[{"data":1,"prerenderedAt":4107},["ShallowReactive",2],{"blog-post-de-situationsplan-zeichnen-anleitung":3,"blog-alternates-draw-situation-plan":914},{"id":4,"title":5,"articleId":6,"body":7,"category":893,"date":894,"description":895,"extension":896,"lastUpdated":894,"locale":897,"meta":898,"navigation":772,"path":899,"publishDate":894,"readTime":900,"refreshInterval":901,"seo":902,"slug":903,"stem":904,"tags":905,"__hash__":913},"blog\u002Fblog\u002Fdraw-situation-plan.de.md","Situationsplan zeichnen: Schritt-für-Schritt-Anleitung nach AREI","draw-situation-plan",{"type":8,"value":9,"toc":871},"minimark",[10,14,23,41,44,47,52,57,60,65,90,94,97,207,209,213,224,403,411,413,417,420,424,455,459,479,483,503,506,509,533,537,557,559,563,570,575,587,592,606,623,625,629,632,658,660,664,755,757,761,829,831,835,856,858],[11,12,5],"h1",{"id":13},"situationsplan-zeichnen-schritt-für-schritt-anleitung-nach-arei",[15,16,17,18,22],"p",{},"Der Situationsplan (auch Lageplan oder Plan de Situation) zeigt, ",[19,20,21],"strong",{},"wo genau"," sich jede elektrische Komponente in Ihrem Gebäude befindet. Zusammen mit dem Eindrahtschema ist er eines der beiden Pflichtdokumente für jede Elektroinstallation in Belgien — ohne ihn besteht die Abnahme durch den zugelassenen Kontrollorganismus nicht.",[24,25,26],"blockquote",{},[15,27,28,31,32,36,37,40],{},[19,29,30],{},"Kurz erklärt:"," Während das Eindrahtschema die ",[33,34,35],"em",{},"logische Verschaltung"," darstellt (welcher Schalter steuert welche Leuchte, über welchen Stromkreis), zeigt der Situationsplan die ",[33,38,39],{},"physische Position"," jeder Komponente im Grundriss.",[15,42,43],{},"In dieser Anleitung lernen Sie, wie Sie einen normgerechten Situationsplan Schritt für Schritt erstellen.",[45,46],"hr",{},[48,49,51],"h2",{"id":50},"schritt-1-grundriss-vorbereiten","Schritt 1: Grundriss vorbereiten",[53,54,56],"h3",{"id":55},"maße-und-maßstab","Maße und Maßstab",[15,58,59],{},"Der Grundriss bildet die Basis Ihres Situationsplans. Sie können ihn aus einem Bauplan übernehmen oder selbst zeichnen.",[15,61,62],{},[19,63,64],{},"Wichtig:",[66,67,68,76,83],"ul",{},[69,70,71,72,75],"li",{},"Verwenden Sie einen ",[19,73,74],{},"einheitlichen Maßstab"," (üblich: 1:50 oder 1:100).",[69,77,78,79,82],{},"Zeichnen Sie alle ",[19,80,81],{},"Wände, Türen und Fenster"," ein.",[69,84,85,86,89],{},"Markieren Sie ",[19,87,88],{},"Öffnungsrichtungen"," von Türen (Viertelkreis) — das beeinflusst die Schalterposition.",[53,91,93],{"id":92},"räume-beschriften","Räume beschriften",[15,95,96],{},"Versehen Sie jeden Raum mit seiner Bezeichnung und idealerweise der Fläche:",[98,99,100,116],"table",{},[101,102,103],"thead",{},[104,105,106,110,113],"tr",{},[107,108,109],"th",{},"Kürzel",[107,111,112],{},"Raum",[107,114,115],{},"Typische Fläche",[117,118,119,131,142,153,164,175,186,197],"tbody",{},[104,120,121,125,128],{},[122,123,124],"td",{},"WZ",[122,126,127],{},"Wohnzimmer",[122,129,130],{},"25–40 m²",[104,132,133,136,139],{},[122,134,135],{},"KÜ",[122,137,138],{},"Küche",[122,140,141],{},"10–20 m²",[104,143,144,147,150],{},[122,145,146],{},"SZ",[122,148,149],{},"Schlafzimmer",[122,151,152],{},"12–18 m²",[104,154,155,158,161],{},[122,156,157],{},"BZ",[122,159,160],{},"Badezimmer",[122,162,163],{},"5–10 m²",[104,165,166,169,172],{},[122,167,168],{},"FL",[122,170,171],{},"Flur",[122,173,174],{},"5–15 m²",[104,176,177,180,183],{},[122,178,179],{},"GA",[122,181,182],{},"Garage",[122,184,185],{},"15–30 m²",[104,187,188,191,194],{},[122,189,190],{},"KE",[122,192,193],{},"Keller",[122,195,196],{},"variabel",[104,198,199,202,205],{},[122,200,201],{},"AU",[122,203,204],{},"Außenbereich",[122,206,196],{},[45,208],{},[48,210,212],{"id":211},"schritt-2-arei-symbole-verwenden","Schritt 2: AREI-Symbole verwenden",[15,214,215,216,219,220,223],{},"Das AREI schreibt in ",[19,217,218],{},"Tabelle 2.23"," genau vor, welche Symbole verwendet werden müssen. Diese basieren auf der Norm ",[19,221,222],{},"IEC 60617",". Hier die 10 wichtigsten Symbole für den Situationsplan:",[98,225,226,242],{},[101,227,228],{},[104,229,230,233,236,239],{},[107,231,232],{},"Nr.",[107,234,235],{},"Symbol",[107,237,238],{},"Beschreibung",[107,240,241],{},"Verwendung",[117,243,244,260,275,291,307,323,339,355,371,387],{},[104,245,246,249,252,257],{},[122,247,248],{},"1",[122,250,251],{},"⏚ Halbkreis",[122,253,254],{},[19,255,256],{},"Einfache Steckdose",[122,258,259],{},"Wandposition markieren",[104,261,262,265,268,273],{},[122,263,264],{},"2",[122,266,267],{},"⏚⏚ Doppel-Halbkreis",[122,269,270],{},[19,271,272],{},"Doppelsteckdose",[122,274,259],{},[104,276,277,280,283,288],{},[122,278,279],{},"3",[122,281,282],{},"○ mit Kreuz",[122,284,285],{},[19,286,287],{},"Deckenleuchte",[122,289,290],{},"Mitte des Raums\u002FPosition",[104,292,293,296,299,304],{},[122,294,295],{},"4",[122,297,298],{},"─○ mit Strich",[122,300,301],{},[19,302,303],{},"Wandleuchte",[122,305,306],{},"An der Wand",[104,308,309,312,315,320],{},[122,310,311],{},"5",[122,313,314],{},"Schaltzeichen",[122,316,317],{},[19,318,319],{},"Einfacher Schalter",[122,321,322],{},"Neben der Tür (Öffnungsseite)",[104,324,325,328,331,336],{},[122,326,327],{},"6",[122,329,330],{},"Schaltzeichen mit 2 Pfeilen",[122,332,333],{},[19,334,335],{},"Serienschalter",[122,337,338],{},"Steuert 2 Leuchten",[104,340,341,344,347,352],{},[122,342,343],{},"7",[122,345,346],{},"Schaltzeichen mit Linie",[122,348,349],{},[19,350,351],{},"Wechselschalter",[122,353,354],{},"Zwei Stellen, ein Licht",[104,356,357,360,363,368],{},[122,358,359],{},"8",[122,361,362],{},"Rechteck mit Blitz",[122,364,365],{},[19,366,367],{},"Verteilerkasten",[122,369,370],{},"Meist Flur\u002FTechnikraum",[104,372,373,376,379,384],{},[122,374,375],{},"9",[122,377,378],{},"⏚ mit PE",[122,380,381],{},[19,382,383],{},"Erdungsanschluss",[122,385,386],{},"Erdungspunkt",[104,388,389,392,395,400],{},[122,390,391],{},"10",[122,393,394],{},"Kreis mit R",[122,396,397],{},[19,398,399],{},"Rauchmelder",[122,401,402],{},"Fluchtwege (Flur, Treppenhaus), regional unterschiedlich",[24,404,405],{},[15,406,407,410],{},[19,408,409],{},"Tipp:"," Verwenden Sie ausschließlich die AREI-Symbole. Eigene Fantasie-Symbole werden bei der Kontrolle beanstandet.",[45,412],{},[48,414,416],{"id":415},"schritt-3-komponenten-einzeichnen","Schritt 3: Komponenten einzeichnen",[15,418,419],{},"Jetzt platzieren Sie die Symbole im Grundriss. Folgende Regeln helfen bei der korrekten Positionierung:",[53,421,423],{"id":422},"steckdosen","Steckdosen",[66,425,426,431,437,443,449],{},[69,427,428,430],{},[19,429,306],{}," einzeichnen, an der tatsächlichen Position.",[69,432,433,436],{},[19,434,435],{},"Küche:"," Arbeitsfläche mind. 4 Steckdosen, davon 2 über der Arbeitsplatte. Dedizierte Steckdosen für Backofen, Geschirrspüler, Kühlschrank.",[69,438,439,442],{},[19,440,441],{},"Wohnräume:"," Mind. 1 Steckdose pro angefangene 4 m² (Praxisempfehlung der Installateurverbände — das AREI schreibt keine Mindestanzahl von Steckdosen pro Fläche vor).",[69,444,445,448],{},[19,446,447],{},"Badezimmer:"," Niederspannungs-Steckdosen erst ab Bereich 2 (nur bei Badewannen, mit 30mA-FI) bzw. außerhalb der Bereiche. Bei Duschen existiert Bereich 2 nicht (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[69,450,451,454],{},[19,452,453],{},"Außen:"," Falls Außensteckdose vorhanden, muss sie wettergeschützt (IP44) und mit eigenem 30-mA-FI-Schutz abgesichert sein.",[53,456,458],{"id":457},"schalter","Schalter",[66,460,461,467,472],{},[69,462,463,466],{},[19,464,465],{},"Neben der Tür"," auf der Öffnungsseite, ca. 105 cm Höhe (Praxisempfehlung -- das AREI schreibt keine spezifische Schalthöhe vor, fordert aber 'leicht zugänglich').",[69,468,469,471],{},[19,470,351],{}," bei Räumen mit mehreren Eingängen oder am Treppenanfang\u002F-ende.",[69,473,474,475,478],{},"Verbinden Sie Schalter und zugehörige Leuchten mit einer ",[19,476,477],{},"gestrichelten Linie",".",[53,480,482],{"id":481},"leuchten","Leuchten",[66,484,485,491,497],{},[69,486,487,490],{},[19,488,489],{},"Deckenleuchten"," in die Raummitte oder an die geplante Position.",[69,492,493,496],{},[19,494,495],{},"Wandleuchten"," an der Wandposition.",[69,498,499,500,478],{},"Jeder Raum braucht mindestens ",[19,501,502],{},"einen Lichtpunkt",[53,504,399],{"id":505},"rauchmelder",[15,507,508],{},"Seit dem belgischen Brandschutzgesetz Pflicht (regional unterschiedlich):",[66,510,511,518,524,530],{},[69,512,513,514,517],{},"In ",[19,515,516],{},"Flandern:"," Pflicht in Fluchtwegen (Flure, Treppenhäuser); in Schlafzimmern empfohlen, aber nicht vorgeschrieben.",[69,519,513,520,523],{},[19,521,522],{},"Wallonien und Brüssel"," gelten eigene Regelungen.",[69,525,526,529],{},[19,527,528],{},"Flure und Treppenhäuser"," — mindestens ein Rauchmelder pro Etage.",[69,531,532],{},"In der Küche optional (Hitzemelder bevorzugt wegen Fehlalarmen).",[53,534,536],{"id":535},"sonderverbraucher","Sonderverbraucher",[66,538,539,545,551],{},[69,540,541,544],{},[19,542,543],{},"Wallbox"," (Elektroauto): Garage oder Außenwand, eigener Stromkreis.",[69,546,547,550],{},[19,548,549],{},"Boiler\u002FDurchlauferhitzer:"," Eigener Stromkreis, Position einzeichnen.",[69,552,553,556],{},[19,554,555],{},"Wärmepumpe\u002FKlimaanlage:"," Außeneinheit + Inneneinheit markieren.",[45,558],{},[48,560,562],{"id":561},"schritt-4-stromkreisnummern-zuordnen","Schritt 4: Stromkreisnummern zuordnen",[15,564,565,566,569],{},"Jede Komponente im Situationsplan erhält die ",[19,567,568],{},"gleiche Stromkreisnummer"," wie im Eindrahtschema. Das ist essentiell für die Zuordnung bei der Kontrolle.",[15,571,572],{},[19,573,574],{},"So funktioniert es:",[576,577,578,581,584],"ol",{},[69,579,580],{},"Nummerieren Sie Ihre Stromkreise im Eindrahtschema durch (1, 2, 3, ...).",[69,582,583],{},"Schreiben Sie die Nummer an jede Komponente im Situationsplan.",[69,585,586],{},"Verwenden Sie einheitliche Notation: z. B. „K1\" für Stromkreis 1 oder einfach „1\".",[15,588,589],{},[19,590,591],{},"Beispiel:",[66,593,594,597,600,603],{},[69,595,596],{},"Stromkreis 1: Beleuchtung Erdgeschoss → Alle Leuchten im EG erhalten „1\".",[69,598,599],{},"Stromkreis 2: Steckdosen Wohnzimmer → Alle WZ-Steckdosen erhalten „2\".",[69,601,602],{},"Stromkreis 3: Steckdosen Küche → Alle KÜ-Steckdosen erhalten „3\".",[69,604,605],{},"Stromkreis 4: Dediziert Backofen → Eine Steckdose mit „4\".",[24,607,608,617],{},[15,609,610,612,613,616],{},[19,611,64],{}," Die Nummern müssen zwischen Eindrahtschema und Situationsplan ",[19,614,615],{},"exakt übereinstimmen",". Inkonsistenzen sind einer der häufigsten Gründe für eine Beanstandung bei der Kontrolle.",[15,618,619,622],{},[19,620,621],{},"Dokumentationspflicht:"," Art. 9.1.2 Nr. 1 (Einstrich-Schema) und Art. 9.1.2 Nr. 2 (Lageplan\u002FSituationsplan).",[45,624],{},[48,626,628],{"id":627},"schritt-5-legende-und-beschriftung","Schritt 5: Legende und Beschriftung",[15,630,631],{},"Ergänzen Sie Ihren Plan um:",[66,633,634,640,646,652],{},[69,635,636,639],{},[19,637,638],{},"Legende"," mit allen verwendeten Symbolen und ihrer Bedeutung.",[69,641,642,645],{},[19,643,644],{},"Titelblock"," (Cartouche) mit: Name des Eigentümers, Adresse, Datum, Planersteller, Maßstab.",[69,647,648,651],{},[19,649,650],{},"Nordpfeil"," (optional, aber hilfreich).",[69,653,654,657],{},[19,655,656],{},"Stockwerk-Kennzeichnung"," bei mehrgeschossigen Gebäuden (ein Plan pro Etage).",[45,659],{},[48,661,663],{"id":662},"häufige-fehler","Häufige Fehler",[98,665,666,679],{},[101,667,668],{},[104,669,670,673,676],{},[107,671,672],{},"Fehler",[107,674,675],{},"Konsequenz",[107,677,678],{},"Lösung",[117,680,681,692,703,714,724,735,745],{},[104,682,683,686,689],{},[122,684,685],{},"Fehlende Rauchmelder",[122,687,688],{},"Kontrolle nicht bestanden",[122,690,691],{},"Mind. 1 pro Etage in Fluchtwegen (regional unterschiedlich)",[104,693,694,697,700],{},[122,695,696],{},"Außensteckdose nicht normgerecht",[122,698,699],{},"Beanstandung, falls vorhanden aber nicht konform",[122,701,702],{},"Wenn installiert: IP44, eigener 30-mA-FI-Schutz. Eine fehlende Außensteckdose ist kein Durchfallgrund",[104,704,705,708,711],{},[122,706,707],{},"Fehlende Beschriftung \u002F Stromkreisnummern",[122,709,710],{},"Beanstandung",[122,712,713],{},"Jede Komponente nummerieren",[104,715,716,719,721],{},[122,717,718],{},"Falsche Symbole",[122,720,710],{},[122,722,723],{},"Nur AREI-Tabelle 2.23 verwenden",[104,725,726,729,732],{},[122,727,728],{},"Schalter auf falscher Türseite",[122,730,731],{},"Unpraktisch (kein AREI-Verstoß)",[122,733,734],{},"Öffnungsrichtung prüfen",[104,736,737,740,742],{},[122,738,739],{},"Badezimmer-Steckdose in Bereich 0 oder 1",[122,741,688],{},[122,743,744],{},"Steckdosen erst ab Bereich 2 (nur Badewanne) bzw. außerhalb der Bereiche (Dusche) erlaubt (Art. 7.1.5.2c\u002Fd)",[104,746,747,750,752],{},[122,748,749],{},"Keine Legende",[122,751,710],{},[122,753,754],{},"Symboltabelle beifügen",[45,756],{},[48,758,760],{"id":759},"checkliste-vor-der-abgabe","Checkliste vor der Abgabe",[66,762,765,775,781,787,793,799,805,811,817,823],{"className":763},[764],"contains-task-list",[69,766,769,774],{"className":767},[768],"task-list-item",[770,771],"input",{"disabled":772,"type":773},true,"checkbox"," Alle Räume beschriftet",[69,776,778,780],{"className":777},[768],[770,779],{"disabled":772,"type":773}," Alle Steckdosen, Schalter, Leuchten eingezeichnet",[69,782,784,786],{"className":783},[768],[770,785],{"disabled":772,"type":773}," Rauchmelder in Fluchtwegen (mind. 1 pro Etage, regional unterschiedlich)",[69,788,790,792],{"className":789},[768],[770,791],{"disabled":772,"type":773}," Außensteckdosen, falls vorhanden, normgerecht (IP44, eigener 30-mA-FI)",[69,794,796,798],{"className":795},[768],[770,797],{"disabled":772,"type":773}," Stromkreisnummern an jeder Komponente",[69,800,802,804],{"className":801},[768],[770,803],{"disabled":772,"type":773}," Nummern stimmen mit Eindrahtschema überein",[69,806,808,810],{"className":807},[768],[770,809],{"disabled":772,"type":773}," AREI-Symbole verwendet (Tabelle 2.23)",[69,812,814,816],{"className":813},[768],[770,815],{"disabled":772,"type":773}," Legende vorhanden",[69,818,820,822],{"className":819},[768],[770,821],{"disabled":772,"type":773}," Titelblock mit Name, Adresse, Datum",[69,824,826,828],{"className":825},[768],[770,827],{"disabled":772,"type":773}," Ein Plan pro Stockwerk",[45,830],{},[48,832,834],{"id":833},"verwandte-artikel","Verwandte Artikel",[66,836,837,844,850],{},[69,838,839],{},[840,841,843],"a",{"href":842},"\u002Fde\u002Fblog\u002Fwas-ist-eindrahtschema","Was ist ein Eindrahtschema?",[69,845,846],{},[840,847,849],{"href":848},"\u002Fde\u002Fblog\u002Felektrische-kontrolle","Elektrische Kontrolle in Belgien",[69,851,852],{},[840,853,855],{"href":854},"\u002Fde\u002Fblog\u002Fschaltschrank-planen-aufbau","Schaltschrank planen: Aufbau und Dimensionierung",[45,857],{},[15,859,860],{},[33,861,862,863,866,867],{},"Mit ",[19,864,865],{},"PlanElec"," erstellen Sie Ihren Situationsplan direkt aus dem Grundriss — Räume zeichnen, Geräte per Drag & Drop platzieren, AREI-Symbole werden automatisch verwendet. ",[840,868,870],{"href":869},"\u002F","Jetzt kostenlos testen →",{"title":872,"searchDepth":873,"depth":873,"links":874},"",2,[875,880,881,888,889,890,891,892],{"id":50,"depth":873,"text":51,"children":876},[877,879],{"id":55,"depth":878,"text":56},3,{"id":92,"depth":878,"text":93},{"id":211,"depth":873,"text":212},{"id":415,"depth":873,"text":416,"children":882},[883,884,885,886,887],{"id":422,"depth":878,"text":423},{"id":457,"depth":878,"text":458},{"id":481,"depth":878,"text":482},{"id":505,"depth":878,"text":399},{"id":535,"depth":878,"text":536},{"id":561,"depth":873,"text":562},{"id":627,"depth":873,"text":628},{"id":662,"depth":873,"text":663},{"id":759,"depth":873,"text":760},{"id":833,"depth":873,"text":834},"guide","2026-03-30","Komplette Anleitung zum Erstellen eines AREI-konformen Situationsplans. Von der Grundrissvorbereitung über AREI-Symbole bis zur fertigen Zeichnung.","md","de",{},"\u002Fblog\u002Fdraw-situation-plan.de","8 min",12,{"title":5,"description":895},"situationsplan-zeichnen-anleitung","blog\u002Fdraw-situation-plan.de",[906,907,908,909,910,911,912],"situationsplan","AREI","symbole","anleitung","zeichnen","elektroplan","grundriss","DfLf16mvq0YknMfgWTjjQOz_URm7F2-1t3686ckWq7E",[915,1545,2400,3256],{"id":4,"title":5,"articleId":6,"body":916,"category":893,"date":894,"description":895,"extension":896,"lastUpdated":894,"locale":897,"meta":1542,"navigation":772,"path":899,"publishDate":894,"readTime":900,"refreshInterval":901,"seo":1543,"slug":903,"stem":904,"tags":1544,"__hash__":913},{"type":8,"value":917,"toc":1523},[918,920,924,934,936,938,940,942,944,948,962,964,966,1044,1046,1048,1054,1190,1196,1198,1200,1202,1204,1226,1228,1242,1244,1258,1260,1262,1278,1280,1294,1296,1298,1302,1306,1314,1318,1328,1340,1342,1344,1346,1364,1366,1368,1438,1440,1442,1495,1497,1499,1513,1515],[11,919,5],{"id":13},[15,921,17,922,22],{},[19,923,21],{},[24,925,926],{},[15,927,928,31,930,36,932,40],{},[19,929,30],{},[33,931,35],{},[33,933,39],{},[15,935,43],{},[45,937],{},[48,939,51],{"id":50},[53,941,56],{"id":55},[15,943,59],{},[15,945,946],{},[19,947,64],{},[66,949,950,954,958],{},[69,951,71,952,75],{},[19,953,74],{},[69,955,78,956,82],{},[19,957,81],{},[69,959,85,960,89],{},[19,961,88],{},[53,963,93],{"id":92},[15,965,96],{},[98,967,968,978],{},[101,969,970],{},[104,971,972,974,976],{},[107,973,109],{},[107,975,112],{},[107,977,115],{},[117,979,980,988,996,1004,1012,1020,1028,1036],{},[104,981,982,984,986],{},[122,983,124],{},[122,985,127],{},[122,987,130],{},[104,989,990,992,994],{},[122,991,135],{},[122,993,138],{},[122,995,141],{},[104,997,998,1000,1002],{},[122,999,146],{},[122,1001,149],{},[122,1003,152],{},[104,1005,1006,1008,1010],{},[122,1007,157],{},[122,1009,160],{},[122,1011,163],{},[104,1013,1014,1016,1018],{},[122,1015,168],{},[122,1017,171],{},[122,1019,174],{},[104,1021,1022,1024,1026],{},[122,1023,179],{},[122,1025,182],{},[122,1027,185],{},[104,1029,1030,1032,1034],{},[122,1031,190],{},[122,1033,193],{},[122,1035,196],{},[104,1037,1038,1040,1042],{},[122,1039,201],{},[122,1041,204],{},[122,1043,196],{},[45,1045],{},[48,1047,212],{"id":211},[15,1049,215,1050,219,1052,223],{},[19,1051,218],{},[19,1053,222],{},[98,1055,1056,1068],{},[101,1057,1058],{},[104,1059,1060,1062,1064,1066],{},[107,1061,232],{},[107,1063,235],{},[107,1065,238],{},[107,1067,241],{},[117,1069,1070,1082,1094,1106,1118,1130,1142,1154,1166,1178],{},[104,1071,1072,1074,1076,1080],{},[122,1073,248],{},[122,1075,251],{},[122,1077,1078],{},[19,1079,256],{},[122,1081,259],{},[104,1083,1084,1086,1088,1092],{},[122,1085,264],{},[122,1087,267],{},[122,1089,1090],{},[19,1091,272],{},[122,1093,259],{},[104,1095,1096,1098,1100,1104],{},[122,1097,279],{},[122,1099,282],{},[122,1101,1102],{},[19,1103,287],{},[122,1105,290],{},[104,1107,1108,1110,1112,1116],{},[122,1109,295],{},[122,1111,298],{},[122,1113,1114],{},[19,1115,303],{},[122,1117,306],{},[104,1119,1120,1122,1124,1128],{},[122,1121,311],{},[122,1123,314],{},[122,1125,1126],{},[19,1127,319],{},[122,1129,322],{},[104,1131,1132,1134,1136,1140],{},[122,1133,327],{},[122,1135,330],{},[122,1137,1138],{},[19,1139,335],{},[122,1141,338],{},[104,1143,1144,1146,1148,1152],{},[122,1145,343],{},[122,1147,346],{},[122,1149,1150],{},[19,1151,351],{},[122,1153,354],{},[104,1155,1156,1158,1160,1164],{},[122,1157,359],{},[122,1159,362],{},[122,1161,1162],{},[19,1163,367],{},[122,1165,370],{},[104,1167,1168,1170,1172,1176],{},[122,1169,375],{},[122,1171,378],{},[122,1173,1174],{},[19,1175,383],{},[122,1177,386],{},[104,1179,1180,1182,1184,1188],{},[122,1181,391],{},[122,1183,394],{},[122,1185,1186],{},[19,1187,399],{},[122,1189,402],{},[24,1191,1192],{},[15,1193,1194,410],{},[19,1195,409],{},[45,1197],{},[48,1199,416],{"id":415},[15,1201,419],{},[53,1203,423],{"id":422},[66,1205,1206,1210,1214,1218,1222],{},[69,1207,1208,430],{},[19,1209,306],{},[69,1211,1212,436],{},[19,1213,435],{},[69,1215,1216,442],{},[19,1217,441],{},[69,1219,1220,448],{},[19,1221,447],{},[69,1223,1224,454],{},[19,1225,453],{},[53,1227,458],{"id":457},[66,1229,1230,1234,1238],{},[69,1231,1232,466],{},[19,1233,465],{},[69,1235,1236,471],{},[19,1237,351],{},[69,1239,474,1240,478],{},[19,1241,477],{},[53,1243,482],{"id":481},[66,1245,1246,1250,1254],{},[69,1247,1248,490],{},[19,1249,489],{},[69,1251,1252,496],{},[19,1253,495],{},[69,1255,499,1256,478],{},[19,1257,502],{},[53,1259,399],{"id":505},[15,1261,508],{},[66,1263,1264,1268,1272,1276],{},[69,1265,513,1266,517],{},[19,1267,516],{},[69,1269,513,1270,523],{},[19,1271,522],{},[69,1273,1274,529],{},[19,1275,528],{},[69,1277,532],{},[53,1279,536],{"id":535},[66,1281,1282,1286,1290],{},[69,1283,1284,544],{},[19,1285,543],{},[69,1287,1288,550],{},[19,1289,549],{},[69,1291,1292,556],{},[19,1293,555],{},[45,1295],{},[48,1297,562],{"id":561},[15,1299,565,1300,569],{},[19,1301,568],{},[15,1303,1304],{},[19,1305,574],{},[576,1307,1308,1310,1312],{},[69,1309,580],{},[69,1311,583],{},[69,1313,586],{},[15,1315,1316],{},[19,1317,591],{},[66,1319,1320,1322,1324,1326],{},[69,1321,596],{},[69,1323,599],{},[69,1325,602],{},[69,1327,605],{},[24,1329,1330,1336],{},[15,1331,1332,612,1334,616],{},[19,1333,64],{},[19,1335,615],{},[15,1337,1338,622],{},[19,1339,621],{},[45,1341],{},[48,1343,628],{"id":627},[15,1345,631],{},[66,1347,1348,1352,1356,1360],{},[69,1349,1350,639],{},[19,1351,638],{},[69,1353,1354,645],{},[19,1355,644],{},[69,1357,1358,651],{},[19,1359,650],{},[69,1361,1362,657],{},[19,1363,656],{},[45,1365],{},[48,1367,663],{"id":662},[98,1369,1370,1380],{},[101,1371,1372],{},[104,1373,1374,1376,1378],{},[107,1375,672],{},[107,1377,675],{},[107,1379,678],{},[117,1381,1382,1390,1398,1406,1414,1422,1430],{},[104,1383,1384,1386,1388],{},[122,1385,685],{},[122,1387,688],{},[122,1389,691],{},[104,1391,1392,1394,1396],{},[122,1393,696],{},[122,1395,699],{},[122,1397,702],{},[104,1399,1400,1402,1404],{},[122,1401,707],{},[122,1403,710],{},[122,1405,713],{},[104,1407,1408,1410,1412],{},[122,1409,718],{},[122,1411,710],{},[122,1413,723],{},[104,1415,1416,1418,1420],{},[122,1417,728],{},[122,1419,731],{},[122,1421,734],{},[104,1423,1424,1426,1428],{},[122,1425,739],{},[122,1427,688],{},[122,1429,744],{},[104,1431,1432,1434,1436],{},[122,1433,749],{},[122,1435,710],{},[122,1437,754],{},[45,1439],{},[48,1441,760],{"id":759},[66,1443,1445,1450,1455,1460,1465,1470,1475,1480,1485,1490],{"className":1444},[764],[69,1446,1448,774],{"className":1447},[768],[770,1449],{"disabled":772,"type":773},[69,1451,1453,780],{"className":1452},[768],[770,1454],{"disabled":772,"type":773},[69,1456,1458,786],{"className":1457},[768],[770,1459],{"disabled":772,"type":773},[69,1461,1463,792],{"className":1462},[768],[770,1464],{"disabled":772,"type":773},[69,1466,1468,798],{"className":1467},[768],[770,1469],{"disabled":772,"type":773},[69,1471,1473,804],{"className":1472},[768],[770,1474],{"disabled":772,"type":773},[69,1476,1478,810],{"className":1477},[768],[770,1479],{"disabled":772,"type":773},[69,1481,1483,816],{"className":1482},[768],[770,1484],{"disabled":772,"type":773},[69,1486,1488,822],{"className":1487},[768],[770,1489],{"disabled":772,"type":773},[69,1491,1493,828],{"className":1492},[768],[770,1494],{"disabled":772,"type":773},[45,1496],{},[48,1498,834],{"id":833},[66,1500,1501,1505,1509],{},[69,1502,1503],{},[840,1504,843],{"href":842},[69,1506,1507],{},[840,1508,849],{"href":848},[69,1510,1511],{},[840,1512,855],{"href":854},[45,1514],{},[15,1516,1517],{},[33,1518,862,1519,866,1521],{},[19,1520,865],{},[840,1522,870],{"href":869},{"title":872,"searchDepth":873,"depth":873,"links":1524},[1525,1529,1530,1537,1538,1539,1540,1541],{"id":50,"depth":873,"text":51,"children":1526},[1527,1528],{"id":55,"depth":878,"text":56},{"id":92,"depth":878,"text":93},{"id":211,"depth":873,"text":212},{"id":415,"depth":873,"text":416,"children":1531},[1532,1533,1534,1535,1536],{"id":422,"depth":878,"text":423},{"id":457,"depth":878,"text":458},{"id":481,"depth":878,"text":482},{"id":505,"depth":878,"text":399},{"id":535,"depth":878,"text":536},{"id":561,"depth":873,"text":562},{"id":627,"depth":873,"text":628},{"id":662,"depth":873,"text":663},{"id":759,"depth":873,"text":760},{"id":833,"depth":873,"text":834},{},{"title":5,"description":895},[906,907,908,909,910,911,912],{"id":1546,"title":1547,"articleId":6,"body":1548,"category":893,"date":894,"description":2386,"extension":896,"lastUpdated":894,"locale":2387,"meta":2388,"navigation":772,"path":2389,"publishDate":894,"readTime":900,"refreshInterval":901,"seo":2390,"slug":2391,"stem":2392,"tags":2393,"__hash__":2399},"blog\u002Fblog\u002Fdraw-situation-plan.en.md","Draw a Situation Plan: Step-by-Step Guide According to AREI\u002FRGIE",{"type":8,"value":1549,"toc":2367},[1550,1553,1560,1576,1579,1581,1585,1589,1592,1597,1619,1623,1626,1722,1724,1728,1738,1906,1914,1916,1920,1923,1927,1960,1964,1984,1988,2008,2012,2015,2038,2042,2062,2064,2068,2075,2080,2091,2096,2110,2127,2129,2133,2136,2162,2164,2168,2259,2261,2265,2328,2330,2334,2354,2356],[11,1551,1547],{"id":1552},"draw-a-situation-plan-step-by-step-guide-according-to-areirgie",[15,1554,1555,1556,1559],{},"The situation plan (also called position plan or plan de situation) shows ",[19,1557,1558],{},"where exactly"," each electrical component is located in your building. Together with the single-line diagram, it is one of the two mandatory documents for every electrical installation in Belgium — without it, the inspection by the approved control body will not pass.",[24,1561,1562],{},[15,1563,1564,1567,1568,1571,1572,1575],{},[19,1565,1566],{},"In brief:"," While the single-line diagram shows the ",[33,1569,1570],{},"logical wiring"," (which switch controls which light, via which circuit), the situation plan shows the ",[33,1573,1574],{},"physical position"," of each component on the floor plan.",[15,1577,1578],{},"In this guide, you will learn how to create a standards-compliant situation plan step by step.",[45,1580],{},[48,1582,1584],{"id":1583},"step-1-prepare-the-floor-plan","Step 1: Prepare the Floor Plan",[53,1586,1588],{"id":1587},"dimensions-and-scale","Dimensions and Scale",[15,1590,1591],{},"The floor plan forms the basis of your situation plan. You can take it from a construction plan or draw it yourself.",[15,1593,1594],{},[19,1595,1596],{},"Important:",[66,1598,1599,1606,1612],{},[69,1600,1601,1602,1605],{},"Use a ",[19,1603,1604],{},"uniform scale"," (common: 1:50 or 1:100).",[69,1607,1608,1609,478],{},"Draw all ",[19,1610,1611],{},"walls, doors, and windows",[69,1613,1614,1615,1618],{},"Mark the ",[19,1616,1617],{},"opening direction"," of doors (quarter circle) — this affects switch placement.",[53,1620,1622],{"id":1621},"label-the-rooms","Label the Rooms",[15,1624,1625],{},"Give each room its designation and ideally its area:",[98,1627,1628,1641],{},[101,1629,1630],{},[104,1631,1632,1635,1638],{},[107,1633,1634],{},"Abbreviation",[107,1636,1637],{},"Room",[107,1639,1640],{},"Typical Area",[117,1642,1643,1653,1663,1673,1683,1693,1701,1712],{},[104,1644,1645,1648,1651],{},[122,1646,1647],{},"LR",[122,1649,1650],{},"Living Room",[122,1652,130],{},[104,1654,1655,1658,1661],{},[122,1656,1657],{},"KI",[122,1659,1660],{},"Kitchen",[122,1662,141],{},[104,1664,1665,1668,1671],{},[122,1666,1667],{},"BR",[122,1669,1670],{},"Bedroom",[122,1672,152],{},[104,1674,1675,1678,1681],{},[122,1676,1677],{},"BA",[122,1679,1680],{},"Bathroom",[122,1682,163],{},[104,1684,1685,1688,1691],{},[122,1686,1687],{},"HA",[122,1689,1690],{},"Hallway",[122,1692,174],{},[104,1694,1695,1697,1699],{},[122,1696,179],{},[122,1698,182],{},[122,1700,185],{},[104,1702,1703,1706,1709],{},[122,1704,1705],{},"BS",[122,1707,1708],{},"Basement",[122,1710,1711],{},"variable",[104,1713,1714,1717,1720],{},[122,1715,1716],{},"EX",[122,1718,1719],{},"Exterior",[122,1721,1711],{},[45,1723],{},[48,1725,1727],{"id":1726},"step-2-use-areirgie-symbols","Step 2: Use AREI\u002FRGIE Symbols",[15,1729,1730,1731,1734,1735,1737],{},"The AREI prescribes in ",[19,1732,1733],{},"Table 2.23"," exactly which symbols must be used. These are based on the ",[19,1736,222],{}," standard. Here are the 10 most important symbols for the situation plan:",[98,1739,1740,1755],{},[101,1741,1742],{},[104,1743,1744,1747,1749,1752],{},[107,1745,1746],{},"No.",[107,1748,235],{},[107,1750,1751],{},"Description",[107,1753,1754],{},"Usage",[117,1756,1757,1772,1786,1801,1816,1831,1846,1861,1876,1891],{},[104,1758,1759,1761,1764,1769],{},[122,1760,248],{},[122,1762,1763],{},"⏚ Semicircle",[122,1765,1766],{},[19,1767,1768],{},"Single socket outlet",[122,1770,1771],{},"Mark wall position",[104,1773,1774,1776,1779,1784],{},[122,1775,264],{},[122,1777,1778],{},"⏚⏚ Double semicircle",[122,1780,1781],{},[19,1782,1783],{},"Double socket outlet",[122,1785,1771],{},[104,1787,1788,1790,1793,1798],{},[122,1789,279],{},[122,1791,1792],{},"○ with cross",[122,1794,1795],{},[19,1796,1797],{},"Ceiling light",[122,1799,1800],{},"Centre of room\u002Fposition",[104,1802,1803,1805,1808,1813],{},[122,1804,295],{},[122,1806,1807],{},"─○ with line",[122,1809,1810],{},[19,1811,1812],{},"Wall light",[122,1814,1815],{},"On the wall",[104,1817,1818,1820,1823,1828],{},[122,1819,311],{},[122,1821,1822],{},"Switch symbol",[122,1824,1825],{},[19,1826,1827],{},"Single-pole switch",[122,1829,1830],{},"Next to door (opening side)",[104,1832,1833,1835,1838,1843],{},[122,1834,327],{},[122,1836,1837],{},"Switch symbol with 2 arrows",[122,1839,1840],{},[19,1841,1842],{},"Series switch",[122,1844,1845],{},"Controls 2 luminaires",[104,1847,1848,1850,1853,1858],{},[122,1849,343],{},[122,1851,1852],{},"Switch symbol with line",[122,1854,1855],{},[19,1856,1857],{},"Two-way switch",[122,1859,1860],{},"Two locations, one light",[104,1862,1863,1865,1868,1873],{},[122,1864,359],{},[122,1866,1867],{},"Rectangle with lightning",[122,1869,1870],{},[19,1871,1872],{},"Distribution board",[122,1874,1875],{},"Usually hallway\u002Futility room",[104,1877,1878,1880,1883,1888],{},[122,1879,375],{},[122,1881,1882],{},"⏚ with PE",[122,1884,1885],{},[19,1886,1887],{},"Earth connection",[122,1889,1890],{},"Earthing point",[104,1892,1893,1895,1898,1903],{},[122,1894,391],{},[122,1896,1897],{},"Circle with R",[122,1899,1900],{},[19,1901,1902],{},"Smoke detector",[122,1904,1905],{},"Escape routes (hallway, staircase), regionally varies",[24,1907,1908],{},[15,1909,1910,1913],{},[19,1911,1912],{},"Tip:"," Use only the AREI\u002FRGIE symbols. Self-invented symbols will be rejected during inspection.",[45,1915],{},[48,1917,1919],{"id":1918},"step-3-draw-the-components","Step 3: Draw the Components",[15,1921,1922],{},"Now place the symbols on the floor plan. The following rules help with correct positioning:",[53,1924,1926],{"id":1925},"socket-outlets","Socket Outlets",[66,1928,1929,1936,1942,1948,1954],{},[69,1930,1931,1932,1935],{},"Draw ",[19,1933,1934],{},"on the wall"," at the actual position.",[69,1937,1938,1941],{},[19,1939,1940],{},"Kitchen:"," worktop at least 4 sockets, of which 2 above the counter. Dedicated sockets for oven, dishwasher, refrigerator.",[69,1943,1944,1947],{},[19,1945,1946],{},"Living spaces:"," At least 1 socket per started 4 m² (practical recommendation by installer associations — the AREI does not prescribe a minimum number of sockets per area).",[69,1949,1950,1953],{},[19,1951,1952],{},"Bathroom:"," Low-voltage sockets only from Zone 2 (bathtubs only, with 30mA RCD) or outside the zones. For showers, Zone 2 does not exist (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[69,1955,1956,1959],{},[19,1957,1958],{},"Outdoor:"," If an outdoor socket is installed, it must be weatherproof (IP44) and protected by a dedicated 30mA RCD.",[53,1961,1963],{"id":1962},"switches","Switches",[66,1965,1966,1972,1978],{},[69,1967,1968,1971],{},[19,1969,1970],{},"Next to the door"," on the opening side, approximately 105 cm height (practical recommendation — the AREI does not prescribe a specific switch height, but requires 'easily accessible').",[69,1973,1974,1977],{},[19,1975,1976],{},"Two-way switches"," for rooms with multiple entrances or at the top\u002Fbottom of stairs.",[69,1979,1980,1981,478],{},"Connect switches and associated luminaires with a ",[19,1982,1983],{},"dashed line",[53,1985,1987],{"id":1986},"lighting-points","Lighting Points",[66,1989,1990,1996,2002],{},[69,1991,1992,1995],{},[19,1993,1994],{},"Ceiling lights"," in the centre of the room or at the planned position.",[69,1997,1998,2001],{},[19,1999,2000],{},"Wall lights"," at the wall position.",[69,2003,2004,2005,478],{},"Every room needs at least ",[19,2006,2007],{},"one lighting point",[53,2009,2011],{"id":2010},"smoke-detectors","Smoke Detectors",[15,2013,2014],{},"Mandatory under Belgian fire safety legislation (varies by region):",[66,2016,2017,2023,2029,2035],{},[69,2018,513,2019,2022],{},[19,2020,2021],{},"Flanders:"," Mandatory in escape routes (hallways, staircases); recommended but not required in bedrooms.",[69,2024,513,2025,2028],{},[19,2026,2027],{},"Wallonia and Brussels",", separate regulations apply.",[69,2030,2031,2034],{},[19,2032,2033],{},"Hallways and staircases"," — at least one smoke detector per floor.",[69,2036,2037],{},"In the kitchen optional (heat detector preferred to avoid false alarms).",[53,2039,2041],{"id":2040},"special-consumers","Special Consumers",[66,2043,2044,2050,2056],{},[69,2045,2046,2049],{},[19,2047,2048],{},"EV charger"," (electric vehicle): garage or exterior wall, dedicated circuit.",[69,2051,2052,2055],{},[19,2053,2054],{},"Water heater\u002FBoiler:"," Dedicated circuit, mark the position.",[69,2057,2058,2061],{},[19,2059,2060],{},"Heat pump\u002FAir conditioning:"," Mark outdoor unit + indoor unit.",[45,2063],{},[48,2065,2067],{"id":2066},"step-4-assign-circuit-numbers","Step 4: Assign Circuit Numbers",[15,2069,2070,2071,2074],{},"Each component on the situation plan receives the ",[19,2072,2073],{},"same circuit number"," as in the single-line diagram. This is essential for identification during inspection.",[15,2076,2077],{},[19,2078,2079],{},"How it works:",[576,2081,2082,2085,2088],{},[69,2083,2084],{},"Number your circuits in the single-line diagram (1, 2, 3, ...).",[69,2086,2087],{},"Write the number next to each component on the situation plan.",[69,2089,2090],{},"Use consistent notation: e.g., \"C1\" for circuit 1 or simply \"1\".",[15,2092,2093],{},[19,2094,2095],{},"Example:",[66,2097,2098,2101,2104,2107],{},[69,2099,2100],{},"Circuit 1: Ground floor lighting → All ground floor luminaires get \"1\".",[69,2102,2103],{},"Circuit 2: Living room sockets → All living room sockets get \"2\".",[69,2105,2106],{},"Circuit 3: Kitchen sockets → All kitchen sockets get \"3\".",[69,2108,2109],{},"Circuit 4: Dedicated oven → One socket with \"4\".",[24,2111,2112,2121],{},[15,2113,2114,2116,2117,2120],{},[19,2115,1596],{}," The numbers must match ",[19,2118,2119],{},"exactly"," between the single-line diagram and the situation plan. Inconsistencies are one of the most common reasons for remarks during inspection.",[15,2122,2123,2126],{},[19,2124,2125],{},"Documentation requirement:"," Art. 9.1.2 Nr. 1 (single-line diagram) and Art. 9.1.2 Nr. 2 (situation plan).",[45,2128],{},[48,2130,2132],{"id":2131},"step-5-legend-and-labelling","Step 5: Legend and Labelling",[15,2134,2135],{},"Complete your plan with:",[66,2137,2138,2144,2150,2156],{},[69,2139,2140,2143],{},[19,2141,2142],{},"Legend"," with all symbols used and their meaning.",[69,2145,2146,2149],{},[19,2147,2148],{},"Title block"," (cartouche) with: owner's name, address, date, plan creator, scale.",[69,2151,2152,2155],{},[19,2153,2154],{},"North arrow"," (optional, but helpful).",[69,2157,2158,2161],{},[19,2159,2160],{},"Floor indication"," for multi-storey buildings (one plan per floor).",[45,2163],{},[48,2165,2167],{"id":2166},"common-mistakes","Common Mistakes",[98,2169,2170,2183],{},[101,2171,2172],{},[104,2173,2174,2177,2180],{},[107,2175,2176],{},"Mistake",[107,2178,2179],{},"Consequence",[107,2181,2182],{},"Solution",[117,2184,2185,2196,2207,2218,2228,2239,2249],{},[104,2186,2187,2190,2193],{},[122,2188,2189],{},"Missing smoke detectors",[122,2191,2192],{},"Inspection failed",[122,2194,2195],{},"Min. 1 per floor in escape routes (varies by region)",[104,2197,2198,2201,2204],{},[122,2199,2200],{},"Outdoor socket not compliant",[122,2202,2203],{},"Remark, if present but non-compliant",[122,2205,2206],{},"If installed: IP44, dedicated 30mA RCD. A missing outdoor socket is not a fail reason",[104,2208,2209,2212,2215],{},[122,2210,2211],{},"Missing labels \u002F circuit numbers",[122,2213,2214],{},"Remark",[122,2216,2217],{},"Number every component",[104,2219,2220,2223,2225],{},[122,2221,2222],{},"Wrong symbols",[122,2224,2214],{},[122,2226,2227],{},"Use only AREI Table 2.23",[104,2229,2230,2233,2236],{},[122,2231,2232],{},"Switch on wrong side of door",[122,2234,2235],{},"Impractical (not an AREI violation)",[122,2237,2238],{},"Check opening direction",[104,2240,2241,2244,2246],{},[122,2242,2243],{},"Bathroom socket in Zone 0 or 1",[122,2245,2192],{},[122,2247,2248],{},"Sockets only from Zone 2 (bathtub) or outside the zones (shower) (Art. 7.1.5.2c\u002Fd)",[104,2250,2251,2254,2256],{},[122,2252,2253],{},"No legend",[122,2255,2214],{},[122,2257,2258],{},"Include symbol table",[45,2260],{},[48,2262,2264],{"id":2263},"checklist-before-submission","Checklist Before Submission",[66,2266,2268,2274,2280,2286,2292,2298,2304,2310,2316,2322],{"className":2267},[764],[69,2269,2271,2273],{"className":2270},[768],[770,2272],{"disabled":772,"type":773}," All rooms labelled",[69,2275,2277,2279],{"className":2276},[768],[770,2278],{"disabled":772,"type":773}," All sockets, switches, lighting points drawn",[69,2281,2283,2285],{"className":2282},[768],[770,2284],{"disabled":772,"type":773}," Smoke detectors in escape routes (min. 1 per floor, varies by region)",[69,2287,2289,2291],{"className":2288},[768],[770,2290],{"disabled":772,"type":773}," Outdoor sockets, if installed, compliant (IP44, dedicated 30mA RCD)",[69,2293,2295,2297],{"className":2294},[768],[770,2296],{"disabled":772,"type":773}," Circuit numbers on every component",[69,2299,2301,2303],{"className":2300},[768],[770,2302],{"disabled":772,"type":773}," Numbers match the single-line diagram",[69,2305,2307,2309],{"className":2306},[768],[770,2308],{"disabled":772,"type":773}," AREI symbols used (Table 2.23)",[69,2311,2313,2315],{"className":2312},[768],[770,2314],{"disabled":772,"type":773}," Legend present",[69,2317,2319,2321],{"className":2318},[768],[770,2320],{"disabled":772,"type":773}," Title block with name, address, date",[69,2323,2325,2327],{"className":2324},[768],[770,2326],{"disabled":772,"type":773}," One plan per floor",[45,2329],{},[48,2331,2333],{"id":2332},"related-articles","Related Articles",[66,2335,2336,2342,2348],{},[69,2337,2338],{},[840,2339,2341],{"href":2340},"\u002Fen\u002Fblog\u002Fwhat-is-single-line-diagram","What Is a Single-Line Diagram?",[69,2343,2344],{},[840,2345,2347],{"href":2346},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical Inspection in Belgium",[69,2349,2350],{},[840,2351,2353],{"href":2352},"\u002Fen\u002Fblog\u002Fdistribution-board-planning-guide","Distribution Board Planning: Layout and Sizing",[45,2355],{},[15,2357,2358],{},[33,2359,2360,2361,2363,2364],{},"With ",[19,2362,865],{},", create your situation plan directly from the floor plan — draw rooms, drag and drop devices, AREI symbols are used automatically. ",[840,2365,2366],{"href":869},"Try for free →",{"title":872,"searchDepth":873,"depth":873,"links":2368},[2369,2373,2374,2381,2382,2383,2384,2385],{"id":1583,"depth":873,"text":1584,"children":2370},[2371,2372],{"id":1587,"depth":878,"text":1588},{"id":1621,"depth":878,"text":1622},{"id":1726,"depth":873,"text":1727},{"id":1918,"depth":873,"text":1919,"children":2375},[2376,2377,2378,2379,2380],{"id":1925,"depth":878,"text":1926},{"id":1962,"depth":878,"text":1963},{"id":1986,"depth":878,"text":1987},{"id":2010,"depth":878,"text":2011},{"id":2040,"depth":878,"text":2041},{"id":2066,"depth":873,"text":2067},{"id":2131,"depth":873,"text":2132},{"id":2166,"depth":873,"text":2167},{"id":2263,"depth":873,"text":2264},{"id":2332,"depth":873,"text":2333},"Complete guide to creating an AREI\u002FRGIE-compliant situation plan. From floor plan preparation to AREI symbols to the finished drawing.","en",{},"\u002Fblog\u002Fdraw-situation-plan.en",{"title":1547,"description":2386},"draw-situation-plan-guide","blog\u002Fdraw-situation-plan.en",[2394,907,2395,893,2396,2397,2398],"situation plan","symbols","drawing","electrical plan","floor plan","OnIT3y4v8bkN1c21nJzgibxhZsBL8fX__6YUoqGuORc",{"id":2401,"title":2402,"articleId":6,"body":2403,"category":893,"date":894,"description":3241,"extension":896,"lastUpdated":894,"locale":3242,"meta":3243,"navigation":772,"path":3244,"publishDate":894,"readTime":900,"refreshInterval":901,"seo":3245,"slug":3246,"stem":3247,"tags":3248,"__hash__":3255},"blog\u002Fblog\u002Fdraw-situation-plan.fr.md","Dessiner un plan de situation : Guide étape par étape selon le RGIE",{"type":8,"value":2404,"toc":3222},[2405,2408,2415,2431,2434,2436,2440,2444,2447,2452,2474,2478,2481,2577,2579,2583,2593,2761,2769,2771,2775,2778,2782,2815,2819,2839,2843,2863,2867,2870,2894,2898,2918,2920,2924,2931,2936,2947,2952,2966,2983,2985,2989,2992,3018,3020,3024,3114,3116,3120,3183,3185,3189,3209,3211],[11,2406,2402],{"id":2407},"dessiner-un-plan-de-situation-guide-étape-par-étape-selon-le-rgie",[15,2409,2410,2411,2414],{},"Le plan de situation (aussi appelé schéma de position) montre ",[19,2412,2413],{},"où exactement"," chaque composant électrique se trouve dans votre bâtiment. Avec le schéma unifilaire, c'est l'un des deux documents obligatoires pour toute installation électrique en Belgique — sans lui, le contrôle par l'organisme agréé ne sera pas réussi.",[24,2416,2417],{},[15,2418,2419,2422,2423,2426,2427,2430],{},[19,2420,2421],{},"En bref :"," Tandis que le schéma unifilaire représente le ",[33,2424,2425],{},"raccordement logique"," (quel interrupteur commande quel luminaire, via quel circuit), le plan de situation montre la ",[33,2428,2429],{},"position physique"," de chaque composant sur le plan d'étage.",[15,2432,2433],{},"Dans ce guide, vous apprendrez comment créer un plan de situation conforme aux normes, étape par étape.",[45,2435],{},[48,2437,2439],{"id":2438},"étape-1-préparer-le-plan-détage","Étape 1 : Préparer le plan d'étage",[53,2441,2443],{"id":2442},"dimensions-et-échelle","Dimensions et échelle",[15,2445,2446],{},"Le plan d'étage constitue la base de votre plan de situation. Vous pouvez le reprendre d'un plan de construction ou le dessiner vous-même.",[15,2448,2449],{},[19,2450,2451],{},"Important :",[66,2453,2454,2461,2467],{},[69,2455,2456,2457,2460],{},"Utilisez une ",[19,2458,2459],{},"échelle uniforme"," (courante : 1:50 ou 1:100).",[69,2462,2463,2464,478],{},"Dessinez tous les ",[19,2465,2466],{},"murs, portes et fenêtres",[69,2468,2469,2470,2473],{},"Marquez le ",[19,2471,2472],{},"sens d'ouverture"," des portes (quart de cercle) — cela influence la position des interrupteurs.",[53,2475,2477],{"id":2476},"étiqueter-les-pièces","Étiqueter les pièces",[15,2479,2480],{},"Identifiez chaque pièce avec sa désignation et idéalement sa surface :",[98,2482,2483,2496],{},[101,2484,2485],{},[104,2486,2487,2490,2493],{},[107,2488,2489],{},"Abréviation",[107,2491,2492],{},"Pièce",[107,2494,2495],{},"Surface typique",[117,2497,2498,2508,2518,2528,2538,2548,2557,2567],{},[104,2499,2500,2503,2506],{},[122,2501,2502],{},"SÉJ",[122,2504,2505],{},"Séjour",[122,2507,130],{},[104,2509,2510,2513,2516],{},[122,2511,2512],{},"CUI",[122,2514,2515],{},"Cuisine",[122,2517,141],{},[104,2519,2520,2523,2526],{},[122,2521,2522],{},"CH",[122,2524,2525],{},"Chambre",[122,2527,152],{},[104,2529,2530,2533,2536],{},[122,2531,2532],{},"SDB",[122,2534,2535],{},"Salle de bain",[122,2537,163],{},[104,2539,2540,2543,2546],{},[122,2541,2542],{},"COU",[122,2544,2545],{},"Couloir",[122,2547,174],{},[104,2549,2550,2553,2555],{},[122,2551,2552],{},"GAR",[122,2554,182],{},[122,2556,185],{},[104,2558,2559,2562,2565],{},[122,2560,2561],{},"CAV",[122,2563,2564],{},"Cave",[122,2566,1711],{},[104,2568,2569,2572,2575],{},[122,2570,2571],{},"EXT",[122,2573,2574],{},"Extérieur",[122,2576,1711],{},[45,2578],{},[48,2580,2582],{"id":2581},"étape-2-utiliser-les-symboles-rgie","Étape 2 : Utiliser les symboles RGIE",[15,2584,2585,2586,2589,2590,2592],{},"Le RGIE prescrit dans le ",[19,2587,2588],{},"Tableau 2.23"," exactement quels symboles doivent être utilisés. Ceux-ci sont basés sur la norme ",[19,2591,222],{},". Voici les 10 symboles les plus importants pour le plan de situation :",[98,2594,2595,2610],{},[101,2596,2597],{},[104,2598,2599,2602,2605,2607],{},[107,2600,2601],{},"N°",[107,2603,2604],{},"Symbole",[107,2606,1751],{},[107,2608,2609],{},"Utilisation",[117,2611,2612,2627,2641,2656,2671,2686,2701,2716,2731,2746],{},[104,2613,2614,2616,2619,2624],{},[122,2615,248],{},[122,2617,2618],{},"⏚ Demi-cercle",[122,2620,2621],{},[19,2622,2623],{},"Prise simple",[122,2625,2626],{},"Marquer position murale",[104,2628,2629,2631,2634,2639],{},[122,2630,264],{},[122,2632,2633],{},"⏚⏚ Double demi-cercle",[122,2635,2636],{},[19,2637,2638],{},"Prise double",[122,2640,2626],{},[104,2642,2643,2645,2648,2653],{},[122,2644,279],{},[122,2646,2647],{},"○ avec croix",[122,2649,2650],{},[19,2651,2652],{},"Plafonnier",[122,2654,2655],{},"Centre de la pièce\u002Fposition",[104,2657,2658,2660,2663,2668],{},[122,2659,295],{},[122,2661,2662],{},"─○ avec trait",[122,2664,2665],{},[19,2666,2667],{},"Applique murale",[122,2669,2670],{},"Sur le mur",[104,2672,2673,2675,2678,2683],{},[122,2674,311],{},[122,2676,2677],{},"Symbole interrupteur",[122,2679,2680],{},[19,2681,2682],{},"Interrupteur unipolaire",[122,2684,2685],{},"À côté de la porte (côté ouverture)",[104,2687,2688,2690,2693,2698],{},[122,2689,327],{},[122,2691,2692],{},"Symbole interrupteur 2 flèches",[122,2694,2695],{},[19,2696,2697],{},"Interrupteur sériel",[122,2699,2700],{},"Commande 2 luminaires",[104,2702,2703,2705,2708,2713],{},[122,2704,343],{},[122,2706,2707],{},"Symbole interrupteur avec ligne",[122,2709,2710],{},[19,2711,2712],{},"Interrupteur va-et-vient",[122,2714,2715],{},"Deux points, un luminaire",[104,2717,2718,2720,2723,2728],{},[122,2719,359],{},[122,2721,2722],{},"Rectangle avec éclair",[122,2724,2725],{},[19,2726,2727],{},"Tableau de distribution",[122,2729,2730],{},"Généralement couloir\u002Flocal technique",[104,2732,2733,2735,2738,2743],{},[122,2734,375],{},[122,2736,2737],{},"⏚ avec PE",[122,2739,2740],{},[19,2741,2742],{},"Prise de terre",[122,2744,2745],{},"Point de mise à la terre",[104,2747,2748,2750,2753,2758],{},[122,2749,391],{},[122,2751,2752],{},"Cercle avec R",[122,2754,2755],{},[19,2756,2757],{},"Détecteur de fumée",[122,2759,2760],{},"Chaque chambre, couloir, cage d'escalier",[24,2762,2763],{},[15,2764,2765,2768],{},[19,2766,2767],{},"Conseil :"," Utilisez exclusivement les symboles RGIE. Des symboles inventés seront refusés lors du contrôle.",[45,2770],{},[48,2772,2774],{"id":2773},"étape-3-dessiner-les-composants","Étape 3 : Dessiner les composants",[15,2776,2777],{},"Placez maintenant les symboles sur le plan d'étage. Les règles suivantes aident au positionnement correct :",[53,2779,2781],{"id":2780},"prises-de-courant","Prises de courant",[66,2783,2784,2791,2797,2803,2809],{},[69,2785,2786,2787,2790],{},"Dessiner ",[19,2788,2789],{},"sur le mur",", à la position réelle.",[69,2792,2793,2796],{},[19,2794,2795],{},"Cuisine :"," plan de travail minimum 4 prises, dont 2 au-dessus du plan de travail. Prises dédiées pour four, lave-vaisselle, réfrigérateur.",[69,2798,2799,2802],{},[19,2800,2801],{},"Pièces de vie :"," Min. 1 prise par tranche de 4 m² entamée (recommandation pratique des associations d'installateurs — le RGIE ne prescrit pas de nombre minimum de prises par surface).",[69,2804,2805,2808],{},[19,2806,2807],{},"Salle de bain :"," Prises basse tension à partir de la zone 2 (uniquement pour les baignoires, avec différentiel 30mA) ou hors zones. Pour les douches, la zone 2 n'existe pas (art. 7.1.3.2 n° 3b, art. 7.1.5.2d).",[69,2810,2811,2814],{},[19,2812,2813],{},"Extérieur :"," Si une prise extérieure est installée, elle doit être protégée contre les intempéries (IP44) et sécurisée par son propre différentiel 30mA.",[53,2816,2818],{"id":2817},"interrupteurs","Interrupteurs",[66,2820,2821,2827,2833],{},[69,2822,2823,2826],{},[19,2824,2825],{},"À côté de la porte"," du côté de l'ouverture, à environ 105 cm de hauteur (recommandation pratique — le RGIE ne prescrit pas de hauteur spécifique pour les interrupteurs, mais exige qu'ils soient « facilement accessibles »).",[69,2828,2829,2832],{},[19,2830,2831],{},"Interrupteurs va-et-vient"," pour les pièces à plusieurs entrées ou en début\u002Ffin d'escalier.",[69,2834,2835,2836,478],{},"Reliez les interrupteurs et les luminaires associés par une ",[19,2837,2838],{},"ligne pointillée",[53,2840,2842],{"id":2841},"points-lumineux","Points lumineux",[66,2844,2845,2851,2857],{},[69,2846,2847,2850],{},[19,2848,2849],{},"Plafonniers"," au centre de la pièce ou à la position prévue.",[69,2852,2853,2856],{},[19,2854,2855],{},"Appliques murales"," à la position sur le mur.",[69,2858,2859,2860,478],{},"Chaque pièce nécessite au minimum ",[19,2861,2862],{},"un point lumineux",[53,2864,2866],{"id":2865},"détecteurs-de-fumée","Détecteurs de fumée",[15,2868,2869],{},"Obligatoires selon la législation belge sur la sécurité incendie (varie selon la région) :",[66,2871,2872,2879,2885,2891],{},[69,2873,2874,2875,2878],{},"En ",[19,2876,2877],{},"Flandre :"," Obligatoire dans les voies d'évacuation (couloirs, cages d'escalier) ; dans les chambres recommandé, mais pas obligatoire.",[69,2880,2874,2881,2884],{},[19,2882,2883],{},"Wallonie et Bruxelles"," : des réglementations propres s'appliquent.",[69,2886,2887,2890],{},[19,2888,2889],{},"Couloirs et cages d'escalier"," — au minimum un détecteur de fumée par étage.",[69,2892,2893],{},"Dans la cuisine optionnel (détecteur de chaleur préféré pour éviter les fausses alarmes).",[53,2895,2897],{"id":2896},"consommateurs-spéciaux","Consommateurs spéciaux",[66,2899,2900,2906,2912],{},[69,2901,2902,2905],{},[19,2903,2904],{},"Borne de recharge"," (véhicule électrique) : garage ou mur extérieur, circuit dédié.",[69,2907,2908,2911],{},[19,2909,2910],{},"Chauffe-eau\u002FBoiler :"," Circuit dédié, dessiner la position.",[69,2913,2914,2917],{},[19,2915,2916],{},"Pompe à chaleur\u002FClimatisation :"," Marquer unité extérieure + unité intérieure.",[45,2919],{},[48,2921,2923],{"id":2922},"étape-4-attribuer-les-numéros-de-circuits","Étape 4 : Attribuer les numéros de circuits",[15,2925,2926,2927,2930],{},"Chaque composant du plan de situation reçoit le ",[19,2928,2929],{},"même numéro de circuit"," que dans le schéma unifilaire. C'est essentiel pour l'attribution lors du contrôle.",[15,2932,2933],{},[19,2934,2935],{},"Comment ça marche :",[576,2937,2938,2941,2944],{},[69,2939,2940],{},"Numérotez vos circuits dans le schéma unifilaire (1, 2, 3, ...).",[69,2942,2943],{},"Inscrivez le numéro à côté de chaque composant sur le plan de situation.",[69,2945,2946],{},"Utilisez une notation uniforme : par ex. « C1 » pour circuit 1 ou simplement « 1 ».",[15,2948,2949],{},[19,2950,2951],{},"Exemple :",[66,2953,2954,2957,2960,2963],{},[69,2955,2956],{},"Circuit 1 : Éclairage rez-de-chaussée → Tous les luminaires du RDC reçoivent « 1 ».",[69,2958,2959],{},"Circuit 2 : Prises séjour → Toutes les prises du séjour reçoivent « 2 ».",[69,2961,2962],{},"Circuit 3 : Prises cuisine → Toutes les prises de cuisine reçoivent « 3 ».",[69,2964,2965],{},"Circuit 4 : Dédié four → Une prise avec « 4 ».",[24,2967,2968,2977],{},[15,2969,2970,2972,2973,2976],{},[19,2971,2451],{}," Les numéros doivent correspondre ",[19,2974,2975],{},"exactement"," entre le schéma unifilaire et le plan de situation. Les incohérences sont l'une des causes les plus fréquentes de remarques lors du contrôle.",[15,2978,2979,2982],{},[19,2980,2981],{},"Obligation de documentation :"," Art. 9.1.2 n° 1 (schéma unifilaire) et art. 9.1.2 n° 2 (plan de situation).",[45,2984],{},[48,2986,2988],{"id":2987},"étape-5-légende-et-étiquetage","Étape 5 : Légende et étiquetage",[15,2990,2991],{},"Complétez votre plan avec :",[66,2993,2994,3000,3006,3012],{},[69,2995,2996,2999],{},[19,2997,2998],{},"Légende"," avec tous les symboles utilisés et leur signification.",[69,3001,3002,3005],{},[19,3003,3004],{},"Cartouche"," avec : nom du propriétaire, adresse, date, auteur du plan, échelle.",[69,3007,3008,3011],{},[19,3009,3010],{},"Flèche nord"," (optionnel, mais utile).",[69,3013,3014,3017],{},[19,3015,3016],{},"Indication d'étage"," pour les bâtiments à plusieurs niveaux (un plan par étage).",[45,3019],{},[48,3021,3023],{"id":3022},"erreurs-fréquentes","Erreurs fréquentes",[98,3025,3026,3038],{},[101,3027,3028],{},[104,3029,3030,3033,3036],{},[107,3031,3032],{},"Erreur",[107,3034,3035],{},"Conséquence",[107,3037,2182],{},[117,3039,3040,3051,3062,3073,3083,3094,3104],{},[104,3041,3042,3045,3048],{},[122,3043,3044],{},"Détecteurs de fumée manquants",[122,3046,3047],{},"Contrôle non réussi",[122,3049,3050],{},"Min. 1 par étage dans les voies d'évacuation (varie selon la région)",[104,3052,3053,3056,3059],{},[122,3054,3055],{},"Prise extérieure non conforme",[122,3057,3058],{},"Remarque, si installée mais non conforme",[122,3060,3061],{},"Si installée : IP44, différentiel 30mA dédié. L'absence de prise extérieure n'est pas un motif de refus",[104,3063,3064,3067,3070],{},[122,3065,3066],{},"Étiquetage \u002F numéros de circuits manquants",[122,3068,3069],{},"Remarque",[122,3071,3072],{},"Numéroter chaque composant",[104,3074,3075,3078,3080],{},[122,3076,3077],{},"Mauvais symboles",[122,3079,3069],{},[122,3081,3082],{},"Utiliser uniquement le Tableau 2.23 du RGIE",[104,3084,3085,3088,3091],{},[122,3086,3087],{},"Interrupteur du mauvais côté de la porte",[122,3089,3090],{},"Non pratique (pas d'infraction RGIE)",[122,3092,3093],{},"Vérifier le sens d'ouverture",[104,3095,3096,3099,3101],{},[122,3097,3098],{},"Prise salle de bain en zone 0 ou 1",[122,3100,3047],{},[122,3102,3103],{},"Prises à partir de la zone 2 (baignoire uniquement) ou hors zones (douche) (art. 7.1.5.2c\u002Fd)",[104,3105,3106,3109,3111],{},[122,3107,3108],{},"Pas de légende",[122,3110,3069],{},[122,3112,3113],{},"Joindre un tableau de symboles",[45,3115],{},[48,3117,3119],{"id":3118},"checklist-avant-soumission","Checklist avant soumission",[66,3121,3123,3129,3135,3141,3147,3153,3159,3165,3171,3177],{"className":3122},[764],[69,3124,3126,3128],{"className":3125},[768],[770,3127],{"disabled":772,"type":773}," Toutes les pièces étiquetées",[69,3130,3132,3134],{"className":3131},[768],[770,3133],{"disabled":772,"type":773}," Toutes les prises, interrupteurs, luminaires dessinés",[69,3136,3138,3140],{"className":3137},[768],[770,3139],{"disabled":772,"type":773}," Détecteurs de fumée dans les voies d'évacuation (min. 1 par étage, varie selon la région)",[69,3142,3144,3146],{"className":3143},[768],[770,3145],{"disabled":772,"type":773}," Prises extérieures, si installées, conformes (IP44, différentiel 30mA dédié)",[69,3148,3150,3152],{"className":3149},[768],[770,3151],{"disabled":772,"type":773}," Numéros de circuits sur chaque composant",[69,3154,3156,3158],{"className":3155},[768],[770,3157],{"disabled":772,"type":773}," Les numéros correspondent au schéma unifilaire",[69,3160,3162,3164],{"className":3161},[768],[770,3163],{"disabled":772,"type":773}," Symboles RGIE utilisés (Tableau 2.23)",[69,3166,3168,3170],{"className":3167},[768],[770,3169],{"disabled":772,"type":773}," Légende présente",[69,3172,3174,3176],{"className":3173},[768],[770,3175],{"disabled":772,"type":773}," Cartouche avec nom, adresse, date",[69,3178,3180,3182],{"className":3179},[768],[770,3181],{"disabled":772,"type":773}," Un plan par étage",[45,3184],{},[48,3186,3188],{"id":3187},"articles-connexes","Articles connexes",[66,3190,3191,3197,3203],{},[69,3192,3193],{},[840,3194,3196],{"href":3195},"\u002Ffr\u002Fblog\u002Fquest-ce-quun-schema-unifilaire","Qu'est-ce qu'un schéma unifilaire ?",[69,3198,3199],{},[840,3200,3202],{"href":3201},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique",[69,3204,3205],{},[840,3206,3208],{"href":3207},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique : Conception et dimensionnement",[45,3210],{},[15,3212,3213],{},[33,3214,3215,3216,3218,3219],{},"Avec ",[19,3217,865],{},", créez votre plan de situation directement à partir du plan d'étage — dessinez les pièces, placez les appareils par glisser-déposer, les symboles RGIE sont utilisés automatiquement. ",[840,3220,3221],{"href":869},"Essayer gratuitement →",{"title":872,"searchDepth":873,"depth":873,"links":3223},[3224,3228,3229,3236,3237,3238,3239,3240],{"id":2438,"depth":873,"text":2439,"children":3225},[3226,3227],{"id":2442,"depth":878,"text":2443},{"id":2476,"depth":878,"text":2477},{"id":2581,"depth":873,"text":2582},{"id":2773,"depth":873,"text":2774,"children":3230},[3231,3232,3233,3234,3235],{"id":2780,"depth":878,"text":2781},{"id":2817,"depth":878,"text":2818},{"id":2841,"depth":878,"text":2842},{"id":2865,"depth":878,"text":2866},{"id":2896,"depth":878,"text":2897},{"id":2922,"depth":873,"text":2923},{"id":2987,"depth":873,"text":2988},{"id":3022,"depth":873,"text":3023},{"id":3118,"depth":873,"text":3119},{"id":3187,"depth":873,"text":3188},"Guide complet pour créer un plan de situation conforme au RGIE. De la préparation du plan d'étage aux symboles RGIE jusqu'au dessin finalisé.","fr",{},"\u002Fblog\u002Fdraw-situation-plan.fr",{"title":2402,"description":3241},"dessiner-plan-situation-guide","blog\u002Fdraw-situation-plan.fr",[3249,3250,3251,893,3252,3253,3254],"plan de situation","RGIE","symboles","dessin","plan électrique","plan d'étage","Wpc9xEfZ3BkiZ-yjisU3MCnVQpz9GYOIyWWdtvj0PRA",{"id":3257,"title":3258,"articleId":6,"body":3259,"category":893,"date":894,"description":4093,"extension":896,"lastUpdated":894,"locale":4094,"meta":4095,"navigation":772,"path":4096,"publishDate":894,"readTime":900,"refreshInterval":901,"seo":4097,"slug":4098,"stem":4099,"tags":4100,"__hash__":4106},"blog\u002Fblog\u002Fdraw-situation-plan.nl.md","Situatieschema tekenen: Stap-voor-stap handleiding volgens AREI",{"type":8,"value":3260,"toc":4074},[3261,3264,3271,3287,3290,3292,3296,3300,3303,3308,3331,3335,3338,3431,3433,3437,3447,3615,3622,3624,3628,3631,3635,3667,3671,3691,3695,3716,3720,3723,3746,3750,3770,3772,3776,3783,3788,3799,3804,3818,3835,3837,3841,3844,3869,3871,3875,3966,3968,3972,4035,4037,4041,4061,4063],[11,3262,3258],{"id":3263},"situatieschema-tekenen-stap-voor-stap-handleiding-volgens-arei",[15,3265,3266,3267,3270],{},"Het situatieschema (ook wel situatieplan of plan de situation) toont ",[19,3268,3269],{},"waar precies"," elk elektrisch onderdeel zich in uw gebouw bevindt. Samen met het éénlijnschema is het één van de twee verplichte documenten voor elke elektrische installatie in België — zonder situatieschema slaagt de keuring door het erkend controleorganisme niet.",[24,3272,3273],{},[15,3274,3275,3278,3279,3282,3283,3286],{},[19,3276,3277],{},"Kort uitgelegd:"," Terwijl het éénlijnschema de ",[33,3280,3281],{},"logische schakeling"," weergeeft (welke schakelaar bedient welk lichtpunt, via welk circuit), toont het situatieschema de ",[33,3284,3285],{},"fysieke positie"," van elk onderdeel op het grondplan.",[15,3288,3289],{},"In deze handleiding leert u hoe u stap voor stap een normconform situatieschema maakt.",[45,3291],{},[48,3293,3295],{"id":3294},"stap-1-grondplan-voorbereiden","Stap 1: Grondplan voorbereiden",[53,3297,3299],{"id":3298},"afmetingen-en-schaal","Afmetingen en schaal",[15,3301,3302],{},"Het grondplan vormt de basis van uw situatieschema. U kunt het overnemen van een bouwplan of zelf tekenen.",[15,3304,3305],{},[19,3306,3307],{},"Belangrijk:",[66,3309,3310,3317,3324],{},[69,3311,3312,3313,3316],{},"Gebruik een ",[19,3314,3315],{},"uniforme schaal"," (gebruikelijk: 1:50 of 1:100).",[69,3318,3319,3320,3323],{},"Teken alle ",[19,3321,3322],{},"muren, deuren en ramen"," in.",[69,3325,3326,3327,3330],{},"Markeer de ",[19,3328,3329],{},"openingsrichting"," van deuren (kwartcirkel) — dit beïnvloedt de schakelaarspositie.",[53,3332,3334],{"id":3333},"ruimtes-labelen","Ruimtes labelen",[15,3336,3337],{},"Voorzie elke ruimte van een benaming en idealiter het oppervlak:",[98,3339,3340,3353],{},[101,3341,3342],{},[104,3343,3344,3347,3350],{},[107,3345,3346],{},"Afkorting",[107,3348,3349],{},"Ruimte",[107,3351,3352],{},"Typisch oppervlak",[117,3354,3355,3365,3374,3384,3394,3403,3411,3421],{},[104,3356,3357,3360,3363],{},[122,3358,3359],{},"WK",[122,3361,3362],{},"Woonkamer",[122,3364,130],{},[104,3366,3367,3369,3372],{},[122,3368,190],{},[122,3370,3371],{},"Keuken",[122,3373,141],{},[104,3375,3376,3379,3382],{},[122,3377,3378],{},"SK",[122,3380,3381],{},"Slaapkamer",[122,3383,152],{},[104,3385,3386,3389,3392],{},[122,3387,3388],{},"BK",[122,3390,3391],{},"Badkamer",[122,3393,163],{},[104,3395,3396,3398,3401],{},[122,3397,1687],{},[122,3399,3400],{},"Hal\u002FGang",[122,3402,174],{},[104,3404,3405,3407,3409],{},[122,3406,179],{},[122,3408,182],{},[122,3410,185],{},[104,3412,3413,3416,3419],{},[122,3414,3415],{},"KL",[122,3417,3418],{},"Kelder",[122,3420,196],{},[104,3422,3423,3426,3429],{},[122,3424,3425],{},"BU",[122,3427,3428],{},"Buitenzone",[122,3430,196],{},[45,3432],{},[48,3434,3436],{"id":3435},"stap-2-arei-symbolen-gebruiken","Stap 2: AREI-symbolen gebruiken",[15,3438,3439,3440,3443,3444,3446],{},"Het AREI schrijft in ",[19,3441,3442],{},"Tabel 2.23"," precies voor welke symbolen gebruikt moeten worden. Deze zijn gebaseerd op de norm ",[19,3445,222],{},". Hier de 10 belangrijkste symbolen voor het situatieschema:",[98,3448,3449,3464],{},[101,3450,3451],{},[104,3452,3453,3455,3458,3461],{},[107,3454,232],{},[107,3456,3457],{},"Symbool",[107,3459,3460],{},"Beschrijving",[107,3462,3463],{},"Gebruik",[117,3465,3466,3481,3495,3510,3525,3540,3555,3570,3585,3600],{},[104,3467,3468,3470,3473,3478],{},[122,3469,248],{},[122,3471,3472],{},"⏚ Halve cirkel",[122,3474,3475],{},[19,3476,3477],{},"Enkel stopcontact",[122,3479,3480],{},"Wandpositie markeren",[104,3482,3483,3485,3488,3493],{},[122,3484,264],{},[122,3486,3487],{},"⏚⏚ Dubbele halve cirkel",[122,3489,3490],{},[19,3491,3492],{},"Dubbel stopcontact",[122,3494,3480],{},[104,3496,3497,3499,3502,3507],{},[122,3498,279],{},[122,3500,3501],{},"○ met kruis",[122,3503,3504],{},[19,3505,3506],{},"Plafondlamp",[122,3508,3509],{},"Midden van de ruimte\u002Fpositie",[104,3511,3512,3514,3517,3522],{},[122,3513,295],{},[122,3515,3516],{},"─○ met streep",[122,3518,3519],{},[19,3520,3521],{},"Wandlamp",[122,3523,3524],{},"Aan de wand",[104,3526,3527,3529,3532,3537],{},[122,3528,311],{},[122,3530,3531],{},"Schakelaarsteken",[122,3533,3534],{},[19,3535,3536],{},"Enkelpolige schakelaar",[122,3538,3539],{},"Naast de deur (openingszijde)",[104,3541,3542,3544,3547,3552],{},[122,3543,327],{},[122,3545,3546],{},"Schakelaarsteken met 2 pijlen",[122,3548,3549],{},[19,3550,3551],{},"Serieschakelaar",[122,3553,3554],{},"Bedient 2 lichtpunten",[104,3556,3557,3559,3562,3567],{},[122,3558,343],{},[122,3560,3561],{},"Schakelaarsteken met lijn",[122,3563,3564],{},[19,3565,3566],{},"Wisselschakelaar",[122,3568,3569],{},"Twee plaatsen, één licht",[104,3571,3572,3574,3577,3582],{},[122,3573,359],{},[122,3575,3576],{},"Rechthoek met bliksem",[122,3578,3579],{},[19,3580,3581],{},"Verdeelkast",[122,3583,3584],{},"Meestal hal\u002Ftechnische ruimte",[104,3586,3587,3589,3592,3597],{},[122,3588,375],{},[122,3590,3591],{},"⏚ met PE",[122,3593,3594],{},[19,3595,3596],{},"Aardingsaansluiting",[122,3598,3599],{},"Aardingspunt",[104,3601,3602,3604,3607,3612],{},[122,3603,391],{},[122,3605,3606],{},"Cirkel met R",[122,3608,3609],{},[19,3610,3611],{},"Rookmelder",[122,3613,3614],{},"Elke slaapkamer, hal, trappenhuis",[24,3616,3617],{},[15,3618,3619,3621],{},[19,3620,1912],{}," Gebruik uitsluitend de AREI-symbolen. Eigen verzonnen symbolen worden bij de keuring afgekeurd.",[45,3623],{},[48,3625,3627],{"id":3626},"stap-3-componenten-intekenen","Stap 3: Componenten intekenen",[15,3629,3630],{},"Nu plaatst u de symbolen op het grondplan. Volgende regels helpen bij de correcte positionering:",[53,3632,3634],{"id":3633},"stopcontacten","Stopcontacten",[66,3636,3637,3643,3649,3655,3661],{},[69,3638,3639,3642],{},[19,3640,3641],{},"Op de wand"," tekenen, op de werkelijke positie.",[69,3644,3645,3648],{},[19,3646,3647],{},"Keuken:"," werkblad minstens 4 stopcontacten, waarvan 2 boven het werkblad. Aparte stopcontacten voor oven, vaatwasser, koelkast.",[69,3650,3651,3654],{},[19,3652,3653],{},"Woonruimtes:"," Minstens 1 stopcontact per begonnen 4 m² (praktijkaanbeveling van de installateurverenigingen — het AREI schrijft geen minimumaantal stopcontacten per oppervlakte voor).",[69,3656,3657,3660],{},[19,3658,3659],{},"Badkamer:"," Laagspanningsstopcontacten pas vanaf zone 2 (alleen bij badkuipen, met 30mA differentieel) of buiten de zones. Bij douches bestaat zone 2 niet (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[69,3662,3663,3666],{},[19,3664,3665],{},"Buiten:"," Indien aanwezig, moet een buitenstopcontact weerbestendig zijn (IP44) en met eigen 30mA differentieel beveiligd zijn.",[53,3668,3670],{"id":3669},"schakelaars","Schakelaars",[66,3672,3673,3679,3685],{},[69,3674,3675,3678],{},[19,3676,3677],{},"Naast de deur"," aan de openingszijde, ca. 105 cm hoogte (praktijkaanbeveling — het AREI schrijft geen specifieke schakelaarhoogte voor, maar vereist wel 'gemakkelijk bereikbaar').",[69,3680,3681,3684],{},[19,3682,3683],{},"Wisselschakelaars"," bij ruimtes met meerdere ingangen of aan het begin\u002Feinde van de trap.",[69,3686,3687,3688,478],{},"Verbind schakelaars en bijbehorende lichtpunten met een ",[19,3689,3690],{},"stippellijn",[53,3692,3694],{"id":3693},"verlichtingspunten","Verlichtingspunten",[66,3696,3697,3703,3709],{},[69,3698,3699,3702],{},[19,3700,3701],{},"Plafondlampen"," in het midden van de ruimte of op de geplande positie.",[69,3704,3705,3708],{},[19,3706,3707],{},"Wandlampen"," op de wandpositie.",[69,3710,3711,3712,3715],{},"Elke ruimte heeft minstens ",[19,3713,3714],{},"één lichtpunt"," nodig.",[53,3717,3719],{"id":3718},"rookmelders","Rookmelders",[15,3721,3722],{},"Verplicht volgens de Belgische brandveiligheidswetgeving (regionaal verschillend):",[66,3724,3725,3731,3737,3743],{},[69,3726,513,3727,3730],{},[19,3728,3729],{},"Vlaanderen:"," Verplicht in vluchtwegen (gangen, trappenhuizen); in slaapkamers aanbevolen maar niet verplicht.",[69,3732,513,3733,3736],{},[19,3734,3735],{},"Wallonië en Brussel"," gelden eigen regelingen.",[69,3738,3739,3742],{},[19,3740,3741],{},"Gangen en trappenhuizen"," — minstens een rookmelder per verdieping.",[69,3744,3745],{},"In de keuken optioneel (hittemelder heeft de voorkeur wegens vals alarm).",[53,3747,3749],{"id":3748},"speciale-verbruikers","Speciale verbruikers",[66,3751,3752,3758,3764],{},[69,3753,3754,3757],{},[19,3755,3756],{},"Laadpaal"," (elektrisch voertuig): garage of buitenmuur, eigen circuit.",[69,3759,3760,3763],{},[19,3761,3762],{},"Boiler\u002FDoorstromer:"," Eigen circuit, positie intekenen.",[69,3765,3766,3769],{},[19,3767,3768],{},"Warmtepomp\u002FAirco:"," Buitenunit + binnenunit markeren.",[45,3771],{},[48,3773,3775],{"id":3774},"stap-4-circuitnummers-toewijzen","Stap 4: Circuitnummers toewijzen",[15,3777,3778,3779,3782],{},"Elk onderdeel in het situatieschema krijgt ",[19,3780,3781],{},"hetzelfde circuitnummer"," als in het éénlijnschema. Dit is essentieel voor de toewijzing bij de keuring.",[15,3784,3785],{},[19,3786,3787],{},"Zo werkt het:",[576,3789,3790,3793,3796],{},[69,3791,3792],{},"Nummer uw circuits in het éénlijnschema (1, 2, 3, ...).",[69,3794,3795],{},"Schrijf het nummer bij elk onderdeel in het situatieschema.",[69,3797,3798],{},"Gebruik een uniforme notatie: bijv. \"K1\" voor kring 1 of gewoon \"1\".",[15,3800,3801],{},[19,3802,3803],{},"Voorbeeld:",[66,3805,3806,3809,3812,3815],{},[69,3807,3808],{},"Circuit 1: Verlichting gelijkvloers → Alle lichtpunten op het gelijkvloers krijgen \"1\".",[69,3810,3811],{},"Circuit 2: Stopcontacten woonkamer → Alle WK-stopcontacten krijgen \"2\".",[69,3813,3814],{},"Circuit 3: Stopcontacten keuken → Alle KE-stopcontacten krijgen \"3\".",[69,3816,3817],{},"Circuit 4: Apart oven → Eén stopcontact met \"4\".",[24,3819,3820,3829],{},[15,3821,3822,3824,3825,3828],{},[19,3823,3307],{}," De nummers moeten tussen éénlijnschema en situatieschema ",[19,3826,3827],{},"exact overeenkomen",". Inconsistenties zijn een van de meest voorkomende redenen voor opmerkingen bij de keuring.",[15,3830,3831,3834],{},[19,3832,3833],{},"Documentatieplicht:"," Art. 9.1.2 Nr. 1 (éénlijnschema) en Art. 9.1.2 Nr. 2 (situatieschema\u002Flageplan).",[45,3836],{},[48,3838,3840],{"id":3839},"stap-5-legende-en-opschrift","Stap 5: Legende en opschrift",[15,3842,3843],{},"Vul uw plan aan met:",[66,3845,3846,3851,3857,3863],{},[69,3847,3848,3850],{},[19,3849,638],{}," met alle gebruikte symbolen en hun betekenis.",[69,3852,3853,3856],{},[19,3854,3855],{},"Titelblok"," (cartouche) met: naam eigenaar, adres, datum, planmaker, schaal.",[69,3858,3859,3862],{},[19,3860,3861],{},"Noordpijl"," (optioneel, maar nuttig).",[69,3864,3865,3868],{},[19,3866,3867],{},"Verdiepingsaanduiding"," bij gebouwen met meerdere verdiepingen (één plan per verdieping).",[45,3870],{},[48,3872,3874],{"id":3873},"veelgemaakte-fouten","Veelgemaakte fouten",[98,3876,3877,3890],{},[101,3878,3879],{},[104,3880,3881,3884,3887],{},[107,3882,3883],{},"Fout",[107,3885,3886],{},"Gevolg",[107,3888,3889],{},"Oplossing",[117,3891,3892,3903,3914,3925,3935,3946,3956],{},[104,3893,3894,3897,3900],{},[122,3895,3896],{},"Ontbrekende rookmelders",[122,3898,3899],{},"Keuring niet geslaagd",[122,3901,3902],{},"Min. 1 per verdieping in vluchtwegen (regionaal verschillend)",[104,3904,3905,3908,3911],{},[122,3906,3907],{},"Buitenstopcontact niet normconform",[122,3909,3910],{},"Opmerking, indien aanwezig maar niet conform",[122,3912,3913],{},"Indien geïnstalleerd: IP44, eigen 30mA differentieel. Een ontbrekend buitenstopcontact is geen reden voor afkeuring",[104,3915,3916,3919,3922],{},[122,3917,3918],{},"Ontbrekende opschriften \u002F circuitnummers",[122,3920,3921],{},"Opmerking",[122,3923,3924],{},"Elk onderdeel nummeren",[104,3926,3927,3930,3932],{},[122,3928,3929],{},"Verkeerde symbolen",[122,3931,3921],{},[122,3933,3934],{},"Alleen AREI Tabel 2.23 gebruiken",[104,3936,3937,3940,3943],{},[122,3938,3939],{},"Schakelaar aan verkeerde deurzijde",[122,3941,3942],{},"Onpraktisch (geen AREI-overtreding)",[122,3944,3945],{},"Openingsrichting controleren",[104,3947,3948,3951,3953],{},[122,3949,3950],{},"Badkamer-stopcontact in zone 0 of 1",[122,3952,3899],{},[122,3954,3955],{},"Stopcontacten pas vanaf zone 2 (alleen badkuip) of buiten de zones (douche) toegelaten (Art. 7.1.5.2c\u002Fd)",[104,3957,3958,3961,3963],{},[122,3959,3960],{},"Geen legende",[122,3962,3921],{},[122,3964,3965],{},"Symbooltabel bijvoegen",[45,3967],{},[48,3969,3971],{"id":3970},"checklist-voor-indiening","Checklist voor indiening",[66,3973,3975,3981,3987,3993,3999,4005,4011,4017,4023,4029],{"className":3974},[764],[69,3976,3978,3980],{"className":3977},[768],[770,3979],{"disabled":772,"type":773}," Alle ruimtes gelabeld",[69,3982,3984,3986],{"className":3983},[768],[770,3985],{"disabled":772,"type":773}," Alle stopcontacten, schakelaars, lichtpunten ingetekend",[69,3988,3990,3992],{"className":3989},[768],[770,3991],{"disabled":772,"type":773}," Rookmelders in vluchtwegen (min. 1 per verdieping, regionaal verschillend)",[69,3994,3996,3998],{"className":3995},[768],[770,3997],{"disabled":772,"type":773}," Buitenstopcontacten, indien aanwezig, normconform (IP44, eigen 30mA differentieel)",[69,4000,4002,4004],{"className":4001},[768],[770,4003],{"disabled":772,"type":773}," Circuitnummers bij elk onderdeel",[69,4006,4008,4010],{"className":4007},[768],[770,4009],{"disabled":772,"type":773}," Nummers komen overeen met éénlijnschema",[69,4012,4014,4016],{"className":4013},[768],[770,4015],{"disabled":772,"type":773}," AREI-symbolen gebruikt (Tabel 2.23)",[69,4018,4020,4022],{"className":4019},[768],[770,4021],{"disabled":772,"type":773}," Legende aanwezig",[69,4024,4026,4028],{"className":4025},[768],[770,4027],{"disabled":772,"type":773}," Titelblok met naam, adres, datum",[69,4030,4032,4034],{"className":4031},[768],[770,4033],{"disabled":772,"type":773}," Eén plan per verdieping",[45,4036],{},[48,4038,4040],{"id":4039},"gerelateerde-artikelen","Gerelateerde artikelen",[66,4042,4043,4049,4055],{},[69,4044,4045],{},[840,4046,4048],{"href":4047},"\u002Fblog\u002Fwat-is-eenlijnschema","Wat is een éénlijnschema?",[69,4050,4051],{},[840,4052,4054],{"href":4053},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België",[69,4056,4057],{},[840,4058,4060],{"href":4059},"\u002Fblog\u002Fverdeelkast-plannen-opbouw","Verdeelkast plannen: Opbouw en dimensionering",[45,4062],{},[15,4064,4065],{},[33,4066,4067,4068,4070,4071],{},"Met ",[19,4069,865],{}," maakt u uw situatieschema rechtstreeks vanuit het grondplan — ruimtes tekenen, apparaten slepen en neerzetten, AREI-symbolen worden automatisch gebruikt. ",[840,4072,4073],{"href":869},"Nu gratis uitproberen →",{"title":872,"searchDepth":873,"depth":873,"links":4075},[4076,4080,4081,4088,4089,4090,4091,4092],{"id":3294,"depth":873,"text":3295,"children":4077},[4078,4079],{"id":3298,"depth":878,"text":3299},{"id":3333,"depth":878,"text":3334},{"id":3435,"depth":873,"text":3436},{"id":3626,"depth":873,"text":3627,"children":4082},[4083,4084,4085,4086,4087],{"id":3633,"depth":878,"text":3634},{"id":3669,"depth":878,"text":3670},{"id":3693,"depth":878,"text":3694},{"id":3718,"depth":878,"text":3719},{"id":3748,"depth":878,"text":3749},{"id":3774,"depth":873,"text":3775},{"id":3839,"depth":873,"text":3840},{"id":3873,"depth":873,"text":3874},{"id":3970,"depth":873,"text":3971},{"id":4039,"depth":873,"text":4040},"Volledige handleiding voor het maken van een AREI-conform situatieschema. Van de grondplanvoorbereiding via AREI-symbolen tot de afgewerkte tekening.","nl",{},"\u002Fblog\u002Fdraw-situation-plan.nl",{"title":3258,"description":4093},"situatieschema-tekenen-handleiding","blog\u002Fdraw-situation-plan.nl",[4101,907,4102,4103,4104,911,4105],"situatieschema","symbolen","handleiding","tekenen","grondplan","xX_iD9De_y0ZulcG-M5dx4Pg6-zcCmVgi-8BfBtEtC8",1775151657841]