[{"data":1,"prerenderedAt":1240},["ShallowReactive",2],{"blog-post-en-what-is-a-situation-plan":3,"blog-alternates-what-is-a-situation-plan":299},{"id":4,"title":5,"articleId":6,"body":7,"category":274,"date":275,"description":276,"extension":277,"lastUpdated":275,"locale":278,"meta":279,"navigation":280,"path":281,"publishDate":275,"readTime":282,"refreshInterval":283,"seo":284,"slug":6,"stem":285,"tags":286,"__hash__":298},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.en.md","What Is a Situation Plan?","what-is-a-situation-plan",{"type":8,"value":9,"toc":262},"minimark",[10,15,33,40,44,51,100,107,111,116,151,155,234,237,241,256],[11,12,14],"h2",{"id":13},"a-floor-plan-of-your-electrical-installation","A floor plan of your electrical installation",[16,17,18,19,23,24,27,28,32],"p",{},"A situation plan (Dutch: ",[20,21,22],"em",{},"situatieschema",", French: ",[20,25,26],{},"plan de situation",") is a scaled floor plan of your building showing the ",[29,30,31],"strong",{},"physical location"," of all electrical components — sockets, switches, lights, distribution boards, and cable routes.",[16,34,35,36,39],{},"Unlike a single-line diagram, the situation plan doesn't show the logical circuit hierarchy, but rather ",[29,37,38],{},"exactly where"," everything is located.",[11,41,43],{"id":42},"what-does-the-arei-say","What does the AREI say?",[16,45,46,47,50],{},"According to AREI Art. 9.1 (Art. 269 in the old AREI, since 2020 Art. 9.1), every electrical installation in Belgium must have ",[29,48,49],{},"two mandatory drawing documents",":",[52,53,54,70],"table",{},[55,56,57],"thead",{},[58,59,60,64,67],"tr",{},[61,62,63],"th",{},"Document",[61,65,66],{},"AREI Article",[61,68,69],{},"Shows",[71,72,73,87],"tbody",{},[58,74,75,81,84],{},[76,77,78],"td",{},[29,79,80],{},"Single-line diagram",[76,82,83],{},"Art. 9.1.2 Nr. 1",[76,85,86],{},"Logical structure — protection devices, circuits, hierarchy",[58,88,89,94,97],{},[76,90,91],{},[29,92,93],{},"Situation plan",[76,95,96],{},"Art. 9.1.2 Nr. 2",[76,98,99],{},"Physical location — where everything is installed in the building, incl. location of the meter board and earthing system",[16,101,102,103,106],{},"Both documents must be presented at every electrical inspection (",[20,104,105],{},"keuring","). If either of them is missing, the inspection will not pass.",[11,108,110],{"id":109},"what-must-be-on-the-situation-plan","What must be on the situation plan?",[112,113,115],"h3",{"id":114},"checklist","Checklist",[117,118,119,123,126,129,132,135,138,141,148],"ul",{},[120,121,122],"li",{},"Scaled floor plan of each storey",[120,124,125],{},"Position of all sockets (single, double, earthed)",[120,127,128],{},"Position of all switches (on\u002Foff, two-way, dimmer)",[120,130,131],{},"Lighting points (ceiling, wall, outdoor)",[120,133,134],{},"Distribution board and meter location",[120,136,137],{},"Fixed appliances (hob, boiler, EV charger)",[120,139,140],{},"Cable routes and installation zones",[120,142,143,144,147],{},"Circuit reference numbers (numbering must be ",[29,145,146],{},"identical"," between situation plan and single-line diagram)",[120,149,150],{},"AREI-compliant symbols (per IEC 60617)",[11,152,154],{"id":153},"situation-plan-vs-single-line-diagram","Situation plan vs. single-line diagram",[52,156,157,168],{},[55,158,159],{},[58,160,161,164,166],{},[61,162,163],{},"Property",[61,165,93],{},[61,167,80],{},[71,169,170,181,192,202,213,224],{},[58,171,172,175,178],{},[76,173,174],{},"Representation",[76,176,177],{},"Physical floor plan",[76,179,180],{},"Logical circuit diagram",[58,182,183,186,189],{},[76,184,185],{},"Shows position?",[76,187,188],{},"Yes — exact location",[76,190,191],{},"No",[58,193,194,197,199],{},[76,195,196],{},"Shows hierarchy?",[76,198,191],{},[76,200,201],{},"Yes — from grid to consumer",[58,203,204,207,210],{},[76,205,206],{},"Protection devices",[76,208,209],{},"Position only",[76,211,212],{},"Ratings, type, coordination",[58,214,215,218,221],{},[76,216,217],{},"Cable info",[76,219,220],{},"Routes visible",[76,222,223],{},"Type and cross-section listed",[58,225,226,229,232],{},[76,227,228],{},"Scaled",[76,230,231],{},"Yes (1:50 or 1:100)",[76,233,191],{},[16,235,236],{},"Both documents complement each other and are equally mandatory.",[11,238,240],{"id":239},"related-articles","Related articles",[117,242,243,250],{},[120,244,245],{},[246,247,249],"a",{"href":248},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","How to create a single-line diagram — step by step",[120,251,252],{},[246,253,255],{"href":254},"\u002Fen\u002Fblog\u002Felectrical-plan-costs","How much does an electrical plan cost in Belgium?",[16,257,258],{},[246,259,261],{"href":260},"\u002F","Create your situation plan with PlanElec now — free →",{"title":263,"searchDepth":264,"depth":264,"links":265},"",2,[266,267,268,272,273],{"id":13,"depth":264,"text":14},{"id":42,"depth":264,"text":43},{"id":109,"depth":264,"text":110,"children":269},[270],{"id":114,"depth":271,"text":115},3,{"id":153,"depth":264,"text":154},{"id":239,"depth":264,"text":240},"faq","2026-03-06","A situation plan shows where all electrical components are physically installed in your building. Learn what it must include and how it differs from a single-line diagram.","md","en",{},true,"\u002Fblog\u002Fwhat-is-a-situation-plan.en","3 min",12,{"title":5,"description":276},"blog\u002Fwhat-is-a-situation-plan.en",[287,288,289,22,290,26,291,292,293,294,295,105,296,297],"AREI","RGIE","situation plan","Situationsplan","single-line diagram","eendraadschema","Eindrahtschema","schéma unifilaire","inspection","floor plan","Belgium","L37ctZf9sqmXWK3fnFWRKe_-PEAdS0xHUJTJtp4usr8",[300,558,739,989],{"id":301,"title":302,"articleId":6,"body":303,"category":274,"date":275,"description":544,"extension":277,"lastUpdated":275,"locale":545,"meta":546,"navigation":280,"path":547,"publishDate":275,"readTime":282,"refreshInterval":283,"seo":548,"slug":549,"stem":550,"tags":551,"__hash__":557},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.de.md","Was ist ein Situationsplan?",{"type":8,"value":304,"toc":535},[305,309,322,329,333,340,379,385,389,393,426,430,509,512,516,530],[11,306,308],{"id":307},"ein-grundriss-ihrer-elektroinstallation","Ein Grundriss Ihrer Elektroinstallation",[16,310,311,312,314,315,317,318,321],{},"Der Situationsplan (niederländisch: ",[20,313,22],{},", französisch: ",[20,316,26],{},") ist ein maßstabsgetreuer Grundriss Ihres Gebäudes, auf dem die ",[29,319,320],{},"physische Position"," aller elektrischen Komponenten eingezeichnet ist — Steckdosen, Schalter, Leuchten, Verteilerkasten und Kabelwege.",[16,323,324,325,328],{},"Anders als das Eindrahtschema zeigt der Situationsplan nicht die logische Schaltungshierarchie, sondern ",[29,326,327],{},"wo genau"," sich alles befindet.",[11,330,332],{"id":331},"was-sagt-das-arei","Was sagt das AREI?",[16,334,335,336,339],{},"Gemäß AREI Art. 9.1 (Art. 269 im alten AREI, seit 2020 Art. 9.1) muss jede elektrische Installation in Belgien über ",[29,337,338],{},"zwei zeichnerische Pflichtdokumente"," verfügen:",[52,341,342,355],{},[55,343,344],{},[58,345,346,349,352],{},[61,347,348],{},"Dokument",[61,350,351],{},"AREI-Artikel",[61,353,354],{},"Zeigt",[71,356,357,368],{},[58,358,359,363,365],{},[76,360,361],{},[29,362,293],{},[76,364,83],{},[76,366,367],{},"Logische Struktur — Schutzgeräte, Stromkreise, Hierarchie",[58,369,370,374,376],{},[76,371,372],{},[29,373,290],{},[76,375,96],{},[76,377,378],{},"Physische Position — wo ist alles im Gebäude installiert, inkl. Lage des Zählerkastens und der Erdungsanlage",[16,380,381,382,384],{},"Beide Dokumente sind bei jeder elektrischen Abnahme (",[20,383,105],{},") vorzulegen. Fehlt eines davon, wird die Abnahme nicht bestanden.",[11,386,388],{"id":387},"was-muss-auf-den-situationsplan","Was muss auf den Situationsplan?",[112,390,392],{"id":391},"checkliste","Checkliste",[117,394,395,398,401,404,407,410,413,416,423],{},[120,396,397],{},"Maßstabsgetreuer Grundriss jeder Etage",[120,399,400],{},"Position aller Steckdosen (Einzel, Doppel, mit Erdung)",[120,402,403],{},"Position aller Schalter (Ein\u002FAus, Wechsel, Dimmer)",[120,405,406],{},"Beleuchtungspunkte (Decke, Wand, Außen)",[120,408,409],{},"Verteilerkasten und Zählerposition",[120,411,412],{},"Festanschlussgeräte (Kochfeld, Boiler, Wallbox)",[120,414,415],{},"Kabelverläufe und Installationszonen",[120,417,418,419,422],{},"Stromkreis-Referenznummern (die Nummerierung muss zwischen Situationsplan und Eindrahtschema ",[29,420,421],{},"identisch"," sein)",[120,424,425],{},"AREI-konforme Symbole (nach IEC 60617)",[11,427,429],{"id":428},"situationsplan-vs-eindrahtschema","Situationsplan vs. Eindrahtschema",[52,431,432,443],{},[55,433,434],{},[58,435,436,439,441],{},[61,437,438],{},"Eigenschaft",[61,440,290],{},[61,442,293],{},[71,444,445,456,467,477,488,499],{},[58,446,447,450,453],{},[76,448,449],{},"Darstellung",[76,451,452],{},"Physischer Grundriss",[76,454,455],{},"Logisches Schaltbild",[58,457,458,461,464],{},[76,459,460],{},"Zeigt Position?",[76,462,463],{},"Ja — wo genau",[76,465,466],{},"Nein",[58,468,469,472,474],{},[76,470,471],{},"Zeigt Hierarchie?",[76,473,466],{},[76,475,476],{},"Ja — vom Netz bis zum Verbraucher",[58,478,479,482,485],{},[76,480,481],{},"Schutzgeräte",[76,483,484],{},"Nur Position",[76,486,487],{},"Nennwerte, Typ, Koordination",[58,489,490,493,496],{},[76,491,492],{},"Kabelangaben",[76,494,495],{},"Verläufe sichtbar",[76,497,498],{},"Typ und Querschnitt angegeben",[58,500,501,504,507],{},[76,502,503],{},"Maßstab",[76,505,506],{},"Ja (1:50 oder 1:100)",[76,508,466],{},[16,510,511],{},"Beide Dokumente ergänzen sich und sind gleichermaßen Pflicht.",[11,513,515],{"id":514},"verwandte-artikel","Verwandte Artikel",[117,517,518,524],{},[120,519,520],{},[246,521,523],{"href":522},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema selbst erstellen — Schritt für Schritt",[120,525,526],{},[246,527,529],{"href":528},"\u002Fde\u002Fblog\u002Felektroplan-kosten","Was kostet ein Elektroplan in Belgien?",[16,531,532],{},[246,533,534],{"href":260},"Erstellen Sie jetzt Ihren Situationsplan mit PlanElec — kostenlos →",{"title":263,"searchDepth":264,"depth":264,"links":536},[537,538,539,542,543],{"id":307,"depth":264,"text":308},{"id":331,"depth":264,"text":332},{"id":387,"depth":264,"text":388,"children":540},[541],{"id":391,"depth":271,"text":392},{"id":428,"depth":264,"text":429},{"id":514,"depth":264,"text":515},"Der Situationsplan zeigt, wo alle elektrischen Komponenten in Ihrem Gebäude physisch installiert sind. Erfahren Sie, was drauf muss und wie er sich vom Eindrahtschema unterscheidet.","de",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.de",{"title":302,"description":544},"was-ist-ein-situationsplan","blog\u002Fwhat-is-a-situation-plan.de",[287,288,290,22,26,289,293,552,294,553,554,555,556],"Eendraadschema","Stromabnahme","Keuring","Grundriss","Belgien","HmVy22SOSP0z-6dQvTD1e3fV9vaZ6Gw3N7iXwvVSe1U",{"id":4,"title":5,"articleId":6,"body":559,"category":274,"date":275,"description":276,"extension":277,"lastUpdated":275,"locale":278,"meta":736,"navigation":280,"path":281,"publishDate":275,"readTime":282,"refreshInterval":283,"seo":737,"slug":6,"stem":285,"tags":738,"__hash__":298},{"type":8,"value":560,"toc":727},[561,563,571,575,577,581,615,619,621,623,645,647,709,711,713,723],[11,562,14],{"id":13},[16,564,18,565,23,567,27,569,32],{},[20,566,22],{},[20,568,26],{},[29,570,31],{},[16,572,35,573,39],{},[29,574,38],{},[11,576,43],{"id":42},[16,578,46,579,50],{},[29,580,49],{},[52,582,583,593],{},[55,584,585],{},[58,586,587,589,591],{},[61,588,63],{},[61,590,66],{},[61,592,69],{},[71,594,595,605],{},[58,596,597,601,603],{},[76,598,599],{},[29,600,80],{},[76,602,83],{},[76,604,86],{},[58,606,607,611,613],{},[76,608,609],{},[29,610,93],{},[76,612,96],{},[76,614,99],{},[16,616,102,617,106],{},[20,618,105],{},[11,620,110],{"id":109},[112,622,115],{"id":114},[117,624,625,627,629,631,633,635,637,639,643],{},[120,626,122],{},[120,628,125],{},[120,630,128],{},[120,632,131],{},[120,634,134],{},[120,636,137],{},[120,638,140],{},[120,640,143,641,147],{},[29,642,146],{},[120,644,150],{},[11,646,154],{"id":153},[52,648,649,659],{},[55,650,651],{},[58,652,653,655,657],{},[61,654,163],{},[61,656,93],{},[61,658,80],{},[71,660,661,669,677,685,693,701],{},[58,662,663,665,667],{},[76,664,174],{},[76,666,177],{},[76,668,180],{},[58,670,671,673,675],{},[76,672,185],{},[76,674,188],{},[76,676,191],{},[58,678,679,681,683],{},[76,680,196],{},[76,682,191],{},[76,684,201],{},[58,686,687,689,691],{},[76,688,206],{},[76,690,209],{},[76,692,212],{},[58,694,695,697,699],{},[76,696,217],{},[76,698,220],{},[76,700,223],{},[58,702,703,705,707],{},[76,704,228],{},[76,706,231],{},[76,708,191],{},[16,710,236],{},[11,712,240],{"id":239},[117,714,715,719],{},[120,716,717],{},[246,718,249],{"href":248},[120,720,721],{},[246,722,255],{"href":254},[16,724,725],{},[246,726,261],{"href":260},{"title":263,"searchDepth":264,"depth":264,"links":728},[729,730,731,734,735],{"id":13,"depth":264,"text":14},{"id":42,"depth":264,"text":43},{"id":109,"depth":264,"text":110,"children":732},[733],{"id":114,"depth":271,"text":115},{"id":153,"depth":264,"text":154},{"id":239,"depth":264,"text":240},{},{"title":5,"description":276},[287,288,289,22,290,26,291,292,293,294,295,105,296,297],{"id":740,"title":741,"articleId":6,"body":742,"category":274,"date":275,"description":977,"extension":277,"lastUpdated":275,"locale":978,"meta":979,"navigation":280,"path":980,"publishDate":275,"readTime":282,"refreshInterval":283,"seo":981,"slug":982,"stem":983,"tags":984,"__hash__":988},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.fr.md","Qu'est-ce qu'un plan de situation ?",{"type":8,"value":743,"toc":968},[744,748,761,768,772,779,819,822,826,830,859,863,942,945,949,963],[11,745,747],{"id":746},"un-plan-au-sol-de-votre-installation-électrique","Un plan au sol de votre installation électrique",[16,749,750,751,753,754,756,757,760],{},"Le plan de situation (néerlandais : ",[20,752,22],{},", allemand : ",[20,755,290],{},") est un plan à l'échelle de votre bâtiment montrant la ",[29,758,759],{},"position physique"," de tous les composants électriques — prises, interrupteurs, luminaires, tableaux de distribution et chemins de câbles.",[16,762,763,764,767],{},"Contrairement au schéma unifilaire, le plan de situation ne montre pas la hiérarchie logique des circuits, mais ",[29,765,766],{},"où exactement"," tout se trouve.",[11,769,771],{"id":770},"que-dit-le-rgie","Que dit le RGIE ?",[16,773,774,775,778],{},"Selon le RGIE Art. 9.1 (Art. 269 dans l'ancien RGIE, depuis 2020 Art. 9.1), toute installation électrique en Belgique doit disposer de ",[29,776,777],{},"deux documents graphiques obligatoires"," :",[52,780,781,793],{},[55,782,783],{},[58,784,785,787,790],{},[61,786,63],{},[61,788,789],{},"Article RGIE",[61,791,792],{},"Montre",[71,794,795,807],{},[58,796,797,802,804],{},[76,798,799],{},[29,800,801],{},"Schéma unifilaire",[76,803,83],{},[76,805,806],{},"Structure logique — dispositifs de protection, circuits, hiérarchie",[58,808,809,814,816],{},[76,810,811],{},[29,812,813],{},"Plan de situation",[76,815,96],{},[76,817,818],{},"Position physique — où tout est installé dans le bâtiment, y compris l'emplacement du compteur et du système de mise à la terre",[16,820,821],{},"Les deux documents doivent être présentés lors de chaque contrôle électrique. Si l'un d'entre eux manque, le contrôle ne sera pas réussi.",[11,823,825],{"id":824},"que-doit-contenir-le-plan-de-situation","Que doit contenir le plan de situation ?",[112,827,829],{"id":828},"liste-de-vérification","Liste de vérification",[117,831,832,835,838,841,844,847,850,853,856],{},[120,833,834],{},"Plan à l'échelle de chaque étage",[120,836,837],{},"Position de toutes les prises (simple, double, avec terre)",[120,839,840],{},"Position de tous les interrupteurs (on\u002Foff, va-et-vient, variateur)",[120,842,843],{},"Points lumineux (plafond, mur, extérieur)",[120,845,846],{},"Tableau de distribution et emplacement du compteur",[120,848,849],{},"Appareils fixes (plaque de cuisson, chauffe-eau, borne de recharge)",[120,851,852],{},"Chemins de câbles et zones d'installation",[120,854,855],{},"Numéros de référence des circuits (doivent correspondre au schéma unifilaire)",[120,857,858],{},"Symboles conformes au RGIE (selon IEC 60617)",[11,860,862],{"id":861},"plan-de-situation-vs-schéma-unifilaire","Plan de situation vs. schéma unifilaire",[52,864,865,876],{},[55,866,867],{},[58,868,869,872,874],{},[61,870,871],{},"Propriété",[61,873,813],{},[61,875,801],{},[71,877,878,889,900,910,921,932],{},[58,879,880,883,886],{},[76,881,882],{},"Représentation",[76,884,885],{},"Plan au sol physique",[76,887,888],{},"Schéma logique des circuits",[58,890,891,894,897],{},[76,892,893],{},"Montre la position ?",[76,895,896],{},"Oui — emplacement exact",[76,898,899],{},"Non",[58,901,902,905,907],{},[76,903,904],{},"Montre la hiérarchie ?",[76,906,899],{},[76,908,909],{},"Oui — du réseau au consommateur",[58,911,912,915,918],{},[76,913,914],{},"Dispositifs de protection",[76,916,917],{},"Position uniquement",[76,919,920],{},"Calibres, type, coordination",[58,922,923,926,929],{},[76,924,925],{},"Info câbles",[76,927,928],{},"Chemins visibles",[76,930,931],{},"Type et section indiqués",[58,933,934,937,940],{},[76,935,936],{},"À l'échelle",[76,938,939],{},"Oui (1:50 ou 1:100)",[76,941,899],{},[16,943,944],{},"Les deux documents se complètent et sont également obligatoires.",[11,946,948],{"id":947},"articles-connexes","Articles connexes",[117,950,951,957],{},[120,952,953],{},[246,954,956],{"href":955},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire — étape par étape",[120,958,959],{},[246,960,962],{"href":961},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique en Belgique ?",[16,964,965],{},[246,966,967],{"href":260},"Créez votre plan de situation avec PlanElec — gratuit →",{"title":263,"searchDepth":264,"depth":264,"links":969},[970,971,972,975,976],{"id":746,"depth":264,"text":747},{"id":770,"depth":264,"text":771},{"id":824,"depth":264,"text":825,"children":973},[974],{"id":828,"depth":271,"text":829},{"id":861,"depth":264,"text":862},{"id":947,"depth":264,"text":948},"Le plan de situation montre où tous les composants électriques sont physiquement installés dans votre bâtiment. Découvrez ce qu'il doit contenir et comment il se distingue du schéma unifilaire.","fr",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.fr",{"title":741,"description":977},"plan-de-situation","blog\u002Fwhat-is-a-situation-plan.fr",[287,288,26,22,290,289,294,292,293,985,986,987],"contrôle électrique","plan au sol","Belgique","MK5VPnX4cpSle1v07YI2kXYK-McZrFeOxXk1cdmVufA",{"id":990,"title":991,"articleId":6,"body":992,"category":274,"date":275,"description":1228,"extension":277,"lastUpdated":275,"locale":1229,"meta":1230,"navigation":280,"path":1231,"publishDate":275,"readTime":282,"refreshInterval":283,"seo":1232,"slug":1233,"stem":1234,"tags":1235,"__hash__":1239},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.nl.md","Wat is een situatieschema?",{"type":8,"value":993,"toc":1219},[994,998,1011,1018,1022,1029,1068,1071,1075,1077,1110,1114,1193,1196,1200,1214],[11,995,997],{"id":996},"een-plattegrond-van-uw-elektrische-installatie","Een plattegrond van uw elektrische installatie",[16,999,1000,1001,1003,1004,1006,1007,1010],{},"Het situatieschema (Frans: ",[20,1002,26],{},", Duits: ",[20,1005,290],{},") is een op schaal getekende plattegrond van uw gebouw met de ",[29,1008,1009],{},"fysieke positie"," van alle elektrische componenten — stopcontacten, schakelaars, verlichtingspunten, verdeelborden en kabelroutes.",[16,1012,1013,1014,1017],{},"In tegenstelling tot het eendraadschema toont het situatieschema niet de logische circuithiërarchie, maar ",[29,1015,1016],{},"waar precies"," alles zich bevindt.",[11,1019,1021],{"id":1020},"wat-zegt-het-arei","Wat zegt het AREI?",[16,1023,1024,1025,1028],{},"Volgens AREI Art. 9.1 (Art. 269 in het oude AREI, sinds 2020 Art. 9.1) moet elke elektrische installatie in België over ",[29,1026,1027],{},"twee verplichte tekeningen"," beschikken:",[52,1030,1031,1043],{},[55,1032,1033],{},[58,1034,1035,1037,1040],{},[61,1036,63],{},[61,1038,1039],{},"AREI-artikel",[61,1041,1042],{},"Toont",[71,1044,1045,1056],{},[58,1046,1047,1051,1053],{},[76,1048,1049],{},[29,1050,552],{},[76,1052,83],{},[76,1054,1055],{},"Logische structuur — beschermingstoestellen, kringen, hiërarchie",[58,1057,1058,1063,1065],{},[76,1059,1060],{},[29,1061,1062],{},"Situatieschema",[76,1064,96],{},[76,1066,1067],{},"Fysieke positie — waar alles in het gebouw is geïnstalleerd, incl. locatie van de meterkast en aardingsinstallatie",[16,1069,1070],{},"Beide documenten moeten bij elke elektrische keuring worden voorgelegd. Als er een ontbreekt, wordt de keuring niet goedgekeurd.",[11,1072,1074],{"id":1073},"wat-moet-op-het-situatieschema-staan","Wat moet op het situatieschema staan?",[112,1076,115],{"id":114},[117,1078,1079,1082,1085,1088,1091,1094,1097,1100,1107],{},[120,1080,1081],{},"Op schaal getekende plattegrond van elke verdieping",[120,1083,1084],{},"Positie van alle stopcontacten (enkel, dubbel, geaard)",[120,1086,1087],{},"Positie van alle schakelaars (aan\u002Fuit, wissel, dimmer)",[120,1089,1090],{},"Verlichtingspunten (plafond, wand, buiten)",[120,1092,1093],{},"Verdeelbord en meterpositie",[120,1095,1096],{},"Vast aangesloten toestellen (kookplaat, boiler, laadpaal)",[120,1098,1099],{},"Kabelroutes en installatiezones",[120,1101,1102,1103,1106],{},"Kringreferentienummers (de nummering moet tussen situatieschema en eendraadschema ",[29,1104,1105],{},"identiek"," zijn)",[120,1108,1109],{},"AREI-conforme symbolen (volgens IEC 60617)",[11,1111,1113],{"id":1112},"situatieschema-vs-eendraadschema","Situatieschema vs. eendraadschema",[52,1115,1116,1127],{},[55,1117,1118],{},[58,1119,1120,1123,1125],{},[61,1121,1122],{},"Eigenschap",[61,1124,1062],{},[61,1126,552],{},[71,1128,1129,1140,1151,1161,1172,1183],{},[58,1130,1131,1134,1137],{},[76,1132,1133],{},"Weergave",[76,1135,1136],{},"Fysieke plattegrond",[76,1138,1139],{},"Logisch schakelschema",[58,1141,1142,1145,1148],{},[76,1143,1144],{},"Toont positie?",[76,1146,1147],{},"Ja — exacte locatie",[76,1149,1150],{},"Nee",[58,1152,1153,1156,1158],{},[76,1154,1155],{},"Toont hiërarchie?",[76,1157,1150],{},[76,1159,1160],{},"Ja — van net tot verbruiker",[58,1162,1163,1166,1169],{},[76,1164,1165],{},"Beschermingstoestellen",[76,1167,1168],{},"Alleen positie",[76,1170,1171],{},"Waarden, type, coördinatie",[58,1173,1174,1177,1180],{},[76,1175,1176],{},"Kabelinfo",[76,1178,1179],{},"Routes zichtbaar",[76,1181,1182],{},"Type en doorsnede vermeld",[58,1184,1185,1188,1191],{},[76,1186,1187],{},"Op schaal",[76,1189,1190],{},"Ja (1:50 of 1:100)",[76,1192,1150],{},[16,1194,1195],{},"Beide documenten vullen elkaar aan en zijn beide verplicht.",[11,1197,1199],{"id":1198},"gerelateerde-artikelen","Gerelateerde artikelen",[117,1201,1202,1208],{},[120,1203,1204],{},[246,1205,1207],{"href":1206},"\u002Fblog\u002Feendraadschema-maken","Eendraadschema zelf maken — stap voor stap",[120,1209,1210],{},[246,1211,1213],{"href":1212},"\u002Fblog\u002Fkosten-elektriciteitsplan","Wat kost een elektroplan in België?",[16,1215,1216],{},[246,1217,1218],{"href":260},"Maak nu uw situatieschema met PlanElec — gratis →",{"title":263,"searchDepth":264,"depth":264,"links":1220},[1221,1222,1223,1226,1227],{"id":996,"depth":264,"text":997},{"id":1020,"depth":264,"text":1021},{"id":1073,"depth":264,"text":1074,"children":1224},[1225],{"id":114,"depth":271,"text":115},{"id":1112,"depth":264,"text":1113},{"id":1198,"depth":264,"text":1199},"Het situatieschema toont waar alle elektrische componenten fysiek in uw gebouw zijn geïnstalleerd. Ontdek wat erop moet staan en hoe het verschilt van een eendraadschema.","nl",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.nl",{"title":991,"description":1228},"wat-is-een-situatieschema","blog\u002Fwhat-is-a-situation-plan.nl",[287,288,22,1236,26,290,289,292,293,294,105,1237,1238],"situatieplan","plattegrond","België","JyKuEkAgDLZJc0fuKz2Rfu7UnsREbsAipznzdkwxk0o",1775151659003]