[{"data":1,"prerenderedAt":1835},["ShallowReactive",2],{"blog-post-en-solar-pv-situation-plan":3,"blog-alternates-pv-situation-plan":417},{"id":4,"title":5,"articleId":6,"body":7,"category":395,"date":396,"description":397,"extension":398,"lastUpdated":396,"locale":399,"meta":400,"navigation":401,"path":402,"publishDate":396,"readTime":403,"refreshInterval":404,"seo":405,"slug":406,"stem":407,"tags":408,"__hash__":416},"blog\u002Fblog\u002Fpv-situation-plan.en.md","Drawing Solar PV on a Situation Plan: Modules, Inverter and Cable Routes","pv-situation-plan",{"type":8,"value":9,"toc":371},"minimark",[10,19,22,27,30,55,58,62,65,82,91,95,98,115,118,122,125,128,139,142,146,149,166,174,178,181,184,199,207,211,216,219,223,226,230,233,237,240,244,247,267,270,274,294,298,301,304,308,311,314,317,321,324,327,331,334,337,346,350,358,362],[11,12,13,14,18],"p",{},"PV documentation often focuses on the single-line diagram, where strings, inverter, protection and the distribution-board connection appear. A situation plan has a different purpose: recording the ",[15,16,17],"strong",{},"physical location"," of fixed electrical equipment. For later maintenance, alteration or inspection, a reader should find the module fields, inverter and fixed route back to the board.",[11,20,21],{},"The situation plan is neither a roof-structure design nor a duplicate DC schematic. It complements the single-line diagram without repeating all of its electrical detail.",[23,24,26],"h2",{"id":25},"start-from-an-as-built-survey","Start from an as-built survey",[11,28,29],{},"Use a recognisable plan with storeys, rooms, access points and important external areas. A roof plan or elevation may be needed. Verify on site:",[31,32,33,37,40,43,46,49,52],"ul",{},[34,35,36],"li",{},"actual module fields and orientation;",[34,38,39],{},"central inverters or microinverters;",[34,41,42],{},"fixed DC and AC isolation points where installed;",[34,44,45],{},"main or sub-distribution board receiving the PV connection;",[34,47,48],{},"fixed penetrations and important cable routes;",[34,50,51],{},"meter cabinet where needed to explain the connection;",[34,53,54],{},"battery, backup switching or another source included in the system.",[11,56,57],{},"Do not copy the quotation drawing without checking it. Module layout, inverter location and cable route frequently change during installation.",[23,59,61],{"id":60},"what-to-show-on-the-roof","What to show on the roof",[11,63,64],{},"Make the module field unambiguous. Depending on scale, show:",[31,66,67,70,73,76,79],{},[34,68,69],{},"individual modules or clearly bounded module groups;",[34,71,72],{},"the relevant roof pitch, outbuilding, façade or ground area;",[34,74,75],{},"string references where they connect the plan to the single-line diagram;",[34,77,78],{},"fixed DC combiner or switching boxes;",[34,80,81],{},"useful roof edges, access points or fire compartments where they explain electrical location.",[11,83,84,85,90],{},"The plan does not need every connector beneath every module. String arrangement, polarity, conductor data and electrical protection primarily belong on the ",[86,87,89],"a",{"href":88},"\u002Fen\u002Fblog\u002Fpv-system-diagram","PV single-line diagram",". Use identical string and equipment identifiers on both documents.",[23,92,94],{"id":93},"locate-the-inverter-precisely","Locate the inverter precisely",[11,96,97],{},"Mark the actual mounting position and distinguish where relevant:",[31,99,100,103,106,109,112],{},[34,101,102],{},"central string inverter;",[34,104,105],{},"multiple inverters;",[34,107,108],{},"microinverters at the modules;",[34,110,111],{},"hybrid inverter and separate battery;",[34,113,114],{},"associated fixed isolation or switching devices.",[11,116,117],{},"A label saying only “garage” may be too vague in a large space. Put the symbol at the correct wall or technical zone. Identify the façade when equipment is outside.",[23,119,121],{"id":120},"draw-useful-cable-routes","Draw useful cable routes",[11,123,124],{},"A serviceable plan shows how the fixed electrical route runs from module field to inverter and onward to the board. Include building penetrations, risers, ducts and changes of level that will later be concealed.",[11,126,127],{},"Distinguish DC and AC routes by line style or text, not colour alone. A black-and-white print must remain understandable:",[129,130,136],"pre",{"className":131,"code":133,"language":134,"meta":135},[132],"language-text","PV-DC  ─ ─ ─  DC route from the module field\nPV-AC  ─────  AC route to the distribution board\nDATA   ·····  fixed metering or communication route\n","text","",[137,138,133],"code",{"__ignoreMap":135},[11,140,141],{},"Define each line in the legend. It does not state cable type or installation method; those data remain attached to the circuit on the single-line diagram.",[23,143,145],{"id":144},"symbols-and-project-legend","Symbols and project legend",[11,147,148],{},"Table 2.23 of AREI Book 1 V06 is non-exhaustive. A project symbol for a module field, inverter or DC isolator may be used when it is unambiguous and defined in the legend. Ensure:",[31,150,151,154,157,160,163],{},[34,152,153],{},"sufficient size in the final PDF;",[34,155,156],{},"different form or text for inverter and battery;",[34,158,159],{},"stable references across pages;",[34,161,162],{},"meaning that does not rely only on colour;",[34,164,165],{},"clear distinction between electrical equipment and building objects.",[11,167,168,169,173],{},"The ",[86,170,172],{"href":171},"\u002Fen\u002Fblog\u002Farei-electrical-symbols-overview","AREI electrical-symbol overview"," explains the legend rule in more detail.",[23,175,177],{"id":176},"share-references-with-the-single-line-diagram","Share references with the single-line diagram",[11,179,180],{},"Part 3 of AREI Book 1 V06 links the two plans through circuit references. The inverter AC branch therefore carries the same identifier on the situation plan and single-line diagram. String and equipment references used on both must also agree.",[11,182,183],{},"Check in both directions:",[185,186,187,190,193,196],"ol",{},[34,188,189],{},"Every fixed PV item on the situation plan can be found on the single-line diagram or in its legend.",[34,191,192],{},"Every spatially relevant PV component on the single-line diagram has a discoverable position.",[34,194,195],{},"Board and storey names match.",[34,197,198],{},"Address, date and document revision are the same.",[11,200,201,202,206],{},"See ",[86,203,205],{"href":204},"\u002Fen\u002Fblog\u002Fsingle-line-diagram-vs-situation-plan","single-line diagram versus situation plan"," for their separate roles.",[23,208,210],{"id":209},"special-configurations","Special configurations",[212,213,215],"h3",{"id":214},"microinverters","Microinverters",[11,217,218],{},"For many identical units, a grouped symbol with quantity, type and related modules may be clearer than overlapping marks. The electrical parallel connection remains visible on the single-line diagram.",[212,220,222],{"id":221},"home-battery","Home battery",[11,224,225],{},"Locate the battery, inverter, fixed isolation and any backup board. A battery is not a PV module and needs a distinct symbol. Location constraints come from design and manufacturer information; the plan records the installed position.",[212,227,229],{"id":228},"outbuilding-or-ground-array","Outbuilding or ground array",[11,231,232],{},"Show the route between buildings, entry point and any sub-board. An arrow marked “to house” without a precise destination is poor evidence for future work.",[212,234,236],{"id":235},"existing-installation","Existing installation",[11,238,239],{},"Part 8 contains a limited derogation for certain existing domestic PV installations up to 10 kVA, allowing a written description possibly supported by photographs. Do not generalise that existing-installation rule to new construction or a significant alteration. Have the particular case classified correctly.",[23,241,243],{"id":242},"dossier-and-photographs","Dossier and photographs",[11,245,246],{},"Photographs help document concealed routes, roofs and equipment labels, but do not automatically replace structured electrical plans. Retain:",[31,248,249,252,255,258,261,264],{},[34,250,251],{},"final situation plan and single-line diagram;",[34,253,254],{},"module and inverter data;",[34,256,257],{},"available string and measurement records;",[34,259,260],{},"manuals and equipment declarations;",[34,262,263],{},"reports from the recognised inspection body;",[34,265,266],{},"later changes under a new revision.",[11,268,269],{},"The owner should keep the dossier available and arrange updates after alterations.",[23,271,273],{"id":272},"pre-export-check","Pre-export check",[31,275,276,279,282,285,288,291],{},[34,277,278],{},"Are module fields, inverters and fixed auxiliary devices at their actual locations?",[34,280,281],{},"Are DC and AC routes distinguishable and explained in the legend?",[34,283,284],{},"Do circuit, string and board references match the single-line diagram?",[34,286,287],{},"Are symbols and labels legible at the intended print size?",[34,289,290],{},"Does the plan represent as-built conditions rather than the original offer?",[34,292,293],{},"Do both plans carry the same address, date and revision?",[23,295,297],{"id":296},"organising-a-multi-sheet-plan","Organising a multi-sheet plan",[11,299,300],{},"If the roof, technical room and boards cannot fit legibly on one sheet, use named views. An overview can connect the building, roof areas and distribution boards while detail sheets enlarge arrays and equipment zones. Number every sheet and use explicit continuation notes such as “PV-DC continues on sheet S2”.",[11,302,303],{},"Keep enough orientation on each view: storey, room, north arrow or recognisable façade. Do not repeat one equipment identifier at several positions unless several devices really exist. A reference table can link symbol, equipment ID, circuit and sheet. This keeps a large installation traceable without shrinking labels or drawing long ambiguous lines across the page.",[23,305,307],{"id":306},"worked-case-two-roof-faces-and-one-inverter-in-a-plant-room","Worked case: two roof faces and one inverter in a plant room",[11,309,310],{},"Consider a house with modules on east- and west-facing roofs, two DC strings and one inverter in the plant room. Show two identified array areas rather than one icon at the centre of the roof. State which string reference belongs to each face and where its DC conductors enter the building. Draw a shared route to the plant room only where the installed cables really share that route.",[11,312,313],{},"Give the inverter a stable equipment reference and its actual wall position. If DC isolation, surge protection or other fixed equipment is external, locate it too and link its identifier to the single-line diagram. Keep integrated functions attached to the equipment record rather than inventing separate boxes. The AC route ends at the correct board and circuit; a line aimed merely at the nearest room adds no traceability.",[11,315,316],{},"Check the orientation of each roof detail. Roof face, eaves, ridge, north direction and recognisable building edges should let a person find the array and entry point on site. The position plan is not a mechanical mounting drawing and need not show every hook. It should show differences that matter for electrical assignment, safe work and later fault finding.",[23,318,320],{"id":319},"survey-concealed-or-inaccessible-routes-honestly","Survey concealed or inaccessible routes honestly",[11,322,323],{},"Do not invent a geometrically precise path where an existing installation hides it. Mark a section as concealed or derived from retained documentation and keep the source of that information. Photographs of entries, labels, penetrations and the plant room help narrow the uncertainty. A dashed line has that meaning only when the legend defines it.",[11,325,326],{},"Separate three evidence states: observed on site, supported by reliable technical records and still unresolved. Open items belong in a survey task list, not as confident lines on the final drawing. Before inspection, the responsible professional decides whether more surveying or access is required.",[23,328,330],{"id":329},"carry-roof-alterations-through-the-documents","Carry roof alterations through the documents",[11,332,333],{},"After replacing modules, extending an array or changing an inverter, review more than the roof outline. Update array and string identifiers, cable route, entry point, equipment location, DC and AC references and supporting technical records. Even where modules are replaced within an existing string, retain the actual installed quantity and rating in the relevant dossier information. If strings are rearranged, the single-line and position plan must share the new state.",[11,335,336],{},"Archive the superseded edition separately with its date. This makes clear whether a photograph or inspection report concerns the old or current arrangement. An inverter cloud portal can provide production data, but it is not a spatial survey and does not replace the position-plan revision.",[11,338,168,339,345],{},[86,340,344],{"href":341,"rel":342},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fthemes\u002Fenergie\u002Fsources-et-vecteurs-denergie\u002Felectricite\u002Fsecurite-et-controle-des\u002Fcontrole-des-installations",[343],"nofollow","official FPS Economy page on domestic electrical inspections"," explicitly includes energy sources on both diagrams and PV technical documentation in the dossier. The required detail follows the installation and current official Book 1 V06, not a generic roof template.",[23,347,349],{"id":348},"creating-the-plan-in-planelec","Creating the plan in PlanElec",[11,351,352,353,357],{},"With ",[86,354,356],{"href":355},"\u002Fen\u002F","PlanElec",", you can place PV components on the situation plan, record their electrical structure on the single-line diagram and export both as PDFs. The software reproduces the project data entered. Its indicative self-check can flag supported information, but does not replace an on-site survey or recognised inspection and does not certify AREI compliance.",[23,359,361],{"id":360},"sources-and-reviewed-version","Sources and reviewed version",[11,363,364,365,370],{},"The basis is the official ",[86,366,369],{"href":367,"rel":368},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[343],"AREI\u002FRGIE Book 1 publication",": Table 2.23, Part 3, Chapter 7.112, the narrow existing-installation derogation in Part 8 and the dossier requirements in Part 9. Reviewed against V06 on 29 August 2026.",{"title":135,"searchDepth":372,"depth":372,"links":373},2,[374,375,376,377,378,379,380,387,388,389,390,391,392,393,394],{"id":25,"depth":372,"text":26},{"id":60,"depth":372,"text":61},{"id":93,"depth":372,"text":94},{"id":120,"depth":372,"text":121},{"id":144,"depth":372,"text":145},{"id":176,"depth":372,"text":177},{"id":209,"depth":372,"text":210,"children":381},[382,384,385,386],{"id":214,"depth":383,"text":215},3,{"id":221,"depth":383,"text":222},{"id":228,"depth":383,"text":229},{"id":235,"depth":383,"text":236},{"id":242,"depth":372,"text":243},{"id":272,"depth":372,"text":273},{"id":296,"depth":372,"text":297},{"id":306,"depth":372,"text":307},{"id":319,"depth":372,"text":320},{"id":329,"depth":372,"text":330},{"id":348,"depth":372,"text":349},{"id":360,"depth":372,"text":361},"tutorial","2026-08-29","Locate PV modules, inverter, fixed isolators, distribution boards and cable routes on the situation plan using the same references as the single-line diagram.","md","en",{},true,"\u002Fblog\u002Fpv-situation-plan.en","10 min",12,{"title":5,"description":397},"solar-pv-situation-plan","blog\u002Fpv-situation-plan.en",[409,410,411,412,413,414,415],"Solar PV","Situation plan","PV modules","Inverter","AREI","Cable route","Belgium","14hraDbdna7RayPwnHWqET2nD7xmRylYG7BYzoqZROs",[418,810,1055,1443],{"id":419,"title":420,"articleId":6,"body":421,"category":395,"date":396,"description":795,"extension":398,"lastUpdated":396,"locale":796,"meta":797,"navigation":401,"path":798,"publishDate":396,"readTime":403,"refreshInterval":404,"seo":799,"slug":800,"stem":801,"tags":802,"__hash__":809},"blog\u002Fblog\u002Fpv-situation-plan.de.md","PV-Anlage im Situationsplan zeichnen: Module, Wechselrichter und Leitungswege",{"type":8,"value":422,"toc":773},[423,430,433,437,440,463,466,470,473,490,498,502,505,522,525,529,532,535,541,544,548,551,568,576,580,583,586,600,608,612,616,619,623,626,630,633,637,640,644,647,667,670,674,677,697,701,704,707,711,714,717,720,724,727,730,734,737,740,743,750,754,761,765],[11,424,425,426,429],{},"Beim Photovoltaikprojekt konzentriert sich die Dokumentation oft auf das Eindrahtschema. Dort stehen Strings, Wechselrichter, Schutzgeräte und Anschluss am Verteiler. Der Situationsplan erfüllt eine andere Aufgabe: Er zeigt die ",[15,427,428],{},"räumliche Lage"," der festen elektrischen Komponenten. Für spätere Wartung, Umbau und Prüfung muss erkennbar sein, auf welcher Dachfläche die Module liegen, wo der Wechselrichter montiert ist und wie die feste Anlage mit dem Verteiler verbunden ist.",[11,431,432],{},"Ein Situationsplan ist weder ein Dachstatikplan noch ein vollständiger DC-Schaltplan. Er ergänzt das Eindrahtschema, ohne dessen elektrische Details zu duplizieren.",[23,434,436],{"id":435},"grundlage-aktueller-gebäudeplan-und-ist-aufnahme","Grundlage: aktueller Gebäudeplan und Ist-Aufnahme",[11,438,439],{},"Verwenden Sie einen maßstäblich nachvollziehbaren Grundriss oder eine eindeutige Gebäudezeichnung mit Geschossen, Räumen, Zugängen und wichtigen Außenflächen. Für Dachanlagen kann eine Dachaufsicht oder ergänzende Ansicht sinnvoll sein. Prüfen Sie vor Ort:",[31,441,442,445,448,451,454,457,460],{},[34,443,444],{},"genaue Modulfelder und ihre Orientierung;",[34,446,447],{},"Lage des Wechselrichters oder der Mikro-Wechselrichter;",[34,449,450],{},"feste DC- und AC-Trennstellen, sofern vorhanden;",[34,452,453],{},"Haupt- und Unterverteiler, an den die PV-Anlage angeschlossen ist;",[34,455,456],{},"feste Kabeldurchführungen und wesentliche Leitungswege;",[34,458,459],{},"Zähler- oder Messschrank, wenn er für die Zuordnung nötig ist;",[34,461,462],{},"Batteriespeicher, Backup-Umschaltung oder Generatoranschluss, falls Teil des Systems.",[11,464,465],{},"Übernehmen Sie nicht ungeprüft den Angebotsplan. Dachbelegung, Wechselrichterstandort und Leitungsführung ändern sich häufig während der Montage.",[23,467,469],{"id":468},"was-auf-dem-dach-erscheinen-sollte","Was auf dem Dach erscheinen sollte",[11,471,472],{},"Zeigen Sie das Modulfeld so, dass seine Lage eindeutig ist. Abhängig von Größe und Planmaßstab kann das bedeuten:",[31,474,475,478,481,484,487],{},[34,476,477],{},"einzelne Module oder klar abgegrenzte Modulgruppen;",[34,479,480],{},"Zuordnung zu Dachfläche, Nebengebäude, Fassade oder Freifläche;",[34,482,483],{},"verständliche Kennzeichnung der Strings, wenn sie zur Verbindung mit dem Eindrahtschema nötig ist;",[34,485,486],{},"Lage von fest installierten DC-Sammel- oder Schaltkästen;",[34,488,489],{},"relevante Gebäudekanten, Dachzugänge oder Brandabschnitte, soweit sie die elektrische Lage erklären.",[11,491,492,493,497],{},"Der Situationsplan muss nicht jede Steckverbindung unter einem Modul darstellen. Stringverschaltung, Polarität, Leitertyp und elektrische Schutzkette gehören in erster Linie in das ",[86,494,496],{"href":495},"\u002Fde\u002Fblog\u002Fpv-anlage-schema","PV-Eindrahtschema",". Verwenden Sie auf beiden Dokumenten dieselben String- und Gerätebezeichnungen.",[23,499,501],{"id":500},"wechselrichter-eindeutig-lokalisieren","Wechselrichter eindeutig lokalisieren",[11,503,504],{},"Markieren Sie den tatsächlichen Montageort und unterscheiden Sie gegebenenfalls:",[31,506,507,510,513,516,519],{},[34,508,509],{},"zentralen Stringwechselrichter;",[34,511,512],{},"mehrere Wechselrichter;",[34,514,515],{},"Mikro-Wechselrichter an oder unter den Modulen;",[34,517,518],{},"Hybridwechselrichter und separaten Batteriespeicher;",[34,520,521],{},"zugehörige feste Trenn- oder Schaltvorrichtungen.",[11,523,524],{},"Eine bloße Beschriftung „Garage“ genügt bei einem großen Raum nicht immer. Das Symbol sollte an der Wand oder Position liegen, an der das Gerät erreichbar ist. Bei außen montierten Geräten ist die Fassadenseite eindeutig anzugeben.",[23,526,528],{"id":527},"leitungswege-lesbar-statt-dekorativ-zeichnen","Leitungswege lesbar statt dekorativ zeichnen",[11,530,531],{},"Ein hilfreicher Plan zeigt, wie die feste elektrische Verbindung räumlich vom Modulbereich zum Wechselrichter und weiter zum Verteiler verläuft. Zeichnen Sie insbesondere Gebäudedurchführungen, Steigzonen, Schächte oder Wechsel zwischen Geschossen, wenn sie später nicht sichtbar sind.",[11,533,534],{},"Unterscheiden Sie DC- und AC-Weg durch definierte Linienarten oder Beschriftungen. Farben allein sind ungeeignet, weil Ausdrucke schwarz-weiß sein können. Eine Legende kann beispielsweise festlegen:",[129,536,539],{"className":537,"code":538,"language":134,"meta":135},[132],"PV-DC  ─ ─ ─  Gleichstromleitung vom Modulfeld\nPV-AC  ─────  Wechselstromleitung zum Verteiler\nDAT    ·····  feste Mess-\u002FKommunikationsleitung\n",[137,540,538],{"__ignoreMap":135},[11,542,543],{},"Die Linien sind Dokumentationssymbole, keine Aussage über Verlegeart oder Kabeltyp. Diese Angaben stehen am zugehörigen Stromkreis im Eindrahtschema.",[23,545,547],{"id":546},"symbole-und-eigene-legende","Symbole und eigene Legende",[11,549,550],{},"Die Symboltabelle 2.23 von AREI Buch 1 V06 ist nicht erschöpfend. Ein eindeutiges projektspezifisches Zeichen für Modulfeld, Wechselrichter oder DC-Trennstelle kann verwendet werden, wenn die Legende es erklärt. Achten Sie auf:",[31,552,553,556,559,562,565],{},[34,554,555],{},"ausreichende Größe im PDF-Ausdruck;",[34,557,558],{},"unterschiedliche Form oder Zusatztext für Wechselrichter und Speicher;",[34,560,561],{},"gleichbleibende Referenzen auf allen Seiten;",[34,563,564],{},"keine rein farbliche Unterscheidung;",[34,566,567],{},"klare Abgrenzung zwischen elektrischem Betriebsmittel und baulichem Objekt.",[11,569,570,571,575],{},"Die ",[86,572,574],{"href":573},"\u002Fde\u002Fblog\u002Farei-elektrosymbole-uebersicht","AREI-Symbolübersicht"," beschreibt die Legendenregel und technische Zusatzangaben ausführlicher.",[23,577,579],{"id":578},"stromkreisreferenzen-verbinden-beide-pläne","Stromkreisreferenzen verbinden beide Pläne",[11,581,582],{},"Teil 3 von AREI Buch 1 V06 verlangt für Situationsplan und Eindrahtschema eine gemeinsame Referenzlogik. Der AC-Abgang des Wechselrichters muss daher im Situationsplan dieselbe Stromkreiskennung tragen wie im Eindrahtschema. String- oder Gerätekennungen sollten ebenfalls identisch bleiben, wenn sie auf beiden Plänen verwendet werden.",[11,584,585],{},"Ein praktischer Abgleich läuft in beide Richtungen:",[185,587,588,591,594,597],{},[34,589,590],{},"Jedes feste PV-Element im Situationsplan wird im Eindrahtschema oder in dessen Legende gefunden.",[34,592,593],{},"Jeder räumlich relevante PV-Baustein des Eindrahtschemas erhält eine auffindbare Position.",[34,595,596],{},"Verteiler- und Geschossbezeichnungen stimmen überein.",[34,598,599],{},"Versionsstand, Datum und Anlagenadresse sind auf beiden Dokumenten gleich.",[11,601,602,603,607],{},"Mehr zur Aufgabenteilung steht unter ",[86,604,606],{"href":605},"\u002Fde\u002Fblog\u002Feindrahtschema-vs-situationsplan","Eindrahtschema versus Situationsplan",".",[23,609,611],{"id":610},"besondere-konfigurationen","Besondere Konfigurationen",[212,613,615],{"id":614},"mikro-wechselrichter","Mikro-Wechselrichter",[11,617,618],{},"Bei vielen baugleichen Geräten kann eine gruppierte Darstellung mit Anzahl, Typ und eindeutiger Zuordnung lesbarer sein als überlappende Symbole. Der elektrische Parallelanschluss bleibt im Eindrahtschema sichtbar.",[212,620,622],{"id":621},"batteriespeicher","Batteriespeicher",[11,624,625],{},"Markieren Sie Speicher, Wechselrichter, feste Trennstellen und gegebenenfalls Backup-Verteiler räumlich. Ein Speicher ist kein PV-Modul und braucht ein eigenes Symbol. Sicherheitsabstände oder Aufstellanforderungen stammen aus Planung und Herstellerunterlagen; der Plan dokumentiert die ausgeführte Lage.",[212,627,629],{"id":628},"nebengebäude-oder-freifläche","Nebengebäude oder Freifläche",[11,631,632],{},"Zeigen Sie die Verbindung zwischen Gebäuden, den Eintrittspunkt und beteiligte Unterverteiler. Ein Pfeil „zum Haus“ ohne eindeutiges Ziel erschwert spätere Arbeiten.",[212,634,636],{"id":635},"bestehende-anlagen","Bestehende Anlagen",[11,638,639],{},"Teil 8 enthält für bestimmte bestehende hauswirtschaftliche PV-Anlagen bis 10 kVA eine Abweichung, nach der eine schriftliche Beschreibung, gegebenenfalls mit Fotos, ausreichen kann. Diese Bestandsregel ist kein allgemeiner Ersatz für einen aktuellen Situationsplan bei Neubau oder wesentlicher Änderung. Klären Sie den konkreten Anwendungsfall fachlich.",[23,641,643],{"id":642},"dossier-und-fotodokumentation","Dossier und Fotodokumentation",[11,645,646],{},"Fotos ergänzen den Situationsplan sinnvoll, besonders bei verdeckten Leitungswegen, Dachbereichen und Gerätebeschriftungen. Sie ersetzen nicht automatisch die strukturierten elektrischen Pläne. Legen Sie mindestens ab:",[31,648,649,652,655,658,661,664],{},[34,650,651],{},"finalen Situationsplan und Eindrahtschema;",[34,653,654],{},"Modul- und Wechselrichterdaten;",[34,656,657],{},"verfügbare String- und Messdaten;",[34,659,660],{},"Herstelleranleitungen und Konformitätsunterlagen;",[34,662,663],{},"Prüfberichte einer zugelassenen Stelle;",[34,665,666],{},"spätere Änderungen mit neuem Versionsstand.",[11,668,669],{},"Der Eigentümer sollte das Dossier verfügbar halten und bei Änderungen aktualisieren lassen.",[23,671,673],{"id":672},"abschlusscheck","Abschlusscheck",[11,675,676],{},"Kontrollieren Sie vor dem PDF-Export:",[31,678,679,682,685,688,691,694],{},[34,680,681],{},"Sind alle Modulfelder, Wechselrichter und festen Zusatzgeräte am richtigen Ort?",[34,683,684],{},"Sind DC- und AC-Weg unterscheidbar und in der Legende erklärt?",[34,686,687],{},"Stimmen Stromkreis-, String- und Verteilerreferenzen mit dem Eindrahtschema überein?",[34,689,690],{},"Bleiben Symbole und Texte im geplanten Druckformat lesbar?",[34,692,693],{},"Entspricht der Plan dem Ist-Zustand statt nur dem ursprünglichen Angebot?",[34,695,696],{},"Tragen beide Pläne dieselbe Adresse, Version und dasselbe Datum?",[23,698,700],{"id":699},"mehrseitige-pläne-eindeutig-organisieren","Mehrseitige Pläne eindeutig organisieren",[11,702,703],{},"Passt Dach, Technikraum und Verteilung nicht lesbar auf eine Seite, teilen Sie den Plan in beschriftete Ansichten. Ein Übersichtsblatt zeigt die Beziehung zwischen Gebäude, Dachflächen und Verteilern; Detailblätter vergrößern Modulfelder oder Technikzonen. Verwenden Sie Blattnummern und eindeutige Fortsetzungsverweise wie „PV-DC weiter auf Blatt S2“.",[11,705,706],{},"Jede Teilansicht braucht genug Orientierung: Geschoss, Raumname, Nordrichtung oder klar erkennbare Gebäudeseite. Kopieren Sie nicht dieselbe Gerätekennung auf mehrere Positionen, sofern es nicht tatsächlich mehrere Geräte gibt. Eine Referenztabelle kann Symbol, Geräte-ID, Stromkreis und Blatt zusammenführen. So bleibt auch ein umfangreicher Plan prüfbar, ohne dass kleine Symbole oder lange Leitungswege die Lesbarkeit zerstören.",[23,708,710],{"id":709},"praxisbeispiel-zwei-dachflächen-und-ein-wechselrichter-im-technikraum","Praxisbeispiel: zwei Dachflächen und ein Wechselrichter im Technikraum",[11,712,713],{},"Nehmen Sie ein Haus mit Modulen auf Ost- und Westdach, zwei DC-Strings und einem Wechselrichter im Technikraum an. Der Situationsplan zeigt zwei getrennte Modulfelder mit eigener Kennung, nicht ein Symbol in der Dachmitte. Markieren Sie, welche Stringreferenz zu welcher Fläche gehört und an welcher Stelle die DC-Leitungen in das Gebäude eintreten. Der gemeinsame Leitungsweg zum Technikraum wird nur dann als ein Trassenabschnitt dargestellt, wenn dies der realen Ausführung entspricht.",[11,715,716],{},"Im Technikraum erhält der Wechselrichter eine eindeutige Gerätekennung und seine reale Wandposition. Liegen DC-Trennstelle, Überspannungsschutz oder weitere feste Einrichtungen extern, werden auch sie lokalisiert und mit dem Eindrahtschema verknüpft. Integrierte Funktionen bleiben am Gerät dokumentiert und werden nicht als separate Kästen erfunden. Der AC-Weg endet beim richtigen Verteiler und Stromkreis; eine Linie zum nächstgelegenen Raum wäre fachlich wertlos.",[11,718,719],{},"Prüfen Sie die Orientierung des Dachdetails. Dachseite, Traufe, First, Nordrichtung und erkennbare Gebäudekanten sollten reichen, um Feld und Eintrittspunkt vor Ort wiederzufinden. Der Plan muss keine Montagezeichnung mit jedem Haken sein. Er sollte aber Unterschiede abbilden, die für elektrische Zuordnung, sichere Arbeit oder spätere Fehlersuche relevant sind.",[23,721,723],{"id":722},"aufnahme-bei-verdeckten-oder-unzugänglichen-wegen","Aufnahme bei verdeckten oder unzugänglichen Wegen",[11,725,726],{},"Erfinden Sie keine geometrisch exakte Route, wenn der Bestand sie nicht erkennen lässt. Kennzeichnen Sie einen Abschnitt als verdeckt oder nur anhand vorhandener Unterlagen übernommen und bewahren Sie die Quelle der Angabe auf. Fotos vom Eintrittspunkt, Beschriftungen, Durchführungen und Technikraum helfen, die Unsicherheit einzugrenzen. Eine gestrichelte Linie erhält nur dann diese Bedeutung, wenn die Legende sie definiert.",[11,728,729],{},"Unterscheiden Sie drei Wissensstände: vor Ort gesehen, durch verlässliche technische Unterlagen belegt und noch zu klären. Offene Punkte gehören in eine Arbeitsliste, nicht als scheinbar sichere Linie in die Endfassung. Vor der Kontrolle sollte die verantwortliche Fachkraft entscheiden, ob weitere Aufnahme oder Freilegung erforderlich ist.",[23,731,733],{"id":732},"änderungen-am-dach-systematisch-nachführen","Änderungen am Dach systematisch nachführen",[11,735,736],{},"Nach Modultausch, zusätzlichem Feld oder neuem Wechselrichter prüfen Sie mehr als die sichtbare Dachfläche. Aktualisieren Sie Feld- und Stringkennung, Leitungsweg, Eintrittspunkt, Geräteposition, DC- und AC-Referenzen sowie technische Unterlagen. Werden Module nur innerhalb eines bestehenden Strings ersetzt, dokumentieren Sie trotzdem die tatsächlich installierte Anzahl und Nennleistung in der dafür vorgesehenen Akte. Werden Strings neu verschaltet, müssen Eindrahtschema und Situationsplan denselben neuen Stand tragen.",[11,738,739],{},"Bewahren Sie die ersetzte Version mit Datum getrennt auf. So lässt sich später erkennen, ob ein Foto oder Prüfbericht zum alten oder aktuellen Aufbau gehört. Eine Cloud-Ansicht des Wechselrichters kann Ertragsdaten liefern, ersetzt aber weder räumliche Aufnahme noch den Planstand.",[11,741,742],{},"Kontrollieren Sie die Endfassung bei der vorgesehenen Druckgröße. Ein neues Feld darf vorhandene Referenzen nicht überdecken, und eine Leitung darf nicht wie eine Gebäudekante wirken. Verschieben Sie Detailrahmen kontrolliert, aktualisieren Sie den Blattindex und prüfen Sie jeden Fortsetzungsverweis. Damit bleibt auch eine erweiterte Dachanlage ohne Zoomen oder Zugriff auf die Editor-Datei vor Ort verständlich.",[11,744,570,745,749],{},[86,746,748],{"href":341,"rel":747},[343],"amtliche FÖD-Seite zu Kontrollen von Wohnanlagen"," nennt Quellen ausdrücklich als Inhalte von Eindrahtschema und Situationsplan sowie die PV-Technikunterlagen als Teil des Dossiers. Die notwendige Detailtiefe richtet sich nach Anlage und amtlichem Buch 1 V06, nicht nach einer pauschalen Dachvorlage.",[23,751,753],{"id":752},"situationsplan-mit-planelec-erstellen","Situationsplan mit PlanElec erstellen",[11,755,756,757,760],{},"Mit ",[86,758,356],{"href":759},"\u002Fde\u002F"," können Sie PV-Komponenten im Situationsplan platzieren, die elektrische Struktur im Eindrahtschema erfassen und beide Dokumente als PDF exportieren. Die Software übernimmt nur die eingegebenen Projektdaten. Der orientierende Selbstcheck kann unterstützte Angaben auf Auffälligkeiten prüfen, ersetzt aber weder Vor-Ort-Abgleich noch zugelassene Prüfung und bestätigt keine AREI-Konformität.",[23,762,764],{"id":763},"quellenstand","Quellenstand",[11,766,767,768,772],{},"Grundlage ist die amtliche Veröffentlichung von ",[86,769,771],{"href":367,"rel":770},[343],"AREI\u002FRGIE Buch 1",", insbesondere Teil 2 Tabelle 2.23, Teil 3 zu Inhalt und Referenzen, Kapitel 7.112, Teil 8 für eng begrenzte Bestandsabweichungen und Teil 9 zum Dossier. Geprüfter Stand: V06, 29.08.2026.",{"title":135,"searchDepth":372,"depth":372,"links":774},[775,776,777,778,779,780,781,787,788,789,790,791,792,793,794],{"id":435,"depth":372,"text":436},{"id":468,"depth":372,"text":469},{"id":500,"depth":372,"text":501},{"id":527,"depth":372,"text":528},{"id":546,"depth":372,"text":547},{"id":578,"depth":372,"text":579},{"id":610,"depth":372,"text":611,"children":782},[783,784,785,786],{"id":614,"depth":383,"text":615},{"id":621,"depth":383,"text":622},{"id":628,"depth":383,"text":629},{"id":635,"depth":383,"text":636},{"id":642,"depth":372,"text":643},{"id":672,"depth":372,"text":673},{"id":699,"depth":372,"text":700},{"id":709,"depth":372,"text":710},{"id":722,"depth":372,"text":723},{"id":732,"depth":372,"text":733},{"id":752,"depth":372,"text":753},{"id":763,"depth":372,"text":764},"So verorten Sie PV-Module, Wechselrichter, feste Trennstellen, Verteiler und Leitungswege im Situationsplan und halten ihn mit dem Eindrahtschema synchron.","de",{},"\u002Fblog\u002Fpv-situation-plan.de",{"title":420,"description":795},"pv-anlage-situationsplan","blog\u002Fpv-situation-plan.de",[803,804,805,806,413,807,808],"Photovoltaik","Situationsplan","PV-Module","Wechselrichter","Leitungsweg","Belgien","ZunJ4oSY51mEcYueodJqwY8v9F6s1LComI_n-Cl68c0",{"id":4,"title":5,"articleId":6,"body":811,"category":395,"date":396,"description":397,"extension":398,"lastUpdated":396,"locale":399,"meta":1052,"navigation":401,"path":402,"publishDate":396,"readTime":403,"refreshInterval":404,"seo":1053,"slug":406,"stem":407,"tags":1054,"__hash__":416},{"type":8,"value":812,"toc":1030},[813,817,819,821,823,839,841,843,845,857,861,863,865,877,879,881,883,885,890,892,894,896,908,912,914,916,918,928,932,934,936,938,940,942,944,946,948,950,952,954,968,970,972,986,988,990,992,994,996,998,1000,1002,1004,1006,1008,1010,1012,1017,1019,1023,1025],[11,814,13,815,18],{},[15,816,17],{},[11,818,21],{},[23,820,26],{"id":25},[11,822,29],{},[31,824,825,827,829,831,833,835,837],{},[34,826,36],{},[34,828,39],{},[34,830,42],{},[34,832,45],{},[34,834,48],{},[34,836,51],{},[34,838,54],{},[11,840,57],{},[23,842,61],{"id":60},[11,844,64],{},[31,846,847,849,851,853,855],{},[34,848,69],{},[34,850,72],{},[34,852,75],{},[34,854,78],{},[34,856,81],{},[11,858,84,859,90],{},[86,860,89],{"href":88},[23,862,94],{"id":93},[11,864,97],{},[31,866,867,869,871,873,875],{},[34,868,102],{},[34,870,105],{},[34,872,108],{},[34,874,111],{},[34,876,114],{},[11,878,117],{},[23,880,121],{"id":120},[11,882,124],{},[11,884,127],{},[129,886,888],{"className":887,"code":133,"language":134,"meta":135},[132],[137,889,133],{"__ignoreMap":135},[11,891,141],{},[23,893,145],{"id":144},[11,895,148],{},[31,897,898,900,902,904,906],{},[34,899,153],{},[34,901,156],{},[34,903,159],{},[34,905,162],{},[34,907,165],{},[11,909,168,910,173],{},[86,911,172],{"href":171},[23,913,177],{"id":176},[11,915,180],{},[11,917,183],{},[185,919,920,922,924,926],{},[34,921,189],{},[34,923,192],{},[34,925,195],{},[34,927,198],{},[11,929,201,930,206],{},[86,931,205],{"href":204},[23,933,210],{"id":209},[212,935,215],{"id":214},[11,937,218],{},[212,939,222],{"id":221},[11,941,225],{},[212,943,229],{"id":228},[11,945,232],{},[212,947,236],{"id":235},[11,949,239],{},[23,951,243],{"id":242},[11,953,246],{},[31,955,956,958,960,962,964,966],{},[34,957,251],{},[34,959,254],{},[34,961,257],{},[34,963,260],{},[34,965,263],{},[34,967,266],{},[11,969,269],{},[23,971,273],{"id":272},[31,973,974,976,978,980,982,984],{},[34,975,278],{},[34,977,281],{},[34,979,284],{},[34,981,287],{},[34,983,290],{},[34,985,293],{},[23,987,297],{"id":296},[11,989,300],{},[11,991,303],{},[23,993,307],{"id":306},[11,995,310],{},[11,997,313],{},[11,999,316],{},[23,1001,320],{"id":319},[11,1003,323],{},[11,1005,326],{},[23,1007,330],{"id":329},[11,1009,333],{},[11,1011,336],{},[11,1013,168,1014,345],{},[86,1015,344],{"href":341,"rel":1016},[343],[23,1018,349],{"id":348},[11,1020,352,1021,357],{},[86,1022,356],{"href":355},[23,1024,361],{"id":360},[11,1026,364,1027,370],{},[86,1028,369],{"href":367,"rel":1029},[343],{"title":135,"searchDepth":372,"depth":372,"links":1031},[1032,1033,1034,1035,1036,1037,1038,1044,1045,1046,1047,1048,1049,1050,1051],{"id":25,"depth":372,"text":26},{"id":60,"depth":372,"text":61},{"id":93,"depth":372,"text":94},{"id":120,"depth":372,"text":121},{"id":144,"depth":372,"text":145},{"id":176,"depth":372,"text":177},{"id":209,"depth":372,"text":210,"children":1039},[1040,1041,1042,1043],{"id":214,"depth":383,"text":215},{"id":221,"depth":383,"text":222},{"id":228,"depth":383,"text":229},{"id":235,"depth":383,"text":236},{"id":242,"depth":372,"text":243},{"id":272,"depth":372,"text":273},{"id":296,"depth":372,"text":297},{"id":306,"depth":372,"text":307},{"id":319,"depth":372,"text":320},{"id":329,"depth":372,"text":330},{"id":348,"depth":372,"text":349},{"id":360,"depth":372,"text":361},{},{"title":5,"description":397},[409,410,411,412,413,414,415],{"id":1056,"title":1057,"articleId":6,"body":1058,"category":395,"date":396,"description":1427,"extension":398,"lastUpdated":396,"locale":1428,"meta":1429,"navigation":401,"path":1430,"publishDate":396,"readTime":403,"refreshInterval":404,"seo":1431,"slug":1432,"stem":1433,"tags":1434,"__hash__":1442},"blog\u002Fblog\u002Fpv-situation-plan.fr.md","Photovoltaïque sur le plan de situation : modules, onduleur et cheminements",{"type":8,"value":1059,"toc":1405},[1060,1067,1070,1074,1077,1100,1103,1107,1110,1127,1135,1139,1142,1159,1162,1166,1169,1172,1178,1181,1185,1188,1205,1213,1217,1220,1223,1237,1245,1249,1253,1256,1260,1263,1267,1270,1274,1277,1281,1284,1304,1307,1311,1331,1335,1338,1341,1345,1348,1351,1354,1358,1361,1364,1368,1371,1374,1382,1386,1393,1397],[11,1061,1062,1063,1066],{},"Dans un projet photovoltaïque, le schéma unifilaire retient souvent toute l’attention : chaînes, onduleur, protections et raccordement y apparaissent. Le plan de situation répond à une autre question : ",[15,1064,1065],{},"où se trouvent"," les éléments électriques fixes ? Pour une maintenance, une transformation ou un contrôle ultérieur, il faut retrouver les champs de modules, l’onduleur et le parcours jusqu’au tableau.",[11,1068,1069],{},"Ce document n’est ni une étude de stabilité de toiture, ni un second schéma DC complet. Il complète l’unifilaire sans recopier toute sa logique électrique.",[23,1071,1073],{"id":1072},"partir-dun-relevé-as-built","Partir d’un relevé as-built",[11,1075,1076],{},"Utilisez un plan reconnaissable avec niveaux, locaux, accès et zones extérieures importantes. Une vue de toiture ou de façade peut être nécessaire. Relevez sur place :",[31,1078,1079,1082,1085,1088,1091,1094,1097],{},[34,1080,1081],{},"champs de modules et orientation réelle ;",[34,1083,1084],{},"position des onduleurs centraux ou micro-onduleurs ;",[34,1086,1087],{},"sectionnements DC et AC fixes lorsqu’ils existent ;",[34,1089,1090],{},"tableau principal ou secondaire raccordé ;",[34,1092,1093],{},"traversées et cheminements fixes importants ;",[34,1095,1096],{},"armoire de comptage si elle clarifie la liaison ;",[34,1098,1099],{},"batterie, commutation de secours ou autre source intégrée.",[11,1101,1102],{},"Ne reprenez pas le plan d’offre sans contrôle. L’implantation des modules, la place de l’onduleur et le passage des câbles peuvent changer pendant les travaux.",[23,1104,1106],{"id":1105},"représenter-la-zone-de-modules","Représenter la zone de modules",[11,1108,1109],{},"Le champ doit être localisable sans ambiguïté. Selon l’échelle, indiquez :",[31,1111,1112,1115,1118,1121,1124],{},[34,1113,1114],{},"modules individuels ou groupes clairement délimités ;",[34,1116,1117],{},"versant, annexe, façade ou zone au sol concernée ;",[34,1119,1120],{},"repères de chaînes lorsqu’ils assurent la liaison avec l’unifilaire ;",[34,1122,1123],{},"coffrets DC fixes de jonction ou de coupure ;",[34,1125,1126],{},"bords, accès ou compartiments utiles pour comprendre l’emplacement électrique.",[11,1128,1129,1130,1134],{},"Il n’est pas nécessaire de dessiner chaque connecteur sous chaque module. La connexion des chaînes, la polarité, les conducteurs et la protection sont détaillés surtout dans le ",[86,1131,1133],{"href":1132},"\u002Ffr\u002Fblog\u002Fpanneaux-solaires-schema","schéma unifilaire photovoltaïque",". Les repères de chaîne et d’équipement doivent être identiques.",[23,1136,1138],{"id":1137},"localiser-précisément-londuleur","Localiser précisément l’onduleur",[11,1140,1141],{},"Placez le symbole au lieu réel et distinguez si nécessaire :",[31,1143,1144,1147,1150,1153,1156],{},[34,1145,1146],{},"onduleur central de chaînes ;",[34,1148,1149],{},"plusieurs onduleurs ;",[34,1151,1152],{},"micro-onduleurs près des modules ;",[34,1154,1155],{},"onduleur hybride et batterie séparée ;",[34,1157,1158],{},"dispositifs fixes de coupure associés.",[11,1160,1161],{},"La seule mention « garage » peut être trop vague dans un grand local. Montrez le mur ou la zone technique. Pour un appareil extérieur, identifiez la façade.",[23,1163,1165],{"id":1164},"dessiner-les-cheminements-utiles","Dessiner les cheminements utiles",[11,1167,1168],{},"Le plan doit permettre de suivre spatialement la liaison fixe du champ à l’onduleur, puis au tableau. Montrez les traversées de bâtiment, gaines, colonnes montantes et changements de niveau qui seront cachés après finition.",[11,1170,1171],{},"Différenciez le trajet DC du trajet AC par un type de ligne ou un texte, pas par la couleur seule. Le PDF imprimé en noir et blanc doit rester lisible :",[129,1173,1176],{"className":1174,"code":1175,"language":134,"meta":135},[132],"PV-DC  ─ ─ ─  cheminement continu depuis les modules\nPV-AC  ─────  cheminement alternatif vers le tableau\nDATA   ·····  liaison fixe de mesure ou communication\n",[137,1177,1175],{"__ignoreMap":135},[11,1179,1180],{},"Définissez ces conventions dans la légende. Elles ne précisent pas le type de câble ou le mode de pose, qui restent indiqués sur l’unifilaire.",[23,1182,1184],{"id":1183},"symboles-et-légende-de-projet","Symboles et légende de projet",[11,1186,1187],{},"Le tableau 2.23 du RGIE Livre 1 V06 n’est pas exhaustif. Un signe propre au projet pour le champ PV, l’onduleur ou un sectionneur DC est acceptable s’il est non ambigu et défini dans la légende. Vérifiez :",[31,1189,1190,1193,1196,1199,1202],{},[34,1191,1192],{},"taille suffisante dans le PDF final ;",[34,1194,1195],{},"distinction de forme ou de texte entre onduleur et stockage ;",[34,1197,1198],{},"mêmes références sur toutes les pages ;",[34,1200,1201],{},"information qui ne dépend pas seulement de la couleur ;",[34,1203,1204],{},"séparation claire entre appareil électrique et élément du bâtiment.",[11,1206,1207,1208,1212],{},"La page ",[86,1209,1211],{"href":1210},"\u002Ffr\u002Fblog\u002Fsymboles-electriques-rgie","symboles électriques du RGIE"," explique cette règle de légende.",[23,1214,1216],{"id":1215},"conserver-les-références-communes","Conserver les références communes",[11,1218,1219],{},"La partie 3 du RGIE Livre 1 V06 relie plan de situation et unifilaire par les références de circuits. Le départ AC de l’onduleur porte donc le même repère sur les deux documents. Les références de chaînes ou d’appareils utilisées des deux côtés restent elles aussi identiques.",[11,1221,1222],{},"Effectuez un contrôle croisé :",[185,1224,1225,1228,1231,1234],{},[34,1226,1227],{},"Chaque élément PV fixe du plan de situation existe sur l’unifilaire ou dans sa légende.",[34,1229,1230],{},"Chaque élément spatialement pertinent de l’unifilaire possède une position retrouvable.",[34,1232,1233],{},"Les noms de tableaux et de niveaux concordent.",[34,1235,1236],{},"Adresse, date et indice de version sont identiques.",[11,1238,1239,1240,1244],{},"Le guide ",[86,1241,1243],{"href":1242},"\u002Ffr\u002Fblog\u002Fschema-unifilaire-vs-plan-situation","schéma unifilaire ou plan de situation"," détaille leur complémentarité.",[23,1246,1248],{"id":1247},"configurations-particulières","Configurations particulières",[212,1250,1252],{"id":1251},"micro-onduleurs","Micro-onduleurs",[11,1254,1255],{},"Pour de nombreux appareils identiques, un groupe avec quantité, type et modules associés peut être plus lisible que des symboles superposés. Le parallélisme électrique reste décrit sur l’unifilaire.",[212,1257,1259],{"id":1258},"batterie-domestique","Batterie domestique",[11,1261,1262],{},"Localisez batterie, onduleur, coupures fixes et éventuel tableau de secours. La batterie reçoit son propre symbole. Les contraintes d’implantation proviennent de l’étude et du constructeur ; le plan consigne la position exécutée.",[212,1264,1266],{"id":1265},"annexe-ou-installation-au-sol","Annexe ou installation au sol",[11,1268,1269],{},"Montrez le trajet entre bâtiments, le point d’entrée et les tableaux secondaires. Une flèche « vers maison » sans destination précise n’aide pas une intervention future.",[212,1271,1273],{"id":1272},"installation-existante","Installation existante",[11,1275,1276],{},"La partie 8 prévoit, pour certaines installations photovoltaïques domestiques existantes jusqu’à 10 kVA, une dérogation limitée permettant une description écrite éventuellement accompagnée de photos. Cette règle de l’existant ne doit pas être généralisée à une construction neuve ou à une modification importante. Faites qualifier le cas concret.",[23,1278,1280],{"id":1279},"dossier-et-photographies","Dossier et photographies",[11,1282,1283],{},"Les photos complètent utilement le plan pour les parcours cachés, la toiture et les plaques signalétiques, mais ne remplacent pas automatiquement les plans structurés. Conservez :",[31,1285,1286,1289,1292,1295,1298,1301],{},[34,1287,1288],{},"plan de situation et unifilaire finaux ;",[34,1290,1291],{},"données des modules et onduleurs ;",[34,1293,1294],{},"informations de chaînes et mesures disponibles ;",[34,1296,1297],{},"notices et déclarations des équipements ;",[34,1299,1300],{},"rapports de l’organisme agréé ;",[34,1302,1303],{},"modifications ultérieures avec nouvel indice.",[11,1305,1306],{},"Le propriétaire garde le dossier disponible et le fait mettre à jour lors des transformations.",[23,1308,1310],{"id":1309},"contrôle-avant-export","Contrôle avant export",[31,1312,1313,1316,1319,1322,1325,1328],{},[34,1314,1315],{},"Les champs, onduleurs et appareils fixes sont-ils à leur position réelle ?",[34,1317,1318],{},"Les trajets DC et AC sont-ils distingués et légendés ?",[34,1320,1321],{},"Les repères de circuits, chaînes et tableaux concordent-ils avec l’unifilaire ?",[34,1323,1324],{},"Symboles et textes restent-ils lisibles au format d’impression ?",[34,1326,1327],{},"Le document correspond-il à l’as-built plutôt qu’à l’offre initiale ?",[34,1329,1330],{},"Adresse, date et version sont-elles identiques sur les deux plans ?",[23,1332,1334],{"id":1333},"organiser-un-plan-sur-plusieurs-feuilles","Organiser un plan sur plusieurs feuilles",[11,1336,1337],{},"Si toiture, local technique et tableaux ne tiennent pas lisiblement sur une page, créez des vues nommées. Une feuille générale relie bâtiment, versants et tableaux ; des détails agrandissent les champs et zones techniques. Numérotez les feuilles et utilisez des renvois explicites, par exemple « PV-DC suite feuille S2 ».",[11,1339,1340],{},"Chaque extrait conserve des repères d’orientation : niveau, local, nord ou façade reconnaissable. Ne répétez pas un identifiant à plusieurs endroits sauf s’il existe réellement plusieurs appareils. Un tableau de références peut relier symbole, ID, circuit et feuille. Le dossier reste ainsi exploitable sans miniaturiser les textes ni tracer des lignes ambiguës sur toute la page.",[23,1342,1344],{"id":1343},"exemple-deux-versants-et-un-onduleur-dans-le-local-technique","Exemple : deux versants et un onduleur dans le local technique",[11,1346,1347],{},"Prenons une maison avec modules sur versants est et ouest, deux chaînes DC et un onduleur dans le local technique. Représentez deux champs identifiés plutôt qu'une icône au milieu du toit. Indiquez quelle référence de chaîne appartient à chaque versant et où ses câbles DC entrent dans le bâtiment. Ne dessinez un trajet commun vers le local que si les canalisations posées suivent réellement ce chemin.",[11,1349,1350],{},"Attribuez à l'onduleur un repère stable et sa position réelle sur le mur. Si sectionnement DC, protection contre les surtensions ou autre matériel fixe est externe, localisez-le aussi et reliez son identifiant à l'unifilaire. Laissez les fonctions intégrées au dossier de l'appareil au lieu d'inventer des boîtiers. Le trajet AC aboutit au bon tableau et au bon circuit ; une ligne dirigée vers le local le plus proche ne donne aucune traçabilité.",[11,1352,1353],{},"Vérifiez l'orientation du détail de toiture. Versant, corniche, faîte, nord et contours reconnaissables doivent permettre de retrouver champ et pénétration sur place. Le plan de position n'est pas un plan mécanique et ne montre pas chaque crochet. Il représente toutefois les différences utiles à l'affectation électrique, au travail sûr et au diagnostic ultérieur.",[23,1355,1357],{"id":1356},"relever-honnêtement-les-chemins-cachés-ou-inaccessibles","Relever honnêtement les chemins cachés ou inaccessibles",[11,1359,1360],{},"N'inventez pas un tracé géométriquement exact lorsqu'une installation existante le masque. Signalez un tronçon caché ou repris d'une documentation conservée et gardez la source de l'information. Des photos des entrées, étiquettes, traversées et du local réduisent l'incertitude. Un trait interrompu n'a ce sens que si la légende le définit.",[11,1362,1363],{},"Séparez trois états de preuve : observé sur place, confirmé par un document technique fiable et encore à résoudre. Les inconnues vont dans une liste de relevé, pas sous forme de lignes certaines dans l'édition finale. Avant contrôle, le professionnel responsable décide si une investigation ou un accès supplémentaire est nécessaire.",[23,1365,1367],{"id":1366},"répercuter-chaque-modification-de-toiture","Répercuter chaque modification de toiture",[11,1369,1370],{},"Après remplacement de modules, extension de champ ou changement d'onduleur, révisez davantage que la surface du toit. Mettez à jour identifiants de champs et chaînes, trajet, point d'entrée, emplacement des appareils, références DC et AC et pièces techniques. Même si des modules sont remplacés dans une chaîne existante, conservez nombre et puissance réellement installés dans les informations du dossier. Une nouvelle répartition des chaînes doit apparaître de façon identique sur unifilaire et plan de position.",[11,1372,1373],{},"Archivez séparément l'ancienne édition avec sa date. Il devient possible de rattacher photo et rapport de contrôle au bon état. Le portail cloud de l'onduleur fournit éventuellement des données de production, mais ne remplace ni relevé spatial ni révision du plan.",[11,1375,1376,1377,1381],{},"La ",[86,1378,1380],{"href":341,"rel":1379},[343],"page officielle du SPF Économie sur les contrôles domestiques"," cite les sources d'énergie sur les deux plans et la documentation PV dans le dossier. Le détail nécessaire dépend de l'installation et du Livre 1 V06 actuel, pas d'un modèle de toiture générique.",[23,1383,1385],{"id":1384},"réaliser-le-plan-dans-planelec","Réaliser le plan dans PlanElec",[11,1387,1388,1389,1392],{},"Avec ",[86,1390,356],{"href":1391},"\u002Ffr\u002F",", vous placez les composants PV sur le plan de situation, saisissez la structure électrique sur l’unifilaire et exportez les deux PDF. Le logiciel reprend les données introduites. Son auto-contrôle indicatif peut signaler certaines informations prises en charge, sans remplacer le relevé sur place ou le contrôle agréé et sans certifier la conformité RGIE.",[23,1394,1396],{"id":1395},"sources-et-version","Sources et version",[11,1398,1399,1400,1404],{},"La base est la publication officielle du ",[86,1401,1403],{"href":367,"rel":1402},[343],"RGIE Livre 1"," : tableau 2.23, partie 3, chapitre 7.112, dérogation étroite de la partie 8 et dossier de la partie 9. Examen selon V06 au 29 août 2026.",{"title":135,"searchDepth":372,"depth":372,"links":1406},[1407,1408,1409,1410,1411,1412,1413,1419,1420,1421,1422,1423,1424,1425,1426],{"id":1072,"depth":372,"text":1073},{"id":1105,"depth":372,"text":1106},{"id":1137,"depth":372,"text":1138},{"id":1164,"depth":372,"text":1165},{"id":1183,"depth":372,"text":1184},{"id":1215,"depth":372,"text":1216},{"id":1247,"depth":372,"text":1248,"children":1414},[1415,1416,1417,1418],{"id":1251,"depth":383,"text":1252},{"id":1258,"depth":383,"text":1259},{"id":1265,"depth":383,"text":1266},{"id":1272,"depth":383,"text":1273},{"id":1279,"depth":372,"text":1280},{"id":1309,"depth":372,"text":1310},{"id":1333,"depth":372,"text":1334},{"id":1343,"depth":372,"text":1344},{"id":1356,"depth":372,"text":1357},{"id":1366,"depth":372,"text":1367},{"id":1384,"depth":372,"text":1385},{"id":1395,"depth":372,"text":1396},"Localisez modules PV, onduleur, sectionnements fixes, tableaux et cheminements sur le plan de situation avec les mêmes repères que l’unifilaire.","fr",{},"\u002Fblog\u002Fpv-situation-plan.fr",{"title":1057,"description":1427},"photovoltaique-plan-situation","blog\u002Fpv-situation-plan.fr",[1435,1436,1437,1438,1439,1440,1441],"Photovoltaïque","Plan de situation","Modules PV","Onduleur","RGIE","Cheminement","Belgique","HmvIof4wJuEzmShL7f9c1xp5V4LSZWbA2ySZgbsw7mg",{"id":1444,"title":1445,"articleId":6,"body":1446,"category":395,"date":396,"description":1820,"extension":398,"lastUpdated":396,"locale":1821,"meta":1822,"navigation":401,"path":1823,"publishDate":396,"readTime":403,"refreshInterval":404,"seo":1824,"slug":1825,"stem":1826,"tags":1827,"__hash__":1834},"blog\u002Fblog\u002Fpv-situation-plan.nl.md","Zonnepanelen op het situatieschema: modules, omvormer en kabeltraject",{"type":8,"value":1447,"toc":1798},[1448,1455,1458,1462,1465,1488,1491,1495,1498,1515,1523,1527,1530,1547,1550,1554,1557,1560,1566,1569,1573,1576,1593,1601,1605,1608,1611,1625,1633,1637,1641,1644,1648,1651,1655,1658,1662,1665,1669,1672,1692,1695,1699,1719,1723,1726,1729,1733,1736,1739,1742,1746,1749,1752,1756,1759,1762,1765,1768,1775,1779,1786,1790],[11,1449,1450,1451,1454],{},"Bij zonnepanelen krijgt het eendraadschema meestal de meeste aandacht. Daarop staan strings, omvormer, beveiligingen en aansluiting op het verdeelbord. Het situatieschema heeft een andere taak: de ",[15,1452,1453],{},"ruimtelijke ligging"," van de vaste elektrische onderdelen vastleggen. Voor onderhoud, verbouwing en controle moet duidelijk zijn op welk dakvlak de modules liggen, waar de omvormer hangt en hoe de vaste installatie het bord bereikt.",[11,1456,1457],{},"Een situatieschema is geen stabiliteitsplan van het dak en evenmin een volledig DC-schema. Het vult het eendraadschema aan zonder alle elektrische details dubbel te tekenen.",[23,1459,1461],{"id":1460},"werk-vanuit-een-actuele-as-built-basis","Werk vanuit een actuele as-built basis",[11,1463,1464],{},"Gebruik een herkenbaar grondplan met verdiepingen, lokalen, toegangen en belangrijke buitenzones. Voor een dakinstallatie kan een dakaanzicht of extra gevelaanzicht nodig zijn. Neem ter plaatse op:",[31,1466,1467,1470,1473,1476,1479,1482,1485],{},[34,1468,1469],{},"exacte modulevelden en oriëntatie;",[34,1471,1472],{},"positie van centrale of micro-omvormers;",[34,1474,1475],{},"vaste DC- en AC-scheiders voor zover aanwezig;",[34,1477,1478],{},"hoofd- of onderverdeelkast waarop de installatie aansluit;",[34,1480,1481],{},"vaste doorvoeren en belangrijke kabeltrajecten;",[34,1483,1484],{},"meter- of meetkast wanneer nodig voor de identificatie;",[34,1486,1487],{},"batterij, backup-omschakeling of andere bron indien onderdeel van het systeem.",[11,1489,1490],{},"Neem het offerteplan niet zonder controle over. Dakbezetting, omvormerlocatie en kabelroute veranderen vaak tijdens de uitvoering.",[23,1492,1494],{"id":1493},"wat-op-het-dakplan-thuishoort","Wat op het dakplan thuishoort",[11,1496,1497],{},"Teken het moduleveld zo dat de locatie ondubbelzinnig is. Afhankelijk van schaal en omvang toont u:",[31,1499,1500,1503,1506,1509,1512],{},[34,1501,1502],{},"afzonderlijke modules of duidelijk begrensde modulegroepen;",[34,1504,1505],{},"het juiste dakvlak, bijgebouw, gevelvlak of terrein;",[34,1507,1508],{},"stringreferenties wanneer die de koppeling met het eendraadschema verduidelijken;",[34,1510,1511],{},"vaste DC-verzamel- of schakelkasten;",[34,1513,1514],{},"relevante dakranden, toegangen of brandcompartimenten voor zover ze de elektrische ligging verklaren.",[11,1516,1517,1518,1522],{},"Niet elke stekker onder ieder paneel hoeft op het situatieschema. Stringschakeling, polariteit, geleidergegevens en beschermingsketen horen voornamelijk op het ",[86,1519,1521],{"href":1520},"\u002Fblog\u002Fzonnepanelen-schema","PV-eendraadschema",". Gebruik op beide documenten dezelfde string- en toestelcodes.",[23,1524,1526],{"id":1525},"de-omvormer-precies-plaatsen","De omvormer precies plaatsen",[11,1528,1529],{},"Maak de werkelijke montagepositie herkenbaar en onderscheid indien van toepassing:",[31,1531,1532,1535,1538,1541,1544],{},[34,1533,1534],{},"centrale stringomvormer;",[34,1536,1537],{},"meerdere omvormers;",[34,1539,1540],{},"micro-omvormers bij de modules;",[34,1542,1543],{},"hybride omvormer en afzonderlijke batterij;",[34,1545,1546],{},"bijbehorende vaste scheidings- of schakeltoestellen.",[11,1548,1549],{},"Alleen “garage” schrijven kan in een grote ruimte te vaag zijn. Plaats het symbool aan de juiste wand of technische zone. Bij buitenmontage moet de gevelzijde duidelijk zijn.",[23,1551,1553],{"id":1552},"kabeltrajecten-functioneel-tekenen","Kabeltrajecten functioneel tekenen",[11,1555,1556],{},"Een bruikbaar plan maakt zichtbaar hoe de vaste verbinding van het moduleveld naar de omvormer en vervolgens naar het verdeelbord loopt. Toon vooral gebouwdoorvoeren, kokers, stijgzones en verdiepingswissels die later uit zicht zijn.",[11,1558,1559],{},"Maak DC- en AC-traject onderscheidbaar met lijnsoort of tekst, niet uitsluitend met kleur. Een zwart-witafdruk moet leesbaar blijven. Bijvoorbeeld:",[129,1561,1564],{"className":1562,"code":1563,"language":134,"meta":135},[132],"PV-DC  ─ ─ ─  gelijkstroomtraject vanaf het moduleveld\nPV-AC  ─────  wisselstroomtraject naar het verdeelbord\nDATA   ·····  vaste meet- of communicatielijn\n",[137,1565,1563],{"__ignoreMap":135},[11,1567,1568],{},"Definieer de lijnen in de legende. Ze beschrijven geen kabeltype of plaatsingswijze; die gegevens staan bij de juiste kring op het eendraadschema.",[23,1570,1572],{"id":1571},"symbolen-en-projectlegende","Symbolen en projectlegende",[11,1574,1575],{},"Tabel 2.23 van AREI Boek 1 V06 is niet uitputtend. Een duidelijk projectsymbool voor moduleveld, omvormer of DC-scheider kan worden gebruikt wanneer de legende het vastlegt. Zorg voor:",[31,1577,1578,1581,1584,1587,1590],{},[34,1579,1580],{},"voldoende grootte in de uiteindelijke PDF;",[34,1582,1583],{},"een ander teken of bijschrift voor omvormer en batterij;",[34,1585,1586],{},"vaste referenties op elke pagina;",[34,1588,1589],{},"onderscheid dat niet alleen van kleur afhangt;",[34,1591,1592],{},"scheiding tussen elektrisch toestel en bouwkundig object.",[11,1594,1595,1596,1600],{},"De ",[86,1597,1599],{"href":1598},"\u002Fblog\u002Farei-elektrische-symbolen-overzicht","AREI-symbolengids"," bespreekt de legende en technische bijschriften uitgebreider.",[23,1602,1604],{"id":1603},"gedeelde-referenties-met-het-eendraadschema","Gedeelde referenties met het eendraadschema",[11,1606,1607],{},"Deel 3 van AREI Boek 1 V06 gebruikt voor beide plannen een samenhangende kringreferentie. De AC-aftakking van de omvormer draagt op het situatieschema dus dezelfde code als op het eendraadschema. Als string- of toestelreferenties op beide voorkomen, moeten ook die gelijk zijn.",[11,1609,1610],{},"Controleer in twee richtingen:",[185,1612,1613,1616,1619,1622],{},[34,1614,1615],{},"Elk vast PV-element op het situatieschema is terug te vinden op het eendraadschema of in de legende.",[34,1617,1618],{},"Elk ruimtelijk relevant PV-onderdeel van het eendraadschema heeft een vindbare positie.",[34,1620,1621],{},"Namen van verdeelborden en verdiepingen komen overeen.",[34,1623,1624],{},"Adres, datum en documentversie zijn gelijk.",[11,1626,1627,1628,1632],{},"Lees ",[86,1629,1631],{"href":1630},"\u002Fblog\u002Feendraadschema-vs-situatieschema","eendraadschema versus situatieschema"," voor de precieze taakverdeling.",[23,1634,1636],{"id":1635},"bijzondere-opstellingen","Bijzondere opstellingen",[212,1638,1640],{"id":1639},"micro-omvormers","Micro-omvormers",[11,1642,1643],{},"Bij veel identieke toestellen is een gegroepeerd symbool met aantal, type en modulegroep vaak leesbaarder dan overlappende tekens. De elektrische parallelschakeling blijft op het eendraadschema zichtbaar.",[212,1645,1647],{"id":1646},"thuisbatterij","Thuisbatterij",[11,1649,1650],{},"Plaats batterij, omvormer, vaste scheiders en een eventuele backupverdeler. Een batterij is geen PV-module en krijgt een eigen symbool. Afstanden en opstellingsvoorwaarden komen uit ontwerp en fabrikantdocumentatie; het plan registreert de uitgevoerde positie.",[212,1652,1654],{"id":1653},"bijgebouw-of-vrijstaande-installatie","Bijgebouw of vrijstaande installatie",[11,1656,1657],{},"Toon het traject tussen gebouwen, de invoer en betrokken onderverdeelkasten. Een pijl “naar woning” zonder exact eindpunt is onvoldoende voor toekomstig werk.",[212,1659,1661],{"id":1660},"bestaande-installatie","Bestaande installatie",[11,1663,1664],{},"Deel 8 kent voor bepaalde bestaande huishoudelijke PV-installaties tot 10 kVA een beperkte afwijking waarbij een schriftelijke beschrijving, eventueel aangevuld met foto’s, kan volstaan. Veralgemeen die overgangsregel niet tot nieuwbouw of een belangrijke wijziging. Laat het toepassingsgeval beoordelen.",[23,1666,1668],{"id":1667},"dossier-en-fotos","Dossier en foto’s",[11,1670,1671],{},"Foto’s zijn nuttig voor verborgen trajecten, daken en typeplaten, maar vervangen de gestructureerde plannen niet automatisch. Bewaar minstens:",[31,1673,1674,1677,1680,1683,1686,1689],{},[34,1675,1676],{},"definitief situatieschema en eendraadschema;",[34,1678,1679],{},"module- en omvormergegevens;",[34,1681,1682],{},"beschikbare string- en meetinformatie;",[34,1684,1685],{},"handleidingen en toestelverklaringen;",[34,1687,1688],{},"verslagen van een erkend controleorganisme;",[34,1690,1691],{},"latere wijzigingen met een nieuwe documentversie.",[11,1693,1694],{},"De eigenaar houdt het dossier beschikbaar en laat het bij wijzigingen actualiseren.",[23,1696,1698],{"id":1697},"controle-vóór-export","Controle vóór export",[31,1700,1701,1704,1707,1710,1713,1716],{},[34,1702,1703],{},"Staan modulevelden, omvormers en vaste extra toestellen op hun echte plaats?",[34,1705,1706],{},"Zijn DC- en AC-route herkenbaar en in de legende uitgelegd?",[34,1708,1709],{},"Komen kring-, string- en bordreferenties overeen met het eendraadschema?",[34,1711,1712],{},"Blijven symbolen en tekst leesbaar in het gekozen papierformaat?",[34,1714,1715],{},"Is dit de as-built toestand en niet alleen het oorspronkelijke voorstel?",[34,1717,1718],{},"Dragen beide plannen hetzelfde adres, dezelfde datum en versie?",[23,1720,1722],{"id":1721},"een-plan-over-meerdere-bladen-organiseren","Een plan over meerdere bladen organiseren",[11,1724,1725],{},"Wanneer dak, technische ruimte en verdeelborden niet leesbaar op één blad passen, gebruikt u benoemde deelplannen. Een overzicht toont de relatie tussen gebouw, dakvlakken en borden; detailbladen vergroten modulevelden en technische zones. Geef elk blad een nummer en gebruik duidelijke vervolgverwijzingen, bijvoorbeeld “PV-DC verder op blad S2”.",[11,1727,1728],{},"Elke uitsnede behoudt voldoende oriëntatie: verdieping, lokaal, noordpijl of herkenbare gevelzijde. Plaats dezelfde toestelcode niet op verschillende locaties tenzij er werkelijk meerdere toestellen zijn. Een compacte referentietabel kan symbool, toestel-ID, kring en blad koppelen. Daardoor blijft een groot project controleerbaar zonder onleesbaar kleine symbolen of lijnen die over de hele pagina lopen. Bij een latere uitbreiding moet ook de bladindex worden aangepast, anders kan een oud detailblad ten onrechte als actueel worden gelezen.",[23,1730,1732],{"id":1731},"praktijkvoorbeeld-twee-dakvlakken-en-één-omvormer-in-de-technische-ruimte","Praktijkvoorbeeld: twee dakvlakken en één omvormer in de technische ruimte",[11,1734,1735],{},"Neem een woning met modules op oost- en westdak, twee DC-strings en één omvormer in de technische ruimte. Teken twee afzonderlijk geïdentificeerde modulevelden in plaats van één pictogram midden op het dak. Geef aan welke stringreferentie bij elk vlak hoort en waar de DC-kabels het gebouw binnenkomen. Teken een gedeeld traject naar de technische ruimte alleen wanneer de geplaatste kabels dat traject werkelijk delen.",[11,1737,1738],{},"Geef de omvormer een vaste toestelcode en zijn echte wandpositie. Zijn DC-scheiding, overspanningsbeveiliging of andere vaste onderdelen extern, lokaliseer die dan ook en verbind hun identificatie met het eendraadschema. Houd geïntegreerde functies bij het toestel in plaats van losse kasten te verzinnen. Het AC-traject eindigt bij het juiste bord en de juiste kring; een lijn naar het dichtstbijzijnde lokaal biedt geen traceerbaarheid.",[11,1740,1741],{},"Controleer de oriëntatie van elk dakdetail. Dakvlak, goot, nok, noordrichting en herkenbare gebouwranden moeten veld en invoerpunt ter plaatse vindbaar maken. Het situatieplan is geen mechanisch montageplan en toont niet elke haak. Het geeft wel verschillen weer die voor elektrische toewijzing, veilig werk en latere foutopsporing relevant zijn.",[23,1743,1745],{"id":1744},"verborgen-of-ontoegankelijke-trajecten-eerlijk-opnemen","Verborgen of ontoegankelijke trajecten eerlijk opnemen",[11,1747,1748],{},"Verzin geen geometrisch exacte route waar een bestaande installatie ze verbergt. Markeer een deel als verborgen of overgenomen uit bewaarde documentatie en houd de bron van die informatie bij. Foto's van invoerpunten, labels, doorvoeren en technische ruimte beperken de onzekerheid. Een stippellijn krijgt die betekenis alleen als de legende ze definieert.",[11,1750,1751],{},"Onderscheid drie bewijsniveaus: ter plaatse gezien, bevestigd door betrouwbare technische stukken en nog uit te zoeken. Open punten horen in een opnamelijst, niet als schijnbaar zekere lijn in de eindversie. Vóór controle beslist de verantwoordelijke vakpersoon of meer onderzoek of toegang nodig is.",[23,1753,1755],{"id":1754},"dakwijzigingen-volledig-verwerken","Dakwijzigingen volledig verwerken",[11,1757,1758],{},"Controleer na modulevervanging, uitbreiding of een nieuwe omvormer meer dan de zichtbare dakzone. Werk veld- en stringcodes, kabelroute, invoerpunt, toestelplaats, DC- en AC-referenties en technische documenten bij. Ook bij vervanging binnen een bestaande string blijven werkelijk aantal en nominaal vermogen in de juiste dossierinformatie bewaard. Worden strings anders verdeeld, dan dragen eendraadschema en situatieplan dezelfde nieuwe toestand.",[11,1760,1761],{},"Archiveer de vervangen versie afzonderlijk met datum. Zo blijft duidelijk of een foto of keuringsverslag bij de oude of actuele opstelling hoort. Een cloudportaal van de omvormer kan productiegegevens tonen, maar vervangt geen ruimtelijke opname of planrevisie.",[11,1763,1764],{},"Kijk bij de revisie ook naar de leesbaarheid op papier. Een extra veld mag bestaande referenties niet bedekken en een nieuw kabeltraject mag niet dezelfde lijnstijl krijgen als een bouwkundige rand. Verplaats detailkaders gecontroleerd, pas de bladindex aan en controleer alle verwijzingen opnieuw. Daardoor blijft ook een uitgebreide installatie op normale afdrukgrootte bruikbaar.",[11,1766,1767],{},"Neem ten slotte de veldcodes over op duurzame labels waar dat technisch voorzien is. Controleer dat het label bij het juiste traject of toestel hoort en in normale onderhoudssituaties leesbaar blijft. Een code op het plan heeft weinig waarde wanneer ter plaatse niet kan worden bepaald op welk moduleveld of welke omvormer ze slaat.",[11,1769,1595,1770,1774],{},[86,1771,1773],{"href":341,"rel":1772},[343],"officiële FOD-pagina over huishoudelijke controles"," noemt energiebronnen op beide plannen en PV-technische documentatie in het dossier. Het vereiste detail volgt de installatie en het actuele officiële Boek 1 V06, niet een algemeen daksjabloon.",[23,1776,1778],{"id":1777},"tekenen-met-planelec","Tekenen met PlanElec",[11,1780,1781,1782,1785],{},"Met ",[86,1783,356],{"href":1784},"\u002F"," plaatst u PV-componenten op het situatieschema, legt u de structuur vast op het eendraadschema en exporteert u beide als PDF. De software neemt de ingevoerde projectgegevens over. De oriënterende zelfcheck kan ondersteunde informatie signaleren, maar vervangt geen terreincontrole of erkende keuring en bevestigt geen AREI-conformiteit.",[23,1787,1789],{"id":1788},"bronnen-en-versie","Bronnen en versie",[11,1791,1792,1793,1797],{},"Basis is de officiële publicatie van ",[86,1794,1796],{"href":367,"rel":1795},[343],"AREI\u002FRGIE Boek 1",": tabel 2.23, deel 3, hoofdstuk 7.112, de beperkte bestaande-installatieregel in deel 8 en het dossier in deel 9. Gecontroleerd volgens V06 op 29 augustus 2026.",{"title":135,"searchDepth":372,"depth":372,"links":1799},[1800,1801,1802,1803,1804,1805,1806,1812,1813,1814,1815,1816,1817,1818,1819],{"id":1460,"depth":372,"text":1461},{"id":1493,"depth":372,"text":1494},{"id":1525,"depth":372,"text":1526},{"id":1552,"depth":372,"text":1553},{"id":1571,"depth":372,"text":1572},{"id":1603,"depth":372,"text":1604},{"id":1635,"depth":372,"text":1636,"children":1807},[1808,1809,1810,1811],{"id":1639,"depth":383,"text":1640},{"id":1646,"depth":383,"text":1647},{"id":1653,"depth":383,"text":1654},{"id":1660,"depth":383,"text":1661},{"id":1667,"depth":372,"text":1668},{"id":1697,"depth":372,"text":1698},{"id":1721,"depth":372,"text":1722},{"id":1731,"depth":372,"text":1732},{"id":1744,"depth":372,"text":1745},{"id":1754,"depth":372,"text":1755},{"id":1777,"depth":372,"text":1778},{"id":1788,"depth":372,"text":1789},"Plaats PV-modules, omvormer, vaste scheiders, verdeelborden en kabeltrajecten op het situatieschema en houd de referenties gelijk aan het eendraadschema.","nl",{},"\u002Fblog\u002Fpv-situation-plan.nl",{"title":1445,"description":1820},"zonnepanelen-situatieschema","blog\u002Fpv-situation-plan.nl",[1828,1829,1830,1831,413,1832,1833],"Zonnepanelen","Situatieschema","PV-modules","Omvormer","Kabeltraject","België","M8g91BBa0cXFELgk8vCP76PqEVfWX9tcLCW-AGGkjaU",1788343866128]