[{"data":1,"prerenderedAt":1959},["ShallowReactive",2],{"blog-post-fr-cables-salle-de-bain-rgie":3,"blog-alternates-bathroom-cables-arei-zones":451},{"id":4,"title":5,"articleId":6,"body":7,"category":420,"date":421,"description":422,"extension":423,"lastUpdated":421,"locale":424,"meta":425,"navigation":426,"path":427,"publishDate":421,"readTime":428,"refreshInterval":429,"seo":430,"slug":431,"stem":432,"tags":433,"__hash__":450},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.fr.md","Quels câbles utiliser dans la salle de bain ? (Zones RGIE)","bathroom-cables-arei-zones",{"type":8,"value":9,"toc":406},"minimark",[10,15,28,32,39,104,117,120,124,239,244,276,280,350,354,361,374,378,381,385,400],[11,12,14],"h2",{"id":13},"le-xvb-est-toujours-autorisé-le-vob-sous-conditions","Le XVB est toujours autorisé — le VOB sous conditions",[16,17,18,19,23,24,27],"p",{},"L'installation électrique dans la salle de bain est soumise à des règles particulières en Belgique. La règle de base : le ",[20,21,22],"strong",{},"câble XVB"," (câble sous gaine) est autorisé dans toutes les zones de la salle de bain. Le ",[20,25,26],{},"fil VOB en conduit"," (Preflex) est soumis à des restrictions — notamment dans les cloisons creuses.",[11,29,31],{"id":30},"les-zones-rgie-de-la-salle-de-bain","Les zones RGIE de la salle de bain",[16,33,34,35,38],{},"Le RGIE définit ",[20,36,37],{},"trois zones"," autour de la baignoire et de la douche : zone 0, zone 1, zone 2 (uniquement pour les baignoires) et la zone hors périmètre (art. 7.1.3.2).",[40,41,42,58],"table",{},[43,44,45],"thead",{},[46,47,48,52,55],"tr",{},[49,50,51],"th",{},"Zone",[49,53,54],{},"Périmètre",[49,56,57],{},"Installation autorisée",[59,60,61,75,88],"tbody",{},[46,62,63,69,72],{},[64,65,66],"td",{},[20,67,68],{},"Zone 0",[64,70,71],{},"Intérieur de la baignoire\u002Fdouche",[64,73,74],{},"TBTS ≤ 12V uniquement, IPX7",[46,76,77,82,85],{},[64,78,79],{},[20,80,81],{},"Zone 1",[64,83,84],{},"Verticalement au-dessus de la zone 0, jusqu'à 2,25 m de hauteur",[64,86,87],{},"Appareils fixes ≥ IPX4 ; prises TBTS et interrupteurs TBTS autorisés (art. 7.1.5.2c n° 2 et 4)",[46,89,90,95,101],{},[64,91,92],{},[20,93,94],{},"Zone 2",[64,96,97,98],{},"60 cm autour de la zone 1 — ",[20,99,100],{},"uniquement pour les baignoires",[64,102,103],{},"Prises avec différentiel 30mA autorisées, appareils ≥ IPX4",[105,106,107],"blockquote",{},[16,108,109,112,113,116],{},[20,110,111],{},"Important :"," La zone 2 n'est ",[20,114,115],{},"pas définie"," pour les douches (art. 7.1.3.2 n° 3b). Pour les douches, la zone 1 est directement suivie de la zone hors périmètre.",[16,118,119],{},"En dehors de ces zones, les règles d'installation normales s'appliquent.",[11,121,123],{"id":122},"types-de-câbles-et-leur-admissibilité","Types de câbles et leur admissibilité",[40,125,126,145],{},[43,127,128],{},[46,129,130,133,136,138,140,142],{},[49,131,132],{},"Type de câble",[49,134,135],{},"Classe CPR",[49,137,68],{},[49,139,81],{},[49,141,94],{},[49,143,144],{},"Hors zones",[59,146,147,167,185,203,222],{},[46,148,149,154,157,160,163,165],{},[64,150,151],{},[20,152,153],{},"XVB 3G2,5",[64,155,156],{},"Cca",[64,158,159],{},"Non",[64,161,162],{},"Oui",[64,164,162],{},[64,166,162],{},[46,168,169,174,176,178,181,183],{},[64,170,171],{},[20,172,173],{},"XVB 3G1,5",[64,175,156],{},[64,177,159],{},[64,179,180],{},"Oui (éclairage)",[64,182,162],{},[64,184,162],{},[46,186,187,192,195,197,199,201],{},[64,188,189],{},[20,190,191],{},"VOB en Preflex gris",[64,193,194],{},"—",[64,196,159],{},[64,198,162],{},[64,200,162],{},[64,202,162],{},[46,204,205,210,212,214,217,220],{},[64,206,207],{},[20,208,209],{},"VOB en Preflex vert",[64,211,194],{},[64,213,159],{},[64,215,216],{},"Non (cloison creuse)",[64,218,219],{},"Restreint",[64,221,162],{},[46,223,224,229,231,233,235,237],{},[64,225,226],{},[20,227,228],{},"H07Z1-U (sans halogène)",[64,230,156],{},[64,232,159],{},[64,234,162],{},[64,236,162],{},[64,238,162],{},[240,241,243],"h3",{"id":242},"notes-importantes-sur-les-types-de-câbles","Notes importantes sur les types de câbles",[245,246,247,254,264,270],"ul",{},[248,249,250,253],"li",{},[20,251,252],{},"XVB"," (câble sous gaine) : Toujours le choix sûr. Adapté pour l'encastrement, le montage en saillie et les chemins de câbles.",[248,255,256,259,260,263],{},[20,257,258],{},"Preflex gris"," (conduit standard avec VOB pré-tiré) : Autorisé dans les murs massifs. ",[20,261,262],{},"Interdit"," dans les cloisons creuses et faux plafonds.",[248,265,266,269],{},[20,267,268],{},"Preflex Safe (vert)"," : Dans les murs massifs, le Preflex Safe (Cca) est autorisé même en zone 1. La restriction concerne les cloisons creuses (droogbouw), pas la zone elle-même.",[248,271,272,275],{},[20,273,274],{},"H07Z1-U"," : Fil sans halogène, particulièrement recommandé pour les zones sensibles. Note : le H07Z1-U en tant que fil individuel n'a pas de classe CPR Cca inhérente — la classe se réfère au système de câblage (fil + conduit). Le H07Z1-U en Preflex Safe atteint Cca.",[11,277,279],{"id":278},"tableau-des-sections","Tableau des sections",[40,281,282,295],{},[43,283,284],{},[46,285,286,289,292],{},[49,287,288],{},"Utilisation",[49,290,291],{},"Section min.",[49,293,294],{},"Disjoncteur",[59,296,297,308,319,329,339],{},[46,298,299,302,305],{},[64,300,301],{},"Éclairage",[64,303,304],{},"1,5 mm²",[64,306,307],{},"10A ou 16A",[46,309,310,313,316],{},[64,311,312],{},"Prises",[64,314,315],{},"2,5 mm²",[64,317,318],{},"16A ou 20A",[46,320,321,324,326],{},[64,322,323],{},"Lave-linge \u002F sèche-linge",[64,325,315],{},[64,327,328],{},"16A (circuit dédié)",[46,330,331,334,336],{},[64,332,333],{},"Chauffe-eau électrique (sous évier, ≤ 2 kW)",[64,335,315],{},[64,337,338],{},"16A",[46,340,341,344,347],{},[64,342,343],{},"Chauffe-eau instantané (18–27 kW)",[64,345,346],{},"6 mm² (32A) ou 10 mm² (40A, triphasé)",[64,348,349],{},"32A ou 40A",[11,351,353],{"id":352},"la-protection-différentielle-30ma-est-obligatoire","La protection différentielle 30mA est obligatoire",[16,355,356,357,360],{},"Selon l'article 7.1.4.3 du RGIE, ",[20,358,359],{},"tous les circuits de la salle de bain"," doivent être protégés par un différentiel 30mA — sans exception. Cela s'applique aussi bien à l'éclairage qu'aux prises et aux appareils fixes.",[105,362,363],{},[16,364,365,368,369,373],{},[20,366,367],{},"Attention"," : Même les circuits qui ne font que ",[370,371,372],"em",{},"traverser"," la salle de bain (par exemple, des câbles vers les combles) doivent respecter les exigences des zones s'ils passent à l'intérieur des zones de protection.",[11,375,377],{"id":376},"liaison-équipotentielle-dans-la-salle-de-bain","Liaison équipotentielle dans la salle de bain",[16,379,380],{},"Important : le RGIE (art. 7.1.4.4) exige une liaison équipotentielle supplémentaire dans la salle de bain — toutes les parties métalliques (conduites d'eau, radiateurs, baignoire, tuyaux d'évacuation) doivent être reliées entre elles et à la borne de terre principale par un conducteur de protection. L'absence de liaison équipotentielle est un motif fréquent de non-conformité lors du contrôle.",[11,382,384],{"id":383},"articles-connexes","Articles connexes",[245,386,387,394],{},[248,388,389],{},[390,391,393],"a",{"href":392},"\u002Ffr\u002Fblog\u002F30ma-ddr-par-prise","Ai-je besoin d'un différentiel 30mA par prise ?",[248,395,396],{},[390,397,399],{"href":398},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique — ce qu'il faut savoir",[16,401,402],{},[390,403,405],{"href":404},"\u002F","Planifiez l'électricité de votre salle de bain avec PlanElec — gratuit →",{"title":407,"searchDepth":408,"depth":408,"links":409},"",2,[410,411,412,416,417,418,419],{"id":13,"depth":408,"text":14},{"id":30,"depth":408,"text":31},{"id":122,"depth":408,"text":123,"children":413},[414],{"id":242,"depth":415,"text":243},3,{"id":278,"depth":408,"text":279},{"id":352,"depth":408,"text":353},{"id":376,"depth":408,"text":377},{"id":383,"depth":408,"text":384},"faq","2026-03-09","Le XVB est toujours autorisé, le VOB en conduit seulement sous conditions. Découvrez quels types de câbles sont autorisés dans chaque zone RGIE.","md","fr",{},true,"\u002Fblog\u002Fbathroom-cables-arei-zones.fr","4 min",12,{"title":5,"description":422},"cables-salle-de-bain-rgie","blog\u002Fbathroom-cables-arei-zones.fr",[434,435,436,437,252,438,439,440,441,442,443,444,445,446,447,448,449],"AREI","RGIE","salle de bain","zones","VOB","Preflex","câbles","différentiel","30mA","contrôle électrique","installation électrique","Belgique","schéma unifilaire","eendraadschema","plan de situation","CPR","L_MvtfaVoDtgPwSfXbPjyHTffaIarkqdwoW60DjH-8E",[452,857,1261,1562],{"id":453,"title":454,"articleId":6,"body":455,"category":420,"date":421,"description":838,"extension":423,"lastUpdated":421,"locale":839,"meta":840,"navigation":426,"path":841,"publishDate":421,"readTime":428,"refreshInterval":429,"seo":842,"slug":843,"stem":844,"tags":845,"__hash__":856},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.de.md","Welche Kabel darf ich im Badezimmer verwenden? (AREI Zonen)",{"type":8,"value":456,"toc":827},[457,461,472,476,483,541,553,556,560,671,675,703,707,774,778,785,797,801,804,808,822],[11,458,460],{"id":459},"xvb-ist-immer-erlaubt-vob-nur-eingeschränkt","XVB ist immer erlaubt — VOB nur eingeschränkt",[16,462,463,464,467,468,471],{},"Bei der Elektroinstallation im Badezimmer gelten in Belgien besondere Vorschriften. Die wichtigste Faustregel: ",[20,465,466],{},"XVB-Kabel"," (Mantelleitung) ist in allen Badezimmerzonen erlaubt. ",[20,469,470],{},"VOB-Draht in Leerrohr"," (Preflex) unterliegt Einschränkungen — insbesondere in Hohlwänden.",[11,473,475],{"id":474},"die-arei-badezimmerzonen","Die AREI-Badezimmerzonen",[16,477,478,479,482],{},"Das AREI definiert ",[20,480,481],{},"drei Bereiche"," rund um Badewanne und Dusche: Bereich 0, Bereich 1, Bereich 2 (nur bei Badewannen) und den Bereich außerhalb der Zonen (Art. 7.1.3.2).",[40,484,485,497],{},[43,486,487],{},[46,488,489,491,494],{},[49,490,51],{},[49,492,493],{},"Bereich",[49,495,496],{},"Erlaubte Installation",[59,498,499,512,525],{},[46,500,501,506,509],{},[64,502,503],{},[20,504,505],{},"Bereich 0",[64,507,508],{},"Inneres der Badewanne\u002FDusche",[64,510,511],{},"Nur SELV ≤ 12V, IPX7",[46,513,514,519,522],{},[64,515,516],{},[20,517,518],{},"Bereich 1",[64,520,521],{},"Senkrecht über Bereich 0, bis 2,25 m Höhe",[64,523,524],{},"Fest angeschlossene Geräte ≥ IPX4; SELV-Steckdosen und SELV-Schalter erlaubt (Art. 7.1.5.2c Nr. 2 und 4)",[46,526,527,532,538],{},[64,528,529],{},[20,530,531],{},"Bereich 2",[64,533,534,535],{},"60 cm um Bereich 1 herum — ",[20,536,537],{},"nur bei Badewannen",[64,539,540],{},"Steckdosen mit 30mA-FI erlaubt, Geräte ≥ IPX4",[105,542,543],{},[16,544,545,548,549,552],{},[20,546,547],{},"Wichtig:"," Bereich 2 ist für Duschen ",[20,550,551],{},"nicht festgelegt"," (Art. 7.1.3.2 Nr. 3b). Bei Duschen folgt auf Bereich 1 direkt der Bereich außerhalb der Zonen.",[16,554,555],{},"Außerhalb dieser Zonen gelten die normalen Installationsregeln.",[11,557,559],{"id":558},"kabeltypen-und-ihre-zulässigkeit","Kabeltypen und ihre Zulässigkeit",[40,561,562,581],{},[43,563,564],{},[46,565,566,569,572,574,576,578],{},[49,567,568],{},"Kabeltyp",[49,570,571],{},"CPR-Klasse",[49,573,68],{},[49,575,81],{},[49,577,94],{},[49,579,580],{},"Außerhalb",[59,582,583,601,618,635,654],{},[46,584,585,589,591,594,597,599],{},[64,586,587],{},[20,588,153],{},[64,590,156],{},[64,592,593],{},"Nein",[64,595,596],{},"Ja",[64,598,596],{},[64,600,596],{},[46,602,603,607,609,611,614,616],{},[64,604,605],{},[20,606,173],{},[64,608,156],{},[64,610,593],{},[64,612,613],{},"Ja (Beleuchtung)",[64,615,596],{},[64,617,596],{},[46,619,620,625,627,629,631,633],{},[64,621,622],{},[20,623,624],{},"VOB in Preflex grau",[64,626,194],{},[64,628,593],{},[64,630,596],{},[64,632,596],{},[64,634,596],{},[46,636,637,642,644,646,649,652],{},[64,638,639],{},[20,640,641],{},"VOB in Preflex grün",[64,643,194],{},[64,645,593],{},[64,647,648],{},"Nein (Hohlwand)",[64,650,651],{},"Eingeschränkt",[64,653,596],{},[46,655,656,661,663,665,667,669],{},[64,657,658],{},[20,659,660],{},"H07Z1-U (halogenfrei)",[64,662,156],{},[64,664,593],{},[64,666,596],{},[64,668,596],{},[64,670,596],{},[240,672,674],{"id":673},"wichtige-hinweise-zu-den-kabeltypen","Wichtige Hinweise zu den Kabeltypen",[245,676,677,682,692,698],{},[248,678,679,681],{},[20,680,252],{}," (Mantelleitung): Immer die sichere Wahl. Geeignet für Unterputz, Aufputz und in Kabelkanälen.",[248,683,684,687,688,691],{},[20,685,686],{},"Preflex grau"," (normales Leerrohr mit vorgezogenem VOB): Zulässig in Massivwänden. ",[20,689,690],{},"Nicht"," in Hohlwänden\u002FZwischendecken verwenden.",[248,693,694,697],{},[20,695,696],{},"Preflex Safe (grün)",": In Massivwänden ist Preflex Safe (Cca) auch in Zone 1 zulässig. Die Einschränkung betrifft Hohlwände (droogbouw), nicht die Zone selbst.",[248,699,700,702],{},[20,701,274],{},": Halogenfreier Draht, besonders für sensible Bereiche empfohlen. Hinweis: H07Z1-U als Einzeldraht hat keine inhärente CPR-Klasse Cca — die Klasse bezieht sich auf das Kabelsystem (Draht + Rohr). H07Z1-U in Preflex Safe erreicht Cca.",[11,704,706],{"id":705},"querschnitt-tabelle","Querschnitt-Tabelle",[40,708,709,722],{},[43,710,711],{},[46,712,713,716,719],{},[49,714,715],{},"Verwendung",[49,717,718],{},"Min. Querschnitt",[49,720,721],{},"Sicherung",[59,723,724,734,744,754,763],{},[46,725,726,729,731],{},[64,727,728],{},"Beleuchtung",[64,730,304],{},[64,732,733],{},"10A oder 16A",[46,735,736,739,741],{},[64,737,738],{},"Steckdosen",[64,740,315],{},[64,742,743],{},"16A oder 20A",[46,745,746,749,751],{},[64,747,748],{},"Waschmaschine\u002FTrockner",[64,750,315],{},[64,752,753],{},"16A (eigener Stromkreis)",[46,755,756,759,761],{},[64,757,758],{},"Elektrischer Boiler (Untertisch, ≤ 2 kW)",[64,760,315],{},[64,762,338],{},[46,764,765,768,771],{},[64,766,767],{},"Elektrischer Durchlauferhitzer (18–27 kW)",[64,769,770],{},"6 mm² (32A) oder 10 mm² (40A, Dreiphasen)",[64,772,773],{},"32A oder 40A",[11,775,777],{"id":776},"_30ma-differentialschutz-ist-pflicht","30mA-Differentialschutz ist Pflicht",[16,779,780,781,784],{},"Gemäß AREI Art. 7.1.4.3 müssen ",[20,782,783],{},"alle Stromkreise im Badezimmer"," durch einen 30mA-FI-Schutzschalter gesichert sein — ohne Ausnahme. Dies gilt für Beleuchtung, Steckdosen und fest angeschlossene Geräte gleichermaßen.",[105,786,787],{},[16,788,789,792,793,796],{},[20,790,791],{},"Achtung",": Auch Stromkreise, die nur ",[370,794,795],{},"durch"," das Badezimmer verlaufen (z.B. Kabel zum Dachboden), müssen den Zonenvorgaben entsprechen, wenn sie innerhalb der Schutzzonen verlegt werden.",[11,798,800],{"id":799},"potentialausgleich-im-badezimmer","Potentialausgleich im Badezimmer",[16,802,803],{},"Wichtig: Das AREI (Art. 7.1.4.4) verlangt einen zusätzlichen Potentialausgleich im Badezimmer — alle metallischen Teile (Wasserrohre, Heizkörper, Badewanne, Abflussrohre) müssen über einen Schutzleiter miteinander und mit der Haupterdungsschiene verbunden werden. Fehlender Potentialausgleich ist ein häufiger Mängelgrund bei der Keuring.",[11,805,807],{"id":806},"verwandte-artikel","Verwandte Artikel",[245,809,810,816],{},[248,811,812],{},[390,813,815],{"href":814},"\u002Fde\u002Fblog\u002F30ma-fi-pro-steckdose","Brauche ich einen 30mA FI-Schalter für jede Steckdose?",[248,817,818],{},[390,819,821],{"href":820},"\u002Fde\u002Fblog\u002Felektrische-abnahme","Elektrische Abnahme in Belgien — was Sie wissen müssen",[16,823,824],{},[390,825,826],{"href":404},"Planen Sie Ihre Badezimmer-Elektrik mit PlanElec — kostenlos →",{"title":407,"searchDepth":408,"depth":408,"links":828},[829,830,831,834,835,836,837],{"id":459,"depth":408,"text":460},{"id":474,"depth":408,"text":475},{"id":558,"depth":408,"text":559,"children":832},[833],{"id":673,"depth":415,"text":674},{"id":705,"depth":408,"text":706},{"id":776,"depth":408,"text":777},{"id":799,"depth":408,"text":800},{"id":806,"depth":408,"text":807},"XVB ist immer erlaubt, VOB in Leerrohr nur eingeschränkt. Erfahren Sie, welche Kabeltypen in welcher AREI-Zone zulässig sind und worauf Sie achten müssen.","de",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.de",{"title":454,"description":838},"badezimmer-kabel-arei-zonen","blog\u002Fbathroom-cables-arei-zones.de",[434,435,846,847,252,438,439,848,849,442,850,851,852,853,854,855,449],"Badezimmer","Zonen","Kabel","FI-Schutzschalter","Stromabnahme","Keuring","elektrische Installation","Belgien","Eindrahtschema","Situationsplan","u2AFNJg-k2r8mglgueyvhWHNcS5d15hMluMaeHzJQkE",{"id":858,"title":859,"articleId":6,"body":860,"category":420,"date":421,"description":1244,"extension":423,"lastUpdated":421,"locale":1245,"meta":1246,"navigation":426,"path":1247,"publishDate":421,"readTime":428,"refreshInterval":429,"seo":1248,"slug":6,"stem":1249,"tags":1250,"__hash__":1260},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.en.md","Which Cables Can I Use in the Bathroom? (AREI Zones)",{"type":8,"value":861,"toc":1233},[862,866,877,881,888,943,955,958,962,1075,1079,1107,1111,1180,1184,1191,1203,1207,1210,1214,1228],[11,863,865],{"id":864},"xvb-is-always-allowed-vob-only-with-restrictions","XVB is always allowed — VOB only with restrictions",[16,867,868,869,872,873,876],{},"Bathroom electrical installations in Belgium are subject to special regulations. The key rule of thumb: ",[20,870,871],{},"XVB cable"," (sheathed cable) is permitted in all bathroom zones. ",[20,874,875],{},"VOB wire in conduit"," (Preflex) has restrictions — especially in hollow walls.",[11,878,880],{"id":879},"the-arei-bathroom-zones","The AREI bathroom zones",[16,882,883,884,887],{},"The AREI defines ",[20,885,886],{},"three zones"," around bathtubs and showers: Zone 0, Zone 1, Zone 2 (bathtubs only), and the area outside the zones (Art. 7.1.3.2).",[40,889,890,902],{},[43,891,892],{},[46,893,894,896,899],{},[49,895,51],{},[49,897,898],{},"Area",[49,900,901],{},"Permitted installation",[59,903,904,916,928],{},[46,905,906,910,913],{},[64,907,908],{},[20,909,68],{},[64,911,912],{},"Inside the bathtub\u002Fshower",[64,914,915],{},"SELV ≤ 12V only, IPX7",[46,917,918,922,925],{},[64,919,920],{},[20,921,81],{},[64,923,924],{},"Vertically above Zone 0, up to 2.25 m height",[64,926,927],{},"Fixed appliances ≥ IPX4; SELV sockets and SELV switches permitted (Art. 7.1.5.2c Nr. 2 and 4)",[46,929,930,934,940],{},[64,931,932],{},[20,933,94],{},[64,935,936,937],{},"60 cm around Zone 1 — ",[20,938,939],{},"bathtubs only",[64,941,942],{},"Sockets with 30mA RCD allowed, appliances ≥ IPX4",[105,944,945],{},[16,946,947,950,951,954],{},[20,948,949],{},"Important:"," Zone 2 is ",[20,952,953],{},"not defined"," for showers (Art. 7.1.3.2 Nr. 3b). For showers, Zone 1 is followed directly by the area outside the zones.",[16,956,957],{},"Outside these zones, normal installation rules apply.",[11,959,961],{"id":960},"cable-types-and-their-permissibility","Cable types and their permissibility",[40,963,964,983],{},[43,965,966],{},[46,967,968,971,974,976,978,980],{},[49,969,970],{},"Cable type",[49,972,973],{},"CPR class",[49,975,68],{},[49,977,81],{},[49,979,94],{},[49,981,982],{},"Outside zones",[59,984,985,1004,1022,1039,1058],{},[46,986,987,992,994,997,1000,1002],{},[64,988,989],{},[20,990,991],{},"XVB 3G2.5",[64,993,156],{},[64,995,996],{},"No",[64,998,999],{},"Yes",[64,1001,999],{},[64,1003,999],{},[46,1005,1006,1011,1013,1015,1018,1020],{},[64,1007,1008],{},[20,1009,1010],{},"XVB 3G1.5",[64,1012,156],{},[64,1014,996],{},[64,1016,1017],{},"Yes (lighting)",[64,1019,999],{},[64,1021,999],{},[46,1023,1024,1029,1031,1033,1035,1037],{},[64,1025,1026],{},[20,1027,1028],{},"VOB in grey Preflex",[64,1030,194],{},[64,1032,996],{},[64,1034,999],{},[64,1036,999],{},[64,1038,999],{},[46,1040,1041,1046,1048,1050,1053,1056],{},[64,1042,1043],{},[20,1044,1045],{},"VOB in green Preflex",[64,1047,194],{},[64,1049,996],{},[64,1051,1052],{},"No (hollow wall)",[64,1054,1055],{},"Restricted",[64,1057,999],{},[46,1059,1060,1065,1067,1069,1071,1073],{},[64,1061,1062],{},[20,1063,1064],{},"H07Z1-U (halogen-free)",[64,1066,156],{},[64,1068,996],{},[64,1070,999],{},[64,1072,999],{},[64,1074,999],{},[240,1076,1078],{"id":1077},"important-notes-on-cable-types","Important notes on cable types",[245,1080,1081,1086,1096,1102],{},[248,1082,1083,1085],{},[20,1084,252],{}," (sheathed cable): Always the safe choice. Suitable for flush mounting, surface mounting, and cable trays.",[248,1087,1088,1091,1092,1095],{},[20,1089,1090],{},"Grey Preflex"," (standard conduit with pre-pulled VOB): Permitted in solid walls. ",[20,1093,1094],{},"Not"," allowed in hollow walls or suspended ceilings.",[248,1097,1098,1101],{},[20,1099,1100],{},"Preflex Safe (green)",": In solid walls, Preflex Safe (Cca) is also permitted in Zone 1. The restriction applies to hollow walls (droogbouw), not the zone itself.",[248,1103,1104,1106],{},[20,1105,274],{},": Halogen-free wire, particularly recommended for sensitive areas. Note: H07Z1-U as a single wire does not inherently have a CPR class of Cca — the class refers to the cable system (wire + conduit). H07Z1-U in Preflex Safe achieves Cca.",[11,1108,1110],{"id":1109},"cross-section-table","Cross-section table",[40,1112,1113,1126],{},[43,1114,1115],{},[46,1116,1117,1120,1123],{},[49,1118,1119],{},"Usage",[49,1121,1122],{},"Min. cross-section",[49,1124,1125],{},"Circuit breaker",[59,1127,1128,1139,1150,1160,1169],{},[46,1129,1130,1133,1136],{},[64,1131,1132],{},"Lighting",[64,1134,1135],{},"1.5 mm²",[64,1137,1138],{},"10A or 16A",[46,1140,1141,1144,1147],{},[64,1142,1143],{},"Sockets",[64,1145,1146],{},"2.5 mm²",[64,1148,1149],{},"16A or 20A",[46,1151,1152,1155,1157],{},[64,1153,1154],{},"Washing machine \u002F dryer",[64,1156,1146],{},[64,1158,1159],{},"16A (dedicated circuit)",[46,1161,1162,1165,1167],{},[64,1163,1164],{},"Electric water heater (under-sink, ≤ 2 kW)",[64,1166,1146],{},[64,1168,338],{},[46,1170,1171,1174,1177],{},[64,1172,1173],{},"Electric instantaneous water heater (18–27 kW)",[64,1175,1176],{},"6 mm² (32A) or 10 mm² (40A, three-phase)",[64,1178,1179],{},"32A or 40A",[11,1181,1183],{"id":1182},"_30ma-differential-protection-is-mandatory","30mA differential protection is mandatory",[16,1185,1186,1187,1190],{},"According to AREI Art. 7.1.4.3, ",[20,1188,1189],{},"all circuits in the bathroom"," must be protected by a 30mA RCD — no exceptions. This applies equally to lighting, sockets, and fixed appliances.",[105,1192,1193],{},[16,1194,1195,1198,1199,1202],{},[20,1196,1197],{},"Warning",": Even circuits that merely ",[370,1200,1201],{},"pass through"," the bathroom (e.g., cables to the attic) must comply with zone requirements if they run within the protection zones.",[11,1204,1206],{"id":1205},"equipotential-bonding-in-the-bathroom","Equipotential bonding in the bathroom",[16,1208,1209],{},"Important: The AREI (Art. 7.1.4.4) requires supplementary equipotential bonding in the bathroom — all metallic parts (water pipes, radiators, bathtub, drain pipes) must be connected to each other and to the main earthing terminal via a protective conductor. Missing equipotential bonding is a common reason for inspection failure.",[11,1211,1213],{"id":1212},"related-articles","Related articles",[245,1215,1216,1222],{},[248,1217,1218],{},[390,1219,1221],{"href":1220},"\u002Fen\u002Fblog\u002F30ma-rcd-per-socket","Do I need a 30mA RCD for every socket?",[248,1223,1224],{},[390,1225,1227],{"href":1226},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical inspection in Belgium — what you need to know",[16,1229,1230],{},[390,1231,1232],{"href":404},"Plan your bathroom electrics with PlanElec — free →",{"title":407,"searchDepth":408,"depth":408,"links":1234},[1235,1236,1237,1240,1241,1242,1243],{"id":864,"depth":408,"text":865},{"id":879,"depth":408,"text":880},{"id":960,"depth":408,"text":961,"children":1238},[1239],{"id":1077,"depth":415,"text":1078},{"id":1109,"depth":408,"text":1110},{"id":1182,"depth":408,"text":1183},{"id":1205,"depth":408,"text":1206},{"id":1212,"depth":408,"text":1213},"XVB is always permitted, VOB in conduit only with restrictions. Learn which cable types are allowed in each AREI zone and what to watch out for.","en",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.en",{"title":859,"description":1244},"blog\u002Fbathroom-cables-arei-zones.en",[434,435,1251,437,252,438,439,1252,1253,442,1254,1255,1256,1257,1258,447,854,446,1259,449],"bathroom","cables","RCD","inspection","keuring","electrical installation","Belgium","single-line diagram","situation plan","ZgbQLsxNNJRX4smfwHGocQCncIUqNvJMapcLmRmLIdU",{"id":4,"title":5,"articleId":6,"body":1262,"category":420,"date":421,"description":422,"extension":423,"lastUpdated":421,"locale":424,"meta":1559,"navigation":426,"path":427,"publishDate":421,"readTime":428,"refreshInterval":429,"seo":1560,"slug":431,"stem":432,"tags":1561,"__hash__":450},{"type":8,"value":1263,"toc":1548},[1264,1266,1272,1274,1278,1324,1332,1334,1336,1436,1438,1458,1460,1514,1516,1520,1528,1530,1532,1534,1544],[11,1265,14],{"id":13},[16,1267,18,1268,23,1270,27],{},[20,1269,22],{},[20,1271,26],{},[11,1273,31],{"id":30},[16,1275,34,1276,38],{},[20,1277,37],{},[40,1279,1280,1290],{},[43,1281,1282],{},[46,1283,1284,1286,1288],{},[49,1285,51],{},[49,1287,54],{},[49,1289,57],{},[59,1291,1292,1302,1312],{},[46,1293,1294,1298,1300],{},[64,1295,1296],{},[20,1297,68],{},[64,1299,71],{},[64,1301,74],{},[46,1303,1304,1308,1310],{},[64,1305,1306],{},[20,1307,81],{},[64,1309,84],{},[64,1311,87],{},[46,1313,1314,1318,1322],{},[64,1315,1316],{},[20,1317,94],{},[64,1319,97,1320],{},[20,1321,100],{},[64,1323,103],{},[105,1325,1326],{},[16,1327,1328,112,1330,116],{},[20,1329,111],{},[20,1331,115],{},[16,1333,119],{},[11,1335,123],{"id":122},[40,1337,1338,1354],{},[43,1339,1340],{},[46,1341,1342,1344,1346,1348,1350,1352],{},[49,1343,132],{},[49,1345,135],{},[49,1347,68],{},[49,1349,81],{},[49,1351,94],{},[49,1353,144],{},[59,1355,1356,1372,1388,1404,1420],{},[46,1357,1358,1362,1364,1366,1368,1370],{},[64,1359,1360],{},[20,1361,153],{},[64,1363,156],{},[64,1365,159],{},[64,1367,162],{},[64,1369,162],{},[64,1371,162],{},[46,1373,1374,1378,1380,1382,1384,1386],{},[64,1375,1376],{},[20,1377,173],{},[64,1379,156],{},[64,1381,159],{},[64,1383,180],{},[64,1385,162],{},[64,1387,162],{},[46,1389,1390,1394,1396,1398,1400,1402],{},[64,1391,1392],{},[20,1393,191],{},[64,1395,194],{},[64,1397,159],{},[64,1399,162],{},[64,1401,162],{},[64,1403,162],{},[46,1405,1406,1410,1412,1414,1416,1418],{},[64,1407,1408],{},[20,1409,209],{},[64,1411,194],{},[64,1413,159],{},[64,1415,216],{},[64,1417,219],{},[64,1419,162],{},[46,1421,1422,1426,1428,1430,1432,1434],{},[64,1423,1424],{},[20,1425,228],{},[64,1427,156],{},[64,1429,159],{},[64,1431,162],{},[64,1433,162],{},[64,1435,162],{},[240,1437,243],{"id":242},[245,1439,1440,1444,1450,1454],{},[248,1441,1442,253],{},[20,1443,252],{},[248,1445,1446,259,1448,263],{},[20,1447,258],{},[20,1449,262],{},[248,1451,1452,269],{},[20,1453,268],{},[248,1455,1456,275],{},[20,1457,274],{},[11,1459,279],{"id":278},[40,1461,1462,1472],{},[43,1463,1464],{},[46,1465,1466,1468,1470],{},[49,1467,288],{},[49,1469,291],{},[49,1471,294],{},[59,1473,1474,1482,1490,1498,1506],{},[46,1475,1476,1478,1480],{},[64,1477,301],{},[64,1479,304],{},[64,1481,307],{},[46,1483,1484,1486,1488],{},[64,1485,312],{},[64,1487,315],{},[64,1489,318],{},[46,1491,1492,1494,1496],{},[64,1493,323],{},[64,1495,315],{},[64,1497,328],{},[46,1499,1500,1502,1504],{},[64,1501,333],{},[64,1503,315],{},[64,1505,338],{},[46,1507,1508,1510,1512],{},[64,1509,343],{},[64,1511,346],{},[64,1513,349],{},[11,1515,353],{"id":352},[16,1517,356,1518,360],{},[20,1519,359],{},[105,1521,1522],{},[16,1523,1524,368,1526,373],{},[20,1525,367],{},[370,1527,372],{},[11,1529,377],{"id":376},[16,1531,380],{},[11,1533,384],{"id":383},[245,1535,1536,1540],{},[248,1537,1538],{},[390,1539,393],{"href":392},[248,1541,1542],{},[390,1543,399],{"href":398},[16,1545,1546],{},[390,1547,405],{"href":404},{"title":407,"searchDepth":408,"depth":408,"links":1549},[1550,1551,1552,1555,1556,1557,1558],{"id":13,"depth":408,"text":14},{"id":30,"depth":408,"text":31},{"id":122,"depth":408,"text":123,"children":1553},[1554],{"id":242,"depth":415,"text":243},{"id":278,"depth":408,"text":279},{"id":352,"depth":408,"text":353},{"id":376,"depth":408,"text":377},{"id":383,"depth":408,"text":384},{},{"title":5,"description":422},[434,435,436,437,252,438,439,440,441,442,443,444,445,446,447,448,449],{"id":1563,"title":1564,"articleId":6,"body":1565,"category":420,"date":421,"description":1944,"extension":423,"lastUpdated":421,"locale":1945,"meta":1946,"navigation":426,"path":1947,"publishDate":421,"readTime":428,"refreshInterval":429,"seo":1948,"slug":1949,"stem":1950,"tags":1951,"__hash__":1958},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.nl.md","Welke kabels mag ik gebruiken in de badkamer? (AREI-zones)",{"type":8,"value":1566,"toc":1933},[1567,1571,1582,1586,1593,1648,1660,1663,1667,1777,1781,1809,1813,1880,1884,1891,1903,1907,1910,1914,1928],[11,1568,1570],{"id":1569},"xvb-is-altijd-toegelaten-vob-alleen-onder-voorwaarden","XVB is altijd toegelaten — VOB alleen onder voorwaarden",[16,1572,1573,1574,1577,1578,1581],{},"Bij de elektrische installatie in de badkamer gelden in België bijzondere voorschriften. De belangrijkste vuistregel: ",[20,1575,1576],{},"XVB-kabel"," (mantelleiding) is in alle badkamerzones toegelaten. ",[20,1579,1580],{},"VOB-draad in buis"," (Preflex) is aan beperkingen onderworpen — vooral in holle wanden.",[11,1583,1585],{"id":1584},"de-arei-badkamerzones","De AREI-badkamerzones",[16,1587,1588,1589,1592],{},"Het AREI definieert ",[20,1590,1591],{},"drie zones"," rond bad en douche: Zone 0, Zone 1, Zone 2 (alleen bij badkuipen) en het gebied buiten de zones (Art. 7.1.3.2).",[40,1594,1595,1607],{},[43,1596,1597],{},[46,1598,1599,1601,1604],{},[49,1600,51],{},[49,1602,1603],{},"Gebied",[49,1605,1606],{},"Toegelaten installatie",[59,1608,1609,1621,1633],{},[46,1610,1611,1615,1618],{},[64,1612,1613],{},[20,1614,68],{},[64,1616,1617],{},"Binnenkant van het bad\u002Fde douche",[64,1619,1620],{},"Alleen ZLVS ≤ 12V, IPX7",[46,1622,1623,1627,1630],{},[64,1624,1625],{},[20,1626,81],{},[64,1628,1629],{},"Loodrecht boven zone 0, tot 2,25 m hoogte",[64,1631,1632],{},"Vast aangesloten toestellen ≥ IPX4; ZLVS-stopcontacten en ZLVS-schakelaars toegelaten (Art. 7.1.5.2c Nr. 2 en 4)",[46,1634,1635,1639,1645],{},[64,1636,1637],{},[20,1638,94],{},[64,1640,1641,1642],{},"60 cm rond zone 1 — ",[20,1643,1644],{},"alleen bij badkuipen",[64,1646,1647],{},"Stopcontacten met 30mA differentieel toegelaten, toestellen ≥ IPX4",[105,1649,1650],{},[16,1651,1652,1655,1656,1659],{},[20,1653,1654],{},"Belangrijk:"," Zone 2 is voor douches ",[20,1657,1658],{},"niet gedefinieerd"," (Art. 7.1.3.2 Nr. 3b). Bij douches volgt op zone 1 direct het gebied buiten de zones.",[16,1661,1662],{},"Buiten deze zones gelden de normale installatieregels.",[11,1664,1666],{"id":1665},"kabeltypes-en-hun-toelaatbaarheid","Kabeltypes en hun toelaatbaarheid",[40,1668,1669,1688],{},[43,1670,1671],{},[46,1672,1673,1676,1679,1681,1683,1685],{},[49,1674,1675],{},"Kabeltype",[49,1677,1678],{},"CPR-klasse",[49,1680,68],{},[49,1682,81],{},[49,1684,94],{},[49,1686,1687],{},"Buiten zones",[59,1689,1690,1707,1724,1741,1760],{},[46,1691,1692,1696,1698,1701,1703,1705],{},[64,1693,1694],{},[20,1695,153],{},[64,1697,156],{},[64,1699,1700],{},"Nee",[64,1702,596],{},[64,1704,596],{},[64,1706,596],{},[46,1708,1709,1713,1715,1717,1720,1722],{},[64,1710,1711],{},[20,1712,173],{},[64,1714,156],{},[64,1716,1700],{},[64,1718,1719],{},"Ja (verlichting)",[64,1721,596],{},[64,1723,596],{},[46,1725,1726,1731,1733,1735,1737,1739],{},[64,1727,1728],{},[20,1729,1730],{},"VOB in grijze Preflex",[64,1732,194],{},[64,1734,1700],{},[64,1736,596],{},[64,1738,596],{},[64,1740,596],{},[46,1742,1743,1748,1750,1752,1755,1758],{},[64,1744,1745],{},[20,1746,1747],{},"VOB in groene Preflex",[64,1749,194],{},[64,1751,1700],{},[64,1753,1754],{},"Nee (holle wand)",[64,1756,1757],{},"Beperkt",[64,1759,596],{},[46,1761,1762,1767,1769,1771,1773,1775],{},[64,1763,1764],{},[20,1765,1766],{},"H07Z1-U (halogeenvrij)",[64,1768,156],{},[64,1770,1700],{},[64,1772,596],{},[64,1774,596],{},[64,1776,596],{},[240,1778,1780],{"id":1779},"belangrijke-opmerkingen-bij-de-kabeltypes","Belangrijke opmerkingen bij de kabeltypes",[245,1782,1783,1788,1798,1804],{},[248,1784,1785,1787],{},[20,1786,252],{}," (mantelleiding): Altijd de veilige keuze. Geschikt voor inbouw, opbouw en in kabelgoten.",[248,1789,1790,1793,1794,1797],{},[20,1791,1792],{},"Grijze Preflex"," (standaard buis met voorgetrokken VOB): Toegelaten in massieve wanden. ",[20,1795,1796],{},"Niet"," in holle wanden of verlaagde plafonds.",[248,1799,1800,1803],{},[20,1801,1802],{},"Preflex Safe (groen)",": In massieve wanden is Preflex Safe (Cca) ook in zone 1 toegelaten. De beperking geldt voor holle wanden (droogbouw), niet voor de zone zelf.",[248,1805,1806,1808],{},[20,1807,274],{},": Halogeenvrije draad, vooral aanbevolen voor gevoelige zones. Let op: H07Z1-U als enkeldraad heeft geen inherente CPR-klasse Cca — de klasse verwijst naar het kabelsysteem (draad + buis). H07Z1-U in Preflex Safe bereikt Cca.",[11,1810,1812],{"id":1811},"doorsnede-tabel","Doorsnede-tabel",[40,1814,1815,1828],{},[43,1816,1817],{},[46,1818,1819,1822,1825],{},[49,1820,1821],{},"Gebruik",[49,1823,1824],{},"Min. doorsnede",[49,1826,1827],{},"Automaat",[59,1829,1830,1840,1850,1860,1869],{},[46,1831,1832,1835,1837],{},[64,1833,1834],{},"Verlichting",[64,1836,304],{},[64,1838,1839],{},"10A of 16A",[46,1841,1842,1845,1847],{},[64,1843,1844],{},"Stopcontacten",[64,1846,315],{},[64,1848,1849],{},"16A of 20A",[46,1851,1852,1855,1857],{},[64,1853,1854],{},"Wasmachine \u002F droogkast",[64,1856,315],{},[64,1858,1859],{},"16A (eigen kring)",[46,1861,1862,1865,1867],{},[64,1863,1864],{},"Elektrische boiler (onder aanrecht, ≤ 2 kW)",[64,1866,315],{},[64,1868,338],{},[46,1870,1871,1874,1877],{},[64,1872,1873],{},"Elektrische doorstromer (18–27 kW)",[64,1875,1876],{},"6 mm² (32A) of 10 mm² (40A, driefasig)",[64,1878,1879],{},"32A of 40A",[11,1881,1883],{"id":1882},"_30ma-differentieelbescherming-is-verplicht","30mA differentieelbescherming is verplicht",[16,1885,1886,1887,1890],{},"Volgens AREI Art. 7.1.4.3 moeten ",[20,1888,1889],{},"alle kringen in de badkamer"," beschermd zijn door een 30mA differentieel — zonder uitzondering. Dit geldt voor verlichting, stopcontacten en vast aangesloten toestellen.",[105,1892,1893],{},[16,1894,1895,1898,1899,1902],{},[20,1896,1897],{},"Let op",": Ook kringen die alleen maar ",[370,1900,1901],{},"door"," de badkamer lopen (bijv. kabels naar de zolder) moeten aan de zone-eisen voldoen als ze binnen de beschermingszones lopen.",[11,1904,1906],{"id":1905},"potentiaalvereffening-in-de-badkamer","Potentiaalvereffening in de badkamer",[16,1908,1909],{},"Belangrijk: Het AREI (Art. 7.1.4.4) vereist een bijkomende potentiaalvereffening in de badkamer — alle metalen delen (waterleidingen, radiatoren, badkuip, afvoerleidingen) moeten via een beschermingsleider onderling en met de hoofdaardingsklem verbonden worden. Ontbrekende potentiaalvereffening is een veelvoorkomende reden voor afkeuring bij de keuring.",[11,1911,1913],{"id":1912},"gerelateerde-artikelen","Gerelateerde artikelen",[245,1915,1916,1922],{},[248,1917,1918],{},[390,1919,1921],{"href":1920},"\u002Fblog\u002F30ma-aardlek-per-stopcontact","Heb ik een 30mA differentieel nodig per stopcontact?",[248,1923,1924],{},[390,1925,1927],{"href":1926},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België — wat u moet weten",[16,1929,1930],{},[390,1931,1932],{"href":404},"Plan uw badkamerelektriciteit met PlanElec — gratis →",{"title":407,"searchDepth":408,"depth":408,"links":1934},[1935,1936,1937,1940,1941,1942,1943],{"id":1569,"depth":408,"text":1570},{"id":1584,"depth":408,"text":1585},{"id":1665,"depth":408,"text":1666,"children":1938},[1939],{"id":1779,"depth":415,"text":1780},{"id":1811,"depth":408,"text":1812},{"id":1882,"depth":408,"text":1883},{"id":1905,"depth":408,"text":1906},{"id":1912,"depth":408,"text":1913},"XVB is altijd toegelaten, VOB in buis alleen onder voorwaarden. Ontdek welke kabeltypes zijn toegestaan in elke AREI-zone en waar u op moet letten.","nl",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.nl",{"title":1564,"description":1944},"badkamer-kabels-arei-zones","blog\u002Fbathroom-cables-arei-zones.nl",[434,435,1952,437,252,438,439,1953,1954,442,1255,1955,1956,447,1957,449],"badkamer","kabels","differentieel","elektrische installatie","België","situatieschema","FGPbM7vnU3id6vpaedLue-WoNAfOres3urO8n7x1Ta8",1775382368680]