[{"data":1,"prerenderedAt":3199},["ShallowReactive",2],{"blog-post-de-renovierung-arei-elektroplaene":3,"blog-alternates-renovation-electrical-plans":712},{"id":4,"title":5,"articleId":6,"body":7,"category":685,"date":686,"description":687,"extension":688,"lastUpdated":689,"locale":690,"meta":691,"navigation":565,"path":692,"publishDate":686,"readTime":693,"refreshInterval":694,"seo":695,"slug":696,"stem":697,"tags":698,"__hash__":711},"blog\u002Fblog\u002Frenovation-electrical-plans.de.md","Renovierung und AREI: Wann brauchen Sie neue Elektropläne?","renovation-electrical-plans",{"type":8,"value":9,"toc":659},"minimark",[10,15,24,28,33,36,125,129,132,195,208,212,215,222,226,229,258,262,284,288,291,347,351,354,378,382,386,389,409,413,420,440,448,452,508,512,515,547,551,554,592,595,622,626,653],[11,12,14],"h2",{"id":13},"wann-löst-eine-renovierung-eine-pflicht-neuabnahme-aus","Wann löst eine Renovierung eine Pflicht-Neuabnahme aus?",[16,17,18,19,23],"p",{},"Nicht jede Renovierung erfordert neue Elektropläne und eine erneute Abnahme. Das AREI unterscheidet klar zwischen Arbeiten, die eine ",[20,21,22],"strong",{},"Neuabnahme"," (keuring) auslösen, und solchen, die das nicht tun. In diesem Leitfaden erfahren Sie, welche Regel für Ihre Renovierung gilt.",[11,25,27],{"id":26},"der-entscheidungsbaum-neuabnahme-ja-oder-nein","Der Entscheidungsbaum: Neuabnahme ja oder nein?",[29,30,32],"h3",{"id":31},"neuabnahme-erforderlich","Neuabnahme ERFORDERLICH",[16,34,35],{},"Folgende Arbeiten lösen eine Pflicht zur erneuten Abnahme aus (Art. 6.4.7.3):",[37,38,39,52],"table",{},[40,41,42],"thead",{},[43,44,45,49],"tr",{},[46,47,48],"th",{},"Arbeit",[46,50,51],{},"Grund",[53,54,55,66,76,85,95,105,115],"tbody",{},[43,56,57,63],{},[58,59,60],"td",{},[20,61,62],{},"Neue Stromkreise hinzufügen",[58,64,65],{},"Erweiterung der Installation",[43,67,68,73],{},[58,69,70],{},[20,71,72],{},"Schaltschrank (Verteiler) austauschen",[58,74,75],{},"Veränderung der Schutzeinrichtungen",[43,77,78,83],{},[58,79,80],{},[20,81,82],{},"Neue Unterverteilung installieren",[58,84,65],{},[43,86,87,92],{},[58,88,89],{},[20,90,91],{},"Kabel neu verlegen",[58,93,94],{},"Wesentliche Änderung",[43,96,97,102],{},[58,98,99],{},[20,100,101],{},"Erdungsanlage verändern",[58,103,104],{},"Sicherheitskritisch",[43,106,107,112],{},[58,108,109],{},[20,110,111],{},"Installation auf Dreiphasig umstellen",[58,113,114],{},"Grundlegende Änderung",[43,116,117,122],{},[58,118,119],{},[20,120,121],{},"Wallbox \u002F Wärmepumpe anschließen",[58,123,124],{},"Neuer dedizierter Stromkreis",[29,126,128],{"id":127},"neuabnahme-nicht-erforderlich","Neuabnahme NICHT ERFORDERLICH",[16,130,131],{},"Diese Arbeiten gelten als Wartung und lösen keine Neuabnahme aus:",[37,133,134,143],{},[40,135,136],{},[43,137,138,140],{},[46,139,48],{},[46,141,142],{},"Warum keine Neuabnahme",[53,144,145,155,165,175,185],{},[43,146,147,152],{},[58,148,149],{},[20,150,151],{},"Steckdose\u002FSchalter 1:1 austauschen",[58,153,154],{},"Gleiche Position, gleiche Leistung",[43,156,157,162],{},[58,158,159],{},[20,160,161],{},"Lampe durch LED ersetzen",[58,163,164],{},"Kein Eingriff in die Installation",[43,166,167,172],{},[58,168,169],{},[20,170,171],{},"Tapezieren, streichen, Böden verlegen",[58,173,174],{},"Kosmetisch, kein Elektroanschluss",[43,176,177,182],{},[58,178,179],{},[20,180,181],{},"Sicherungsautomat 1:1 tauschen",[58,183,184],{},"Gleicher Typ und Nennstrom",[43,186,187,192],{},[58,188,189],{},[20,190,191],{},"Steckdosenabdeckung wechseln",[58,193,194],{},"Kein Eingriff in die Verdrahtung",[196,197,198],"blockquote",{},[16,199,200,203,204,207],{},[20,201,202],{},"Grauzone",": Eine Steckdose an eine ",[20,205,206],{},"andere Position versetzen"," zählt bereits als Änderung. Jede wesentliche Änderung oder Erweiterung löst eine Neuabnahme aus (Art. 6.4.7.3) — auch wenn der Stromkreis gleich bleibt.",[11,209,211],{"id":210},"die-kontaminationsregel","Die Kontaminationsregel",[16,213,214],{},"Die Kontaminationsregel ist das wichtigste Konzept bei Renovierungen:",[196,216,217],{},[16,218,219],{},[20,220,221],{},"Wenn Sie einen Teil der Installation verändern, kann der Inspekteur die gesamte Installation beanstanden.",[29,223,225],{"id":224},"was-das-in-der-praxis-bedeutet","Was das in der Praxis bedeutet",[16,227,228],{},"Angenommen, Sie renovieren Ihr Badezimmer und installieren dort neue Steckdosen und Beleuchtung:",[230,231,232,244,251],"ol",{},[233,234,235,236,239,240,243],"li",{},"Das ",[20,237,238],{},"Badezimmer"," wird nach dem ",[20,241,242],{},"aktuellen AREI"," bewertet — alle aktuellen Vorschriften gelten",[233,245,246,247,250],{},"Der Inspekteur kann auch die ",[20,248,249],{},"restliche Installation"," prüfen",[233,252,253,254,257],{},"Bestehende Mängel (z.B. fehlende FI-Schalter im Keller) können ",[20,255,256],{},"ebenfalls beanstandet"," werden",[29,259,261],{"id":260},"wie-sie-die-kontamination-begrenzen","Wie Sie die Kontamination begrenzen",[263,264,265,271,277],"ul",{},[233,266,267,270],{},[20,268,269],{},"Dokumentieren Sie genau",", welche Teile verändert wurden und welche nicht",[233,272,273,274],{},"Markieren Sie im Eindrahtschema die ",[20,275,276],{},"neuen\u002Fgeänderten Stromkreise",[233,278,279,280,283],{},"Die unveränderten Teile fallen unter ",[20,281,282],{},"Part 8"," (gelockerte Anforderungen)",[11,285,287],{"id":286},"part-8-vs-volles-arei-was-gilt-wann","Part 8 vs. Volles AREI: Was gilt wann?",[16,289,290],{},"Das AREI unterscheidet zwischen Alt und Neu:",[37,292,293,306],{},[40,294,295],{},[43,296,297,300,303],{},[46,298,299],{},"Installationsteil",[46,301,302],{},"Geltende Vorschrift",[46,304,305],{},"Anforderungen",[53,307,308,321,334],{},[43,309,310,315,318],{},[58,311,312],{},[20,313,314],{},"Unverändert, vor 1981",[58,316,317],{},"Part 8 Art. 8.2 (Altinstallation)",[58,319,320],{},"Gelockert — z.B. kein FI pro Kreis nötig, alte Kabeltypen toleriert",[43,322,323,328,331],{},[58,324,325],{},[20,326,327],{},"Unverändert, 1981–2020",[58,329,330],{},"Part 8 Abschnitt 8.2.2 (Abweichungen für hauswirtschaftliche Anlagen nach früherer A.O.E.A.)",[58,332,333],{},"Muss der damaligen Vorschrift entsprechen, mit begrenzten Erleichterungen nach Art. 8.2.2",[43,335,336,341,344],{},[58,337,338],{},[20,339,340],{},"Verändert \u002F Neu",[58,342,343],{},"Aktuelles AREI",[58,345,346],{},"Alle aktuellen Vorschriften (300 mA Haupt-RCD + 30 mA FI hoher Empfindlichkeit für Steckdosen-, Beleuchtungs- und Badezimmer-Stromkreise, SPD für den neuen\u002Fveränderten Teil, Kabelstandards)",[29,348,350],{"id":349},"typisches-szenario-haus-aus-den-1960ern","Typisches Szenario: Haus aus den 1960ern",[16,352,353],{},"Sie renovieren die Küche und das Badezimmer eines Hauses aus 1965:",[263,355,356,362,368],{},[233,357,358,361],{},[20,359,360],{},"Küche + Bad"," (neue Stromkreise): Volles aktuelles AREI — SPD nach den Regeln des Fachs erwartet (Art. 4.5.1, allgemeiner Grundsatz; gilt nur für den neuen\u002Fveränderten Teil der Installation), 300 mA Haupt-RCD für die gesamte Installation (Art. 4.2.4.3) + 30 mA FI hoher Empfindlichkeit für Steckdosen-, Beleuchtungs- und Badezimmer-Stromkreise (Art. 4.2.4.3 Buchstabe b), aktuelle Kabeltypen",[233,363,364,367],{},[20,365,366],{},"Schlafzimmer, Wohnzimmer"," (unverändert): Part 8 — alte VOB-Leitungen toleriert, kein FI pro Kreis nötig",[233,369,370,373,374,377],{},[20,371,372],{},"Aber",": Falls der Inspekteur feststellt, dass die alte Installation ein ",[20,375,376],{},"direktes Sicherheitsrisiko"," darstellt (z.B. blanke Drähte, fehlende Erdung), kann er trotzdem eine Nachbesserung fordern",[11,379,381],{"id":380},"dokumentation-bei-renovierung","Dokumentation bei Renovierung",[29,383,385],{"id":384},"häuser-mit-vorhandenen-plänen","Häuser mit vorhandenen Plänen",[16,387,388],{},"Wenn ein aktuelles Eindrahtschema und Situationsplan existieren:",[230,390,391,397,403],{},[233,392,393,396],{},[20,394,395],{},"Pläne aktualisieren"," — neue Stromkreise, veränderte Positionen eintragen",[233,398,399,402],{},[20,400,401],{},"Kenntlich machen",", was alt und was neu ist",[233,404,405,408],{},[20,406,407],{},"Aktualisierte Pläne"," dem Kontrolleur vorlegen",[29,410,412],{"id":411},"häuser-ohne-pläne-vor-1981","Häuser ohne Pläne (vor 1981)",[16,414,415,416,419],{},"Viele ältere Häuser haben ",[20,417,418],{},"keine vorhandene Dokumentation",". In diesem Fall (Art. 9.1.2):",[230,421,422,428,434],{},[233,423,424,427],{},[20,425,426],{},"Gesamte Installation aufnehmen"," — auch die unveränderten Teile",[233,429,430,433],{},[20,431,432],{},"Eindrahtschema komplett neu erstellen"," — für die gesamte Installation",[233,435,436,439],{},[20,437,438],{},"Situationsplan erstellen"," — alle Steckdosen, Schalter, Leuchten einzeichnen",[196,441,442],{},[16,443,444,447],{},[20,445,446],{},"Achtung",": Dies ist einer der häufigsten Gründe, warum Renovierungen deutlich teurer werden als geplant — die Dokumentationspflicht für die Gesamtinstallation.",[11,449,451],{"id":450},"budgetplanung-typische-kosten","Budgetplanung: Typische Kosten",[37,453,454,464],{},[40,455,456],{},[43,457,458,461],{},[46,459,460],{},"Posten",[46,462,463],{},"Kosten",[53,465,466,474,484,492,500],{},[43,467,468,471],{},[58,469,470],{},"Eindrahtschema + Situationsplan (Elektriker)",[58,472,473],{},"€300 – €600",[43,475,476,479],{},[58,477,478],{},"Eindrahtschema + Situationsplan (PlanElec)",[58,480,481],{},[20,482,483],{},"Early Access derzeit kostenlos",[43,485,486,489],{},[58,487,488],{},"AREI-Abnahme (Keuring)",[58,490,491],{},"€125 – €170",[43,493,494,497],{},[58,495,496],{},"Nachkontrolle (bei Mängeln)",[58,498,499],{},"€80 – €120",[43,501,502,505],{},[58,503,504],{},"Mängelbeseitigung",[58,506,507],{},"€500 – €5.000+",[29,509,511],{"id":510},"der-planelec-vorteil-bei-renovierungen","Der PlanElec-Vorteil bei Renovierungen",[16,513,514],{},"Mit PlanElec können Sie:",[263,516,517,524,530,536,542],{},[233,518,519,520,523],{},"Die ",[20,521,522],{},"bestehende Installation"," aufnehmen und dokumentieren",[233,525,526,529],{},[20,527,528],{},"Neue Stromkreise"," hinzufügen und automatisch validieren lassen",[233,531,532,535],{},[20,533,534],{},"Alt vs. Neu"," klar trennen",[233,537,235,538,541],{},[20,539,540],{},"Ergebnis als PDF"," für den Kontrolleur exportieren",[233,543,544,546],{},[20,545,483],{},"; noch keine Zahlungsabwicklung aktiv",[11,548,550],{"id":549},"checkliste-für-renovierer","Checkliste für Renovierer",[16,552,553],{},"Vor Beginn der Renovierung:",[263,555,558,568,574,580,586],{"className":556},[557],"contains-task-list",[233,559,562,567],{"className":560},[561],"task-list-item",[563,564],"input",{"disabled":565,"type":566},true,"checkbox"," Prüfen: Lösen meine Arbeiten eine Neuabnahme aus?",[233,569,571,573],{"className":570},[561],[563,572],{"disabled":565,"type":566}," Bestehende Elektropläne suchen (falls vorhanden)",[233,575,577,579],{"className":576},[561],[563,578],{"disabled":565,"type":566}," Budget für Dokumentation + Keuring einplanen",[233,581,583,585],{"className":582},[561],[563,584],{"disabled":565,"type":566}," Elektriker frühzeitig einbinden (für die Installation)",[233,587,589,591],{"className":588},[561],[563,590],{"disabled":565,"type":566}," PlanElec für die Dokumentation nutzen (Pläne selbst erstellen)",[16,593,594],{},"Nach der Renovierung:",[263,596,598,604,610,616],{"className":597},[557],[233,599,601,603],{"className":600},[561],[563,602],{"disabled":565,"type":566}," Aktualisierte Pläne erstellt?",[233,605,607,609],{"className":606},[561],[563,608],{"disabled":565,"type":566}," Alle neuen Stromkreise im Eindrahtschema?",[233,611,613,615],{"className":612},[561],[563,614],{"disabled":565,"type":566}," Kontrollorganismus kontaktiert?",[233,617,619,621],{"className":618},[561],[563,620],{"disabled":565,"type":566}," Keuring bestanden?",[11,623,625],{"id":624},"verwandte-artikel","Verwandte Artikel",[263,627,628,635,641,647],{},[233,629,630],{},[631,632,634],"a",{"href":633},"\u002Fde\u002Fblog\u002Faltbau-arei-part-8","Altbau-Elektrik in Belgien: AREI Part 8 erklärt",[233,636,637],{},[631,638,640],{"href":639},"\u002Fde\u002Fblog\u002Felektroplan-kosten","Was kostet ein Elektroplan? Preisvergleich 2026",[233,642,643],{},[631,644,646],{"href":645},"\u002Fde\u002Fblog\u002Fwas-prueft-kontrolleur-stromabnahme","Was prüft der Kontrolleur bei der Stromabnahme?",[233,648,649],{},[631,650,652],{"href":651},"\u002Fde\u002Fblog\u002Felektrodossier-immobilienverkauf","Elektrodossier beim Immobilienverkauf",[16,654,655],{},[631,656,658],{"href":657},"\u002F","Planen Sie Ihre Renovierung AREI-konform mit PlanElec →",{"title":660,"searchDepth":661,"depth":661,"links":662},"",2,[663,664,669,673,676,680,683,684],{"id":13,"depth":661,"text":14},{"id":26,"depth":661,"text":27,"children":665},[666,668],{"id":31,"depth":667,"text":32},3,{"id":127,"depth":667,"text":128},{"id":210,"depth":661,"text":211,"children":670},[671,672],{"id":224,"depth":667,"text":225},{"id":260,"depth":667,"text":261},{"id":286,"depth":661,"text":287,"children":674},[675],{"id":349,"depth":667,"text":350},{"id":380,"depth":661,"text":381,"children":677},[678,679],{"id":384,"depth":667,"text":385},{"id":411,"depth":667,"text":412},{"id":450,"depth":661,"text":451,"children":681},[682],{"id":510,"depth":667,"text":511},{"id":549,"depth":661,"text":550},{"id":624,"depth":661,"text":625},"guide","2026-07-20","Nicht jede Renovierung erfordert neue Elektropläne. Erfahren Sie, welche Arbeiten eine Neuabnahme auslösen und was die Kontaminationsregel bedeutet.","md","2026-06-05","de",{},"\u002Fblog\u002Frenovation-electrical-plans.de","8 min",12,{"title":5,"description":687},"renovierung-arei-elektroplaene","blog\u002Frenovation-electrical-plans.de",[699,700,701,702,703,22,704,282,705,706,707,708,709,710],"AREI","RGIE","Renovierung","Umbau","Elektropläne","Kontaminationsregel","Altinstallation","Eindrahtschema","Situationsplan","Belgien","Stromabnahme","Keuring","rQY4OtPRMM_xqLDXR_ycAXOA-F1xxQ5O1EQeejOWz6Y",[713,1199,1866,2533],{"id":4,"title":5,"articleId":6,"body":714,"category":685,"date":686,"description":687,"extension":688,"lastUpdated":689,"locale":690,"meta":1196,"navigation":565,"path":692,"publishDate":686,"readTime":693,"refreshInterval":694,"seo":1197,"slug":696,"stem":697,"tags":1198,"__hash__":711},{"type":8,"value":715,"toc":1173},[716,718,722,724,726,728,796,798,800,852,860,862,864,870,872,874,890,892,906,908,910,954,956,958,974,976,978,980,994,996,1000,1014,1020,1022,1066,1068,1070,1092,1094,1096,1124,1126,1149,1151,1169],[11,717,14],{"id":13},[16,719,18,720,23],{},[20,721,22],{},[11,723,27],{"id":26},[29,725,32],{"id":31},[16,727,35],{},[37,729,730,738],{},[40,731,732],{},[43,733,734,736],{},[46,735,48],{},[46,737,51],{},[53,739,740,748,756,764,772,780,788],{},[43,741,742,746],{},[58,743,744],{},[20,745,62],{},[58,747,65],{},[43,749,750,754],{},[58,751,752],{},[20,753,72],{},[58,755,75],{},[43,757,758,762],{},[58,759,760],{},[20,761,82],{},[58,763,65],{},[43,765,766,770],{},[58,767,768],{},[20,769,91],{},[58,771,94],{},[43,773,774,778],{},[58,775,776],{},[20,777,101],{},[58,779,104],{},[43,781,782,786],{},[58,783,784],{},[20,785,111],{},[58,787,114],{},[43,789,790,794],{},[58,791,792],{},[20,793,121],{},[58,795,124],{},[29,797,128],{"id":127},[16,799,131],{},[37,801,802,810],{},[40,803,804],{},[43,805,806,808],{},[46,807,48],{},[46,809,142],{},[53,811,812,820,828,836,844],{},[43,813,814,818],{},[58,815,816],{},[20,817,151],{},[58,819,154],{},[43,821,822,826],{},[58,823,824],{},[20,825,161],{},[58,827,164],{},[43,829,830,834],{},[58,831,832],{},[20,833,171],{},[58,835,174],{},[43,837,838,842],{},[58,839,840],{},[20,841,181],{},[58,843,184],{},[43,845,846,850],{},[58,847,848],{},[20,849,191],{},[58,851,194],{},[196,853,854],{},[16,855,856,203,858,207],{},[20,857,202],{},[20,859,206],{},[11,861,211],{"id":210},[16,863,214],{},[196,865,866],{},[16,867,868],{},[20,869,221],{},[29,871,225],{"id":224},[16,873,228],{},[230,875,876,882,886],{},[233,877,235,878,239,880,243],{},[20,879,238],{},[20,881,242],{},[233,883,246,884,250],{},[20,885,249],{},[233,887,253,888,257],{},[20,889,256],{},[29,891,261],{"id":260},[263,893,894,898,902],{},[233,895,896,270],{},[20,897,269],{},[233,899,273,900],{},[20,901,276],{},[233,903,279,904,283],{},[20,905,282],{},[11,907,287],{"id":286},[16,909,290],{},[37,911,912,922],{},[40,913,914],{},[43,915,916,918,920],{},[46,917,299],{},[46,919,302],{},[46,921,305],{},[53,923,924,934,944],{},[43,925,926,930,932],{},[58,927,928],{},[20,929,314],{},[58,931,317],{},[58,933,320],{},[43,935,936,940,942],{},[58,937,938],{},[20,939,327],{},[58,941,330],{},[58,943,333],{},[43,945,946,950,952],{},[58,947,948],{},[20,949,340],{},[58,951,343],{},[58,953,346],{},[29,955,350],{"id":349},[16,957,353],{},[263,959,960,964,968],{},[233,961,962,361],{},[20,963,360],{},[233,965,966,367],{},[20,967,366],{},[233,969,970,373,972,377],{},[20,971,372],{},[20,973,376],{},[11,975,381],{"id":380},[29,977,385],{"id":384},[16,979,388],{},[230,981,982,986,990],{},[233,983,984,396],{},[20,985,395],{},[233,987,988,402],{},[20,989,401],{},[233,991,992,408],{},[20,993,407],{},[29,995,412],{"id":411},[16,997,415,998,419],{},[20,999,418],{},[230,1001,1002,1006,1010],{},[233,1003,1004,427],{},[20,1005,426],{},[233,1007,1008,433],{},[20,1009,432],{},[233,1011,1012,439],{},[20,1013,438],{},[196,1015,1016],{},[16,1017,1018,447],{},[20,1019,446],{},[11,1021,451],{"id":450},[37,1023,1024,1032],{},[40,1025,1026],{},[43,1027,1028,1030],{},[46,1029,460],{},[46,1031,463],{},[53,1033,1034,1040,1048,1054,1060],{},[43,1035,1036,1038],{},[58,1037,470],{},[58,1039,473],{},[43,1041,1042,1044],{},[58,1043,478],{},[58,1045,1046],{},[20,1047,483],{},[43,1049,1050,1052],{},[58,1051,488],{},[58,1053,491],{},[43,1055,1056,1058],{},[58,1057,496],{},[58,1059,499],{},[43,1061,1062,1064],{},[58,1063,504],{},[58,1065,507],{},[29,1067,511],{"id":510},[16,1069,514],{},[263,1071,1072,1076,1080,1084,1088],{},[233,1073,519,1074,523],{},[20,1075,522],{},[233,1077,1078,529],{},[20,1079,528],{},[233,1081,1082,535],{},[20,1083,534],{},[233,1085,235,1086,541],{},[20,1087,540],{},[233,1089,1090,546],{},[20,1091,483],{},[11,1093,550],{"id":549},[16,1095,553],{},[263,1097,1099,1104,1109,1114,1119],{"className":1098},[557],[233,1100,1102,567],{"className":1101},[561],[563,1103],{"disabled":565,"type":566},[233,1105,1107,573],{"className":1106},[561],[563,1108],{"disabled":565,"type":566},[233,1110,1112,579],{"className":1111},[561],[563,1113],{"disabled":565,"type":566},[233,1115,1117,585],{"className":1116},[561],[563,1118],{"disabled":565,"type":566},[233,1120,1122,591],{"className":1121},[561],[563,1123],{"disabled":565,"type":566},[16,1125,594],{},[263,1127,1129,1134,1139,1144],{"className":1128},[557],[233,1130,1132,603],{"className":1131},[561],[563,1133],{"disabled":565,"type":566},[233,1135,1137,609],{"className":1136},[561],[563,1138],{"disabled":565,"type":566},[233,1140,1142,615],{"className":1141},[561],[563,1143],{"disabled":565,"type":566},[233,1145,1147,621],{"className":1146},[561],[563,1148],{"disabled":565,"type":566},[11,1150,625],{"id":624},[263,1152,1153,1157,1161,1165],{},[233,1154,1155],{},[631,1156,634],{"href":633},[233,1158,1159],{},[631,1160,640],{"href":639},[233,1162,1163],{},[631,1164,646],{"href":645},[233,1166,1167],{},[631,1168,652],{"href":651},[16,1170,1171],{},[631,1172,658],{"href":657},{"title":660,"searchDepth":661,"depth":661,"links":1174},[1175,1176,1180,1184,1187,1191,1194,1195],{"id":13,"depth":661,"text":14},{"id":26,"depth":661,"text":27,"children":1177},[1178,1179],{"id":31,"depth":667,"text":32},{"id":127,"depth":667,"text":128},{"id":210,"depth":661,"text":211,"children":1181},[1182,1183],{"id":224,"depth":667,"text":225},{"id":260,"depth":667,"text":261},{"id":286,"depth":661,"text":287,"children":1185},[1186],{"id":349,"depth":667,"text":350},{"id":380,"depth":661,"text":381,"children":1188},[1189,1190],{"id":384,"depth":667,"text":385},{"id":411,"depth":667,"text":412},{"id":450,"depth":661,"text":451,"children":1192},[1193],{"id":510,"depth":667,"text":511},{"id":549,"depth":661,"text":550},{"id":624,"depth":661,"text":625},{},{"title":5,"description":687},[699,700,701,702,703,22,704,282,705,706,707,708,709,710],{"id":1200,"title":1201,"articleId":6,"body":1202,"category":685,"date":686,"description":1848,"extension":688,"lastUpdated":689,"locale":1849,"meta":1850,"navigation":565,"path":1851,"publishDate":686,"readTime":693,"refreshInterval":694,"seo":1852,"slug":6,"stem":1853,"tags":1854,"__hash__":1865},"blog\u002Fblog\u002Frenovation-electrical-plans.en.md","Renovation and AREI: When Do You Need New Electrical Plans?",{"type":8,"value":1203,"toc":1825},[1204,1208,1215,1219,1223,1226,1309,1313,1316,1379,1391,1395,1398,1405,1409,1412,1437,1441,1462,1466,1469,1525,1529,1532,1556,1560,1564,1567,1587,1591,1598,1618,1626,1630,1683,1687,1690,1720,1724,1727,1760,1763,1790,1794,1820],[11,1205,1207],{"id":1206},"when-does-a-renovation-trigger-a-mandatory-re-inspection","When does a renovation trigger a mandatory re-inspection?",[16,1209,1210,1211,1214],{},"Not every renovation requires new electrical plans and a re-inspection. The AREI clearly distinguishes between works that trigger a ",[20,1212,1213],{},"mandatory re-inspection"," (keuring) and those that don't. This guide explains which rule applies to your renovation.",[11,1216,1218],{"id":1217},"the-decision-tree-re-inspection-yes-or-no","The decision tree: Re-inspection yes or no?",[29,1220,1222],{"id":1221},"re-inspection-required","Re-inspection REQUIRED",[16,1224,1225],{},"The following works trigger a mandatory re-inspection (Art. 6.4.7.3):",[37,1227,1228,1238],{},[40,1229,1230],{},[43,1231,1232,1235],{},[46,1233,1234],{},"Work",[46,1236,1237],{},"Reason",[53,1239,1240,1250,1260,1269,1279,1289,1299],{},[43,1241,1242,1247],{},[58,1243,1244],{},[20,1245,1246],{},"Adding new circuits",[58,1248,1249],{},"Extension of the installation",[43,1251,1252,1257],{},[58,1253,1254],{},[20,1255,1256],{},"Replacing the distribution board",[58,1258,1259],{},"Change to protection devices",[43,1261,1262,1267],{},[58,1263,1264],{},[20,1265,1266],{},"Installing a sub-distribution",[58,1268,1249],{},[43,1270,1271,1276],{},[58,1272,1273],{},[20,1274,1275],{},"Running new cables",[58,1277,1278],{},"Substantial modification",[43,1280,1281,1286],{},[58,1282,1283],{},[20,1284,1285],{},"Modifying the earthing system",[58,1287,1288],{},"Safety-critical",[43,1290,1291,1296],{},[58,1292,1293],{},[20,1294,1295],{},"Converting to three-phase",[58,1297,1298],{},"Fundamental change",[43,1300,1301,1306],{},[58,1302,1303],{},[20,1304,1305],{},"Connecting an EV charger \u002F heat pump",[58,1307,1308],{},"New dedicated circuit",[29,1310,1312],{"id":1311},"re-inspection-not-required","Re-inspection NOT REQUIRED",[16,1314,1315],{},"These works count as maintenance and don't trigger a re-inspection:",[37,1317,1318,1327],{},[40,1319,1320],{},[43,1321,1322,1324],{},[46,1323,1234],{},[46,1325,1326],{},"Why no re-inspection",[53,1328,1329,1339,1349,1359,1369],{},[43,1330,1331,1336],{},[58,1332,1333],{},[20,1334,1335],{},"Like-for-like socket\u002Fswitch replacement",[58,1337,1338],{},"Same position, same rating",[43,1340,1341,1346],{},[58,1342,1343],{},[20,1344,1345],{},"Replacing a lamp with LED",[58,1347,1348],{},"No intervention in the installation",[43,1350,1351,1356],{},[58,1352,1353],{},[20,1354,1355],{},"Painting, wallpapering, flooring",[58,1357,1358],{},"Cosmetic, no electrical connection",[43,1360,1361,1366],{},[58,1362,1363],{},[20,1364,1365],{},"Like-for-like breaker replacement",[58,1367,1368],{},"Same type and rated current",[43,1370,1371,1376],{},[58,1372,1373],{},[20,1374,1375],{},"Changing a socket cover plate",[58,1377,1378],{},"No intervention in wiring",[196,1380,1381],{},[16,1382,1383,1386,1387,1390],{},[20,1384,1385],{},"Grey area",": Moving a socket to a ",[20,1388,1389],{},"different position"," already counts as a modification. Any significant modification or extension triggers a re-inspection (Art. 6.4.7.3) — even if the circuit stays the same.",[11,1392,1394],{"id":1393},"the-contamination-rule","The contamination rule",[16,1396,1397],{},"The contamination rule is the most important concept for renovations:",[196,1399,1400],{},[16,1401,1402],{},[20,1403,1404],{},"If you modify one part of the installation, the inspector can question the entire installation.",[29,1406,1408],{"id":1407},"what-this-means-in-practice","What this means in practice",[16,1410,1411],{},"Say you renovate your bathroom and install new sockets and lighting:",[230,1413,1414,1425,1431],{},[233,1415,1416,1417,1420,1421,1424],{},"The ",[20,1418,1419],{},"bathroom"," is assessed against the ",[20,1422,1423],{},"current AREI"," — all current regulations apply",[233,1426,1427,1428],{},"The inspector can also check the ",[20,1429,1430],{},"rest of the installation",[233,1432,1433,1434],{},"Existing defects (e.g., missing RCDs in the basement) can ",[20,1435,1436],{},"also be flagged",[29,1438,1440],{"id":1439},"how-to-limit-contamination","How to limit contamination",[263,1442,1443,1449,1456],{},[233,1444,1445,1448],{},[20,1446,1447],{},"Document precisely"," which parts were modified and which weren't",[233,1450,1451,1452,1455],{},"Mark the ",[20,1453,1454],{},"new\u002Fmodified circuits"," in the single-line diagram",[233,1457,1458,1459,1461],{},"Unmodified parts fall under ",[20,1460,282],{}," (relaxed requirements)",[11,1463,1465],{"id":1464},"part-8-vs-full-arei-what-applies-when","Part 8 vs. Full AREI: What applies when?",[16,1467,1468],{},"The AREI distinguishes between old and new:",[37,1470,1471,1484],{},[40,1472,1473],{},[43,1474,1475,1478,1481],{},[46,1476,1477],{},"Installation part",[46,1479,1480],{},"Applicable regulation",[46,1482,1483],{},"Requirements",[53,1485,1486,1499,1512],{},[43,1487,1488,1493,1496],{},[58,1489,1490],{},[20,1491,1492],{},"Unmodified, pre-1981",[58,1494,1495],{},"Part 8 Art. 8.2 (existing installation)",[58,1497,1498],{},"Relaxed — e.g., no RCD per circuit required, old cable types tolerated",[43,1500,1501,1506,1509],{},[58,1502,1503],{},[20,1504,1505],{},"Unmodified, 1981–2020",[58,1507,1508],{},"Part 8 Section 8.2.2 (deviations for domestic installations under former A.O.E.A.)",[58,1510,1511],{},"Must comply with the regulation at the time, with limited relaxations per Art. 8.2.2",[43,1513,1514,1519,1522],{},[58,1515,1516],{},[20,1517,1518],{},"Modified \u002F New",[58,1520,1521],{},"Current AREI",[58,1523,1524],{},"All current requirements (300 mA main RCD + 30 mA high-sensitivity RCD for socket, lighting and bathroom circuits, SPD for the new\u002Fmodified part, cable standards)",[29,1526,1528],{"id":1527},"typical-scenario-1960s-house","Typical scenario: 1960s house",[16,1530,1531],{},"You're renovating the kitchen and bathroom of a 1965 house:",[263,1533,1534,1540,1546],{},[233,1535,1536,1539],{},[20,1537,1538],{},"Kitchen + bathroom"," (new circuits): Full current AREI — SPD expected as good practice (Art. 4.5.1, general principle; applies only to the new\u002Fmodified part of the installation), 300 mA main RCD for the entire installation (Art. 4.2.4.3) + 30 mA high-sensitivity RCD for socket, lighting and bathroom circuits (Art. 4.2.4.3 point b), current cable types",[233,1541,1542,1545],{},[20,1543,1544],{},"Bedrooms, living room"," (unmodified): Part 8 — old VOB cables tolerated, no RCD per circuit required",[233,1547,1548,1551,1552,1555],{},[20,1549,1550],{},"However",": If the inspector finds that the old installation poses a ",[20,1553,1554],{},"direct safety risk"," (e.g., exposed wires, missing earthing), they can still require remediation",[11,1557,1559],{"id":1558},"documentation-for-renovations","Documentation for renovations",[29,1561,1563],{"id":1562},"houses-with-existing-plans","Houses with existing plans",[16,1565,1566],{},"If a current single-line diagram and situation plan exist:",[230,1568,1569,1575,1581],{},[233,1570,1571,1574],{},[20,1572,1573],{},"Update the plans"," — add new circuits, modified positions",[233,1576,1577,1580],{},[20,1578,1579],{},"Mark clearly"," what is old and what is new",[233,1582,1583,1586],{},[20,1584,1585],{},"Present updated plans"," to the inspector",[29,1588,1590],{"id":1589},"houses-without-plans-pre-1981","Houses without plans (pre-1981)",[16,1592,1593,1594,1597],{},"Many older houses have ",[20,1595,1596],{},"no existing documentation",". In that case (Art. 9.1.2):",[230,1599,1600,1606,1612],{},[233,1601,1602,1605],{},[20,1603,1604],{},"Survey the entire installation"," — including unmodified parts",[233,1607,1608,1611],{},[20,1609,1610],{},"Create a complete new single-line diagram"," — for the entire installation",[233,1613,1614,1617],{},[20,1615,1616],{},"Create a situation plan"," — draw all sockets, switches, lighting points",[196,1619,1620],{},[16,1621,1622,1625],{},[20,1623,1624],{},"Warning",": This is one of the most common reasons renovations become significantly more expensive than planned — the documentation requirement for the entire installation.",[11,1627,1629],{"id":1628},"budget-planning-typical-costs","Budget planning: Typical costs",[37,1631,1632,1642],{},[40,1633,1634],{},[43,1635,1636,1639],{},[46,1637,1638],{},"Item",[46,1640,1641],{},"Cost",[53,1643,1644,1651,1661,1668,1675],{},[43,1645,1646,1649],{},[58,1647,1648],{},"Single-line diagram + situation plan (electrician)",[58,1650,473],{},[43,1652,1653,1656],{},[58,1654,1655],{},"Single-line diagram + situation plan (PlanElec)",[58,1657,1658],{},[20,1659,1660],{},"Early Access currently free",[43,1662,1663,1666],{},[58,1664,1665],{},"AREI inspection",[58,1667,491],{},[43,1669,1670,1673],{},[58,1671,1672],{},"Re-inspection (if defects found)",[58,1674,499],{},[43,1676,1677,1680],{},[58,1678,1679],{},"Defect remediation",[58,1681,1682],{},"€500 – €5,000+",[29,1684,1686],{"id":1685},"the-planelec-advantage-for-renovations","The PlanElec advantage for renovations",[16,1688,1689],{},"With PlanElec, you can:",[263,1691,1692,1697,1703,1709,1715],{},[233,1693,1694],{},[20,1695,1696],{},"Document the existing installation",[233,1698,1699,1702],{},[20,1700,1701],{},"Add new circuits"," and have them automatically validated",[233,1704,1705,1708],{},[20,1706,1707],{},"Clearly separate"," old vs. new",[233,1710,1711,1714],{},[20,1712,1713],{},"Export the result as PDF"," for the inspector",[233,1716,1717,1719],{},[20,1718,1660],{},"; payment processing is not active yet",[11,1721,1723],{"id":1722},"checklist-for-renovators","Checklist for renovators",[16,1725,1726],{},"Before starting renovations:",[263,1728,1730,1736,1742,1748,1754],{"className":1729},[557],[233,1731,1733,1735],{"className":1732},[561],[563,1734],{"disabled":565,"type":566}," Check: Do my works trigger a re-inspection?",[233,1737,1739,1741],{"className":1738},[561],[563,1740],{"disabled":565,"type":566}," Find existing electrical plans (if available)",[233,1743,1745,1747],{"className":1744},[561],[563,1746],{"disabled":565,"type":566}," Budget for documentation + inspection",[233,1749,1751,1753],{"className":1750},[561],[563,1752],{"disabled":565,"type":566}," Involve an electrician early (for the installation work)",[233,1755,1757,1759],{"className":1756},[561],[563,1758],{"disabled":565,"type":566}," Use PlanElec for documentation (create plans yourself)",[16,1761,1762],{},"After renovation:",[263,1764,1766,1772,1778,1784],{"className":1765},[557],[233,1767,1769,1771],{"className":1768},[561],[563,1770],{"disabled":565,"type":566}," Updated plans created?",[233,1773,1775,1777],{"className":1774},[561],[563,1776],{"disabled":565,"type":566}," All new circuits in the single-line diagram?",[233,1779,1781,1783],{"className":1780},[561],[563,1782],{"disabled":565,"type":566}," Inspection body contacted?",[233,1785,1787,1789],{"className":1786},[561],[563,1788],{"disabled":565,"type":566}," Inspection passed?",[11,1791,1793],{"id":1792},"related-articles","Related articles",[263,1795,1796,1802,1808,1814],{},[233,1797,1798],{},[631,1799,1801],{"href":1800},"\u002Fen\u002Fblog\u002Fold-arei-part-8","Old wiring in Belgium: AREI Part 8 explained",[233,1803,1804],{},[631,1805,1807],{"href":1806},"\u002Fen\u002Fblog\u002Felectrical-plan-costs","What does an electrical plan cost? Price comparison 2026",[233,1809,1810],{},[631,1811,1813],{"href":1812},"\u002Fen\u002Fblog\u002Fwhat-inspector-checks","What does the inspector check during the inspection?",[233,1815,1816],{},[631,1817,1819],{"href":1818},"\u002Fen\u002Fblog\u002Fproperty-sale-electrical-dossier","Electrical dossier for property sales",[16,1821,1822],{},[631,1823,1824],{"href":657},"Plan your renovation AREI-compliant with PlanElec →",{"title":660,"searchDepth":661,"depth":661,"links":1826},[1827,1828,1832,1836,1839,1843,1846,1847],{"id":1206,"depth":661,"text":1207},{"id":1217,"depth":661,"text":1218,"children":1829},[1830,1831],{"id":1221,"depth":667,"text":1222},{"id":1311,"depth":667,"text":1312},{"id":1393,"depth":661,"text":1394,"children":1833},[1834,1835],{"id":1407,"depth":667,"text":1408},{"id":1439,"depth":667,"text":1440},{"id":1464,"depth":661,"text":1465,"children":1837},[1838],{"id":1527,"depth":667,"text":1528},{"id":1558,"depth":661,"text":1559,"children":1840},[1841,1842],{"id":1562,"depth":667,"text":1563},{"id":1589,"depth":667,"text":1590},{"id":1628,"depth":661,"text":1629,"children":1844},[1845],{"id":1685,"depth":667,"text":1686},{"id":1722,"depth":661,"text":1723},{"id":1792,"depth":661,"text":1793},"Not every renovation requires new electrical plans. Learn which works trigger a mandatory re-inspection and what the contamination rule means.","en",{},"\u002Fblog\u002Frenovation-electrical-plans.en",{"title":1201,"description":1848},"blog\u002Frenovation-electrical-plans.en",[699,700,1855,1856,1857,1858,1859,282,1860,1861,1862,1863,1864],"renovation","remodelling","electrical plans","re-inspection","contamination rule","existing installation","single-line diagram","situation plan","Belgium","electrical inspection","nCBGxWou4A1hu0rIfPE3lKYrQm_ACfHrrNGlrlCNWII",{"id":1867,"title":1868,"articleId":6,"body":1869,"category":685,"date":686,"description":2515,"extension":688,"lastUpdated":689,"locale":2516,"meta":2517,"navigation":565,"path":2518,"publishDate":686,"readTime":693,"refreshInterval":694,"seo":2519,"slug":2520,"stem":2521,"tags":2522,"__hash__":2532},"blog\u002Fblog\u002Frenovation-electrical-plans.fr.md","Rénovation et RGIE : Quand avez-vous besoin de nouveaux plans électriques ?",{"type":8,"value":1870,"toc":2492},[1871,1875,1882,1886,1890,1893,1976,1980,1983,2046,2058,2062,2065,2072,2076,2079,2104,2108,2128,2132,2135,2190,2194,2197,2221,2225,2229,2232,2252,2256,2263,2283,2291,2295,2351,2355,2358,2387,2391,2394,2427,2430,2457,2461,2487],[11,1872,1874],{"id":1873},"quand-une-rénovation-déclenche-t-elle-un-contrôle-obligatoire","Quand une rénovation déclenche-t-elle un contrôle obligatoire ?",[16,1876,1877,1878,1881],{},"Toute rénovation ne nécessite pas de nouveaux plans électriques et un nouveau contrôle. Le RGIE distingue clairement les travaux qui déclenchent un ",[20,1879,1880],{},"nouveau contrôle"," de ceux qui ne le font pas. Ce guide vous explique quelle règle s'applique à votre rénovation.",[11,1883,1885],{"id":1884},"larbre-de-décision-nouveau-contrôle-oui-ou-non","L'arbre de décision : Nouveau contrôle oui ou non ?",[29,1887,1889],{"id":1888},"nouveau-contrôle-requis","Nouveau contrôle REQUIS",[16,1891,1892],{},"Les travaux suivants déclenchent un contrôle obligatoire (Art. 6.4.7.3) :",[37,1894,1895,1905],{},[40,1896,1897],{},[43,1898,1899,1902],{},[46,1900,1901],{},"Travaux",[46,1903,1904],{},"Raison",[53,1906,1907,1917,1927,1936,1946,1956,1966],{},[43,1908,1909,1914],{},[58,1910,1911],{},[20,1912,1913],{},"Ajouter de nouveaux circuits",[58,1915,1916],{},"Extension de l'installation",[43,1918,1919,1924],{},[58,1920,1921],{},[20,1922,1923],{},"Remplacer le tableau de distribution",[58,1925,1926],{},"Modification des dispositifs de protection",[43,1928,1929,1934],{},[58,1930,1931],{},[20,1932,1933],{},"Installer un sous-tableau",[58,1935,1916],{},[43,1937,1938,1943],{},[58,1939,1940],{},[20,1941,1942],{},"Poser de nouveaux câbles",[58,1944,1945],{},"Modification substantielle",[43,1947,1948,1953],{},[58,1949,1950],{},[20,1951,1952],{},"Modifier l'installation de mise à la terre",[58,1954,1955],{},"Critique pour la sécurité",[43,1957,1958,1963],{},[58,1959,1960],{},[20,1961,1962],{},"Passer en triphasé",[58,1964,1965],{},"Modification fondamentale",[43,1967,1968,1973],{},[58,1969,1970],{},[20,1971,1972],{},"Raccorder une borne de recharge \u002F pompe à chaleur",[58,1974,1975],{},"Nouveau circuit dédié",[29,1977,1979],{"id":1978},"nouveau-contrôle-non-requis","Nouveau contrôle NON REQUIS",[16,1981,1982],{},"Ces travaux sont considérés comme de la maintenance :",[37,1984,1985,1994],{},[40,1986,1987],{},[43,1988,1989,1991],{},[46,1990,1901],{},[46,1992,1993],{},"Pourquoi pas de nouveau contrôle",[53,1995,1996,2006,2016,2026,2036],{},[43,1997,1998,2003],{},[58,1999,2000],{},[20,2001,2002],{},"Remplacement 1-pour-1 d'une prise\u002Finterrupteur",[58,2004,2005],{},"Même position, même puissance",[43,2007,2008,2013],{},[58,2009,2010],{},[20,2011,2012],{},"Remplacer une lampe par une LED",[58,2014,2015],{},"Pas d'intervention sur l'installation",[43,2017,2018,2023],{},[58,2019,2020],{},[20,2021,2022],{},"Peindre, tapisser, poser des sols",[58,2024,2025],{},"Cosmétique, pas de raccordement électrique",[43,2027,2028,2033],{},[58,2029,2030],{},[20,2031,2032],{},"Remplacement 1-pour-1 d'un disjoncteur",[58,2034,2035],{},"Même type et courant nominal",[43,2037,2038,2043],{},[58,2039,2040],{},[20,2041,2042],{},"Changer un couvercle de prise",[58,2044,2045],{},"Pas d'intervention sur le câblage",[196,2047,2048],{},[16,2049,2050,2053,2054,2057],{},[20,2051,2052],{},"Zone grise"," : Déplacer une prise vers une ",[20,2055,2056],{},"autre position"," constitue déjà une modification. Toute modification ou extension significative déclenche un nouveau contrôle (Art. 6.4.7.3) — même si le circuit reste le même.",[11,2059,2061],{"id":2060},"la-règle-de-contamination","La règle de contamination",[16,2063,2064],{},"La règle de contamination est le concept le plus important lors des rénovations :",[196,2066,2067],{},[16,2068,2069],{},[20,2070,2071],{},"Si vous modifiez une partie de l'installation, le contrôleur peut remettre en question l'ensemble de l'installation.",[29,2073,2075],{"id":2074},"ce-que-cela-signifie-en-pratique","Ce que cela signifie en pratique",[16,2077,2078],{},"Supposons que vous rénovez votre salle de bain et y installez de nouvelles prises et un nouvel éclairage :",[230,2080,2081,2092,2098],{},[233,2082,2083,2084,2087,2088,2091],{},"La ",[20,2085,2086],{},"salle de bain"," est évaluée selon le ",[20,2089,2090],{},"RGIE actuel"," — toutes les prescriptions actuelles s'appliquent",[233,2093,2094,2095],{},"Le contrôleur peut également vérifier le ",[20,2096,2097],{},"reste de l'installation",[233,2099,2100,2101],{},"Les défauts existants (p. ex. différentiels manquants à la cave) peuvent ",[20,2102,2103],{},"également être signalés",[29,2105,2107],{"id":2106},"comment-limiter-la-contamination","Comment limiter la contamination",[263,2109,2110,2116,2122],{},[233,2111,2112,2115],{},[20,2113,2114],{},"Documentez précisément"," quelles parties ont été modifiées et lesquelles ne l'ont pas été",[233,2117,2118,2119],{},"Marquez dans le schéma unifilaire les ",[20,2120,2121],{},"circuits nouveaux\u002Fmodifiés",[233,2123,2124,2125,2127],{},"Les parties inchangées relèvent du ",[20,2126,282],{}," (exigences assouplies)",[11,2129,2131],{"id":2130},"part-8-vs-rgie-complet-que-sapplique-quand","Part 8 vs. RGIE complet : Que s'applique quand ?",[16,2133,2134],{},"Le RGIE distingue entre ancien et nouveau :",[37,2136,2137,2150],{},[40,2138,2139],{},[43,2140,2141,2144,2147],{},[46,2142,2143],{},"Partie de l'installation",[46,2145,2146],{},"Prescription applicable",[46,2148,2149],{},"Exigences",[53,2151,2152,2165,2178],{},[43,2153,2154,2159,2162],{},[58,2155,2156],{},[20,2157,2158],{},"Inchangée, avant 1981",[58,2160,2161],{},"Part 8 Art. 8.2 (installation existante)",[58,2163,2164],{},"Assouplies — p. ex. pas de différentiel par circuit requis, anciens types de câbles tolérés",[43,2166,2167,2172,2175],{},[58,2168,2169],{},[20,2170,2171],{},"Inchangée, 1981–2020",[58,2173,2174],{},"Part 8 Section 8.2.2 (dérogations pour installations domestiques selon l'ancien R.G.I.E.)",[58,2176,2177],{},"Doit correspondre à la prescription de l'époque, avec des allègements limités selon Art. 8.2.2",[43,2179,2180,2185,2187],{},[58,2181,2182],{},[20,2183,2184],{},"Modifiée \u002F Nouvelle",[58,2186,2090],{},[58,2188,2189],{},"Toutes les prescriptions actuelles (différentiel principal 300 mA + différentiel 30 mA à haute sensibilité pour les circuits prises, éclairage et salle de bain, SPD pour la partie nouvelle\u002Fmodifiée, normes de câbles)",[29,2191,2193],{"id":2192},"scénario-typique-maison-des-années-1960","Scénario typique : Maison des années 1960",[16,2195,2196],{},"Vous rénovez la cuisine et la salle de bain d'une maison de 1965 :",[263,2198,2199,2205,2211],{},[233,2200,2201,2204],{},[20,2202,2203],{},"Cuisine + salle de bain"," (nouveaux circuits) : RGIE actuel complet — SPD attendu selon les règles de l'art (Art. 4.5.1, principe général ; uniquement pour la partie nouvelle\u002Fmodifiée de l'installation), différentiel principal 300 mA pour l'ensemble de l'installation (Art. 4.2.4.3) + différentiel 30 mA à haute sensibilité pour les circuits prises, éclairage et salle de bain (Art. 4.2.4.3 point b), types de câbles actuels",[233,2206,2207,2210],{},[20,2208,2209],{},"Chambres, salon"," (inchangés) : Part 8 — anciens câbles VOB tolérés, pas de différentiel par circuit requis",[233,2212,2213,2216,2217,2220],{},[20,2214,2215],{},"Mais"," : Si le contrôleur constate que l'ancienne installation présente un ",[20,2218,2219],{},"risque de sécurité direct"," (p. ex. fils dénudés, mise à la terre manquante), il peut quand même exiger une mise en conformité",[11,2222,2224],{"id":2223},"documentation-lors-dune-rénovation","Documentation lors d'une rénovation",[29,2226,2228],{"id":2227},"maisons-avec-plans-existants","Maisons avec plans existants",[16,2230,2231],{},"Si un schéma unifilaire et un plan de situation actuels existent :",[230,2233,2234,2240,2246],{},[233,2235,2236,2239],{},[20,2237,2238],{},"Mettre à jour les plans"," — ajouter les nouveaux circuits, positions modifiées",[233,2241,2242,2245],{},[20,2243,2244],{},"Marquer"," ce qui est ancien et ce qui est nouveau",[233,2247,2248,2251],{},[20,2249,2250],{},"Présenter les plans mis à jour"," au contrôleur",[29,2253,2255],{"id":2254},"maisons-sans-plans-avant-1981","Maisons sans plans (avant 1981)",[16,2257,2258,2259,2262],{},"De nombreuses maisons anciennes n'ont ",[20,2260,2261],{},"pas de documentation existante",". Dans ce cas (Art. 9.1.2) :",[230,2264,2265,2271,2277],{},[233,2266,2267,2270],{},[20,2268,2269],{},"Relever l'installation complète"," — y compris les parties inchangées",[233,2272,2273,2276],{},[20,2274,2275],{},"Créer un nouveau schéma unifilaire complet"," — pour toute l'installation",[233,2278,2279,2282],{},[20,2280,2281],{},"Établir un plan de situation"," — dessiner toutes les prises, interrupteurs, points lumineux",[196,2284,2285],{},[16,2286,2287,2290],{},[20,2288,2289],{},"Attention"," : C'est l'une des raisons les plus fréquentes pour lesquelles les rénovations coûtent nettement plus cher que prévu — l'obligation de documentation pour l'ensemble de l'installation.",[11,2292,2294],{"id":2293},"budget-coûts-typiques","Budget : Coûts typiques",[37,2296,2297,2307],{},[40,2298,2299],{},[43,2300,2301,2304],{},[46,2302,2303],{},"Poste",[46,2305,2306],{},"Coût",[53,2308,2309,2317,2327,2335,2343],{},[43,2310,2311,2314],{},[58,2312,2313],{},"Schéma unifilaire + plan de situation (électricien)",[58,2315,2316],{},"300 € – 600 €",[43,2318,2319,2322],{},[58,2320,2321],{},"Schéma unifilaire + plan de situation (PlanElec)",[58,2323,2324],{},[20,2325,2326],{},"Early Access actuellement gratuit",[43,2328,2329,2332],{},[58,2330,2331],{},"Contrôle RGIE",[58,2333,2334],{},"125 € – 170 €",[43,2336,2337,2340],{},[58,2338,2339],{},"Recontrôle (en cas de défauts)",[58,2341,2342],{},"80 € – 120 €",[43,2344,2345,2348],{},[58,2346,2347],{},"Correction des défauts",[58,2349,2350],{},"500 € – 5 000 €+",[29,2352,2354],{"id":2353},"lavantage-planelec-pour-les-rénovations","L'avantage PlanElec pour les rénovations",[16,2356,2357],{},"Avec PlanElec, vous pouvez :",[263,2359,2360,2365,2370,2376,2382],{},[233,2361,2362],{},[20,2363,2364],{},"Documenter l'installation existante",[233,2366,2367,2369],{},[20,2368,1913],{}," et les faire valider automatiquement",[233,2371,2372,2375],{},[20,2373,2374],{},"Séparer clairement"," ancien et nouveau",[233,2377,2378,2381],{},[20,2379,2380],{},"Exporter le résultat en PDF"," pour le contrôleur",[233,2383,2384,2386],{},[20,2385,2326],{}," ; aucun paiement n'est encore activé",[11,2388,2390],{"id":2389},"checklist-pour-les-rénovateurs","Checklist pour les rénovateurs",[16,2392,2393],{},"Avant le début des travaux :",[263,2395,2397,2403,2409,2415,2421],{"className":2396},[557],[233,2398,2400,2402],{"className":2399},[561],[563,2401],{"disabled":565,"type":566}," Vérifier : Mes travaux déclenchent-ils un nouveau contrôle ?",[233,2404,2406,2408],{"className":2405},[561],[563,2407],{"disabled":565,"type":566}," Rechercher les plans électriques existants (si disponibles)",[233,2410,2412,2414],{"className":2411},[561],[563,2413],{"disabled":565,"type":566}," Prévoir un budget pour la documentation + le contrôle",[233,2416,2418,2420],{"className":2417},[561],[563,2419],{"disabled":565,"type":566}," Impliquer un électricien à temps (pour l'installation)",[233,2422,2424,2426],{"className":2423},[561],[563,2425],{"disabled":565,"type":566}," Utiliser PlanElec pour la documentation (créer les plans soi-même)",[16,2428,2429],{},"Après la rénovation :",[263,2431,2433,2439,2445,2451],{"className":2432},[557],[233,2434,2436,2438],{"className":2435},[561],[563,2437],{"disabled":565,"type":566}," Plans mis à jour créés ?",[233,2440,2442,2444],{"className":2441},[561],[563,2443],{"disabled":565,"type":566}," Tous les nouveaux circuits dans le schéma unifilaire ?",[233,2446,2448,2450],{"className":2447},[561],[563,2449],{"disabled":565,"type":566}," Organisme de contrôle contacté ?",[233,2452,2454,2456],{"className":2453},[561],[563,2455],{"disabled":565,"type":566}," Contrôle réussi ?",[11,2458,2460],{"id":2459},"articles-connexes","Articles connexes",[263,2462,2463,2469,2475,2481],{},[233,2464,2465],{},[631,2466,2468],{"href":2467},"\u002Ffr\u002Fblog\u002Fancien-rgie-part-8","L'électricité dans les bâtiments anciens en Belgique : Part 8 du RGIE expliqué",[233,2470,2471],{},[631,2472,2474],{"href":2473},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique ? Comparatif de prix 2026",[233,2476,2477],{},[631,2478,2480],{"href":2479},"\u002Ffr\u002Fblog\u002Fque-verifie-controleur-inspection","Que vérifie le contrôleur lors de l'inspection ?",[233,2482,2483],{},[631,2484,2486],{"href":2485},"\u002Ffr\u002Fblog\u002Fdossier-electrique-vente-immobiliere","Dossier électrique lors de la vente immobilière",[16,2488,2489],{},[631,2490,2491],{"href":657},"Planifiez votre rénovation conformément au RGIE avec PlanElec →",{"title":660,"searchDepth":661,"depth":661,"links":2493},[2494,2495,2499,2503,2506,2510,2513,2514],{"id":1873,"depth":661,"text":1874},{"id":1884,"depth":661,"text":1885,"children":2496},[2497,2498],{"id":1888,"depth":667,"text":1889},{"id":1978,"depth":667,"text":1979},{"id":2060,"depth":661,"text":2061,"children":2500},[2501,2502],{"id":2074,"depth":667,"text":2075},{"id":2106,"depth":667,"text":2107},{"id":2130,"depth":661,"text":2131,"children":2504},[2505],{"id":2192,"depth":667,"text":2193},{"id":2223,"depth":661,"text":2224,"children":2507},[2508,2509],{"id":2227,"depth":667,"text":2228},{"id":2254,"depth":667,"text":2255},{"id":2293,"depth":661,"text":2294,"children":2511},[2512],{"id":2353,"depth":667,"text":2354},{"id":2389,"depth":661,"text":2390},{"id":2459,"depth":661,"text":2460},"Toute rénovation ne nécessite pas de nouveaux plans électriques. Découvrez quels travaux déclenchent un nouveau contrôle et ce que signifie la règle de contamination.","fr",{},"\u002Fblog\u002Frenovation-electrical-plans.fr",{"title":1868,"description":2515},"renovation-rgie-plans-electriques","blog\u002Frenovation-electrical-plans.fr",[699,700,2523,2524,2525,1880,2526,282,2527,2528,2529,2530,2531],"rénovation","travaux","plans électriques","règle de contamination","installation existante","schéma unifilaire","plan de situation","Belgique","contrôle électrique","pskrogmRqJWTAe8uqagWBkG-SWIRTPB01k5T573VlFo",{"id":2534,"title":2535,"articleId":6,"body":2536,"category":685,"date":686,"description":3182,"extension":688,"lastUpdated":689,"locale":3183,"meta":3184,"navigation":565,"path":3185,"publishDate":686,"readTime":693,"refreshInterval":694,"seo":3186,"slug":3187,"stem":3188,"tags":3189,"__hash__":3198},"blog\u002Fblog\u002Frenovation-electrical-plans.nl.md","Renovatie en AREI: Wanneer hebt u nieuwe elektrische plannen nodig?",{"type":8,"value":2537,"toc":3159},[2538,2542,2549,2553,2557,2560,2643,2647,2650,2713,2725,2729,2732,2739,2743,2746,2772,2776,2796,2800,2803,2859,2863,2866,2890,2894,2898,2901,2921,2925,2932,2952,2960,2964,3015,3019,3022,3054,3058,3061,3094,3097,3124,3128,3154],[11,2539,2541],{"id":2540},"wanneer-vereist-een-renovatie-een-verplichte-herkeuring","Wanneer vereist een renovatie een verplichte herkeuring?",[16,2543,2544,2545,2548],{},"Niet elke renovatie vereist nieuwe elektrische plannen en een herkeuring. Het AREI maakt een duidelijk onderscheid tussen werken die een ",[20,2546,2547],{},"herkeuring"," uitlokken en werken waarvoor dat niet geldt. In deze gids leest u welke regel voor uw renovatie van toepassing is.",[11,2550,2552],{"id":2551},"de-beslissingsboom-herkeuring-ja-of-nee","De beslissingsboom: Herkeuring ja of nee?",[29,2554,2556],{"id":2555},"herkeuring-vereist","Herkeuring VEREIST",[16,2558,2559],{},"Volgende werken vereisen een verplichte herkeuring (Art. 6.4.7.3):",[37,2561,2562,2572],{},[40,2563,2564],{},[43,2565,2566,2569],{},[46,2567,2568],{},"Werk",[46,2570,2571],{},"Reden",[53,2573,2574,2584,2594,2603,2613,2623,2633],{},[43,2575,2576,2581],{},[58,2577,2578],{},[20,2579,2580],{},"Nieuwe stroomkringen toevoegen",[58,2582,2583],{},"Uitbreiding van de installatie",[43,2585,2586,2591],{},[58,2587,2588],{},[20,2589,2590],{},"Verdeelkast vervangen",[58,2592,2593],{},"Wijziging van de beveiligingstoestellen",[43,2595,2596,2601],{},[58,2597,2598],{},[20,2599,2600],{},"Nieuwe onderverdeling installeren",[58,2602,2583],{},[43,2604,2605,2610],{},[58,2606,2607],{},[20,2608,2609],{},"Kabels opnieuw trekken",[58,2611,2612],{},"Wezenlijke wijziging",[43,2614,2615,2620],{},[58,2616,2617],{},[20,2618,2619],{},"Aardingsinstallatie wijzigen",[58,2621,2622],{},"Veiligheidskritisch",[43,2624,2625,2630],{},[58,2626,2627],{},[20,2628,2629],{},"Overschakelen naar driefasig",[58,2631,2632],{},"Fundamentele wijziging",[43,2634,2635,2640],{},[58,2636,2637],{},[20,2638,2639],{},"Laadpaal \u002F warmtepomp aansluiten",[58,2641,2642],{},"Nieuwe eigen stroomkring",[29,2644,2646],{"id":2645},"herkeuring-niet-vereist","Herkeuring NIET VEREIST",[16,2648,2649],{},"Deze werken gelden als onderhoud en lokken geen herkeuring uit:",[37,2651,2652,2661],{},[40,2653,2654],{},[43,2655,2656,2658],{},[46,2657,2568],{},[46,2659,2660],{},"Waarom geen herkeuring",[53,2662,2663,2673,2683,2693,2703],{},[43,2664,2665,2670],{},[58,2666,2667],{},[20,2668,2669],{},"Stopcontact\u002Fschakelaar 1-op-1 vervangen",[58,2671,2672],{},"Zelfde positie, zelfde vermogen",[43,2674,2675,2680],{},[58,2676,2677],{},[20,2678,2679],{},"Lamp door LED vervangen",[58,2681,2682],{},"Geen ingreep in de installatie",[43,2684,2685,2690],{},[58,2686,2687],{},[20,2688,2689],{},"Behangen, schilderen, vloeren leggen",[58,2691,2692],{},"Cosmetisch, geen elektrische aanpassing",[43,2694,2695,2700],{},[58,2696,2697],{},[20,2698,2699],{},"Automaat 1-op-1 vervangen",[58,2701,2702],{},"Zelfde type en nominale stroom",[43,2704,2705,2710],{},[58,2706,2707],{},[20,2708,2709],{},"Afdekplaatje stopcontact wisselen",[58,2711,2712],{},"Geen ingreep in de bedrading",[196,2714,2715],{},[16,2716,2717,2720,2721,2724],{},[20,2718,2719],{},"Grijze zone",": Een stopcontact naar een ",[20,2722,2723],{},"andere positie verplaatsen"," geldt al als wijziging. Elke belangrijke wijziging of uitbreiding lokt een herkeuring uit (Art. 6.4.7.3) — ook als de stroomkring dezelfde blijft.",[11,2726,2728],{"id":2727},"de-contaminatieregel","De contaminatieregel",[16,2730,2731],{},"De contaminatieregel is het belangrijkste concept bij renovaties:",[196,2733,2734],{},[16,2735,2736],{},[20,2737,2738],{},"Als u een deel van de installatie wijzigt, kan de inspecteur de volledige installatie in vraag stellen.",[29,2740,2742],{"id":2741},"wat-dit-in-de-praktijk-betekent","Wat dit in de praktijk betekent",[16,2744,2745],{},"Stel dat u uw badkamer renoveert en daar nieuwe stopcontacten en verlichting installeert:",[230,2747,2748,2759,2766],{},[233,2749,2750,2751,2754,2755,2758],{},"De ",[20,2752,2753],{},"badkamer"," wordt beoordeeld volgens het ",[20,2756,2757],{},"huidige AREI"," — alle actuele voorschriften gelden",[233,2760,2761,2762,2765],{},"De inspecteur kan ook de ",[20,2763,2764],{},"rest van de installatie"," controleren",[233,2767,2768,2769],{},"Bestaande gebreken (bijv. ontbrekende differentieelschakelaars in de kelder) kunnen ",[20,2770,2771],{},"ook worden opgemerkt",[29,2773,2775],{"id":2774},"hoe-u-de-contaminatie-beperkt","Hoe u de contaminatie beperkt",[263,2777,2778,2784,2790],{},[233,2779,2780,2783],{},[20,2781,2782],{},"Documenteer nauwkeurig"," welke delen gewijzigd zijn en welke niet",[233,2785,2786,2787],{},"Markeer in het eendraadschema de ",[20,2788,2789],{},"nieuwe\u002Fgewijzigde stroomkringen",[233,2791,2792,2793,2795],{},"De ongewijzigde delen vallen onder ",[20,2794,282],{}," (soepelere eisen)",[11,2797,2799],{"id":2798},"part-8-vs-volledig-arei-wat-geldt-wanneer","Part 8 vs. Volledig AREI: Wat geldt wanneer?",[16,2801,2802],{},"Het AREI onderscheidt tussen oud en nieuw:",[37,2804,2805,2818],{},[40,2806,2807],{},[43,2808,2809,2812,2815],{},[46,2810,2811],{},"Installatiedeel",[46,2813,2814],{},"Geldend voorschrift",[46,2816,2817],{},"Eisen",[53,2819,2820,2833,2846],{},[43,2821,2822,2827,2830],{},[58,2823,2824],{},[20,2825,2826],{},"Ongewijzigd, vóór 1981",[58,2828,2829],{},"Part 8 Art. 8.2 (bestaande installatie)",[58,2831,2832],{},"Soepeler — bijv. geen differentieel per kring nodig, oude kabeltypes getolereerd",[43,2834,2835,2840,2843],{},[58,2836,2837],{},[20,2838,2839],{},"Ongewijzigd, 1981–2020",[58,2841,2842],{},"Part 8 Art. 8.2.2 (afwijkingen voor huishoudelijke installaties volgens het vroegere A.R.E.I.)",[58,2844,2845],{},"Moet voldoen aan het toenmalige voorschrift, met beperkte versoepelingen conform Art. 8.2.2",[43,2847,2848,2853,2856],{},[58,2849,2850],{},[20,2851,2852],{},"Gewijzigd \u002F Nieuw",[58,2854,2855],{},"Actueel AREI",[58,2857,2858],{},"Alle huidige voorschriften (300 mA hoofd-RCD + 30 mA differentieelschakelaar met hoge gevoeligheid voor stopcontact-, verlichtings- en badkamerkringen, SPD voor het nieuwe\u002Fgewijzigde deel, kabelstandaarden)",[29,2860,2862],{"id":2861},"typisch-scenario-woning-uit-de-jaren-1960","Typisch scenario: Woning uit de jaren 1960",[16,2864,2865],{},"U renoveert de keuken en de badkamer van een woning uit 1965:",[263,2867,2868,2874,2880],{},[233,2869,2870,2873],{},[20,2871,2872],{},"Keuken + badkamer"," (nieuwe kringen): Volledig huidig AREI — SPD verwacht volgens de regels van de kunst (Art. 4.5.1, algemeen principe; geldt alleen voor het nieuwe\u002Fgewijzigde deel van de installatie), 300 mA hoofd-RCD voor de gehele installatie (Art. 4.2.4.3) + 30 mA differentieelschakelaar met hoge gevoeligheid voor stopcontact-, verlichtings- en badkamerkringen (Art. 4.2.4.3 punt b), actuele kabeltypes",[233,2875,2876,2879],{},[20,2877,2878],{},"Slaapkamers, woonkamer"," (ongewijzigd): Part 8 — oude VOB-leidingen getolereerd, geen differentieel per kring nodig",[233,2881,2882,2885,2886,2889],{},[20,2883,2884],{},"Maar",": Als de inspecteur vaststelt dat de oude installatie een ",[20,2887,2888],{},"direct veiligheidsrisico"," vormt (bijv. blote draden, ontbrekende aarding), kan hij toch een aanpassing eisen",[11,2891,2893],{"id":2892},"documentatie-bij-renovatie","Documentatie bij renovatie",[29,2895,2897],{"id":2896},"woningen-met-bestaande-plannen","Woningen met bestaande plannen",[16,2899,2900],{},"Als een actueel eendraadschema en situatieschema bestaan:",[230,2902,2903,2909,2915],{},[233,2904,2905,2908],{},[20,2906,2907],{},"Plannen bijwerken"," — nieuwe kringen, gewijzigde posities invoeren",[233,2910,2911,2914],{},[20,2912,2913],{},"Markeren"," wat oud is en wat nieuw",[233,2916,2917,2920],{},[20,2918,2919],{},"Bijgewerkte plannen"," aan de inspecteur voorleggen",[29,2922,2924],{"id":2923},"woningen-zonder-plannen-vóór-1981","Woningen zonder plannen (vóór 1981)",[16,2926,2927,2928,2931],{},"Veel oudere woningen hebben ",[20,2929,2930],{},"geen bestaande documentatie",". In dat geval (Art. 9.1.2):",[230,2933,2934,2940,2946],{},[233,2935,2936,2939],{},[20,2937,2938],{},"Volledige installatie opmeten"," — ook de ongewijzigde delen",[233,2941,2942,2945],{},[20,2943,2944],{},"Eendraadschema volledig opnieuw opstellen"," — voor de gehele installatie",[233,2947,2948,2951],{},[20,2949,2950],{},"Situatieschema opstellen"," — alle stopcontacten, schakelaars, verlichtingspunten intekenen",[196,2953,2954],{},[16,2955,2956,2959],{},[20,2957,2958],{},"Let op",": Dit is een van de meest voorkomende redenen waarom renovaties aanzienlijk duurder uitvallen dan gepland — de documentatieplicht voor de volledige installatie.",[11,2961,2963],{"id":2962},"budgetplanning-typische-kosten","Budgetplanning: Typische kosten",[37,2965,2966,2975],{},[40,2967,2968],{},[43,2969,2970,2973],{},[46,2971,2972],{},"Post",[46,2974,463],{},[53,2976,2977,2984,2994,3001,3008],{},[43,2978,2979,2982],{},[58,2980,2981],{},"Eendraadschema + situatieschema (elektricien)",[58,2983,473],{},[43,2985,2986,2989],{},[58,2987,2988],{},"Eendraadschema + situatieschema (PlanElec)",[58,2990,2991],{},[20,2992,2993],{},"Early Access momenteel gratis",[43,2995,2996,2999],{},[58,2997,2998],{},"AREI-keuring",[58,3000,491],{},[43,3002,3003,3006],{},[58,3004,3005],{},"Herkeuring (bij gebreken)",[58,3007,499],{},[43,3009,3010,3013],{},[58,3011,3012],{},"Gebrekenverhelping",[58,3014,507],{},[29,3016,3018],{"id":3017},"het-planelec-voordeel-bij-renovaties","Het PlanElec-voordeel bij renovaties",[16,3020,3021],{},"Met PlanElec kunt u:",[263,3023,3024,3030,3036,3042,3049],{},[233,3025,2750,3026,3029],{},[20,3027,3028],{},"bestaande installatie"," opmeten en documenteren",[233,3031,3032,3035],{},[20,3033,3034],{},"Nieuwe stroomkringen"," toevoegen en automatisch laten valideren",[233,3037,3038,3041],{},[20,3039,3040],{},"Oud vs. nieuw"," duidelijk scheiden",[233,3043,3044,3045,3048],{},"Het ",[20,3046,3047],{},"resultaat als PDF"," exporteren voor de inspecteur",[233,3050,3051,3053],{},[20,3052,2993],{},"; betalingsverwerking is nog niet actief",[11,3055,3057],{"id":3056},"checklist-voor-renoveerders","Checklist voor renoveerders",[16,3059,3060],{},"Vóór aanvang van de renovatie:",[263,3062,3064,3070,3076,3082,3088],{"className":3063},[557],[233,3065,3067,3069],{"className":3066},[561],[563,3068],{"disabled":565,"type":566}," Controleren: Lokken mijn werken een herkeuring uit?",[233,3071,3073,3075],{"className":3072},[561],[563,3074],{"disabled":565,"type":566}," Bestaande elektrische plannen opzoeken (indien beschikbaar)",[233,3077,3079,3081],{"className":3078},[561],[563,3080],{"disabled":565,"type":566}," Budget voor documentatie + keuring inplannen",[233,3083,3085,3087],{"className":3084},[561],[563,3086],{"disabled":565,"type":566}," Elektricien tijdig inschakelen (voor de installatie)",[233,3089,3091,3093],{"className":3090},[561],[563,3092],{"disabled":565,"type":566}," PlanElec gebruiken voor de documentatie (plannen zelf opstellen)",[16,3095,3096],{},"Na de renovatie:",[263,3098,3100,3106,3112,3118],{"className":3099},[557],[233,3101,3103,3105],{"className":3102},[561],[563,3104],{"disabled":565,"type":566}," Bijgewerkte plannen opgesteld?",[233,3107,3109,3111],{"className":3108},[561],[563,3110],{"disabled":565,"type":566}," Alle nieuwe stroomkringen in het eendraadschema?",[233,3113,3115,3117],{"className":3114},[561],[563,3116],{"disabled":565,"type":566}," Controleorganisme gecontacteerd?",[233,3119,3121,3123],{"className":3120},[561],[563,3122],{"disabled":565,"type":566}," Keuring geslaagd?",[11,3125,3127],{"id":3126},"gerelateerde-artikelen","Gerelateerde artikelen",[263,3129,3130,3136,3142,3148],{},[233,3131,3132],{},[631,3133,3135],{"href":3134},"\u002Fnl\u002Fblog\u002Foud-arei-part-8","Oude elektriciteit in België: AREI Part 8 uitgelegd",[233,3137,3138],{},[631,3139,3141],{"href":3140},"\u002Fnl\u002Fblog\u002Felektroplan-kosten","Wat kost een elektroplan? Prijsvergelijking 2026",[233,3143,3144],{},[631,3145,3147],{"href":3146},"\u002Fnl\u002Fblog\u002Fwat-controleert-inspecteur-keuring","Wat controleert de inspecteur bij de keuring?",[233,3149,3150],{},[631,3151,3153],{"href":3152},"\u002Fnl\u002Fblog\u002Felektrisch-dossier-woningverkoop","Elektrisch dossier bij woningverkoop",[16,3155,3156],{},[631,3157,3158],{"href":657},"Plan uw renovatie AREI-conform met PlanElec →",{"title":660,"searchDepth":661,"depth":661,"links":3160},[3161,3162,3166,3170,3173,3177,3180,3181],{"id":2540,"depth":661,"text":2541},{"id":2551,"depth":661,"text":2552,"children":3163},[3164,3165],{"id":2555,"depth":667,"text":2556},{"id":2645,"depth":667,"text":2646},{"id":2727,"depth":661,"text":2728,"children":3167},[3168,3169],{"id":2741,"depth":667,"text":2742},{"id":2774,"depth":667,"text":2775},{"id":2798,"depth":661,"text":2799,"children":3171},[3172],{"id":2861,"depth":667,"text":2862},{"id":2892,"depth":661,"text":2893,"children":3174},[3175,3176],{"id":2896,"depth":667,"text":2897},{"id":2923,"depth":667,"text":2924},{"id":2962,"depth":661,"text":2963,"children":3178},[3179],{"id":3017,"depth":667,"text":3018},{"id":3056,"depth":661,"text":3057},{"id":3126,"depth":661,"text":3127},"Niet elke renovatie vereist nieuwe elektrische plannen. Ontdek welke werken een herkeuring uitlokken en wat de contaminatieregel inhoudt.","nl",{},"\u002Fblog\u002Frenovation-electrical-plans.nl",{"title":2535,"description":3182},"renovatie-arei-elektrische-plannen","blog\u002Frenovation-electrical-plans.nl",[699,700,3190,3191,3192,2547,3193,282,3028,3194,3195,3196,3197],"renovatie","verbouwing","elektrische plannen","contaminatieregel","eendraadschema","situatieschema","België","elektrische keuring","V-hTzF5yCRbfz-0ZSsiw2y4hwXjXjkXyAUBy0lD8NDY",1785171270876]