[{"data":1,"prerenderedAt":4107},["ShallowReactive",2],{"blog-post-fr-dessiner-plan-situation-guide":3,"blog-alternates-draw-situation-plan":916},{"id":4,"title":5,"articleId":6,"body":7,"category":896,"date":897,"description":898,"extension":899,"lastUpdated":897,"locale":900,"meta":901,"navigation":775,"path":902,"publishDate":897,"readTime":903,"refreshInterval":904,"seo":905,"slug":906,"stem":907,"tags":908,"__hash__":915},"blog\u002Fblog\u002Fdraw-situation-plan.fr.md","Dessiner un plan de situation : Guide étape par étape selon le RGIE","draw-situation-plan",{"type":8,"value":9,"toc":874},"minimark",[10,14,23,41,44,47,52,57,60,65,90,94,97,207,209,213,224,403,411,413,417,420,424,457,461,481,485,505,509,512,536,540,560,562,566,573,578,590,595,609,626,628,632,635,661,663,667,758,760,764,832,834,838,859,861],[11,12,5],"h1",{"id":13},"dessiner-un-plan-de-situation-guide-étape-par-étape-selon-le-rgie",[15,16,17,18,22],"p",{},"Le plan de situation (aussi appelé schéma de position) montre ",[19,20,21],"strong",{},"où exactement"," chaque composant électrique se trouve dans votre bâtiment. Avec le schéma unifilaire, c'est l'un des deux documents obligatoires pour toute installation électrique en Belgique — sans lui, le contrôle par l'organisme agréé ne sera pas réussi.",[24,25,26],"blockquote",{},[15,27,28,31,32,36,37,40],{},[19,29,30],{},"En bref :"," Tandis que le schéma unifilaire représente le ",[33,34,35],"em",{},"raccordement logique"," (quel interrupteur commande quel luminaire, via quel circuit), le plan de situation montre la ",[33,38,39],{},"position physique"," de chaque composant sur le plan d'étage.",[15,42,43],{},"Dans ce guide, vous apprendrez comment créer un plan de situation conforme aux normes, étape par étape.",[45,46],"hr",{},[48,49,51],"h2",{"id":50},"étape-1-préparer-le-plan-détage","Étape 1 : Préparer le plan d'étage",[53,54,56],"h3",{"id":55},"dimensions-et-échelle","Dimensions et échelle",[15,58,59],{},"Le plan d'étage constitue la base de votre plan de situation. Vous pouvez le reprendre d'un plan de construction ou le dessiner vous-même.",[15,61,62],{},[19,63,64],{},"Important :",[66,67,68,76,83],"ul",{},[69,70,71,72,75],"li",{},"Utilisez une ",[19,73,74],{},"échelle uniforme"," (courante : 1:50 ou 1:100).",[69,77,78,79,82],{},"Dessinez tous les ",[19,80,81],{},"murs, portes et fenêtres",".",[69,84,85,86,89],{},"Marquez le ",[19,87,88],{},"sens d'ouverture"," des portes (quart de cercle) — cela influence la position des interrupteurs.",[53,91,93],{"id":92},"étiqueter-les-pièces","Étiqueter les pièces",[15,95,96],{},"Identifiez chaque pièce avec sa désignation et idéalement sa surface :",[98,99,100,116],"table",{},[101,102,103],"thead",{},[104,105,106,110,113],"tr",{},[107,108,109],"th",{},"Abréviation",[107,111,112],{},"Pièce",[107,114,115],{},"Surface typique",[117,118,119,131,142,153,164,175,186,197],"tbody",{},[104,120,121,125,128],{},[122,123,124],"td",{},"SÉJ",[122,126,127],{},"Séjour",[122,129,130],{},"25–40 m²",[104,132,133,136,139],{},[122,134,135],{},"CUI",[122,137,138],{},"Cuisine",[122,140,141],{},"10–20 m²",[104,143,144,147,150],{},[122,145,146],{},"CH",[122,148,149],{},"Chambre",[122,151,152],{},"12–18 m²",[104,154,155,158,161],{},[122,156,157],{},"SDB",[122,159,160],{},"Salle de bain",[122,162,163],{},"5–10 m²",[104,165,166,169,172],{},[122,167,168],{},"COU",[122,170,171],{},"Couloir",[122,173,174],{},"5–15 m²",[104,176,177,180,183],{},[122,178,179],{},"GAR",[122,181,182],{},"Garage",[122,184,185],{},"15–30 m²",[104,187,188,191,194],{},[122,189,190],{},"CAV",[122,192,193],{},"Cave",[122,195,196],{},"variable",[104,198,199,202,205],{},[122,200,201],{},"EXT",[122,203,204],{},"Extérieur",[122,206,196],{},[45,208],{},[48,210,212],{"id":211},"étape-2-utiliser-les-symboles-rgie","Étape 2 : Utiliser les symboles RGIE",[15,214,215,216,219,220,223],{},"Le RGIE prescrit dans le ",[19,217,218],{},"Tableau 2.23"," exactement quels symboles doivent être utilisés. Ceux-ci sont basés sur la norme ",[19,221,222],{},"IEC 60617",". Voici les 10 symboles les plus importants pour le plan de situation :",[98,225,226,242],{},[101,227,228],{},[104,229,230,233,236,239],{},[107,231,232],{},"N°",[107,234,235],{},"Symbole",[107,237,238],{},"Description",[107,240,241],{},"Utilisation",[117,243,244,260,275,291,307,323,339,355,371,387],{},[104,245,246,249,252,257],{},[122,247,248],{},"1",[122,250,251],{},"⏚ Demi-cercle",[122,253,254],{},[19,255,256],{},"Prise simple",[122,258,259],{},"Marquer position murale",[104,261,262,265,268,273],{},[122,263,264],{},"2",[122,266,267],{},"⏚⏚ Double demi-cercle",[122,269,270],{},[19,271,272],{},"Prise double",[122,274,259],{},[104,276,277,280,283,288],{},[122,278,279],{},"3",[122,281,282],{},"○ avec croix",[122,284,285],{},[19,286,287],{},"Plafonnier",[122,289,290],{},"Centre de la pièce\u002Fposition",[104,292,293,296,299,304],{},[122,294,295],{},"4",[122,297,298],{},"─○ avec trait",[122,300,301],{},[19,302,303],{},"Applique murale",[122,305,306],{},"Sur le mur",[104,308,309,312,315,320],{},[122,310,311],{},"5",[122,313,314],{},"Symbole interrupteur",[122,316,317],{},[19,318,319],{},"Interrupteur unipolaire",[122,321,322],{},"À côté de la porte (côté ouverture)",[104,324,325,328,331,336],{},[122,326,327],{},"6",[122,329,330],{},"Symbole interrupteur 2 flèches",[122,332,333],{},[19,334,335],{},"Interrupteur sériel",[122,337,338],{},"Commande 2 luminaires",[104,340,341,344,347,352],{},[122,342,343],{},"7",[122,345,346],{},"Symbole interrupteur avec ligne",[122,348,349],{},[19,350,351],{},"Interrupteur va-et-vient",[122,353,354],{},"Deux points, un luminaire",[104,356,357,360,363,368],{},[122,358,359],{},"8",[122,361,362],{},"Rectangle avec éclair",[122,364,365],{},[19,366,367],{},"Tableau de distribution",[122,369,370],{},"Généralement couloir\u002Flocal technique",[104,372,373,376,379,384],{},[122,374,375],{},"9",[122,377,378],{},"⏚ avec PE",[122,380,381],{},[19,382,383],{},"Prise de terre",[122,385,386],{},"Point de mise à la terre",[104,388,389,392,395,400],{},[122,390,391],{},"10",[122,393,394],{},"Cercle avec R",[122,396,397],{},[19,398,399],{},"Détecteur de fumée",[122,401,402],{},"Chaque chambre, couloir, cage d'escalier",[24,404,405],{},[15,406,407,410],{},[19,408,409],{},"Conseil :"," Utilisez exclusivement les symboles RGIE. Des symboles inventés seront refusés lors du contrôle.",[45,412],{},[48,414,416],{"id":415},"étape-3-dessiner-les-composants","Étape 3 : Dessiner les composants",[15,418,419],{},"Placez maintenant les symboles sur le plan d'étage. Les règles suivantes aident au positionnement correct :",[53,421,423],{"id":422},"prises-de-courant","Prises de courant",[66,425,426,433,439,445,451],{},[69,427,428,429,432],{},"Dessiner ",[19,430,431],{},"sur le mur",", à la position réelle.",[69,434,435,438],{},[19,436,437],{},"Cuisine :"," plan de travail minimum 4 prises, dont 2 au-dessus du plan de travail. Prises dédiées pour four, lave-vaisselle, réfrigérateur.",[69,440,441,444],{},[19,442,443],{},"Pièces de vie :"," Min. 1 prise par tranche de 4 m² entamée (recommandation pratique des associations d'installateurs — le RGIE ne prescrit pas de nombre minimum de prises par surface).",[69,446,447,450],{},[19,448,449],{},"Salle de bain :"," Prises basse tension à partir de la zone 2 (uniquement pour les baignoires, avec différentiel 30mA) ou hors zones. Pour les douches, la zone 2 n'existe pas (art. 7.1.3.2 n° 3b, art. 7.1.5.2d).",[69,452,453,456],{},[19,454,455],{},"Extérieur :"," Si une prise extérieure est installée, elle doit être protégée contre les intempéries (IP44) et sécurisée par son propre différentiel 30mA.",[53,458,460],{"id":459},"interrupteurs","Interrupteurs",[66,462,463,469,475],{},[69,464,465,468],{},[19,466,467],{},"À côté de la porte"," du côté de l'ouverture, à environ 105 cm de hauteur (recommandation pratique — le RGIE ne prescrit pas de hauteur spécifique pour les interrupteurs, mais exige qu'ils soient « facilement accessibles »).",[69,470,471,474],{},[19,472,473],{},"Interrupteurs va-et-vient"," pour les pièces à plusieurs entrées ou en début\u002Ffin d'escalier.",[69,476,477,478,82],{},"Reliez les interrupteurs et les luminaires associés par une ",[19,479,480],{},"ligne pointillée",[53,482,484],{"id":483},"points-lumineux","Points lumineux",[66,486,487,493,499],{},[69,488,489,492],{},[19,490,491],{},"Plafonniers"," au centre de la pièce ou à la position prévue.",[69,494,495,498],{},[19,496,497],{},"Appliques murales"," à la position sur le mur.",[69,500,501,502,82],{},"Chaque pièce nécessite au minimum ",[19,503,504],{},"un point lumineux",[53,506,508],{"id":507},"détecteurs-de-fumée","Détecteurs de fumée",[15,510,511],{},"Obligatoires selon la législation belge sur la sécurité incendie (varie selon la région) :",[66,513,514,521,527,533],{},[69,515,516,517,520],{},"En ",[19,518,519],{},"Flandre :"," Obligatoire dans les voies d'évacuation (couloirs, cages d'escalier) ; dans les chambres recommandé, mais pas obligatoire.",[69,522,516,523,526],{},[19,524,525],{},"Wallonie et Bruxelles"," : des réglementations propres s'appliquent.",[69,528,529,532],{},[19,530,531],{},"Couloirs et cages d'escalier"," — au minimum un détecteur de fumée par étage.",[69,534,535],{},"Dans la cuisine optionnel (détecteur de chaleur préféré pour éviter les fausses alarmes).",[53,537,539],{"id":538},"consommateurs-spéciaux","Consommateurs spéciaux",[66,541,542,548,554],{},[69,543,544,547],{},[19,545,546],{},"Borne de recharge"," (véhicule électrique) : garage ou mur extérieur, circuit dédié.",[69,549,550,553],{},[19,551,552],{},"Chauffe-eau\u002FBoiler :"," Circuit dédié, dessiner la position.",[69,555,556,559],{},[19,557,558],{},"Pompe à chaleur\u002FClimatisation :"," Marquer unité extérieure + unité intérieure.",[45,561],{},[48,563,565],{"id":564},"étape-4-attribuer-les-numéros-de-circuits","Étape 4 : Attribuer les numéros de circuits",[15,567,568,569,572],{},"Chaque composant du plan de situation reçoit le ",[19,570,571],{},"même numéro de circuit"," que dans le schéma unifilaire. C'est essentiel pour l'attribution lors du contrôle.",[15,574,575],{},[19,576,577],{},"Comment ça marche :",[579,580,581,584,587],"ol",{},[69,582,583],{},"Numérotez vos circuits dans le schéma unifilaire (1, 2, 3, ...).",[69,585,586],{},"Inscrivez le numéro à côté de chaque composant sur le plan de situation.",[69,588,589],{},"Utilisez une notation uniforme : par ex. « C1 » pour circuit 1 ou simplement « 1 ».",[15,591,592],{},[19,593,594],{},"Exemple :",[66,596,597,600,603,606],{},[69,598,599],{},"Circuit 1 : Éclairage rez-de-chaussée → Tous les luminaires du RDC reçoivent « 1 ».",[69,601,602],{},"Circuit 2 : Prises séjour → Toutes les prises du séjour reçoivent « 2 ».",[69,604,605],{},"Circuit 3 : Prises cuisine → Toutes les prises de cuisine reçoivent « 3 ».",[69,607,608],{},"Circuit 4 : Dédié four → Une prise avec « 4 ».",[24,610,611,620],{},[15,612,613,615,616,619],{},[19,614,64],{}," Les numéros doivent correspondre ",[19,617,618],{},"exactement"," entre le schéma unifilaire et le plan de situation. Les incohérences sont l'une des causes les plus fréquentes de remarques lors du contrôle.",[15,621,622,625],{},[19,623,624],{},"Obligation de documentation :"," Art. 9.1.2 n° 1 (schéma unifilaire) et art. 9.1.2 n° 2 (plan de situation).",[45,627],{},[48,629,631],{"id":630},"étape-5-légende-et-étiquetage","Étape 5 : Légende et étiquetage",[15,633,634],{},"Complétez votre plan avec :",[66,636,637,643,649,655],{},[69,638,639,642],{},[19,640,641],{},"Légende"," avec tous les symboles utilisés et leur signification.",[69,644,645,648],{},[19,646,647],{},"Cartouche"," avec : nom du propriétaire, adresse, date, auteur du plan, échelle.",[69,650,651,654],{},[19,652,653],{},"Flèche nord"," (optionnel, mais utile).",[69,656,657,660],{},[19,658,659],{},"Indication d'étage"," pour les bâtiments à plusieurs niveaux (un plan par étage).",[45,662],{},[48,664,666],{"id":665},"erreurs-fréquentes","Erreurs fréquentes",[98,668,669,682],{},[101,670,671],{},[104,672,673,676,679],{},[107,674,675],{},"Erreur",[107,677,678],{},"Conséquence",[107,680,681],{},"Solution",[117,683,684,695,706,717,727,738,748],{},[104,685,686,689,692],{},[122,687,688],{},"Détecteurs de fumée manquants",[122,690,691],{},"Contrôle non réussi",[122,693,694],{},"Min. 1 par étage dans les voies d'évacuation (varie selon la région)",[104,696,697,700,703],{},[122,698,699],{},"Prise extérieure non conforme",[122,701,702],{},"Remarque, si installée mais non conforme",[122,704,705],{},"Si installée : IP44, différentiel 30mA dédié. L'absence de prise extérieure n'est pas un motif de refus",[104,707,708,711,714],{},[122,709,710],{},"Étiquetage \u002F numéros de circuits manquants",[122,712,713],{},"Remarque",[122,715,716],{},"Numéroter chaque composant",[104,718,719,722,724],{},[122,720,721],{},"Mauvais symboles",[122,723,713],{},[122,725,726],{},"Utiliser uniquement le Tableau 2.23 du RGIE",[104,728,729,732,735],{},[122,730,731],{},"Interrupteur du mauvais côté de la porte",[122,733,734],{},"Non pratique (pas d'infraction RGIE)",[122,736,737],{},"Vérifier le sens d'ouverture",[104,739,740,743,745],{},[122,741,742],{},"Prise salle de bain en zone 0 ou 1",[122,744,691],{},[122,746,747],{},"Prises à partir de la zone 2 (baignoire uniquement) ou hors zones (douche) (art. 7.1.5.2c\u002Fd)",[104,749,750,753,755],{},[122,751,752],{},"Pas de légende",[122,754,713],{},[122,756,757],{},"Joindre un tableau de symboles",[45,759],{},[48,761,763],{"id":762},"checklist-avant-soumission","Checklist avant soumission",[66,765,768,778,784,790,796,802,808,814,820,826],{"className":766},[767],"contains-task-list",[69,769,772,777],{"className":770},[771],"task-list-item",[773,774],"input",{"disabled":775,"type":776},true,"checkbox"," Toutes les pièces étiquetées",[69,779,781,783],{"className":780},[771],[773,782],{"disabled":775,"type":776}," Toutes les prises, interrupteurs, luminaires dessinés",[69,785,787,789],{"className":786},[771],[773,788],{"disabled":775,"type":776}," Détecteurs de fumée dans les voies d'évacuation (min. 1 par étage, varie selon la région)",[69,791,793,795],{"className":792},[771],[773,794],{"disabled":775,"type":776}," Prises extérieures, si installées, conformes (IP44, différentiel 30mA dédié)",[69,797,799,801],{"className":798},[771],[773,800],{"disabled":775,"type":776}," Numéros de circuits sur chaque composant",[69,803,805,807],{"className":804},[771],[773,806],{"disabled":775,"type":776}," Les numéros correspondent au schéma unifilaire",[69,809,811,813],{"className":810},[771],[773,812],{"disabled":775,"type":776}," Symboles RGIE utilisés (Tableau 2.23)",[69,815,817,819],{"className":816},[771],[773,818],{"disabled":775,"type":776}," Légende présente",[69,821,823,825],{"className":822},[771],[773,824],{"disabled":775,"type":776}," Cartouche avec nom, adresse, date",[69,827,829,831],{"className":828},[771],[773,830],{"disabled":775,"type":776}," Un plan par étage",[45,833],{},[48,835,837],{"id":836},"articles-connexes","Articles connexes",[66,839,840,847,853],{},[69,841,842],{},[843,844,846],"a",{"href":845},"\u002Ffr\u002Fblog\u002Fquest-ce-quun-schema-unifilaire","Qu'est-ce qu'un schéma unifilaire ?",[69,848,849],{},[843,850,852],{"href":851},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","Contrôle électrique en Belgique",[69,854,855],{},[843,856,858],{"href":857},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique : Conception et dimensionnement",[45,860],{},[15,862,863],{},[33,864,865,866,869,870],{},"Avec ",[19,867,868],{},"PlanElec",", créez votre plan de situation directement à partir du plan d'étage — dessinez les pièces, placez les appareils par glisser-déposer, les symboles RGIE sont utilisés automatiquement. ",[843,871,873],{"href":872},"\u002F","Essayer gratuitement →",{"title":875,"searchDepth":876,"depth":876,"links":877},"",2,[878,883,884,891,892,893,894,895],{"id":50,"depth":876,"text":51,"children":879},[880,882],{"id":55,"depth":881,"text":56},3,{"id":92,"depth":881,"text":93},{"id":211,"depth":876,"text":212},{"id":415,"depth":876,"text":416,"children":885},[886,887,888,889,890],{"id":422,"depth":881,"text":423},{"id":459,"depth":881,"text":460},{"id":483,"depth":881,"text":484},{"id":507,"depth":881,"text":508},{"id":538,"depth":881,"text":539},{"id":564,"depth":876,"text":565},{"id":630,"depth":876,"text":631},{"id":665,"depth":876,"text":666},{"id":762,"depth":876,"text":763},{"id":836,"depth":876,"text":837},"guide","2026-03-30","Guide complet pour créer un plan de situation conforme au RGIE. De la préparation du plan d'étage aux symboles RGIE jusqu'au dessin finalisé.","md","fr",{},"\u002Fblog\u002Fdraw-situation-plan.fr","8 min",12,{"title":5,"description":898},"dessiner-plan-situation-guide","blog\u002Fdraw-situation-plan.fr",[909,910,911,896,912,913,914],"plan de situation","RGIE","symboles","dessin","plan électrique","plan d'étage","Wpc9xEfZ3BkiZ-yjisU3MCnVQpz9GYOIyWWdtvj0PRA",[917,1774,2626,3256],{"id":918,"title":919,"articleId":6,"body":920,"category":896,"date":897,"description":1758,"extension":899,"lastUpdated":897,"locale":1759,"meta":1760,"navigation":775,"path":1761,"publishDate":897,"readTime":903,"refreshInterval":904,"seo":1762,"slug":1763,"stem":1764,"tags":1765,"__hash__":1773},"blog\u002Fblog\u002Fdraw-situation-plan.de.md","Situationsplan zeichnen: Schritt-für-Schritt-Anleitung nach AREI",{"type":8,"value":921,"toc":1739},[922,925,932,948,951,953,957,961,964,969,992,996,999,1096,1098,1102,1112,1281,1289,1291,1295,1298,1302,1333,1337,1356,1360,1380,1383,1386,1410,1414,1434,1436,1440,1447,1452,1463,1468,1482,1499,1501,1505,1508,1534,1536,1540,1631,1633,1637,1700,1702,1706,1726,1728],[11,923,919],{"id":924},"situationsplan-zeichnen-schritt-für-schritt-anleitung-nach-arei",[15,926,927,928,931],{},"Der Situationsplan (auch Lageplan oder Plan de Situation) zeigt, ",[19,929,930],{},"wo genau"," sich jede elektrische Komponente in Ihrem Gebäude befindet. Zusammen mit dem Eindrahtschema ist er eines der beiden Pflichtdokumente für jede Elektroinstallation in Belgien — ohne ihn besteht die Abnahme durch den zugelassenen Kontrollorganismus nicht.",[24,933,934],{},[15,935,936,939,940,943,944,947],{},[19,937,938],{},"Kurz erklärt:"," Während das Eindrahtschema die ",[33,941,942],{},"logische Verschaltung"," darstellt (welcher Schalter steuert welche Leuchte, über welchen Stromkreis), zeigt der Situationsplan die ",[33,945,946],{},"physische Position"," jeder Komponente im Grundriss.",[15,949,950],{},"In dieser Anleitung lernen Sie, wie Sie einen normgerechten Situationsplan Schritt für Schritt erstellen.",[45,952],{},[48,954,956],{"id":955},"schritt-1-grundriss-vorbereiten","Schritt 1: Grundriss vorbereiten",[53,958,960],{"id":959},"maße-und-maßstab","Maße und Maßstab",[15,962,963],{},"Der Grundriss bildet die Basis Ihres Situationsplans. Sie können ihn aus einem Bauplan übernehmen oder selbst zeichnen.",[15,965,966],{},[19,967,968],{},"Wichtig:",[66,970,971,978,985],{},[69,972,973,974,977],{},"Verwenden Sie einen ",[19,975,976],{},"einheitlichen Maßstab"," (üblich: 1:50 oder 1:100).",[69,979,980,981,984],{},"Zeichnen Sie alle ",[19,982,983],{},"Wände, Türen und Fenster"," ein.",[69,986,987,988,991],{},"Markieren Sie ",[19,989,990],{},"Öffnungsrichtungen"," von Türen (Viertelkreis) — das beeinflusst die Schalterposition.",[53,993,995],{"id":994},"räume-beschriften","Räume beschriften",[15,997,998],{},"Versehen Sie jeden Raum mit seiner Bezeichnung und idealerweise der Fläche:",[98,1000,1001,1014],{},[101,1002,1003],{},[104,1004,1005,1008,1011],{},[107,1006,1007],{},"Kürzel",[107,1009,1010],{},"Raum",[107,1012,1013],{},"Typische Fläche",[117,1015,1016,1026,1036,1046,1056,1066,1075,1086],{},[104,1017,1018,1021,1024],{},[122,1019,1020],{},"WZ",[122,1022,1023],{},"Wohnzimmer",[122,1025,130],{},[104,1027,1028,1031,1034],{},[122,1029,1030],{},"KÜ",[122,1032,1033],{},"Küche",[122,1035,141],{},[104,1037,1038,1041,1044],{},[122,1039,1040],{},"SZ",[122,1042,1043],{},"Schlafzimmer",[122,1045,152],{},[104,1047,1048,1051,1054],{},[122,1049,1050],{},"BZ",[122,1052,1053],{},"Badezimmer",[122,1055,163],{},[104,1057,1058,1061,1064],{},[122,1059,1060],{},"FL",[122,1062,1063],{},"Flur",[122,1065,174],{},[104,1067,1068,1071,1073],{},[122,1069,1070],{},"GA",[122,1072,182],{},[122,1074,185],{},[104,1076,1077,1080,1083],{},[122,1078,1079],{},"KE",[122,1081,1082],{},"Keller",[122,1084,1085],{},"variabel",[104,1087,1088,1091,1094],{},[122,1089,1090],{},"AU",[122,1092,1093],{},"Außenbereich",[122,1095,1085],{},[45,1097],{},[48,1099,1101],{"id":1100},"schritt-2-arei-symbole-verwenden","Schritt 2: AREI-Symbole verwenden",[15,1103,1104,1105,1108,1109,1111],{},"Das AREI schreibt in ",[19,1106,1107],{},"Tabelle 2.23"," genau vor, welche Symbole verwendet werden müssen. Diese basieren auf der Norm ",[19,1110,222],{},". Hier die 10 wichtigsten Symbole für den Situationsplan:",[98,1113,1114,1130],{},[101,1115,1116],{},[104,1117,1118,1121,1124,1127],{},[107,1119,1120],{},"Nr.",[107,1122,1123],{},"Symbol",[107,1125,1126],{},"Beschreibung",[107,1128,1129],{},"Verwendung",[117,1131,1132,1147,1161,1176,1191,1206,1221,1236,1251,1266],{},[104,1133,1134,1136,1139,1144],{},[122,1135,248],{},[122,1137,1138],{},"⏚ Halbkreis",[122,1140,1141],{},[19,1142,1143],{},"Einfache Steckdose",[122,1145,1146],{},"Wandposition markieren",[104,1148,1149,1151,1154,1159],{},[122,1150,264],{},[122,1152,1153],{},"⏚⏚ Doppel-Halbkreis",[122,1155,1156],{},[19,1157,1158],{},"Doppelsteckdose",[122,1160,1146],{},[104,1162,1163,1165,1168,1173],{},[122,1164,279],{},[122,1166,1167],{},"○ mit Kreuz",[122,1169,1170],{},[19,1171,1172],{},"Deckenleuchte",[122,1174,1175],{},"Mitte des Raums\u002FPosition",[104,1177,1178,1180,1183,1188],{},[122,1179,295],{},[122,1181,1182],{},"─○ mit Strich",[122,1184,1185],{},[19,1186,1187],{},"Wandleuchte",[122,1189,1190],{},"An der Wand",[104,1192,1193,1195,1198,1203],{},[122,1194,311],{},[122,1196,1197],{},"Schaltzeichen",[122,1199,1200],{},[19,1201,1202],{},"Einfacher Schalter",[122,1204,1205],{},"Neben der Tür (Öffnungsseite)",[104,1207,1208,1210,1213,1218],{},[122,1209,327],{},[122,1211,1212],{},"Schaltzeichen mit 2 Pfeilen",[122,1214,1215],{},[19,1216,1217],{},"Serienschalter",[122,1219,1220],{},"Steuert 2 Leuchten",[104,1222,1223,1225,1228,1233],{},[122,1224,343],{},[122,1226,1227],{},"Schaltzeichen mit Linie",[122,1229,1230],{},[19,1231,1232],{},"Wechselschalter",[122,1234,1235],{},"Zwei Stellen, ein Licht",[104,1237,1238,1240,1243,1248],{},[122,1239,359],{},[122,1241,1242],{},"Rechteck mit Blitz",[122,1244,1245],{},[19,1246,1247],{},"Verteilerkasten",[122,1249,1250],{},"Meist Flur\u002FTechnikraum",[104,1252,1253,1255,1258,1263],{},[122,1254,375],{},[122,1256,1257],{},"⏚ mit PE",[122,1259,1260],{},[19,1261,1262],{},"Erdungsanschluss",[122,1264,1265],{},"Erdungspunkt",[104,1267,1268,1270,1273,1278],{},[122,1269,391],{},[122,1271,1272],{},"Kreis mit R",[122,1274,1275],{},[19,1276,1277],{},"Rauchmelder",[122,1279,1280],{},"Fluchtwege (Flur, Treppenhaus), regional unterschiedlich",[24,1282,1283],{},[15,1284,1285,1288],{},[19,1286,1287],{},"Tipp:"," Verwenden Sie ausschließlich die AREI-Symbole. Eigene Fantasie-Symbole werden bei der Kontrolle beanstandet.",[45,1290],{},[48,1292,1294],{"id":1293},"schritt-3-komponenten-einzeichnen","Schritt 3: Komponenten einzeichnen",[15,1296,1297],{},"Jetzt platzieren Sie die Symbole im Grundriss. Folgende Regeln helfen bei der korrekten Positionierung:",[53,1299,1301],{"id":1300},"steckdosen","Steckdosen",[66,1303,1304,1309,1315,1321,1327],{},[69,1305,1306,1308],{},[19,1307,1190],{}," einzeichnen, an der tatsächlichen Position.",[69,1310,1311,1314],{},[19,1312,1313],{},"Küche:"," Arbeitsfläche mind. 4 Steckdosen, davon 2 über der Arbeitsplatte. Dedizierte Steckdosen für Backofen, Geschirrspüler, Kühlschrank.",[69,1316,1317,1320],{},[19,1318,1319],{},"Wohnräume:"," Mind. 1 Steckdose pro angefangene 4 m² (Praxisempfehlung der Installateurverbände — das AREI schreibt keine Mindestanzahl von Steckdosen pro Fläche vor).",[69,1322,1323,1326],{},[19,1324,1325],{},"Badezimmer:"," Niederspannungs-Steckdosen erst ab Bereich 2 (nur bei Badewannen, mit 30mA-FI) bzw. außerhalb der Bereiche. Bei Duschen existiert Bereich 2 nicht (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[69,1328,1329,1332],{},[19,1330,1331],{},"Außen:"," Falls Außensteckdose vorhanden, muss sie wettergeschützt (IP44) und mit eigenem 30-mA-FI-Schutz abgesichert sein.",[53,1334,1336],{"id":1335},"schalter","Schalter",[66,1338,1339,1345,1350],{},[69,1340,1341,1344],{},[19,1342,1343],{},"Neben der Tür"," auf der Öffnungsseite, ca. 105 cm Höhe (Praxisempfehlung -- das AREI schreibt keine spezifische Schalthöhe vor, fordert aber 'leicht zugänglich').",[69,1346,1347,1349],{},[19,1348,1232],{}," bei Räumen mit mehreren Eingängen oder am Treppenanfang\u002F-ende.",[69,1351,1352,1353,82],{},"Verbinden Sie Schalter und zugehörige Leuchten mit einer ",[19,1354,1355],{},"gestrichelten Linie",[53,1357,1359],{"id":1358},"leuchten","Leuchten",[66,1361,1362,1368,1374],{},[69,1363,1364,1367],{},[19,1365,1366],{},"Deckenleuchten"," in die Raummitte oder an die geplante Position.",[69,1369,1370,1373],{},[19,1371,1372],{},"Wandleuchten"," an der Wandposition.",[69,1375,1376,1377,82],{},"Jeder Raum braucht mindestens ",[19,1378,1379],{},"einen Lichtpunkt",[53,1381,1277],{"id":1382},"rauchmelder",[15,1384,1385],{},"Seit dem belgischen Brandschutzgesetz Pflicht (regional unterschiedlich):",[66,1387,1388,1395,1401,1407],{},[69,1389,1390,1391,1394],{},"In ",[19,1392,1393],{},"Flandern:"," Pflicht in Fluchtwegen (Flure, Treppenhäuser); in Schlafzimmern empfohlen, aber nicht vorgeschrieben.",[69,1396,1390,1397,1400],{},[19,1398,1399],{},"Wallonien und Brüssel"," gelten eigene Regelungen.",[69,1402,1403,1406],{},[19,1404,1405],{},"Flure und Treppenhäuser"," — mindestens ein Rauchmelder pro Etage.",[69,1408,1409],{},"In der Küche optional (Hitzemelder bevorzugt wegen Fehlalarmen).",[53,1411,1413],{"id":1412},"sonderverbraucher","Sonderverbraucher",[66,1415,1416,1422,1428],{},[69,1417,1418,1421],{},[19,1419,1420],{},"Wallbox"," (Elektroauto): Garage oder Außenwand, eigener Stromkreis.",[69,1423,1424,1427],{},[19,1425,1426],{},"Boiler\u002FDurchlauferhitzer:"," Eigener Stromkreis, Position einzeichnen.",[69,1429,1430,1433],{},[19,1431,1432],{},"Wärmepumpe\u002FKlimaanlage:"," Außeneinheit + Inneneinheit markieren.",[45,1435],{},[48,1437,1439],{"id":1438},"schritt-4-stromkreisnummern-zuordnen","Schritt 4: Stromkreisnummern zuordnen",[15,1441,1442,1443,1446],{},"Jede Komponente im Situationsplan erhält die ",[19,1444,1445],{},"gleiche Stromkreisnummer"," wie im Eindrahtschema. Das ist essentiell für die Zuordnung bei der Kontrolle.",[15,1448,1449],{},[19,1450,1451],{},"So funktioniert es:",[579,1453,1454,1457,1460],{},[69,1455,1456],{},"Nummerieren Sie Ihre Stromkreise im Eindrahtschema durch (1, 2, 3, ...).",[69,1458,1459],{},"Schreiben Sie die Nummer an jede Komponente im Situationsplan.",[69,1461,1462],{},"Verwenden Sie einheitliche Notation: z. B. „K1\" für Stromkreis 1 oder einfach „1\".",[15,1464,1465],{},[19,1466,1467],{},"Beispiel:",[66,1469,1470,1473,1476,1479],{},[69,1471,1472],{},"Stromkreis 1: Beleuchtung Erdgeschoss → Alle Leuchten im EG erhalten „1\".",[69,1474,1475],{},"Stromkreis 2: Steckdosen Wohnzimmer → Alle WZ-Steckdosen erhalten „2\".",[69,1477,1478],{},"Stromkreis 3: Steckdosen Küche → Alle KÜ-Steckdosen erhalten „3\".",[69,1480,1481],{},"Stromkreis 4: Dediziert Backofen → Eine Steckdose mit „4\".",[24,1483,1484,1493],{},[15,1485,1486,1488,1489,1492],{},[19,1487,968],{}," Die Nummern müssen zwischen Eindrahtschema und Situationsplan ",[19,1490,1491],{},"exakt übereinstimmen",". Inkonsistenzen sind einer der häufigsten Gründe für eine Beanstandung bei der Kontrolle.",[15,1494,1495,1498],{},[19,1496,1497],{},"Dokumentationspflicht:"," Art. 9.1.2 Nr. 1 (Einstrich-Schema) und Art. 9.1.2 Nr. 2 (Lageplan\u002FSituationsplan).",[45,1500],{},[48,1502,1504],{"id":1503},"schritt-5-legende-und-beschriftung","Schritt 5: Legende und Beschriftung",[15,1506,1507],{},"Ergänzen Sie Ihren Plan um:",[66,1509,1510,1516,1522,1528],{},[69,1511,1512,1515],{},[19,1513,1514],{},"Legende"," mit allen verwendeten Symbolen und ihrer Bedeutung.",[69,1517,1518,1521],{},[19,1519,1520],{},"Titelblock"," (Cartouche) mit: Name des Eigentümers, Adresse, Datum, Planersteller, Maßstab.",[69,1523,1524,1527],{},[19,1525,1526],{},"Nordpfeil"," (optional, aber hilfreich).",[69,1529,1530,1533],{},[19,1531,1532],{},"Stockwerk-Kennzeichnung"," bei mehrgeschossigen Gebäuden (ein Plan pro Etage).",[45,1535],{},[48,1537,1539],{"id":1538},"häufige-fehler","Häufige Fehler",[98,1541,1542,1555],{},[101,1543,1544],{},[104,1545,1546,1549,1552],{},[107,1547,1548],{},"Fehler",[107,1550,1551],{},"Konsequenz",[107,1553,1554],{},"Lösung",[117,1556,1557,1568,1579,1590,1600,1611,1621],{},[104,1558,1559,1562,1565],{},[122,1560,1561],{},"Fehlende Rauchmelder",[122,1563,1564],{},"Kontrolle nicht bestanden",[122,1566,1567],{},"Mind. 1 pro Etage in Fluchtwegen (regional unterschiedlich)",[104,1569,1570,1573,1576],{},[122,1571,1572],{},"Außensteckdose nicht normgerecht",[122,1574,1575],{},"Beanstandung, falls vorhanden aber nicht konform",[122,1577,1578],{},"Wenn installiert: IP44, eigener 30-mA-FI-Schutz. Eine fehlende Außensteckdose ist kein Durchfallgrund",[104,1580,1581,1584,1587],{},[122,1582,1583],{},"Fehlende Beschriftung \u002F Stromkreisnummern",[122,1585,1586],{},"Beanstandung",[122,1588,1589],{},"Jede Komponente nummerieren",[104,1591,1592,1595,1597],{},[122,1593,1594],{},"Falsche Symbole",[122,1596,1586],{},[122,1598,1599],{},"Nur AREI-Tabelle 2.23 verwenden",[104,1601,1602,1605,1608],{},[122,1603,1604],{},"Schalter auf falscher Türseite",[122,1606,1607],{},"Unpraktisch (kein AREI-Verstoß)",[122,1609,1610],{},"Öffnungsrichtung prüfen",[104,1612,1613,1616,1618],{},[122,1614,1615],{},"Badezimmer-Steckdose in Bereich 0 oder 1",[122,1617,1564],{},[122,1619,1620],{},"Steckdosen erst ab Bereich 2 (nur Badewanne) bzw. außerhalb der Bereiche (Dusche) erlaubt (Art. 7.1.5.2c\u002Fd)",[104,1622,1623,1626,1628],{},[122,1624,1625],{},"Keine Legende",[122,1627,1586],{},[122,1629,1630],{},"Symboltabelle beifügen",[45,1632],{},[48,1634,1636],{"id":1635},"checkliste-vor-der-abgabe","Checkliste vor der Abgabe",[66,1638,1640,1646,1652,1658,1664,1670,1676,1682,1688,1694],{"className":1639},[767],[69,1641,1643,1645],{"className":1642},[771],[773,1644],{"disabled":775,"type":776}," Alle Räume beschriftet",[69,1647,1649,1651],{"className":1648},[771],[773,1650],{"disabled":775,"type":776}," Alle Steckdosen, Schalter, Leuchten eingezeichnet",[69,1653,1655,1657],{"className":1654},[771],[773,1656],{"disabled":775,"type":776}," Rauchmelder in Fluchtwegen (mind. 1 pro Etage, regional unterschiedlich)",[69,1659,1661,1663],{"className":1660},[771],[773,1662],{"disabled":775,"type":776}," Außensteckdosen, falls vorhanden, normgerecht (IP44, eigener 30-mA-FI)",[69,1665,1667,1669],{"className":1666},[771],[773,1668],{"disabled":775,"type":776}," Stromkreisnummern an jeder Komponente",[69,1671,1673,1675],{"className":1672},[771],[773,1674],{"disabled":775,"type":776}," Nummern stimmen mit Eindrahtschema überein",[69,1677,1679,1681],{"className":1678},[771],[773,1680],{"disabled":775,"type":776}," AREI-Symbole verwendet (Tabelle 2.23)",[69,1683,1685,1687],{"className":1684},[771],[773,1686],{"disabled":775,"type":776}," Legende vorhanden",[69,1689,1691,1693],{"className":1690},[771],[773,1692],{"disabled":775,"type":776}," Titelblock mit Name, Adresse, Datum",[69,1695,1697,1699],{"className":1696},[771],[773,1698],{"disabled":775,"type":776}," Ein Plan pro Stockwerk",[45,1701],{},[48,1703,1705],{"id":1704},"verwandte-artikel","Verwandte Artikel",[66,1707,1708,1714,1720],{},[69,1709,1710],{},[843,1711,1713],{"href":1712},"\u002Fde\u002Fblog\u002Fwas-ist-eindrahtschema","Was ist ein Eindrahtschema?",[69,1715,1716],{},[843,1717,1719],{"href":1718},"\u002Fde\u002Fblog\u002Felektrische-kontrolle","Elektrische Kontrolle in Belgien",[69,1721,1722],{},[843,1723,1725],{"href":1724},"\u002Fde\u002Fblog\u002Fschaltschrank-planen-aufbau","Schaltschrank planen: Aufbau und Dimensionierung",[45,1727],{},[15,1729,1730],{},[33,1731,1732,1733,1735,1736],{},"Mit ",[19,1734,868],{}," erstellen Sie Ihren Situationsplan direkt aus dem Grundriss — Räume zeichnen, Geräte per Drag & Drop platzieren, AREI-Symbole werden automatisch verwendet. ",[843,1737,1738],{"href":872},"Jetzt kostenlos testen →",{"title":875,"searchDepth":876,"depth":876,"links":1740},[1741,1745,1746,1753,1754,1755,1756,1757],{"id":955,"depth":876,"text":956,"children":1742},[1743,1744],{"id":959,"depth":881,"text":960},{"id":994,"depth":881,"text":995},{"id":1100,"depth":876,"text":1101},{"id":1293,"depth":876,"text":1294,"children":1747},[1748,1749,1750,1751,1752],{"id":1300,"depth":881,"text":1301},{"id":1335,"depth":881,"text":1336},{"id":1358,"depth":881,"text":1359},{"id":1382,"depth":881,"text":1277},{"id":1412,"depth":881,"text":1413},{"id":1438,"depth":876,"text":1439},{"id":1503,"depth":876,"text":1504},{"id":1538,"depth":876,"text":1539},{"id":1635,"depth":876,"text":1636},{"id":1704,"depth":876,"text":1705},"Komplette Anleitung zum Erstellen eines AREI-konformen Situationsplans. Von der Grundrissvorbereitung über AREI-Symbole bis zur fertigen Zeichnung.","de",{},"\u002Fblog\u002Fdraw-situation-plan.de",{"title":919,"description":1758},"situationsplan-zeichnen-anleitung","blog\u002Fdraw-situation-plan.de",[1766,1767,1768,1769,1770,1771,1772],"situationsplan","AREI","symbole","anleitung","zeichnen","elektroplan","grundriss","DfLf16mvq0YknMfgWTjjQOz_URm7F2-1t3686ckWq7E",{"id":1775,"title":1776,"articleId":6,"body":1777,"category":896,"date":897,"description":2612,"extension":899,"lastUpdated":897,"locale":2613,"meta":2614,"navigation":775,"path":2615,"publishDate":897,"readTime":903,"refreshInterval":904,"seo":2616,"slug":2617,"stem":2618,"tags":2619,"__hash__":2625},"blog\u002Fblog\u002Fdraw-situation-plan.en.md","Draw a Situation Plan: Step-by-Step Guide According to AREI\u002FRGIE",{"type":8,"value":1778,"toc":2593},[1779,1782,1789,1805,1808,1810,1814,1818,1821,1826,1848,1852,1855,1950,1952,1956,1966,2133,2141,2143,2147,2150,2154,2187,2191,2211,2215,2235,2239,2242,2265,2269,2289,2291,2295,2302,2307,2318,2323,2337,2354,2356,2360,2363,2389,2391,2395,2485,2487,2491,2554,2556,2560,2580,2582],[11,1780,1776],{"id":1781},"draw-a-situation-plan-step-by-step-guide-according-to-areirgie",[15,1783,1784,1785,1788],{},"The situation plan (also called position plan or plan de situation) shows ",[19,1786,1787],{},"where exactly"," each electrical component is located in your building. Together with the single-line diagram, it is one of the two mandatory documents for every electrical installation in Belgium — without it, the inspection by the approved control body will not pass.",[24,1790,1791],{},[15,1792,1793,1796,1797,1800,1801,1804],{},[19,1794,1795],{},"In brief:"," While the single-line diagram shows the ",[33,1798,1799],{},"logical wiring"," (which switch controls which light, via which circuit), the situation plan shows the ",[33,1802,1803],{},"physical position"," of each component on the floor plan.",[15,1806,1807],{},"In this guide, you will learn how to create a standards-compliant situation plan step by step.",[45,1809],{},[48,1811,1813],{"id":1812},"step-1-prepare-the-floor-plan","Step 1: Prepare the Floor Plan",[53,1815,1817],{"id":1816},"dimensions-and-scale","Dimensions and Scale",[15,1819,1820],{},"The floor plan forms the basis of your situation plan. You can take it from a construction plan or draw it yourself.",[15,1822,1823],{},[19,1824,1825],{},"Important:",[66,1827,1828,1835,1841],{},[69,1829,1830,1831,1834],{},"Use a ",[19,1832,1833],{},"uniform scale"," (common: 1:50 or 1:100).",[69,1836,1837,1838,82],{},"Draw all ",[19,1839,1840],{},"walls, doors, and windows",[69,1842,1843,1844,1847],{},"Mark the ",[19,1845,1846],{},"opening direction"," of doors (quarter circle) — this affects switch placement.",[53,1849,1851],{"id":1850},"label-the-rooms","Label the Rooms",[15,1853,1854],{},"Give each room its designation and ideally its area:",[98,1856,1857,1870],{},[101,1858,1859],{},[104,1860,1861,1864,1867],{},[107,1862,1863],{},"Abbreviation",[107,1865,1866],{},"Room",[107,1868,1869],{},"Typical Area",[117,1871,1872,1882,1892,1902,1912,1922,1930,1940],{},[104,1873,1874,1877,1880],{},[122,1875,1876],{},"LR",[122,1878,1879],{},"Living Room",[122,1881,130],{},[104,1883,1884,1887,1890],{},[122,1885,1886],{},"KI",[122,1888,1889],{},"Kitchen",[122,1891,141],{},[104,1893,1894,1897,1900],{},[122,1895,1896],{},"BR",[122,1898,1899],{},"Bedroom",[122,1901,152],{},[104,1903,1904,1907,1910],{},[122,1905,1906],{},"BA",[122,1908,1909],{},"Bathroom",[122,1911,163],{},[104,1913,1914,1917,1920],{},[122,1915,1916],{},"HA",[122,1918,1919],{},"Hallway",[122,1921,174],{},[104,1923,1924,1926,1928],{},[122,1925,1070],{},[122,1927,182],{},[122,1929,185],{},[104,1931,1932,1935,1938],{},[122,1933,1934],{},"BS",[122,1936,1937],{},"Basement",[122,1939,196],{},[104,1941,1942,1945,1948],{},[122,1943,1944],{},"EX",[122,1946,1947],{},"Exterior",[122,1949,196],{},[45,1951],{},[48,1953,1955],{"id":1954},"step-2-use-areirgie-symbols","Step 2: Use AREI\u002FRGIE Symbols",[15,1957,1958,1959,1962,1963,1965],{},"The AREI prescribes in ",[19,1960,1961],{},"Table 2.23"," exactly which symbols must be used. These are based on the ",[19,1964,222],{}," standard. Here are the 10 most important symbols for the situation plan:",[98,1967,1968,1982],{},[101,1969,1970],{},[104,1971,1972,1975,1977,1979],{},[107,1973,1974],{},"No.",[107,1976,1123],{},[107,1978,238],{},[107,1980,1981],{},"Usage",[117,1983,1984,1999,2013,2028,2043,2058,2073,2088,2103,2118],{},[104,1985,1986,1988,1991,1996],{},[122,1987,248],{},[122,1989,1990],{},"⏚ Semicircle",[122,1992,1993],{},[19,1994,1995],{},"Single socket outlet",[122,1997,1998],{},"Mark wall position",[104,2000,2001,2003,2006,2011],{},[122,2002,264],{},[122,2004,2005],{},"⏚⏚ Double semicircle",[122,2007,2008],{},[19,2009,2010],{},"Double socket outlet",[122,2012,1998],{},[104,2014,2015,2017,2020,2025],{},[122,2016,279],{},[122,2018,2019],{},"○ with cross",[122,2021,2022],{},[19,2023,2024],{},"Ceiling light",[122,2026,2027],{},"Centre of room\u002Fposition",[104,2029,2030,2032,2035,2040],{},[122,2031,295],{},[122,2033,2034],{},"─○ with line",[122,2036,2037],{},[19,2038,2039],{},"Wall light",[122,2041,2042],{},"On the wall",[104,2044,2045,2047,2050,2055],{},[122,2046,311],{},[122,2048,2049],{},"Switch symbol",[122,2051,2052],{},[19,2053,2054],{},"Single-pole switch",[122,2056,2057],{},"Next to door (opening side)",[104,2059,2060,2062,2065,2070],{},[122,2061,327],{},[122,2063,2064],{},"Switch symbol with 2 arrows",[122,2066,2067],{},[19,2068,2069],{},"Series switch",[122,2071,2072],{},"Controls 2 luminaires",[104,2074,2075,2077,2080,2085],{},[122,2076,343],{},[122,2078,2079],{},"Switch symbol with line",[122,2081,2082],{},[19,2083,2084],{},"Two-way switch",[122,2086,2087],{},"Two locations, one light",[104,2089,2090,2092,2095,2100],{},[122,2091,359],{},[122,2093,2094],{},"Rectangle with lightning",[122,2096,2097],{},[19,2098,2099],{},"Distribution board",[122,2101,2102],{},"Usually hallway\u002Futility room",[104,2104,2105,2107,2110,2115],{},[122,2106,375],{},[122,2108,2109],{},"⏚ with PE",[122,2111,2112],{},[19,2113,2114],{},"Earth connection",[122,2116,2117],{},"Earthing point",[104,2119,2120,2122,2125,2130],{},[122,2121,391],{},[122,2123,2124],{},"Circle with R",[122,2126,2127],{},[19,2128,2129],{},"Smoke detector",[122,2131,2132],{},"Escape routes (hallway, staircase), regionally varies",[24,2134,2135],{},[15,2136,2137,2140],{},[19,2138,2139],{},"Tip:"," Use only the AREI\u002FRGIE symbols. Self-invented symbols will be rejected during inspection.",[45,2142],{},[48,2144,2146],{"id":2145},"step-3-draw-the-components","Step 3: Draw the Components",[15,2148,2149],{},"Now place the symbols on the floor plan. The following rules help with correct positioning:",[53,2151,2153],{"id":2152},"socket-outlets","Socket Outlets",[66,2155,2156,2163,2169,2175,2181],{},[69,2157,2158,2159,2162],{},"Draw ",[19,2160,2161],{},"on the wall"," at the actual position.",[69,2164,2165,2168],{},[19,2166,2167],{},"Kitchen:"," worktop at least 4 sockets, of which 2 above the counter. Dedicated sockets for oven, dishwasher, refrigerator.",[69,2170,2171,2174],{},[19,2172,2173],{},"Living spaces:"," At least 1 socket per started 4 m² (practical recommendation by installer associations — the AREI does not prescribe a minimum number of sockets per area).",[69,2176,2177,2180],{},[19,2178,2179],{},"Bathroom:"," Low-voltage sockets only from Zone 2 (bathtubs only, with 30mA RCD) or outside the zones. For showers, Zone 2 does not exist (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[69,2182,2183,2186],{},[19,2184,2185],{},"Outdoor:"," If an outdoor socket is installed, it must be weatherproof (IP44) and protected by a dedicated 30mA RCD.",[53,2188,2190],{"id":2189},"switches","Switches",[66,2192,2193,2199,2205],{},[69,2194,2195,2198],{},[19,2196,2197],{},"Next to the door"," on the opening side, approximately 105 cm height (practical recommendation — the AREI does not prescribe a specific switch height, but requires 'easily accessible').",[69,2200,2201,2204],{},[19,2202,2203],{},"Two-way switches"," for rooms with multiple entrances or at the top\u002Fbottom of stairs.",[69,2206,2207,2208,82],{},"Connect switches and associated luminaires with a ",[19,2209,2210],{},"dashed line",[53,2212,2214],{"id":2213},"lighting-points","Lighting Points",[66,2216,2217,2223,2229],{},[69,2218,2219,2222],{},[19,2220,2221],{},"Ceiling lights"," in the centre of the room or at the planned position.",[69,2224,2225,2228],{},[19,2226,2227],{},"Wall lights"," at the wall position.",[69,2230,2231,2232,82],{},"Every room needs at least ",[19,2233,2234],{},"one lighting point",[53,2236,2238],{"id":2237},"smoke-detectors","Smoke Detectors",[15,2240,2241],{},"Mandatory under Belgian fire safety legislation (varies by region):",[66,2243,2244,2250,2256,2262],{},[69,2245,1390,2246,2249],{},[19,2247,2248],{},"Flanders:"," Mandatory in escape routes (hallways, staircases); recommended but not required in bedrooms.",[69,2251,1390,2252,2255],{},[19,2253,2254],{},"Wallonia and Brussels",", separate regulations apply.",[69,2257,2258,2261],{},[19,2259,2260],{},"Hallways and staircases"," — at least one smoke detector per floor.",[69,2263,2264],{},"In the kitchen optional (heat detector preferred to avoid false alarms).",[53,2266,2268],{"id":2267},"special-consumers","Special Consumers",[66,2270,2271,2277,2283],{},[69,2272,2273,2276],{},[19,2274,2275],{},"EV charger"," (electric vehicle): garage or exterior wall, dedicated circuit.",[69,2278,2279,2282],{},[19,2280,2281],{},"Water heater\u002FBoiler:"," Dedicated circuit, mark the position.",[69,2284,2285,2288],{},[19,2286,2287],{},"Heat pump\u002FAir conditioning:"," Mark outdoor unit + indoor unit.",[45,2290],{},[48,2292,2294],{"id":2293},"step-4-assign-circuit-numbers","Step 4: Assign Circuit Numbers",[15,2296,2297,2298,2301],{},"Each component on the situation plan receives the ",[19,2299,2300],{},"same circuit number"," as in the single-line diagram. This is essential for identification during inspection.",[15,2303,2304],{},[19,2305,2306],{},"How it works:",[579,2308,2309,2312,2315],{},[69,2310,2311],{},"Number your circuits in the single-line diagram (1, 2, 3, ...).",[69,2313,2314],{},"Write the number next to each component on the situation plan.",[69,2316,2317],{},"Use consistent notation: e.g., \"C1\" for circuit 1 or simply \"1\".",[15,2319,2320],{},[19,2321,2322],{},"Example:",[66,2324,2325,2328,2331,2334],{},[69,2326,2327],{},"Circuit 1: Ground floor lighting → All ground floor luminaires get \"1\".",[69,2329,2330],{},"Circuit 2: Living room sockets → All living room sockets get \"2\".",[69,2332,2333],{},"Circuit 3: Kitchen sockets → All kitchen sockets get \"3\".",[69,2335,2336],{},"Circuit 4: Dedicated oven → One socket with \"4\".",[24,2338,2339,2348],{},[15,2340,2341,2343,2344,2347],{},[19,2342,1825],{}," The numbers must match ",[19,2345,2346],{},"exactly"," between the single-line diagram and the situation plan. Inconsistencies are one of the most common reasons for remarks during inspection.",[15,2349,2350,2353],{},[19,2351,2352],{},"Documentation requirement:"," Art. 9.1.2 Nr. 1 (single-line diagram) and Art. 9.1.2 Nr. 2 (situation plan).",[45,2355],{},[48,2357,2359],{"id":2358},"step-5-legend-and-labelling","Step 5: Legend and Labelling",[15,2361,2362],{},"Complete your plan with:",[66,2364,2365,2371,2377,2383],{},[69,2366,2367,2370],{},[19,2368,2369],{},"Legend"," with all symbols used and their meaning.",[69,2372,2373,2376],{},[19,2374,2375],{},"Title block"," (cartouche) with: owner's name, address, date, plan creator, scale.",[69,2378,2379,2382],{},[19,2380,2381],{},"North arrow"," (optional, but helpful).",[69,2384,2385,2388],{},[19,2386,2387],{},"Floor indication"," for multi-storey buildings (one plan per floor).",[45,2390],{},[48,2392,2394],{"id":2393},"common-mistakes","Common Mistakes",[98,2396,2397,2409],{},[101,2398,2399],{},[104,2400,2401,2404,2407],{},[107,2402,2403],{},"Mistake",[107,2405,2406],{},"Consequence",[107,2408,681],{},[117,2410,2411,2422,2433,2444,2454,2465,2475],{},[104,2412,2413,2416,2419],{},[122,2414,2415],{},"Missing smoke detectors",[122,2417,2418],{},"Inspection failed",[122,2420,2421],{},"Min. 1 per floor in escape routes (varies by region)",[104,2423,2424,2427,2430],{},[122,2425,2426],{},"Outdoor socket not compliant",[122,2428,2429],{},"Remark, if present but non-compliant",[122,2431,2432],{},"If installed: IP44, dedicated 30mA RCD. A missing outdoor socket is not a fail reason",[104,2434,2435,2438,2441],{},[122,2436,2437],{},"Missing labels \u002F circuit numbers",[122,2439,2440],{},"Remark",[122,2442,2443],{},"Number every component",[104,2445,2446,2449,2451],{},[122,2447,2448],{},"Wrong symbols",[122,2450,2440],{},[122,2452,2453],{},"Use only AREI Table 2.23",[104,2455,2456,2459,2462],{},[122,2457,2458],{},"Switch on wrong side of door",[122,2460,2461],{},"Impractical (not an AREI violation)",[122,2463,2464],{},"Check opening direction",[104,2466,2467,2470,2472],{},[122,2468,2469],{},"Bathroom socket in Zone 0 or 1",[122,2471,2418],{},[122,2473,2474],{},"Sockets only from Zone 2 (bathtub) or outside the zones (shower) (Art. 7.1.5.2c\u002Fd)",[104,2476,2477,2480,2482],{},[122,2478,2479],{},"No legend",[122,2481,2440],{},[122,2483,2484],{},"Include symbol table",[45,2486],{},[48,2488,2490],{"id":2489},"checklist-before-submission","Checklist Before Submission",[66,2492,2494,2500,2506,2512,2518,2524,2530,2536,2542,2548],{"className":2493},[767],[69,2495,2497,2499],{"className":2496},[771],[773,2498],{"disabled":775,"type":776}," All rooms labelled",[69,2501,2503,2505],{"className":2502},[771],[773,2504],{"disabled":775,"type":776}," All sockets, switches, lighting points drawn",[69,2507,2509,2511],{"className":2508},[771],[773,2510],{"disabled":775,"type":776}," Smoke detectors in escape routes (min. 1 per floor, varies by region)",[69,2513,2515,2517],{"className":2514},[771],[773,2516],{"disabled":775,"type":776}," Outdoor sockets, if installed, compliant (IP44, dedicated 30mA RCD)",[69,2519,2521,2523],{"className":2520},[771],[773,2522],{"disabled":775,"type":776}," Circuit numbers on every component",[69,2525,2527,2529],{"className":2526},[771],[773,2528],{"disabled":775,"type":776}," Numbers match the single-line diagram",[69,2531,2533,2535],{"className":2532},[771],[773,2534],{"disabled":775,"type":776}," AREI symbols used (Table 2.23)",[69,2537,2539,2541],{"className":2538},[771],[773,2540],{"disabled":775,"type":776}," Legend present",[69,2543,2545,2547],{"className":2544},[771],[773,2546],{"disabled":775,"type":776}," Title block with name, address, date",[69,2549,2551,2553],{"className":2550},[771],[773,2552],{"disabled":775,"type":776}," One plan per floor",[45,2555],{},[48,2557,2559],{"id":2558},"related-articles","Related Articles",[66,2561,2562,2568,2574],{},[69,2563,2564],{},[843,2565,2567],{"href":2566},"\u002Fen\u002Fblog\u002Fwhat-is-single-line-diagram","What Is a Single-Line Diagram?",[69,2569,2570],{},[843,2571,2573],{"href":2572},"\u002Fen\u002Fblog\u002Felectrical-inspection","Electrical Inspection in Belgium",[69,2575,2576],{},[843,2577,2579],{"href":2578},"\u002Fen\u002Fblog\u002Fdistribution-board-planning-guide","Distribution Board Planning: Layout and Sizing",[45,2581],{},[15,2583,2584],{},[33,2585,2586,2587,2589,2590],{},"With ",[19,2588,868],{},", create your situation plan directly from the floor plan — draw rooms, drag and drop devices, AREI symbols are used automatically. ",[843,2591,2592],{"href":872},"Try for free →",{"title":875,"searchDepth":876,"depth":876,"links":2594},[2595,2599,2600,2607,2608,2609,2610,2611],{"id":1812,"depth":876,"text":1813,"children":2596},[2597,2598],{"id":1816,"depth":881,"text":1817},{"id":1850,"depth":881,"text":1851},{"id":1954,"depth":876,"text":1955},{"id":2145,"depth":876,"text":2146,"children":2601},[2602,2603,2604,2605,2606],{"id":2152,"depth":881,"text":2153},{"id":2189,"depth":881,"text":2190},{"id":2213,"depth":881,"text":2214},{"id":2237,"depth":881,"text":2238},{"id":2267,"depth":881,"text":2268},{"id":2293,"depth":876,"text":2294},{"id":2358,"depth":876,"text":2359},{"id":2393,"depth":876,"text":2394},{"id":2489,"depth":876,"text":2490},{"id":2558,"depth":876,"text":2559},"Complete guide to creating an AREI\u002FRGIE-compliant situation plan. From floor plan preparation to AREI symbols to the finished drawing.","en",{},"\u002Fblog\u002Fdraw-situation-plan.en",{"title":1776,"description":2612},"draw-situation-plan-guide","blog\u002Fdraw-situation-plan.en",[2620,1767,2621,896,2622,2623,2624],"situation plan","symbols","drawing","electrical plan","floor plan","OnIT3y4v8bkN1c21nJzgibxhZsBL8fX__6YUoqGuORc",{"id":4,"title":5,"articleId":6,"body":2627,"category":896,"date":897,"description":898,"extension":899,"lastUpdated":897,"locale":900,"meta":3253,"navigation":775,"path":902,"publishDate":897,"readTime":903,"refreshInterval":904,"seo":3254,"slug":906,"stem":907,"tags":3255,"__hash__":915},{"type":8,"value":2628,"toc":3234},[2629,2631,2635,2645,2647,2649,2651,2653,2655,2659,2673,2675,2677,2755,2757,2759,2765,2901,2907,2909,2911,2913,2915,2937,2939,2953,2955,2969,2971,2973,2989,2991,3005,3007,3009,3013,3017,3025,3029,3039,3051,3053,3055,3057,3075,3077,3079,3149,3151,3153,3206,3208,3210,3224,3226],[11,2630,5],{"id":13},[15,2632,17,2633,22],{},[19,2634,21],{},[24,2636,2637],{},[15,2638,2639,31,2641,36,2643,40],{},[19,2640,30],{},[33,2642,35],{},[33,2644,39],{},[15,2646,43],{},[45,2648],{},[48,2650,51],{"id":50},[53,2652,56],{"id":55},[15,2654,59],{},[15,2656,2657],{},[19,2658,64],{},[66,2660,2661,2665,2669],{},[69,2662,71,2663,75],{},[19,2664,74],{},[69,2666,78,2667,82],{},[19,2668,81],{},[69,2670,85,2671,89],{},[19,2672,88],{},[53,2674,93],{"id":92},[15,2676,96],{},[98,2678,2679,2689],{},[101,2680,2681],{},[104,2682,2683,2685,2687],{},[107,2684,109],{},[107,2686,112],{},[107,2688,115],{},[117,2690,2691,2699,2707,2715,2723,2731,2739,2747],{},[104,2692,2693,2695,2697],{},[122,2694,124],{},[122,2696,127],{},[122,2698,130],{},[104,2700,2701,2703,2705],{},[122,2702,135],{},[122,2704,138],{},[122,2706,141],{},[104,2708,2709,2711,2713],{},[122,2710,146],{},[122,2712,149],{},[122,2714,152],{},[104,2716,2717,2719,2721],{},[122,2718,157],{},[122,2720,160],{},[122,2722,163],{},[104,2724,2725,2727,2729],{},[122,2726,168],{},[122,2728,171],{},[122,2730,174],{},[104,2732,2733,2735,2737],{},[122,2734,179],{},[122,2736,182],{},[122,2738,185],{},[104,2740,2741,2743,2745],{},[122,2742,190],{},[122,2744,193],{},[122,2746,196],{},[104,2748,2749,2751,2753],{},[122,2750,201],{},[122,2752,204],{},[122,2754,196],{},[45,2756],{},[48,2758,212],{"id":211},[15,2760,215,2761,219,2763,223],{},[19,2762,218],{},[19,2764,222],{},[98,2766,2767,2779],{},[101,2768,2769],{},[104,2770,2771,2773,2775,2777],{},[107,2772,232],{},[107,2774,235],{},[107,2776,238],{},[107,2778,241],{},[117,2780,2781,2793,2805,2817,2829,2841,2853,2865,2877,2889],{},[104,2782,2783,2785,2787,2791],{},[122,2784,248],{},[122,2786,251],{},[122,2788,2789],{},[19,2790,256],{},[122,2792,259],{},[104,2794,2795,2797,2799,2803],{},[122,2796,264],{},[122,2798,267],{},[122,2800,2801],{},[19,2802,272],{},[122,2804,259],{},[104,2806,2807,2809,2811,2815],{},[122,2808,279],{},[122,2810,282],{},[122,2812,2813],{},[19,2814,287],{},[122,2816,290],{},[104,2818,2819,2821,2823,2827],{},[122,2820,295],{},[122,2822,298],{},[122,2824,2825],{},[19,2826,303],{},[122,2828,306],{},[104,2830,2831,2833,2835,2839],{},[122,2832,311],{},[122,2834,314],{},[122,2836,2837],{},[19,2838,319],{},[122,2840,322],{},[104,2842,2843,2845,2847,2851],{},[122,2844,327],{},[122,2846,330],{},[122,2848,2849],{},[19,2850,335],{},[122,2852,338],{},[104,2854,2855,2857,2859,2863],{},[122,2856,343],{},[122,2858,346],{},[122,2860,2861],{},[19,2862,351],{},[122,2864,354],{},[104,2866,2867,2869,2871,2875],{},[122,2868,359],{},[122,2870,362],{},[122,2872,2873],{},[19,2874,367],{},[122,2876,370],{},[104,2878,2879,2881,2883,2887],{},[122,2880,375],{},[122,2882,378],{},[122,2884,2885],{},[19,2886,383],{},[122,2888,386],{},[104,2890,2891,2893,2895,2899],{},[122,2892,391],{},[122,2894,394],{},[122,2896,2897],{},[19,2898,399],{},[122,2900,402],{},[24,2902,2903],{},[15,2904,2905,410],{},[19,2906,409],{},[45,2908],{},[48,2910,416],{"id":415},[15,2912,419],{},[53,2914,423],{"id":422},[66,2916,2917,2921,2925,2929,2933],{},[69,2918,428,2919,432],{},[19,2920,431],{},[69,2922,2923,438],{},[19,2924,437],{},[69,2926,2927,444],{},[19,2928,443],{},[69,2930,2931,450],{},[19,2932,449],{},[69,2934,2935,456],{},[19,2936,455],{},[53,2938,460],{"id":459},[66,2940,2941,2945,2949],{},[69,2942,2943,468],{},[19,2944,467],{},[69,2946,2947,474],{},[19,2948,473],{},[69,2950,477,2951,82],{},[19,2952,480],{},[53,2954,484],{"id":483},[66,2956,2957,2961,2965],{},[69,2958,2959,492],{},[19,2960,491],{},[69,2962,2963,498],{},[19,2964,497],{},[69,2966,501,2967,82],{},[19,2968,504],{},[53,2970,508],{"id":507},[15,2972,511],{},[66,2974,2975,2979,2983,2987],{},[69,2976,516,2977,520],{},[19,2978,519],{},[69,2980,516,2981,526],{},[19,2982,525],{},[69,2984,2985,532],{},[19,2986,531],{},[69,2988,535],{},[53,2990,539],{"id":538},[66,2992,2993,2997,3001],{},[69,2994,2995,547],{},[19,2996,546],{},[69,2998,2999,553],{},[19,3000,552],{},[69,3002,3003,559],{},[19,3004,558],{},[45,3006],{},[48,3008,565],{"id":564},[15,3010,568,3011,572],{},[19,3012,571],{},[15,3014,3015],{},[19,3016,577],{},[579,3018,3019,3021,3023],{},[69,3020,583],{},[69,3022,586],{},[69,3024,589],{},[15,3026,3027],{},[19,3028,594],{},[66,3030,3031,3033,3035,3037],{},[69,3032,599],{},[69,3034,602],{},[69,3036,605],{},[69,3038,608],{},[24,3040,3041,3047],{},[15,3042,3043,615,3045,619],{},[19,3044,64],{},[19,3046,618],{},[15,3048,3049,625],{},[19,3050,624],{},[45,3052],{},[48,3054,631],{"id":630},[15,3056,634],{},[66,3058,3059,3063,3067,3071],{},[69,3060,3061,642],{},[19,3062,641],{},[69,3064,3065,648],{},[19,3066,647],{},[69,3068,3069,654],{},[19,3070,653],{},[69,3072,3073,660],{},[19,3074,659],{},[45,3076],{},[48,3078,666],{"id":665},[98,3080,3081,3091],{},[101,3082,3083],{},[104,3084,3085,3087,3089],{},[107,3086,675],{},[107,3088,678],{},[107,3090,681],{},[117,3092,3093,3101,3109,3117,3125,3133,3141],{},[104,3094,3095,3097,3099],{},[122,3096,688],{},[122,3098,691],{},[122,3100,694],{},[104,3102,3103,3105,3107],{},[122,3104,699],{},[122,3106,702],{},[122,3108,705],{},[104,3110,3111,3113,3115],{},[122,3112,710],{},[122,3114,713],{},[122,3116,716],{},[104,3118,3119,3121,3123],{},[122,3120,721],{},[122,3122,713],{},[122,3124,726],{},[104,3126,3127,3129,3131],{},[122,3128,731],{},[122,3130,734],{},[122,3132,737],{},[104,3134,3135,3137,3139],{},[122,3136,742],{},[122,3138,691],{},[122,3140,747],{},[104,3142,3143,3145,3147],{},[122,3144,752],{},[122,3146,713],{},[122,3148,757],{},[45,3150],{},[48,3152,763],{"id":762},[66,3154,3156,3161,3166,3171,3176,3181,3186,3191,3196,3201],{"className":3155},[767],[69,3157,3159,777],{"className":3158},[771],[773,3160],{"disabled":775,"type":776},[69,3162,3164,783],{"className":3163},[771],[773,3165],{"disabled":775,"type":776},[69,3167,3169,789],{"className":3168},[771],[773,3170],{"disabled":775,"type":776},[69,3172,3174,795],{"className":3173},[771],[773,3175],{"disabled":775,"type":776},[69,3177,3179,801],{"className":3178},[771],[773,3180],{"disabled":775,"type":776},[69,3182,3184,807],{"className":3183},[771],[773,3185],{"disabled":775,"type":776},[69,3187,3189,813],{"className":3188},[771],[773,3190],{"disabled":775,"type":776},[69,3192,3194,819],{"className":3193},[771],[773,3195],{"disabled":775,"type":776},[69,3197,3199,825],{"className":3198},[771],[773,3200],{"disabled":775,"type":776},[69,3202,3204,831],{"className":3203},[771],[773,3205],{"disabled":775,"type":776},[45,3207],{},[48,3209,837],{"id":836},[66,3211,3212,3216,3220],{},[69,3213,3214],{},[843,3215,846],{"href":845},[69,3217,3218],{},[843,3219,852],{"href":851},[69,3221,3222],{},[843,3223,858],{"href":857},[45,3225],{},[15,3227,3228],{},[33,3229,865,3230,869,3232],{},[19,3231,868],{},[843,3233,873],{"href":872},{"title":875,"searchDepth":876,"depth":876,"links":3235},[3236,3240,3241,3248,3249,3250,3251,3252],{"id":50,"depth":876,"text":51,"children":3237},[3238,3239],{"id":55,"depth":881,"text":56},{"id":92,"depth":881,"text":93},{"id":211,"depth":876,"text":212},{"id":415,"depth":876,"text":416,"children":3242},[3243,3244,3245,3246,3247],{"id":422,"depth":881,"text":423},{"id":459,"depth":881,"text":460},{"id":483,"depth":881,"text":484},{"id":507,"depth":881,"text":508},{"id":538,"depth":881,"text":539},{"id":564,"depth":876,"text":565},{"id":630,"depth":876,"text":631},{"id":665,"depth":876,"text":666},{"id":762,"depth":876,"text":763},{"id":836,"depth":876,"text":837},{},{"title":5,"description":898},[909,910,911,896,912,913,914],{"id":3257,"title":3258,"articleId":6,"body":3259,"category":896,"date":897,"description":4093,"extension":899,"lastUpdated":897,"locale":4094,"meta":4095,"navigation":775,"path":4096,"publishDate":897,"readTime":903,"refreshInterval":904,"seo":4097,"slug":4098,"stem":4099,"tags":4100,"__hash__":4106},"blog\u002Fblog\u002Fdraw-situation-plan.nl.md","Situatieschema tekenen: Stap-voor-stap handleiding volgens AREI",{"type":8,"value":3260,"toc":4074},[3261,3264,3271,3287,3290,3292,3296,3300,3303,3308,3331,3335,3338,3431,3433,3437,3447,3615,3622,3624,3628,3631,3635,3667,3671,3691,3695,3716,3720,3723,3746,3750,3770,3772,3776,3783,3788,3799,3804,3818,3835,3837,3841,3844,3869,3871,3875,3966,3968,3972,4035,4037,4041,4061,4063],[11,3262,3258],{"id":3263},"situatieschema-tekenen-stap-voor-stap-handleiding-volgens-arei",[15,3265,3266,3267,3270],{},"Het situatieschema (ook wel situatieplan of plan de situation) toont ",[19,3268,3269],{},"waar precies"," elk elektrisch onderdeel zich in uw gebouw bevindt. Samen met het éénlijnschema is het één van de twee verplichte documenten voor elke elektrische installatie in België — zonder situatieschema slaagt de keuring door het erkend controleorganisme niet.",[24,3272,3273],{},[15,3274,3275,3278,3279,3282,3283,3286],{},[19,3276,3277],{},"Kort uitgelegd:"," Terwijl het éénlijnschema de ",[33,3280,3281],{},"logische schakeling"," weergeeft (welke schakelaar bedient welk lichtpunt, via welk circuit), toont het situatieschema de ",[33,3284,3285],{},"fysieke positie"," van elk onderdeel op het grondplan.",[15,3288,3289],{},"In deze handleiding leert u hoe u stap voor stap een normconform situatieschema maakt.",[45,3291],{},[48,3293,3295],{"id":3294},"stap-1-grondplan-voorbereiden","Stap 1: Grondplan voorbereiden",[53,3297,3299],{"id":3298},"afmetingen-en-schaal","Afmetingen en schaal",[15,3301,3302],{},"Het grondplan vormt de basis van uw situatieschema. U kunt het overnemen van een bouwplan of zelf tekenen.",[15,3304,3305],{},[19,3306,3307],{},"Belangrijk:",[66,3309,3310,3317,3324],{},[69,3311,3312,3313,3316],{},"Gebruik een ",[19,3314,3315],{},"uniforme schaal"," (gebruikelijk: 1:50 of 1:100).",[69,3318,3319,3320,3323],{},"Teken alle ",[19,3321,3322],{},"muren, deuren en ramen"," in.",[69,3325,3326,3327,3330],{},"Markeer de ",[19,3328,3329],{},"openingsrichting"," van deuren (kwartcirkel) — dit beïnvloedt de schakelaarspositie.",[53,3332,3334],{"id":3333},"ruimtes-labelen","Ruimtes labelen",[15,3336,3337],{},"Voorzie elke ruimte van een benaming en idealiter het oppervlak:",[98,3339,3340,3353],{},[101,3341,3342],{},[104,3343,3344,3347,3350],{},[107,3345,3346],{},"Afkorting",[107,3348,3349],{},"Ruimte",[107,3351,3352],{},"Typisch oppervlak",[117,3354,3355,3365,3374,3384,3394,3403,3411,3421],{},[104,3356,3357,3360,3363],{},[122,3358,3359],{},"WK",[122,3361,3362],{},"Woonkamer",[122,3364,130],{},[104,3366,3367,3369,3372],{},[122,3368,1079],{},[122,3370,3371],{},"Keuken",[122,3373,141],{},[104,3375,3376,3379,3382],{},[122,3377,3378],{},"SK",[122,3380,3381],{},"Slaapkamer",[122,3383,152],{},[104,3385,3386,3389,3392],{},[122,3387,3388],{},"BK",[122,3390,3391],{},"Badkamer",[122,3393,163],{},[104,3395,3396,3398,3401],{},[122,3397,1916],{},[122,3399,3400],{},"Hal\u002FGang",[122,3402,174],{},[104,3404,3405,3407,3409],{},[122,3406,1070],{},[122,3408,182],{},[122,3410,185],{},[104,3412,3413,3416,3419],{},[122,3414,3415],{},"KL",[122,3417,3418],{},"Kelder",[122,3420,1085],{},[104,3422,3423,3426,3429],{},[122,3424,3425],{},"BU",[122,3427,3428],{},"Buitenzone",[122,3430,1085],{},[45,3432],{},[48,3434,3436],{"id":3435},"stap-2-arei-symbolen-gebruiken","Stap 2: AREI-symbolen gebruiken",[15,3438,3439,3440,3443,3444,3446],{},"Het AREI schrijft in ",[19,3441,3442],{},"Tabel 2.23"," precies voor welke symbolen gebruikt moeten worden. Deze zijn gebaseerd op de norm ",[19,3445,222],{},". Hier de 10 belangrijkste symbolen voor het situatieschema:",[98,3448,3449,3464],{},[101,3450,3451],{},[104,3452,3453,3455,3458,3461],{},[107,3454,1120],{},[107,3456,3457],{},"Symbool",[107,3459,3460],{},"Beschrijving",[107,3462,3463],{},"Gebruik",[117,3465,3466,3481,3495,3510,3525,3540,3555,3570,3585,3600],{},[104,3467,3468,3470,3473,3478],{},[122,3469,248],{},[122,3471,3472],{},"⏚ Halve cirkel",[122,3474,3475],{},[19,3476,3477],{},"Enkel stopcontact",[122,3479,3480],{},"Wandpositie markeren",[104,3482,3483,3485,3488,3493],{},[122,3484,264],{},[122,3486,3487],{},"⏚⏚ Dubbele halve cirkel",[122,3489,3490],{},[19,3491,3492],{},"Dubbel stopcontact",[122,3494,3480],{},[104,3496,3497,3499,3502,3507],{},[122,3498,279],{},[122,3500,3501],{},"○ met kruis",[122,3503,3504],{},[19,3505,3506],{},"Plafondlamp",[122,3508,3509],{},"Midden van de ruimte\u002Fpositie",[104,3511,3512,3514,3517,3522],{},[122,3513,295],{},[122,3515,3516],{},"─○ met streep",[122,3518,3519],{},[19,3520,3521],{},"Wandlamp",[122,3523,3524],{},"Aan de wand",[104,3526,3527,3529,3532,3537],{},[122,3528,311],{},[122,3530,3531],{},"Schakelaarsteken",[122,3533,3534],{},[19,3535,3536],{},"Enkelpolige schakelaar",[122,3538,3539],{},"Naast de deur (openingszijde)",[104,3541,3542,3544,3547,3552],{},[122,3543,327],{},[122,3545,3546],{},"Schakelaarsteken met 2 pijlen",[122,3548,3549],{},[19,3550,3551],{},"Serieschakelaar",[122,3553,3554],{},"Bedient 2 lichtpunten",[104,3556,3557,3559,3562,3567],{},[122,3558,343],{},[122,3560,3561],{},"Schakelaarsteken met lijn",[122,3563,3564],{},[19,3565,3566],{},"Wisselschakelaar",[122,3568,3569],{},"Twee plaatsen, één licht",[104,3571,3572,3574,3577,3582],{},[122,3573,359],{},[122,3575,3576],{},"Rechthoek met bliksem",[122,3578,3579],{},[19,3580,3581],{},"Verdeelkast",[122,3583,3584],{},"Meestal hal\u002Ftechnische ruimte",[104,3586,3587,3589,3592,3597],{},[122,3588,375],{},[122,3590,3591],{},"⏚ met PE",[122,3593,3594],{},[19,3595,3596],{},"Aardingsaansluiting",[122,3598,3599],{},"Aardingspunt",[104,3601,3602,3604,3607,3612],{},[122,3603,391],{},[122,3605,3606],{},"Cirkel met R",[122,3608,3609],{},[19,3610,3611],{},"Rookmelder",[122,3613,3614],{},"Elke slaapkamer, hal, trappenhuis",[24,3616,3617],{},[15,3618,3619,3621],{},[19,3620,2139],{}," Gebruik uitsluitend de AREI-symbolen. Eigen verzonnen symbolen worden bij de keuring afgekeurd.",[45,3623],{},[48,3625,3627],{"id":3626},"stap-3-componenten-intekenen","Stap 3: Componenten intekenen",[15,3629,3630],{},"Nu plaatst u de symbolen op het grondplan. Volgende regels helpen bij de correcte positionering:",[53,3632,3634],{"id":3633},"stopcontacten","Stopcontacten",[66,3636,3637,3643,3649,3655,3661],{},[69,3638,3639,3642],{},[19,3640,3641],{},"Op de wand"," tekenen, op de werkelijke positie.",[69,3644,3645,3648],{},[19,3646,3647],{},"Keuken:"," werkblad minstens 4 stopcontacten, waarvan 2 boven het werkblad. Aparte stopcontacten voor oven, vaatwasser, koelkast.",[69,3650,3651,3654],{},[19,3652,3653],{},"Woonruimtes:"," Minstens 1 stopcontact per begonnen 4 m² (praktijkaanbeveling van de installateurverenigingen — het AREI schrijft geen minimumaantal stopcontacten per oppervlakte voor).",[69,3656,3657,3660],{},[19,3658,3659],{},"Badkamer:"," Laagspanningsstopcontacten pas vanaf zone 2 (alleen bij badkuipen, met 30mA differentieel) of buiten de zones. Bij douches bestaat zone 2 niet (Art. 7.1.3.2 Nr. 3b, Art. 7.1.5.2d).",[69,3662,3663,3666],{},[19,3664,3665],{},"Buiten:"," Indien aanwezig, moet een buitenstopcontact weerbestendig zijn (IP44) en met eigen 30mA differentieel beveiligd zijn.",[53,3668,3670],{"id":3669},"schakelaars","Schakelaars",[66,3672,3673,3679,3685],{},[69,3674,3675,3678],{},[19,3676,3677],{},"Naast de deur"," aan de openingszijde, ca. 105 cm hoogte (praktijkaanbeveling — het AREI schrijft geen specifieke schakelaarhoogte voor, maar vereist wel 'gemakkelijk bereikbaar').",[69,3680,3681,3684],{},[19,3682,3683],{},"Wisselschakelaars"," bij ruimtes met meerdere ingangen of aan het begin\u002Feinde van de trap.",[69,3686,3687,3688,82],{},"Verbind schakelaars en bijbehorende lichtpunten met een ",[19,3689,3690],{},"stippellijn",[53,3692,3694],{"id":3693},"verlichtingspunten","Verlichtingspunten",[66,3696,3697,3703,3709],{},[69,3698,3699,3702],{},[19,3700,3701],{},"Plafondlampen"," in het midden van de ruimte of op de geplande positie.",[69,3704,3705,3708],{},[19,3706,3707],{},"Wandlampen"," op de wandpositie.",[69,3710,3711,3712,3715],{},"Elke ruimte heeft minstens ",[19,3713,3714],{},"één lichtpunt"," nodig.",[53,3717,3719],{"id":3718},"rookmelders","Rookmelders",[15,3721,3722],{},"Verplicht volgens de Belgische brandveiligheidswetgeving (regionaal verschillend):",[66,3724,3725,3731,3737,3743],{},[69,3726,1390,3727,3730],{},[19,3728,3729],{},"Vlaanderen:"," Verplicht in vluchtwegen (gangen, trappenhuizen); in slaapkamers aanbevolen maar niet verplicht.",[69,3732,1390,3733,3736],{},[19,3734,3735],{},"Wallonië en Brussel"," gelden eigen regelingen.",[69,3738,3739,3742],{},[19,3740,3741],{},"Gangen en trappenhuizen"," — minstens een rookmelder per verdieping.",[69,3744,3745],{},"In de keuken optioneel (hittemelder heeft de voorkeur wegens vals alarm).",[53,3747,3749],{"id":3748},"speciale-verbruikers","Speciale verbruikers",[66,3751,3752,3758,3764],{},[69,3753,3754,3757],{},[19,3755,3756],{},"Laadpaal"," (elektrisch voertuig): garage of buitenmuur, eigen circuit.",[69,3759,3760,3763],{},[19,3761,3762],{},"Boiler\u002FDoorstromer:"," Eigen circuit, positie intekenen.",[69,3765,3766,3769],{},[19,3767,3768],{},"Warmtepomp\u002FAirco:"," Buitenunit + binnenunit markeren.",[45,3771],{},[48,3773,3775],{"id":3774},"stap-4-circuitnummers-toewijzen","Stap 4: Circuitnummers toewijzen",[15,3777,3778,3779,3782],{},"Elk onderdeel in het situatieschema krijgt ",[19,3780,3781],{},"hetzelfde circuitnummer"," als in het éénlijnschema. Dit is essentieel voor de toewijzing bij de keuring.",[15,3784,3785],{},[19,3786,3787],{},"Zo werkt het:",[579,3789,3790,3793,3796],{},[69,3791,3792],{},"Nummer uw circuits in het éénlijnschema (1, 2, 3, ...).",[69,3794,3795],{},"Schrijf het nummer bij elk onderdeel in het situatieschema.",[69,3797,3798],{},"Gebruik een uniforme notatie: bijv. \"K1\" voor kring 1 of gewoon \"1\".",[15,3800,3801],{},[19,3802,3803],{},"Voorbeeld:",[66,3805,3806,3809,3812,3815],{},[69,3807,3808],{},"Circuit 1: Verlichting gelijkvloers → Alle lichtpunten op het gelijkvloers krijgen \"1\".",[69,3810,3811],{},"Circuit 2: Stopcontacten woonkamer → Alle WK-stopcontacten krijgen \"2\".",[69,3813,3814],{},"Circuit 3: Stopcontacten keuken → Alle KE-stopcontacten krijgen \"3\".",[69,3816,3817],{},"Circuit 4: Apart oven → Eén stopcontact met \"4\".",[24,3819,3820,3829],{},[15,3821,3822,3824,3825,3828],{},[19,3823,3307],{}," De nummers moeten tussen éénlijnschema en situatieschema ",[19,3826,3827],{},"exact overeenkomen",". Inconsistenties zijn een van de meest voorkomende redenen voor opmerkingen bij de keuring.",[15,3830,3831,3834],{},[19,3832,3833],{},"Documentatieplicht:"," Art. 9.1.2 Nr. 1 (éénlijnschema) en Art. 9.1.2 Nr. 2 (situatieschema\u002Flageplan).",[45,3836],{},[48,3838,3840],{"id":3839},"stap-5-legende-en-opschrift","Stap 5: Legende en opschrift",[15,3842,3843],{},"Vul uw plan aan met:",[66,3845,3846,3851,3857,3863],{},[69,3847,3848,3850],{},[19,3849,1514],{}," met alle gebruikte symbolen en hun betekenis.",[69,3852,3853,3856],{},[19,3854,3855],{},"Titelblok"," (cartouche) met: naam eigenaar, adres, datum, planmaker, schaal.",[69,3858,3859,3862],{},[19,3860,3861],{},"Noordpijl"," (optioneel, maar nuttig).",[69,3864,3865,3868],{},[19,3866,3867],{},"Verdiepingsaanduiding"," bij gebouwen met meerdere verdiepingen (één plan per verdieping).",[45,3870],{},[48,3872,3874],{"id":3873},"veelgemaakte-fouten","Veelgemaakte fouten",[98,3876,3877,3890],{},[101,3878,3879],{},[104,3880,3881,3884,3887],{},[107,3882,3883],{},"Fout",[107,3885,3886],{},"Gevolg",[107,3888,3889],{},"Oplossing",[117,3891,3892,3903,3914,3925,3935,3946,3956],{},[104,3893,3894,3897,3900],{},[122,3895,3896],{},"Ontbrekende rookmelders",[122,3898,3899],{},"Keuring niet geslaagd",[122,3901,3902],{},"Min. 1 per verdieping in vluchtwegen (regionaal verschillend)",[104,3904,3905,3908,3911],{},[122,3906,3907],{},"Buitenstopcontact niet normconform",[122,3909,3910],{},"Opmerking, indien aanwezig maar niet conform",[122,3912,3913],{},"Indien geïnstalleerd: IP44, eigen 30mA differentieel. Een ontbrekend buitenstopcontact is geen reden voor afkeuring",[104,3915,3916,3919,3922],{},[122,3917,3918],{},"Ontbrekende opschriften \u002F circuitnummers",[122,3920,3921],{},"Opmerking",[122,3923,3924],{},"Elk onderdeel nummeren",[104,3926,3927,3930,3932],{},[122,3928,3929],{},"Verkeerde symbolen",[122,3931,3921],{},[122,3933,3934],{},"Alleen AREI Tabel 2.23 gebruiken",[104,3936,3937,3940,3943],{},[122,3938,3939],{},"Schakelaar aan verkeerde deurzijde",[122,3941,3942],{},"Onpraktisch (geen AREI-overtreding)",[122,3944,3945],{},"Openingsrichting controleren",[104,3947,3948,3951,3953],{},[122,3949,3950],{},"Badkamer-stopcontact in zone 0 of 1",[122,3952,3899],{},[122,3954,3955],{},"Stopcontacten pas vanaf zone 2 (alleen badkuip) of buiten de zones (douche) toegelaten (Art. 7.1.5.2c\u002Fd)",[104,3957,3958,3961,3963],{},[122,3959,3960],{},"Geen legende",[122,3962,3921],{},[122,3964,3965],{},"Symbooltabel bijvoegen",[45,3967],{},[48,3969,3971],{"id":3970},"checklist-voor-indiening","Checklist voor indiening",[66,3973,3975,3981,3987,3993,3999,4005,4011,4017,4023,4029],{"className":3974},[767],[69,3976,3978,3980],{"className":3977},[771],[773,3979],{"disabled":775,"type":776}," Alle ruimtes gelabeld",[69,3982,3984,3986],{"className":3983},[771],[773,3985],{"disabled":775,"type":776}," Alle stopcontacten, schakelaars, lichtpunten ingetekend",[69,3988,3990,3992],{"className":3989},[771],[773,3991],{"disabled":775,"type":776}," Rookmelders in vluchtwegen (min. 1 per verdieping, regionaal verschillend)",[69,3994,3996,3998],{"className":3995},[771],[773,3997],{"disabled":775,"type":776}," Buitenstopcontacten, indien aanwezig, normconform (IP44, eigen 30mA differentieel)",[69,4000,4002,4004],{"className":4001},[771],[773,4003],{"disabled":775,"type":776}," Circuitnummers bij elk onderdeel",[69,4006,4008,4010],{"className":4007},[771],[773,4009],{"disabled":775,"type":776}," Nummers komen overeen met éénlijnschema",[69,4012,4014,4016],{"className":4013},[771],[773,4015],{"disabled":775,"type":776}," AREI-symbolen gebruikt (Tabel 2.23)",[69,4018,4020,4022],{"className":4019},[771],[773,4021],{"disabled":775,"type":776}," Legende aanwezig",[69,4024,4026,4028],{"className":4025},[771],[773,4027],{"disabled":775,"type":776}," Titelblok met naam, adres, datum",[69,4030,4032,4034],{"className":4031},[771],[773,4033],{"disabled":775,"type":776}," Eén plan per verdieping",[45,4036],{},[48,4038,4040],{"id":4039},"gerelateerde-artikelen","Gerelateerde artikelen",[66,4042,4043,4049,4055],{},[69,4044,4045],{},[843,4046,4048],{"href":4047},"\u002Fblog\u002Fwat-is-eenlijnschema","Wat is een éénlijnschema?",[69,4050,4051],{},[843,4052,4054],{"href":4053},"\u002Fblog\u002Felektrische-keuring","Elektrische keuring in België",[69,4056,4057],{},[843,4058,4060],{"href":4059},"\u002Fblog\u002Fverdeelkast-plannen-opbouw","Verdeelkast plannen: Opbouw en dimensionering",[45,4062],{},[15,4064,4065],{},[33,4066,4067,4068,4070,4071],{},"Met ",[19,4069,868],{}," maakt u uw situatieschema rechtstreeks vanuit het grondplan — ruimtes tekenen, apparaten slepen en neerzetten, AREI-symbolen worden automatisch gebruikt. ",[843,4072,4073],{"href":872},"Nu gratis uitproberen →",{"title":875,"searchDepth":876,"depth":876,"links":4075},[4076,4080,4081,4088,4089,4090,4091,4092],{"id":3294,"depth":876,"text":3295,"children":4077},[4078,4079],{"id":3298,"depth":881,"text":3299},{"id":3333,"depth":881,"text":3334},{"id":3435,"depth":876,"text":3436},{"id":3626,"depth":876,"text":3627,"children":4082},[4083,4084,4085,4086,4087],{"id":3633,"depth":881,"text":3634},{"id":3669,"depth":881,"text":3670},{"id":3693,"depth":881,"text":3694},{"id":3718,"depth":881,"text":3719},{"id":3748,"depth":881,"text":3749},{"id":3774,"depth":876,"text":3775},{"id":3839,"depth":876,"text":3840},{"id":3873,"depth":876,"text":3874},{"id":3970,"depth":876,"text":3971},{"id":4039,"depth":876,"text":4040},"Volledige handleiding voor het maken van een AREI-conform situatieschema. Van de grondplanvoorbereiding via AREI-symbolen tot de afgewerkte tekening.","nl",{},"\u002Fblog\u002Fdraw-situation-plan.nl",{"title":3258,"description":4093},"situatieschema-tekenen-handleiding","blog\u002Fdraw-situation-plan.nl",[4101,1767,4102,4103,4104,1771,4105],"situatieschema","symbolen","handleiding","tekenen","grondplan","xX_iD9De_y0ZulcG-M5dx4Pg6-zcCmVgi-8BfBtEtC8",1775151659058]