[{"data":1,"prerenderedAt":938},["ShallowReactive",2],{"blog-post-de-hauptschalter-pflicht-arei":3,"blog-alternates-main-switch-mandatory":227},{"id":4,"title":5,"articleId":6,"body":7,"category":207,"date":208,"description":209,"extension":210,"lastUpdated":208,"locale":211,"meta":212,"navigation":213,"path":214,"publishDate":208,"readTime":215,"refreshInterval":216,"seo":217,"slug":218,"stem":219,"tags":220,"__hash__":226},"blog\u002Fblog\u002Fmain-switch-mandatory.de.md","Hauptschalter Pflicht: Was schreibt das AREI vor?","main-switch-mandatory",{"type":8,"value":9,"toc":197},"minimark",[10,14,22,27,30,64,68,111,115,118,133,137,144,147,164,168,175,182,186],[11,12,5],"h1",{"id":13},"hauptschalter-pflicht-was-schreibt-das-arei-vor",[15,16,17,21],"p",{},[18,19,20],"strong",{},"Ja, ein Hauptschalter ist in Belgien Pflicht."," Laut AREI Art. 5.3.5.1b muss an jeder Haupt-Verteiler- und Schaltgerätekombination ein Haupt-Lasttrennschalter angebracht werden, der die gleichzeitige Abschaltung aller Außenleiter und gegebenenfalls des Neutralleiters ermöglicht. Der übliche Mindestwert für ein Einfamilienhaus ist 40 A (entspricht dem Anschlusswert). Das AREI schreibt in hauswirtschaftlichen Anlagen eine Nennstromstärke von mindestens 40 A vor (Art. 5.3.5.1b); allgemein liegt das Minimum bei 25 A. In der Praxis wird ein Lasttrennschalter (interrupteur-sectionneur) als Hauptschalter verwendet. Anders als ein reiner Trennschalter darf dieser auch unter Last geschaltet werden.",[23,24,26],"h2",{"id":25},"anforderungen-an-den-hauptschalter","Anforderungen an den Hauptschalter",[15,28,29],{},"Der Hauptschalter muss folgende Bedingungen erfüllen:",[31,32,33,40,46,52,58],"ul",{},[34,35,36,39],"li",{},[18,37,38],{},"Allpolig:"," Bei einphasigem Anschluss 2-polig (Phase + Neutral), bei dreiphasigem Anschluss 4-polig (3 Phasen + Neutral)",[34,41,42,45],{},[18,43,44],{},"Nennstrom mindestens 40 A"," in hauswirtschaftlichen Anlagen (Art. 5.3.5.1b), angepasst an die jeweilige Anlage",[34,47,48,51],{},[18,49,50],{},"Gesamte Installation freischalten:"," Ein einziger Griff muss alle aktiven Leiter trennen",[34,53,54,57],{},[18,55,56],{},"Leicht zugänglich:"," Betätigungshöhe max. 1,80 m (Praxiswert der Kontrollorganismen — das AREI fordert 'leicht zugänglich und von der Wohnfläche aus erreichbar', nennt aber keine exakte Höhe)",[34,59,60,63],{},[18,61,62],{},"Am Eingang der Installation:"," Vor dem Verteilerkasten, als erstes Schaltorgan nach dem Zähler",[23,65,67],{"id":66},"arei-artikel","AREI-Artikel",[69,70,71,84],"table",{},[72,73,74],"thead",{},[75,76,77,81],"tr",{},[78,79,80],"th",{},"AREI Artikel",[78,82,83],{},"Anforderung",[85,86,87,96,103],"tbody",{},[75,88,89,93],{},[90,91,92],"td",{},"Art. 5.3.5.1b",[90,94,95],{},"Haupt-Lasttrennschalter ist Pflicht, allpolig, an der Haupt-Verteiler- und Schaltgerätekombination",[75,97,98,100],{},[90,99,92],{},[90,101,102],{},"Nennstrom mindestens 40 A in hauswirtschaftlichen Anlagen, angepasst an die jeweilige Anlage",[75,104,105,108],{},[90,106,107],{},"Art. 5.3.5.1c",[90,109,110],{},"Verteiler- und Schaltgerätekombinationen müssen leicht zugänglich und bedienbar sein",[23,112,114],{"id":113},"warum-ist-der-hauptschalter-so-wichtig","Warum ist der Hauptschalter so wichtig?",[15,116,117],{},"Der Hauptschalter erfüllt zwei zentrale Funktionen:",[119,120,121,127],"ol",{},[34,122,123,126],{},[18,124,125],{},"Not-Abschaltung:"," Im Notfall (Brand, Überschwemmung, Stromunfall) muss jeder Bewohner die gesamte Installation mit einem Griff abschalten können — auch ohne Elektrofachkenntnisse.",[34,128,129,132],{},[18,130,131],{},"Wartung:"," Für Arbeiten an der Elektroinstallation muss die gesamte Anlage sicher freigeschaltet werden können.",[23,134,136],{"id":135},"häufiger-keurings-mangel","Häufiger Keurings-Mangel",[15,138,139,140,143],{},"Der fehlende oder falsch dimensionierte Hauptschalter ist einer der ",[18,141,142],{},"häufigsten Mängel bei der Elektrokontrolle (Keuring)"," in Belgien. Besonders in Altinstallationen fehlt er oft vollständig, oder es ist nur ein einpoliger Schalter verbaut, der den Neutralleiter nicht trennt.",[15,145,146],{},"Typische Mängel:",[31,148,149,152,155,158,161],{},[34,150,151],{},"Kein Hauptschalter vorhanden",[34,153,154],{},"Nur einpolig statt allpolig",[34,156,157],{},"Nennstrom unter 40 A in hauswirtschaftlicher Anlage",[34,159,160],{},"Zu hoch montiert (nicht leicht zugänglich)",[34,162,163],{},"Nicht leicht zugänglich (hinter Möbeln, in verschlossenem Raum)",[23,165,167],{"id":166},"hauptschalter-vs-hauptsicherung","Hauptschalter vs. Hauptsicherung",[15,169,170,171,174],{},"Der Hauptschalter ist ",[18,172,173],{},"kein Sicherungsautomat"," — er hat keine Schutzfunktion gegen Überstrom. Er dient ausschließlich als Trennschalter. Der Überstromschutz wird durch den Netzbetreiber (Sicherung vor dem Zähler) und die nachgeschalteten Sicherungsautomaten im Verteiler gewährleistet.",[15,176,177,178,181],{},"Allerdings kann ein ",[18,179,180],{},"Hauptsicherungsautomat"," (z. B. 40 A) beide Funktionen vereinen: Trennen und Überstromschutz.",[23,183,185],{"id":184},"verwandte-artikel","Verwandte Artikel",[15,187,188,189,196],{},"Planen Sie Ihren Verteiler normgerecht mit ",[190,191,195],"a",{"href":192,"rel":193},"https:\u002F\u002Fwww.planelec.be",[194],"nofollow","PlanElec"," — Hauptschalter-Prüfung automatisch integriert.",{"title":198,"searchDepth":199,"depth":199,"links":200},"",2,[201,202,203,204,205,206],{"id":25,"depth":199,"text":26},{"id":66,"depth":199,"text":67},{"id":113,"depth":199,"text":114},{"id":135,"depth":199,"text":136},{"id":166,"depth":199,"text":167},{"id":184,"depth":199,"text":185},"faq","2026-03-23","Warum der Hauptschalter in Belgien Pflicht ist und welche Anforderungen das AREI Art. 5.3.5.1b stellt.","md","de",{},true,"\u002Fblog\u002Fmain-switch-mandatory.de","4 min",12,{"title":5,"description":209},"hauptschalter-pflicht-arei","blog\u002Fmain-switch-mandatory.de",[221,222,223,224,225],"hauptschalter","arei","pflicht","verteiler","keuring","VutUyOHVybMc96trVRDye9kPOYEVySgpp_mrlbTJIHg",[228,357,551,746],{"id":4,"title":5,"articleId":6,"body":229,"category":207,"date":208,"description":209,"extension":210,"lastUpdated":208,"locale":211,"meta":354,"navigation":213,"path":214,"publishDate":208,"readTime":215,"refreshInterval":216,"seo":355,"slug":218,"stem":219,"tags":356,"__hash__":226},{"type":8,"value":230,"toc":346},[231,233,237,239,241,263,265,295,297,299,309,311,315,317,329,331,335,339,341],[11,232,5],{"id":13},[15,234,235,21],{},[18,236,20],{},[23,238,26],{"id":25},[15,240,29],{},[31,242,243,247,251,255,259],{},[34,244,245,39],{},[18,246,38],{},[34,248,249,45],{},[18,250,44],{},[34,252,253,51],{},[18,254,50],{},[34,256,257,57],{},[18,258,56],{},[34,260,261,63],{},[18,262,62],{},[23,264,67],{"id":66},[69,266,267,275],{},[72,268,269],{},[75,270,271,273],{},[78,272,80],{},[78,274,83],{},[85,276,277,283,289],{},[75,278,279,281],{},[90,280,92],{},[90,282,95],{},[75,284,285,287],{},[90,286,92],{},[90,288,102],{},[75,290,291,293],{},[90,292,107],{},[90,294,110],{},[23,296,114],{"id":113},[15,298,117],{},[119,300,301,305],{},[34,302,303,126],{},[18,304,125],{},[34,306,307,132],{},[18,308,131],{},[23,310,136],{"id":135},[15,312,139,313,143],{},[18,314,142],{},[15,316,146],{},[31,318,319,321,323,325,327],{},[34,320,151],{},[34,322,154],{},[34,324,157],{},[34,326,160],{},[34,328,163],{},[23,330,167],{"id":166},[15,332,170,333,174],{},[18,334,173],{},[15,336,177,337,181],{},[18,338,180],{},[23,340,185],{"id":184},[15,342,188,343,196],{},[190,344,195],{"href":192,"rel":345},[194],{"title":198,"searchDepth":199,"depth":199,"links":347},[348,349,350,351,352,353],{"id":25,"depth":199,"text":26},{"id":66,"depth":199,"text":67},{"id":113,"depth":199,"text":114},{"id":135,"depth":199,"text":136},{"id":166,"depth":199,"text":167},{"id":184,"depth":199,"text":185},{},{"title":5,"description":209},[221,222,223,224,225],{"id":358,"title":359,"articleId":6,"body":360,"category":207,"date":208,"description":538,"extension":210,"lastUpdated":208,"locale":539,"meta":540,"navigation":213,"path":541,"publishDate":208,"readTime":215,"refreshInterval":216,"seo":542,"slug":543,"stem":544,"tags":545,"__hash__":550},"blog\u002Fblog\u002Fmain-switch-mandatory.en.md","Main Switch Mandatory: What Does the AREI Require?",{"type":8,"value":361,"toc":530},[362,365,371,375,378,410,414,449,453,456,470,474,481,484,501,505,512,519,523],[11,363,359],{"id":364},"main-switch-mandatory-what-does-the-arei-require",[15,366,367,370],{},[18,368,369],{},"Yes, a main switch is mandatory in Belgium."," According to AREI Art. 5.3.5.1b, every main distribution and switchgear assembly must have an all-pole main load-break switch capable of simultaneously disconnecting all line conductors and, where applicable, the neutral conductor. For domestic installations, the AREI requires a rated current of at least 40 A (Art. 5.3.5.1b); the general minimum is 25 A. In practice, a load-break switch (interrupteur-sectionneur) is used as the main switch. Unlike a plain isolator, it may be switched under load.",[23,372,374],{"id":373},"requirements-for-the-main-switch","Requirements for the Main Switch",[15,376,377],{},"The main switch must meet the following conditions:",[31,379,380,386,392,398,404],{},[34,381,382,385],{},[18,383,384],{},"All-pole:"," For single-phase connections, 2-pole (phase + neutral); for three-phase connections, 4-pole (3 phases + neutral)",[34,387,388,391],{},[18,389,390],{},"Rated current at least 40 A"," for domestic installations (Art. 5.3.5.1b), matched to the specific installation",[34,393,394,397],{},[18,395,396],{},"Disconnect the entire installation:"," A single operation must separate all active conductors",[34,399,400,403],{},[18,401,402],{},"Easily accessible:"," Max. 1.80 m operating height (practical guideline from inspection bodies — the AREI requires 'easily accessible and reachable from the living area' but does not specify an exact height)",[34,405,406,409],{},[18,407,408],{},"At the entrance of the installation:"," Before the distribution board, as the first switching device after the meter",[23,411,413],{"id":412},"arei-articles","AREI Articles",[69,415,416,426],{},[72,417,418],{},[75,419,420,423],{},[78,421,422],{},"AREI Article",[78,424,425],{},"Requirement",[85,427,428,435,442],{},[75,429,430,432],{},[90,431,92],{},[90,433,434],{},"Main load-break switch is mandatory, all-pole, at the main distribution and switchgear assembly",[75,436,437,439],{},[90,438,92],{},[90,440,441],{},"Rated current at least 40 A for domestic installations, matched to the specific installation",[75,443,444,446],{},[90,445,107],{},[90,447,448],{},"Distribution and switchgear assemblies must be easily accessible and operable",[23,450,452],{"id":451},"why-is-the-main-switch-so-important","Why Is the Main Switch So Important?",[15,454,455],{},"The main switch fulfils two central functions:",[119,457,458,464],{},[34,459,460,463],{},[18,461,462],{},"Emergency disconnection:"," In an emergency (fire, flooding, electric shock), any occupant must be able to disconnect the entire installation with a single action — even without electrical expertise.",[34,465,466,469],{},[18,467,468],{},"Maintenance:"," For work on the electrical installation, the entire system must be safely disconnectable.",[23,471,473],{"id":472},"common-inspection-deficiency","Common Inspection Deficiency",[15,475,476,477,480],{},"A missing or incorrectly rated main switch is one of the ",[18,478,479],{},"most common deficiencies found during electrical inspection (keuring)"," in Belgium. Especially in older installations, it is often entirely absent, or only a single-pole switch is installed that does not disconnect the neutral.",[15,482,483],{},"Typical deficiencies:",[31,485,486,489,492,495,498],{},[34,487,488],{},"No main switch present",[34,490,491],{},"Single-pole instead of all-pole",[34,493,494],{},"Rated current below 40 A in a domestic installation",[34,496,497],{},"Mounted too high (not easily accessible)",[34,499,500],{},"Not easily accessible (behind furniture, in a locked room)",[23,502,504],{"id":503},"main-switch-vs-main-circuit-breaker","Main Switch vs. Main Circuit Breaker",[15,506,507,508,511],{},"The main switch is ",[18,509,510],{},"not a circuit breaker"," — it has no overcurrent protection function. It serves exclusively as a disconnector. Overcurrent protection is provided by the grid operator (fuse before the meter) and the downstream circuit breakers in the distribution board.",[15,513,514,515,518],{},"However, a ",[18,516,517],{},"main circuit breaker"," (e.g., 40 A) can combine both functions: disconnection and overcurrent protection.",[23,520,522],{"id":521},"related-articles","Related Articles",[15,524,525,526,529],{},"Plan your distribution board to code with ",[190,527,195],{"href":192,"rel":528},[194]," — main switch verification automatically integrated.",{"title":198,"searchDepth":199,"depth":199,"links":531},[532,533,534,535,536,537],{"id":373,"depth":199,"text":374},{"id":412,"depth":199,"text":413},{"id":451,"depth":199,"text":452},{"id":472,"depth":199,"text":473},{"id":503,"depth":199,"text":504},{"id":521,"depth":199,"text":522},"Why a main switch is mandatory in Belgium and what requirements AREI Art. 5.3.5.1b imposes.","en",{},"\u002Fblog\u002Fmain-switch-mandatory.en",{"title":359,"description":538},"main-switch-mandatory-arei","blog\u002Fmain-switch-mandatory.en",[546,222,547,548,549],"main-switch","mandatory","distribution-board","inspection","9yhxuZFtpBUE3zuo1_vlv1ThJhmIcg7aX9JK72gQH3M",{"id":552,"title":553,"articleId":6,"body":554,"category":207,"date":208,"description":732,"extension":210,"lastUpdated":208,"locale":733,"meta":734,"navigation":213,"path":735,"publishDate":208,"readTime":215,"refreshInterval":216,"seo":736,"slug":737,"stem":738,"tags":739,"__hash__":745},"blog\u002Fblog\u002Fmain-switch-mandatory.fr.md","Interrupteur général obligatoire : Que prescrit le RGIE ?",{"type":8,"value":555,"toc":724},[556,559,565,569,572,604,608,643,647,650,664,668,675,678,695,699,706,713,717],[11,557,553],{"id":558},"interrupteur-général-obligatoire-que-prescrit-le-rgie",[15,560,561,564],{},[18,562,563],{},"Oui, un interrupteur général est obligatoire en Belgique."," Selon le RGIE Art. 5.3.5.1b, chaque ensemble d'appareillage principal doit disposer d'un interrupteur-sectionneur principal omnipolaire permettant la coupure simultanée de tous les conducteurs actifs et éventuellement du neutre. Le RGIE prescrit un courant nominal d'au moins 40 A pour les installations domestiques (Art. 5.3.5.1b) ; le minimum général est de 25 A. En pratique, un interrupteur-sectionneur est utilisé comme interrupteur principal. Contrairement à un simple sectionneur, il peut être manoeuvré en charge.",[23,566,568],{"id":567},"exigences-pour-linterrupteur-général","Exigences pour l'interrupteur général",[15,570,571],{},"L'interrupteur général doit satisfaire les conditions suivantes :",[31,573,574,580,586,592,598],{},[34,575,576,579],{},[18,577,578],{},"Omnipolaire :"," Pour un raccordement monophasé, 2 pôles (phase + neutre) ; pour un raccordement triphasé, 4 pôles (3 phases + neutre)",[34,581,582,585],{},[18,583,584],{},"Courant nominal au moins 40 A"," pour les installations domestiques (Art. 5.3.5.1b), adapté à l'installation concernée",[34,587,588,591],{},[18,589,590],{},"Couper toute l'installation :"," Une seule manoeuvre doit séparer tous les conducteurs actifs",[34,593,594,597],{},[18,595,596],{},"Facilement accessible :"," Hauteur de manoeuvre max. 1,80 m (valeur pratique des organismes de contrôle — le RGIE exige 'facilement accessible et atteignable depuis la surface habitable', sans préciser de hauteur exacte)",[34,599,600,603],{},[18,601,602],{},"À l'entrée de l'installation :"," Avant le tableau de distribution, comme premier organe de coupure après le compteur",[23,605,607],{"id":606},"articles-rgie","Articles RGIE",[69,609,610,620],{},[72,611,612],{},[75,613,614,617],{},[78,615,616],{},"Article RGIE",[78,618,619],{},"Exigence",[85,621,622,629,636],{},[75,623,624,626],{},[90,625,92],{},[90,627,628],{},"Interrupteur-sectionneur principal obligatoire, omnipolaire, sur l'ensemble d'appareillage principal",[75,630,631,633],{},[90,632,92],{},[90,634,635],{},"Courant nominal au moins 40 A pour les installations domestiques, adapté à l'installation concernée",[75,637,638,640],{},[90,639,107],{},[90,641,642],{},"Les ensembles d'appareillage doivent être facilement accessibles et manoeuvrables",[23,644,646],{"id":645},"pourquoi-linterrupteur-général-est-il-si-important","Pourquoi l'interrupteur général est-il si important ?",[15,648,649],{},"L'interrupteur général remplit deux fonctions centrales :",[119,651,652,658],{},[34,653,654,657],{},[18,655,656],{},"Coupure d'urgence :"," En cas d'urgence (incendie, inondation, électrocution), tout occupant doit pouvoir couper l'ensemble de l'installation d'une seule manoeuvre — même sans connaissances en électricité.",[34,659,660,663],{},[18,661,662],{},"Maintenance :"," Pour les travaux sur l'installation électrique, l'ensemble de l'installation doit pouvoir être mise hors tension en toute sécurité.",[23,665,667],{"id":666},"défaut-fréquent-au-contrôle","Défaut fréquent au contrôle",[15,669,670,671,674],{},"L'interrupteur général absent ou mal dimensionné est l'un des ",[18,672,673],{},"défauts les plus fréquents lors du contrôle électrique"," en Belgique. Surtout dans les anciennes installations, il est souvent totalement absent, ou seul un interrupteur unipolaire est installé, qui ne coupe pas le neutre.",[15,676,677],{},"Défauts typiques :",[31,679,680,683,686,689,692],{},[34,681,682],{},"Aucun interrupteur général présent",[34,684,685],{},"Unipolaire au lieu d'omnipolaire",[34,687,688],{},"Courant nominal inférieur à 40 A dans une installation domestique",[34,690,691],{},"Monté trop haut (pas facilement accessible)",[34,693,694],{},"Pas facilement accessible (derrière des meubles, dans un local fermé)",[23,696,698],{"id":697},"interrupteur-général-vs-disjoncteur-principal","Interrupteur général vs. disjoncteur principal",[15,700,701,702,705],{},"L'interrupteur général n'est ",[18,703,704],{},"pas un disjoncteur"," — il n'a pas de fonction de protection contre les surintensités. Il sert exclusivement d'interrupteur de sectionnement. La protection contre les surintensités est assurée par le gestionnaire de réseau (fusible avant le compteur) et les disjoncteurs en aval dans le tableau.",[15,707,708,709,712],{},"Cependant, un ",[18,710,711],{},"disjoncteur principal"," (p.ex. 40 A) peut combiner les deux fonctions : sectionnement et protection contre les surintensités.",[23,714,716],{"id":715},"articles-connexes","Articles connexes",[15,718,719,720,723],{},"Planifiez votre tableau conforme aux normes avec ",[190,721,195],{"href":192,"rel":722},[194]," — vérification de l'interrupteur général automatiquement intégrée.",{"title":198,"searchDepth":199,"depth":199,"links":725},[726,727,728,729,730,731],{"id":567,"depth":199,"text":568},{"id":606,"depth":199,"text":607},{"id":645,"depth":199,"text":646},{"id":666,"depth":199,"text":667},{"id":697,"depth":199,"text":698},{"id":715,"depth":199,"text":716},"Pourquoi l'interrupteur général est obligatoire en Belgique et quelles exigences le RGIE Art. 5.3.5.1b impose.","fr",{},"\u002Fblog\u002Fmain-switch-mandatory.fr",{"title":553,"description":732},"interrupteur-general-obligatoire-rgie","blog\u002Fmain-switch-mandatory.fr",[740,741,742,743,744],"interrupteur-general","rgie","obligatoire","tableau","controle","WwDZABX3OLEHpnhF9bA0LastBaPQdqImrdaVscZo0AM",{"id":747,"title":748,"articleId":6,"body":749,"category":207,"date":208,"description":926,"extension":210,"lastUpdated":208,"locale":927,"meta":928,"navigation":213,"path":929,"publishDate":208,"readTime":215,"refreshInterval":216,"seo":930,"slug":931,"stem":932,"tags":933,"__hash__":937},"blog\u002Fblog\u002Fmain-switch-mandatory.nl.md","Hoofdschakelaar verplicht: Wat schrijft het AREI voor?",{"type":8,"value":750,"toc":918},[751,754,760,764,767,799,803,837,841,844,858,862,869,872,889,893,900,907,911],[11,752,748],{"id":753},"hoofdschakelaar-verplicht-wat-schrijft-het-arei-voor",[15,755,756,759],{},[18,757,758],{},"Ja, een hoofdschakelaar is in België verplicht."," Volgens AREI Art. 5.3.5.1b moet elke hoofd-verdeel- en schakelinrichting voorzien zijn van een omnipolaire hoofdlastscheider die de gelijktijdige uitschakeling van alle buitengeleiders en eventueel de nulleider mogelijk maakt. De gebruikelijke minimumwaarde voor een eengezinswoning is 40 A (overeenkomend met het aansluitvermogen). Het AREI schrijft voor huishoudelijke installaties een nominale stroom van minstens 40 A voor (Art. 5.3.5.1b); algemeen ligt het minimum op 25 A. In de praktijk wordt een lastscheider (interrupteur-sectionneur) als hoofdschakelaar gebruikt. In tegenstelling tot een gewone scheidingsschakelaar mag deze ook onder belasting geschakeld worden.",[23,761,763],{"id":762},"eisen-aan-de-hoofdschakelaar","Eisen aan de hoofdschakelaar",[15,765,766],{},"De hoofdschakelaar moet aan de volgende voorwaarden voldoen:",[31,768,769,775,781,787,793],{},[34,770,771,774],{},[18,772,773],{},"Omnipolair:"," Bij eenfasige aansluiting 2-polig (fase + neutraal), bij driefasige aansluiting 4-polig (3 fasen + neutraal)",[34,776,777,780],{},[18,778,779],{},"Nominale stroom minstens 40 A"," voor huishoudelijke installaties (Art. 5.3.5.1b), aangepast aan de betreffende installatie",[34,782,783,786],{},[18,784,785],{},"Volledige installatie vrijschakelen:"," Eén enkele handeling moet alle actieve geleiders scheiden",[34,788,789,792],{},[18,790,791],{},"Gemakkelijk bereikbaar:"," Bedieningshoogte max. 1,80 m (praktijkwaarde van de keuringsorganismen — het AREI eist 'gemakkelijk bereikbaar en vanuit de woonruimte toegankelijk', maar noemt geen exacte hoogte)",[34,794,795,798],{},[18,796,797],{},"Aan de ingang van de installatie:"," Voor de verdeelkast, als eerste schakelapparaat na de meter",[23,800,802],{"id":801},"arei-artikelen","AREI-artikelen",[69,804,805,814],{},[72,806,807],{},[75,808,809,811],{},[78,810,80],{},[78,812,813],{},"Vereiste",[85,815,816,823,830],{},[75,817,818,820],{},[90,819,92],{},[90,821,822],{},"Hoofdlastscheider is verplicht, omnipolair, aan de hoofd-verdeel- en schakelinrichting",[75,824,825,827],{},[90,826,92],{},[90,828,829],{},"Nominale stroom minstens 40 A voor huishoudelijke installaties, aangepast aan de betreffende installatie",[75,831,832,834],{},[90,833,107],{},[90,835,836],{},"Verdeel- en schakelinrichtingen moeten gemakkelijk bereikbaar en bedienbaar zijn",[23,838,840],{"id":839},"waarom-is-de-hoofdschakelaar-zo-belangrijk","Waarom is de hoofdschakelaar zo belangrijk?",[15,842,843],{},"De hoofdschakelaar vervult twee centrale functies:",[119,845,846,852],{},[34,847,848,851],{},[18,849,850],{},"Nooduitschakeling:"," In noodgevallen (brand, overstroming, elektrocutie) moet elke bewoner de volledige installatie met één handeling kunnen uitschakelen — ook zonder elektrotechnische kennis.",[34,853,854,857],{},[18,855,856],{},"Onderhoud:"," Voor werkzaamheden aan de elektro-installatie moet de volledige installatie veilig vrijgeschakeld kunnen worden.",[23,859,861],{"id":860},"veelvoorkomend-keuringsgebrek","Veelvoorkomend keuringsgebrek",[15,863,864,865,868],{},"De ontbrekende of verkeerd gedimensioneerde hoofdschakelaar is een van de ",[18,866,867],{},"meest voorkomende gebreken bij de elektrokeuring"," in België. Vooral bij oudere installaties ontbreekt hij vaak volledig, of er is slechts een éénpolige schakelaar geplaatst die de nulleider niet scheidt.",[15,870,871],{},"Typische gebreken:",[31,873,874,877,880,883,886],{},[34,875,876],{},"Geen hoofdschakelaar aanwezig",[34,878,879],{},"Enkel éénpolig in plaats van omnipolair",[34,881,882],{},"Nominale stroom onder 40 A bij huishoudelijke installatie",[34,884,885],{},"Te hoog gemonteerd (niet gemakkelijk bereikbaar)",[34,887,888],{},"Niet gemakkelijk bereikbaar (achter meubels, in afgesloten ruimte)",[23,890,892],{"id":891},"hoofdschakelaar-vs-hoofdzekering","Hoofdschakelaar vs. hoofdzekering",[15,894,895,896,899],{},"De hoofdschakelaar is ",[18,897,898],{},"geen automatische zekering"," — hij heeft geen beschermingsfunctie tegen overstroom. Hij dient uitsluitend als scheidingsschakelaar. De overstroombeveiliging wordt verzorgd door de netbeheerder (zekering voor de meter) en de automatische zekeringen in de verdeler.",[15,901,902,903,906],{},"Een ",[18,904,905],{},"automatische hoofdschakelaar"," (bv. 40 A) kan echter beide functies combineren: scheiden en overstroombeveiliging.",[23,908,910],{"id":909},"gerelateerde-artikelen","Gerelateerde artikelen",[15,912,913,914,917],{},"Plan uw verdeler conform de normen met ",[190,915,195],{"href":192,"rel":916},[194]," — hoofdschakelaar-controle automatisch inbegrepen.",{"title":198,"searchDepth":199,"depth":199,"links":919},[920,921,922,923,924,925],{"id":762,"depth":199,"text":763},{"id":801,"depth":199,"text":802},{"id":839,"depth":199,"text":840},{"id":860,"depth":199,"text":861},{"id":891,"depth":199,"text":892},{"id":909,"depth":199,"text":910},"Waarom de hoofdschakelaar in België verplicht is en welke eisen het AREI Art. 5.3.5.1b stelt.","nl",{},"\u002Fblog\u002Fmain-switch-mandatory.nl",{"title":748,"description":926},"hoofdschakelaar-verplicht-arei","blog\u002Fmain-switch-mandatory.nl",[934,222,935,936,225],"hoofdschakelaar","verplicht","verdeler","bt0tci_NgYCLx9cqqLnkyETVtAx9j-gL2dC3l0-2EhA",1775151657876]