[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"blog-post-fr-abri-jardin-garage-tableau-divisionnaire":3,"blog-alternates-blog-post-fr-abri-jardin-garage-tableau-divisionnaire-garden-house-garage-sub-board":708,"blog-next-steps-blog-post-fr-abri-jardin-garage-tableau-divisionnaire-garden-house-garage-sub-board":3109},{"id":4,"title":5,"articleId":6,"body":7,"category":675,"date":676,"description":677,"extension":678,"image":32,"labels":679,"lastUpdated":676,"locale":684,"meta":685,"navigation":686,"ogImage":687,"path":688,"publishDate":676,"readTime":689,"refreshInterval":690,"seo":691,"seoTitle":692,"slug":693,"stem":694,"tags":695,"__hash__":707},"blog\u002Fblog\u002Fabri-jardin-garage-tableau-divisionnaire.fr.md","Électricité vers l’abri de jardin ou le garage : comment planifier et dessiner câble enterré et tableau divisionnaire selon le RGIE ?","garden-house-garage-sub-board",{"type":8,"value":9,"toc":660},"minimark",[10,26,33,38,43,46,117,130,134,137,206,218,226,230,237,241,244,316,323,327,399,406,410,417,421,424,463,470,474,521,528,535,539,596,608,612,615,619,654],[11,12,13,17,18,25],"p",{},[14,15,16],"strong",{},"Un abri de jardin, un garage indépendant ou un carport est alimenté par un départ propre dans le tableau principal, un câble enterré et, dès que plusieurs circuits sont nécessaires, un tableau divisionnaire."," Le RGIE impose pour le câble enterré une profondeur minimale de 0,60 m ou, si c’est techniquement impossible, une protection mécanique continue (sous-section 5.2.9.2 a). Le tableau divisionnaire est repéré (sous-section 3.1.3.3 a), figure avec son emplacement sur le plan de position (sous-section 3.1.2.3 a) et reçoit sa propre partie dans le schéma unifilaire. Vous pouvez le dessiner gratuitement dans ",[19,20,24],"a",{"href":21,"rel":22},"https:\u002F\u002Fsketch.planelec.be\u002Ffr\u002Fdessiner?start=keuring",[23],"nofollow","PlanElec Sketch"," ; l’exécution, le dimensionnement et le contrôle restent l’affaire de l’électricien et de l’organisme agréé.",[11,27,28],{},[29,30],"img",{"alt":31,"src":32},"Un électricien prépare dans un jardin belge la liaison vers l’abri de jardin et le garage avec un tableau divisionnaire fermé.","\u002Fimages\u002Fblog\u002Feditorial-2026-11-07\u002Fplanelec-garden-house-garage-sub-board-editorial.webp",[11,34,35],{},[14,36,37],{},"État au 7 novembre 2026, Livre 1 du RGIE en version 07. Rédigé par l’équipe PlanElec, qui développe Sketch et Pro.",[39,40,42],"h2",{"id":41},"faut-il-un-tableau-divisionnaire-ou-un-circuit-suffit-il","Faut-il un tableau divisionnaire, ou un circuit suffit-il ?",[11,44,45],{},"Tout dépend de ce qui sera installé dans l’annexe. Le RGIE n’impose pas de tableau divisionnaire ; il fixe la manière d’exécuter et de documenter circuits, canalisations et tableaux.",[47,48,49,65],"table",{},[50,51,52],"thead",{},[53,54,55,59,62],"tr",{},[56,57,58],"th",{},"Usage dans l’annexe",[56,60,61],{},"Solution courante",[56,63,64],{},"Ce qui figure sur le schéma",[66,67,68,80,91,106],"tbody",{},[53,69,70,74,77],{},[71,72,73],"td",{},"Un point lumineux et une prise dans l’abri de jardin",[71,75,76],{},"Un circuit terminal depuis le tableau principal",[71,78,79],{},"Un circuit avec lettre, protection et câble enterré",[53,81,82,85,88],{},[71,83,84],{},"Éclairage, plusieurs prises, établi dans le garage",[71,86,87],{},"Câble d’alimentation vers un tableau divisionnaire avec ses circuits",[71,89,90],{},"Départ au tableau principal, câble d’alimentation, tableau divisionnaire avec circuits",[53,92,93,96,103],{},[71,94,95],{},"Borne de recharge pour voiture électrique sous le carport",[71,97,98,99],{},"Circuit dédié ; détails dans ",[19,100,102],{"href":101},"\u002Ffr\u002Fblog\u002Fborne-recharge-rgie","Borne de recharge et RGIE",[71,104,105],{},"Circuit dédié avec borne",[53,107,108,111,114],{},[71,109,110],{},"Pompe d’étang ou de puits",[71,112,113],{},"Appareil à poste fixe, souvent sur circuit propre",[71,115,116],{},"Circuit avec appareil fixe",[11,118,119,120,124,125,129],{},"Pour les prises, la même limite qu’à l’intérieur s’applique : huit prises simples ou multiples au maximum par circuit terminal (sous-section 5.3.5.2 b, voir ",[19,121,123],{"href":122},"\u002Ffr\u002Fblog\u002Fprises-par-circuit","Combien de prises par circuit ?","). Les appareils qui exigent un circuit dédié sont listés dans ",[19,126,128],{"href":127},"\u002Ffr\u002Fblog\u002Fcircuit-dedie-obligatoire-appareils","Circuit dédié obligatoire",".",[39,131,133],{"id":132},"à-quelle-profondeur-enterrer-le-câble-vers-labri-de-jardin","À quelle profondeur enterrer le câble vers l’abri de jardin ?",[11,135,136],{},"La sous-section 5.2.9.2 a règle les canalisations souterraines :",[47,138,139,149],{},[50,140,141],{},[53,142,143,146],{},[56,144,145],{},"Exigence",[56,147,148],{},"Contenu",[66,150,151,159,167,175,190,198],{},[53,152,153,156],{},[71,154,155],{},"Uniquement des câbles adaptés",[71,157,158],{},"Dans le sol et dans des fourreaux souterrains inaccessibles, uniquement des câbles conformes aux normes applicables (sauf conducteurs de protection indépendants)",[53,160,161,164],{},[71,162,163],{},"Profondeur minimale",[71,165,166],{},"0,60 m sous la surface du sol (terrain, dessus des pavés ou du revêtement), sauf impossibilité technique",[53,168,169,172],{},[71,170,171],{},"Si 0,60 m est impossible",[71,173,174],{},"Protection par un fourreau continu ou un système équivalent en matériau durable et résistant",[53,176,177,180],{},[71,178,179],{},"Protection du câble (une des trois conditions)",[71,181,182,183,186,187,189],{},"écran mis à la terre et armure ou gaine extérieure renforcée ; ",[14,184,185],{},"ou"," gaine résistante plus couverture continue au-dessus du câble contre les outils ; ",[14,188,185],{}," pose sous fourreau",[53,191,192,195],{},[71,193,194],{},"Traversée de mur",[71,196,197],{},"Reboucher soigneusement le trou après la pose (sous-section 5.2.9.2 b)",[53,199,200,203],{},[71,201,202],{},"Câbles de télécommunication",[71,204,205],{},"Au moins 0,50 m de distance des câbles de télécommunication existants (sous-section 5.2.9.2 c.1)",[11,207,208,209,213,214,129],{},"Le choix du câble qui remplit ces conditions et de sa section revient à l’électricien. Sur une longue distance dans le jardin, la chute de tension compte ; pour l’estimer, voyez ",[19,210,212],{"href":211},"\u002Ffr\u002Fblog\u002Fchute-de-tension-section-cable","Chute de tension et section de câble",", et pour l’association section-protection ",[19,215,217],{"href":216},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","Section de câble et disjoncteur",[219,220],"help-figure",{":height":221,":width":222,"alt":223,"caption":224,"src":225},"400","720","Schéma de l’alimentation d’un abri de jardin : le tableau principal comporte un départ avec sa protection. De là, un câble enterré, à 0,60 m minimum ou protégé mécaniquement sur toute sa longueur, rejoint le tableau divisionnaire de l’abri. Le tableau divisionnaire est repéré et alimente les circuits éclairage, prises intérieures et une prise extérieure au degré de protection adapté à la présence d’eau. Les traversées de mur sont rebouchées.","Du tableau principal à l’abri de jardin : départ, câble enterré et tableau divisionnaire avec ses circuits. Protection et section sont fixées par l’électricien.","\u002Fimages\u002Fblog\u002Fdiagrams\u002Fgarden-house-garage-sub-board\u002Foutbuilding-supply.fr.svg",[39,227,229],{"id":228},"le-câble-peut-il-longer-la-façade-ou-la-clôture","Le câble peut-il longer la façade ou la clôture ?",[11,231,232,233,129],{},"À l’air libre et en montage apparent, seuls des câbles peuvent être posés ; font exception les conducteurs de protection et d’équipotentialité indépendants ainsi que les conducteurs actifs mis à la terre indépendants comme le PEN (sous-section 5.2.9.5). Les fixations doivent préserver la canalisation et résister aux influences externes. À l’extérieur des bâtiments, la pose suit les règles de l’art en tenant compte des influences externes (sous-section 5.2.9.14). Un câble posé en façade figure sur le schéma unifilaire avec son mode de pose ; les codes possibles sont expliqués dans ",[19,234,236],{"href":235},"\u002Ffr\u002Fblog\u002Fmodes-de-pose-rgie","Modes de pose selon le RGIE",[39,238,240],{"id":239},"quel-degré-de-protection-pour-les-prises-et-luminaires-extérieurs","Quel degré de protection pour les prises et luminaires extérieurs ?",[11,242,243],{},"Le degré de protection dépend de la présence d’eau à l’endroit d’utilisation, que le RGIE décrit par les codes AD1 à AD8 (sous-section 5.3.2.2, tableau 5.4). Le classement de l’endroit revient à l’électricien.",[47,245,246,259],{},[50,247,248],{},[53,249,250,253,256],{},[56,251,252],{},"Code",[56,254,255],{},"Présence d’eau",[56,257,258],{},"Degré de protection minimal",[66,260,261,272,283,294,305],{},[53,262,263,266,269],{},[71,264,265],{},"AD1",[71,267,268],{},"négligeable",[71,270,271],{},"IPX0",[53,273,274,277,280],{},[71,275,276],{},"AD2",[71,278,279],{},"temporairement humides",[71,281,282],{},"IPX1",[53,284,285,288,291],{},[71,286,287],{},"AD3",[71,289,290],{},"humides",[71,292,293],{},"IPX3",[53,295,296,299,302],{},[71,297,298],{},"AD4",[71,300,301],{},"mouillés",[71,303,304],{},"IPX4",[53,306,307,310,313],{},[71,308,309],{},"AD5",[71,311,312],{},"arrosés",[71,314,315],{},"IPX5",[11,317,318,319,129],{},"Les appareils d’éclairage extérieurs soumis aux influences AD2 à AD4 ne peuvent pas être de classe 0 ou 0I (sous-section 5.3.4.2 h). Le différentiel qui protège les prises de l’abri est expliqué dans ",[19,320,322],{"href":321},"\u002Ffr\u002Fblog\u002F30ma-ddr-par-prise","Différentiel 30 mA par prise ?",[39,324,326],{"id":325},"comment-le-tableau-divisionnaire-figure-t-il-sur-le-schéma-unifilaire-et-le-plan-de-position","Comment le tableau divisionnaire figure-t-il sur le schéma unifilaire et le plan de position ?",[47,328,329,342],{},[50,330,331],{},[53,332,333,336,339],{},[56,334,335],{},"Où",[56,337,338],{},"Ce qui doit y figurer",[56,340,341],{},"Référence",[66,343,344,355,366,377,388],{},[53,345,346,349,352],{},[71,347,348],{},"Schéma unifilaire",[71,350,351],{},"Départ au tableau principal avec protection, câble d’alimentation avec type, section, nombre de conducteurs et mode de pose, tableau divisionnaire avec ses circuits, protections et récepteurs",[71,353,354],{},"sous-section 3.1.2.2 a",[53,356,357,360,363],{},[71,358,359],{},"Repérage des circuits",[71,361,362],{},"Une lettre majuscule par circuit, points numérotés à partir de la protection",[71,364,365],{},"sous-section 3.1.2.1 a",[53,367,368,371,374],{},[71,369,370],{},"Plan de position",[71,372,373],{},"Emplacement du tableau divisionnaire, des prises, points lumineux, interrupteurs et appareils fixes de l’annexe",[71,375,376],{},"sous-section 3.1.2.3 a",[53,378,379,382,385],{},[71,380,381],{},"Sur le tableau",[71,383,384],{},"Repérage individuel et indélébile, et la tension d’alimentation",[71,386,387],{},"sous-section 3.1.3.3 a",[53,389,390,393,396],{},[71,391,392],{},"Aux protections",[71,394,395],{},"Chaque circuit repéré de manière identifiable",[71,397,398],{},"sous-section 3.1.3.1",[11,400,401,402,129],{},"Le tableau divisionnaire de l’abri fait partie de la même installation que la maison tant qu’il dépend du même compteur. Il n’a donc pas de schéma propre, mais une partie dans le schéma de la maison. L’organisation des tableaux principal et divisionnaires est détaillée dans ",[19,403,405],{"href":404},"\u002Ffr\u002Fblog\u002Finstallation-electrique-plusieurs-etages","Installation électrique sur plusieurs étages",[39,407,409],{"id":408},"le-tracé-du-câble-dans-le-jardin-doit-il-figurer-sur-le-plan","Le tracé du câble dans le jardin doit-il figurer sur le plan ?",[11,411,412,413,416],{},"Pour les logements, le RGIE demande sur le plan de position l’emplacement des tableaux, boîtes, prises, points lumineux, interrupteurs et appareils fixes (sous-section 3.1.2.3 a), pas le tracé d’un câble enterré. Ce n’est que pour les installations non domestiques que les propriétaires de canalisations souterraines doivent pouvoir fournir leurs plans ou les données de localisation (sous-section 3.1.2.1 b). Dessiner malgré tout le tracé, avec la profondeur et la position du fourreau, est une bonne habitude : qui posera plus tard une clôture, plantera un arbre ou construira une terrasse saura où ne pas creuser. Dans Sketch, l’outil ",[14,414,415],{},"Texte"," sur le plan de position, à l’endroit où le câble quitte la maison, suffit.",[39,418,420],{"id":419},"sagit-il-dune-extension-importante","S’agit-il d’une extension importante ?",[11,422,423],{},"Est importante une modification ou extension qui a un impact supplémentaire, non encore couvert par un contrôle de conformité, sur la sécurité des personnes ou des biens (section 2.11.2). Un nouveau départ avec câble enterré et tableau propre apporte de nouvelles protections et canalisations ; voyez le classement avec votre électricien.",[47,425,426,439],{},[50,427,428],{},[53,429,430,433,436],{},[56,431,432],{},"Classement",[56,434,435],{},"Plans",[56,437,438],{},"Contrôle",[66,440,441,452],{},[53,442,443,446,449],{},[71,444,445],{},"Importante",[71,447,448],{},"Établir ou mettre à jour schéma unifilaire et plan de position (sous-section 3.1.2.1 a)",[71,450,451],{},"Contrôle de conformité des parties ajoutées et modifiées avant mise en usage (sous-section 6.4.7.3)",[53,453,454,457,460],{},[71,455,456],{},"Non importante",[71,458,459],{},"Brève description datée et signée ; le plan de position montre la modification (sous-section 3.1.2.1 a)",[71,461,462],{},"pas de contrôle de conformité avant mise en usage imposé",[11,464,465,466,129],{},"Les conséquences des transformations sur une installation existante sont expliquées dans ",[19,467,469],{"href":468},"\u002Ffr\u002Fblog\u002Frenovation-rgie-plans-electriques","Rénovation et RGIE",[39,471,473],{"id":472},"comment-dessiner-labri-et-le-tableau-divisionnaire-dans-planelec-sketch","Comment dessiner l’abri et le tableau divisionnaire dans PlanElec Sketch ?",[475,476,477,486,496,503,512],"ol",{},[478,479,480,481,485],"li",{},"Ouvrez ",[19,482,484],{"href":21,"rel":483},[23],"Sketch avec « Dessiner les documents pour le contrôle »"," ou votre dessin existant de la maison. Sans compte, le dessin reste dans le navigateur.",[478,487,488,489,491,492,495],{},"Dans le ",[14,490,348],{},", ajoutez au tableau principal le départ vers l’abri et placez le ",[14,493,494],{},"Tableau divisionnaire"," depuis la bibliothèque sur le câble de ce départ. Raccordez-y les circuits d’éclairage et de prises ; Sketch attribue lettres et numéros.",[478,497,498,499,502],{},"Indiquez sur le câble d’alimentation type, section, pose et longueur dès que l’électricien les a fixés ; Sketch les écrit au câble sur le schéma. D’ici là, une ",[14,500,501],{},"note"," suffit.",[478,504,488,505,507,508,511],{},[14,506,370],{},", créez un étage propre pour l’annexe (",[14,509,510],{},"Ajouter un étage",", par exemple « Abri de jardin ») et glissez tableau, luminaires et prises à leur place.",[478,513,514,517,518,129],{},[14,515,516],{},"Vérifier les documents"," montre ce qui manque, par exemple des appareils sans emplacement sur le plan de position. Puis ",[14,519,520],{},"Créer le PDF",[219,522],{":height":523,":width":524,"alt":525,"caption":526,"src":527},"711","1071","« Plan de position » de PlanElec Sketch avec les onglets d'étage Rez-de-chaussée, Étage et Combles ; dans la pièce, interrupteurs, luminaires et prises avec repère de circuit, à gauche la palette « Depuis le schéma unifilaire » avec une coche sur les circuits placés.","Chaque étage devient une feuille du PDF ; une annexe reçoit son propre étage. La palette montre quels appareils du schéma ont déjà leur place.","\u002Fimages\u002Fblog\u002Fscreens\u002Fsketch\u002Ffr-situation-floors.webp",[11,529,530,531,129],{},"Sketch est gratuit ; sans compte, le PDF porte le logo en filigrane, un compte gratuit le retire. Toutes les limites figurent sur la ",[19,532,534],{"href":533},"\u002Ffr\u002Fpricing","page des tarifs",[39,536,538],{"id":537},"sketch-ou-pro-de-quoi-avez-vous-besoin","Sketch ou Pro : de quoi avez-vous besoin ?",[47,540,541,551],{},[50,542,543],{},[53,544,545,548],{},[56,546,547],{},"Votre situation",[56,549,550],{},"Outil",[66,552,553,564,573,587],{},[53,554,555,558],{},[71,556,557],{},"Propriétaire qui esquisse l’extension avant d’en parler à l’électricien",[71,559,560,563],{},[14,561,562],{},"Sketch",", gratuit",[53,565,566,569],{},[71,567,568],{},"Électricien qui remet schéma unifilaire et plan de position de l’extension",[71,570,571],{},[14,572,562],{},[53,574,575,578],{},[71,576,577],{},"Entreprise qui équipe tableaux principal et divisionnaire dans l’éditeur de tableau et a besoin d’un rapport d’auto-contrôle",[71,579,580,583,584],{},[14,581,582],{},"Pro",", reprise depuis Sketch avec ",[14,585,586],{},"Reprendre dans Pro",[53,588,589,592],{},[71,590,591],{},"Cheminements et longueurs de câbles depuis le plan pour la liste de matériel",[71,593,594],{},[14,595,582],{},[11,597,598,599,603,604,129],{},"Ce que Pro apporte en plus avec la planification du tableau, les cheminements de câbles et l’auto-contrôle est présenté sur la ",[19,600,602],{"href":601},"\u002Ffr\u002Fproduits\u002Fpro","page produit de PlanElec Pro"," ; la création des cheminements y est expliquée dans l’aide ",[19,605,607],{"href":606},"\u002Ffr\u002Fhelp\u002Fcommandes-circuits-et-chemins-de-cables","Commandes, circuits et chemins de câbles",[39,609,611],{"id":610},"limites","Limites",[11,613,614],{},"Cet article reprend les exigences du RGIE pour les câbles enterrés, la pose à l’air libre, le degré de protection et la documentation. Il ne dimensionne aucune canalisation, ne choisit aucune protection et ne classe aucun endroit dans un code AD ; c’est le rôle de l’électricien. Sketch ne vérifie pas les règles du RGIE. La conformité de l’extension est constatée par l’organisme agréé.",[39,616,618],{"id":617},"source-officielle-et-articles-liés","Source officielle et articles liés",[620,621,622,630,636,642,648],"ul",{},[478,623,624,629],{},[19,625,628],{"href":626,"rel":627},"https:\u002F\u002Feconomie.fgov.be\u002Ffr\u002Fpublications\u002Freglement-general-sur-les",[23],"SPF Économie : Règlement général sur les installations électriques, Livre 1"," – section 2.11.2, sous-sections 3.1.2.1 a, 3.1.2.2 a, 3.1.2.3 a, 3.1.3.1, 3.1.3.3 a, 5.2.9.2, 5.2.9.5, 5.2.9.14, 5.3.2.2, 5.3.4.2 h et 6.4.7.3",[478,631,632],{},[19,633,635],{"href":634},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique",[478,637,638],{},[19,639,641],{"href":640},"\u002Ffr\u002Fblog\u002Fcheminements-et-longueurs-de-cables","Cheminements et longueurs de câbles",[478,643,644],{},[19,645,647],{"href":646},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Schéma unifilaire : guide étape par étape",[478,649,650],{},[19,651,653],{"href":652},"\u002Ffr\u002Fblog\u002Fschema-unifilaire-installation-existante","Schéma unifilaire d’une installation existante",[11,655,656],{},[19,657,659],{"href":21,"rel":658},[23],"Dessinez abri et tableau divisionnaire gratuitement dans PlanElec Sketch →",{"title":661,"searchDepth":662,"depth":662,"links":663},"",2,[664,665,666,667,668,669,670,671,672,673,674],{"id":41,"depth":662,"text":42},{"id":132,"depth":662,"text":133},{"id":228,"depth":662,"text":229},{"id":239,"depth":662,"text":240},{"id":325,"depth":662,"text":326},{"id":408,"depth":662,"text":409},{"id":419,"depth":662,"text":420},{"id":472,"depth":662,"text":473},{"id":537,"depth":662,"text":538},{"id":610,"depth":662,"text":611},{"id":617,"depth":662,"text":618},"guide","2026-11-07","Câble enterré à 0,60 m minimum ou protégé mécaniquement, tableau divisionnaire repéré et reporté sur le plan de position, degré de protection selon la présence d’eau : planifiez l’alimentation d’un abri, d’un garage ou d’un carport selon le RGIE et dessinez-la dans PlanElec Sketch.","md",[680,681,682,683],"distribution-board","cables-routing","single-line-diagram","planelec-sketch","fr",{},true,"\u002Fimages\u002Fblog\u002Feditorial-2026-11-07\u002Fshare\u002Fplanelec-garden-house-garage-sub-board-editorial.jpg","\u002Fblog\u002Fabri-jardin-garage-tableau-divisionnaire.fr","9 min",12,{"title":5,"description":677},"Abri de jardin et garage : câble enterré et tableau","abri-jardin-garage-tableau-divisionnaire","blog\u002Fabri-jardin-garage-tableau-divisionnaire.fr",[696,697,698,699,700,701,702,703,704,705,24,706],"électricité abri de jardin","câble enterré abri de jardin","tableau divisionnaire garage","profondeur câble enterré","prise extérieure IP","annexe électricité","schéma unifilaire tableau divisionnaire","RGIE","AREI","plan de position","Belgique","rrlNHRnssoL5lpo9XxYZWpOqq3jOSmD4tdYy6NtefX8",[709,1163,1811,2462],{"id":4,"title":5,"articleId":6,"body":710,"category":675,"date":676,"description":677,"extension":678,"image":32,"labels":1159,"lastUpdated":676,"locale":684,"meta":1160,"navigation":686,"ogImage":687,"path":688,"publishDate":676,"readTime":689,"refreshInterval":690,"seo":1161,"seoTitle":692,"slug":693,"stem":694,"tags":1162,"__hash__":707},{"type":8,"value":711,"toc":1146},[712,719,723,727,729,731,779,785,787,789,841,847,849,851,855,857,859,913,917,919,973,977,979,983,985,987,1017,1021,1023,1052,1054,1058,1060,1106,1112,1114,1116,1118,1141],[11,713,714,17,716,25],{},[14,715,16],{},[19,717,24],{"href":21,"rel":718},[23],[11,720,721],{},[29,722],{"alt":31,"src":32},[11,724,725],{},[14,726,37],{},[39,728,42],{"id":41},[11,730,45],{},[47,732,733,743],{},[50,734,735],{},[53,736,737,739,741],{},[56,738,58],{},[56,740,61],{},[56,742,64],{},[66,744,745,753,761,771],{},[53,746,747,749,751],{},[71,748,73],{},[71,750,76],{},[71,752,79],{},[53,754,755,757,759],{},[71,756,84],{},[71,758,87],{},[71,760,90],{},[53,762,763,765,769],{},[71,764,95],{},[71,766,98,767],{},[19,768,102],{"href":101},[71,770,105],{},[53,772,773,775,777],{},[71,774,110],{},[71,776,113],{},[71,778,116],{},[11,780,119,781,124,783,129],{},[19,782,123],{"href":122},[19,784,128],{"href":127},[39,786,133],{"id":132},[11,788,136],{},[47,790,791,799],{},[50,792,793],{},[53,794,795,797],{},[56,796,145],{},[56,798,148],{},[66,800,801,807,813,819,829,835],{},[53,802,803,805],{},[71,804,155],{},[71,806,158],{},[53,808,809,811],{},[71,810,163],{},[71,812,166],{},[53,814,815,817],{},[71,816,171],{},[71,818,174],{},[53,820,821,823],{},[71,822,179],{},[71,824,182,825,186,827,189],{},[14,826,185],{},[14,828,185],{},[53,830,831,833],{},[71,832,194],{},[71,834,197],{},[53,836,837,839],{},[71,838,202],{},[71,840,205],{},[11,842,208,843,213,845,129],{},[19,844,212],{"href":211},[19,846,217],{"href":216},[219,848],{":height":221,":width":222,"alt":223,"caption":224,"src":225},[39,850,229],{"id":228},[11,852,232,853,129],{},[19,854,236],{"href":235},[39,856,240],{"id":239},[11,858,243],{},[47,860,861,871],{},[50,862,863],{},[53,864,865,867,869],{},[56,866,252],{},[56,868,255],{},[56,870,258],{},[66,872,873,881,889,897,905],{},[53,874,875,877,879],{},[71,876,265],{},[71,878,268],{},[71,880,271],{},[53,882,883,885,887],{},[71,884,276],{},[71,886,279],{},[71,888,282],{},[53,890,891,893,895],{},[71,892,287],{},[71,894,290],{},[71,896,293],{},[53,898,899,901,903],{},[71,900,298],{},[71,902,301],{},[71,904,304],{},[53,906,907,909,911],{},[71,908,309],{},[71,910,312],{},[71,912,315],{},[11,914,318,915,129],{},[19,916,322],{"href":321},[39,918,326],{"id":325},[47,920,921,931],{},[50,922,923],{},[53,924,925,927,929],{},[56,926,335],{},[56,928,338],{},[56,930,341],{},[66,932,933,941,949,957,965],{},[53,934,935,937,939],{},[71,936,348],{},[71,938,351],{},[71,940,354],{},[53,942,943,945,947],{},[71,944,359],{},[71,946,362],{},[71,948,365],{},[53,950,951,953,955],{},[71,952,370],{},[71,954,373],{},[71,956,376],{},[53,958,959,961,963],{},[71,960,381],{},[71,962,384],{},[71,964,387],{},[53,966,967,969,971],{},[71,968,392],{},[71,970,395],{},[71,972,398],{},[11,974,401,975,129],{},[19,976,405],{"href":404},[39,978,409],{"id":408},[11,980,412,981,416],{},[14,982,415],{},[39,984,420],{"id":419},[11,986,423],{},[47,988,989,999],{},[50,990,991],{},[53,992,993,995,997],{},[56,994,432],{},[56,996,435],{},[56,998,438],{},[66,1000,1001,1009],{},[53,1002,1003,1005,1007],{},[71,1004,445],{},[71,1006,448],{},[71,1008,451],{},[53,1010,1011,1013,1015],{},[71,1012,456],{},[71,1014,459],{},[71,1016,462],{},[11,1018,465,1019,129],{},[19,1020,469],{"href":468},[39,1022,473],{"id":472},[475,1024,1025,1030,1036,1040,1046],{},[478,1026,480,1027,485],{},[19,1028,484],{"href":21,"rel":1029},[23],[478,1031,488,1032,491,1034,495],{},[14,1033,348],{},[14,1035,494],{},[478,1037,498,1038,502],{},[14,1039,501],{},[478,1041,488,1042,507,1044,511],{},[14,1043,370],{},[14,1045,510],{},[478,1047,1048,517,1050,129],{},[14,1049,516],{},[14,1051,520],{},[219,1053],{":height":523,":width":524,"alt":525,"caption":526,"src":527},[11,1055,530,1056,129],{},[19,1057,534],{"href":533},[39,1059,538],{"id":537},[47,1061,1062,1070],{},[50,1063,1064],{},[53,1065,1066,1068],{},[56,1067,547],{},[56,1069,550],{},[66,1071,1072,1080,1088,1098],{},[53,1073,1074,1076],{},[71,1075,557],{},[71,1077,1078,563],{},[14,1079,562],{},[53,1081,1082,1084],{},[71,1083,568],{},[71,1085,1086],{},[14,1087,562],{},[53,1089,1090,1092],{},[71,1091,577],{},[71,1093,1094,583,1096],{},[14,1095,582],{},[14,1097,586],{},[53,1099,1100,1102],{},[71,1101,591],{},[71,1103,1104],{},[14,1105,582],{},[11,1107,598,1108,603,1110,129],{},[19,1109,602],{"href":601},[19,1111,607],{"href":606},[39,1113,611],{"id":610},[11,1115,614],{},[39,1117,618],{"id":617},[620,1119,1120,1125,1129,1133,1137],{},[478,1121,1122,629],{},[19,1123,628],{"href":626,"rel":1124},[23],[478,1126,1127],{},[19,1128,635],{"href":634},[478,1130,1131],{},[19,1132,641],{"href":640},[478,1134,1135],{},[19,1136,647],{"href":646},[478,1138,1139],{},[19,1140,653],{"href":652},[11,1142,1143],{},[19,1144,659],{"href":21,"rel":1145},[23],{"title":661,"searchDepth":662,"depth":662,"links":1147},[1148,1149,1150,1151,1152,1153,1154,1155,1156,1157,1158],{"id":41,"depth":662,"text":42},{"id":132,"depth":662,"text":133},{"id":228,"depth":662,"text":229},{"id":239,"depth":662,"text":240},{"id":325,"depth":662,"text":326},{"id":408,"depth":662,"text":409},{"id":419,"depth":662,"text":420},{"id":472,"depth":662,"text":473},{"id":537,"depth":662,"text":538},{"id":610,"depth":662,"text":611},{"id":617,"depth":662,"text":618},[680,681,682,683],{},{"title":5,"description":677},[696,697,698,699,700,701,702,703,704,705,24,706],{"id":1164,"title":1165,"articleId":6,"body":1166,"category":675,"date":676,"description":1792,"extension":678,"image":32,"labels":1793,"lastUpdated":676,"locale":1794,"meta":1795,"navigation":686,"ogImage":687,"path":1796,"publishDate":676,"readTime":689,"refreshInterval":690,"seo":1797,"seoTitle":1798,"slug":6,"stem":1799,"tags":1800,"__hash__":1810},"blog\u002Fblog\u002Fgarden-house-garage-sub-board.en.md","Power to the garden shed or garage: how do I plan and draw the buried cable and sub-board under the AREI\u002FRGIE?",{"type":8,"value":1167,"toc":1779},[1168,1179,1184,1189,1193,1196,1261,1273,1277,1280,1349,1361,1366,1370,1377,1381,1384,1445,1452,1456,1528,1535,1539,1546,1550,1553,1591,1598,1602,1646,1651,1658,1662,1717,1729,1733,1736,1740,1773],[11,1169,1170,1173,1174,1178],{},[14,1171,1172],{},"A garden shed, a detached garage or a carport gets its power from its own outgoing circuit in the main distribution board, a buried cable and, as soon as several circuits are needed, a sub-board."," The AREI\u002FRGIE requires a minimum depth of 0.60 m for the buried cable or, where that is technically impossible, continuous mechanical protection (sub-section 5.2.9.2 a). The sub-board is labelled (sub-section 3.1.3.3 a), shown with its location on the situation plan (sub-section 3.1.2.3 a) and given its own section in the single-line diagram. You can draw it for free in ",[19,1175,24],{"href":1176,"rel":1177},"https:\u002F\u002Fsketch.planelec.be\u002Fen\u002Fdraw?start=keuring",[23],"; installation, sizing and inspection remain the job of the electrician and the accredited inspection body.",[11,1180,1181],{},[29,1182],{"alt":1183,"src":32},"An electrician plans a route to a garden house and garage with a closed sub-board in a Belgian garden.",[11,1185,1186],{},[14,1187,1188],{},"Status 7 November 2026, AREI\u002FRGIE Book 1 version 07. The AREI (Dutch) and RGIE (French) are the Belgian general regulations on electrical installations. Written by the PlanElec team, which builds Sketch and Pro.",[39,1190,1192],{"id":1191},"do-i-need-a-sub-board-or-is-one-circuit-enough","Do I need a sub-board, or is one circuit enough?",[11,1194,1195],{},"That depends on what goes into the outbuilding. The AREI\u002FRGIE does not require a sub-board; it sets how circuits, wiring and boards are installed and documented.",[47,1197,1198,1211],{},[50,1199,1200],{},[53,1201,1202,1205,1208],{},[56,1203,1204],{},"Use in the outbuilding",[56,1206,1207],{},"Typical solution",[56,1209,1210],{},"What appears on the diagram",[66,1212,1213,1224,1235,1250],{},[53,1214,1215,1218,1221],{},[71,1216,1217],{},"One light and one socket in the garden shed",[71,1219,1220],{},"One final circuit from the main board",[71,1222,1223],{},"One circuit with letter, protective device and buried cable",[53,1225,1226,1229,1232],{},[71,1227,1228],{},"Lighting, several sockets, a workbench in the garage",[71,1230,1231],{},"Feeder cable to a sub-board with its own circuits",[71,1233,1234],{},"Outgoing circuit in the main board, feeder, sub-board with circuits",[53,1236,1237,1240,1247],{},[71,1238,1239],{},"EV charging point under the carport",[71,1241,1242,1243],{},"Dedicated circuit; details in ",[19,1244,1246],{"href":1245},"\u002Fen\u002Fblog\u002Fev-charger-arei","EV charger under the AREI",[71,1248,1249],{},"Dedicated circuit with charging point",[53,1251,1252,1255,1258],{},[71,1253,1254],{},"Pond or well pump",[71,1256,1257],{},"Appliance in a fixed location, often on its own circuit",[71,1259,1260],{},"Circuit with fixed appliance",[11,1262,1263,1264,1268,1269,129],{},"For sockets, the same limit applies as in the house: at most eight single or multiple socket outlets per final circuit (sub-section 5.3.5.2 b, see ",[19,1265,1267],{"href":1266},"\u002Fen\u002Fblog\u002Fsockets-per-circuit","How many sockets per circuit?","). Which appliances need a dedicated circuit is listed in ",[19,1270,1272],{"href":1271},"\u002Fen\u002Fblog\u002Fdedicated-circuits-appliances","Dedicated circuits for appliances",[39,1274,1276],{"id":1275},"how-deep-must-the-cable-to-the-garden-shed-be-buried","How deep must the cable to the garden shed be buried?",[11,1278,1279],{},"Sub-section 5.2.9.2 a covers underground wiring:",[47,1281,1282,1292],{},[50,1283,1284],{},[53,1285,1286,1289],{},[56,1287,1288],{},"Requirement",[56,1290,1291],{},"Content",[66,1293,1294,1302,1310,1318,1333,1341],{},[53,1295,1296,1299],{},[71,1297,1298],{},"Suitable cables only",[71,1300,1301],{},"In the ground and in inaccessible underground ducts, only cables complying with the applicable standards (except independent protective conductors)",[53,1303,1304,1307],{},[71,1305,1306],{},"Minimum depth",[71,1308,1309],{},"0.60 m below the surface (ground level, top of paving or road surface), unless technically impossible",[53,1311,1312,1315],{},[71,1313,1314],{},"If 0.60 m is not possible",[71,1316,1317],{},"Protection by a continuous duct or an equivalent system of durable, resistant material",[53,1319,1320,1323],{},[71,1321,1322],{},"Cable protection (one of three conditions)",[71,1324,1325,1326,1329,1330,1332],{},"earthed screen and armour or reinforced outer sheath; ",[14,1327,1328],{},"or"," resistant outer sheath plus a continuous cover above the cable against tools; ",[14,1331,1328],{}," laying in a duct",[53,1334,1335,1338],{},[71,1336,1337],{},"Wall penetration",[71,1339,1340],{},"Carefully seal the hole after laying (sub-section 5.2.9.2 b)",[53,1342,1343,1346],{},[71,1344,1345],{},"Telecommunication cables",[71,1347,1348],{},"At least 0.50 m distance from existing telecommunication cables (sub-section 5.2.9.2 c.1)",[11,1350,1351,1352,1356,1357,129],{},"Which cable meets these conditions and which cross-section is needed is decided by the electrician. Long runs through the garden make voltage drop relevant; how to estimate it is shown in ",[19,1353,1355],{"href":1354},"\u002Fen\u002Fblog\u002Fvoltage-drop-cable-sizing","Calculating voltage drop",", and matching cross-section to protection in ",[19,1358,1360],{"href":1359},"\u002Fen\u002Fblog\u002Fcable-cross-section-breaker","Cable cross-section and circuit breaker",[219,1362],{":height":221,":width":222,"alt":1363,"caption":1364,"src":1365},"Diagram of the supply to a garden shed: the main distribution board has an outgoing circuit with its protective device. From there a buried cable, at least 0.60 m deep or mechanically protected along its length, runs to the sub-board in the shed. The sub-board is labelled and feeds the circuits lighting, indoor sockets and an outdoor socket with a degree of protection matching the presence of water. Wall penetrations are sealed.","From the main board to the garden shed: outgoing circuit, buried cable and sub-board with its own circuits. Protective device and cross-section are set by the electrician.","\u002Fimages\u002Fblog\u002Fdiagrams\u002Fgarden-house-garage-sub-board\u002Foutbuilding-supply.en.svg",[39,1367,1369],{"id":1368},"may-the-cable-run-along-the-façade-or-the-fence","May the cable run along the façade or the fence?",[11,1371,1372,1373,129],{},"In the open air and surface-mounted, only cables may be installed; independent protective and bonding conductors and independent earthed live conductors such as PEN are exempt (sub-section 5.2.9.5). Fixings must keep the wiring undamaged and withstand the external influences. Outside buildings, installation follows good practice, taking the external influences into account (sub-section 5.2.9.14). A cable on the façade appears on the single-line diagram with its installation method; the available codes are explained in ",[19,1374,1376],{"href":1375},"\u002Fen\u002Fblog\u002Finstallation-methods-arei","Installation methods under the AREI",[39,1378,1380],{"id":1379},"what-degree-of-protection-do-outdoor-sockets-and-lights-need","What degree of protection do outdoor sockets and lights need?",[11,1382,1383],{},"The degree of protection depends on the presence of water where the equipment is used, which the AREI\u002FRGIE describes with codes AD1 to AD8 (sub-section 5.3.2.2, table 5.4). Classifying the location is the electrician's job.",[47,1385,1386,1398],{},[50,1387,1388],{},[53,1389,1390,1392,1395],{},[56,1391,252],{},[56,1393,1394],{},"Presence of water",[56,1396,1397],{},"Minimum degree of protection",[66,1399,1400,1409,1418,1427,1436],{},[53,1401,1402,1404,1407],{},[71,1403,265],{},[71,1405,1406],{},"negligible",[71,1408,271],{},[53,1410,1411,1413,1416],{},[71,1412,276],{},[71,1414,1415],{},"dripping water",[71,1417,282],{},[53,1419,1420,1422,1425],{},[71,1421,287],{},[71,1423,1424],{},"spraying water",[71,1426,293],{},[53,1428,1429,1431,1434],{},[71,1430,298],{},[71,1432,1433],{},"splashing water",[71,1435,304],{},[53,1437,1438,1440,1443],{},[71,1439,309],{},[71,1441,1442],{},"water jets",[71,1444,315],{},[11,1446,1447,1448,129],{},"Outdoor lighting fittings exposed to AD2 to AD4 may not be class 0 or 0I (sub-section 5.3.4.2 h). Which RCD protects the sockets in the shed is explained in ",[19,1449,1451],{"href":1450},"\u002Fen\u002Fblog\u002F30ma-rcd-per-socket","A 30 mA RCD for every socket?",[39,1453,1455],{"id":1454},"how-does-the-sub-board-appear-on-the-single-line-diagram-and-the-situation-plan","How does the sub-board appear on the single-line diagram and the situation plan?",[47,1457,1458,1471],{},[50,1459,1460],{},[53,1461,1462,1465,1468],{},[56,1463,1464],{},"Where",[56,1466,1467],{},"What belongs there",[56,1469,1470],{},"Reference",[66,1472,1473,1484,1495,1506,1517],{},[53,1474,1475,1478,1481],{},[71,1476,1477],{},"Single-line diagram",[71,1479,1480],{},"Outgoing circuit in the main board with protective device, feeder cable with type, cross-section, number of conductors and installation method, sub-board with its circuits, protective devices and loads",[71,1482,1483],{},"sub-section 3.1.2.2 a",[53,1485,1486,1489,1492],{},[71,1487,1488],{},"Circuit referencing",[71,1490,1491],{},"One capital letter per circuit, points numbered from the protective device",[71,1493,1494],{},"sub-section 3.1.2.1 a",[53,1496,1497,1500,1503],{},[71,1498,1499],{},"Situation plan",[71,1501,1502],{},"Location of the sub-board, sockets, light points, switches and fixed appliances in the outbuilding",[71,1504,1505],{},"sub-section 3.1.2.3 a",[53,1507,1508,1511,1514],{},[71,1509,1510],{},"On the board itself",[71,1512,1513],{},"Individual, indelible labelling and the supply voltage",[71,1515,1516],{},"sub-section 3.1.3.3 a",[53,1518,1519,1522,1525],{},[71,1520,1521],{},"At the protective devices",[71,1523,1524],{},"Every circuit identifiably labelled",[71,1526,1527],{},"sub-section 3.1.3.1",[11,1529,1530,1531,129],{},"The sub-board in the garden shed belongs to the same installation as the house as long as it hangs on the same meter. It therefore gets no diagram of its own, but a section in the diagram of the house. How main and sub-boards are structured is explained in ",[19,1532,1534],{"href":1533},"\u002Fen\u002Fblog\u002Fmulti-storey-electrical-planning","Electrical planning across several floors",[39,1536,1538],{"id":1537},"does-the-cable-route-through-the-garden-belong-on-the-plan","Does the cable route through the garden belong on the plan?",[11,1540,1541,1542,1545],{},"For homes, the AREI\u002FRGIE requires the situation plan to show the location of boards, boxes, sockets, light points, switches and fixed appliances (sub-section 3.1.2.3 a), not the route of a buried cable. Only for non-domestic installations must owners of underground wiring be able to provide its plans or the data needed to locate it (sub-section 3.1.2.1 b). Drawing the route anyway, with the depth and position of the duct, is a good habit: whoever later puts up a fence, plants a tree or builds a terrace knows where not to dig. In Sketch, the ",[14,1543,1544],{},"Text"," tool on the situation plan, placed where the cable leaves the house, is enough.",[39,1547,1549],{"id":1548},"is-this-a-substantial-extension","Is this a substantial extension?",[11,1551,1552],{},"An alteration or extension is substantial if it has an additional effect on the safety of persons or property that no conformity inspection has covered yet (section 2.11.2). A new outgoing circuit with a buried cable and its own board brings new protective devices and wiring; agree the classification with your electrician.",[47,1554,1555,1567],{},[50,1556,1557],{},[53,1558,1559,1562,1564],{},[56,1560,1561],{},"Classification",[56,1563,435],{},[56,1565,1566],{},"Inspection",[66,1568,1569,1580],{},[53,1570,1571,1574,1577],{},[71,1572,1573],{},"Substantial",[71,1575,1576],{},"Draw or update the single-line diagram and situation plan (sub-section 3.1.2.1 a)",[71,1578,1579],{},"Conformity inspection of the added and altered parts before use (sub-section 6.4.7.3)",[53,1581,1582,1585,1588],{},[71,1583,1584],{},"Not substantial",[71,1586,1587],{},"Short, dated and signed description; the situation plan shows the change (sub-section 3.1.2.1 a)",[71,1589,1590],{},"no conformity inspection before use required",[11,1592,1593,1594,129],{},"The consequences of alterations to an existing installation are covered in ",[19,1595,1597],{"href":1596},"\u002Fen\u002Fblog\u002Frenovation-electrical-plans","Renovation and electrical plans",[39,1599,1601],{"id":1600},"how-do-i-draw-the-shed-and-sub-board-in-planelec-sketch","How do I draw the shed and sub-board in PlanElec Sketch?",[475,1603,1604,1612,1622,1628,1637],{},[478,1605,1606,1607,1611],{},"Open ",[19,1608,1610],{"href":1176,"rel":1609},[23],"Sketch with ‘Draw the documents for the inspection’"," or your existing drawing of the house. Without an account the drawing stays in the browser.",[478,1613,1614,1615,1617,1618,1621],{},"In the ",[14,1616,1477],{},", add the outgoing circuit to the shed at the main board and place the ",[14,1619,1620],{},"Sub-board"," from the library onto the cable of that circuit. Connect the lighting and socket circuits to the sub-board; Sketch assigns letters and numbers.",[478,1623,1624,1625,1627],{},"Enter type, cross-section, installation and length on the feeder cable once the electrician has set them; Sketch writes them next to the cable on the diagram. Until then, a ",[14,1626,501],{}," helps.",[478,1629,1614,1630,1632,1633,1636],{},[14,1631,1499],{},", create a separate floor for the outbuilding (",[14,1634,1635],{},"Add floor",", for example ‘Garden shed’) and drag the sub-board, lights and sockets to their place.",[478,1638,1639,1642,1643,129],{},[14,1640,1641],{},"Check documents"," shows what is still missing, such as devices without a place on the situation plan. Then ",[14,1644,1645],{},"Create PDF",[219,1647],{":height":523,":width":524,"alt":1648,"caption":1649,"src":1650},"‘Situation plan’ in PlanElec Sketch with the floor tabs Ground floor, First floor and Attic; switches, lights and sockets with circuit references stand in the room, on the left the palette ‘From the single-line diagram’ with ticks on the placed circuits.","Each floor becomes its own sheet in the PDF; an outbuilding gets its own floor. The palette shows which devices from the diagram already have a place.","\u002Fimages\u002Fblog\u002Fscreens\u002Fsketch\u002Fen-situation-floors.webp",[11,1652,1653,1654,129],{},"Sketch is free; without an account the PDF carries a logo watermark, and a free account removes it. All limits are on the ",[19,1655,1657],{"href":1656},"\u002Fen\u002Fpricing","pricing page",[39,1659,1661],{"id":1660},"sketch-or-pro-what-do-you-need","Sketch or Pro: what do you need?",[47,1663,1664,1674],{},[50,1665,1666],{},[53,1667,1668,1671],{},[56,1669,1670],{},"Your situation",[56,1672,1673],{},"Tool",[66,1675,1676,1686,1695,1708],{},[53,1677,1678,1681],{},[71,1679,1680],{},"Owner sketching the extension before talking to the electrician",[71,1682,1683,1685],{},[14,1684,562],{},", free",[53,1687,1688,1691],{},[71,1689,1690],{},"Electrician delivering the single-line diagram and situation plan of the extension",[71,1692,1693],{},[14,1694,562],{},[53,1696,1697,1700],{},[71,1698,1699],{},"Contractor laying out main and sub-board in the board editor and needing a self-check report",[71,1701,1702,1704,1705],{},[14,1703,582],{},", taken over from Sketch with ",[14,1706,1707],{},"Take it to Pro",[53,1709,1710,1713],{},[71,1711,1712],{},"Cable routes and lengths from the floor plan for the bill of materials",[71,1714,1715],{},[14,1716,582],{},[11,1718,1719,1720,1724,1725,129],{},"What Pro adds with board planning, cable routes and the self-check is shown on the ",[19,1721,1723],{"href":1722},"\u002Fen\u002Fproducts\u002Fpro","PlanElec Pro product page","; how cable routes are created there is explained in the help guide ",[19,1726,1728],{"href":1727},"\u002Fen\u002Fhelp\u002Fswitch-chains-circuits-and-cable-routes","Switch chains, circuits and cable routes",[39,1730,1732],{"id":1731},"limits","Limits",[11,1734,1735],{},"This article sets out the AREI\u002FRGIE requirements for buried cables, open-air installation, degree of protection and documentation. It does not size any cable, choose any protective device or assign any location to an AD code; that is the electrician's job. Sketch checks no AREI\u002FRGIE rules. Whether the extension complies is established by the accredited inspection body.",[39,1737,1739],{"id":1738},"official-source-and-further-reading","Official source and further reading",[620,1741,1742,1749,1755,1761,1767],{},[478,1743,1744,1748],{},[19,1745,1747],{"href":626,"rel":1746},[23],"FPS Economy: General regulations on electrical installations (RGIE), Book 1, French version"," – section 2.11.2, sub-sections 3.1.2.1 a, 3.1.2.2 a, 3.1.2.3 a, 3.1.3.1, 3.1.3.3 a, 5.2.9.2, 5.2.9.5, 5.2.9.14, 5.3.2.2, 5.3.4.2 h and 6.4.7.3",[478,1750,1751],{},[19,1752,1754],{"href":1753},"\u002Fen\u002Fblog\u002Fdistribution-board-planning-guide","Distribution board planning guide",[478,1756,1757],{},[19,1758,1760],{"href":1759},"\u002Fen\u002Fblog\u002Fcable-routes-and-lengths","Cable routes and lengths",[478,1762,1763],{},[19,1764,1766],{"href":1765},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","Creating a single-line diagram step by step",[478,1768,1769],{},[19,1770,1772],{"href":1771},"\u002Fen\u002Fblog\u002Fsingle-line-diagram-existing-installation","Single-line diagram of an existing installation",[11,1774,1775],{},[19,1776,1778],{"href":1176,"rel":1777},[23],"Draw the shed and sub-board for free in PlanElec Sketch →",{"title":661,"searchDepth":662,"depth":662,"links":1780},[1781,1782,1783,1784,1785,1786,1787,1788,1789,1790,1791],{"id":1191,"depth":662,"text":1192},{"id":1275,"depth":662,"text":1276},{"id":1368,"depth":662,"text":1369},{"id":1379,"depth":662,"text":1380},{"id":1454,"depth":662,"text":1455},{"id":1537,"depth":662,"text":1538},{"id":1548,"depth":662,"text":1549},{"id":1600,"depth":662,"text":1601},{"id":1660,"depth":662,"text":1661},{"id":1731,"depth":662,"text":1732},{"id":1738,"depth":662,"text":1739},"Buried cable at least 0.60 m deep or mechanically protected, sub-board labelled and shown on the situation plan, degree of protection according to water: how to plan the supply of a garden shed, garage or carport under the Belgian AREI\u002FRGIE and draw it in PlanElec Sketch.",[680,681,682,683],"en",{},"\u002Fblog\u002Fgarden-house-garage-sub-board.en",{"title":1165,"description":1792},"Garden shed and garage: buried cable and sub-board","blog\u002Fgarden-house-garage-sub-board.en",[1801,1802,1803,1804,1805,1806,1807,704,703,1808,24,1809],"power to garden shed","buried cable garden shed","garage sub-board","buried cable depth Belgium","outdoor socket IP rating","outbuilding electrics","single-line diagram sub-board","eendraadschema","Belgium","LPv35F6SqdV_QNQdtrWym3H-gZGkBTOqqsJKja1eHMM",{"id":1812,"title":1813,"articleId":6,"body":1814,"category":675,"date":676,"description":2442,"extension":678,"image":32,"labels":2443,"lastUpdated":676,"locale":2444,"meta":2445,"navigation":686,"ogImage":687,"path":2446,"publishDate":676,"readTime":689,"refreshInterval":690,"seo":2447,"seoTitle":2448,"slug":2449,"stem":2450,"tags":2451,"__hash__":2461},"blog\u002Fblog\u002Fgartenhaus-garage-unterverteiler-eindrahtschema.de.md","Strom ins Gartenhaus oder in die Garage: Wie plane und zeichne ich Erdkabel und Unterverteiler nach AREI?",{"type":8,"value":1815,"toc":2429},[1816,1827,1832,1837,1841,1844,1909,1921,1925,1928,1997,2009,2014,2018,2025,2029,2032,2093,2100,2104,2176,2183,2187,2193,2197,2200,2239,2246,2250,2295,2300,2307,2311,2366,2378,2382,2385,2389,2423],[11,1817,1818,1821,1822,1826],{},[14,1819,1820],{},"Ein Gartenhaus, eine freistehende Garage oder ein Carport bekommt Strom über einen eigenen Abgang im Hauptverteiler, ein Erdkabel und, sobald dort mehrere Stromkreise nötig sind, einen Unterverteiler."," Das AREI verlangt für das Erdkabel eine Mindesttiefe von 0,60 m oder, wo das technisch nicht geht, einen durchgehenden mechanischen Schutz (Unterabschnitt 5.2.9.2 a). Der Unterverteiler wird gekennzeichnet (Unterabschnitt 3.1.3.3 a), steht mit seiner Lage im Positionsplan (Unterabschnitt 3.1.2.3 a) und bekommt im Eindrahtschema einen eigenen Abschnitt. Zeichnen kannst du das gratis in ",[19,1823,24],{"href":1824,"rel":1825},"https:\u002F\u002Fsketch.planelec.be\u002Fde\u002Fzeichnen?start=keuring",[23],"; Ausführung, Bemessung und Prüfung bleiben Sache der Elektrofachkraft und der Kontrollstelle.",[11,1828,1829],{},[29,1830],{"alt":1831,"src":32},"Elektriker plant im Garten eines belgischen Wohnhauses die Verbindung zu Gartenhaus und Garage mit geschlossenem Unterverteiler.",[11,1833,1834],{},[14,1835,1836],{},"Stand 7. November 2026, AREI Buch 1 in der Fassung 07. Geschrieben vom PlanElec-Team, das Sketch und Pro baut.",[39,1838,1840],{"id":1839},"brauche-ich-einen-unterverteiler-oder-reicht-ein-stromkreis","Brauche ich einen Unterverteiler, oder reicht ein Stromkreis?",[11,1842,1843],{},"Das hängt davon ab, was im Nebengebäude hängt. Das AREI schreibt keinen Unterverteiler vor; es schreibt vor, wie Stromkreise, Leitungen und Verteiler auszuführen und zu dokumentieren sind.",[47,1845,1846,1859],{},[50,1847,1848],{},[53,1849,1850,1853,1856],{},[56,1851,1852],{},"Nutzung im Nebengebäude",[56,1854,1855],{},"Typische Lösung",[56,1857,1858],{},"Was im Schema erscheint",[66,1860,1861,1872,1883,1898],{},[53,1862,1863,1866,1869],{},[71,1864,1865],{},"Eine Leuchte und eine Steckdose im Gartenhaus",[71,1867,1868],{},"Ein Endstromkreis aus dem Hauptverteiler",[71,1870,1871],{},"Ein Stromkreis mit Buchstabe, Schutzorgan und Erdkabel",[53,1873,1874,1877,1880],{},[71,1875,1876],{},"Licht, mehrere Steckdosen, Werkbank in der Garage",[71,1878,1879],{},"Zuleitung zu einem Unterverteiler mit eigenen Stromkreisen",[71,1881,1882],{},"Abgang im Hauptverteiler, Zuleitung, Unterverteiler mit Stromkreisen",[53,1884,1885,1888,1895],{},[71,1886,1887],{},"Ladepunkt für ein E-Auto im Carport",[71,1889,1890,1891],{},"Eigener Stromkreis; Details in ",[19,1892,1894],{"href":1893},"\u002Fde\u002Fblog\u002Fwallbox-arei","Wallbox nach AREI",[71,1896,1897],{},"Eigener Stromkreis mit Ladepunkt",[53,1899,1900,1903,1906],{},[71,1901,1902],{},"Pumpe für Teich oder Brunnen",[71,1904,1905],{},"Gerät mit festem Standplatz, oft eigener Stromkreis",[71,1907,1908],{},"Stromkreis mit ortsfestem Gerät",[11,1910,1911,1912,1916,1917,129],{},"Für die Steckdosen gilt dieselbe Grenze wie im Haus: höchstens acht Einzel- oder Mehrfachsteckdosen je Endstromkreis (Unterabschnitt 5.3.5.2 b, siehe ",[19,1913,1915],{"href":1914},"\u002Fde\u002Fblog\u002Fsteckdosen-pro-stromkreis","Wie viele Steckdosen pro Stromkreis?","). Welche Geräte einen eigenen Stromkreis brauchen, steht in ",[19,1918,1920],{"href":1919},"\u002Fde\u002Fblog\u002Feigener-stromkreis-pflicht-geraete","Eigener Stromkreis Pflicht",[39,1922,1924],{"id":1923},"wie-tief-muss-das-kabel-zum-gartenhaus-liegen","Wie tief muss das Kabel zum Gartenhaus liegen?",[11,1926,1927],{},"Unterabschnitt 5.2.9.2 a regelt unterirdische Leitungen:",[47,1929,1930,1940],{},[50,1931,1932],{},[53,1933,1934,1937],{},[56,1935,1936],{},"Anforderung",[56,1938,1939],{},"Inhalt",[66,1941,1942,1950,1958,1966,1981,1989],{},[53,1943,1944,1947],{},[71,1945,1946],{},"Nur geeignete Kabel",[71,1948,1949],{},"In der Erde und in unzugänglichen unterirdischen Kabelrohren nur Kabel nach den dafür geltenden Normen (Ausnahme: unabhängige Schutzleiter)",[53,1951,1952,1955],{},[71,1953,1954],{},"Mindesttiefe",[71,1956,1957],{},"0,60 m ab Bodenoberfläche (Erde, Oberseite von Pflaster oder Straßenbelag), sofern technisch nicht unmöglich",[53,1959,1960,1963],{},[71,1961,1962],{},"Wenn 0,60 m nicht möglich ist",[71,1964,1965],{},"Schutz durch ein durchgehendes Kabelrohr oder ein gleichwertiges System aus dauerhaftem, widerstandsfähigem Material",[53,1967,1968,1971],{},[71,1969,1970],{},"Schutz des Kabels (eine der drei Bedingungen)",[71,1972,1973,1974,1977,1978,1980],{},"geerdeter Schirm und Bewehrung oder verstärkter Außenmantel; ",[14,1975,1976],{},"oder"," widerstandsfähiger Außenmantel plus durchgehende Abdeckung über dem Kabel gegen Werkzeuge; ",[14,1979,1976],{}," Verlegung in einem Kabelrohr",[53,1982,1983,1986],{},[71,1984,1985],{},"Mauerdurchführung",[71,1987,1988],{},"Loch nach der Verlegung sorgfältig abdichten (Unterabschnitt 5.2.9.2 b)",[53,1990,1991,1994],{},[71,1992,1993],{},"Telekommunikationskabel",[71,1995,1996],{},"Mindestens 0,50 m Abstand zu vorhandenen Telekommunikationskabeln (Unterabschnitt 5.2.9.2 c.1)",[11,1998,1999,2000,2004,2005,129],{},"Welches Kabel die Bedingungen erfüllt und welcher Querschnitt nötig ist, legt die Elektrofachkraft fest. Lange Wege durch den Garten machen den Spannungsfall zum Thema; wie du ihn abschätzt, zeigt ",[19,2001,2003],{"href":2002},"\u002Fde\u002Fblog\u002Fspannungsfall-berechnen-kabelquerschnitt","Spannungsfall berechnen",", die Zuordnung von Querschnitt und Schutzorgan ",[19,2006,2008],{"href":2007},"\u002Fde\u002Fblog\u002Fkabelquerschnitt-sicherungsautomat","Kabelquerschnitt für Sicherungsautomat",[219,2010],{":height":221,":width":222,"alt":2011,"caption":2012,"src":2013},"Schema der Versorgung eines Gartenhauses: Im Hauptverteiler sitzt ein Abgang mit Schutzorgan. Von dort führt ein Erdkabel, mindestens 0,60 m tief oder durchgehend mechanisch geschützt, zum Unterverteiler im Gartenhaus. Der Unterverteiler ist gekennzeichnet und versorgt die Stromkreise Licht, Steckdosen innen und eine Außensteckdose mit Schutzart nach Wassereinwirkung. Mauerdurchführungen werden abgedichtet.","Vom Hauptverteiler zum Gartenhaus: Abgang, Erdkabel und Unterverteiler mit eigenen Stromkreisen. Werte für Schutzorgan und Querschnitt legt die Elektrofachkraft fest.","\u002Fimages\u002Fblog\u002Fdiagrams\u002Fgarden-house-garage-sub-board\u002Foutbuilding-supply.de.svg",[39,2015,2017],{"id":2016},"darf-das-kabel-an-der-fassade-oder-am-zaun-entlang-laufen","Darf das Kabel an der Fassade oder am Zaun entlang laufen?",[11,2019,2020,2021,129],{},"Im Freien und auf Putz dürfen nur Kabel verlegt werden; ausgenommen sind unabhängige Schutz- und Schutzpotentialausgleichsleiter sowie unabhängige geerdete aktive Leiter wie PEN (Unterabschnitt 5.2.9.5). Befestigungen müssen die Leitung unbeschädigt halten und den äußeren Einflüssen standhalten. Für Leitungen außerhalb von Gebäuden gelten die Regeln des Fachs unter Berücksichtigung der äußeren Einflüsse (Unterabschnitt 5.2.9.14). Ein Kabel an der Fassade erscheint im Eindrahtschema mit seiner Verlegeart; welche Kennbuchstaben es dafür gibt, erklärt ",[19,2022,2024],{"href":2023},"\u002Fde\u002Fblog\u002Fverlegearten-arei-eindrahtschema","Verlegearten nach AREI",[39,2026,2028],{"id":2027},"welche-schutzart-brauchen-steckdosen-und-leuchten-draußen","Welche Schutzart brauchen Steckdosen und Leuchten draußen?",[11,2030,2031],{},"Die Schutzart richtet sich nach der Wassereinwirkung am Einsatzort, die das AREI mit Codes AD1 bis AD8 beschreibt (Unterabschnitt 5.3.2.2, Tabelle 5.4). Die Einordnung des Orts macht die Elektrofachkraft.",[47,2033,2034,2046],{},[50,2035,2036],{},[53,2037,2038,2040,2043],{},[56,2039,252],{},[56,2041,2042],{},"Auftreten von Wasser",[56,2044,2045],{},"Mindestschutzart",[66,2047,2048,2057,2066,2075,2084],{},[53,2049,2050,2052,2055],{},[71,2051,265],{},[71,2053,2054],{},"vernachlässigbar",[71,2056,271],{},[53,2058,2059,2061,2064],{},[71,2060,276],{},[71,2062,2063],{},"Tropfwasser",[71,2065,282],{},[53,2067,2068,2070,2073],{},[71,2069,287],{},[71,2071,2072],{},"Sprühwasser",[71,2074,293],{},[53,2076,2077,2079,2082],{},[71,2078,298],{},[71,2080,2081],{},"Spritzwasser",[71,2083,304],{},[53,2085,2086,2088,2091],{},[71,2087,309],{},[71,2089,2090],{},"Strahlwasser",[71,2092,315],{},[11,2094,2095,2096,129],{},"Geräte für Außenbeleuchtung, die AD2 bis AD4 ausgesetzt sind, dürfen nicht der Klasse 0 oder 0I angehören (Unterabschnitt 5.3.4.2 h). Welcher Differenzialschalter die Steckdosen im Gartenhaus schützt, erklärt ",[19,2097,2099],{"href":2098},"\u002Fde\u002Fblog\u002F30ma-fi-pro-steckdose","30-mA-Differenzialschalter für jede Steckdose?",[39,2101,2103],{"id":2102},"wie-erscheint-der-unterverteiler-im-eindrahtschema-und-im-positionsplan","Wie erscheint der Unterverteiler im Eindrahtschema und im Positionsplan?",[47,2105,2106,2119],{},[50,2107,2108],{},[53,2109,2110,2113,2116],{},[56,2111,2112],{},"Wo",[56,2114,2115],{},"Was hinein gehört",[56,2117,2118],{},"Fundstelle",[66,2120,2121,2132,2143,2154,2165],{},[53,2122,2123,2126,2129],{},[71,2124,2125],{},"Eindrahtschema",[71,2127,2128],{},"Abgang im Hauptverteiler mit Schutzorgan, Zuleitung mit Typ, Querschnitt, Leiterzahl und Verlegeart, Unterverteiler mit seinen Stromkreisen, Schutzorganen und Verbrauchern",[71,2130,2131],{},"Unterabschnitt 3.1.2.2 a",[53,2133,2134,2137,2140],{},[71,2135,2136],{},"Kreisbezeichnung",[71,2138,2139],{},"Großbuchstabe je Stromkreis, Punkte ab dem Schutzorgan nummeriert",[71,2141,2142],{},"Unterabschnitt 3.1.2.1 a",[53,2144,2145,2148,2151],{},[71,2146,2147],{},"Positionsplan",[71,2149,2150],{},"Lage des Unterverteilers, der Steckdosen, Lichtpunkte, Schalter und ortsfesten Geräte im Nebengebäude",[71,2152,2153],{},"Unterabschnitt 3.1.2.3 a",[53,2155,2156,2159,2162],{},[71,2157,2158],{},"Am Verteiler selbst",[71,2160,2161],{},"Individuelle, wischfeste Kennzeichnung und die Versorgungsspannung",[71,2163,2164],{},"Unterabschnitt 3.1.3.3 a",[53,2166,2167,2170,2173],{},[71,2168,2169],{},"An den Schutzorganen",[71,2171,2172],{},"Jeder Stromkreis identifizierbar gekennzeichnet",[71,2174,2175],{},"Unterabschnitt 3.1.3.1",[11,2177,2178,2179,129],{},"Der Unterverteiler im Gartenhaus gehört zur selben Anlage wie das Haus, solange er am selben Zähler hängt. Er bekommt also kein eigenes Schema, sondern einen Abschnitt im Schema des Hauses. Mehr zur Gliederung von Haupt- und Unterverteilern steht in ",[19,2180,2182],{"href":2181},"\u002Fde\u002Fblog\u002Fmehrgeschossig-elektro-planen","Elektroplanung über mehrere Etagen",[39,2184,2186],{"id":2185},"muss-der-kabelweg-durch-den-garten-in-den-plan","Muss der Kabelweg durch den Garten in den Plan?",[11,2188,2189,2190,2192],{},"Für Wohnungen verlangt das AREI im Positionsplan die Lage von Verteilern, Dosen, Steckdosen, Lichtpunkten, Schaltern und ortsfesten Geräten (Unterabschnitt 3.1.2.3 a), nicht den Verlauf eines Erdkabels. Nur für nicht hauswirtschaftliche Anlagen müssen Eigentümer unterirdischer Leitungen deren Pläne oder die Angaben zu ihrer Lokalisierung bereithalten (Unterabschnitt 3.1.2.1 b). Den Kabelweg trotzdem einzuzeichnen, mit Tiefe und Lage des Kabelrohrs, ist eine gute Gewohnheit: Wer später einen Zaun setzt, einen Baum pflanzt oder eine Terrasse baut, weiß, wo nicht gegraben werden darf. In Sketch reicht dafür das Werkzeug ",[14,2191,1544],{}," im Positionsplan an der Stelle, an der das Kabel das Haus verlässt.",[39,2194,2196],{"id":2195},"ist-das-eine-wesentliche-erweiterung","Ist das eine wesentliche Erweiterung?",[11,2198,2199],{},"Wesentlich ist eine Änderung oder Erweiterung, die eine zusätzliche, noch nicht durch eine Konformitätsprüfung abgedeckte Auswirkung auf die Sicherheit von Personen oder Gütern hat (Abschnitt 2.11.2). Ein neuer Abgang mit Erdkabel und eigenem Verteiler bringt neue Schutzorgane und Leitungen; kläre die Einordnung mit deiner Elektrofachkraft.",[47,2201,2202,2215],{},[50,2203,2204],{},[53,2205,2206,2209,2212],{},[56,2207,2208],{},"Einordnung",[56,2210,2211],{},"Pläne",[56,2213,2214],{},"Prüfung",[66,2216,2217,2228],{},[53,2218,2219,2222,2225],{},[71,2220,2221],{},"Wesentlich",[71,2223,2224],{},"Eindrahtschema und Positionsplan erstellen oder aktualisieren (Unterabschnitt 3.1.2.1 a)",[71,2226,2227],{},"Konformitätsprüfung der hinzugefügten und geänderten Teile vor Ingebrauchnahme (Unterabschnitt 6.4.7.3)",[53,2229,2230,2233,2236],{},[71,2231,2232],{},"Unwesentlich",[71,2234,2235],{},"Kurze, datierte und unterschriebene Beschreibung; der Positionsplan zeigt die Änderung (Unterabschnitt 3.1.2.1 a)",[71,2237,2238],{},"keine Konformitätsprüfung vor Ingebrauchnahme vorgeschrieben",[11,2240,2241,2242,129],{},"Welche Folgen Umbauten an bestehenden Anlagen haben, beschreibt ",[19,2243,2245],{"href":2244},"\u002Fde\u002Fblog\u002Frenovierung-arei-elektroplaene","Renovierung und AREI",[39,2247,2249],{"id":2248},"wie-zeichne-ich-gartenhaus-und-unterverteiler-in-planelec-sketch","Wie zeichne ich Gartenhaus und Unterverteiler in PlanElec Sketch?",[475,2251,2252,2260,2270,2276,2286],{},[478,2253,2254,2255,2259],{},"Öffne ",[19,2256,2258],{"href":1824,"rel":2257},[23],"Sketch mit „Unterlagen für die Kontrolle zeichnen“"," oder deine vorhandene Zeichnung des Hauses. Ohne Konto bleibt die Zeichnung im Browser.",[478,2261,2262,2263,2265,2266,2269],{},"Füge im ",[14,2264,2125],{}," am Hauptverteiler den Abgang zum Gartenhaus hinzu und setze den ",[14,2267,2268],{},"Unterverteiler"," aus der Bibliothek auf das Kabel dieses Abgangs. Am Unterverteiler hängst du die Stromkreise für Licht und Steckdosen an; Kreisbuchstaben und Nummern vergibt Sketch.",[478,2271,2272,2273,129],{},"Trage am Kabel der Zuleitung Typ, Querschnitt, Verlegung und Länge ein, sobald die Elektrofachkraft sie festgelegt hat; Sketch schreibt sie ans Kabel im Schema. Bis dahin hilft eine ",[14,2274,2275],{},"Notiz",[478,2277,2278,2279,2281,2282,2285],{},"Lege im ",[14,2280,2147],{}," für das Nebengebäude eine eigene Etage an (",[14,2283,2284],{},"Etage hinzufügen",", etwa „Gartenhaus“) und ziehe Unterverteiler, Leuchten und Steckdosen an ihren Platz.",[478,2287,2288,2291,2292,129],{},[14,2289,2290],{},"Unterlagen prüfen"," zeigt, was noch fehlt, etwa Geräte ohne Platz im Positionsplan. Dann ",[14,2293,2294],{},"PDF erstellen",[219,2296],{":height":523,":width":524,"alt":2297,"caption":2298,"src":2299},"„Positionsplan“ in PlanElec Sketch mit den Etagenreitern Erdgeschoss, Obergeschoss und Dachgeschoss; im Raum stehen Schalter, Leuchten und Steckdosen mit Kreisbezeichnung, links die Palette „Aus dem Eindrahtschema“ mit Haken an den platzierten Kreisen.","Jede Etage ist ein eigenes Blatt im PDF; ein Nebengebäude bekommt eine eigene Etage. Die Palette zeigt, welche Geräte aus dem Schema schon einen Platz haben.","\u002Fimages\u002Fblog\u002Fscreens\u002Fsketch\u002Fde-situation-floors.webp",[11,2301,2302,2303,129],{},"Sketch ist gratis; ohne Konto trägt das PDF ein Logo-Wasserzeichen, ein kostenloses Konto entfernt es. Alle Grenzen stehen auf der ",[19,2304,2306],{"href":2305},"\u002Fde\u002Fpricing","Preisseite",[39,2308,2310],{"id":2309},"sketch-oder-pro-was-brauchst-du","Sketch oder Pro: Was brauchst du?",[47,2312,2313,2323],{},[50,2314,2315],{},[53,2316,2317,2320],{},[56,2318,2319],{},"Deine Situation",[56,2321,2322],{},"Werkzeug",[66,2324,2325,2335,2344,2357],{},[53,2326,2327,2330],{},[71,2328,2329],{},"Eigentümer, der die Erweiterung für das Gespräch mit dem Elektriker skizziert",[71,2331,2332,2334],{},[14,2333,562],{},", gratis",[53,2336,2337,2340],{},[71,2338,2339],{},"Elektriker, der Eindrahtschema und Positionsplan der Erweiterung abgibt",[71,2341,2342],{},[14,2343,562],{},[53,2345,2346,2349],{},[71,2347,2348],{},"Betrieb, der Unterverteiler und Hauptverteiler im Schaltschrank-Editor belegt und einen Selbstprüfbericht braucht",[71,2350,2351,2353,2354],{},[14,2352,582],{},", Übernahme aus Sketch mit ",[14,2355,2356],{},"In Pro übernehmen",[53,2358,2359,2362],{},[71,2360,2361],{},"Kabelwege und -längen aus dem Grundriss für die Materialliste",[71,2363,2364],{},[14,2365,582],{},[11,2367,2368,2369,2373,2374,129],{},"Was Pro mit Schaltschrankplanung, Kabelwegen und Selbstprüfung zusätzlich kann, zeigt die ",[19,2370,2372],{"href":2371},"\u002Fde\u002Fprodukte\u002Fpro","Produktseite von PlanElec Pro","; wie Kabelwege dort entstehen, erklärt die Hilfe ",[19,2375,2377],{"href":2376},"\u002Fde\u002Fhelp\u002Fschalterketten-stromkreise-und-kabelwege","Schalterketten, Stromkreise und Kabelwege",[39,2379,2381],{"id":2380},"grenzen","Grenzen",[11,2383,2384],{},"Dieser Artikel nennt die AREI-Anforderungen an Erdkabel, Verlegung im Freien, Schutzart und Dokumentation. Er bemisst keine Leitung, wählt kein Schutzorgan und ordnet keinen Ort einem AD-Code zu; das macht die Elektrofachkraft. Sketch prüft keine AREI-Regeln. Ob die Erweiterung konform ist, stellt die zugelassene Kontrollstelle fest.",[39,2386,2388],{"id":2387},"amtliche-quelle-und-weiterführende-artikel","Amtliche Quelle und weiterführende Artikel",[620,2390,2391,2399,2405,2411,2417],{},[478,2392,2393,2398],{},[19,2394,2397],{"href":2395,"rel":2396},"https:\u002F\u002Feconomie.fgov.be\u002Fde\u002Fpublication\u002Fallgemeine-vorschriften-fuer",[23],"FÖD Wirtschaft: Allgemeine Vorschriften für elektrische Anlagen, Buch 1"," – Abschnitt 2.11.2, Unterabschnitte 3.1.2.1 a, 3.1.2.2 a, 3.1.2.3 a, 3.1.3.1, 3.1.3.3 a, 5.2.9.2, 5.2.9.5, 5.2.9.14, 5.3.2.2, 5.3.4.2 h und 6.4.7.3",[478,2400,2401],{},[19,2402,2404],{"href":2403},"\u002Fde\u002Fblog\u002Fschaltschrank-planen-aufbau","Schaltschrank planen: Aufbau und Dimensionierung nach AREI",[478,2406,2407],{},[19,2408,2410],{"href":2409},"\u002Fde\u002Fblog\u002Fkabelwege-und-leitungslaengen-ermitteln","Kabelwege und Leitungslängen ermitteln",[478,2412,2413],{},[19,2414,2416],{"href":2415},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema erstellen: Schritt für Schritt nach AREI",[478,2418,2419],{},[19,2420,2422],{"href":2421},"\u002Fde\u002Fblog\u002Feindrahtschema-bestehende-installation-aufnehmen","Eindrahtschema einer bestehenden Installation zeichnen",[11,2424,2425],{},[19,2426,2428],{"href":1824,"rel":2427},[23],"Gartenhaus und Unterverteiler jetzt gratis in PlanElec Sketch zeichnen →",{"title":661,"searchDepth":662,"depth":662,"links":2430},[2431,2432,2433,2434,2435,2436,2437,2438,2439,2440,2441],{"id":1839,"depth":662,"text":1840},{"id":1923,"depth":662,"text":1924},{"id":2016,"depth":662,"text":2017},{"id":2027,"depth":662,"text":2028},{"id":2102,"depth":662,"text":2103},{"id":2185,"depth":662,"text":2186},{"id":2195,"depth":662,"text":2196},{"id":2248,"depth":662,"text":2249},{"id":2309,"depth":662,"text":2310},{"id":2380,"depth":662,"text":2381},{"id":2387,"depth":662,"text":2388},"Erdkabel mindestens 0,60 m tief oder mechanisch geschützt, Unterverteiler gekennzeichnet und im Positionsplan, Schutzart nach Wassereinwirkung: So planst du die Versorgung von Gartenhaus, Garage oder Carport nach AREI und zeichnest sie in PlanElec Sketch.",[680,681,682,683],"de",{},"\u002Fblog\u002Fgartenhaus-garage-unterverteiler-eindrahtschema.de",{"title":1813,"description":2442},"Gartenhaus und Garage: Erdkabel und Unterverteiler","gartenhaus-garage-unterverteiler-eindrahtschema","blog\u002Fgartenhaus-garage-unterverteiler-eindrahtschema.de",[2452,2453,2454,2455,2456,2457,2458,704,703,2459,24,2460],"Strom Gartenhaus","Erdkabel Gartenhaus","Unterverteiler Garage","Erdkabel Tiefe","Außensteckdose IP","Nebengebäude Elektro","Eindrahtschema Unterverteiler","Eendraadschema","Belgien","vVwE_UPE4b1gKgTOB_rCVxZaxsezVcfHxKZwkRFyqQg",{"id":2463,"title":2464,"articleId":6,"body":2465,"category":675,"date":676,"description":3089,"extension":678,"image":32,"labels":3090,"lastUpdated":676,"locale":3091,"meta":3092,"navigation":686,"ogImage":687,"path":3093,"publishDate":676,"readTime":689,"refreshInterval":690,"seo":3094,"seoTitle":3095,"slug":3096,"stem":3097,"tags":3098,"__hash__":3108},"blog\u002Fblog\u002Ftuinhuis-garage-onderverdeelbord-eendraadschema.nl.md","Elektriciteit naar het tuinhuis of de garage: hoe plan en teken ik ingegraven kabel en onderverdeelbord volgens het AREI?",{"type":8,"value":2466,"toc":3076},[2467,2478,2483,2488,2492,2495,2560,2572,2576,2579,2648,2660,2665,2669,2676,2680,2683,2744,2751,2755,2826,2833,2837,2844,2848,2851,2890,2897,2901,2946,2951,2958,2962,3015,3027,3029,3032,3036,3070],[11,2468,2469,2472,2473,2477],{},[14,2470,2471],{},"Een tuinhuis, een vrijstaande garage of een carport krijgt stroom via een eigen vertrekkende kring in het hoofdverdeelbord, een ingegraven kabel en, zodra er meerdere stroomkringen nodig zijn, een onderverdeelbord."," Het AREI vraagt voor de ingegraven kabel een minimale diepte van 0,60 m of, waar dat technisch niet kan, een doorlopende mechanische bescherming (onderafdeling 5.2.9.2 a). Het onderverdeelbord wordt geïdentificeerd (onderafdeling 3.1.3.3 a), staat met zijn plaats op het situatieschema (onderafdeling 3.1.2.3 a) en krijgt op het eendraadschema een eigen deel. Tekenen kan gratis in ",[19,2474,24],{"href":2475,"rel":2476},"https:\u002F\u002Fsketch.planelec.be\u002Fnl\u002Ftekenen?start=keuring",[23],"; uitvoering, dimensionering en keuring blijven de taak van de elektricien en het erkend organisme.",[11,2479,2480],{},[29,2481],{"alt":2482,"src":32},"Een elektricien plant in een Belgische tuin de verbinding naar het tuinhuis en de garage met een gesloten onderverdeelbord.",[11,2484,2485],{},[14,2486,2487],{},"Stand van 7 november 2026, AREI Boek 1 versie 07. Geschreven door het PlanElec-team, dat Sketch en Pro maakt.",[39,2489,2491],{"id":2490},"heb-ik-een-onderverdeelbord-nodig-of-volstaat-één-stroomkring","Heb ik een onderverdeelbord nodig, of volstaat één stroomkring?",[11,2493,2494],{},"Dat hangt af van wat er in het bijgebouw komt. Het AREI schrijft geen onderverdeelbord voor; het schrijft voor hoe stroomkringen, leidingen en borden uitgevoerd en gedocumenteerd worden.",[47,2496,2497,2510],{},[50,2498,2499],{},[53,2500,2501,2504,2507],{},[56,2502,2503],{},"Gebruik in het bijgebouw",[56,2505,2506],{},"Typische oplossing",[56,2508,2509],{},"Wat op het schema komt",[66,2511,2512,2523,2534,2549],{},[53,2513,2514,2517,2520],{},[71,2515,2516],{},"Eén lichtpunt en één stopcontact in het tuinhuis",[71,2518,2519],{},"Eén eindkring vanuit het hoofdverdeelbord",[71,2521,2522],{},"Eén stroomkring met letter, beveiliging en grondkabel",[53,2524,2525,2528,2531],{},[71,2526,2527],{},"Licht, meerdere stopcontacten, werkbank in de garage",[71,2529,2530],{},"Voedingskabel naar een onderverdeelbord met eigen kringen",[71,2532,2533],{},"Vertrek in het hoofdbord, voedingskabel, onderverdeelbord met kringen",[53,2535,2536,2539,2546],{},[71,2537,2538],{},"Laadpunt voor een elektrische wagen onder de carport",[71,2540,2541,2542],{},"Eigen stroomkring; details in ",[19,2543,2545],{"href":2544},"\u002Fblog\u002Flaadpaal-arei","Laadpaal volgens het AREI",[71,2547,2548],{},"Eigen stroomkring met laadpunt",[53,2550,2551,2554,2557],{},[71,2552,2553],{},"Pomp voor vijver of put",[71,2555,2556],{},"Toestel met vaste plaats, vaak een eigen kring",[71,2558,2559],{},"Stroomkring met vast toestel",[11,2561,2562,2563,2567,2568,129],{},"Voor stopcontacten geldt dezelfde grens als in huis: hoogstens acht enkele of meervoudige stopcontacten per eindkring (onderafdeling 5.3.5.2 b, zie ",[19,2564,2566],{"href":2565},"\u002Fblog\u002Fstopcontacten-per-circuit","Hoeveel stopcontacten per stroomkring?","). Welke toestellen een eigen kring nodig hebben, lees je in ",[19,2569,2571],{"href":2570},"\u002Fblog\u002Feigen-stroomkring-verplicht-toestellen","Eigen stroomkring verplicht",[39,2573,2575],{"id":2574},"hoe-diep-moet-de-kabel-naar-het-tuinhuis-liggen","Hoe diep moet de kabel naar het tuinhuis liggen?",[11,2577,2578],{},"Onderafdeling 5.2.9.2 a regelt ondergrondse leidingen:",[47,2580,2581,2591],{},[50,2582,2583],{},[53,2584,2585,2588],{},[56,2586,2587],{},"Vereiste",[56,2589,2590],{},"Inhoud",[66,2592,2593,2601,2609,2617,2632,2640],{},[53,2594,2595,2598],{},[71,2596,2597],{},"Alleen geschikte kabels",[71,2599,2600],{},"In de grond en in ontoegankelijke ondergrondse buizen alleen kabels volgens de normen die daarvoor gelden (uitzondering: onafhankelijke beschermingsgeleiders)",[53,2602,2603,2606],{},[71,2604,2605],{},"Minimale diepte",[71,2607,2608],{},"0,60 m onder het grondvlak (maaiveld, bovenkant van tegels of wegdek), behalve als dat technisch onmogelijk is",[53,2610,2611,2614],{},[71,2612,2613],{},"Als 0,60 m niet haalbaar is",[71,2615,2616],{},"Bescherming door een doorlopend omhulsel of een evenwaardig systeem in duurzaam, weerstandbiedend materiaal",[53,2618,2619,2622],{},[71,2620,2621],{},"Bescherming van de kabel (één van drie voorwaarden)",[71,2623,2624,2625,2628,2629,2631],{},"geaard scherm en wapening of versterkte buitenmantel; ",[14,2626,2627],{},"of"," weerstandbiedende buitenmantel plus doorlopende afdekking boven de kabel tegen gereedschap; ",[14,2630,2627],{}," plaatsing in een buis",[53,2633,2634,2637],{},[71,2635,2636],{},"Doorgang door een muur",[71,2638,2639],{},"Opening na de plaatsing zorgvuldig dichten (onderafdeling 5.2.9.2 b)",[53,2641,2642,2645],{},[71,2643,2644],{},"Telecommunicatiekabels",[71,2646,2647],{},"Minstens 0,50 m afstand tot bestaande telecommunicatiekabels (onderafdeling 5.2.9.2 c.1)",[11,2649,2650,2651,2655,2656,129],{},"Welke kabel aan de voorwaarden voldoet en welke doorsnede nodig is, bepaalt de elektricien. Lange afstanden door de tuin maken de spanningsval belangrijk; hoe je die inschat, lees je in ",[19,2652,2654],{"href":2653},"\u002Fblog\u002Fspanningsval-berekenen-kabeldoorsnede","Spanningsval berekenen",", de koppeling tussen doorsnede en beveiliging in ",[19,2657,2659],{"href":2658},"\u002Fblog\u002Fkabeldoorsnede-automaat","Kabeldoorsnede en automaat",[219,2661],{":height":221,":width":222,"alt":2662,"caption":2663,"src":2664},"Schema van de voeding van een tuinhuis: in het hoofdverdeelbord zit een vertrekkende kring met beveiliging. Van daar loopt een ingegraven kabel, minstens 0,60 m diep of doorlopend mechanisch beschermd, naar het onderverdeelbord in het tuinhuis. Het onderverdeelbord is geïdentificeerd en voedt de kringen verlichting, stopcontacten binnen en een buitenstopcontact met beschermingsgraad volgens de waterinvloed. Muurdoorgangen worden gedicht.","Van hoofdverdeelbord naar tuinhuis: vertrek, ingegraven kabel en onderverdeelbord met eigen kringen. Waarden voor beveiliging en doorsnede bepaalt de elektricien.","\u002Fimages\u002Fblog\u002Fdiagrams\u002Fgarden-house-garage-sub-board\u002Foutbuilding-supply.nl.svg",[39,2666,2668],{"id":2667},"mag-de-kabel-langs-de-gevel-of-de-omheining-lopen","Mag de kabel langs de gevel of de omheining lopen?",[11,2670,2671,2672,129],{},"In open lucht en in opbouw mogen alleen kabels geplaatst worden; uitgezonderd zijn onafhankelijke beschermings- en potentiaalvereffeningsgeleiders en onafhankelijke geaarde actieve geleiders zoals PEN (onderafdeling 5.2.9.5). Bevestigingen moeten de leiding onbeschadigd houden en bestand zijn tegen de uitwendige invloeden. Voor leidingen buiten gebouwen gelden de regels van goed vakmanschap, rekening houdend met de uitwendige invloeden (onderafdeling 5.2.9.14). Een kabel langs de gevel staat op het eendraadschema met zijn plaatsingswijze; welke codes daarvoor bestaan, lees je in ",[19,2673,2675],{"href":2674},"\u002Fblog\u002Fplaatsingswijzen-arei-eendraadschema","Plaatsingswijzen volgens het AREI",[39,2677,2679],{"id":2678},"welke-beschermingsgraad-hebben-buitenstopcontacten-en-buitenlampen-nodig","Welke beschermingsgraad hebben buitenstopcontacten en buitenlampen nodig?",[11,2681,2682],{},"De beschermingsgraad hangt af van de aanwezigheid van water op de plaats van gebruik, die het AREI beschrijft met de codes AD1 tot AD8 (onderafdeling 5.3.2.2, tabel 5.4). De indeling van de plaats doet de elektricien.",[47,2684,2685,2697],{},[50,2686,2687],{},[53,2688,2689,2691,2694],{},[56,2690,252],{},[56,2692,2693],{},"Aanwezigheid van water",[56,2695,2696],{},"Minimale beschermingsgraad",[66,2698,2699,2708,2717,2726,2735],{},[53,2700,2701,2703,2706],{},[71,2702,265],{},[71,2704,2705],{},"te verwaarlozen",[71,2707,271],{},[53,2709,2710,2712,2715],{},[71,2711,276],{},[71,2713,2714],{},"tijdelijk vochtig",[71,2716,282],{},[53,2718,2719,2721,2724],{},[71,2720,287],{},[71,2722,2723],{},"vochtig",[71,2725,293],{},[53,2727,2728,2730,2733],{},[71,2729,298],{},[71,2731,2732],{},"nat",[71,2734,304],{},[53,2736,2737,2739,2742],{},[71,2738,309],{},[71,2740,2741],{},"besproeid",[71,2743,315],{},[11,2745,2746,2747,129],{},"Buitenverlichtingstoestellen in de invloedsvoorwaarden AD2 tot en met AD4 mogen niet van klasse 0 of 0I zijn (onderafdeling 5.3.4.2 h). Welke differentieelschakelaar de stopcontacten in het tuinhuis beschermt, lees je in ",[19,2748,2750],{"href":2749},"\u002Fblog\u002F30ma-aardlek-per-stopcontact","30 mA differentieel per stopcontact?",[39,2752,2754],{"id":2753},"hoe-staat-het-onderverdeelbord-op-het-eendraadschema-en-het-situatieschema","Hoe staat het onderverdeelbord op het eendraadschema en het situatieschema?",[47,2756,2757,2770],{},[50,2758,2759],{},[53,2760,2761,2764,2767],{},[56,2762,2763],{},"Waar",[56,2765,2766],{},"Wat erop hoort",[56,2768,2769],{},"Verwijzing",[66,2771,2772,2782,2793,2804,2815],{},[53,2773,2774,2776,2779],{},[71,2775,2459],{},[71,2777,2778],{},"Vertrek in het hoofdbord met beveiliging, voedingskabel met type, doorsnede, aantal geleiders en plaatsingswijze, onderverdeelbord met zijn kringen, beveiligingen en verbruikers",[71,2780,2781],{},"onderafdeling 3.1.2.2 a",[53,2783,2784,2787,2790],{},[71,2785,2786],{},"Kringaanduiding",[71,2788,2789],{},"Hoofdletter per stroomkring, punten genummerd vanaf de beveiliging",[71,2791,2792],{},"onderafdeling 3.1.2.1 a",[53,2794,2795,2798,2801],{},[71,2796,2797],{},"Situatieschema",[71,2799,2800],{},"Plaats van het onderverdeelbord, de stopcontacten, lichtpunten, schakelaars en vaste toestellen in het bijgebouw",[71,2802,2803],{},"onderafdeling 3.1.2.3 a",[53,2805,2806,2809,2812],{},[71,2807,2808],{},"Op het bord zelf",[71,2810,2811],{},"Individuele, onuitwisbare identificatie en de voedingsspanning",[71,2813,2814],{},"onderafdeling 3.1.3.3 a",[53,2816,2817,2820,2823],{},[71,2818,2819],{},"Bij de beveiligingen",[71,2821,2822],{},"Elke stroomkring herkenbaar aangeduid",[71,2824,2825],{},"onderafdeling 3.1.3.1",[11,2827,2828,2829,129],{},"Het onderverdeelbord in het tuinhuis hoort bij dezelfde installatie als het huis, zolang het aan dezelfde meter hangt. Het krijgt dus geen eigen schema, maar een eigen deel in het schema van het huis. Meer over de opbouw van hoofd- en onderverdeelborden lees je in ",[19,2830,2832],{"href":2831},"\u002Fblog\u002Fmeerdere-verdiepingen-elektriciteit-plannen","Elektriciteit plannen over meerdere verdiepingen",[39,2834,2836],{"id":2835},"moet-het-kabeltracé-door-de-tuin-op-het-plan","Moet het kabeltracé door de tuin op het plan?",[11,2838,2839,2840,2843],{},"Voor woningen vraagt het AREI op het situatieschema de plaats van borden, dozen, stopcontacten, lichtpunten, schakelaars en vaste toestellen (onderafdeling 3.1.2.3 a), niet het tracé van een ingegraven kabel. Alleen voor niet-huishoudelijke installaties moeten eigenaars van ondergrondse leidingen de plannen of de gegevens voor hun lokalisatie ter beschikking houden (onderafdeling 3.1.2.1 b). Het tracé toch intekenen, met diepte en ligging van de buis, is een goede gewoonte: wie later een omheining plaatst, een boom plant of een terras aanlegt, weet waar niet gegraven mag worden. In Sketch volstaat daarvoor het gereedschap ",[14,2841,2842],{},"Tekst"," op het situatieplan op de plaats waar de kabel het huis verlaat.",[39,2845,2847],{"id":2846},"is-dit-een-belangrijke-uitbreiding","Is dit een belangrijke uitbreiding?",[11,2849,2850],{},"Belangrijk is een wijziging of uitbreiding met een bijkomende, nog niet door een gelijkvormigheidsonderzoek gedekte invloed op de veiligheid van personen of goederen (afdeling 2.11.2). Een nieuw vertrek met grondkabel en eigen bord brengt nieuwe beveiligingen en leidingen mee; bespreek de indeling met je elektricien.",[47,2852,2853,2866],{},[50,2854,2855],{},[53,2856,2857,2860,2863],{},[56,2858,2859],{},"Indeling",[56,2861,2862],{},"Plannen",[56,2864,2865],{},"Keuring",[66,2867,2868,2879],{},[53,2869,2870,2873,2876],{},[71,2871,2872],{},"Belangrijk",[71,2874,2875],{},"Eendraadschema en situatieschema opmaken of bijwerken (onderafdeling 3.1.2.1 a)",[71,2877,2878],{},"Gelijkvormigheidsonderzoek van de toegevoegde en gewijzigde delen vóór ingebruikname (onderafdeling 6.4.7.3)",[53,2880,2881,2884,2887],{},[71,2882,2883],{},"Niet belangrijk",[71,2885,2886],{},"Korte, gedateerde en ondertekende beschrijving; het situatieschema toont de wijziging (onderafdeling 3.1.2.1 a)",[71,2888,2889],{},"geen gelijkvormigheidsonderzoek vóór ingebruikname voorgeschreven",[11,2891,2892,2893,129],{},"Welke gevolgen verbouwingen aan bestaande installaties hebben, lees je in ",[19,2894,2896],{"href":2895},"\u002Fblog\u002Frenovatie-arei-elektrische-plannen","Renovatie en AREI",[39,2898,2900],{"id":2899},"hoe-teken-ik-tuinhuis-en-onderverdeelbord-in-planelec-sketch","Hoe teken ik tuinhuis en onderverdeelbord in PlanElec Sketch?",[475,2902,2903,2910,2920,2926,2937],{},[478,2904,1606,2905,2909],{},[19,2906,2908],{"href":2475,"rel":2907},[23],"Sketch met ‘Documenten voor de keuring tekenen’"," of je bestaande tekening van het huis. Zonder account blijft de tekening in de browser.",[478,2911,2912,2913,2915,2916,2919],{},"Voeg in het ",[14,2914,2459],{}," aan het hoofdbord het vertrek naar het tuinhuis toe en zet het ",[14,2917,2918],{},"Onderverdeelbord"," uit de bibliotheek op de kabel van dat vertrek. Aan het onderverdeelbord hang je de kringen voor licht en stopcontacten; kringletters en nummers kent Sketch toe.",[478,2921,2922,2923,129],{},"Vul op de voedingskabel type, doorsnede, plaatsing en lengte in zodra de elektricien ze bepaald heeft; Sketch schrijft ze bij de kabel op het schema. Tot dan helpt een ",[14,2924,2925],{},"notitie",[478,2927,2928,2929,2932,2933,2936],{},"Maak in het ",[14,2930,2931],{},"Situatieplan"," een eigen verdieping voor het bijgebouw (",[14,2934,2935],{},"Verdieping toevoegen",", bijvoorbeeld ‘Tuinhuis’) en sleep onderverdeelbord, lampen en stopcontacten naar hun plaats.",[478,2938,2939,2942,2943,129],{},[14,2940,2941],{},"Documenten nakijken"," toont wat nog ontbreekt, zoals toestellen zonder plaats op het situatieplan. Daarna ",[14,2944,2945],{},"Pdf maken",[219,2947],{":height":523,":width":524,"alt":2948,"caption":2949,"src":2950},"‘Situatieplan’ in PlanElec Sketch met de verdiepingstabs Gelijkvloers, Verdieping en Zolder; in de ruimte staan schakelaars, lampen en stopcontacten met kringaanduiding, links het palet ‘Uit het eendraadschema’ met vinkjes bij de geplaatste kringen.","Elke verdieping is een eigen blad in de pdf; een bijgebouw krijgt een eigen verdieping. Het palet toont welke toestellen uit het schema al een plaats hebben.","\u002Fimages\u002Fblog\u002Fscreens\u002Fsketch\u002Fnl-situation-floors.webp",[11,2952,2953,2954,129],{},"Sketch is gratis; zonder account draagt de pdf een logo-watermerk, een gratis account haalt het weg. Alle grenzen staan op de ",[19,2955,2957],{"href":2956},"\u002Fpricing","prijspagina",[39,2959,2961],{"id":2960},"sketch-of-pro-wat-heb-je-nodig","Sketch of Pro: wat heb je nodig?",[47,2963,2964,2973],{},[50,2965,2966],{},[53,2967,2968,2971],{},[56,2969,2970],{},"Jouw situatie",[56,2972,1673],{},[66,2974,2975,2984,2993,3006],{},[53,2976,2977,2980],{},[71,2978,2979],{},"Eigenaar die de uitbreiding schetst voor het gesprek met de elektricien",[71,2981,2982,2334],{},[14,2983,562],{},[53,2985,2986,2989],{},[71,2987,2988],{},"Elektricien die eendraadschema en situatieschema van de uitbreiding oplevert",[71,2990,2991],{},[14,2992,562],{},[53,2994,2995,2998],{},[71,2996,2997],{},"Bedrijf dat onder- en hoofdverdeelbord in de verdeelbordeditor indeelt en een zelfcontroleverslag nodig heeft",[71,2999,3000,3002,3003],{},[14,3001,582],{},", overname uit Sketch met ",[14,3004,3005],{},"Overnemen in Pro",[53,3007,3008,3011],{},[71,3009,3010],{},"Kabelwegen en -lengtes uit het grondplan voor de materiaallijst",[71,3012,3013],{},[14,3014,582],{},[11,3016,3017,3018,3022,3023,129],{},"Wat Pro met verdeelbordplanning, kabelwegen en zelfcontrole meer kan, toont de ",[19,3019,3021],{"href":3020},"\u002Fproducten\u002Fpro","productpagina van PlanElec Pro","; hoe kabelwegen daar ontstaan, lees je in de hulp ",[19,3024,3026],{"href":3025},"\u002Fhelp\u002Fschakelketens-stroomkringen-en-kabelroutes","Schakelketens, stroomkringen en kabelroutes",[39,3028,2381],{"id":2380},[11,3030,3031],{},"Dit artikel noemt de AREI-vereisten voor ingegraven kabels, plaatsing in open lucht, beschermingsgraad en documentatie. Het dimensioneert geen leiding, kiest geen beveiliging en deelt geen plaats in bij een AD-code; dat doet de elektricien. Sketch controleert geen AREI-regels. Of de uitbreiding conform is, stelt het erkend organisme vast.",[39,3033,3035],{"id":3034},"officiële-bron-en-verder-lezen","Officiële bron en verder lezen",[620,3037,3038,3046,3052,3058,3064],{},[478,3039,3040,3045],{},[19,3041,3044],{"href":3042,"rel":3043},"https:\u002F\u002Feconomie.fgov.be\u002Fnl\u002Fpublicaties\u002Falgemeen-reglement-op-de",[23],"FOD Economie: Algemeen Reglement op de Elektrische Installaties, Boek 1"," – afdeling 2.11.2, onderafdelingen 3.1.2.1 a, 3.1.2.2 a, 3.1.2.3 a, 3.1.3.1, 3.1.3.3 a, 5.2.9.2, 5.2.9.5, 5.2.9.14, 5.3.2.2, 5.3.4.2 h en 6.4.7.3",[478,3047,3048],{},[19,3049,3051],{"href":3050},"\u002Fblog\u002Fverdeelkast-plannen-opbouw","Verdeelkast plannen: opbouw en dimensionering",[478,3053,3054],{},[19,3055,3057],{"href":3056},"\u002Fblog\u002Fkabelwegen-en-kabellengtes-bepalen","Kabelwegen en kabellengtes bepalen",[478,3059,3060],{},[19,3061,3063],{"href":3062},"\u002Fblog\u002Feendraadschema-maken","Eendraadschema maken: stap voor stap volgens het AREI",[478,3065,3066],{},[19,3067,3069],{"href":3068},"\u002Fblog\u002Feendraadschema-bestaande-installatie-opmaken","Eendraadschema van een bestaande installatie tekenen",[11,3071,3072],{},[19,3073,3075],{"href":2475,"rel":3074},[23],"Teken tuinhuis en onderverdeelbord nu gratis in PlanElec Sketch →",{"title":661,"searchDepth":662,"depth":662,"links":3077},[3078,3079,3080,3081,3082,3083,3084,3085,3086,3087,3088],{"id":2490,"depth":662,"text":2491},{"id":2574,"depth":662,"text":2575},{"id":2667,"depth":662,"text":2668},{"id":2678,"depth":662,"text":2679},{"id":2753,"depth":662,"text":2754},{"id":2835,"depth":662,"text":2836},{"id":2846,"depth":662,"text":2847},{"id":2899,"depth":662,"text":2900},{"id":2960,"depth":662,"text":2961},{"id":2380,"depth":662,"text":2381},{"id":3034,"depth":662,"text":3035},"Ingegraven kabel minstens 0,60 m diep of mechanisch beschermd, onderverdeelbord geïdentificeerd en op het situatieschema, beschermingsgraad volgens waterinvloed: zo plan je de voeding van tuinhuis, garage of carport volgens het AREI en teken je ze in PlanElec Sketch.",[680,681,682,683],"nl",{},"\u002Fblog\u002Ftuinhuis-garage-onderverdeelbord-eendraadschema.nl",{"title":2464,"description":3089},"Tuinhuis en garage: grondkabel en onderverdeelbord","tuinhuis-garage-onderverdeelbord-eendraadschema","blog\u002Ftuinhuis-garage-onderverdeelbord-eendraadschema.nl",[3099,3100,3101,3102,3103,3104,3105,704,703,3106,24,3107],"elektriciteit tuinhuis","kabel naar tuinhuis","onderverdeelbord garage","grondkabel diepte","buitenstopcontact IP","bijgebouw elektriciteit","eendraadschema onderverdeelbord","situatieschema","België","OW0MRU2gvN_ofgkdBrk6rJFIDzOtb4AVPQf0Hg1FzMA",[3110,3115,3120],{"articleId":3111,"locale":684,"slug":3112,"title":3113,"date":3114,"publishDate":3114},"xvb-vs-vob-cable","cable-xvb-vs-vob","Câble VOB ou XVB : différences, pose et choix en Belgique","2026-03-16",{"articleId":3116,"locale":684,"slug":3117,"title":3118,"date":3119,"publishDate":3119},"voltage-drop-cable-sizing","chute-de-tension-section-cable","Calculer la chute de tension : quelle longueur de câble ?","2026-08-02",{"articleId":3121,"locale":684,"slug":3122,"title":3123,"date":3124,"publishDate":3124},"distribution-board-planning","planifier-tableau-electrique","Planifier un tableau électrique : Conception et dimensionnement selon le RGIE","2026-04-07"]