[{"data":1,"prerenderedAt":1528},["ShallowReactive",2],{"blog-teaser-fr":3},[4,917,1224],{"id":5,"title":6,"articleId":7,"body":8,"category":897,"date":898,"description":899,"extension":900,"lastUpdated":898,"locale":901,"meta":902,"navigation":776,"path":903,"publishDate":898,"readTime":904,"refreshInterval":905,"seo":906,"slug":907,"stem":908,"tags":909,"__hash__":916},"blog\u002Fblog\u002Fdraw-situation-plan.fr.md","Dessiner un plan de situation : Guide étape par étape selon le RGIE","draw-situation-plan",{"type":9,"value":10,"toc":875},"minimark",[11,15,24,42,45,48,53,58,61,66,91,95,98,208,210,214,225,404,412,414,418,421,425,458,462,482,486,506,510,513,537,541,561,563,567,574,579,591,596,610,627,629,633,636,662,664,668,759,761,765,833,835,839,860,862],[12,13,6],"h1",{"id":14},"dessiner-un-plan-de-situation-guide-étape-par-étape-selon-le-rgie",[16,17,18,19,23],"p",{},"Le plan de situation (aussi appelé schéma de position) montre ",[20,21,22],"strong",{},"où exactement"," chaque composant électrique se trouve dans votre bâtiment. Avec le schéma unifilaire, c'est l'un des deux documents obligatoires pour toute installation électrique en Belgique — sans lui, le contrôle par l'organisme agréé ne sera pas réussi.",[25,26,27],"blockquote",{},[16,28,29,32,33,37,38,41],{},[20,30,31],{},"En bref :"," Tandis que le schéma unifilaire représente le ",[34,35,36],"em",{},"raccordement logique"," (quel interrupteur commande quel luminaire, via quel circuit), le plan de situation montre la ",[34,39,40],{},"position physique"," de chaque composant sur le plan d'étage.",[16,43,44],{},"Dans ce guide, vous apprendrez comment créer un plan de situation conforme aux normes, étape par étape.",[46,47],"hr",{},[49,50,52],"h2",{"id":51},"étape-1-préparer-le-plan-détage","Étape 1 : Préparer le plan d'étage",[54,55,57],"h3",{"id":56},"dimensions-et-échelle","Dimensions et échelle",[16,59,60],{},"Le plan d'étage constitue la base de votre plan de situation. Vous pouvez le reprendre d'un plan de construction ou le dessiner vous-même.",[16,62,63],{},[20,64,65],{},"Important :",[67,68,69,77,84],"ul",{},[70,71,72,73,76],"li",{},"Utilisez une ",[20,74,75],{},"échelle uniforme"," (courante : 1:50 ou 1:100).",[70,78,79,80,83],{},"Dessinez tous les ",[20,81,82],{},"murs, portes et fenêtres",".",[70,85,86,87,90],{},"Marquez le ",[20,88,89],{},"sens d'ouverture"," des portes (quart de cercle) — cela influence la position des interrupteurs.",[54,92,94],{"id":93},"étiqueter-les-pièces","Étiqueter les pièces",[16,96,97],{},"Identifiez chaque pièce avec sa désignation et idéalement sa surface :",[99,100,101,117],"table",{},[102,103,104],"thead",{},[105,106,107,111,114],"tr",{},[108,109,110],"th",{},"Abréviation",[108,112,113],{},"Pièce",[108,115,116],{},"Surface typique",[118,119,120,132,143,154,165,176,187,198],"tbody",{},[105,121,122,126,129],{},[123,124,125],"td",{},"SÉJ",[123,127,128],{},"Séjour",[123,130,131],{},"25–40 m²",[105,133,134,137,140],{},[123,135,136],{},"CUI",[123,138,139],{},"Cuisine",[123,141,142],{},"10–20 m²",[105,144,145,148,151],{},[123,146,147],{},"CH",[123,149,150],{},"Chambre",[123,152,153],{},"12–18 m²",[105,155,156,159,162],{},[123,157,158],{},"SDB",[123,160,161],{},"Salle de bain",[123,163,164],{},"5–10 m²",[105,166,167,170,173],{},[123,168,169],{},"COU",[123,171,172],{},"Couloir",[123,174,175],{},"5–15 m²",[105,177,178,181,184],{},[123,179,180],{},"GAR",[123,182,183],{},"Garage",[123,185,186],{},"15–30 m²",[105,188,189,192,195],{},[123,190,191],{},"CAV",[123,193,194],{},"Cave",[123,196,197],{},"variable",[105,199,200,203,206],{},[123,201,202],{},"EXT",[123,204,205],{},"Extérieur",[123,207,197],{},[46,209],{},[49,211,213],{"id":212},"étape-2-utiliser-les-symboles-rgie","Étape 2 : Utiliser les symboles RGIE",[16,215,216,217,220,221,224],{},"Le RGIE prescrit dans le ",[20,218,219],{},"Tableau 2.23"," exactement quels symboles doivent être utilisés. Ceux-ci sont basés sur la norme ",[20,222,223],{},"IEC 60617",". Voici les 10 symboles les plus importants pour le plan de situation :",[99,226,227,243],{},[102,228,229],{},[105,230,231,234,237,240],{},[108,232,233],{},"N°",[108,235,236],{},"Symbole",[108,238,239],{},"Description",[108,241,242],{},"Utilisation",[118,244,245,261,276,292,308,324,340,356,372,388],{},[105,246,247,250,253,258],{},[123,248,249],{},"1",[123,251,252],{},"⏚ Demi-cercle",[123,254,255],{},[20,256,257],{},"Prise simple",[123,259,260],{},"Marquer position murale",[105,262,263,266,269,274],{},[123,264,265],{},"2",[123,267,268],{},"⏚⏚ Double demi-cercle",[123,270,271],{},[20,272,273],{},"Prise double",[123,275,260],{},[105,277,278,281,284,289],{},[123,279,280],{},"3",[123,282,283],{},"○ avec croix",[123,285,286],{},[20,287,288],{},"Plafonnier",[123,290,291],{},"Centre de la pièce\u002Fposition",[105,293,294,297,300,305],{},[123,295,296],{},"4",[123,298,299],{},"─○ avec trait",[123,301,302],{},[20,303,304],{},"Applique murale",[123,306,307],{},"Sur le mur",[105,309,310,313,316,321],{},[123,311,312],{},"5",[123,314,315],{},"Symbole interrupteur",[123,317,318],{},[20,319,320],{},"Interrupteur unipolaire",[123,322,323],{},"À côté de la porte (côté ouverture)",[105,325,326,329,332,337],{},[123,327,328],{},"6",[123,330,331],{},"Symbole interrupteur 2 flèches",[123,333,334],{},[20,335,336],{},"Interrupteur sériel",[123,338,339],{},"Commande 2 luminaires",[105,341,342,345,348,353],{},[123,343,344],{},"7",[123,346,347],{},"Symbole interrupteur avec ligne",[123,349,350],{},[20,351,352],{},"Interrupteur va-et-vient",[123,354,355],{},"Deux points, un luminaire",[105,357,358,361,364,369],{},[123,359,360],{},"8",[123,362,363],{},"Rectangle avec éclair",[123,365,366],{},[20,367,368],{},"Tableau de distribution",[123,370,371],{},"Généralement couloir\u002Flocal technique",[105,373,374,377,380,385],{},[123,375,376],{},"9",[123,378,379],{},"⏚ avec PE",[123,381,382],{},[20,383,384],{},"Prise de terre",[123,386,387],{},"Point de mise à la terre",[105,389,390,393,396,401],{},[123,391,392],{},"10",[123,394,395],{},"Cercle avec R",[123,397,398],{},[20,399,400],{},"Détecteur de fumée",[123,402,403],{},"Chaque chambre, couloir, cage d'escalier",[25,405,406],{},[16,407,408,411],{},[20,409,410],{},"Conseil :"," Utilisez exclusivement les symboles RGIE. Des symboles inventés seront refusés lors du contrôle.",[46,413],{},[49,415,417],{"id":416},"étape-3-dessiner-les-composants","Étape 3 : Dessiner les composants",[16,419,420],{},"Placez maintenant les symboles sur le plan d'étage. Les règles suivantes aident au positionnement correct :",[54,422,424],{"id":423},"prises-de-courant","Prises de courant",[67,426,427,434,440,446,452],{},[70,428,429,430,433],{},"Dessiner ",[20,431,432],{},"sur le mur",", à la position réelle.",[70,435,436,439],{},[20,437,438],{},"Cuisine :"," plan de travail minimum 4 prises, dont 2 au-dessus du plan de travail. Prises dédiées pour four, lave-vaisselle, réfrigérateur.",[70,441,442,445],{},[20,443,444],{},"Pièces de vie :"," Min. 1 prise par tranche de 4 m² entamée (recommandation pratique des associations d'installateurs — le RGIE ne prescrit pas de nombre minimum de prises par surface).",[70,447,448,451],{},[20,449,450],{},"Salle de bain :"," Prises basse tension à partir de la zone 2 (uniquement pour les baignoires, avec différentiel 30mA) ou hors zones. Pour les douches, la zone 2 n'existe pas (art. 7.1.3.2 n° 3b, art. 7.1.5.2d).",[70,453,454,457],{},[20,455,456],{},"Extérieur :"," Si une prise extérieure est installée, elle doit être protégée contre les intempéries (IP44) et sécurisée par son propre différentiel 30mA.",[54,459,461],{"id":460},"interrupteurs","Interrupteurs",[67,463,464,470,476],{},[70,465,466,469],{},[20,467,468],{},"À côté de la porte"," du côté de l'ouverture, à environ 105 cm de hauteur (recommandation pratique — le RGIE ne prescrit pas de hauteur spécifique pour les interrupteurs, mais exige qu'ils soient « facilement accessibles »).",[70,471,472,475],{},[20,473,474],{},"Interrupteurs va-et-vient"," pour les pièces à plusieurs entrées ou en début\u002Ffin d'escalier.",[70,477,478,479,83],{},"Reliez les interrupteurs et les luminaires associés par une ",[20,480,481],{},"ligne pointillée",[54,483,485],{"id":484},"points-lumineux","Points lumineux",[67,487,488,494,500],{},[70,489,490,493],{},[20,491,492],{},"Plafonniers"," au centre de la pièce ou à la position prévue.",[70,495,496,499],{},[20,497,498],{},"Appliques murales"," à la position sur le mur.",[70,501,502,503,83],{},"Chaque pièce nécessite au minimum ",[20,504,505],{},"un point lumineux",[54,507,509],{"id":508},"détecteurs-de-fumée","Détecteurs de fumée",[16,511,512],{},"Obligatoires selon la législation belge sur la sécurité incendie (varie selon la région) :",[67,514,515,522,528,534],{},[70,516,517,518,521],{},"En ",[20,519,520],{},"Flandre :"," Obligatoire dans les voies d'évacuation (couloirs, cages d'escalier) ; dans les chambres recommandé, mais pas obligatoire.",[70,523,517,524,527],{},[20,525,526],{},"Wallonie et Bruxelles"," : des réglementations propres s'appliquent.",[70,529,530,533],{},[20,531,532],{},"Couloirs et cages d'escalier"," — au minimum un détecteur de fumée par étage.",[70,535,536],{},"Dans la cuisine optionnel (détecteur de chaleur préféré pour éviter les fausses alarmes).",[54,538,540],{"id":539},"consommateurs-spéciaux","Consommateurs spéciaux",[67,542,543,549,555],{},[70,544,545,548],{},[20,546,547],{},"Borne de recharge"," (véhicule électrique) : garage ou mur extérieur, circuit dédié.",[70,550,551,554],{},[20,552,553],{},"Chauffe-eau\u002FBoiler :"," Circuit dédié, dessiner la position.",[70,556,557,560],{},[20,558,559],{},"Pompe à chaleur\u002FClimatisation :"," Marquer unité extérieure + unité intérieure.",[46,562],{},[49,564,566],{"id":565},"étape-4-attribuer-les-numéros-de-circuits","Étape 4 : Attribuer les numéros de circuits",[16,568,569,570,573],{},"Chaque composant du plan de situation reçoit le ",[20,571,572],{},"même numéro de circuit"," que dans le schéma unifilaire. C'est essentiel pour l'attribution lors du contrôle.",[16,575,576],{},[20,577,578],{},"Comment ça marche :",[580,581,582,585,588],"ol",{},[70,583,584],{},"Numérotez vos circuits dans le schéma unifilaire (1, 2, 3, ...).",[70,586,587],{},"Inscrivez le numéro à côté de chaque composant sur le plan de situation.",[70,589,590],{},"Utilisez une notation uniforme : par ex. « C1 » pour circuit 1 ou simplement « 1 ».",[16,592,593],{},[20,594,595],{},"Exemple :",[67,597,598,601,604,607],{},[70,599,600],{},"Circuit 1 : Éclairage rez-de-chaussée → Tous les luminaires du RDC reçoivent « 1 ».",[70,602,603],{},"Circuit 2 : Prises séjour → Toutes les prises du séjour reçoivent « 2 ».",[70,605,606],{},"Circuit 3 : Prises cuisine → Toutes les prises de cuisine reçoivent « 3 ».",[70,608,609],{},"Circuit 4 : Dédié four → Une prise avec « 4 ».",[25,611,612,621],{},[16,613,614,616,617,620],{},[20,615,65],{}," Les numéros doivent correspondre ",[20,618,619],{},"exactement"," entre le schéma unifilaire et le plan de situation. Les incohérences sont l'une des causes les plus fréquentes de remarques lors du contrôle.",[16,622,623,626],{},[20,624,625],{},"Obligation de documentation :"," Art. 9.1.2 n° 1 (schéma unifilaire) et art. 9.1.2 n° 2 (plan de situation).",[46,628],{},[49,630,632],{"id":631},"étape-5-légende-et-étiquetage","Étape 5 : Légende et étiquetage",[16,634,635],{},"Complétez votre plan avec :",[67,637,638,644,650,656],{},[70,639,640,643],{},[20,641,642],{},"Légende"," avec tous les symboles utilisés et leur signification.",[70,645,646,649],{},[20,647,648],{},"Cartouche"," avec : nom du propriétaire, adresse, date, auteur du plan, échelle.",[70,651,652,655],{},[20,653,654],{},"Flèche nord"," (optionnel, mais utile).",[70,657,658,661],{},[20,659,660],{},"Indication d'étage"," pour les bâtiments à plusieurs niveaux (un plan par étage).",[46,663],{},[49,665,667],{"id":666},"erreurs-fréquentes","Erreurs fréquentes",[99,669,670,683],{},[102,671,672],{},[105,673,674,677,680],{},[108,675,676],{},"Erreur",[108,678,679],{},"Conséquence",[108,681,682],{},"Solution",[118,684,685,696,707,718,728,739,749],{},[105,686,687,690,693],{},[123,688,689],{},"Détecteurs de fumée manquants",[123,691,692],{},"Contrôle non réussi",[123,694,695],{},"Min. 1 par étage dans les voies d'évacuation (varie selon la région)",[105,697,698,701,704],{},[123,699,700],{},"Prise extérieure non conforme",[123,702,703],{},"Remarque, si installée mais non conforme",[123,705,706],{},"Si installée : IP44, différentiel 30mA dédié. L'absence de prise extérieure n'est pas un motif de refus",[105,708,709,712,715],{},[123,710,711],{},"Étiquetage \u002F numéros de circuits manquants",[123,713,714],{},"Remarque",[123,716,717],{},"Numéroter chaque composant",[105,719,720,723,725],{},[123,721,722],{},"Mauvais symboles",[123,724,714],{},[123,726,727],{},"Utiliser uniquement le Tableau 2.23 du RGIE",[105,729,730,733,736],{},[123,731,732],{},"Interrupteur du mauvais côté de la porte",[123,734,735],{},"Non pratique (pas d'infraction RGIE)",[123,737,738],{},"Vérifier le sens d'ouverture",[105,740,741,744,746],{},[123,742,743],{},"Prise salle de bain en zone 0 ou 1",[123,745,692],{},[123,747,748],{},"Prises à partir de la zone 2 (baignoire uniquement) ou hors zones (douche) (art. 7.1.5.2c\u002Fd)",[105,750,751,754,756],{},[123,752,753],{},"Pas de légende",[123,755,714],{},[123,757,758],{},"Joindre un tableau de symboles",[46,760],{},[49,762,764],{"id":763},"checklist-avant-soumission","Checklist avant soumission",[67,766,769,779,785,791,797,803,809,815,821,827],{"className":767},[768],"contains-task-list",[70,770,773,778],{"className":771},[772],"task-list-item",[774,775],"input",{"disabled":776,"type":777},true,"checkbox"," Toutes les pièces étiquetées",[70,780,782,784],{"className":781},[772],[774,783],{"disabled":776,"type":777}," Toutes les prises, interrupteurs, luminaires dessinés",[70,786,788,790],{"className":787},[772],[774,789],{"disabled":776,"type":777}," Détecteurs de fumée dans les voies d'évacuation (min. 1 par étage, varie selon la région)",[70,792,794,796],{"className":793},[772],[774,795],{"disabled":776,"type":777}," Prises extérieures, si installées, conformes (IP44, différentiel 30mA dédié)",[70,798,800,802],{"className":799},[772],[774,801],{"disabled":776,"type":777}," Numéros de circuits sur chaque composant",[70,804,806,808],{"className":805},[772],[774,807],{"disabled":776,"type":777}," Les numéros correspondent au schéma unifilaire",[70,810,812,814],{"className":811},[772],[774,813],{"disabled":776,"type":777}," Symboles RGIE utilisés (Tableau 2.23)",[70,816,818,820],{"className":817},[772],[774,819],{"disabled":776,"type":777}," Légende présente",[70,822,824,826],{"className":823},[772],[774,825],{"disabled":776,"type":777}," Cartouche avec nom, adresse, date",[70,828,830,832],{"className":829},[772],[774,831],{"disabled":776,"type":777}," Un plan par étage",[46,834],{},[49,836,838],{"id":837},"articles-connexes","Articles connexes",[67,840,841,848,854],{},[70,842,843],{},[844,845,847],"a",{"href":846},"\u002Ffr\u002Fblog\u002Fquest-ce-quun-schema-unifilaire","Qu'est-ce qu'un schéma unifilaire ?",[70,849,850],{},[844,851,853],{"href":852},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique",[70,855,856],{},[844,857,859],{"href":858},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique : Conception et dimensionnement",[46,861],{},[16,863,864],{},[34,865,866,867,870,871],{},"Avec ",[20,868,869],{},"PlanElec",", créez votre plan de situation directement à partir du plan d'étage — dessinez les pièces, placez les appareils par glisser-déposer, les symboles RGIE sont utilisés automatiquement. ",[844,872,874],{"href":873},"\u002F","Essayer gratuitement →",{"title":876,"searchDepth":877,"depth":877,"links":878},"",2,[879,884,885,892,893,894,895,896],{"id":51,"depth":877,"text":52,"children":880},[881,883],{"id":56,"depth":882,"text":57},3,{"id":93,"depth":882,"text":94},{"id":212,"depth":877,"text":213},{"id":416,"depth":877,"text":417,"children":886},[887,888,889,890,891],{"id":423,"depth":882,"text":424},{"id":460,"depth":882,"text":461},{"id":484,"depth":882,"text":485},{"id":508,"depth":882,"text":509},{"id":539,"depth":882,"text":540},{"id":565,"depth":877,"text":566},{"id":631,"depth":877,"text":632},{"id":666,"depth":877,"text":667},{"id":763,"depth":877,"text":764},{"id":837,"depth":877,"text":838},"guide","2026-03-30","Guide complet pour créer un plan de situation conforme au RGIE. De la préparation du plan d'étage aux symboles RGIE jusqu'au dessin finalisé.","md","fr",{},"\u002Fblog\u002Fdraw-situation-plan.fr","8 min",12,{"title":6,"description":899},"dessiner-plan-situation-guide","blog\u002Fdraw-situation-plan.fr",[910,911,912,897,913,914,915],"plan de situation","RGIE","symboles","dessin","plan électrique","plan d'étage","Wpc9xEfZ3BkiZ-yjisU3MCnVQpz9GYOIyWWdtvj0PRA",{"id":918,"title":919,"articleId":920,"body":921,"category":1207,"date":1208,"description":1209,"extension":900,"lastUpdated":1208,"locale":901,"meta":1210,"navigation":776,"path":1211,"publishDate":1208,"readTime":1212,"refreshInterval":905,"seo":1213,"slug":1214,"stem":1215,"tags":1216,"__hash__":1223},"blog\u002Fblog\u002Fpreflex-vs-open-wiring.fr.md","Preflex vs. pose libre : Quelle méthode de câblage pour votre projet ?","preflex-vs-open-wiring",{"type":9,"value":922,"toc":1198},[923,927,933,937,940,944,1059,1063,1083,1087,1107,1111,1130,1137,1141,1161,1163,1165,1185,1187],[12,924,926],{"id":925},"preflex-vs-pose-libre-quelle-méthode-convient-à-votre-projet","Preflex vs. pose libre : Quelle méthode convient à votre projet ?",[16,928,929,932],{},[20,930,931],{},"Réponse courte :"," Le Preflex est une gaine préfabriquée avec des câbles déjà tirés — idéal pour la construction neuve, où il est directement coulé dans le béton. La pose libre (par ex. XVB en apparent ou en goulotte) convient mieux aux rénovations, où les gaines sont difficiles à installer après coup.",[49,934,936],{"id":935},"quest-ce-que-le-preflex","Qu'est-ce que le Preflex ?",[16,938,939],{},"Le Preflex est un tube annelé flexible (gaine d'attente) dans lequel les câbles appropriés sont déjà tirés en usine. En Belgique, cette méthode est extrêmement répandue dans la construction neuve : les gaines sont posées pendant la phase de gros œuvre sur la dalle en béton ou dans la chape, puis coulées. Les câbles sont ainsi entièrement protégés et remplaçables ultérieurement si nécessaire.",[49,941,943],{"id":942},"comparaison-preflex-safe-vs-preflex-normal-vs-pose-libre","Comparaison : Preflex Safe vs. Preflex normal vs. pose libre",[99,945,946,962],{},[102,947,948],{},[105,949,950,953,956,959],{},[108,951,952],{},"Critère",[108,954,955],{},"Preflex Safe",[108,957,958],{},"Preflex normal",[108,960,961],{},"Pose libre (XVB)",[118,963,964,980,996,1012,1027,1043],{},[105,965,966,971,974,977],{},[123,967,968],{},[20,969,970],{},"Gaine",[123,972,973],{},"Sans halogène (LSOH)",[123,975,976],{},"PVC standard",[123,978,979],{},"Pas de gaine, câble direct",[105,981,982,987,990,993],{},[123,983,984],{},[20,985,986],{},"Classe CPR",[123,988,989],{},"Cca-s1,d1,a1 (câble dans conduit)",[123,991,992],{},"Eca (câble dans conduit ; la classe CPR se réfère au câble, pas au conduit lui-même)",[123,994,995],{},"XVB avec marquage CPR Cca-s1,d2,a1 (exigé dans certains modes de pose pour les nouvelles installations ; les stocks anciens peuvent encore être classés Eca)",[105,997,998,1003,1006,1009],{},[123,999,1000],{},[20,1001,1002],{},"Application",[123,1004,1005],{},"Neuf, bâtiments publics",[123,1007,1008],{},"Neuf résidentiel",[123,1010,1011],{},"Rénovation, apparent",[105,1013,1014,1019,1022,1024],{},[123,1015,1016],{},[20,1017,1018],{},"Remplacement câble",[123,1020,1021],{},"Oui",[123,1023,1021],{},[123,1025,1026],{},"Non (installation fixe)",[105,1028,1029,1034,1037,1040],{},[123,1030,1031],{},[20,1032,1033],{},"Coût",[123,1035,1036],{},"Le plus élevé",[123,1038,1039],{},"Moyen",[123,1041,1042],{},"Le plus bas",[105,1044,1045,1050,1053,1056],{},[123,1046,1047],{},[20,1048,1049],{},"Conformité RGIE",[123,1051,1052],{},"Toutes applications",[123,1054,1055],{},"Résidentiel autorisé",[123,1057,1058],{},"Toutes applications (si type de câble correct)",[49,1060,1062],{"id":1061},"avantages-du-preflex","Avantages du Preflex",[67,1064,1065,1071,1077],{},[70,1066,1067,1070],{},[20,1068,1069],{},"Installation soignée :"," Pas de câbles visibles, tout est encastré ou coulé.",[70,1072,1073,1076],{},[20,1074,1075],{},"Pérennité :"," Les câbles peuvent être remplacés ou ajoutés ultérieurement sans casser les murs.",[70,1078,1079,1082],{},[20,1080,1081],{},"Protection :"," La gaine protège contre les dommages mécaniques.",[49,1084,1086],{"id":1085},"inconvénients-du-preflex","Inconvénients du Preflex",[67,1088,1089,1095,1101],{},[70,1090,1091,1094],{},[20,1092,1093],{},"Plus cher"," que la pose directe de câbles (matériel + main-d'œuvre).",[70,1096,1097,1100],{},[20,1098,1099],{},"Uniquement en construction neuve\u002Frénovation lourde"," — difficilement installable lors d'une simple rénovation.",[70,1102,1103,1106],{},[20,1104,1105],{},"Rayons de courbure"," à respecter : des courbes trop serrées compliquent le retirage ultérieur.",[49,1108,1110],{"id":1109},"que-dit-le-rgie","Que dit le RGIE ?",[16,1112,1113,1114,1117,1118,1121,1122,1125,1126,1129],{},"Le RGIE ne prescrit pas de méthode d'installation particulière — les deux sont autorisées. Ce qui compte, c'est la ",[20,1115,1116],{},"classe de réaction au feu"," (règlement CPR) : les câbles posés individuellement doivent avoir au minimum ",[20,1119,1120],{},"Eca"," (art. 5.2.7.2). En ",[20,1123,1124],{},"faisceaux, cloisons creuses et cavités constructives",", la classe minimale ",[20,1127,1128],{},"Cca"," est exigée (art. 5.2.7.3, art. 4.3.3.5b). Attention : les murs à ossature bois (fréquents en rénovation) comptent comme cavité constructive !",[16,1131,1132,1133,1136],{},"Le conduit ne doit pas être rempli à plus de ",[20,1134,1135],{},"40 %"," par des câbles (règle d'installation générale selon les règles de l'art), afin de permettre le retirage ultérieur.",[49,1138,1140],{"id":1139},"quelle-méthode-choisir","Quelle méthode choisir ?",[67,1142,1143,1149,1155],{},[70,1144,1145,1148],{},[20,1146,1147],{},"Construction neuve"," → Preflex (Safe pour la meilleure protection incendie)",[70,1150,1151,1154],{},[20,1152,1153],{},"Rénovation"," → Câble XVB en goulotte ou en apparent",[70,1156,1157,1160],{},[20,1158,1159],{},"Rénovation partielle"," → Combinaison possible (nouveaux circuits en Preflex, existants conservés)",[46,1162],{},[49,1164,838],{"id":837},[67,1166,1167,1173,1179],{},[70,1168,1169],{},[844,1170,1172],{"href":1171},"\u002Ffr\u002Fblog\u002Frgie-2026-changements","Que change le RGIE 2026 ?",[70,1174,1175],{},[844,1176,1178],{"href":1177},"\u002Ffr\u002Fblog\u002Fsalle-de-bain-cables-rgie-zones","Électricité salle de bain : Zones et types de câbles",[70,1180,1181],{},[844,1182,1184],{"href":1183},"\u002Ffr\u002Fblog\u002Fancien-rgie-part-8","Ancien bâtiment et RGIE Partie 8",[46,1186],{},[16,1188,1189],{},[34,1190,1191,1192,1194,1195],{},"Planifiez votre installation électrique conforme aux normes avec ",[20,1193,869],{}," — que ce soit en construction neuve avec Preflex ou en rénovation avec pose libre. Notre outil crée automatiquement le schéma unifilaire et le plan de situation adaptés. ",[844,1196,1197],{"href":873},"Commencer gratuitement →",{"title":876,"searchDepth":877,"depth":877,"links":1199},[1200,1201,1202,1203,1204,1205,1206],{"id":935,"depth":877,"text":936},{"id":942,"depth":877,"text":943},{"id":1061,"depth":877,"text":1062},{"id":1085,"depth":877,"text":1086},{"id":1109,"depth":877,"text":1110},{"id":1139,"depth":877,"text":1140},{"id":837,"depth":877,"text":838},"faq","2026-03-27","Comparaison des gaines Preflex et de la pose libre de câbles en Belgique. Avantages, inconvénients et classes de réaction au feu RGIE.",{},"\u002Fblog\u002Fpreflex-vs-open-wiring.fr","3 min",{"title":919,"description":1209},"preflex-vs-pose-libre","blog\u002Fpreflex-vs-open-wiring.fr",[1217,1218,1219,1220,911,1221,1222],"preflex","câblage","construction neuve","rénovation","sécurité incendie","XVB","0E6RS7hErpFqgjK6GK9XE1Lgj-QIWpYerJsUJqPAZRY",{"id":1225,"title":1226,"articleId":1227,"body":1228,"category":1207,"date":1512,"description":1513,"extension":900,"lastUpdated":1512,"locale":901,"meta":1514,"navigation":776,"path":1515,"publishDate":1512,"readTime":1516,"refreshInterval":905,"seo":1517,"slug":1518,"stem":1519,"tags":1520,"__hash__":1527},"blog\u002Fblog\u002Frcd-type-a-vs-b.fr.md","Différentiel Type A vs. Type B : Quand ai-je besoin de quel type ?","rcd-type-a-vs-b",{"type":9,"value":1229,"toc":1503},[1230,1233,1239,1243,1343,1347,1354,1374,1378,1381,1401,1405,1451,1455,1458,1478,1481,1485,1492,1494],[12,1231,1226],{"id":1232},"différentiel-type-a-vs-type-b-quand-ai-je-besoin-de-quel-type",[16,1234,1235,1238],{},[20,1236,1237],{},"Le RGIE prescrit au minimum un différentiel (DDR) de Type A."," Le Type B est requis lorsque des courants de défaut continus peuvent apparaître — typiquement avec des bornes de recharge sans détecteur de courant de défaut DC intégré ou des pompes à chaleur avec variateur de fréquence. Le choix du bon type de DDR est déterminant pour la sécurité et la conformité au contrôle.",[49,1240,1242],{"id":1241},"aperçu-de-tous-les-types-de-ddr","Aperçu de tous les types de DDR",[99,1244,1245,1261],{},[102,1246,1247],{},[105,1248,1249,1252,1255,1258],{},[108,1250,1251],{},"Type",[108,1253,1254],{},"Détecte",[108,1256,1257],{},"Domaine d'application",[108,1259,1260],{},"Prix (env.)",[118,1262,1263,1279,1295,1311,1327],{},[105,1264,1265,1270,1273,1276],{},[123,1266,1267],{},[20,1268,1269],{},"AC",[123,1271,1272],{},"Uniquement les courants de défaut alternatifs purs",[123,1274,1275],{},"Obsolète, plus autorisé pour les nouvelles installations",[123,1277,1278],{},"~25–40 €",[105,1280,1281,1286,1289,1292],{},[123,1282,1283],{},[20,1284,1285],{},"A",[123,1287,1288],{},"Alternatifs + courants de défaut continus pulsés",[123,1290,1291],{},"Standard pour usage domestique",[123,1293,1294],{},"~40–60 €",[105,1296,1297,1302,1305,1308],{},[123,1298,1299],{},[20,1300,1301],{},"A-SI",[123,1303,1304],{},"Comme Type A, sélectif (temporisé)",[123,1306,1307],{},"DDR principal (300 mA), évite le déclenchement en cascade",[123,1309,1310],{},"~80–120 €",[105,1312,1313,1318,1321,1324],{},[123,1314,1315],{},[20,1316,1317],{},"B",[123,1319,1320],{},"Tous les courants de défaut y compris continu lisse",[123,1322,1323],{},"Borne de recharge, pompe à chaleur avec onduleur",[123,1325,1326],{},"~150–250 €",[105,1328,1329,1334,1337,1340],{},[123,1330,1331],{},[20,1332,1333],{},"F",[123,1335,1336],{},"Comme A + courants de défaut à fréquence variable",[123,1338,1339],{},"Entraînements à fréquence variable (moteurs)",[123,1341,1342],{},"~100–180 €",[49,1344,1346],{"id":1345},"quand-le-type-b-est-il-requis","Quand le Type B est-il requis ?",[16,1348,1349,1350,1353],{},"Le Type B est nécessaire lorsqu'un appareil peut générer des ",[20,1351,1352],{},"courants de défaut continus lisses",". Cela concerne principalement :",[67,1355,1356,1362,1368],{},[70,1357,1358,1361],{},[20,1359,1360],{},"Borne de recharge sans détecteur de courant de défaut DC intégré :"," Les bornes simples sans détection DC 6 mA nécessitent un DDR Type B",[70,1363,1364,1367],{},[20,1365,1366],{},"Pompe à chaleur avec onduleur (variateur de fréquence) :"," Le variateur peut générer des courants de défaut DC",[70,1369,1370,1373],{},[20,1371,1372],{},"Onduleur PV sans transformateur :"," Les onduleurs sans transformateur peuvent injecter des composantes DC dans le réseau",[49,1375,1377],{"id":1376},"quand-le-type-a-suffit-il","Quand le Type A suffit-il ?",[16,1379,1380],{},"Le Type A est suffisant pour :",[67,1382,1383,1389,1395],{},[70,1384,1385,1388],{},[20,1386,1387],{},"Borne de recharge AVEC détecteur de courant de défaut DC intégré (6 mA) :"," Le RGIE (Art. 7.22.4) prescrit un DDR Type B ou équivalent (p.ex. Type A + RDC-DD) pour les bornes de recharge. Un simple Type A seul ne suffit pas pour une borne — la borne doit disposer d'un capteur DC 6 mA intégré qui détecte les courants de défaut DC à partir de 6 mA et interrompt la charge",[70,1390,1391,1394],{},[20,1392,1393],{},"Appareils ménagers normaux :"," Machine à laver, lave-vaisselle, plaque de cuisson, éclairage",[70,1396,1397,1400],{},[20,1398,1399],{},"Circuits prises de courant :"," DDR standard 30 mA Type A",[49,1402,1404],{"id":1403},"exigences-rgie","Exigences RGIE",[99,1406,1407,1417],{},[102,1408,1409],{},[105,1410,1411,1414],{},[108,1412,1413],{},"Article RGIE",[108,1415,1416],{},"Exigence",[118,1418,1419,1427,1435,1443],{},[105,1420,1421,1424],{},[123,1422,1423],{},"Art. 4.2.4.3",[123,1425,1426],{},"Le DDR est obligatoire pour chaque circuit (système TT)",[105,1428,1429,1432],{},[123,1430,1431],{},"Art. 4.2.4.3_b",[123,1433,1434],{},"Maximum 8 circuits départ par DDR 30 mA",[105,1436,1437,1440],{},[123,1438,1439],{},"Art. 5.3.5.3_a",[123,1441,1442],{},"Dispositifs de protection à courant différentiel résiduel dans les installations domestiques au minimum Type A ; au point d'alimentation au minimum 40 A de courant nominal",[105,1444,1445,1448],{},[123,1446,1447],{},"Art. 7.22",[123,1449,1450],{},"Borne de recharge : circuit dédié avec DDR approprié",[49,1452,1454],{"id":1453},"respecter-la-sélectivité","Respecter la sélectivité",[16,1456,1457],{},"Pour une sélectivité correcte, l'installation doit être structurée comme suit :",[580,1459,1460,1466,1472],{},[70,1461,1462,1465],{},[20,1463,1464],{},"DDR principal :"," 300 mA, Type A-SI (sélectif, temporisé)",[70,1467,1468,1471],{},[20,1469,1470],{},"DDR de groupe :"," 30 mA, Type A (pour les circuits normaux)",[70,1473,1474,1477],{},[20,1475,1476],{},"DDR spécial :"," 30 mA, Type B (pour borne de recharge\u002Fpompe à chaleur, si pas de détecteur DC intégré)",[16,1479,1480],{},"Ainsi, en cas de défaut, seul le DDR de groupe concerné déclenche, pas le DDR principal — le reste de l'installation reste en service.",[49,1482,1484],{"id":1483},"différence-de-prix-et-recommandation","Différence de prix et recommandation",[16,1486,1487,1488,1491],{},"La différence de prix entre Type A (~40–60 €) et Type B (~150–250 €) est considérable. Vérifiez donc toujours d'abord si votre borne de recharge ou pompe à chaleur dispose d'un ",[20,1489,1490],{},"détecteur de courant de défaut DC intégré",". Si oui, un DDR Type A moins coûteux suffit. La documentation du fabricant fournit cette information.",[49,1493,838],{"id":837},[16,1495,1496,1497,1502],{},"Planifiez vos dispositifs de protection conforme aux normes avec ",[844,1498,869],{"href":1499,"rel":1500},"https:\u002F\u002Fwww.planelec.be",[1501],"nofollow"," — recommandation automatique du type de DDR incluse.",{"title":876,"searchDepth":877,"depth":877,"links":1504},[1505,1506,1507,1508,1509,1510,1511],{"id":1241,"depth":877,"text":1242},{"id":1345,"depth":877,"text":1346},{"id":1376,"depth":877,"text":1377},{"id":1403,"depth":877,"text":1404},{"id":1453,"depth":877,"text":1454},{"id":1483,"depth":877,"text":1484},{"id":837,"depth":877,"text":838},"2026-03-25","Comparaison de tous les types de DDR (AC, A, A-SI, B, F) pour les installations électriques belges selon le RGIE.",{},"\u002Fblog\u002Frcd-type-a-vs-b.fr","5 min",{"title":1226,"description":1513},"differentiel-type-a-vs-type-b","blog\u002Frcd-type-a-vs-b.fr",[1521,1522,1523,1524,1525,1526],"differentiel","ddr","type-a","type-b","rgie","borne-de-recharge","qUwiraQ4SIZ55Tm-Ko-QKEzigrcalWUo3Zw4cVE6MeA",1775151655476]