel","contrôle électrique","installation électrique","Belgique","plan de situation","L_MvtfaVoDtgPwSfXbPjyHTffaIarkqdwoW60DjH-8E",{"id":1563,"title":1564,"articleId":6,"body":1565,"category":423,"date":424,"description":1944,"extension":426,"lastUpdated":424,"locale":1945,"meta":1946,"navigation":429,"path":1947,"publishDate":424,"readTime":431,"refreshInterval":432,"seo":1948,"slug":1949,"stem":1950,"tags":1951,"__hash__":1958},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.nl.md","Welke kabels mag ik gebruiken in de badkamer? (AREI-zones)",{"type":8,"value":1566,"toc":1933},[1567,1571,1582,1586,1593,1648,1660,1663,1667,1777,1781,1809,1813,1880,1884,1891,1903,1907,1910,1914,1928],[11,1568,1570],{"id":1569},"xvb-is-altijd-toegelaten-vob-alleen-onder-voorwaarden","XVB is altijd toegelaten — VOB alleen onder voorwaarden",[16,1572,1573,1574,1577,1578,1581],{},"Bij de elektrische installatie in de badkamer gelden in België bijzondere voorschriften. De belangrijkste vuistregel: ",[20,1575,1576],{},"XVB-kabel"," (mantelleiding) is in alle badkamerzones toegelaten. ",[20,1579,1580],{},"VOB-draad in buis"," (Preflex) is aan beperkingen onderworpen — vooral in holle wanden.",[11,1583,1585],{"id":1584},"de-arei-badkamerzones","De AREI-badkamerzones",[16,1587,1588,1589,1592],{},"Het AREI definieert ",[20,1590,1591],{},"drie zones"," rond bad en douche: Zone 0, Zone 1, Zone 2 (alleen bij badkuipen) en het gebied buiten de zones (Art. 7.1.3.2).",[40,1594,1595,1607],{},[43,1596,1597],{},[46,1598,1599,1601,1604],{},[49,1600,51],{},[49,1602,1603],{},"Gebied",[49,1605,1606],{},"Toegelaten installatie",[59,1608,1609,1621,1633],{},[46,1610,1611,1615,1618],{},[64,1612,1613],{},[20,1614,138],{},[64,1616,1617],{},"Binnenkant van het bad\u002Fde douche",[64,1619,1620],{},"Alleen ZLVS ≤ 12V, IPX7",[46,1622,1623,1627,1630],{},[64,1624,1625],{},[20,1626,141],{},[64,1628,1629],{},"Loodrecht boven zone 0, tot 2,25 m hoogte",[64,1631,1632],{},"Vast aangesloten toestellen ≥ IPX4; ZLVS-stopcontacten en ZLVS-schakelaars toegelaten (Art. 7.1.5.2c Nr. 2 en 4)",[46,1634,1635,1639,1645],{},[64,1636,1637],{},[20,1638,144],{},[64,1640,1641,1642],{},"60 cm rond zone 1 — ",[20,1643,1644],{},"alleen bij badkuipen",[64,1646,1647],{},"Stopcontacten met 30mA differentieel toegelaten, toestellen ≥ IPX4",[105,1649,1650],{},[16,1651,1652,1655,1656,1659],{},[20,1653,1654],{},"Belangrijk:"," Zone 2 is voor douches ",[20,1657,1658],{},"niet gedefinieerd"," (Art. 7.1.3.2 Nr. 3b). Bij douches volgt op zone 1 direct het gebied buiten de zones.",[16,1661,1662],{},"Buiten deze zones gelden de normale installatieregels.",[11,1664,1666],{"id":1665},"kabeltypes-en-hun-toelaatbaarheid","Kabeltypes en hun toelaatbaarheid",[40,1668,1669,1688],{},[43,1670,1671],{},[46,1672,1673,1676,1679,1681,1683,1685],{},[49,1674,1675],{},"Kabeltype",[49,1677,1678],{},"CPR-klasse",[49,1680,138],{},[49,1682,141],{},[49,1684,144],{},[49,1686,1687],{},"Buiten zones",[59,1689,1690,1707,1724,1741,1760],{},[46,1691,1692,1696,1698,1701,1703,1705],{},[64,1693,1694],{},[20,1695,156],{},[64,1697,159],{},[64,1699,1700],{},"Nee",[64,1702,165],{},[64,1704,165],{},[64,1706,165],{},[46,1708,1709,1713,1715,1717,1720,1722],{},[64,1710,1711],{},[20,1712,176],{},[64,1714,159],{},[64,1716,1700],{},[64,1718,1719],{},"Ja (verlichting)",[64,1721,165],{},[64,1723,165],{},[46,1725,1726,1731,1733,1735,1737,1739],{},[64,1727,1728],{},[20,1729,1730],{},"VOB in grijze Preflex",[64,1732,197],{},[64,1734,1700],{},[64,1736,165],{},[64,1738,165],{},[64,1740,165],{},[46,1742,1743,1748,1750,1752,1755,1758],{},[64,1744,1745],{},[20,1746,1747],{},"VOB in groene Preflex",[64,1749,197],{},[64,1751,1700],{},[64,1753,1754],{},"Nee (holle wand)",[64,1756,1757],{},"Beperkt",[64,1759,165],{},[46,1761,1762,1767,1769,1771,1773,1775],{},[64,1763,1764],{},[20,1765,1766],{},"H07Z1-U (halogeenvrij)",[64,1768,159],{},[64,1770,1700],{},[64,1772,165],{},[64,1774,165],{},[64,1776,165],{},[243,1778,1780],{"id":1779},"belangrijke-opmerkingen-bij-de-kabeltypes","Belangrijke opmerkingen bij de kabeltypes",[248,1782,1783,1788,1798,1804],{},[251,1784,1785,1787],{},[20,1786,255],{}," (mantelleiding): Altijd de veilige keuze. Geschikt voor inbouw, opbouw en in kabelgoten.",[251,1789,1790,1793,1794,1797],{},[20,1791,1792],{},"Grijze Preflex"," (standaard buis met voorgetrokken VOB): Toegelaten in massieve wanden. ",[20,1795,1796],{},"Niet"," in holle wanden of verlaagde plafonds.",[251,1799,1800,1803],{},[20,1801,1802],{},"Preflex Safe (groen)",": In massieve wanden is Preflex Safe (Cca) ook in zone 1 toegelaten. De beperking geldt voor holle wanden (droogbouw), niet voor de zone zelf.",[251,1805,1806,1808],{},[20,1807,277],{},": Halogeenvrije draad, vooral aanbevolen voor gevoelige zones. Let op: H07Z1-U als enkeldraad heeft geen inherente CPR-klasse Cca — de klasse verwijst naar het kabelsysteem (draad + buis). H07Z1-U in Preflex Safe bereikt Cca.",[11,1810,1812],{"id":1811},"doorsnede-tabel","Doorsnede-tabel",[40,1814,1815,1828],{},[43,1816,1817],{},[46,1818,1819,1822,1825],{},[49,1820,1821],{},"Gebruik",[49,1823,1824],{},"Min. doorsnede",[49,1826,1827],{},"Automaat",[59,1829,1830,1840,1850,1860,1869],{},[46,1831,1832,1835,1837],{},[64,1833,1834],{},"Verlichting",[64,1836,307],{},[64,1838,1839],{},"10A of 16A",[46,1841,1842,1845,1847],{},[64,1843,1844],{},"Stopcontacten",[64,1846,318],{},[64,1848,1849],{},"16A of 20A",[46,1851,1852,1855,1857],{},[64,1853,1854],{},"Wasmachine \u002F droogkast",[64,1856,318],{},[64,1858,1859],{},"16A (eigen kring)",[46,1861,1862,1865,1867],{},[64,1863,1864],{},"Elektrische boiler (onder aanrecht, ≤ 2 kW)",[64,1866,318],{},[64,1868,341],{},[46,1870,1871,1874,1877],{},[64,1872,1873],{},"Elektrische doorstromer (18–27 kW)",[64,1875,1876],{},"6 mm² (32A) of 10 mm² (40A, driefasig)",[64,1878,1879],{},"32A of 40A",[11,1881,1883],{"id":1882},"_30ma-differentieelbescherming-is-verplicht","30mA differentieelbescherming is verplicht",[16,1885,1886,1887,1890],{},"Volgens AREI Art. 7.1.4.3 moeten ",[20,1888,1889],{},"alle kringen in de badkamer"," beschermd zijn door een 30mA differentieel — zonder uitzondering. Dit geldt voor verlichting, stopcontacten en vast aangesloten toestellen.",[105,1892,1893],{},[16,1894,1895,1898,1899,1902],{},[20,1896,1897],{},"Let op",": Ook kringen die alleen maar ",[373,1900,1901],{},"door"," de badkamer lopen (bijv. kabels naar de zolder) moeten aan de zone-eisen voldoen als ze binnen de beschermingszones lopen.",[11,1904,1906],{"id":1905},"potentiaalvereffening-in-de-badkamer","Potentiaalvereffening in de badkamer",[16,1908,1909],{},"Belangrijk: Het AREI (Art. 7.1.4.4) vereist een bijkomende potentiaalvereffening in de badkamer — alle metalen delen (waterleidingen, radiatoren, badkuip, afvoerleidingen) moeten via een beschermingsleider onderling en met de hoofdaardingsklem verbonden worden. Ontbrekende potentiaalvereffening is een veelvoorkomende reden voor afkeuring bij de keuring.",[11,1911,1913],{"id":1912},"gerelateerde-artikelen","Gerelateerde artikelen",[248,1915,1916,1922],{},[251,1917,1918],{},[393,1919,1921],{"href":1920},"\u002Fblog\u002F30ma-aardlek-per-stopcontact","Heb ik een 30mA differentieel nodig per stopcontact?",[251,1923,1924],{},[393,1925,1927],{"href":1926},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België — wat u moet weten",[16,1929,1930],{},[393,1931,1932],{"href":407},"Plan uw badkamerelektriciteit met PlanElec — gratis →",{"title":410,"searchDepth":411,"depth":411,"links":1934},[1935,1936,1937,1940,1941,1942,1943],{"id":1569,"depth":411,"text":1570},{"id":1584,"depth":411,"text":1585},{"id":1665,"depth":411,"text":1666,"children":1938},[1939],{"id":1779,"depth":418,"text":1780},{"id":1811,"depth":411,"text":1812},{"id":1882,"depth":411,"text":1883},{"id":1905,"depth":411,"text":1906},{"id":1912,"depth":411,"text":1913},"XVB is altijd toegelaten, VOB in buis alleen onder voorwaarden. Ontdek welke kabeltypes zijn toegestaan in elke AREI-zone en waar u op moet letten.","nl",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.nl",{"title":1564,"description":1944},"badkamer-kabels-arei-zones","blog\u002Fbathroom-cables-arei-zones.nl",[437,438,1952,1151,255,441,442,1953,1954,445,1155,1955,1956,1159,1957,452],"badkamer","kabels","differentieel","elektrische installatie","België","situatieschema","FGPbM7vnU3id6vpaedLue-WoNAfOres3urO8n7x1Ta8",1775151657950]