[{"data":1,"prerenderedAt":5934},["ShallowReactive",2],{"blog-post-de-schaltschrank-planen-aufbau":3,"blog-alternates-distribution-board-planning":1300},{"id":4,"title":5,"articleId":6,"body":7,"category":1278,"date":1279,"description":1280,"extension":1281,"lastUpdated":1279,"locale":1282,"meta":1283,"navigation":1284,"path":1285,"publishDate":1279,"readTime":1286,"refreshInterval":1287,"seo":1288,"slug":1289,"stem":1290,"tags":1291,"__hash__":1299},"blog\u002Fblog\u002Fdistribution-board-planning.de.md","Schaltschrank planen: Aufbau und Dimensionierung nach AREI","distribution-board-planning",{"type":8,"value":9,"toc":1249},"minimark",[10,14,18,21,26,31,43,47,58,153,157,160,232,240,242,246,249,396,408,410,414,421,425,436,444,448,516,520,527,529,533,537,544,548,601,603,607,614,628,633,644,646,650,653,657,738,742,853,857,960,964,1064,1069,1071,1075,1169,1171,1175,1182,1193,1200,1202,1206,1233,1235],[11,12,5],"h1",{"id":13},"schaltschrank-planen-aufbau-und-dimensionierung-nach-arei",[15,16,17],"p",{},"Der Verteilerschrank (auch Sicherungskasten, Schaltschrank oder Zählerschrank) ist das Herzstück jeder Elektroinstallation. Hier laufen alle Stromkreise zusammen, hier sitzen die Schutzgeräte, die Ihr Haus und Ihre Familie vor elektrischen Gefahren schützen. Eine durchdachte Planung spart nicht nur Geld, sondern verhindert auch Probleme bei der AREI-Kontrolle.",[19,20],"hr",{},[22,23,25],"h2",{"id":24},"grundlagen-aufbau-eines-verteilerschranks","Grundlagen: Aufbau eines Verteilerschranks",[27,28,30],"h3",{"id":29},"din-schiene-hutschiene","DIN-Schiene (Hutschiene)",[15,32,33,34,38,39,42],{},"Alle Module im Verteiler werden auf standardisierte ",[35,36,37],"strong",{},"DIN-Schienen"," (35 mm Hutschiene nach EN 60715) aufgeschnappt. Jede Schiene bildet eine ",[35,40,41],{},"Reihe"," im Verteiler.",[27,44,46],{"id":45},"te-einheiten-teilungseinheiten","TE-Einheiten (Teilungseinheiten)",[15,48,49,50,53,54,57],{},"Die Breite eines Moduls wird in ",[35,51,52],{},"TE"," (Teilungseinheiten) gemessen. Eine TE entspricht ",[35,55,56],{},"18 mm",". Typische Breiten:",[59,60,61,74],"table",{},[62,63,64],"thead",{},[65,66,67,71],"tr",{},[68,69,70],"th",{},"Modul",[68,72,73],{},"Breite (TE)",[75,76,77,86,94,102,109,117,124,131,139,146],"tbody",{},[65,78,79,83],{},[80,81,82],"td",{},"MCB 1-polig",[80,84,85],{},"1 TE",[65,87,88,91],{},[80,89,90],{},"MCB 2-polig",[80,92,93],{},"2 TE",[65,95,96,99],{},[80,97,98],{},"MCB 3-polig",[80,100,101],{},"3 TE",[65,103,104,107],{},[80,105,106],{},"RCD 2-polig (30 mA \u002F 300 mA)",[80,108,93],{},[65,110,111,114],{},[80,112,113],{},"RCD 4-polig",[80,115,116],{},"4 TE",[65,118,119,122],{},[80,120,121],{},"Hauptschalter 2-polig",[80,123,93],{},[65,125,126,129],{},[80,127,128],{},"Hauptschalter 4-polig",[80,130,116],{},[65,132,133,136],{},[80,134,135],{},"SPD (Überspannungsschutz)",[80,137,138],{},"2–4 TE",[65,140,141,144],{},[80,142,143],{},"Klingeltransformator",[80,145,93],{},[65,147,148,151],{},[80,149,150],{},"Zeitschaltuhr",[80,152,93],{},[27,154,156],{"id":155},"verteilergrößen","Verteilergrößen",[15,158,159],{},"Verteiler werden nach Reihen und TE pro Reihe dimensioniert:",[59,161,162,178],{},[62,163,164],{},[65,165,166,169,172,175],{},[68,167,168],{},"Bezeichnung",[68,170,171],{},"Reihen",[68,173,174],{},"TE pro Reihe",[68,176,177],{},"Gesamt-TE",[75,179,180,193,206,219],{},[65,181,182,185,188,191],{},[80,183,184],{},"1-reihig",[80,186,187],{},"1",[80,189,190],{},"12–18",[80,192,190],{},[65,194,195,198,201,203],{},[80,196,197],{},"2-reihig",[80,199,200],{},"2",[80,202,190],{},[80,204,205],{},"24–36",[65,207,208,211,214,216],{},[80,209,210],{},"3-reihig",[80,212,213],{},"3",[80,215,190],{},[80,217,218],{},"36–54",[65,220,221,224,227,229],{},[80,222,223],{},"4-reihig",[80,225,226],{},"4",[80,228,190],{},[80,230,231],{},"48–72",[233,234,235],"blockquote",{},[15,236,237],{},[35,238,239],{},"Für ein typisches Einfamilienhaus empfehlen wir mindestens einen 4-reihigen Verteiler mit 18 TE pro Reihe (72 TE gesamt).",[19,241],{},[22,243,245],{"id":244},"schritt-1-stromkreise-zählen","Schritt 1: Stromkreise zählen",[15,247,248],{},"Listen Sie alle benötigten Stromkreise auf. Für ein durchschnittliches Einfamilienhaus (3 Schlafzimmer, 150 m²) rechnen Sie mit:",[59,250,251,264],{},[62,252,253],{},[65,254,255,258,261],{},[68,256,257],{},"Typ",[68,259,260],{},"Anzahl",[68,262,263],{},"MCB",[75,265,266,277,288,298,308,317,326,335,344,353,363,372,382],{},[65,267,268,271,274],{},[80,269,270],{},"Beleuchtung",[80,272,273],{},"3–4 Kreise",[80,275,276],{},"B10A oder B16A",[65,278,279,282,285],{},[80,280,281],{},"Steckdosen allgemein",[80,283,284],{},"4–6 Kreise",[80,286,287],{},"B16A",[65,289,290,293,295],{},[80,291,292],{},"Küche dediziert (Backofen)",[80,294,187],{},[80,296,297],{},"B20A mit mind. 2,5 mm², B25A mit 4 mm², B32A mit 6 mm²",[65,299,300,303,305],{},[80,301,302],{},"Küche dediziert (Kochfeld)",[80,304,187],{},[80,306,307],{},"B32A (3-phasig ggf.)",[65,309,310,313,315],{},[80,311,312],{},"Küche dediziert (Geschirrspüler)",[80,314,187],{},[80,316,287],{},[65,318,319,322,324],{},[80,320,321],{},"Waschmaschine",[80,323,187],{},[80,325,287],{},[65,327,328,331,333],{},[80,329,330],{},"Trockner",[80,332,187],{},[80,334,287],{},[65,336,337,340,342],{},[80,338,339],{},"Badezimmer Steckdosen",[80,341,187],{},[80,343,287],{},[65,345,346,349,351],{},[80,347,348],{},"Außensteckdosen",[80,350,187],{},[80,352,287],{},[65,354,355,358,360],{},[80,356,357],{},"Boiler \u002F Warmwasser",[80,359,187],{},[80,361,362],{},"B16A oder B20A",[65,364,365,368,370],{},[80,366,367],{},"Garage",[80,369,187],{},[80,371,287],{},[65,373,374,377,379],{},[80,375,376],{},"Wallbox (falls vorhanden)",[80,378,187],{},[80,380,381],{},"B32A",[65,383,384,389,394],{},[80,385,386],{},[35,387,388],{},"Gesamt",[80,390,391],{},[35,392,393],{},"17–21 Kreise",[80,395],{},[233,397,398],{},[15,399,400,403,404,407],{},[35,401,402],{},"Tipp:"," Maximal ",[35,405,406],{},"8 Steckdosen"," pro Stromkreis (AREI Art. 5.3.5.2b). Lichtkreise dürfen mehr Punkte haben, aber in der Praxis empfehlen sich max. 8 Leuchten pro Kreis.",[19,409],{},[22,411,413],{"id":412},"schritt-2-schutzgeräte-wählen","Schritt 2: Schutzgeräte wählen",[15,415,416,417,420],{},"Die Schutzgeräte werden ",[35,418,419],{},"hierarchisch"," angeordnet — von der Einspeisung (oben) nach unten:",[27,422,424],{"id":423},"hierarchie-der-schutzgeräte","Hierarchie der Schutzgeräte",[426,427,432],"pre",{"className":428,"code":430,"language":431},[429],"language-text","Hauptschalter (40A oder 63A)\n   └── Haupt-RCD 300 mA (Typ A-S, selektiv)\n        ├── Gruppen-RCD 30 mA #1 (Typ A)\n        │    ├── MCB Licht EG (B10A)\n        │    ├── MCB Licht OG (B10A)\n        │    ├── MCB Steckdosen WZ (B16A)\n        │    └── MCB Steckdosen Flur (B16A)\n        ├── Gruppen-RCD 30 mA #2 (Typ A)\n        │    ├── MCB Steckdosen Küche (B16A)\n        │    ├── MCB Backofen (B20A)\n        │    ├── MCB Geschirrspüler (B16A)\n        │    └── MCB Steckdosen SZ (B16A)\n        └── Gruppen-RCD 30 mA #3 (Typ A)\n             ├── MCB Waschmaschine (B16A)\n             ├── MCB Bad (B16A)\n             ├── MCB Außen (B16A)\n             └── MCB Garage (B16A)\n","text",[433,434,430],"code",{"__ignoreMap":435},"",[233,437,438],{},[15,439,440,443],{},[35,441,442],{},"Hinweis:"," Bei dreiphasigem Anschluss (3N~400V) werden 4-polige Hauptschalter, RCDs und ggf. MCBs benötigt.",[27,445,447],{"id":446},"rcd-typen","RCD-Typen",[59,449,450,462],{},[62,451,452],{},[65,453,454,456,459],{},[68,455,257],{},[68,457,458],{},"Auslösestrom",[68,460,461],{},"Einsatz",[75,463,464,477,490,503],{},[65,465,466,471,474],{},[80,467,468],{},[35,469,470],{},"300 mA Typ A-S",[80,472,473],{},"300 mA, selektiv (zeitverzögert)",[80,475,476],{},"Haupt-RCD, löst nur bei Fehler hinter Gruppen-RCDs",[65,478,479,484,487],{},[80,480,481],{},[35,482,483],{},"30 mA Typ A",[80,485,486],{},"30 mA, unverzögert",[80,488,489],{},"Gruppen-RCD, Personenschutz",[65,491,492,497,500],{},[80,493,494],{},[35,495,496],{},"30 mA Typ B",[80,498,499],{},"30 mA, Allstromsensitiv",[80,501,502],{},"Für Wallbox \u002F Wechselrichter mit DC-Komponente",[65,504,505,510,513],{},[80,506,507],{},[35,508,509],{},"30 mA Typ F",[80,511,512],{},"30 mA, frequenzsensitiv (erkennt frequenzgemischte Fehlerströme durch Frequenzumrichter, bis 1 kHz)",[80,514,515],{},"Für Frequenzumrichter (Wärmepumpe)",[27,517,519],{"id":518},"selektivität","Selektivität",[15,521,522,523,526],{},"Der Haupt-RCD (300 mA, ",[35,524,525],{},"Typ S"," = selektiv) ist zeitverzögert und löst erst aus, wenn der Gruppen-RCD (30 mA) nicht reagiert hat. Dadurch fällt bei einem Fehler nur der betroffene Gruppen-RCD, nicht die gesamte Anlage.",[19,528],{},[22,530,532],{"id":531},"schritt-3-aufteilung-auf-reihen","Schritt 3: Aufteilung auf Reihen",[27,534,536],{"id":535},"arei-regel-max-8-endstromkreise-pro-rcd","AREI-Regel: Max. 8 Endstromkreise pro RCD",[15,538,539,540,543],{},"Gemäß AREI Art. 4.2.4.3b dürfen maximal ",[35,541,542],{},"8 Endstromkreise"," hinter einer Differenzstrom-Schutzeinrichtung (RCD) angeschlossen werden. In der Praxis empfehlen sich 4–6 MCBs pro RCD für eine komfortable Reserve.",[27,545,547],{"id":546},"typische-reihenaufteilung","Typische Reihenaufteilung",[59,549,550,559],{},[62,551,552],{},[65,553,554,556],{},[68,555,41],{},[68,557,558],{},"Inhalt",[75,560,561,571,581,591],{},[65,562,563,568],{},[80,564,565],{},[35,566,567],{},"Reihe 1",[80,569,570],{},"Hauptschalter, Haupt-RCD (300 mA), SPD, evtl. Klingeltransformator",[65,572,573,578],{},[80,574,575],{},[35,576,577],{},"Reihe 2",[80,579,580],{},"Gruppen-RCD #1 (30 mA) + zugehörige MCBs (Licht + Steckdosen Wohnen)",[65,582,583,588],{},[80,584,585],{},[35,586,587],{},"Reihe 3",[80,589,590],{},"Gruppen-RCD #2 (30 mA) + zugehörige MCBs (Küche + Schlafzimmer)",[65,592,593,598],{},[80,594,595],{},[35,596,597],{},"Reihe 4",[80,599,600],{},"Gruppen-RCD #3 (30 mA) + zugehörige MCBs (Bad, Außen, Garage, Technik)",[19,602],{},[22,604,606],{"id":605},"schritt-4-reserveplätze-einplanen","Schritt 4: Reserveplätze einplanen",[15,608,609,610,613],{},"Planen Sie mindestens ",[35,611,612],{},"20 % Reserveplätze"," ein — besser 30 %. Das bedeutet:",[615,616,617,621],"ul",{},[618,619,620],"li",{},"Bei 20 benötigten MCBs → mindestens 4–6 freie TE-Plätze.",[618,622,623,624,627],{},"Leere Plätze werden mit ",[35,625,626],{},"Blindabdeckungen"," verschlossen.",[15,629,630],{},[35,631,632],{},"Warum?",[615,634,635,638,641],{},[618,636,637],{},"Zukünftige Erweiterungen (Wallbox, Klimaanlage, Saunaöfen).",[618,639,640],{},"Umverteilung, wenn ein RCD zu viele Kreise hat.",[618,642,643],{},"Vermeidung eines teuren Verteilertauschs.",[19,645],{},[22,647,649],{"id":648},"beispiel-layout-4-reihen-verteiler-für-einfamilienhaus","Beispiel-Layout: 4-Reihen-Verteiler für Einfamilienhaus",[15,651,652],{},"Hier ein komplettes Beispiel für ein typisches belgisches Einfamilienhaus (3 SZ, 150 m², ohne PV):",[27,654,656],{"id":655},"reihe-1-einspeisung-schutz-18-te","Reihe 1 — Einspeisung & Schutz (18 TE)",[59,658,659,673],{},[62,660,661],{},[65,662,663,666,668,670],{},[68,664,665],{},"Position",[68,667,70],{},[68,669,52],{},[68,671,672],{},"Funktion",[75,674,675,688,700,713,725],{},[65,676,677,680,683,685],{},[80,678,679],{},"1–2",[80,681,682],{},"Hauptschalter 2P",[80,684,200],{},[80,686,687],{},"40A Hauptschalter",[65,689,690,693,696,698],{},[80,691,692],{},"3–4",[80,694,695],{},"Haupt-RCD 2P",[80,697,200],{},[80,699,470],{},[65,701,702,705,708,710],{},[80,703,704],{},"5–8",[80,706,707],{},"SPD",[80,709,226],{},[80,711,712],{},"Überspannungsschutz",[65,714,715,718,720,722],{},[80,716,717],{},"9–10",[80,719,143],{},[80,721,200],{},[80,723,724],{},"8V Klingel",[65,726,727,730,733,736],{},[80,728,729],{},"11–18",[80,731,732],{},"Reserve",[80,734,735],{},"8",[80,737,626],{},[27,739,741],{"id":740},"reihe-2-gruppe-1-beleuchtung-wohnen-18-te","Reihe 2 — Gruppe 1: Beleuchtung + Wohnen (18 TE)",[59,743,744,756],{},[62,745,746],{},[65,747,748,750,752,754],{},[68,749,665],{},[68,751,70],{},[68,753,52],{},[68,755,672],{},[75,757,758,770,782,793,805,818,830,841],{},[65,759,760,762,765,767],{},[80,761,679],{},[80,763,764],{},"Gruppen-RCD 30 mA",[80,766,200],{},[80,768,769],{},"Typ A",[65,771,772,774,777,779],{},[80,773,213],{},[80,775,776],{},"MCB B10A",[80,778,187],{},[80,780,781],{},"Licht Erdgeschoss",[65,783,784,786,788,790],{},[80,785,226],{},[80,787,776],{},[80,789,187],{},[80,791,792],{},"Licht Obergeschoss",[65,794,795,798,800,802],{},[80,796,797],{},"5",[80,799,776],{},[80,801,187],{},[80,803,804],{},"Licht Keller\u002FAußen",[65,806,807,810,813,815],{},[80,808,809],{},"6",[80,811,812],{},"MCB B16A",[80,814,187],{},[80,816,817],{},"Steckdosen Wohnzimmer",[65,819,820,823,825,827],{},[80,821,822],{},"7",[80,824,812],{},[80,826,187],{},[80,828,829],{},"Steckdosen Esszimmer",[65,831,832,834,836,838],{},[80,833,735],{},[80,835,812],{},[80,837,187],{},[80,839,840],{},"Steckdosen Flur",[65,842,843,846,848,851],{},[80,844,845],{},"9–18",[80,847,732],{},[80,849,850],{},"10",[80,852,626],{},[27,854,856],{"id":855},"reihe-3-gruppe-2-küche-schlafzimmer-18-te","Reihe 3 — Gruppe 2: Küche + Schlafzimmer (18 TE)",[59,858,859,871],{},[62,860,861],{},[65,862,863,865,867,869],{},[68,864,665],{},[68,866,70],{},[68,868,52],{},[68,870,672],{},[75,872,873,883,894,906,917,928,939,950],{},[65,874,875,877,879,881],{},[80,876,679],{},[80,878,764],{},[80,880,200],{},[80,882,769],{},[65,884,885,887,889,891],{},[80,886,213],{},[80,888,812],{},[80,890,187],{},[80,892,893],{},"Steckdosen Küche",[65,895,896,898,901,903],{},[80,897,226],{},[80,899,900],{},"MCB B20A",[80,902,187],{},[80,904,905],{},"Backofen (dediziert)",[65,907,908,910,912,914],{},[80,909,797],{},[80,911,812],{},[80,913,187],{},[80,915,916],{},"Geschirrspüler (dediziert)",[65,918,919,921,923,925],{},[80,920,809],{},[80,922,812],{},[80,924,187],{},[80,926,927],{},"Kühlschrank (dediziert)",[65,929,930,932,934,936],{},[80,931,822],{},[80,933,812],{},[80,935,187],{},[80,937,938],{},"Steckdosen Schlafzimmer 1",[65,940,941,943,945,947],{},[80,942,735],{},[80,944,812],{},[80,946,187],{},[80,948,949],{},"Steckdosen Schlafzimmer 2+3",[65,951,952,954,956,958],{},[80,953,845],{},[80,955,732],{},[80,957,850],{},[80,959,626],{},[27,961,963],{"id":962},"reihe-4-gruppe-3-bad-außen-technik-18-te","Reihe 4 — Gruppe 3: Bad, Außen, Technik (18 TE)",[59,965,966,978],{},[62,967,968],{},[65,969,970,972,974,976],{},[68,971,665],{},[68,973,70],{},[68,975,52],{},[68,977,672],{},[75,979,980,990,1001,1012,1023,1034,1044,1054],{},[65,981,982,984,986,988],{},[80,983,679],{},[80,985,764],{},[80,987,200],{},[80,989,769],{},[65,991,992,994,996,998],{},[80,993,213],{},[80,995,812],{},[80,997,187],{},[80,999,1000],{},"Steckdosen Badezimmer",[65,1002,1003,1005,1007,1009],{},[80,1004,226],{},[80,1006,812],{},[80,1008,187],{},[80,1010,1011],{},"Waschmaschine (dediziert)",[65,1013,1014,1016,1018,1020],{},[80,1015,797],{},[80,1017,812],{},[80,1019,187],{},[80,1021,1022],{},"Trockner (dediziert)",[65,1024,1025,1027,1029,1031],{},[80,1026,809],{},[80,1028,900],{},[80,1030,187],{},[80,1032,1033],{},"Boiler (dediziert)",[65,1035,1036,1038,1040,1042],{},[80,1037,822],{},[80,1039,812],{},[80,1041,187],{},[80,1043,348],{},[65,1045,1046,1048,1050,1052],{},[80,1047,735],{},[80,1049,812],{},[80,1051,187],{},[80,1053,367],{},[65,1055,1056,1058,1060,1062],{},[80,1057,845],{},[80,1059,732],{},[80,1061,850],{},[80,1063,626],{},[15,1065,1066],{},[35,1067,1068],{},"Gesamt: 24 MCBs + 4 RCDs + SPD + Hauptschalter = ca. 40 TE belegt von 72 TE → 44 % Reserve",[19,1070],{},[22,1072,1074],{"id":1073},"typische-fehler-bei-der-schaltschrankplanung","Typische Fehler bei der Schaltschrankplanung",[59,1076,1077,1090],{},[62,1078,1079],{},[65,1080,1081,1084,1087],{},[68,1082,1083],{},"Fehler",[68,1085,1086],{},"Konsequenz",[68,1088,1089],{},"Lösung",[75,1091,1092,1103,1114,1125,1136,1147,1158],{},[65,1093,1094,1097,1100],{},[80,1095,1096],{},"Zu wenig Reihen",[80,1098,1099],{},"Kein Platz für Erweiterungen",[80,1101,1102],{},"Mind. 4 Reihen für EFH",[65,1104,1105,1108,1111],{},[80,1106,1107],{},"Kein SPD (Überspannungsschutz)",[80,1109,1110],{},"Empfohlen nach Regeln des Fachs (Art. 4.5.1)",[80,1112,1113],{},"SPD vorsehen",[65,1115,1116,1119,1122],{},[80,1117,1118],{},"Mehr als 8 Endstromkreise pro RCD",[80,1120,1121],{},"AREI-Verstoß (Art. 4.2.4.3b)",[80,1123,1124],{},"Zusätzlichen Gruppen-RCD einbauen",[65,1126,1127,1130,1133],{},[80,1128,1129],{},"Fehlende Beschriftung",[80,1131,1132],{},"Beanstandung bei Kontrolle",[80,1134,1135],{},"Jeden MCB beschriften (Kreisnummer + Funktion)",[65,1137,1138,1141,1144],{},[80,1139,1140],{},"Kein Haupt-RCD 300 mA",[80,1142,1143],{},"Fehlende Selektivität",[80,1145,1146],{},"Immer Haupt-RCD vorsehen",[65,1148,1149,1152,1155],{},[80,1150,1151],{},"Falscher RCD-Typ für Wallbox",[80,1153,1154],{},"Fehlerhafte Abschaltung",[80,1156,1157],{},"Typ B oder Typ A-EV verwenden",[65,1159,1160,1163,1166],{},[80,1161,1162],{},"Keine Reserve",[80,1164,1165],{},"Teure Nachrüstung",[80,1167,1168],{},"Mind. 20 % Freiplätze",[19,1170],{},[22,1172,1174],{"id":1173},"beschriftung-und-dokumentation","Beschriftung und Dokumentation",[15,1176,1177,1178,1181],{},"Jeder MCB muss ",[35,1179,1180],{},"beschriftet"," werden mit:",[615,1183,1184,1187,1190],{},[618,1185,1186],{},"Stromkreisnummer (identisch zum Eindrahtschema und Situationsplan)",[618,1188,1189],{},"Funktion (z. B. „Licht EG\", „Steckdosen Küche\")",[618,1191,1192],{},"Optional: Raum oder Etage",[15,1194,1195,1196,1199],{},"Kleben Sie die Beschriftung ",[35,1197,1198],{},"in den Deckel"," des Verteilers oder verwenden Sie einen Beschriftungsstreifen. Die meisten Verteilerhersteller liefern beschreibbare Einleger mit.",[19,1201],{},[22,1203,1205],{"id":1204},"verwandte-artikel","Verwandte Artikel",[615,1207,1208,1215,1221,1227],{},[618,1209,1210],{},[1211,1212,1214],"a",{"href":1213},"\u002Fde\u002Fblog\u002Fwas-ist-eindrahtschema","Was ist ein Eindrahtschema?",[618,1216,1217],{},[1211,1218,1220],{"href":1219},"\u002Fde\u002Fblog\u002F30ma-rcd-pro-steckdose","30-mA-RCD Pflicht pro Steckdosenkreis",[618,1222,1223],{},[1211,1224,1226],{"href":1225},"\u002Fde\u002Fblog\u002Fkabelquerschnitt-sicherungsautomat","Kabelquerschnitt und Sicherungsautomat: Die richtige Kombination",[618,1228,1229],{},[1211,1230,1232],{"href":1231},"\u002Fde\u002Fblog\u002Fpv-anlage-schema","PV-Anlage im Schema",[19,1234],{},[15,1236,1237],{},[1238,1239,1240,1241,1244,1245],"em",{},"Planen Sie Ihren Verteilerschrank visuell mit dem ",[35,1242,1243],{},"PlanElec Cabinet Editor"," — Module per Drag & Drop auf die DIN-Schiene setzen, automatische AREI-Prüfung inklusive. ",[1211,1246,1248],{"href":1247},"\u002F","Jetzt ausprobieren →",{"title":435,"searchDepth":1250,"depth":1250,"links":1251},2,[1252,1258,1259,1264,1268,1269,1275,1276,1277],{"id":24,"depth":1250,"text":25,"children":1253},[1254,1256,1257],{"id":29,"depth":1255,"text":30},3,{"id":45,"depth":1255,"text":46},{"id":155,"depth":1255,"text":156},{"id":244,"depth":1250,"text":245},{"id":412,"depth":1250,"text":413,"children":1260},[1261,1262,1263],{"id":423,"depth":1255,"text":424},{"id":446,"depth":1255,"text":447},{"id":518,"depth":1255,"text":519},{"id":531,"depth":1250,"text":532,"children":1265},[1266,1267],{"id":535,"depth":1255,"text":536},{"id":546,"depth":1255,"text":547},{"id":605,"depth":1250,"text":606},{"id":648,"depth":1250,"text":649,"children":1270},[1271,1272,1273,1274],{"id":655,"depth":1255,"text":656},{"id":740,"depth":1255,"text":741},{"id":855,"depth":1255,"text":856},{"id":962,"depth":1255,"text":963},{"id":1073,"depth":1250,"text":1074},{"id":1173,"depth":1250,"text":1174},{"id":1204,"depth":1250,"text":1205},"guide","2026-04-07","Vollständige Anleitung zur Planung eines Verteilerschranks. DIN-Schiene, Schutzgeräte, Reihenaufteilung und Beispiel-Layout für ein Einfamilienhaus.","md","de",{},true,"\u002Fblog\u002Fdistribution-board-planning.de","8 min",12,{"title":5,"description":1280},"schaltschrank-planen-aufbau","blog\u002Fdistribution-board-planning.de",[1292,1293,1294,1295,263,1296,1297,1298],"schaltschrank","verteiler","DIN-Schiene","RCD","AREI","planung","einfamilienhaus","j1if-qW9_fdElRIbV6zYRuFVA0FRhWYlcbk_Jt9eU8I",[1301,2297,3515,4731],{"id":4,"title":5,"articleId":6,"body":1302,"category":1278,"date":1279,"description":1280,"extension":1281,"lastUpdated":1279,"locale":1282,"meta":2294,"navigation":1284,"path":1285,"publishDate":1279,"readTime":1286,"refreshInterval":1287,"seo":2295,"slug":1289,"stem":1290,"tags":2296,"__hash__":1299},{"type":8,"value":1303,"toc":2267},[1304,1306,1308,1310,1312,1314,1320,1322,1328,1400,1402,1404,1460,1466,1468,1470,1472,1594,1602,1604,1606,1610,1612,1617,1623,1625,1679,1681,1685,1687,1689,1691,1695,1697,1741,1743,1745,1749,1757,1761,1769,1771,1773,1775,1777,1843,1845,1941,1943,2039,2041,2137,2141,2143,2145,2215,2217,2219,2223,2231,2235,2237,2239,2257,2259],[11,1305,5],{"id":13},[15,1307,17],{},[19,1309],{},[22,1311,25],{"id":24},[27,1313,30],{"id":29},[15,1315,33,1316,38,1318,42],{},[35,1317,37],{},[35,1319,41],{},[27,1321,46],{"id":45},[15,1323,49,1324,53,1326,57],{},[35,1325,52],{},[35,1327,56],{},[59,1329,1330,1338],{},[62,1331,1332],{},[65,1333,1334,1336],{},[68,1335,70],{},[68,1337,73],{},[75,1339,1340,1346,1352,1358,1364,1370,1376,1382,1388,1394],{},[65,1341,1342,1344],{},[80,1343,82],{},[80,1345,85],{},[65,1347,1348,1350],{},[80,1349,90],{},[80,1351,93],{},[65,1353,1354,1356],{},[80,1355,98],{},[80,1357,101],{},[65,1359,1360,1362],{},[80,1361,106],{},[80,1363,93],{},[65,1365,1366,1368],{},[80,1367,113],{},[80,1369,116],{},[65,1371,1372,1374],{},[80,1373,121],{},[80,1375,93],{},[65,1377,1378,1380],{},[80,1379,128],{},[80,1381,116],{},[65,1383,1384,1386],{},[80,1385,135],{},[80,1387,138],{},[65,1389,1390,1392],{},[80,1391,143],{},[80,1393,93],{},[65,1395,1396,1398],{},[80,1397,150],{},[80,1399,93],{},[27,1401,156],{"id":155},[15,1403,159],{},[59,1405,1406,1418],{},[62,1407,1408],{},[65,1409,1410,1412,1414,1416],{},[68,1411,168],{},[68,1413,171],{},[68,1415,174],{},[68,1417,177],{},[75,1419,1420,1430,1440,1450],{},[65,1421,1422,1424,1426,1428],{},[80,1423,184],{},[80,1425,187],{},[80,1427,190],{},[80,1429,190],{},[65,1431,1432,1434,1436,1438],{},[80,1433,197],{},[80,1435,200],{},[80,1437,190],{},[80,1439,205],{},[65,1441,1442,1444,1446,1448],{},[80,1443,210],{},[80,1445,213],{},[80,1447,190],{},[80,1449,218],{},[65,1451,1452,1454,1456,1458],{},[80,1453,223],{},[80,1455,226],{},[80,1457,190],{},[80,1459,231],{},[233,1461,1462],{},[15,1463,1464],{},[35,1465,239],{},[19,1467],{},[22,1469,245],{"id":244},[15,1471,248],{},[59,1473,1474,1484],{},[62,1475,1476],{},[65,1477,1478,1480,1482],{},[68,1479,257],{},[68,1481,260],{},[68,1483,263],{},[75,1485,1486,1494,1502,1510,1518,1526,1534,1542,1550,1558,1566,1574,1582],{},[65,1487,1488,1490,1492],{},[80,1489,270],{},[80,1491,273],{},[80,1493,276],{},[65,1495,1496,1498,1500],{},[80,1497,281],{},[80,1499,284],{},[80,1501,287],{},[65,1503,1504,1506,1508],{},[80,1505,292],{},[80,1507,187],{},[80,1509,297],{},[65,1511,1512,1514,1516],{},[80,1513,302],{},[80,1515,187],{},[80,1517,307],{},[65,1519,1520,1522,1524],{},[80,1521,312],{},[80,1523,187],{},[80,1525,287],{},[65,1527,1528,1530,1532],{},[80,1529,321],{},[80,1531,187],{},[80,1533,287],{},[65,1535,1536,1538,1540],{},[80,1537,330],{},[80,1539,187],{},[80,1541,287],{},[65,1543,1544,1546,1548],{},[80,1545,339],{},[80,1547,187],{},[80,1549,287],{},[65,1551,1552,1554,1556],{},[80,1553,348],{},[80,1555,187],{},[80,1557,287],{},[65,1559,1560,1562,1564],{},[80,1561,357],{},[80,1563,187],{},[80,1565,362],{},[65,1567,1568,1570,1572],{},[80,1569,367],{},[80,1571,187],{},[80,1573,287],{},[65,1575,1576,1578,1580],{},[80,1577,376],{},[80,1579,187],{},[80,1581,381],{},[65,1583,1584,1588,1592],{},[80,1585,1586],{},[35,1587,388],{},[80,1589,1590],{},[35,1591,393],{},[80,1593],{},[233,1595,1596],{},[15,1597,1598,403,1600,407],{},[35,1599,402],{},[35,1601,406],{},[19,1603],{},[22,1605,413],{"id":412},[15,1607,416,1608,420],{},[35,1609,419],{},[27,1611,424],{"id":423},[426,1613,1615],{"className":1614,"code":430,"language":431},[429],[433,1616,430],{"__ignoreMap":435},[233,1618,1619],{},[15,1620,1621,443],{},[35,1622,442],{},[27,1624,447],{"id":446},[59,1626,1627,1637],{},[62,1628,1629],{},[65,1630,1631,1633,1635],{},[68,1632,257],{},[68,1634,458],{},[68,1636,461],{},[75,1638,1639,1649,1659,1669],{},[65,1640,1641,1645,1647],{},[80,1642,1643],{},[35,1644,470],{},[80,1646,473],{},[80,1648,476],{},[65,1650,1651,1655,1657],{},[80,1652,1653],{},[35,1654,483],{},[80,1656,486],{},[80,1658,489],{},[65,1660,1661,1665,1667],{},[80,1662,1663],{},[35,1664,496],{},[80,1666,499],{},[80,1668,502],{},[65,1670,1671,1675,1677],{},[80,1672,1673],{},[35,1674,509],{},[80,1676,512],{},[80,1678,515],{},[27,1680,519],{"id":518},[15,1682,522,1683,526],{},[35,1684,525],{},[19,1686],{},[22,1688,532],{"id":531},[27,1690,536],{"id":535},[15,1692,539,1693,543],{},[35,1694,542],{},[27,1696,547],{"id":546},[59,1698,1699,1707],{},[62,1700,1701],{},[65,1702,1703,1705],{},[68,1704,41],{},[68,1706,558],{},[75,1708,1709,1717,1725,1733],{},[65,1710,1711,1715],{},[80,1712,1713],{},[35,1714,567],{},[80,1716,570],{},[65,1718,1719,1723],{},[80,1720,1721],{},[35,1722,577],{},[80,1724,580],{},[65,1726,1727,1731],{},[80,1728,1729],{},[35,1730,587],{},[80,1732,590],{},[65,1734,1735,1739],{},[80,1736,1737],{},[35,1738,597],{},[80,1740,600],{},[19,1742],{},[22,1744,606],{"id":605},[15,1746,609,1747,613],{},[35,1748,612],{},[615,1750,1751,1753],{},[618,1752,620],{},[618,1754,623,1755,627],{},[35,1756,626],{},[15,1758,1759],{},[35,1760,632],{},[615,1762,1763,1765,1767],{},[618,1764,637],{},[618,1766,640],{},[618,1768,643],{},[19,1770],{},[22,1772,649],{"id":648},[15,1774,652],{},[27,1776,656],{"id":655},[59,1778,1779,1791],{},[62,1780,1781],{},[65,1782,1783,1785,1787,1789],{},[68,1784,665],{},[68,1786,70],{},[68,1788,52],{},[68,1790,672],{},[75,1792,1793,1803,1813,1823,1833],{},[65,1794,1795,1797,1799,1801],{},[80,1796,679],{},[80,1798,682],{},[80,1800,200],{},[80,1802,687],{},[65,1804,1805,1807,1809,1811],{},[80,1806,692],{},[80,1808,695],{},[80,1810,200],{},[80,1812,470],{},[65,1814,1815,1817,1819,1821],{},[80,1816,704],{},[80,1818,707],{},[80,1820,226],{},[80,1822,712],{},[65,1824,1825,1827,1829,1831],{},[80,1826,717],{},[80,1828,143],{},[80,1830,200],{},[80,1832,724],{},[65,1834,1835,1837,1839,1841],{},[80,1836,729],{},[80,1838,732],{},[80,1840,735],{},[80,1842,626],{},[27,1844,741],{"id":740},[59,1846,1847,1859],{},[62,1848,1849],{},[65,1850,1851,1853,1855,1857],{},[68,1852,665],{},[68,1854,70],{},[68,1856,52],{},[68,1858,672],{},[75,1860,1861,1871,1881,1891,1901,1911,1921,1931],{},[65,1862,1863,1865,1867,1869],{},[80,1864,679],{},[80,1866,764],{},[80,1868,200],{},[80,1870,769],{},[65,1872,1873,1875,1877,1879],{},[80,1874,213],{},[80,1876,776],{},[80,1878,187],{},[80,1880,781],{},[65,1882,1883,1885,1887,1889],{},[80,1884,226],{},[80,1886,776],{},[80,1888,187],{},[80,1890,792],{},[65,1892,1893,1895,1897,1899],{},[80,1894,797],{},[80,1896,776],{},[80,1898,187],{},[80,1900,804],{},[65,1902,1903,1905,1907,1909],{},[80,1904,809],{},[80,1906,812],{},[80,1908,187],{},[80,1910,817],{},[65,1912,1913,1915,1917,1919],{},[80,1914,822],{},[80,1916,812],{},[80,1918,187],{},[80,1920,829],{},[65,1922,1923,1925,1927,1929],{},[80,1924,735],{},[80,1926,812],{},[80,1928,187],{},[80,1930,840],{},[65,1932,1933,1935,1937,1939],{},[80,1934,845],{},[80,1936,732],{},[80,1938,850],{},[80,1940,626],{},[27,1942,856],{"id":855},[59,1944,1945,1957],{},[62,1946,1947],{},[65,1948,1949,1951,1953,1955],{},[68,1950,665],{},[68,1952,70],{},[68,1954,52],{},[68,1956,672],{},[75,1958,1959,1969,1979,1989,1999,2009,2019,2029],{},[65,1960,1961,1963,1965,1967],{},[80,1962,679],{},[80,1964,764],{},[80,1966,200],{},[80,1968,769],{},[65,1970,1971,1973,1975,1977],{},[80,1972,213],{},[80,1974,812],{},[80,1976,187],{},[80,1978,893],{},[65,1980,1981,1983,1985,1987],{},[80,1982,226],{},[80,1984,900],{},[80,1986,187],{},[80,1988,905],{},[65,1990,1991,1993,1995,1997],{},[80,1992,797],{},[80,1994,812],{},[80,1996,187],{},[80,1998,916],{},[65,2000,2001,2003,2005,2007],{},[80,2002,809],{},[80,2004,812],{},[80,2006,187],{},[80,2008,927],{},[65,2010,2011,2013,2015,2017],{},[80,2012,822],{},[80,2014,812],{},[80,2016,187],{},[80,2018,938],{},[65,2020,2021,2023,2025,2027],{},[80,2022,735],{},[80,2024,812],{},[80,2026,187],{},[80,2028,949],{},[65,2030,2031,2033,2035,2037],{},[80,2032,845],{},[80,2034,732],{},[80,2036,850],{},[80,2038,626],{},[27,2040,963],{"id":962},[59,2042,2043,2055],{},[62,2044,2045],{},[65,2046,2047,2049,2051,2053],{},[68,2048,665],{},[68,2050,70],{},[68,2052,52],{},[68,2054,672],{},[75,2056,2057,2067,2077,2087,2097,2107,2117,2127],{},[65,2058,2059,2061,2063,2065],{},[80,2060,679],{},[80,2062,764],{},[80,2064,200],{},[80,2066,769],{},[65,2068,2069,2071,2073,2075],{},[80,2070,213],{},[80,2072,812],{},[80,2074,187],{},[80,2076,1000],{},[65,2078,2079,2081,2083,2085],{},[80,2080,226],{},[80,2082,812],{},[80,2084,187],{},[80,2086,1011],{},[65,2088,2089,2091,2093,2095],{},[80,2090,797],{},[80,2092,812],{},[80,2094,187],{},[80,2096,1022],{},[65,2098,2099,2101,2103,2105],{},[80,2100,809],{},[80,2102,900],{},[80,2104,187],{},[80,2106,1033],{},[65,2108,2109,2111,2113,2115],{},[80,2110,822],{},[80,2112,812],{},[80,2114,187],{},[80,2116,348],{},[65,2118,2119,2121,2123,2125],{},[80,2120,735],{},[80,2122,812],{},[80,2124,187],{},[80,2126,367],{},[65,2128,2129,2131,2133,2135],{},[80,2130,845],{},[80,2132,732],{},[80,2134,850],{},[80,2136,626],{},[15,2138,2139],{},[35,2140,1068],{},[19,2142],{},[22,2144,1074],{"id":1073},[59,2146,2147,2157],{},[62,2148,2149],{},[65,2150,2151,2153,2155],{},[68,2152,1083],{},[68,2154,1086],{},[68,2156,1089],{},[75,2158,2159,2167,2175,2183,2191,2199,2207],{},[65,2160,2161,2163,2165],{},[80,2162,1096],{},[80,2164,1099],{},[80,2166,1102],{},[65,2168,2169,2171,2173],{},[80,2170,1107],{},[80,2172,1110],{},[80,2174,1113],{},[65,2176,2177,2179,2181],{},[80,2178,1118],{},[80,2180,1121],{},[80,2182,1124],{},[65,2184,2185,2187,2189],{},[80,2186,1129],{},[80,2188,1132],{},[80,2190,1135],{},[65,2192,2193,2195,2197],{},[80,2194,1140],{},[80,2196,1143],{},[80,2198,1146],{},[65,2200,2201,2203,2205],{},[80,2202,1151],{},[80,2204,1154],{},[80,2206,1157],{},[65,2208,2209,2211,2213],{},[80,2210,1162],{},[80,2212,1165],{},[80,2214,1168],{},[19,2216],{},[22,2218,1174],{"id":1173},[15,2220,1177,2221,1181],{},[35,2222,1180],{},[615,2224,2225,2227,2229],{},[618,2226,1186],{},[618,2228,1189],{},[618,2230,1192],{},[15,2232,1195,2233,1199],{},[35,2234,1198],{},[19,2236],{},[22,2238,1205],{"id":1204},[615,2240,2241,2245,2249,2253],{},[618,2242,2243],{},[1211,2244,1214],{"href":1213},[618,2246,2247],{},[1211,2248,1220],{"href":1219},[618,2250,2251],{},[1211,2252,1226],{"href":1225},[618,2254,2255],{},[1211,2256,1232],{"href":1231},[19,2258],{},[15,2260,2261],{},[1238,2262,1240,2263,1244,2265],{},[35,2264,1243],{},[1211,2266,1248],{"href":1247},{"title":435,"searchDepth":1250,"depth":1250,"links":2268},[2269,2274,2275,2280,2284,2285,2291,2292,2293],{"id":24,"depth":1250,"text":25,"children":2270},[2271,2272,2273],{"id":29,"depth":1255,"text":30},{"id":45,"depth":1255,"text":46},{"id":155,"depth":1255,"text":156},{"id":244,"depth":1250,"text":245},{"id":412,"depth":1250,"text":413,"children":2276},[2277,2278,2279],{"id":423,"depth":1255,"text":424},{"id":446,"depth":1255,"text":447},{"id":518,"depth":1255,"text":519},{"id":531,"depth":1250,"text":532,"children":2281},[2282,2283],{"id":535,"depth":1255,"text":536},{"id":546,"depth":1255,"text":547},{"id":605,"depth":1250,"text":606},{"id":648,"depth":1250,"text":649,"children":2286},[2287,2288,2289,2290],{"id":655,"depth":1255,"text":656},{"id":740,"depth":1255,"text":741},{"id":855,"depth":1255,"text":856},{"id":962,"depth":1255,"text":963},{"id":1073,"depth":1250,"text":1074},{"id":1173,"depth":1250,"text":1174},{"id":1204,"depth":1250,"text":1205},{},{"title":5,"description":1280},[1292,1293,1294,1295,263,1296,1297,1298],{"id":2298,"title":2299,"articleId":6,"body":2300,"category":1278,"date":1279,"description":3501,"extension":1281,"lastUpdated":1279,"locale":3502,"meta":3503,"navigation":1284,"path":3504,"publishDate":1279,"readTime":1286,"refreshInterval":1287,"seo":3505,"slug":3506,"stem":3507,"tags":3508,"__hash__":3514},"blog\u002Fblog\u002Fdistribution-board-planning.en.md","Distribution Board Planning: Layout and Sizing According to AREI\u002FRGIE",{"type":8,"value":2301,"toc":3474},[2302,2305,2308,2310,2314,2318,2329,2333,2342,2426,2430,2433,2497,2504,2506,2510,2513,2656,2668,2670,2674,2681,2685,2691,2695,2763,2767,2774,2776,2780,2784,2791,2795,2849,2851,2855,2862,2874,2879,2890,2892,2896,2899,2903,2976,2980,3084,3088,3190,3194,3293,3298,3300,3304,3398,3400,3404,3411,3422,3429,3431,3435,3461,3463],[11,2303,2299],{"id":2304},"distribution-board-planning-layout-and-sizing-according-to-areirgie",[15,2306,2307],{},"The distribution board (also called consumer unit, fuse box, or electrical panel) is the heart of every electrical installation. This is where all circuits converge, where the protection devices sit that protect your home and family from electrical hazards. Thoughtful planning not only saves money but also prevents problems during the AREI\u002FRGIE inspection.",[19,2309],{},[22,2311,2313],{"id":2312},"fundamentals-structure-of-a-distribution-board","Fundamentals: Structure of a Distribution Board",[27,2315,2317],{"id":2316},"din-rail-omega-rail","DIN Rail (Omega Rail)",[15,2319,2320,2321,2324,2325,2328],{},"All modules in the board are snapped onto standardised ",[35,2322,2323],{},"DIN rails"," (35 mm omega rail per EN 60715). Each rail forms a ",[35,2326,2327],{},"row"," in the board.",[27,2330,2332],{"id":2331},"module-units-te-units","Module Units (TE Units)",[15,2334,2335,2336,2338,2339,2341],{},"Module width is measured in ",[35,2337,52],{}," (Teilungseinheiten \u002F division units). One TE equals ",[35,2340,56],{},". Typical widths:",[59,2343,2344,2354],{},[62,2345,2346],{},[65,2347,2348,2351],{},[68,2349,2350],{},"Module",[68,2352,2353],{},"Width (TE)",[75,2355,2356,2363,2370,2377,2384,2391,2398,2405,2412,2419],{},[65,2357,2358,2361],{},[80,2359,2360],{},"MCB 1-pole",[80,2362,85],{},[65,2364,2365,2368],{},[80,2366,2367],{},"MCB 2-pole",[80,2369,93],{},[65,2371,2372,2375],{},[80,2373,2374],{},"MCB 3-pole",[80,2376,101],{},[65,2378,2379,2382],{},[80,2380,2381],{},"RCD 2-pole (30 mA \u002F 300 mA)",[80,2383,93],{},[65,2385,2386,2389],{},[80,2387,2388],{},"RCD 4-pole",[80,2390,116],{},[65,2392,2393,2396],{},[80,2394,2395],{},"Main switch 2-pole",[80,2397,93],{},[65,2399,2400,2403],{},[80,2401,2402],{},"Main switch 4-pole",[80,2404,116],{},[65,2406,2407,2410],{},[80,2408,2409],{},"SPD (Surge Protection)",[80,2411,138],{},[65,2413,2414,2417],{},[80,2415,2416],{},"Bell transformer",[80,2418,93],{},[65,2420,2421,2424],{},[80,2422,2423],{},"Timer switch",[80,2425,93],{},[27,2427,2429],{"id":2428},"board-sizes","Board Sizes",[15,2431,2432],{},"Boards are sized by rows and TE per row:",[59,2434,2435,2451],{},[62,2436,2437],{},[65,2438,2439,2442,2445,2448],{},[68,2440,2441],{},"Description",[68,2443,2444],{},"Rows",[68,2446,2447],{},"TE per row",[68,2449,2450],{},"Total TE",[75,2452,2453,2464,2475,2486],{},[65,2454,2455,2458,2460,2462],{},[80,2456,2457],{},"1-row",[80,2459,187],{},[80,2461,190],{},[80,2463,190],{},[65,2465,2466,2469,2471,2473],{},[80,2467,2468],{},"2-row",[80,2470,200],{},[80,2472,190],{},[80,2474,205],{},[65,2476,2477,2480,2482,2484],{},[80,2478,2479],{},"3-row",[80,2481,213],{},[80,2483,190],{},[80,2485,218],{},[65,2487,2488,2491,2493,2495],{},[80,2489,2490],{},"4-row",[80,2492,226],{},[80,2494,190],{},[80,2496,231],{},[233,2498,2499],{},[15,2500,2501],{},[35,2502,2503],{},"For a typical single-family home, we recommend at least a 4-row board with 18 TE per row (72 TE total).",[19,2505],{},[22,2507,2509],{"id":2508},"step-1-count-your-circuits","Step 1: Count Your Circuits",[15,2511,2512],{},"List all required circuits. For an average single-family home (3 bedrooms, 150 m²):",[59,2514,2515,2527],{},[62,2516,2517],{},[65,2518,2519,2522,2525],{},[68,2520,2521],{},"Type",[68,2523,2524],{},"Count",[68,2526,263],{},[75,2528,2529,2540,2550,2560,2570,2579,2588,2597,2606,2615,2625,2633,2642],{},[65,2530,2531,2534,2537],{},[80,2532,2533],{},"Lighting",[80,2535,2536],{},"3–4 circuits",[80,2538,2539],{},"B10A or B16A",[65,2541,2542,2545,2548],{},[80,2543,2544],{},"General sockets",[80,2546,2547],{},"4–6 circuits",[80,2549,287],{},[65,2551,2552,2555,2557],{},[80,2553,2554],{},"Kitchen dedicated (oven)",[80,2556,187],{},[80,2558,2559],{},"B20A or B32A",[65,2561,2562,2565,2567],{},[80,2563,2564],{},"Kitchen dedicated (hob)",[80,2566,187],{},[80,2568,2569],{},"B32A (3-phase if needed)",[65,2571,2572,2575,2577],{},[80,2573,2574],{},"Kitchen dedicated (dishwasher)",[80,2576,187],{},[80,2578,287],{},[65,2580,2581,2584,2586],{},[80,2582,2583],{},"Washing machine",[80,2585,187],{},[80,2587,287],{},[65,2589,2590,2593,2595],{},[80,2591,2592],{},"Tumble dryer",[80,2594,187],{},[80,2596,287],{},[65,2598,2599,2602,2604],{},[80,2600,2601],{},"Bathroom sockets",[80,2603,187],{},[80,2605,287],{},[65,2607,2608,2611,2613],{},[80,2609,2610],{},"Outdoor sockets",[80,2612,187],{},[80,2614,287],{},[65,2616,2617,2620,2622],{},[80,2618,2619],{},"Water heater \u002F boiler",[80,2621,187],{},[80,2623,2624],{},"B16A or B20A",[65,2626,2627,2629,2631],{},[80,2628,367],{},[80,2630,187],{},[80,2632,287],{},[65,2634,2635,2638,2640],{},[80,2636,2637],{},"EV charger (if applicable)",[80,2639,187],{},[80,2641,381],{},[65,2643,2644,2649,2654],{},[80,2645,2646],{},[35,2647,2648],{},"Total",[80,2650,2651],{},[35,2652,2653],{},"17–21 circuits",[80,2655],{},[233,2657,2658],{},[15,2659,2660,2663,2664,2667],{},[35,2661,2662],{},"Tip:"," Maximum ",[35,2665,2666],{},"8 single or multiple socket outlets"," per final circuit (AREI Art. 5.3.5.2b). Lighting circuits may have more points, but in practice max. 8 luminaires per circuit is recommended.",[19,2669],{},[22,2671,2673],{"id":2672},"step-2-choose-protection-devices","Step 2: Choose Protection Devices",[15,2675,2676,2677,2680],{},"Protection devices are arranged ",[35,2678,2679],{},"hierarchically"," — from the supply (top) downward:",[27,2682,2684],{"id":2683},"protection-hierarchy","Protection Hierarchy",[426,2686,2689],{"className":2687,"code":2688,"language":431},[429],"Main switch (40A or 63A)\n   └── Main RCD 300 mA (Type A-S, selective)\n        ├── Group RCD 30 mA #1 (Type A)\n        │    ├── MCB Lighting ground floor (B10A)\n        │    ├── MCB Lighting first floor (B10A)\n        │    ├── MCB Sockets living room (B16A)\n        │    └── MCB Sockets hallway (B16A)\n        ├── Group RCD 30 mA #2 (Type A)\n        │    ├── MCB Sockets kitchen (B16A)\n        │    ├── MCB Oven (B20A)\n        │    ├── MCB Dishwasher (B16A)\n        │    └── MCB Sockets bedrooms (B16A)\n        └── Group RCD 30 mA #3 (Type A)\n             ├── MCB Washing machine (B16A)\n             ├── MCB Bathroom (B16A)\n             ├── MCB Outdoor (B16A)\n             └── MCB Garage (B16A)\n",[433,2690,2688],{"__ignoreMap":435},[27,2692,2694],{"id":2693},"rcd-types","RCD Types",[59,2696,2697,2709],{},[62,2698,2699],{},[65,2700,2701,2703,2706],{},[68,2702,2521],{},[68,2704,2705],{},"Trip current",[68,2707,2708],{},"Application",[75,2710,2711,2724,2737,2750],{},[65,2712,2713,2718,2721],{},[80,2714,2715],{},[35,2716,2717],{},"300 mA Type A-S",[80,2719,2720],{},"300 mA, selective (time-delayed)",[80,2722,2723],{},"Main RCD, trips only on fault downstream of group RCDs",[65,2725,2726,2731,2734],{},[80,2727,2728],{},[35,2729,2730],{},"30 mA Type A",[80,2732,2733],{},"30 mA, instantaneous",[80,2735,2736],{},"Group RCD, personal protection",[65,2738,2739,2744,2747],{},[80,2740,2741],{},[35,2742,2743],{},"30 mA Type B",[80,2745,2746],{},"30 mA, all-current sensitive",[80,2748,2749],{},"For EV charger \u002F inverter with DC component",[65,2751,2752,2757,2760],{},[80,2753,2754],{},[35,2755,2756],{},"30 mA Type F",[80,2758,2759],{},"30 mA, frequency-independent",[80,2761,2762],{},"For variable frequency drives (heat pump)",[27,2764,2766],{"id":2765},"selectivity","Selectivity",[15,2768,2769,2770,2773],{},"The main RCD (300 mA, ",[35,2771,2772],{},"Type S"," = selective) is time-delayed and only trips when the group RCD (30 mA) has failed to respond. This means that in case of a fault, only the affected group RCD trips — not the entire installation.",[19,2775],{},[22,2777,2779],{"id":2778},"step-3-allocate-to-rows","Step 3: Allocate to Rows",[27,2781,2783],{"id":2782},"arei-rule-max-8-final-circuits-per-rcd","AREI Rule: Max. 8 Final Circuits per RCD",[15,2785,2786,2787,2790],{},"According to AREI Art. 4.2.4.3b, a maximum of ",[35,2788,2789],{},"8 final circuits"," may be connected downstream of one residual current device (RCD). In practice, 4–6 circuits per RCD are recommended for comfortable reserve.",[27,2792,2794],{"id":2793},"typical-row-allocation","Typical Row Allocation",[59,2796,2797,2807],{},[62,2798,2799],{},[65,2800,2801,2804],{},[68,2802,2803],{},"Row",[68,2805,2806],{},"Contents",[75,2808,2809,2819,2829,2839],{},[65,2810,2811,2816],{},[80,2812,2813],{},[35,2814,2815],{},"Row 1",[80,2817,2818],{},"Main switch, Main RCD (300 mA), SPD, bell transformer if needed",[65,2820,2821,2826],{},[80,2822,2823],{},[35,2824,2825],{},"Row 2",[80,2827,2828],{},"Group RCD #1 (30 mA) + associated MCBs (lighting + living area sockets)",[65,2830,2831,2836],{},[80,2832,2833],{},[35,2834,2835],{},"Row 3",[80,2837,2838],{},"Group RCD #2 (30 mA) + associated MCBs (kitchen + bedrooms)",[65,2840,2841,2846],{},[80,2842,2843],{},[35,2844,2845],{},"Row 4",[80,2847,2848],{},"Group RCD #3 (30 mA) + associated MCBs (bathroom, outdoor, garage, utility)",[19,2850],{},[22,2852,2854],{"id":2853},"step-4-plan-reserve-spaces","Step 4: Plan Reserve Spaces",[15,2856,2857,2858,2861],{},"Plan at least ",[35,2859,2860],{},"20% reserve spaces"," — ideally 30%. This means:",[615,2863,2864,2867],{},[618,2865,2866],{},"With 20 required MCBs → at least 4–6 free TE spaces.",[618,2868,2869,2870,2873],{},"Empty spaces are closed with ",[35,2871,2872],{},"blanking plates",".",[15,2875,2876],{},[35,2877,2878],{},"Why?",[615,2880,2881,2884,2887],{},[618,2882,2883],{},"Future additions (EV charger, air conditioning, sauna).",[618,2885,2886],{},"Redistribution if an RCD has too many circuits.",[618,2888,2889],{},"Avoiding an expensive board replacement.",[19,2891],{},[22,2893,2895],{"id":2894},"example-layout-4-row-board-for-a-single-family-home","Example Layout: 4-Row Board for a Single-Family Home",[15,2897,2898],{},"Here is a complete example for a typical Belgian single-family home (3 BR, 150 m², no PV):",[27,2900,2902],{"id":2901},"row-1-supply-protection-18-te","Row 1 — Supply & Protection (18 TE)",[59,2904,2905,2918],{},[62,2906,2907],{},[65,2908,2909,2911,2913,2915],{},[68,2910,665],{},[68,2912,2350],{},[68,2914,52],{},[68,2916,2917],{},"Function",[75,2919,2920,2932,2943,2954,2965],{},[65,2921,2922,2924,2927,2929],{},[80,2923,679],{},[80,2925,2926],{},"Main switch 2P",[80,2928,200],{},[80,2930,2931],{},"40A main switch",[65,2933,2934,2936,2939,2941],{},[80,2935,692],{},[80,2937,2938],{},"Main RCD 2P",[80,2940,200],{},[80,2942,2717],{},[65,2944,2945,2947,2949,2951],{},[80,2946,704],{},[80,2948,707],{},[80,2950,226],{},[80,2952,2953],{},"Surge protection",[65,2955,2956,2958,2960,2962],{},[80,2957,717],{},[80,2959,2416],{},[80,2961,200],{},[80,2963,2964],{},"8V doorbell",[65,2966,2967,2969,2971,2973],{},[80,2968,729],{},[80,2970,732],{},[80,2972,735],{},[80,2974,2975],{},"Blanking plates",[27,2977,2979],{"id":2978},"row-2-group-1-lighting-living-area-18-te","Row 2 — Group 1: Lighting + Living Area (18 TE)",[59,2981,2982,2994],{},[62,2983,2984],{},[65,2985,2986,2988,2990,2992],{},[68,2987,665],{},[68,2989,2350],{},[68,2991,52],{},[68,2993,2917],{},[75,2995,2996,3008,3019,3030,3041,3052,3063,3074],{},[65,2997,2998,3000,3003,3005],{},[80,2999,679],{},[80,3001,3002],{},"Group RCD 30 mA",[80,3004,200],{},[80,3006,3007],{},"Type A",[65,3009,3010,3012,3014,3016],{},[80,3011,213],{},[80,3013,776],{},[80,3015,187],{},[80,3017,3018],{},"Lighting ground floor",[65,3020,3021,3023,3025,3027],{},[80,3022,226],{},[80,3024,776],{},[80,3026,187],{},[80,3028,3029],{},"Lighting first floor",[65,3031,3032,3034,3036,3038],{},[80,3033,797],{},[80,3035,776],{},[80,3037,187],{},[80,3039,3040],{},"Lighting basement\u002Foutdoor",[65,3042,3043,3045,3047,3049],{},[80,3044,809],{},[80,3046,812],{},[80,3048,187],{},[80,3050,3051],{},"Sockets living room",[65,3053,3054,3056,3058,3060],{},[80,3055,822],{},[80,3057,812],{},[80,3059,187],{},[80,3061,3062],{},"Sockets dining room",[65,3064,3065,3067,3069,3071],{},[80,3066,735],{},[80,3068,812],{},[80,3070,187],{},[80,3072,3073],{},"Sockets hallway",[65,3075,3076,3078,3080,3082],{},[80,3077,845],{},[80,3079,732],{},[80,3081,850],{},[80,3083,2975],{},[27,3085,3087],{"id":3086},"row-3-group-2-kitchen-bedrooms-18-te","Row 3 — Group 2: Kitchen + Bedrooms (18 TE)",[59,3089,3090,3102],{},[62,3091,3092],{},[65,3093,3094,3096,3098,3100],{},[68,3095,665],{},[68,3097,2350],{},[68,3099,52],{},[68,3101,2917],{},[75,3103,3104,3114,3125,3136,3147,3158,3169,3180],{},[65,3105,3106,3108,3110,3112],{},[80,3107,679],{},[80,3109,3002],{},[80,3111,200],{},[80,3113,3007],{},[65,3115,3116,3118,3120,3122],{},[80,3117,213],{},[80,3119,812],{},[80,3121,187],{},[80,3123,3124],{},"Kitchen sockets",[65,3126,3127,3129,3131,3133],{},[80,3128,226],{},[80,3130,900],{},[80,3132,187],{},[80,3134,3135],{},"Oven (dedicated)",[65,3137,3138,3140,3142,3144],{},[80,3139,797],{},[80,3141,812],{},[80,3143,187],{},[80,3145,3146],{},"Dishwasher (dedicated)",[65,3148,3149,3151,3153,3155],{},[80,3150,809],{},[80,3152,812],{},[80,3154,187],{},[80,3156,3157],{},"Refrigerator (dedicated)",[65,3159,3160,3162,3164,3166],{},[80,3161,822],{},[80,3163,812],{},[80,3165,187],{},[80,3167,3168],{},"Sockets bedroom 1",[65,3170,3171,3173,3175,3177],{},[80,3172,735],{},[80,3174,812],{},[80,3176,187],{},[80,3178,3179],{},"Sockets bedrooms 2+3",[65,3181,3182,3184,3186,3188],{},[80,3183,845],{},[80,3185,732],{},[80,3187,850],{},[80,3189,2975],{},[27,3191,3193],{"id":3192},"row-4-group-3-bathroom-outdoor-utility-18-te","Row 4 — Group 3: Bathroom, Outdoor, Utility (18 TE)",[59,3195,3196,3208],{},[62,3197,3198],{},[65,3199,3200,3202,3204,3206],{},[68,3201,665],{},[68,3203,2350],{},[68,3205,52],{},[68,3207,2917],{},[75,3209,3210,3220,3230,3241,3252,3263,3273,3283],{},[65,3211,3212,3214,3216,3218],{},[80,3213,679],{},[80,3215,3002],{},[80,3217,200],{},[80,3219,3007],{},[65,3221,3222,3224,3226,3228],{},[80,3223,213],{},[80,3225,812],{},[80,3227,187],{},[80,3229,2601],{},[65,3231,3232,3234,3236,3238],{},[80,3233,226],{},[80,3235,812],{},[80,3237,187],{},[80,3239,3240],{},"Washing machine (dedicated)",[65,3242,3243,3245,3247,3249],{},[80,3244,797],{},[80,3246,812],{},[80,3248,187],{},[80,3250,3251],{},"Tumble dryer (dedicated)",[65,3253,3254,3256,3258,3260],{},[80,3255,809],{},[80,3257,900],{},[80,3259,187],{},[80,3261,3262],{},"Boiler (dedicated)",[65,3264,3265,3267,3269,3271],{},[80,3266,822],{},[80,3268,812],{},[80,3270,187],{},[80,3272,2610],{},[65,3274,3275,3277,3279,3281],{},[80,3276,735],{},[80,3278,812],{},[80,3280,187],{},[80,3282,367],{},[65,3284,3285,3287,3289,3291],{},[80,3286,845],{},[80,3288,732],{},[80,3290,850],{},[80,3292,2975],{},[15,3294,3295],{},[35,3296,3297],{},"Total: 24 MCBs + 4 RCDs + SPD + main switch = approx. 40 TE occupied out of 72 TE → 44% reserve",[19,3299],{},[22,3301,3303],{"id":3302},"common-mistakes-in-board-planning","Common Mistakes in Board Planning",[59,3305,3306,3319],{},[62,3307,3308],{},[65,3309,3310,3313,3316],{},[68,3311,3312],{},"Mistake",[68,3314,3315],{},"Consequence",[68,3317,3318],{},"Solution",[75,3320,3321,3332,3343,3354,3365,3376,3387],{},[65,3322,3323,3326,3329],{},[80,3324,3325],{},"Too few rows",[80,3327,3328],{},"No space for extensions",[80,3330,3331],{},"Min. 4 rows for a house",[65,3333,3334,3337,3340],{},[80,3335,3336],{},"No SPD (surge protection)",[80,3338,3339],{},"Recommended as good practice (Art. 4.5.1)",[80,3341,3342],{},"Include SPD",[65,3344,3345,3348,3351],{},[80,3346,3347],{},"More than 8 final circuits per RCD",[80,3349,3350],{},"AREI non-compliance (Art. 4.2.4.3b)",[80,3352,3353],{},"Add an additional group RCD",[65,3355,3356,3359,3362],{},[80,3357,3358],{},"Missing labels",[80,3360,3361],{},"Remark during inspection",[80,3363,3364],{},"Label every MCB (circuit number + function)",[65,3366,3367,3370,3373],{},[80,3368,3369],{},"No main RCD 300 mA",[80,3371,3372],{},"Missing selectivity",[80,3374,3375],{},"Always include a main RCD",[65,3377,3378,3381,3384],{},[80,3379,3380],{},"Wrong RCD type for EV charger",[80,3382,3383],{},"Incorrect tripping",[80,3385,3386],{},"Use Type B or Type A-EV",[65,3388,3389,3392,3395],{},[80,3390,3391],{},"No reserve",[80,3393,3394],{},"Expensive retrofit",[80,3396,3397],{},"Min. 20% free spaces",[19,3399],{},[22,3401,3403],{"id":3402},"labelling-and-documentation","Labelling and Documentation",[15,3405,3406,3407,3410],{},"Every MCB must be ",[35,3408,3409],{},"labelled"," with:",[615,3412,3413,3416,3419],{},[618,3414,3415],{},"Circuit number (identical to single-line diagram and situation plan)",[618,3417,3418],{},"Function (e.g., \"Lighting GF\", \"Kitchen sockets\")",[618,3420,3421],{},"Optional: room or floor",[15,3423,3424,3425,3428],{},"Apply the label ",[35,3426,3427],{},"inside the board cover"," or use a labelling strip. Most board manufacturers supply writable inserts.",[19,3430],{},[22,3432,3434],{"id":3433},"related-articles","Related Articles",[615,3436,3437,3443,3449,3455],{},[618,3438,3439],{},[1211,3440,3442],{"href":3441},"\u002Fen\u002Fblog\u002Fwhat-is-single-line-diagram","What Is a Single-Line Diagram?",[618,3444,3445],{},[1211,3446,3448],{"href":3447},"\u002Fen\u002Fblog\u002F30ma-rcd-per-socket","30 mA RCD Mandatory per Socket Circuit",[618,3450,3451],{},[1211,3452,3454],{"href":3453},"\u002Fen\u002Fblog\u002Fcable-cross-section-breaker","Cable Cross-Section and Breaker: The Right Combination",[618,3456,3457],{},[1211,3458,3460],{"href":3459},"\u002Fen\u002Fblog\u002Fpv-system-diagram","PV System in the Diagram",[19,3462],{},[15,3464,3465],{},[1238,3466,3467,3468,3470,3471],{},"Plan your distribution board visually with the ",[35,3469,1243],{}," — drag and drop modules onto the DIN rail, automatic AREI compliance check included. ",[1211,3472,3473],{"href":1247},"Try it now →",{"title":435,"searchDepth":1250,"depth":1250,"links":3475},[3476,3481,3482,3487,3491,3492,3498,3499,3500],{"id":2312,"depth":1250,"text":2313,"children":3477},[3478,3479,3480],{"id":2316,"depth":1255,"text":2317},{"id":2331,"depth":1255,"text":2332},{"id":2428,"depth":1255,"text":2429},{"id":2508,"depth":1250,"text":2509},{"id":2672,"depth":1250,"text":2673,"children":3483},[3484,3485,3486],{"id":2683,"depth":1255,"text":2684},{"id":2693,"depth":1255,"text":2694},{"id":2765,"depth":1255,"text":2766},{"id":2778,"depth":1250,"text":2779,"children":3488},[3489,3490],{"id":2782,"depth":1255,"text":2783},{"id":2793,"depth":1255,"text":2794},{"id":2853,"depth":1250,"text":2854},{"id":2894,"depth":1250,"text":2895,"children":3493},[3494,3495,3496,3497],{"id":2901,"depth":1255,"text":2902},{"id":2978,"depth":1255,"text":2979},{"id":3086,"depth":1255,"text":3087},{"id":3192,"depth":1255,"text":3193},{"id":3302,"depth":1250,"text":3303},{"id":3402,"depth":1250,"text":3403},{"id":3433,"depth":1250,"text":3434},"Complete guide to planning a distribution board. DIN rail, protection devices, row allocation, and example layout for a single-family home.","en",{},"\u002Fblog\u002Fdistribution-board-planning.en",{"title":2299,"description":3501},"distribution-board-planning-guide","blog\u002Fdistribution-board-planning.en",[3509,3510,3511,1295,263,1296,3512,3513],"distribution board","consumer unit","DIN rail","planning","single-family home","_mC2ARHmbYG-1em7cci8CcgzwUfIojDDbLDbwgC0Gzg",{"id":3516,"title":3517,"articleId":6,"body":3518,"category":1278,"date":1279,"description":4716,"extension":1281,"lastUpdated":1279,"locale":4717,"meta":4718,"navigation":1284,"path":4719,"publishDate":1279,"readTime":1286,"refreshInterval":1287,"seo":4720,"slug":4721,"stem":4722,"tags":4723,"__hash__":4730},"blog\u002Fblog\u002Fdistribution-board-planning.fr.md","Planifier un tableau électrique : Conception et dimensionnement selon le RGIE",{"type":8,"value":3519,"toc":4689},[3520,3523,3526,3528,3532,3536,3547,3551,3561,3649,3653,3656,3720,3727,3729,3733,3736,3875,3886,3888,3892,3899,3903,3909,3913,3976,3980,3986,3988,3992,3996,4003,4007,4061,4063,4067,4074,4085,4090,4101,4103,4107,4110,4114,4190,4194,4299,4303,4406,4410,4509,4514,4516,4520,4613,4615,4619,4626,4637,4644,4646,4650,4676,4678],[11,3521,3517],{"id":3522},"planifier-un-tableau-électrique-conception-et-dimensionnement-selon-le-rgie",[15,3524,3525],{},"Le tableau de distribution (aussi coffret électrique ou tableau divisionnaire) est le cœur de toute installation électrique. C'est là que tous les circuits convergent, c'est là que se trouvent les dispositifs de protection qui protègent votre habitation et votre famille contre les dangers électriques. Une planification réfléchie permet non seulement d'économiser de l'argent, mais aussi d'éviter les problèmes lors du contrôle RGIE.",[19,3527],{},[22,3529,3531],{"id":3530},"bases-structure-dun-tableau-de-distribution","Bases : Structure d'un tableau de distribution",[27,3533,3535],{"id":3534},"rail-din-rail-oméga","Rail DIN (rail oméga)",[15,3537,3538,3539,3542,3543,3546],{},"Tous les modules du tableau sont encliquetés sur des ",[35,3540,3541],{},"rails DIN"," standardisés (rail oméga 35 mm selon EN 60715). Chaque rail forme une ",[35,3544,3545],{},"rangée"," dans le tableau.",[27,3548,3550],{"id":3549},"modules-unités-de-division","Modules (unités de division)",[15,3552,3553,3554,3557,3558,3560],{},"La largeur d'un module est mesurée en ",[35,3555,3556],{},"modules"," (aussi appelés pas de 9 mm ou TE). Un module correspond à ",[35,3559,56],{},". Largeurs typiques :",[59,3562,3563,3572],{},[62,3564,3565],{},[65,3566,3567,3569],{},[68,3568,2350],{},[68,3570,3571],{},"Largeur (modules)",[75,3573,3574,3582,3590,3598,3605,3613,3620,3627,3635,3642],{},[65,3575,3576,3579],{},[80,3577,3578],{},"Disjoncteur 1 pôle",[80,3580,3581],{},"1 module",[65,3583,3584,3587],{},[80,3585,3586],{},"Disjoncteur 2 pôles",[80,3588,3589],{},"2 modules",[65,3591,3592,3595],{},[80,3593,3594],{},"Disjoncteur 3 pôles",[80,3596,3597],{},"3 modules",[65,3599,3600,3603],{},[80,3601,3602],{},"Différentiel 2 pôles (30 mA \u002F 300 mA)",[80,3604,3589],{},[65,3606,3607,3610],{},[80,3608,3609],{},"Différentiel 4 pôles",[80,3611,3612],{},"4 modules",[65,3614,3615,3618],{},[80,3616,3617],{},"Interrupteur principal 2 pôles",[80,3619,3589],{},[65,3621,3622,3625],{},[80,3623,3624],{},"Interrupteur principal 4 pôles",[80,3626,3612],{},[65,3628,3629,3632],{},[80,3630,3631],{},"Parafoudre (SPD)",[80,3633,3634],{},"2–4 modules",[65,3636,3637,3640],{},[80,3638,3639],{},"Transformateur de sonnerie",[80,3641,3589],{},[65,3643,3644,3647],{},[80,3645,3646],{},"Minuterie",[80,3648,3589],{},[27,3650,3652],{"id":3651},"dimensions-des-tableaux","Dimensions des tableaux",[15,3654,3655],{},"Les tableaux sont dimensionnés selon le nombre de rangées et de modules par rangée :",[59,3657,3658,3674],{},[62,3659,3660],{},[65,3661,3662,3665,3668,3671],{},[68,3663,3664],{},"Désignation",[68,3666,3667],{},"Rangées",[68,3669,3670],{},"Modules\u002Frangée",[68,3672,3673],{},"Total modules",[75,3675,3676,3687,3698,3709],{},[65,3677,3678,3681,3683,3685],{},[80,3679,3680],{},"1 rangée",[80,3682,187],{},[80,3684,190],{},[80,3686,190],{},[65,3688,3689,3692,3694,3696],{},[80,3690,3691],{},"2 rangées",[80,3693,200],{},[80,3695,190],{},[80,3697,205],{},[65,3699,3700,3703,3705,3707],{},[80,3701,3702],{},"3 rangées",[80,3704,213],{},[80,3706,190],{},[80,3708,218],{},[65,3710,3711,3714,3716,3718],{},[80,3712,3713],{},"4 rangées",[80,3715,226],{},[80,3717,190],{},[80,3719,231],{},[233,3721,3722],{},[15,3723,3724],{},[35,3725,3726],{},"Pour une maison unifamiliale typique, nous recommandons au minimum un tableau 4 rangées avec 18 modules par rangée (72 modules au total).",[19,3728],{},[22,3730,3732],{"id":3731},"étape-1-compter-les-circuits","Étape 1 : Compter les circuits",[15,3734,3735],{},"Listez tous les circuits nécessaires. Pour une maison unifamiliale moyenne (3 chambres, 150 m²) :",[59,3737,3738,3750],{},[62,3739,3740],{},[65,3741,3742,3744,3747],{},[68,3743,2521],{},[68,3745,3746],{},"Nombre",[68,3748,3749],{},"Disjoncteur",[75,3751,3752,3762,3771,3781,3791,3800,3809,3818,3827,3836,3846,3854,3863],{},[65,3753,3754,3757,3759],{},[80,3755,3756],{},"Éclairage",[80,3758,2536],{},[80,3760,3761],{},"B10A ou B16A",[65,3763,3764,3767,3769],{},[80,3765,3766],{},"Prises générales",[80,3768,2547],{},[80,3770,287],{},[65,3772,3773,3776,3778],{},[80,3774,3775],{},"Cuisine dédiée (four)",[80,3777,187],{},[80,3779,3780],{},"B20A ou B32A",[65,3782,3783,3786,3788],{},[80,3784,3785],{},"Cuisine dédiée (taque)",[80,3787,187],{},[80,3789,3790],{},"B32A (triphasé évent.)",[65,3792,3793,3796,3798],{},[80,3794,3795],{},"Cuisine dédiée (lave-vaisselle)",[80,3797,187],{},[80,3799,287],{},[65,3801,3802,3805,3807],{},[80,3803,3804],{},"Lave-linge",[80,3806,187],{},[80,3808,287],{},[65,3810,3811,3814,3816],{},[80,3812,3813],{},"Sèche-linge",[80,3815,187],{},[80,3817,287],{},[65,3819,3820,3823,3825],{},[80,3821,3822],{},"Prises salle de bain",[80,3824,187],{},[80,3826,287],{},[65,3828,3829,3832,3834],{},[80,3830,3831],{},"Prises extérieures",[80,3833,187],{},[80,3835,287],{},[65,3837,3838,3841,3843],{},[80,3839,3840],{},"Chauffe-eau \u002F boiler",[80,3842,187],{},[80,3844,3845],{},"B16A ou B20A",[65,3847,3848,3850,3852],{},[80,3849,367],{},[80,3851,187],{},[80,3853,287],{},[65,3855,3856,3859,3861],{},[80,3857,3858],{},"Borne de recharge (si présente)",[80,3860,187],{},[80,3862,381],{},[65,3864,3865,3869,3873],{},[80,3866,3867],{},[35,3868,2648],{},[80,3870,3871],{},[35,3872,2653],{},[80,3874],{},[233,3876,3877],{},[15,3878,3879,2663,3882,3885],{},[35,3880,3881],{},"Conseil :",[35,3883,3884],{},"8 prises simples ou multiples"," par circuit terminal (RGIE Art. 5.3.5.2b). Les circuits d'éclairage peuvent avoir plus de points, mais en pratique on recommande max. 8 luminaires par circuit.",[19,3887],{},[22,3889,3891],{"id":3890},"étape-2-choisir-les-dispositifs-de-protection","Étape 2 : Choisir les dispositifs de protection",[15,3893,3894,3895,3898],{},"Les dispositifs de protection sont disposés de manière ",[35,3896,3897],{},"hiérarchique"," — de l'alimentation (en haut) vers le bas :",[27,3900,3902],{"id":3901},"hiérarchie-des-protections","Hiérarchie des protections",[426,3904,3907],{"className":3905,"code":3906,"language":431},[429],"Interrupteur principal (40A ou 63A)\n   └── Différentiel principal 300 mA (Type A-S, sélectif)\n        ├── Différentiel groupe 30 mA #1 (Type A)\n        │    ├── Disj. Éclairage RDC (B10A)\n        │    ├── Disj. Éclairage étage (B10A)\n        │    ├── Disj. Prises séjour (B16A)\n        │    └── Disj. Prises couloir (B16A)\n        ├── Différentiel groupe 30 mA #2 (Type A)\n        │    ├── Disj. Prises cuisine (B16A)\n        │    ├── Disj. Four (B20A)\n        │    ├── Disj. Lave-vaisselle (B16A)\n        │    └── Disj. Prises chambres (B16A)\n        └── Différentiel groupe 30 mA #3 (Type A)\n             ├── Disj. Lave-linge (B16A)\n             ├── Disj. Salle de bain (B16A)\n             ├── Disj. Extérieur (B16A)\n             └── Disj. Garage (B16A)\n",[433,3908,3906],{"__ignoreMap":435},[27,3910,3912],{"id":3911},"types-de-différentiels","Types de différentiels",[59,3914,3915,3926],{},[62,3916,3917],{},[65,3918,3919,3921,3924],{},[68,3920,2521],{},[68,3922,3923],{},"Courant de déclenchement",[68,3925,2708],{},[75,3927,3928,3940,3952,3964],{},[65,3929,3930,3934,3937],{},[80,3931,3932],{},[35,3933,2717],{},[80,3935,3936],{},"300 mA, sélectif (temporisé)",[80,3938,3939],{},"Différentiel principal, déclenche uniquement en cas de défaut en aval",[65,3941,3942,3946,3949],{},[80,3943,3944],{},[35,3945,2730],{},[80,3947,3948],{},"30 mA, instantané",[80,3950,3951],{},"Différentiel de groupe, protection des personnes",[65,3953,3954,3958,3961],{},[80,3955,3956],{},[35,3957,2743],{},[80,3959,3960],{},"30 mA, tous courants",[80,3962,3963],{},"Pour borne de recharge \u002F onduleur avec composante CC",[65,3965,3966,3970,3973],{},[80,3967,3968],{},[35,3969,2756],{},[80,3971,3972],{},"30 mA, indépendant de la fréquence",[80,3974,3975],{},"Pour variateurs de fréquence (pompe à chaleur)",[27,3977,3979],{"id":3978},"sélectivité","Sélectivité",[15,3981,3982,3983,3985],{},"Le différentiel principal (300 mA, ",[35,3984,2772],{}," = sélectif) est temporisé et ne déclenche que lorsque le différentiel de groupe (30 mA) n'a pas réagi. Ainsi, en cas de défaut, seul le différentiel de groupe concerné se déclenche, pas toute l'installation.",[19,3987],{},[22,3989,3991],{"id":3990},"étape-3-répartition-en-rangées","Étape 3 : Répartition en rangées",[27,3993,3995],{"id":3994},"règle-rgie-max-8-circuits-terminaux-par-différentiel","Règle RGIE : Max. 8 circuits terminaux par différentiel",[15,3997,3998,3999,4002],{},"Selon le RGIE Art. 4.2.4.3b, un maximum de ",[35,4000,4001],{},"8 circuits terminaux"," peut être raccordé derrière un différentiel (RCD). En pratique, 4–6 circuits par différentiel sont recommandés pour une réserve confortable.",[27,4004,4006],{"id":4005},"répartition-typique-des-rangées","Répartition typique des rangées",[59,4008,4009,4019],{},[62,4010,4011],{},[65,4012,4013,4016],{},[68,4014,4015],{},"Rangée",[68,4017,4018],{},"Contenu",[75,4020,4021,4031,4041,4051],{},[65,4022,4023,4028],{},[80,4024,4025],{},[35,4026,4027],{},"Rangée 1",[80,4029,4030],{},"Interrupteur principal, Différentiel principal (300 mA), Parafoudre, évent. transfo sonnerie",[65,4032,4033,4038],{},[80,4034,4035],{},[35,4036,4037],{},"Rangée 2",[80,4039,4040],{},"Différentiel groupe #1 (30 mA) + disjoncteurs associés (éclairage + prises séjour)",[65,4042,4043,4048],{},[80,4044,4045],{},[35,4046,4047],{},"Rangée 3",[80,4049,4050],{},"Différentiel groupe #2 (30 mA) + disjoncteurs associés (cuisine + chambres)",[65,4052,4053,4058],{},[80,4054,4055],{},[35,4056,4057],{},"Rangée 4",[80,4059,4060],{},"Différentiel groupe #3 (30 mA) + disjoncteurs associés (SDB, extérieur, garage, technique)",[19,4062],{},[22,4064,4066],{"id":4065},"étape-4-prévoir-des-emplacements-de-réserve","Étape 4 : Prévoir des emplacements de réserve",[15,4068,4069,4070,4073],{},"Prévoyez au minimum ",[35,4071,4072],{},"20 % d'emplacements de réserve"," — idéalement 30 %. Cela signifie :",[615,4075,4076,4079],{},[618,4077,4078],{},"Pour 20 disjoncteurs nécessaires → au minimum 4–6 emplacements libres.",[618,4080,4081,4082,2873],{},"Les emplacements vides sont fermés par des ",[35,4083,4084],{},"obturateurs",[15,4086,4087],{},[35,4088,4089],{},"Pourquoi ?",[615,4091,4092,4095,4098],{},[618,4093,4094],{},"Extensions futures (borne de recharge, climatisation, sauna).",[618,4096,4097],{},"Redistribution si un différentiel a trop de circuits.",[618,4099,4100],{},"Éviter un remplacement coûteux du tableau.",[19,4102],{},[22,4104,4106],{"id":4105},"exemple-tableau-4-rangées-pour-maison-unifamiliale","Exemple : Tableau 4 rangées pour maison unifamiliale",[15,4108,4109],{},"Voici un exemple complet pour une maison belge typique (3 CH, 150 m², sans PV) :",[27,4111,4113],{"id":4112},"rangée-1-alimentation-protection-18-modules","Rangée 1 — Alimentation & protection (18 modules)",[59,4115,4116,4130],{},[62,4117,4118],{},[65,4119,4120,4122,4124,4127],{},[68,4121,665],{},[68,4123,2350],{},[68,4125,4126],{},"Modules",[68,4128,4129],{},"Fonction",[75,4131,4132,4144,4155,4166,4178],{},[65,4133,4134,4136,4139,4141],{},[80,4135,679],{},[80,4137,4138],{},"Interrupteur principal 2P",[80,4140,200],{},[80,4142,4143],{},"40A interrupteur principal",[65,4145,4146,4148,4151,4153],{},[80,4147,692],{},[80,4149,4150],{},"Différentiel principal 2P",[80,4152,200],{},[80,4154,2717],{},[65,4156,4157,4159,4161,4163],{},[80,4158,704],{},[80,4160,3631],{},[80,4162,226],{},[80,4164,4165],{},"Protection contre les surtensions",[65,4167,4168,4170,4173,4175],{},[80,4169,717],{},[80,4171,4172],{},"Transfo sonnerie",[80,4174,200],{},[80,4176,4177],{},"Sonnerie 8V",[65,4179,4180,4182,4185,4187],{},[80,4181,729],{},[80,4183,4184],{},"Réserve",[80,4186,735],{},[80,4188,4189],{},"Obturateurs",[27,4191,4193],{"id":4192},"rangée-2-groupe-1-éclairage-séjour-18-modules","Rangée 2 — Groupe 1 : Éclairage + séjour (18 modules)",[59,4195,4196,4208],{},[62,4197,4198],{},[65,4199,4200,4202,4204,4206],{},[68,4201,665],{},[68,4203,2350],{},[68,4205,4126],{},[68,4207,4129],{},[75,4209,4210,4221,4233,4244,4255,4267,4278,4289],{},[65,4211,4212,4214,4217,4219],{},[80,4213,679],{},[80,4215,4216],{},"Différentiel groupe 30 mA",[80,4218,200],{},[80,4220,3007],{},[65,4222,4223,4225,4228,4230],{},[80,4224,213],{},[80,4226,4227],{},"Disj. B10A",[80,4229,187],{},[80,4231,4232],{},"Éclairage RDC",[65,4234,4235,4237,4239,4241],{},[80,4236,226],{},[80,4238,4227],{},[80,4240,187],{},[80,4242,4243],{},"Éclairage étage",[65,4245,4246,4248,4250,4252],{},[80,4247,797],{},[80,4249,4227],{},[80,4251,187],{},[80,4253,4254],{},"Éclairage cave\u002Fextérieur",[65,4256,4257,4259,4262,4264],{},[80,4258,809],{},[80,4260,4261],{},"Disj. B16A",[80,4263,187],{},[80,4265,4266],{},"Prises séjour",[65,4268,4269,4271,4273,4275],{},[80,4270,822],{},[80,4272,4261],{},[80,4274,187],{},[80,4276,4277],{},"Prises salle à manger",[65,4279,4280,4282,4284,4286],{},[80,4281,735],{},[80,4283,4261],{},[80,4285,187],{},[80,4287,4288],{},"Prises couloir",[65,4290,4291,4293,4295,4297],{},[80,4292,845],{},[80,4294,4184],{},[80,4296,850],{},[80,4298,4189],{},[27,4300,4302],{"id":4301},"rangée-3-groupe-2-cuisine-chambres-18-modules","Rangée 3 — Groupe 2 : Cuisine + chambres (18 modules)",[59,4304,4305,4317],{},[62,4306,4307],{},[65,4308,4309,4311,4313,4315],{},[68,4310,665],{},[68,4312,2350],{},[68,4314,4126],{},[68,4316,4129],{},[75,4318,4319,4329,4340,4352,4363,4374,4385,4396],{},[65,4320,4321,4323,4325,4327],{},[80,4322,679],{},[80,4324,4216],{},[80,4326,200],{},[80,4328,3007],{},[65,4330,4331,4333,4335,4337],{},[80,4332,213],{},[80,4334,4261],{},[80,4336,187],{},[80,4338,4339],{},"Prises cuisine",[65,4341,4342,4344,4347,4349],{},[80,4343,226],{},[80,4345,4346],{},"Disj. B20A",[80,4348,187],{},[80,4350,4351],{},"Four (dédié)",[65,4353,4354,4356,4358,4360],{},[80,4355,797],{},[80,4357,4261],{},[80,4359,187],{},[80,4361,4362],{},"Lave-vaisselle (dédié)",[65,4364,4365,4367,4369,4371],{},[80,4366,809],{},[80,4368,4261],{},[80,4370,187],{},[80,4372,4373],{},"Réfrigérateur (dédié)",[65,4375,4376,4378,4380,4382],{},[80,4377,822],{},[80,4379,4261],{},[80,4381,187],{},[80,4383,4384],{},"Prises chambre 1",[65,4386,4387,4389,4391,4393],{},[80,4388,735],{},[80,4390,4261],{},[80,4392,187],{},[80,4394,4395],{},"Prises chambres 2+3",[65,4397,4398,4400,4402,4404],{},[80,4399,845],{},[80,4401,4184],{},[80,4403,850],{},[80,4405,4189],{},[27,4407,4409],{"id":4408},"rangée-4-groupe-3-sdb-extérieur-technique-18-modules","Rangée 4 — Groupe 3 : SDB, extérieur, technique (18 modules)",[59,4411,4412,4424],{},[62,4413,4414],{},[65,4415,4416,4418,4420,4422],{},[68,4417,665],{},[68,4419,2350],{},[68,4421,4126],{},[68,4423,4129],{},[75,4425,4426,4436,4446,4457,4468,4479,4489,4499],{},[65,4427,4428,4430,4432,4434],{},[80,4429,679],{},[80,4431,4216],{},[80,4433,200],{},[80,4435,3007],{},[65,4437,4438,4440,4442,4444],{},[80,4439,213],{},[80,4441,4261],{},[80,4443,187],{},[80,4445,3822],{},[65,4447,4448,4450,4452,4454],{},[80,4449,226],{},[80,4451,4261],{},[80,4453,187],{},[80,4455,4456],{},"Lave-linge (dédié)",[65,4458,4459,4461,4463,4465],{},[80,4460,797],{},[80,4462,4261],{},[80,4464,187],{},[80,4466,4467],{},"Sèche-linge (dédié)",[65,4469,4470,4472,4474,4476],{},[80,4471,809],{},[80,4473,4346],{},[80,4475,187],{},[80,4477,4478],{},"Boiler (dédié)",[65,4480,4481,4483,4485,4487],{},[80,4482,822],{},[80,4484,4261],{},[80,4486,187],{},[80,4488,3831],{},[65,4490,4491,4493,4495,4497],{},[80,4492,735],{},[80,4494,4261],{},[80,4496,187],{},[80,4498,367],{},[65,4500,4501,4503,4505,4507],{},[80,4502,845],{},[80,4504,4184],{},[80,4506,850],{},[80,4508,4189],{},[15,4510,4511],{},[35,4512,4513],{},"Total : 24 disjoncteurs + 4 différentiels + parafoudre + interrupteur principal = env. 40 modules occupés sur 72 → 44 % de réserve",[19,4515],{},[22,4517,4519],{"id":4518},"erreurs-typiques-de-planification","Erreurs typiques de planification",[59,4521,4522,4534],{},[62,4523,4524],{},[65,4525,4526,4529,4532],{},[68,4527,4528],{},"Erreur",[68,4530,4531],{},"Conséquence",[68,4533,3318],{},[75,4535,4536,4547,4558,4569,4580,4591,4602],{},[65,4537,4538,4541,4544],{},[80,4539,4540],{},"Trop peu de rangées",[80,4542,4543],{},"Pas de place pour les extensions",[80,4545,4546],{},"Min. 4 rangées pour maison",[65,4548,4549,4552,4555],{},[80,4550,4551],{},"Pas de parafoudre",[80,4553,4554],{},"Recommandé selon les règles de l'art (Art. 4.5.1)",[80,4556,4557],{},"Prévoir parafoudre (SPD)",[65,4559,4560,4563,4566],{},[80,4561,4562],{},"Plus de 8 circuits terminaux par différentiel",[80,4564,4565],{},"Non-conformité RGIE (Art. 4.2.4.3b)",[80,4567,4568],{},"Ajouter un différentiel de groupe",[65,4570,4571,4574,4577],{},[80,4572,4573],{},"Étiquetage manquant",[80,4575,4576],{},"Remarque lors du contrôle",[80,4578,4579],{},"Étiqueter chaque disjoncteur (n° circuit + fonction)",[65,4581,4582,4585,4588],{},[80,4583,4584],{},"Pas de différentiel principal 300 mA",[80,4586,4587],{},"Sélectivité absente",[80,4589,4590],{},"Toujours prévoir un différentiel principal",[65,4592,4593,4596,4599],{},[80,4594,4595],{},"Mauvais type de différentiel pour borne de recharge",[80,4597,4598],{},"Déclenchement incorrect",[80,4600,4601],{},"Utiliser Type B ou Type A-EV",[65,4603,4604,4607,4610],{},[80,4605,4606],{},"Pas de réserve",[80,4608,4609],{},"Modification coûteuse",[80,4611,4612],{},"Min. 20 % d'emplacements libres",[19,4614],{},[22,4616,4618],{"id":4617},"étiquetage-et-documentation","Étiquetage et documentation",[15,4620,4621,4622,4625],{},"Chaque disjoncteur doit être ",[35,4623,4624],{},"étiqueté"," avec :",[615,4627,4628,4631,4634],{},[618,4629,4630],{},"Numéro de circuit (identique au schéma unifilaire et au plan de situation)",[618,4632,4633],{},"Fonction (par ex. « Éclairage RDC », « Prises cuisine »)",[618,4635,4636],{},"Optionnel : pièce ou étage",[15,4638,4639,4640,4643],{},"Collez l'étiquette ",[35,4641,4642],{},"dans le couvercle"," du tableau ou utilisez une bandelette d'identification. La plupart des fabricants de tableaux fournissent des inserts inscriptibles.",[19,4645],{},[22,4647,4649],{"id":4648},"articles-connexes","Articles connexes",[615,4651,4652,4658,4664,4670],{},[618,4653,4654],{},[1211,4655,4657],{"href":4656},"\u002Ffr\u002Fblog\u002Fquest-ce-quun-schema-unifilaire","Qu'est-ce qu'un schéma unifilaire ?",[618,4659,4660],{},[1211,4661,4663],{"href":4662},"\u002Ffr\u002Fblog\u002F30ma-rcd-par-prise","Différentiel 30 mA obligatoire par circuit prises",[618,4665,4666],{},[1211,4667,4669],{"href":4668},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","Section de câble et disjoncteur : la bonne combinaison",[618,4671,4672],{},[1211,4673,4675],{"href":4674},"\u002Ffr\u002Fblog\u002Fpanneaux-solaires-schema","Installation PV dans le schéma",[19,4677],{},[15,4679,4680],{},[1238,4681,4682,4683,4685,4686],{},"Planifiez votre tableau visuellement avec le ",[35,4684,1243],{}," — glissez les modules sur le rail DIN, vérification RGIE automatique incluse. ",[1211,4687,4688],{"href":1247},"Essayer maintenant →",{"title":435,"searchDepth":1250,"depth":1250,"links":4690},[4691,4696,4697,4702,4706,4707,4713,4714,4715],{"id":3530,"depth":1250,"text":3531,"children":4692},[4693,4694,4695],{"id":3534,"depth":1255,"text":3535},{"id":3549,"depth":1255,"text":3550},{"id":3651,"depth":1255,"text":3652},{"id":3731,"depth":1250,"text":3732},{"id":3890,"depth":1250,"text":3891,"children":4698},[4699,4700,4701],{"id":3901,"depth":1255,"text":3902},{"id":3911,"depth":1255,"text":3912},{"id":3978,"depth":1255,"text":3979},{"id":3990,"depth":1250,"text":3991,"children":4703},[4704,4705],{"id":3994,"depth":1255,"text":3995},{"id":4005,"depth":1255,"text":4006},{"id":4065,"depth":1250,"text":4066},{"id":4105,"depth":1250,"text":4106,"children":4708},[4709,4710,4711,4712],{"id":4112,"depth":1255,"text":4113},{"id":4192,"depth":1255,"text":4193},{"id":4301,"depth":1255,"text":4302},{"id":4408,"depth":1255,"text":4409},{"id":4518,"depth":1250,"text":4519},{"id":4617,"depth":1250,"text":4618},{"id":4648,"depth":1250,"text":4649},"Guide complet pour la planification d'un tableau de distribution. Rail DIN, dispositifs de protection, répartition en rangées et exemple pour une maison unifamiliale.","fr",{},"\u002Fblog\u002Fdistribution-board-planning.fr",{"title":3517,"description":4716},"planifier-tableau-electrique","blog\u002Fdistribution-board-planning.fr",[4724,4725,4726,1295,263,4727,4728,4729],"tableau électrique","distribution","rail DIN","RGIE","planification","maison unifamiliale","-qxvao9UQ2a4ocD3Rb_BYaODl2pZludEyiv6VpVA8pU",{"id":4732,"title":4733,"articleId":6,"body":4734,"category":1278,"date":1279,"description":5921,"extension":1281,"lastUpdated":1279,"locale":5922,"meta":5923,"navigation":1284,"path":5924,"publishDate":1279,"readTime":1286,"refreshInterval":1287,"seo":5925,"slug":5926,"stem":5927,"tags":5928,"__hash__":5933},"blog\u002Fblog\u002Fdistribution-board-planning.nl.md","Verdeelkast plannen: Opbouw en dimensionering volgens AREI",{"type":8,"value":4735,"toc":5894},[4736,4739,4742,4744,4748,4751,4762,4766,4775,4853,4857,4860,4924,4931,4933,4937,4940,5082,5093,5095,5099,5106,5110,5116,5119,5183,5187,5193,5195,5199,5203,5210,5214,5268,5270,5274,5281,5293,5298,5309,5311,5315,5318,5322,5396,5400,5503,5507,5609,5613,5713,5718,5720,5724,5818,5820,5824,5831,5842,5849,5851,5855,5881,5883],[11,4737,4733],{"id":4738},"verdeelkast-plannen-opbouw-en-dimensionering-volgens-arei",[15,4740,4741],{},"De verdeelkast (ook zekeringskast of verdeelbord) is het hart van elke elektrische installatie. Hier komen alle kringen samen, hier zitten de beveiligingstoestellen die uw woning en gezin beschermen tegen elektrische gevaren. Een doordachte planning bespaart niet alleen geld, maar voorkomt ook problemen bij de AREI-keuring.",[19,4743],{},[22,4745,4747],{"id":4746},"basisprincipes-opbouw-van-een-verdeelkast","Basisprincipes: Opbouw van een verdeelkast",[27,4749,4750],{"id":2316},"DIN-rail (Omega-rail)",[15,4752,4753,4754,4757,4758,4761],{},"Alle modules in de verdeler worden op gestandaardiseerde ",[35,4755,4756],{},"DIN-rails"," (35 mm omega-rail volgens EN 60715) geklikt. Elke rail vormt een ",[35,4759,4760],{},"rij"," in de verdeler.",[27,4763,4765],{"id":4764},"te-eenheden-delingseenheden","TE-eenheden (delingseenheden)",[15,4767,4768,4769,4771,4772,4774],{},"De breedte van een module wordt gemeten in ",[35,4770,52],{}," (delingseenheden). Eén TE komt overeen met ",[35,4773,56],{},". Typische breedtes:",[59,4776,4777,4786],{},[62,4778,4779],{},[65,4780,4781,4783],{},[68,4782,2350],{},[68,4784,4785],{},"Breedte (TE)",[75,4787,4788,4794,4800,4806,4812,4818,4825,4832,4839,4846],{},[65,4789,4790,4792],{},[80,4791,82],{},[80,4793,85],{},[65,4795,4796,4798],{},[80,4797,90],{},[80,4799,93],{},[65,4801,4802,4804],{},[80,4803,98],{},[80,4805,101],{},[65,4807,4808,4810],{},[80,4809,106],{},[80,4811,93],{},[65,4813,4814,4816],{},[80,4815,113],{},[80,4817,116],{},[65,4819,4820,4823],{},[80,4821,4822],{},"Hoofdschakelaar 2-polig",[80,4824,93],{},[65,4826,4827,4830],{},[80,4828,4829],{},"Hoofdschakelaar 4-polig",[80,4831,116],{},[65,4833,4834,4837],{},[80,4835,4836],{},"SPD (overspanningsbeveiliging)",[80,4838,138],{},[65,4840,4841,4844],{},[80,4842,4843],{},"Beltransformator",[80,4845,93],{},[65,4847,4848,4851],{},[80,4849,4850],{},"Tijdschakelaar",[80,4852,93],{},[27,4854,4856],{"id":4855},"verdeelkastafmetingen","Verdeelkastafmetingen",[15,4858,4859],{},"Verdeelkasten worden gedimensioneerd op basis van rijen en TE per rij:",[59,4861,4862,4878],{},[62,4863,4864],{},[65,4865,4866,4869,4872,4875],{},[68,4867,4868],{},"Aanduiding",[68,4870,4871],{},"Rijen",[68,4873,4874],{},"TE per rij",[68,4876,4877],{},"Totaal TE",[75,4879,4880,4891,4902,4913],{},[65,4881,4882,4885,4887,4889],{},[80,4883,4884],{},"1-rijig",[80,4886,187],{},[80,4888,190],{},[80,4890,190],{},[65,4892,4893,4896,4898,4900],{},[80,4894,4895],{},"2-rijig",[80,4897,200],{},[80,4899,190],{},[80,4901,205],{},[65,4903,4904,4907,4909,4911],{},[80,4905,4906],{},"3-rijig",[80,4908,213],{},[80,4910,190],{},[80,4912,218],{},[65,4914,4915,4918,4920,4922],{},[80,4916,4917],{},"4-rijig",[80,4919,226],{},[80,4921,190],{},[80,4923,231],{},[233,4925,4926],{},[15,4927,4928],{},[35,4929,4930],{},"Voor een typische eengezinswoning raden we minstens een 4-rijige verdeler aan met 18 TE per rij (72 TE totaal).",[19,4932],{},[22,4934,4936],{"id":4935},"stap-1-kringen-tellen","Stap 1: Kringen tellen",[15,4938,4939],{},"Maak een lijst van alle benodigde kringen. Voor een gemiddelde eengezinswoning (3 slaapkamers, 150 m²) rekent u op:",[59,4941,4942,4953],{},[62,4943,4944],{},[65,4945,4946,4948,4951],{},[68,4947,2521],{},[68,4949,4950],{},"Aantal",[68,4952,263],{},[75,4954,4955,4966,4976,4986,4996,5005,5014,5023,5032,5041,5051,5059,5068],{},[65,4956,4957,4960,4963],{},[80,4958,4959],{},"Verlichting",[80,4961,4962],{},"3–4 kringen",[80,4964,4965],{},"B10A of B16A",[65,4967,4968,4971,4974],{},[80,4969,4970],{},"Stopcontacten algemeen",[80,4972,4973],{},"4–6 kringen",[80,4975,287],{},[65,4977,4978,4981,4983],{},[80,4979,4980],{},"Keuken apart (oven)",[80,4982,187],{},[80,4984,4985],{},"B20A of B32A",[65,4987,4988,4991,4993],{},[80,4989,4990],{},"Keuken apart (kookplaat)",[80,4992,187],{},[80,4994,4995],{},"B32A (evt. 3-fasig)",[65,4997,4998,5001,5003],{},[80,4999,5000],{},"Keuken apart (vaatwasser)",[80,5002,187],{},[80,5004,287],{},[65,5006,5007,5010,5012],{},[80,5008,5009],{},"Wasmachine",[80,5011,187],{},[80,5013,287],{},[65,5015,5016,5019,5021],{},[80,5017,5018],{},"Droogkast",[80,5020,187],{},[80,5022,287],{},[65,5024,5025,5028,5030],{},[80,5026,5027],{},"Badkamer stopcontacten",[80,5029,187],{},[80,5031,287],{},[65,5033,5034,5037,5039],{},[80,5035,5036],{},"Buiten stopcontacten",[80,5038,187],{},[80,5040,287],{},[65,5042,5043,5046,5048],{},[80,5044,5045],{},"Boiler \u002F warm water",[80,5047,187],{},[80,5049,5050],{},"B16A of B20A",[65,5052,5053,5055,5057],{},[80,5054,367],{},[80,5056,187],{},[80,5058,287],{},[65,5060,5061,5064,5066],{},[80,5062,5063],{},"Laadpaal (indien aanwezig)",[80,5065,187],{},[80,5067,381],{},[65,5069,5070,5075,5080],{},[80,5071,5072],{},[35,5073,5074],{},"Totaal",[80,5076,5077],{},[35,5078,5079],{},"17–21 kringen",[80,5081],{},[233,5083,5084],{},[15,5085,5086,5088,5089,5092],{},[35,5087,2662],{}," Maximaal ",[35,5090,5091],{},"8 stopcontacten"," per kring (AREI Art. 5.3.5.2b). Lichtkringen mogen meer punten hebben, maar in de praktijk worden max. 8 lichtpunten per kring aanbevolen.",[19,5094],{},[22,5096,5098],{"id":5097},"stap-2-beveiligingstoestellen-kiezen","Stap 2: Beveiligingstoestellen kiezen",[15,5100,5101,5102,5105],{},"De beveiligingstoestellen worden ",[35,5103,5104],{},"hiërarchisch"," gerangschikt — van de voeding (bovenaan) naar beneden:",[27,5107,5109],{"id":5108},"hiërarchie-van-beveiligingstoestellen","Hiërarchie van beveiligingstoestellen",[426,5111,5114],{"className":5112,"code":5113,"language":431},[429],"Hoofdschakelaar (40A of 63A)\n   └── Hoofd-RCD 300 mA (Type A-S, selectief)\n        ├── Groeps-RCD 30 mA #1 (Type A)\n        │    ├── MCB Licht gelijkvloers (B10A)\n        │    ├── MCB Licht verdieping (B10A)\n        │    ├── MCB Stopcontacten woonkamer (B16A)\n        │    └── MCB Stopcontacten gang (B16A)\n        ├── Groeps-RCD 30 mA #2 (Type A)\n        │    ├── MCB Stopcontacten keuken (B16A)\n        │    ├── MCB Oven (B20A)\n        │    ├── MCB Vaatwasser (B16A)\n        │    └── MCB Stopcontacten slaapkamer (B16A)\n        └── Groeps-RCD 30 mA #3 (Type A)\n             ├── MCB Wasmachine (B16A)\n             ├── MCB Badkamer (B16A)\n             ├── MCB Buiten (B16A)\n             └── MCB Garage (B16A)\n",[433,5115,5113],{"__ignoreMap":435},[27,5117,5118],{"id":2693},"RCD-types",[59,5120,5121,5133],{},[62,5122,5123],{},[65,5124,5125,5127,5130],{},[68,5126,2521],{},[68,5128,5129],{},"Uitschakelstroom",[68,5131,5132],{},"Toepassing",[75,5134,5135,5147,5159,5171],{},[65,5136,5137,5141,5144],{},[80,5138,5139],{},[35,5140,2717],{},[80,5142,5143],{},"300 mA, selectief (vertraagd)",[80,5145,5146],{},"Hoofd-RCD, schakelt alleen bij fout achter groeps-RCDs",[65,5148,5149,5153,5156],{},[80,5150,5151],{},[35,5152,2730],{},[80,5154,5155],{},"30 mA, onvertraagd",[80,5157,5158],{},"Groeps-RCD, persoonsbescherming",[65,5160,5161,5165,5168],{},[80,5162,5163],{},[35,5164,2743],{},[80,5166,5167],{},"30 mA, alle stroomsoorten",[80,5169,5170],{},"Voor laadpaal \u002F omvormer met DC-component",[65,5172,5173,5177,5180],{},[80,5174,5175],{},[35,5176,2756],{},[80,5178,5179],{},"30 mA, frequentie-onafhankelijk",[80,5181,5182],{},"Voor frequentie-omvormers (warmtepomp)",[27,5184,5186],{"id":5185},"selectiviteit","Selectiviteit",[15,5188,5189,5190,5192],{},"De hoofd-RCD (300 mA, ",[35,5191,2772],{}," = selectief) is vertraagd en schakelt pas uit wanneer de groeps-RCD (30 mA) niet heeft gereageerd. Zo valt bij een fout alleen de betreffende groeps-RCD, niet de hele installatie.",[19,5194],{},[22,5196,5198],{"id":5197},"stap-3-verdeling-over-rijen","Stap 3: Verdeling over rijen",[27,5200,5202],{"id":5201},"arei-regel-max-8-eindkringen-per-rcd","AREI-regel: Max. 8 eindkringen per RCD",[15,5204,5205,5206,5209],{},"Volgens AREI Art. 4.2.4.3b mogen maximaal ",[35,5207,5208],{},"8 eindkringen"," achter één aardlekschakelaar (RCD) worden aangesloten. In de praktijk worden 4–6 MCBs per RCD aanbevolen voor een comfortabele reserve.",[27,5211,5213],{"id":5212},"typische-rijverdeling","Typische rijverdeling",[59,5215,5216,5226],{},[62,5217,5218],{},[65,5219,5220,5223],{},[68,5221,5222],{},"Rij",[68,5224,5225],{},"Inhoud",[75,5227,5228,5238,5248,5258],{},[65,5229,5230,5235],{},[80,5231,5232],{},[35,5233,5234],{},"Rij 1",[80,5236,5237],{},"Hoofdschakelaar, Hoofd-RCD (300 mA), SPD, evt. beltransformator",[65,5239,5240,5245],{},[80,5241,5242],{},[35,5243,5244],{},"Rij 2",[80,5246,5247],{},"Groeps-RCD #1 (30 mA) + bijbehorende MCBs (licht + stopcontacten woonzone)",[65,5249,5250,5255],{},[80,5251,5252],{},[35,5253,5254],{},"Rij 3",[80,5256,5257],{},"Groeps-RCD #2 (30 mA) + bijbehorende MCBs (keuken + slaapkamers)",[65,5259,5260,5265],{},[80,5261,5262],{},[35,5263,5264],{},"Rij 4",[80,5266,5267],{},"Groeps-RCD #3 (30 mA) + bijbehorende MCBs (badkamer, buiten, garage, technisch)",[19,5269],{},[22,5271,5273],{"id":5272},"stap-4-reserveplaatsen-inplannen","Stap 4: Reserveplaatsen inplannen",[15,5275,5276,5277,5280],{},"Plan minstens ",[35,5278,5279],{},"20% reserveplaatsen"," in — liever 30%. Dit betekent:",[615,5282,5283,5286],{},[618,5284,5285],{},"Bij 20 benodigde MCBs → minstens 4–6 vrije TE-plaatsen.",[618,5287,5288,5289,5292],{},"Lege plaatsen worden met ",[35,5290,5291],{},"blindplaten"," afgesloten.",[15,5294,5295],{},[35,5296,5297],{},"Waarom?",[615,5299,5300,5303,5306],{},[618,5301,5302],{},"Toekomstige uitbreidingen (laadpaal, airco, sauna).",[618,5304,5305],{},"Herverdeling als een RCD te veel kringen heeft.",[618,5307,5308],{},"Vermijding van een dure kast-vervanging.",[19,5310],{},[22,5312,5314],{"id":5313},"voorbeeldopstelling-4-rijige-verdeler-voor-eengezinswoning","Voorbeeldopstelling: 4-rijige verdeler voor eengezinswoning",[15,5316,5317],{},"Hier een compleet voorbeeld voor een typische Belgische eengezinswoning (3 SK, 150 m², zonder PV):",[27,5319,5321],{"id":5320},"rij-1-voeding-bescherming-18-te","Rij 1 — Voeding & bescherming (18 TE)",[59,5323,5324,5338],{},[62,5325,5326],{},[65,5327,5328,5331,5333,5335],{},[68,5329,5330],{},"Positie",[68,5332,2350],{},[68,5334,52],{},[68,5336,5337],{},"Functie",[75,5339,5340,5352,5363,5374,5385],{},[65,5341,5342,5344,5347,5349],{},[80,5343,679],{},[80,5345,5346],{},"Hoofdschakelaar 2P",[80,5348,200],{},[80,5350,5351],{},"40A hoofdschakelaar",[65,5353,5354,5356,5359,5361],{},[80,5355,692],{},[80,5357,5358],{},"Hoofd-RCD 2P",[80,5360,200],{},[80,5362,2717],{},[65,5364,5365,5367,5369,5371],{},[80,5366,704],{},[80,5368,707],{},[80,5370,226],{},[80,5372,5373],{},"Overspanningsbeveiliging",[65,5375,5376,5378,5380,5382],{},[80,5377,717],{},[80,5379,4843],{},[80,5381,200],{},[80,5383,5384],{},"8V deurbel",[65,5386,5387,5389,5391,5393],{},[80,5388,729],{},[80,5390,732],{},[80,5392,735],{},[80,5394,5395],{},"Blindplaten",[27,5397,5399],{"id":5398},"rij-2-groep-1-verlichting-woonzone-18-te","Rij 2 — Groep 1: Verlichting + woonzone (18 TE)",[59,5401,5402,5414],{},[62,5403,5404],{},[65,5405,5406,5408,5410,5412],{},[68,5407,5330],{},[68,5409,2350],{},[68,5411,52],{},[68,5413,5337],{},[75,5415,5416,5427,5438,5449,5460,5471,5482,5493],{},[65,5417,5418,5420,5423,5425],{},[80,5419,679],{},[80,5421,5422],{},"Groeps-RCD 30 mA",[80,5424,200],{},[80,5426,3007],{},[65,5428,5429,5431,5433,5435],{},[80,5430,213],{},[80,5432,776],{},[80,5434,187],{},[80,5436,5437],{},"Licht gelijkvloers",[65,5439,5440,5442,5444,5446],{},[80,5441,226],{},[80,5443,776],{},[80,5445,187],{},[80,5447,5448],{},"Licht verdieping",[65,5450,5451,5453,5455,5457],{},[80,5452,797],{},[80,5454,776],{},[80,5456,187],{},[80,5458,5459],{},"Licht kelder\u002Fbuiten",[65,5461,5462,5464,5466,5468],{},[80,5463,809],{},[80,5465,812],{},[80,5467,187],{},[80,5469,5470],{},"Stopcontacten woonkamer",[65,5472,5473,5475,5477,5479],{},[80,5474,822],{},[80,5476,812],{},[80,5478,187],{},[80,5480,5481],{},"Stopcontacten eetkamer",[65,5483,5484,5486,5488,5490],{},[80,5485,735],{},[80,5487,812],{},[80,5489,187],{},[80,5491,5492],{},"Stopcontacten gang",[65,5494,5495,5497,5499,5501],{},[80,5496,845],{},[80,5498,732],{},[80,5500,850],{},[80,5502,5395],{},[27,5504,5506],{"id":5505},"rij-3-groep-2-keuken-slaapkamers-18-te","Rij 3 — Groep 2: Keuken + slaapkamers (18 TE)",[59,5508,5509,5521],{},[62,5510,5511],{},[65,5512,5513,5515,5517,5519],{},[68,5514,5330],{},[68,5516,2350],{},[68,5518,52],{},[68,5520,5337],{},[75,5522,5523,5533,5544,5555,5566,5577,5588,5599],{},[65,5524,5525,5527,5529,5531],{},[80,5526,679],{},[80,5528,5422],{},[80,5530,200],{},[80,5532,3007],{},[65,5534,5535,5537,5539,5541],{},[80,5536,213],{},[80,5538,812],{},[80,5540,187],{},[80,5542,5543],{},"Stopcontacten keuken",[65,5545,5546,5548,5550,5552],{},[80,5547,226],{},[80,5549,900],{},[80,5551,187],{},[80,5553,5554],{},"Oven (apart)",[65,5556,5557,5559,5561,5563],{},[80,5558,797],{},[80,5560,812],{},[80,5562,187],{},[80,5564,5565],{},"Vaatwasser (apart)",[65,5567,5568,5570,5572,5574],{},[80,5569,809],{},[80,5571,812],{},[80,5573,187],{},[80,5575,5576],{},"Koelkast (apart)",[65,5578,5579,5581,5583,5585],{},[80,5580,822],{},[80,5582,812],{},[80,5584,187],{},[80,5586,5587],{},"Stopcontacten slaapkamer 1",[65,5589,5590,5592,5594,5596],{},[80,5591,735],{},[80,5593,812],{},[80,5595,187],{},[80,5597,5598],{},"Stopcontacten slaapkamer 2+3",[65,5600,5601,5603,5605,5607],{},[80,5602,845],{},[80,5604,732],{},[80,5606,850],{},[80,5608,5395],{},[27,5610,5612],{"id":5611},"rij-4-groep-3-badkamer-buiten-technisch-18-te","Rij 4 — Groep 3: Badkamer, buiten, technisch (18 TE)",[59,5614,5615,5627],{},[62,5616,5617],{},[65,5618,5619,5621,5623,5625],{},[68,5620,5330],{},[68,5622,2350],{},[68,5624,52],{},[68,5626,5337],{},[75,5628,5629,5639,5650,5661,5672,5683,5693,5703],{},[65,5630,5631,5633,5635,5637],{},[80,5632,679],{},[80,5634,5422],{},[80,5636,200],{},[80,5638,3007],{},[65,5640,5641,5643,5645,5647],{},[80,5642,213],{},[80,5644,812],{},[80,5646,187],{},[80,5648,5649],{},"Stopcontacten badkamer",[65,5651,5652,5654,5656,5658],{},[80,5653,226],{},[80,5655,812],{},[80,5657,187],{},[80,5659,5660],{},"Wasmachine (apart)",[65,5662,5663,5665,5667,5669],{},[80,5664,797],{},[80,5666,812],{},[80,5668,187],{},[80,5670,5671],{},"Droogkast (apart)",[65,5673,5674,5676,5678,5680],{},[80,5675,809],{},[80,5677,900],{},[80,5679,187],{},[80,5681,5682],{},"Boiler (apart)",[65,5684,5685,5687,5689,5691],{},[80,5686,822],{},[80,5688,812],{},[80,5690,187],{},[80,5692,5036],{},[65,5694,5695,5697,5699,5701],{},[80,5696,735],{},[80,5698,812],{},[80,5700,187],{},[80,5702,367],{},[65,5704,5705,5707,5709,5711],{},[80,5706,845],{},[80,5708,732],{},[80,5710,850],{},[80,5712,5395],{},[15,5714,5715],{},[35,5716,5717],{},"Totaal: 24 MCBs + 4 RCDs + SPD + hoofdschakelaar = ca. 40 TE bezet van 72 TE → 44% reserve",[19,5719],{},[22,5721,5723],{"id":5722},"typische-fouten-bij-verdeelkastplanning","Typische fouten bij verdeelkastplanning",[59,5725,5726,5739],{},[62,5727,5728],{},[65,5729,5730,5733,5736],{},[68,5731,5732],{},"Fout",[68,5734,5735],{},"Gevolg",[68,5737,5738],{},"Oplossing",[75,5740,5741,5752,5763,5774,5785,5796,5807],{},[65,5742,5743,5746,5749],{},[80,5744,5745],{},"Te weinig rijen",[80,5747,5748],{},"Geen ruimte voor uitbreidingen",[80,5750,5751],{},"Min. 4 rijen voor EGW",[65,5753,5754,5757,5760],{},[80,5755,5756],{},"Geen SPD (overspanningsbeveiliging)",[80,5758,5759],{},"Aanbevolen volgens de regels van het vak (Art. 4.5.1)",[80,5761,5762],{},"SPD voorzien",[65,5764,5765,5768,5771],{},[80,5766,5767],{},"Meer dan 8 eindkringen per RCD",[80,5769,5770],{},"AREI-overtreding (Art. 4.2.4.3b)",[80,5772,5773],{},"Extra groeps-RCD plaatsen",[65,5775,5776,5779,5782],{},[80,5777,5778],{},"Ontbrekende opschriften",[80,5780,5781],{},"Opmerking bij keuring",[80,5783,5784],{},"Elke MCB labelen (kringnummer + functie)",[65,5786,5787,5790,5793],{},[80,5788,5789],{},"Geen hoofd-RCD 300 mA",[80,5791,5792],{},"Ontbrekende selectiviteit",[80,5794,5795],{},"Altijd hoofd-RCD voorzien",[65,5797,5798,5801,5804],{},[80,5799,5800],{},"Verkeerd RCD-type voor laadpaal",[80,5802,5803],{},"Foutieve uitschakeling",[80,5805,5806],{},"Type B of Type A-EV gebruiken",[65,5808,5809,5812,5815],{},[80,5810,5811],{},"Geen reserve",[80,5813,5814],{},"Dure aanpassing achteraf",[80,5816,5817],{},"Min. 20% vrije plaatsen",[19,5819],{},[22,5821,5823],{"id":5822},"opschriften-en-documentatie","Opschriften en documentatie",[15,5825,5826,5827,5830],{},"Elke MCB moet ",[35,5828,5829],{},"gelabeld"," worden met:",[615,5832,5833,5836,5839],{},[618,5834,5835],{},"Kringnummer (identiek aan éénlijnschema en situatieschema)",[618,5837,5838],{},"Functie (bijv. \"Licht GV\", \"Stopcontacten keuken\")",[618,5840,5841],{},"Optioneel: ruimte of verdieping",[15,5843,5844,5845,5848],{},"Plak het opschrift ",[35,5846,5847],{},"in het deksel"," van de verdeler of gebruik een opschriftstrip. De meeste verdelerfabrikanten leveren beschrijfbare inlegstrookjes mee.",[19,5850],{},[22,5852,5854],{"id":5853},"gerelateerde-artikelen","Gerelateerde artikelen",[615,5856,5857,5863,5869,5875],{},[618,5858,5859],{},[1211,5860,5862],{"href":5861},"\u002Fblog\u002Fwat-is-eenlijnschema","Wat is een éénlijnschema?",[618,5864,5865],{},[1211,5866,5868],{"href":5867},"\u002Fblog\u002F30ma-rcd-per-stopcontact","30 mA RCD verplicht per stopcontactkring",[618,5870,5871],{},[1211,5872,5874],{"href":5873},"\u002Fblog\u002Fkabeldoorsnede-automaat","Kabeldoorsnede en automaat: De juiste combinatie",[618,5876,5877],{},[1211,5878,5880],{"href":5879},"\u002Fblog\u002Fzonnepanelen-schema","Zonnepanelen in het schema",[19,5882],{},[15,5884,5885],{},[1238,5886,5887,5888,5890,5891],{},"Plan uw verdeelkast visueel met de ",[35,5889,1243],{}," — modules slepen op de DIN-rail, automatische AREI-controle inbegrepen. ",[1211,5892,5893],{"href":1247},"Nu uitproberen →",{"title":435,"searchDepth":1250,"depth":1250,"links":5895},[5896,5901,5902,5907,5911,5912,5918,5919,5920],{"id":4746,"depth":1250,"text":4747,"children":5897},[5898,5899,5900],{"id":2316,"depth":1255,"text":4750},{"id":4764,"depth":1255,"text":4765},{"id":4855,"depth":1255,"text":4856},{"id":4935,"depth":1250,"text":4936},{"id":5097,"depth":1250,"text":5098,"children":5903},[5904,5905,5906],{"id":5108,"depth":1255,"text":5109},{"id":2693,"depth":1255,"text":5118},{"id":5185,"depth":1255,"text":5186},{"id":5197,"depth":1250,"text":5198,"children":5908},[5909,5910],{"id":5201,"depth":1255,"text":5202},{"id":5212,"depth":1255,"text":5213},{"id":5272,"depth":1250,"text":5273},{"id":5313,"depth":1250,"text":5314,"children":5913},[5914,5915,5916,5917],{"id":5320,"depth":1255,"text":5321},{"id":5398,"depth":1255,"text":5399},{"id":5505,"depth":1255,"text":5506},{"id":5611,"depth":1255,"text":5612},{"id":5722,"depth":1250,"text":5723},{"id":5822,"depth":1250,"text":5823},{"id":5853,"depth":1250,"text":5854},"Volledige handleiding voor het plannen van een verdeelkast. DIN-rail, beveiligingstoestellen, rijverdeling en voorbeeldopstelling voor een eengezinswoning.","nl",{},"\u002Fblog\u002Fdistribution-board-planning.nl",{"title":4733,"description":5921},"verdeelkast-plannen-opbouw","blog\u002Fdistribution-board-planning.nl",[5929,5930,5931,1295,263,1296,3512,5932],"verdeelkast","verdeler","DIN-rail","eengezinswoning","pWDktORzwi5IxPcHmLDNiQZfzeFm6k57tAJDnb1jNB8",1779375815099]