[{"data":1,"prerenderedAt":971},["ShallowReactive",2],{"blog-post-fr-30ma-ddr-par-prise":3,"blog-alternates-30ma-rcd-per-socket":234},{"id":4,"title":5,"articleId":6,"body":7,"category":206,"date":207,"description":208,"extension":209,"lastUpdated":207,"locale":210,"meta":211,"navigation":212,"path":213,"publishDate":207,"readTime":214,"refreshInterval":215,"seo":216,"slug":217,"stem":218,"tags":219,"__hash__":233},"blog\u002Fblog\u002F30ma-rcd-per-socket.fr.md","Ai-je besoin d'un différentiel 30mA par prise ?","30ma-rcd-per-socket",{"type":8,"value":9,"toc":195},"minimark",[10,15,28,32,35,84,89,135,139,142,158,161,170,174,189],[11,12,14],"h2",{"id":13},"non-mais-chaque-circuit-de-prises-en-a-besoin","Non — mais chaque circuit de prises en a besoin",[16,17,18,19,23,24,27],"p",{},"Une idée reçue courante : il n'est ",[20,21,22],"strong",{},"pas"," nécessaire d'installer un différentiel 30mA dédié pour chaque prise individuelle. L'exigence du RGIE porte sur les ",[20,25,26],{},"circuits",", pas sur les points de connexion individuels. Un seul différentiel 30mA protège généralement plusieurs prises raccordées au même circuit.",[11,29,31],{"id":30},"que-dit-le-rgie","Que dit le RGIE ?",[16,33,34],{},"Le RGIE (Règlement Général sur les Installations Électriques) précise dans plusieurs articles quand une protection différentielle 30mA est obligatoire :",[36,37,38,51],"table",{},[39,40,41],"thead",{},[42,43,44,48],"tr",{},[45,46,47],"th",{},"Article",[45,49,50],{},"Exigence",[52,53,54,65,74],"tbody",{},[42,55,56,62],{},[57,58,59],"td",{},[20,60,61],{},"Art. 4.2.4.3_b",[57,63,64],{},"Tous les circuits de prises ≤ 32A doivent être protégés par un différentiel 30mA",[42,66,67,71],{},[57,68,69],{},[20,70,61],{},[57,72,73],{},"Maximum 8 circuits départ par différentiel",[42,75,76,81],{},[57,77,78],{},[20,79,80],{},"Art. 7.1.4.3",[57,82,83],{},"Dans la salle de bain, la protection 30mA est toujours obligatoire (Chapitre 7.1 pour les locaux avec baignoire\u002Fdouche)",[85,86,88],"h3",{"id":87},"limites-essentielles","Limites essentielles",[36,90,91,101],{},[39,92,93],{},[42,94,95,98],{},[45,96,97],{},"Critère",[45,99,100],{},"Limite",[52,102,103,111,119,127],{},[42,104,105,108],{},[57,106,107],{},"Max. circuits par différentiel 30mA",[57,109,110],{},"8",[42,112,113,116],{},[57,114,115],{},"Max. prises par circuit",[57,117,118],{},"8 (obligatoire selon Art. 5.3.5.2_b)",[42,120,121,124],{},[57,122,123],{},"Courant nominal circuit prises",[57,125,126],{},"16A ou 20A",[42,128,129,132],{},[57,130,131],{},"Section min. du câble prises",[57,133,134],{},"min. 2,5 mm² (indépendamment de la protection 16 A ou 20 A ; pour l'éclairage 1,5 mm² suffit à 16 A)",[11,136,138],{"id":137},"exemple-pratique","Exemple pratique",[16,140,141],{},"Une maison unifamiliale typique possède par exemple 6 circuits de prises. Ceux-ci peuvent être répartis sur deux différentiels 30mA :",[143,144,145,152],"ul",{},[146,147,148,151],"li",{},[20,149,150],{},"Diff 1"," (30mA, Type A) : prises salon, couloir, chambre 1 — 3 circuits",[146,153,154,157],{},[20,155,156],{},"Diff 2"," (30mA, Type A) : prises cuisine, chambre 2, bureau — 3 circuits",[16,159,160],{},"Ainsi, si un différentiel se déclenche, toute la maison ne perd pas le courant, et vous restez sous la limite de 8 circuits par différentiel.",[162,163,164],"blockquote",{},[16,165,166,169],{},[20,167,168],{},"Attention"," : Pour les salles de bain (Art. 7.1.4.3), le RGIE prescrit des mesures de protection particulières. Dans les installations domestiques (Art. 4.2.4.3_b), les circuits des locaux avec baignoire et\u002Fou douche doivent être protégés par un dispositif de protection à courant différentiel résiduel à haute sensibilité (30 mA).",[11,171,173],{"id":172},"articles-connexes","Articles connexes",[143,175,176,183],{},[146,177,178],{},[179,180,182],"a",{"href":181},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire — étape par étape",[146,184,185],{},[179,186,188],{"href":187},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique — ce qu'il faut savoir",[16,190,191],{},[179,192,194],{"href":193},"\u002F","Créez votre schéma unifilaire conforme RGIE — gratuit →",{"title":196,"searchDepth":197,"depth":197,"links":198},"",2,[199,200,204,205],{"id":13,"depth":197,"text":14},{"id":30,"depth":197,"text":31,"children":201},[202],{"id":87,"depth":203,"text":88},3,{"id":137,"depth":197,"text":138},{"id":172,"depth":197,"text":173},"faq","2026-03-04","Non — mais par circuit. Découvrez ce que le RGIE exige et quand un différentiel 30mA est obligatoire.","md","fr",{},true,"\u002Fblog\u002F30ma-rcd-per-socket.fr","3 min",12,{"title":5,"description":208},"30ma-ddr-par-prise","blog\u002F30ma-rcd-per-socket.fr",[220,221,222,223,224,225,226,227,228,229,230,231,232],"AREI","RGIE","différentiel","disjoncteur différentiel","30mA","prise","circuit","contrôle électrique","installation électrique","Belgique","schéma unifilaire","eendraadschema","plan de situation","goheoc8Oj_Pwnf4dIyIzxbv3_fCLcVWgYxvWvuPG0tU",[235,435,639,777],{"id":236,"title":237,"articleId":6,"body":238,"category":206,"date":207,"description":415,"extension":209,"lastUpdated":207,"locale":416,"meta":417,"navigation":212,"path":418,"publishDate":207,"readTime":214,"refreshInterval":215,"seo":419,"slug":420,"stem":421,"tags":422,"__hash__":434},"blog\u002Fblog\u002F30ma-rcd-per-socket.de.md","Brauche ich einen 30mA FI-Schalter für jede Steckdose?",{"type":8,"value":239,"toc":407},[240,244,255,259,262,303,307,352,356,359,373,376,384,388,402],[11,241,243],{"id":242},"nein-aber-jeder-steckdosen-stromkreis-braucht-einen","Nein — aber jeder Steckdosen-Stromkreis braucht einen",[16,245,246,247,250,251,254],{},"Ein häufiges Missverständnis: Man braucht ",[20,248,249],{},"nicht"," für jede einzelne Steckdose einen eigenen FI-Schutzschalter (Differentieel). Die AREI-Vorschrift bezieht sich auf ",[20,252,253],{},"Stromkreise",", nicht auf einzelne Anschlusspunkte. Ein 30mA-FI-Schutzschalter schützt in der Regel mehrere Steckdosen, die am selben Stromkreis angeschlossen sind.",[11,256,258],{"id":257},"was-sagt-das-arei","Was sagt das AREI?",[16,260,261],{},"Das AREI (Allgemeine Reglementierung der Elektrischen Installationen) legt in mehreren Artikeln fest, wann ein 30mA-Differentialschutz Pflicht ist:",[36,263,264,274],{},[39,265,266],{},[42,267,268,271],{},[45,269,270],{},"Artikel",[45,272,273],{},"Vorschrift",[52,275,276,285,294],{},[42,277,278,282],{},[57,279,280],{},[20,281,61],{},[57,283,284],{},"Alle Steckdosenstromkreise ≤ 32A müssen durch einen 30mA-FI geschützt sein",[42,286,287,291],{},[57,288,289],{},[20,290,61],{},[57,292,293],{},"Maximal 8 Endstromkreise pro FI-Schutzschalter",[42,295,296,300],{},[57,297,298],{},[20,299,80],{},[57,301,302],{},"Im Badezimmer ist 30mA-Schutz immer Pflicht (Kapitel 7.1 für Räumlichkeiten mit Badewanne\u002FDusche)",[85,304,306],{"id":305},"grenzwerte-im-überblick","Grenzwerte im Überblick",[36,308,309,319],{},[39,310,311],{},[42,312,313,316],{},[45,314,315],{},"Kriterium",[45,317,318],{},"Grenzwert",[52,320,321,328,336,344],{},[42,322,323,326],{},[57,324,325],{},"Max. Stromkreise pro 30mA-FI",[57,327,110],{},[42,329,330,333],{},[57,331,332],{},"Max. Steckdosen pro Stromkreis",[57,334,335],{},"8 (Pflicht gemäß Art. 5.3.5.2_b)",[42,337,338,341],{},[57,339,340],{},"Nennstrom Steckdosen-Stromkreis",[57,342,343],{},"16A oder 20A",[42,345,346,349],{},[57,347,348],{},"Kabelquerschnitt Steckdosen",[57,350,351],{},"min. 2,5 mm² (unabhängig ob 16 A oder 20 A Absicherung; für Beleuchtung reicht 1,5 mm² bei 16 A)",[11,353,355],{"id":354},"praxisbeispiel","Praxisbeispiel",[16,357,358],{},"Ein typisches Einfamilienhaus hat z.B. 6 Steckdosen-Stromkreise. Diese können auf zwei 30mA-FI-Schutzschalter aufgeteilt werden:",[143,360,361,367],{},[146,362,363,366],{},[20,364,365],{},"FI 1"," (30mA, Typ A): Steckdosen Wohnzimmer, Flur, Schlafzimmer 1 — 3 Stromkreise",[146,368,369,372],{},[20,370,371],{},"FI 2"," (30mA, Typ A): Steckdosen Küche, Schlafzimmer 2, Büro — 3 Stromkreise",[16,374,375],{},"So bleibt bei einer Auslösung nicht das ganze Haus stromlos, und Sie bleiben unter dem Limit von 8 Stromkreisen pro FI.",[162,377,378],{},[16,379,380,383],{},[20,381,382],{},"Achtung",": Für Badezimmer (Art. 7.1.4.3) schreibt das AREI besondere Schutzmaßnahmen vor. In hauswirtschaftlichen Anlagen (Art. 4.2.4.3_b) müssen die Stromkreise von Räumlichkeiten mit Badewanne und\u002Foder Dusche über eine Differenzstrom-Schutzeinrichtung mit hoher Empfindlichkeit (30 mA) geschützt sein.",[11,385,387],{"id":386},"verwandte-artikel","Verwandte Artikel",[143,389,390,396],{},[146,391,392],{},[179,393,395],{"href":394},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema selbst erstellen — Schritt für Schritt",[146,397,398],{},[179,399,401],{"href":400},"\u002Fde\u002Fblog\u002Felektrische-abnahme","Elektrische Abnahme in Belgien — was Sie wissen müssen",[16,403,404],{},[179,405,406],{"href":193},"Erstellen Sie jetzt Ihr AREI-konformes Eindrahtschema — kostenlos →",{"title":196,"searchDepth":197,"depth":197,"links":408},[409,410,413,414],{"id":242,"depth":197,"text":243},{"id":257,"depth":197,"text":258,"children":411},[412],{"id":305,"depth":203,"text":306},{"id":354,"depth":197,"text":355},{"id":386,"depth":197,"text":387},"Nein — aber pro Stromkreis. Erfahren Sie, was das AREI vorschreibt und wann ein 30mA FI-Schutzschalter Pflicht ist.","de",{},"\u002Fblog\u002F30ma-rcd-per-socket.de",{"title":237,"description":415},"30ma-fi-pro-steckdose","blog\u002F30ma-rcd-per-socket.de",[220,221,423,424,425,224,426,427,428,429,430,431,432,433],"FI-Schutzschalter","Fehlerstromschutzschalter","Differentialschutz","Steckdose","Stromkreis","Stromabnahme","Keuring","elektrische Installation","Belgien","Eindrahtschema","Situationsplan","FBz6gwdWYwP3azGuRlL6GSBCl6r-h02KTYDPKcWahh8",{"id":436,"title":437,"articleId":6,"body":438,"category":206,"date":207,"description":621,"extension":209,"lastUpdated":207,"locale":622,"meta":623,"navigation":212,"path":624,"publishDate":207,"readTime":214,"refreshInterval":215,"seo":625,"slug":6,"stem":626,"tags":627,"__hash__":638},"blog\u002Fblog\u002F30ma-rcd-per-socket.en.md","Do I Need a 30mA RCD for Every Socket?",{"type":8,"value":439,"toc":613},[440,444,462,466,469,509,513,558,562,565,579,582,590,594,608],[11,441,443],{"id":442},"no-but-every-socket-circuit-needs-one","No — but every socket circuit needs one",[16,445,446,447,450,451,454,455,458,459,461],{},"A common misconception: you do ",[20,448,449],{},"not"," need a dedicated 30mA RCD (residual-current device, or ",[452,453,222],"em",{}," \u002F ",[452,456,457],{},"differentieelschakelaar",") for each individual socket. The AREI\u002FRGIE requirement applies to ",[20,460,26],{},", not individual connection points. A single 30mA RCD typically protects multiple sockets connected to the same circuit.",[11,463,465],{"id":464},"what-does-the-arei-say","What does the AREI say?",[16,467,468],{},"The AREI (General Regulations on Electrical Installations) specifies in several articles when 30mA differential protection is mandatory:",[36,470,471,480],{},[39,472,473],{},[42,474,475,477],{},[45,476,47],{},[45,478,479],{},"Requirement",[52,481,482,491,500],{},[42,483,484,488],{},[57,485,486],{},[20,487,61],{},[57,489,490],{},"All socket circuits ≤ 32A must be protected by a 30mA RCD",[42,492,493,497],{},[57,494,495],{},[20,496,61],{},[57,498,499],{},"Maximum 8 final circuits per RCD",[42,501,502,506],{},[57,503,504],{},[20,505,80],{},[57,507,508],{},"In bathrooms (rooms with bathtub\u002Fshower), 30mA protection is always mandatory (Chapter 7.1)",[85,510,512],{"id":511},"key-limits-at-a-glance","Key limits at a glance",[36,514,515,525],{},[39,516,517],{},[42,518,519,522],{},[45,520,521],{},"Criterion",[45,523,524],{},"Limit",[52,526,527,534,542,550],{},[42,528,529,532],{},[57,530,531],{},"Max. circuits per 30mA RCD",[57,533,110],{},[42,535,536,539],{},[57,537,538],{},"Max. sockets per circuit",[57,540,541],{},"8 (mandatory per Art. 5.3.5.2_b)",[42,543,544,547],{},[57,545,546],{},"Rated current for socket circuits",[57,548,549],{},"16A or 20A",[42,551,552,555],{},[57,553,554],{},"Min. cable cross-section at 16A",[57,556,557],{},"2.5 mm²",[11,559,561],{"id":560},"practical-example","Practical example",[16,563,564],{},"A typical single-family home might have 6 socket circuits. These can be split across two 30mA RCDs:",[143,566,567,573],{},[146,568,569,572],{},[20,570,571],{},"RCD 1"," (30mA, Type A): Living room, hallway, bedroom 1 sockets — 3 circuits",[146,574,575,578],{},[20,576,577],{},"RCD 2"," (30mA, Type A): Kitchen, bedroom 2, office sockets — 3 circuits",[16,580,581],{},"This way, if one RCD trips, the entire house doesn't lose power, and you stay within the 8-circuit limit per RCD.",[162,583,584],{},[16,585,586,589],{},[20,587,588],{},"Warning",": For bathrooms (Art. 7.1.4.3), the AREI prescribes special protective measures. In residential installations (Art. 4.2.4.3_b), circuits in rooms with a bathtub and\u002For shower must be protected by a high-sensitivity residual-current device (30 mA).",[11,591,593],{"id":592},"related-articles","Related articles",[143,595,596,602],{},[146,597,598],{},[179,599,601],{"href":600},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","How to create a single-line diagram — step by step",[146,603,604],{},[179,605,607],{"href":606},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical inspection in Belgium — what you need to know",[16,609,610],{},[179,611,612],{"href":193},"Create your AREI-compliant single-line diagram now — free →",{"title":196,"searchDepth":197,"depth":197,"links":614},[615,616,619,620],{"id":442,"depth":197,"text":443},{"id":464,"depth":197,"text":465,"children":617},[618],{"id":511,"depth":203,"text":512},{"id":560,"depth":197,"text":561},{"id":592,"depth":197,"text":593},"No — but you need one per circuit. Learn what the AREI\u002FRGIE requires and when a 30mA residual-current device is mandatory.","en",{},"\u002Fblog\u002F30ma-rcd-per-socket.en",{"title":437,"description":621},"blog\u002F30ma-rcd-per-socket.en",[220,221,628,629,630,224,631,226,632,633,634,635,636,231,432,230,637],"RCD","residual current device","differential switch","socket","electrical inspection","keuring","electrical installation","Belgium","single-line diagram","situation plan","Z1gmDdIuGQhS2DqpCcllYFYghTzCgCj6Sx7DNWe6aTI",{"id":4,"title":5,"articleId":6,"body":640,"category":206,"date":207,"description":208,"extension":209,"lastUpdated":207,"locale":210,"meta":774,"navigation":212,"path":213,"publishDate":207,"readTime":214,"refreshInterval":215,"seo":775,"slug":217,"stem":218,"tags":776,"__hash__":233},{"type":8,"value":641,"toc":766},[642,644,650,652,654,690,692,728,730,732,742,744,750,752,762],[11,643,14],{"id":13},[16,645,18,646,23,648,27],{},[20,647,22],{},[20,649,26],{},[11,651,31],{"id":30},[16,653,34],{},[36,655,656,664],{},[39,657,658],{},[42,659,660,662],{},[45,661,47],{},[45,663,50],{},[52,665,666,674,682],{},[42,667,668,672],{},[57,669,670],{},[20,671,61],{},[57,673,64],{},[42,675,676,680],{},[57,677,678],{},[20,679,61],{},[57,681,73],{},[42,683,684,688],{},[57,685,686],{},[20,687,80],{},[57,689,83],{},[85,691,88],{"id":87},[36,693,694,702],{},[39,695,696],{},[42,697,698,700],{},[45,699,97],{},[45,701,100],{},[52,703,704,710,716,722],{},[42,705,706,708],{},[57,707,107],{},[57,709,110],{},[42,711,712,714],{},[57,713,115],{},[57,715,118],{},[42,717,718,720],{},[57,719,123],{},[57,721,126],{},[42,723,724,726],{},[57,725,131],{},[57,727,134],{},[11,729,138],{"id":137},[16,731,141],{},[143,733,734,738],{},[146,735,736,151],{},[20,737,150],{},[146,739,740,157],{},[20,741,156],{},[16,743,160],{},[162,745,746],{},[16,747,748,169],{},[20,749,168],{},[11,751,173],{"id":172},[143,753,754,758],{},[146,755,756],{},[179,757,182],{"href":181},[146,759,760],{},[179,761,188],{"href":187},[16,763,764],{},[179,765,194],{"href":193},{"title":196,"searchDepth":197,"depth":197,"links":767},[768,769,772,773],{"id":13,"depth":197,"text":14},{"id":30,"depth":197,"text":31,"children":770},[771],{"id":87,"depth":203,"text":88},{"id":137,"depth":197,"text":138},{"id":172,"depth":197,"text":173},{},{"title":5,"description":208},[220,221,222,223,224,225,226,227,228,229,230,231,232],{"id":778,"title":779,"articleId":6,"body":780,"category":206,"date":207,"description":954,"extension":209,"lastUpdated":207,"locale":955,"meta":956,"navigation":212,"path":957,"publishDate":207,"readTime":214,"refreshInterval":215,"seo":958,"slug":959,"stem":960,"tags":961,"__hash__":970},"blog\u002Fblog\u002F30ma-rcd-per-socket.nl.md","Heb ik een 30mA differentieel nodig per stopcontact?",{"type":8,"value":781,"toc":946},[782,786,797,801,804,844,848,893,897,900,912,915,923,927,941],[11,783,785],{"id":784},"nee-maar-elke-stopcontactkring-heeft-er-wel-een-nodig","Nee — maar elke stopcontactkring heeft er wel een nodig",[16,787,788,789,792,793,796],{},"Een veelvoorkomend misverstand: u hebt ",[20,790,791],{},"niet"," voor elk afzonderlijk stopcontact een aparte 30mA differentieel nodig. De AREI-vereiste heeft betrekking op ",[20,794,795],{},"stroomkringen",", niet op individuele aansluitpunten. Eén 30mA differentieelschakelaar beschermt doorgaans meerdere stopcontacten die op dezelfde stroomkring zijn aangesloten.",[11,798,800],{"id":799},"wat-zegt-het-arei","Wat zegt het AREI?",[16,802,803],{},"Het AREI (Algemeen Reglement op de Elektrische Installaties) bepaalt in meerdere artikelen wanneer een 30mA differentieelbescherming verplicht is:",[36,805,806,815],{},[39,807,808],{},[42,809,810,812],{},[45,811,270],{},[45,813,814],{},"Vereiste",[52,816,817,826,835],{},[42,818,819,823],{},[57,820,821],{},[20,822,61],{},[57,824,825],{},"Alle stopcontactkringen ≤ 32A moeten beschermd zijn door een 30mA differentieel",[42,827,828,832],{},[57,829,830],{},[20,831,61],{},[57,833,834],{},"Maximaal 8 vertrekkende kringen per differentieel",[42,836,837,841],{},[57,838,839],{},[20,840,80],{},[57,842,843],{},"In de badkamer is 30mA-bescherming altijd verplicht (Hoofdstuk 7.1 voor ruimtes met bad\u002Fdouche)",[85,845,847],{"id":846},"belangrijkste-limieten","Belangrijkste limieten",[36,849,850,860],{},[39,851,852],{},[42,853,854,857],{},[45,855,856],{},"Criterium",[45,858,859],{},"Limiet",[52,861,862,869,877,885],{},[42,863,864,867],{},[57,865,866],{},"Max. kringen per 30mA differentieel",[57,868,110],{},[42,870,871,874],{},[57,872,873],{},"Max. stopcontacten per kring",[57,875,876],{},"8 (verplicht volgens Art. 5.3.5.2_b)",[42,878,879,882],{},[57,880,881],{},"Nominale stroom stopcontactkring",[57,883,884],{},"16A of 20A",[42,886,887,890],{},[57,888,889],{},"Min. kabeldoorsnede stopcontacten",[57,891,892],{},"min. 2,5 mm² (ongeacht 16 A of 20 A beveiliging; voor verlichting volstaat 1,5 mm² bij 16 A)",[11,894,896],{"id":895},"praktijkvoorbeeld","Praktijkvoorbeeld",[16,898,899],{},"Een typische eengezinswoning heeft bijvoorbeeld 6 stopcontactkringen. Deze kunnen over twee 30mA differentieelschakelaars worden verdeeld:",[143,901,902,907],{},[146,903,904,906],{},[20,905,150],{}," (30mA, Type A): stopcontacten woonkamer, gang, slaapkamer 1 — 3 kringen",[146,908,909,911],{},[20,910,156],{}," (30mA, Type A): stopcontacten keuken, slaapkamer 2, bureau — 3 kringen",[16,913,914],{},"Zo valt niet het hele huis zonder stroom als één differentieel uitschakelt, en u blijft onder de limiet van 8 kringen per differentieel.",[162,916,917],{},[16,918,919,922],{},[20,920,921],{},"Let op",": Voor badkamers (Art. 7.1.4.3) schrijft het AREI bijzondere beschermingsmaatregelen voor. In huishoudelijke installaties (Art. 4.2.4.3_b) moeten de kringen van ruimtes met bad en\u002Fof douche beschermd zijn door een differentieelstroombeveiliging met hoge gevoeligheid (30 mA).",[11,924,926],{"id":925},"gerelateerde-artikelen","Gerelateerde artikelen",[143,928,929,935],{},[146,930,931],{},[179,932,934],{"href":933},"\u002Fblog\u002Feendraadschema-maken","Eendraadschema zelf maken — stap voor stap",[146,936,937],{},[179,938,940],{"href":939},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België — wat u moet weten",[16,942,943],{},[179,944,945],{"href":193},"Maak nu uw AREI-conform eendraadschema — gratis →",{"title":196,"searchDepth":197,"depth":197,"links":947},[948,949,952,953],{"id":784,"depth":197,"text":785},{"id":799,"depth":197,"text":800,"children":950},[951],{"id":846,"depth":203,"text":847},{"id":895,"depth":197,"text":896},{"id":925,"depth":197,"text":926},"Nee — maar per stroomkring wel. Ontdek wat het AREI voorschrijft en wanneer een 30mA differentieelschakelaar verplicht is.","nl",{},"\u002Fblog\u002F30ma-rcd-per-socket.nl",{"title":779,"description":954},"30ma-aardlek-per-stopcontact","blog\u002F30ma-rcd-per-socket.nl",[220,221,962,457,224,963,964,965,966,967,968,231,969],"differentieel","aardlekschakelaar","stopcontact","stroomkring","elektrische keuring","elektrische installatie","België","situatieschema","UCe5OBMy65CIopqtQZ_J6GR7o-o-R77jmXAz2dHF-Gk",1775151659211]