[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"help-guide-fr-importer-des-projets-trikker":3,"help-alternates-trikker-import":869,"help-related-fr":3916},{"id":4,"title":5,"body":6,"category":844,"description":845,"extension":846,"guideId":847,"image":848,"locale":849,"meta":850,"navigation":851,"order":852,"path":853,"publishedAt":854,"readTime":855,"seo":856,"seoTitle":857,"slug":858,"stem":859,"tags":860,"updatedAt":867,"__hash__":868},"help\u002Fhelp\u002Ftrikker-import.fr.md","Comment importer mes projets Trikker dans PlanElec ?",{"type":7,"value":8,"toc":821},"minimark",[9,23,29,34,127,139,144,148,176,181,185,244,251,256,260,382,389,394,461,466,470,473,536,539,544,548,660,663,668,672,678,683,687,741,744,749,753,767,771,775,778,782,785,789,799,803,806,810,813],[10,11,12,13,17,18,22],"p",{},"Un projet Trikker est un fichier ",[14,15,16],"code",{},".trik",". ",[19,20,21],"strong",{},"Vous l’importez dans PlanElec Pro avec l’entrée « Importer des projets Trikker » : un seul fichier comme plusieurs fichiers, un dossier ou une archive ZIP de 500 fichiers au maximum."," Chaque fichier devient un projet distinct, et l’original reste joint au projet sous forme de fichier. Le schéma unifilaire, les tableaux, les circuits et les appareils sont repris ; le plan de position reste en arrière. Il vous faut un compte PlanElec connecté ; un abonnement Pro n’est pas nécessaire, « Essayer Pro » suffit. Sans compte, vous ouvrez un fichier isolé dans PlanElec Sketch.",[10,24,25],{},[26,27],"a",{"id":28},"ways",[30,31,33],"h2",{"id":32},"quelle-voie-convient-à-mes-données","Quelle voie convient à mes données ?",[35,36,37,53],"table",{},[38,39,40],"thead",{},[41,42,43,47,50],"tr",{},[44,45,46],"th",{},"Vous avez …",[44,48,49],{},"Votre voie",[44,51,52],{},"Compte",[54,55,56,74,92,108],"tbody",{},[41,57,58,65,71],{},[59,60,61,62,64],"td",{},"une archive de nombreux fichiers ",[14,63,16],{},", un dossier ou un ZIP",[59,66,67,70],{},[19,68,69],{},"Importer des projets Trikker"," dans PlanElec Pro (voie principale, voir ci-dessous)",[59,72,73],{},"compte PlanElec",[41,75,76,81,90],{},[59,77,78,79],{},"un seul fichier ",[14,80,16],{},[59,82,83,84,86,87],{},"la même voie : ",[19,85,69],{}," ; avec exactement un projet, le rapport propose ",[19,88,89],{},"Ouvrir le projet",[59,91,73],{},[41,93,94,99,105],{},[59,95,78,96,98],{},[14,97,16],{}," et pas de compte",[59,100,101,102],{},"PlanElec Sketch : ouvrir le fichier, vérifier le schéma puis, si vous le souhaitez, ",[19,103,104],{},"Reprendre dans Pro",[59,106,107],{},"aucun pour Sketch",[41,109,110,113,125],{},[59,111,112],{},"un plan en PDF, scan, image ou DXF",[59,114,115,116,120,121],{},"l’importer ou le faire reconnaître, voir ",[26,117,119],{"href":118},"\u002Ffr\u002Fhelp\u002Fimporter-et-etalonner-un-plan","Importer et étalonner un plan"," et ",[26,122,124],{"href":123},"\u002Ffr\u002Fhelp\u002Freconnaitre-un-plan-avec-l-ia","Faire reconnaître un plan par l’IA",[59,126,73],{},[10,128,129,130,132,133,135,136,138],{},"Notre recommandation : importez les fichiers ",[14,131,16],{}," avec ",[19,134,69],{},". C’est l’unique voie d’import dans Pro ; elle crée des projets dans votre compte et conserve l’original. Le plan de position du fichier ",[14,137,16],{}," est repris sur le plan : étages, murs, pièces, portes, fenêtres, portes de garage, escaliers et appareils placés.",[10,140,141],{},[26,142],{"id":143},"requirements",[30,145,147],{"id":146},"de-quoi-avez-vous-besoin-pour-limport","De quoi avez-vous besoin pour l’import ?",[149,150,151,158,170],"ul",{},[152,153,154,157],"li",{},[19,155,156],{},"Un compte PlanElec connecté."," L’import est ouvert à tout compte connecté, y compris avec « Essayer Pro ».",[152,159,160,165,166,169],{},[19,161,162,163],{},"Vos fichiers ",[14,164,16],{}," sur l’ordinateur que vous utilisez. Les sauvegardes automatiques de Trikker (",[14,167,168],{},".trikback",") ne sont pas des fichiers de projet ; laissez-les de côté.",[152,171,172,175],{},[19,173,174],{},"Un navigateur."," Il lit votre sélection, décompresse un ZIP et envoie chaque fichier. Tout le reste se passe sur le serveur.",[10,177,178],{},[26,179],{"id":180},"limits",[30,182,184],{"id":183},"quelles-limites-sappliquent","Quelles limites s’appliquent ?",[35,186,187,197],{},[38,188,189],{},[41,190,191,194],{},[44,192,193],{},"Limite",[44,195,196],{},"Valeur",[54,198,199,209,217,228,236],{},[41,200,201,204],{},[59,202,203],{},"Fichiers par import",[59,205,206,207],{},"jusqu’à 500 fichiers ",[14,208,16],{},[41,210,211,214],{},[59,212,213],{},"Archive ZIP",[59,215,216],{},"jusqu’à 200 Mo",[41,218,219,225],{},[59,220,221,222,224],{},"Un fichier ",[14,223,16],{}," décompressé",[59,226,227],{},"jusqu’à 5 Mo",[41,229,230,233],{},[59,231,232],{},"Tous les fichiers décompressés ensemble",[59,234,235],{},"jusqu’à 500 Mo",[41,237,238,241],{},[59,239,240],{},"Imports simultanés",[59,242,243],{},"un par compte ; un deuxième ne démarre qu’une fois le premier terminé ou annulé",[10,245,246,247,250],{},"Les fichiers et dossiers cachés comme ",[14,248,249],{},"__MACOSX",", ainsi qu’un ZIP dans un ZIP, sont ignorés. Si votre archive est plus volumineuse, scindez-la et importez en plusieurs fois. Les doublons sont reconnus, un chevauchement ne pose donc pas de problème.",[10,252,253],{},[26,254],{"id":255},"steps",[30,257,259],{"id":258},"comment-se-déroule-limport-pas-à-pas","Comment se déroule l’import pas à pas ?",[261,262,263,280,298,312,326,336,346,352,370,376],"ol",{},[152,264,265,268,269,271,272,275,276,279],{},[19,266,267],{},"Ouvrez l’import."," Vous trouvez ",[19,270,69],{}," à trois endroits : dans le menu du logo d’un projet (avec le badge ",[19,273,274],{},"Nouveau","), dans la liste des projets à côté de ",[19,277,278],{},"Nouveau projet"," et dans la palette de commandes. Tous ouvrent la même page.",[152,281,282,285,286,289,290,293,294,297],{},[19,283,284],{},"Choisissez vos fichiers."," Déposez des fichiers, un dossier ou un ZIP sur ",[19,287,288],{},"Glissez ici des fichiers, un dossier ou un ZIP",", ou utilisez ",[19,291,292],{},"Choisir des fichiers"," ou ",[19,295,296],{},"Choisir un dossier",". Les sous-dossiers sont lus ; le chemin du dossier de chaque fichier est conservé.",[152,299,300,303,304,307,308,311],{},[19,301,302],{},"Vérifiez l’aperçu."," La liste affiche ",[19,305,306],{},"50 fichiers vérifiés"," et un statut par fichier (tableau ci-dessous). Rien n’est encore créé. Ouvrez les détails d’un fichier avec remarques pour lire ce qui n’est pas repris. ",[19,309,310],{},"Vider la sélection"," permet de recommencer.",[152,313,314,317,318,321,322,325],{},[19,315,316],{},"Choisissez la destination."," Sous ",[19,319,320],{},"Créer dans"," figurent ",[19,323,324],{},"Mes projets"," et les organisations auxquelles vous appartenez.",[152,327,328,331,332,335],{},[19,329,330],{},"Décidez pour le consentement."," ",[19,333,334],{},"Utiliser les fichiers pour améliorer l’import"," est facultatif et désactivé par défaut (voir confidentialité ci-dessous).",[152,337,338,341,342,345],{},[19,339,340],{},"Lancez."," Le bouton s’intitule ",[19,343,344],{},"Créer 48 projets",". Les doublons et les erreurs sont ignorés.",[152,347,348,351],{},[19,349,350],{},"Attendez la fin de l’envoi des fichiers."," Le message « Tous les fichiers sont envoyés. Vous pouvez fermer cette fenêtre : nous vous envoyons un e-mail dès que tout est prêt. » apparaît alors. Jusque-là, gardez la fenêtre ouverte.",[152,353,354,357,358,361,362,365,366,369],{},[19,355,356],{},"Suivez la progression ou fermez la fenêtre."," La page ",[19,359,360],{},"Vos projets Trikker sont en cours de création"," affiche l’état, le temps restant estimé et, sous ",[19,363,364],{},"Reconnu jusqu’ici",", des compteurs tels que circuits, appareils de protection, prises, points lumineux et tableaux. Les projets déjà créés apparaissent tout de suite dans votre liste de projets. ",[19,367,368],{},"Annuler le reste"," arrête l’import ; les projets terminés restent.",[152,371,372,375],{},[19,373,374],{},"Lisez l’e-mail."," Dès que chaque fichier a un état final, PlanElec envoie exactement un e-mail à votre compte, dans la langue de l’import, avec des chiffres et un lien vers le rapport. Il ne contient ni noms de fichiers ni noms de clients.",[152,377,378,381],{},[19,379,380],{},"Ouvrez le rapport."," Voir la section suivante.",[10,383,384,385,388],{},"Critère de réussite : le rapport s’intitule ",[19,386,387],{},"48 projets créés"," et les projets figurent dans la liste choisie.",[390,391,393],"h3",{"id":392},"quels-statuts-laperçu-affiche-t-il","Quels statuts l’aperçu affiche-t-il ?",[35,395,396,409],{},[38,397,398],{},[41,399,400,403,406],{},[44,401,402],{},"Statut",[44,404,405],{},"Signification",[44,407,408],{},"Ce qui se passe au lancement",[54,410,411,424,436,449],{},[41,412,413,418,421],{},[59,414,415],{},[19,416,417],{},"Prêt",[59,419,420],{},"Le fichier est lisible.",[59,422,423],{},"Un projet est créé.",[41,425,426,431,434],{},[59,427,428],{},[19,429,430],{},"avec remarques",[59,432,433],{},"Le fichier est lisible, mais certaines parties sont adaptées ou non reprises. Les détails les nomment.",[59,435,423],{},[41,437,438,443,446],{},[59,439,440],{},[19,441,442],{},"Doublon",[59,444,445],{},"Le même fichier (même contenu, pas forcément le même nom) a déjà été importé dans la destination choisie ou figure deux fois dans l’import.",[59,447,448],{},"Ignoré.",[41,450,451,456,459],{},[59,452,453],{},[19,454,455],{},"Erreur",[59,457,458],{},"Le fichier n’est pas un fichier Trikker lisible.",[59,460,448],{},[10,462,463],{},[26,464],{"id":465},"report",[30,467,469],{"id":468},"que-montre-le-rapport","Que montre le rapport ?",[10,471,472],{},"Le rapport s’ouvre par le lien de l’e-mail ou, si vous revenez, sur la même page. Il indique le nombre de projets créés, réparti entre sans remarques, avec remarques, doublons ignorés et fichiers non importés.",[35,474,475,485],{},[38,476,477],{},[41,478,479,482],{},[44,480,481],{},"Bouton",[44,483,484],{},"Effet",[54,486,487,497,506,516,526],{},[41,488,489,494],{},[59,490,491],{},[19,492,493],{},"Voir les projets",[59,495,496],{},"ouvre la liste des projets avec les nouveaux projets",[41,498,499,503],{},[59,500,501],{},[19,502,89],{},[59,504,505],{},"apparaît quand exactement un projet a été créé et l’ouvre",[41,507,508,513],{},[59,509,510],{},[19,511,512],{},"Rapport en CSV",[59,514,515],{},"télécharge un tableau avec nom du fichier, dossier, statut, chemin du projet, nombre de remarques et code d’erreur",[41,517,518,523],{},[59,519,520],{},[19,521,522],{},"Importer d’autres fichiers",[59,524,525],{},"démarre un nouvel import",[41,527,528,533],{},[59,529,530],{},[19,531,532],{},"Envoyer pour analyse",[59,534,535],{},"figure à côté d’un fichier non importé et le libère pour analyse (voir confidentialité)",[10,537,538],{},"Le rapport contient des codes et des chiffres. Il vous dit où regarder ; il ne confirme pas qu’un schéma est correct.",[10,540,541],{},[26,542],{"id":543},"scope",[30,545,547],{"id":546},"quest-ce-qui-est-repris-et-quest-ce-qui-ne-lest-pas","Qu’est-ce qui est repris, et qu’est-ce qui ne l’est pas ?",[35,549,550,563],{},[38,551,552],{},[41,553,554,557,560],{},[44,555,556],{},"Domaine",[44,558,559],{},"Repris",[44,561,562],{},"Non repris",[54,564,565,576,587,598,609,619,629,639,650],{},[41,566,567,570,573],{},[59,568,569],{},"Schéma unifilaire",[59,571,572],{},"alimentation, tableaux et sous-tableaux, interrupteur principal, appareils de protection, circuits avec protection et câbles, récepteurs",[59,574,575],{},"appareils sans protection de circuit propre et quelques configurations que Pro ne peut pas dessiner ; le rapport les nomme",[41,577,578,581,584],{},[59,579,580],{},"Combinaisons",[59,582,583],{},"adaptées dans Pro, p. ex. un disjoncteur suivi d’un interrupteur 30 mA devient un seul appareil combiné",[59,585,586],{},"–",[41,588,589,592,595],{},[59,590,591],{},"Valeurs",[59,593,594],{},"types de câbles, sections et calibres connus",[59,596,597],{},"les valeurs inconnues sont remplacées et les câbles marqués pour vérification",[41,599,600,603,606],{},[59,601,602],{},"Données du projet",[59,604,605],{},"client avec téléphone et GSM, adresse de l’installation, installateur, organisme agréé (nom, adresse)",[59,607,608],{},"téléphone et e-mail de l’organisme, date et révision, langue du document",[41,610,611,614,617],{},[59,612,613],{},"Notes",[59,615,616],{},"comme notes du schéma unifilaire, près du symbole ou libres sur la feuille, avec couleur et taille ; l’export peut les masquer",[59,618,586],{},[41,620,621,624,626],{},[59,622,623],{},"Mise en page",[59,625,586],{},[59,627,628],{},"lettres de circuit fixes (la lettre reste dans le nom du circuit), sauts de page manuels, affichage des sous-tableaux",[41,630,631,634,637],{},[59,632,633],{},"Câble d’alimentation",[59,635,636],{},"le câble en amont du compteur ou de l’interrupteur principal avec type, section, conducteurs, longueur et couleurs ; chaque sous-tableau avec son câble d’alimentation et son entrée (sans câble dans le fichier, Pro en crée un avec les valeurs par défaut et le rapport le signale)",[59,638,586],{},[41,640,641,644,647],{},[59,642,643],{},"Plan de position",[59,645,646],{},"un étage nommé par page, murs avec leur épaisseur, pièces nommées, portes avec sens d’ouverture, fenêtres, portes de garage, escaliers droits, textes libres (avec retours à la ligne) et rectangles, appareils placés (liés à leur circuit) ; type de pièce déduit du nom (p. ex. « Badkamer » → salle de bain, « Cuisine » → cuisine ; vide si le nom est peu clair, le rapport indique le nombre à vérifier) ; ordre des étages d’après des noms clairs (cave, rez-de-chaussée, étages, grenier), sinon dans l’ordre des pages",[59,648,649],{},"liaisons, symboles sans équivalent dans Pro, images de plans importés",[41,651,652,655,657],{},[59,653,654],{},"Impression",[59,656,586],{},[59,658,659],{},"logo (Pro imprime le logo de votre profil), options d’impression",[10,661,662],{},"Considérez comme non repris tout ce qui ne figure pas dans la colonne « Repris » ; le rapport de chaque fichier fait foi.",[10,664,665],{},[26,666],{"id":667},"duplicates",[30,669,671],{"id":670},"comment-planelec-reconnaît-il-les-doublons","Comment PlanElec reconnaît-il les doublons ?",[10,673,674,675,677],{},"PlanElec compare le contenu des fichiers au moyen d’une empreinte (SHA-256), pas le nom. Une copie renommée, un fichier présent deux fois dans le ZIP et un fichier d’un import précédent sont des doublons. La comparaison se fait dans la destination choisie, ",[19,676,324],{}," ou l’organisation, et uniquement avec des projets non archivés que vous avez le droit de voir.",[10,679,680],{},[26,681],{"id":682},"privacy",[30,684,686],{"id":685},"que-deviennent-mes-originaux","Que deviennent mes originaux ?",[35,688,689,699],{},[38,690,691],{},[41,692,693,696],{},[44,694,695],{},"Fichier",[44,697,698],{},"Conservation",[54,700,701,713,723,733],{},[41,702,703,706],{},[59,704,705],{},"Projet créé",[59,707,708,709,712],{},"L’original est conservé comme fichier de projet dans les ",[19,710,711],{},"Pièces du projet"," et reste tant que le projet existe. La copie utilisée pour le traitement est supprimée.",[41,714,715,720],{},[59,716,717,718],{},"Fichier non importé, consentement désactivé et pas de clic sur ",[19,719,532],{},[59,721,722],{},"L’original est supprimé après 30 jours.",[41,724,725,730],{},[59,726,727,728],{},"Fichier non importé, avec le consentement ou après ",[19,729,532],{},[59,731,732],{},"L’original est conservé jusqu’à 12 mois pour analyse, afin d’améliorer l’import pour de tels fichiers. Le résultat pour votre propre fichier ne change pas.",[41,734,735,738],{},[59,736,737],{},"Doublon ou fichier annulé",[59,739,740],{},"Non conservé ; PlanElec supprime les restes après un jour.",[10,742,743],{},"PlanElec supprime la liste des fichiers d’un import (noms, dossiers) 12 mois après sa fin. Vos fichiers sur votre ordinateur sont seulement lus, jamais modifiés. Les statistiques d’utilisation de l’import contiennent des chiffres et des codes, pas de noms de fichiers.",[10,745,746],{},[26,747],{"id":748},"sketch",[30,750,752],{"id":751},"comment-ouvrir-un-fichier-isolé-dans-sketch-et-le-reprendre-dans-pro","Comment ouvrir un fichier isolé dans Sketch et le reprendre dans Pro ?",[10,754,755,756,759,760,763,764,766],{},"PlanElec Sketch est la voie sans compte. Ouvrez le fichier via ",[19,757,758],{},"Document → Ouvrir"," ou depuis la page d’accueil (« Ouvrir un fichier Trikker (.trik) »), lisez le rapport d’import et continuez à travailler sur le schéma unifilaire. Ensuite, Sketch affiche le conseil « Transférer toute votre archive Trikker ? » avec le bouton ",[19,761,762],{},"Vers PlanElec Pro",". Si vous voulez poursuivre la planification dans Pro, choisissez ",[19,765,104],{},". Le plan de position suit : étages, murs, pièces, ouvertures, escaliers, textes, rectangles et appareils placés figurent ensuite sur le plan de Pro. Sketch ouvre des fichiers jusqu’à 8 Mo.",[30,768,770],{"id":769},"questions-fréquentes","Questions fréquentes",[390,772,774],{"id":773},"ai-je-besoin-dun-abonnement-pro","Ai-je besoin d’un abonnement Pro ?",[10,776,777],{},"Non. L’import est ouvert à tout compte connecté, y compris avec « Essayer Pro ». Les fonctions Pro que vous utilisez ensuite dans le projet dépendent de votre formule.",[390,779,781],{"id":780},"trikker-doit-il-être-installé","Trikker doit-il être installé ?",[10,783,784],{},"Non. L’import lit le contenu des fichiers.",[390,786,788],{"id":787},"puis-je-importer-un-pdf-trikker","Puis-je importer un PDF Trikker ?",[10,790,791,792,794,795,798],{},"Pas avec ",[19,793,69],{},". Pour un PDF contenant le plan, utilisez la ",[26,796,797],{"href":123},"reconnaissance de plan"," ou placez-le comme modèle.",[390,800,802],{"id":801},"que-se-passe-t-il-si-jinterromps-un-import","Que se passe-t-il si j’interromps un import ?",[10,804,805],{},"Si l’envoi reste à l’arrêt plus de 30 minutes, PlanElec clôt l’import. Les fichiers non arrivés figurent dans le rapport comme non importés. Relancez-les ensuite ; les projets déjà créés sont ignorés comme doublons.",[390,807,809],{"id":808},"un-projet-importé-est-il-vérifié","Un projet importé est-il vérifié ?",[10,811,812],{},"Non. C’est un point de départ. Comparez quelques projets à l’original, lisez les remarques et lancez l’autocontrôle dans Pro. Il montre les points ouverts et n’est pas une attestation ; le contrôle est effectué par l’organisme agréé.",[10,814,815,816,820],{},"Pour le contexte et la migration d’une archive entière, voyez l’article de blog ",[26,817,819],{"href":818},"\u002Ffr\u002Fblog\u002Fmigrer-archives-trikker","Migrer vos archives Trikker vers PlanElec Pro",". Trikker est une marque de son titulaire ; PlanElec n’utilise ce nom que pour désigner le produit.",{"title":822,"searchDepth":823,"depth":823,"links":824},"",2,[825,826,827,828,832,833,834,835,836,837],{"id":32,"depth":823,"text":33},{"id":146,"depth":823,"text":147},{"id":183,"depth":823,"text":184},{"id":258,"depth":823,"text":259,"children":829},[830],{"id":392,"depth":831,"text":393},3,{"id":468,"depth":823,"text":469},{"id":546,"depth":823,"text":547},{"id":670,"depth":823,"text":671},{"id":685,"depth":823,"text":686},{"id":751,"depth":823,"text":752},{"id":769,"depth":823,"text":770,"children":838},[839,840,841,842,843],{"id":773,"depth":831,"text":774},{"id":780,"depth":831,"text":781},{"id":787,"depth":831,"text":788},{"id":801,"depth":831,"text":802},{"id":808,"depth":831,"text":809},"getting_started","Importez des fichiers Trikker (.trik) dans PlanElec Pro un par un ou en archive : point d’entrée, choix des fichiers ou du ZIP, aperçu, destination, progression avec e-mail, rapport. Avec les limites, ce qui est repris ou non, et Sketch et l’import de plan comme alternatives.","md","trikker-import","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Ftrikker-import.webp","fr",{},true,19,"\u002Fhelp\u002Ftrikker-import.fr","2026-10-30","9 min",{"title":5,"description":845},null,"importer-des-projets-trikker","help\u002Ftrikker-import.fr",[861,16,862,863,864,865,866],"Trikker","import","import en lot","archive","ZIP","migration","2026-11-01","wH0eGozjBfGXIUyZePdfIpzWoyRIqBmEjpBnfTzpR8A",[870,1693,2510,3098],{"id":871,"title":872,"body":873,"category":844,"description":1679,"extension":846,"guideId":847,"image":848,"locale":1680,"meta":1681,"navigation":851,"order":852,"path":1682,"publishedAt":854,"readTime":1683,"seo":1684,"seoTitle":857,"slug":1685,"stem":1686,"tags":1687,"updatedAt":867,"__hash__":1692},"help\u002Fhelp\u002Ftrikker-import.de.md","Wie importiere ich meine Trikker-Projekte in PlanElec?",{"type":7,"value":874,"toc":1659},[875,885,889,893,981,993,997,1001,1027,1031,1035,1093,1099,1103,1107,1227,1234,1238,1305,1309,1313,1316,1379,1382,1386,1390,1501,1504,1508,1512,1518,1522,1526,1580,1583,1587,1591,1605,1609,1613,1616,1620,1623,1627,1637,1641,1644,1648,1651],[10,876,877,878,880,881,884],{},"Ein Trikker-Projekt ist eine ",[14,879,16],{},"-Datei. ",[19,882,883],{},"Du importierst sie in PlanElec Pro mit dem Eintrag „Trikker-Projekte importieren“: eine einzelne Datei genauso wie mehrere Dateien, einen Ordner oder ein ZIP-Archiv mit bis zu 500 Dateien."," Jede Datei wird ein eigenes Projekt, das Original bleibt als Datei am Projekt. Übernommen werden Eindrahtschema, Verteiler, Stromkreise und Geräte; der Positionsplan bleibt zurück. Du brauchst dafür ein angemeldetes PlanElec-Konto; ein Pro-Abonnement ist nicht nötig, „Pro testen“ genügt. Ohne Konto öffnest du eine einzelne Datei in PlanElec Sketch.",[10,886,887],{},[26,888],{"id":28},[30,890,892],{"id":891},"welcher-weg-passt-zu-meinen-daten","Welcher Weg passt zu meinen Daten?",[35,894,895,908],{},[38,896,897],{},[41,898,899,902,905],{},[44,900,901],{},"Du hast …",[44,903,904],{},"Dein Weg",[44,906,907],{},"Konto",[54,909,910,927,946,962],{},[41,911,912,918,924],{},[59,913,914,915,917],{},"ein Archiv aus vielen ",[14,916,16],{},"-Dateien, einen Ordner oder ein ZIP",[59,919,920,923],{},[19,921,922],{},"Trikker-Projekte importieren"," in PlanElec Pro (Hauptweg, siehe unten)",[59,925,926],{},"PlanElec-Konto",[41,928,929,935,944],{},[59,930,931,932,934],{},"eine einzelne ",[14,933,16],{},"-Datei",[59,936,937,938,940,941],{},"derselbe Weg: ",[19,939,922],{},"; bei genau einem Projekt bietet der Bericht ",[19,942,943],{},"Projekt öffnen",[59,945,926],{},[41,947,948,953,959],{},[59,949,931,950,952],{},[14,951,16],{},"-Datei und kein Konto",[59,954,955,956],{},"PlanElec Sketch: Datei öffnen, Schema prüfen, bei Bedarf ",[19,957,958],{},"In Pro übernehmen",[59,960,961],{},"keins für Sketch",[41,963,964,967,979],{},[59,965,966],{},"einen Grundriss als PDF, Scan, Bild oder DXF",[59,968,969,970,974,975],{},"Grundriss importieren oder erkennen lassen, siehe ",[26,971,973],{"href":972},"\u002Fde\u002Fhelp\u002Fgrundriss-importieren-und-kalibrieren","Grundriss importieren und kalibrieren"," und ",[26,976,978],{"href":977},"\u002Fde\u002Fhelp\u002Fgrundriss-mit-ki-erkennen","Grundriss mit KI erkennen",[59,980,926],{},[10,982,983,984,986,987,989,990,992],{},"Unsere Empfehlung: Importiere ",[14,985,16],{},"-Dateien über ",[19,988,922],{},". Das ist der eine Importpfad in Pro; er legt Projekte im Konto an und bewahrt das Original. Den Positionsplan der ",[14,991,16],{},"-Datei übernimmt er in den Grundriss: Etagen, Wände, Räume, Türen, Fenster, Garagentore, Treppen und platzierte Geräte.",[10,994,995],{},[26,996],{"id":143},[30,998,1000],{"id":999},"was-brauchst-du-für-den-import","Was brauchst du für den Import?",[149,1002,1003,1009,1021],{},[152,1004,1005,1008],{},[19,1006,1007],{},"Ein angemeldetes PlanElec-Konto."," Der Import steht jedem angemeldeten Konto offen, auch mit „Pro testen“.",[152,1010,1011,1017,1018,1020],{},[19,1012,1013,1014,1016],{},"Deine ",[14,1015,16],{},"-Dateien"," auf dem Rechner, an dem du arbeitest. Die automatischen Sicherungen von Trikker (",[14,1019,168],{},") sind keine Projektdateien; lass sie weg.",[152,1022,1023,1026],{},[19,1024,1025],{},"Einen Browser."," Er liest die Auswahl, entpackt ein ZIP und lädt jede Datei hoch. Danach läuft alles auf dem Server.",[10,1028,1029],{},[26,1030],{"id":180},[30,1032,1034],{"id":1033},"welche-grenzen-gelten","Welche Grenzen gelten?",[35,1036,1037,1047],{},[38,1038,1039],{},[41,1040,1041,1044],{},[44,1042,1043],{},"Grenze",[44,1045,1046],{},"Wert",[54,1048,1049,1059,1067,1077,1085],{},[41,1050,1051,1054],{},[59,1052,1053],{},"Dateien je Durchgang",[59,1055,1056,1057,1016],{},"bis zu 500 ",[14,1058,16],{},[41,1060,1061,1064],{},[59,1062,1063],{},"ZIP-Archiv",[59,1065,1066],{},"bis zu 200 MB",[41,1068,1069,1074],{},[59,1070,1071,1072,934],{},"Eine entpackte ",[14,1073,16],{},[59,1075,1076],{},"bis zu 5 MB",[41,1078,1079,1082],{},[59,1080,1081],{},"Alle entpackten Dateien zusammen",[59,1083,1084],{},"bis zu 500 MB",[41,1086,1087,1090],{},[59,1088,1089],{},"Gleichzeitige Durchgänge",[59,1091,1092],{},"ein Durchgang je Konto; ein zweiter startet erst, wenn der erste abgeschlossen oder abgebrochen ist",[10,1094,1095,1096,1098],{},"Versteckte Dateien und Ordner wie ",[14,1097,249],{}," sowie ein ZIP in einem ZIP werden übersprungen. Ist dein Archiv größer, teilst du es auf und importierst in mehreren Durchgängen. Dubletten werden erkannt, eine Überschneidung schadet nicht.",[10,1100,1101],{},[26,1102],{"id":255},[30,1104,1106],{"id":1105},"wie-läuft-der-import-schritt-für-schritt","Wie läuft der Import Schritt für Schritt?",[261,1108,1109,1126,1144,1158,1172,1181,1191,1197,1215,1221],{},[152,1110,1111,1114,1115,1117,1118,1121,1122,1125],{},[19,1112,1113],{},"Öffne den Import."," Du findest ",[19,1116,922],{}," an drei Stellen: im Logo-Menü eines Projekts (mit dem Badge ",[19,1119,1120],{},"Neu","), in der Projektliste neben ",[19,1123,1124],{},"Neues Projekt"," und in der Befehlspalette. Alle öffnen dieselbe Seite.",[152,1127,1128,1131,1132,1135,1136,1139,1140,1143],{},[19,1129,1130],{},"Wähle deine Dateien."," Ziehe Dateien, einen Ordner oder ein ZIP auf ",[19,1133,1134],{},"Dateien, Ordner oder ZIP hierher ziehen",", oder nutze ",[19,1137,1138],{},"Dateien wählen"," bzw. ",[19,1141,1142],{},"Ordner wählen",". Unterordner werden gelesen; der Ordnerpfad jeder Datei wird festgehalten.",[152,1145,1146,1149,1150,1153,1154,1157],{},[19,1147,1148],{},"Prüfe die Vorschau."," Die Liste zeigt ",[19,1151,1152],{},"50 Dateien geprüft"," und je Datei einen Status (Tabelle unten). Es ist noch nichts angelegt. Öffne die Details einer Datei mit Hinweisen und lies, was nicht übernommen wird. Mit ",[19,1155,1156],{},"Auswahl leeren"," beginnst du neu.",[152,1159,1160,1163,1164,1167,1168,1171],{},[19,1161,1162],{},"Wähle das Ziel."," Unter ",[19,1165,1166],{},"Anlegen in"," stehen ",[19,1169,1170],{},"Meine Projekte"," und die Organisationen, denen du angehörst.",[152,1173,1174,331,1177,1180],{},[19,1175,1176],{},"Entscheide über die Einwilligung.",[19,1178,1179],{},"Dateien zur Verbesserung des Imports nutzen"," ist freiwillig und standardmäßig aus (siehe Datenschutz).",[152,1182,1183,1186,1187,1190],{},[19,1184,1185],{},"Starte."," Der Knopf heißt ",[19,1188,1189],{},"48 Projekte anlegen",". Dubletten und Fehler werden übersprungen.",[152,1192,1193,1196],{},[19,1194,1195],{},"Warte, bis die Dateien hochgeladen sind."," Dann erscheint der Hinweis „Alle Dateien sind hochgeladen. Du kannst dieses Fenster schließen: Wir schicken dir eine E-Mail, sobald alles fertig ist.“ Bis dahin bleibt das Fenster offen.",[152,1198,1199,1202,1203,1206,1207,1210,1211,1214],{},[19,1200,1201],{},"Verfolge den Fortschritt oder schließe das Fenster."," Die Seite ",[19,1204,1205],{},"Deine Trikker-Projekte werden angelegt"," zeigt den Stand, die geschätzte Restzeit und unter ",[19,1208,1209],{},"Bisher erkannt"," Kennzahlen wie Stromkreise, Schutzschalter, Steckdosen, Lichtpunkte und Verteiler. Bereits angelegte Projekte findest du schon jetzt in der Projektübersicht. ",[19,1212,1213],{},"Rest abbrechen"," stoppt den Durchgang; fertige Projekte bleiben.",[152,1216,1217,1220],{},[19,1218,1219],{},"Lies die E-Mail."," Sobald jede Datei einen Endzustand hat, schickt PlanElec genau eine E-Mail an dein Konto, in der Sprache des Durchgangs, mit Zahlen und einem Link zum Bericht. Dateinamen und Kundennamen stehen nicht darin.",[152,1222,1223,1226],{},[19,1224,1225],{},"Öffne den Bericht."," Siehe nächster Abschnitt.",[10,1228,1229,1230,1233],{},"Erfolgskriterium: Der Bericht trägt den Titel ",[19,1231,1232],{},"48 Projekte angelegt",", und die Projekte erscheinen in der gewählten Projektliste.",[390,1235,1237],{"id":1236},"welche-status-zeigt-die-vorschau","Welche Status zeigt die Vorschau?",[35,1239,1240,1253],{},[38,1241,1242],{},[41,1243,1244,1247,1250],{},[44,1245,1246],{},"Status",[44,1248,1249],{},"Bedeutung",[44,1251,1252],{},"Was passiert beim Start",[54,1254,1255,1268,1280,1293],{},[41,1256,1257,1262,1265],{},[59,1258,1259],{},[19,1260,1261],{},"Bereit",[59,1263,1264],{},"Die Datei lässt sich lesen.",[59,1266,1267],{},"Es wird ein Projekt angelegt.",[41,1269,1270,1275,1278],{},[59,1271,1272],{},[19,1273,1274],{},"mit Hinweisen",[59,1276,1277],{},"Die Datei lässt sich lesen, Teile werden angepasst oder nicht übernommen. Die Details nennen sie.",[59,1279,1267],{},[41,1281,1282,1287,1290],{},[59,1283,1284],{},[19,1285,1286],{},"Dublette",[59,1288,1289],{},"Dieselbe Datei (gleicher Inhalt, nicht gleicher Name) ist im gewählten Bereich schon importiert oder liegt im Durchgang doppelt vor.",[59,1291,1292],{},"Wird übersprungen.",[41,1294,1295,1300,1303],{},[59,1296,1297],{},[19,1298,1299],{},"Fehler",[59,1301,1302],{},"Die Datei ist keine lesbare Trikker-Datei.",[59,1304,1292],{},[10,1306,1307],{},[26,1308],{"id":465},[30,1310,1312],{"id":1311},"was-zeigt-der-bericht","Was zeigt der Bericht?",[10,1314,1315],{},"Der Bericht öffnet sich über den Link der E-Mail oder, wenn du zurückkehrst, auf derselben Seite. Er nennt die Zahl der angelegten Projekte, getrennt nach ohne Hinweise, mit Hinweisen, übersprungene Dubletten und nicht importierte Dateien.",[35,1317,1318,1328],{},[38,1319,1320],{},[41,1321,1322,1325],{},[44,1323,1324],{},"Knopf",[44,1326,1327],{},"Wirkung",[54,1329,1330,1340,1349,1359,1369],{},[41,1331,1332,1337],{},[59,1333,1334],{},[19,1335,1336],{},"Projekte ansehen",[59,1338,1339],{},"öffnet die Projektliste mit den neuen Projekten",[41,1341,1342,1346],{},[59,1343,1344],{},[19,1345,943],{},[59,1347,1348],{},"erscheint, wenn genau ein Projekt angelegt wurde, und öffnet es",[41,1350,1351,1356],{},[59,1352,1353],{},[19,1354,1355],{},"Bericht als CSV",[59,1357,1358],{},"lädt eine Tabelle mit Dateiname, Ordner, Status, Projektpfad, Anzahl Hinweise und Fehlercode",[41,1360,1361,1366],{},[59,1362,1363],{},[19,1364,1365],{},"Weitere Dateien importieren",[59,1367,1368],{},"beginnt einen neuen Durchgang",[41,1370,1371,1376],{},[59,1372,1373],{},[19,1374,1375],{},"Zur Analyse senden",[59,1377,1378],{},"steht bei einer nicht importierten Datei und gibt sie zur Analyse frei (siehe Datenschutz)",[10,1380,1381],{},"Der Bericht enthält Codes und Zahlen. Er sagt dir, wo du hinsehen sollst, und bestätigt nicht, dass ein Schema stimmt.",[10,1383,1384],{},[26,1385],{"id":543},[30,1387,1389],{"id":1388},"was-wird-übernommen-und-was-nicht","Was wird übernommen und was nicht?",[35,1391,1392,1405],{},[38,1393,1394],{},[41,1395,1396,1399,1402],{},[44,1397,1398],{},"Bereich",[44,1400,1401],{},"Übernommen",[44,1403,1404],{},"Nicht übernommen",[54,1406,1407,1418,1428,1439,1450,1460,1470,1480,1491],{},[41,1408,1409,1412,1415],{},[59,1410,1411],{},"Eindrahtschema",[59,1413,1414],{},"Einspeisung, Verteiler und Unterverteiler, Hauptschalter, Schutzorgane, Stromkreise mit Schutz und Kabeln, Verbraucher",[59,1416,1417],{},"Geräte ohne eigenen Leitungsschutz und einzelne Konstellationen, die Pro nicht zeichnen kann; der Bericht nennt sie",[41,1419,1420,1423,1426],{},[59,1421,1422],{},"Kombinationen",[59,1424,1425],{},"werden in Pro angepasst, z. B. Leitungsschutzschalter mit nachgeschaltetem 30-mA-Schalter als ein kombiniertes Gerät",[59,1427,586],{},[41,1429,1430,1433,1436],{},[59,1431,1432],{},"Werte",[59,1434,1435],{},"bekannte Kabeltypen, Querschnitte und Bemessungen",[59,1437,1438],{},"unbekannte Werte werden ersetzt, die Kabel zur Prüfung markiert",[41,1440,1441,1444,1447],{},[59,1442,1443],{},"Projektdaten",[59,1445,1446],{},"Kunde mit Telefon und Handy (Gsm), Anlagenadresse, Installateur, zugelassene Kontrollstelle (Name, Adresse)",[59,1448,1449],{},"Telefon und E-Mail der Kontrollstelle, Datum und Revision, Dokumentsprache",[41,1451,1452,1455,1458],{},[59,1453,1454],{},"Notizen",[59,1456,1457],{},"als Notizen im Eindrahtschema, am Symbol oder frei auf dem Blatt, mit Farbe und Größe; beim Export ausblendbar",[59,1459,586],{},[41,1461,1462,1465,1467],{},[59,1463,1464],{},"Layout",[59,1466,586],{},[59,1468,1469],{},"feste Kreisbuchstaben (der Buchstabe steht im Namen des Stromkreises), manuelle Seitenumbrüche, Anzeige der Unterverteiler",[41,1471,1472,1475,1478],{},[59,1473,1474],{},"Zuleitung",[59,1476,1477],{},"die Zuleitung vor Zähler bzw. Hauptschalter mit Kabelart, Querschnitt, Adern, Länge und Leiterfarben; jeder Unterverteiler mit eigener Zuleitung und Eingang (fehlt das Kabel, legt Pro es mit Vorgabewerten an, der Bericht nennt es)",[59,1479,586],{},[41,1481,1482,1485,1488],{},[59,1483,1484],{},"Positionsplan",[59,1486,1487],{},"je Seite eine Etage mit Namen, Wände mit Dicke, Räume mit Namen, Türen mit Anschlag, Fenster, Garagentore, gerade Treppen, freie Texte (mit Zeilenumbrüchen) und Rechtecke, platzierte Geräte (mit ihrem Stromkreis verknüpft); Raumart aus dem Raumnamen (z. B. „Salle de bain“ → Bad, „Keuken“ → Küche, bei unklaren Namen leer, der Bericht nennt die Zahl zum Prüfen); Etagenfolge aus eindeutigen Namen (Keller, Erdgeschoss, Obergeschosse, Dachgeschoss), sonst in der Reihenfolge der Seiten",[59,1489,1490],{},"Leitungen, Symbole ohne Gegenstück in Pro, Bilder importierter Grundrisse",[41,1492,1493,1496,1498],{},[59,1494,1495],{},"Druck",[59,1497,586],{},[59,1499,1500],{},"Logo (Pro druckt das Logo aus deinem Profil), Druckoptionen",[10,1502,1503],{},"Was nicht in der Spalte „Übernommen“ steht, behandle als nicht übernommen; maßgeblich ist der Bericht der jeweiligen Datei.",[10,1505,1506],{},[26,1507],{"id":667},[30,1509,1511],{"id":1510},"wie-erkennt-planelec-dubletten","Wie erkennt PlanElec Dubletten?",[10,1513,1514,1515,1517],{},"PlanElec vergleicht den Inhalt der Dateien über einen Fingerabdruck (SHA-256), nicht den Namen. Eine umbenannte Kopie, eine Datei, die zweimal im ZIP liegt, und eine Datei aus einem früheren Durchgang sind Dubletten. Verglichen wird im gewählten Bereich: in ",[19,1516,1170],{}," oder in der Organisation, und nur mit Projekten, die nicht archiviert sind und die du sehen darfst.",[10,1519,1520],{},[26,1521],{"id":682},[30,1523,1525],{"id":1524},"was-passiert-mit-meinen-originalen","Was passiert mit meinen Originalen?",[35,1527,1528,1538],{},[38,1529,1530],{},[41,1531,1532,1535],{},[44,1533,1534],{},"Datei",[44,1536,1537],{},"Aufbewahrung",[54,1539,1540,1552,1562,1572],{},[41,1541,1542,1545],{},[59,1543,1544],{},"Angelegtes Projekt",[59,1546,1547,1548,1551],{},"Das Original liegt als Projektdatei in den ",[19,1549,1550],{},"Unterlagen"," des Projekts und bleibt, solange das Projekt besteht. Die Kopie, die für die Verarbeitung diente, wird gelöscht.",[41,1553,1554,1559],{},[59,1555,1556,1557],{},"Nicht importierte Datei, Einwilligung aus und kein Klick auf ",[19,1558,1375],{},[59,1560,1561],{},"Das Original wird nach 30 Tagen gelöscht.",[41,1563,1564,1569],{},[59,1565,1566,1567],{},"Nicht importierte Datei mit Einwilligung oder nach ",[19,1568,1375],{},[59,1570,1571],{},"Das Original bleibt bis zu 12 Monate zur Analyse, damit der Import für solche Dateien besser wird. Das Ergebnis deiner eigenen Datei ändert sich dadurch nicht.",[41,1573,1574,1577],{},[59,1575,1576],{},"Dublette oder abgebrochene Datei",[59,1578,1579],{},"Wird nicht aufbewahrt; Reste löscht PlanElec nach einem Tag.",[10,1581,1582],{},"Die Liste der Dateien eines Durchgangs (Namen, Ordner) löscht PlanElec 12 Monate nach Abschluss. Deine Dateien auf dem Rechner werden nur gelesen, nie verändert. Die Nutzungsstatistik des Imports enthält Zahlen und Codes, keine Dateinamen.",[10,1584,1585],{},[26,1586],{"id":748},[30,1588,1590],{"id":1589},"wie-öffne-ich-eine-einzelne-datei-in-sketch-und-übernehme-sie-nach-pro","Wie öffne ich eine einzelne Datei in Sketch und übernehme sie nach Pro?",[10,1592,1593,1594,1597,1598,1601,1602,1604],{},"PlanElec Sketch ist der Weg ohne Konto. Öffne die Datei über ",[19,1595,1596],{},"Dokument → Öffnen"," oder über die Startseite („Trikker-Datei (.trik) öffnen“), lies den Importbericht und arbeite am Eindrahtschema weiter. Danach zeigt Sketch den Hinweis „Ganzes Trikker-Archiv umziehen?“ mit dem Knopf ",[19,1599,1600],{},"Zu PlanElec Pro",". Willst du die Zeichnung in Pro weiterplanen, wähle ",[19,1603,958],{},". Der Positionsplan kommt mit: Etagen, Wände, Räume, Öffnungen, Treppen, Texte, Rechtecke und platzierte Geräte stehen danach im Pro-Grundriss. Sketch öffnet Dateien bis 8 MB.",[30,1606,1608],{"id":1607},"häufige-fragen","Häufige Fragen",[390,1610,1612],{"id":1611},"brauche-ich-ein-pro-abonnement","Brauche ich ein Pro-Abonnement?",[10,1614,1615],{},"Nein. Der Import steht jedem angemeldeten Konto offen, auch mit „Pro testen“. Welche Pro-Funktionen du danach im Projekt nutzt, richtet sich nach deinem Tarif.",[390,1617,1619],{"id":1618},"muss-trikker-installiert-sein","Muss Trikker installiert sein?",[10,1621,1622],{},"Nein. Der Import liest den Inhalt der Dateien.",[390,1624,1626],{"id":1625},"kann-ich-ein-trikker-pdf-importieren","Kann ich ein Trikker-PDF importieren?",[10,1628,1629,1630,1632,1633,1636],{},"Nicht über ",[19,1631,922],{},". Ein PDF mit dem Grundriss lässt du von der ",[26,1634,1635],{"href":977},"Grundrisserkennung"," lesen oder legst es als Vorlage unter.",[390,1638,1640],{"id":1639},"was-passiert-wenn-ich-einen-durchgang-unterbreche","Was passiert, wenn ich einen Durchgang unterbreche?",[10,1642,1643],{},"Bleibt der Upload länger als 30 Minuten stehen, schließt PlanElec den Durchgang ab. Dateien, die nicht angekommen sind, stehen im Bericht als nicht importiert. Starte sie danach erneut; bereits angelegte Projekte werden als Dubletten übersprungen.",[390,1645,1647],{"id":1646},"ist-ein-importiertes-projekt-geprüft","Ist ein importiertes Projekt geprüft?",[10,1649,1650],{},"Nein. Es ist ein Ausgangspunkt. Vergleiche einige Projekte mit dem Original, lies die Hinweise und lass den Selbstcheck in Pro laufen. Er zeigt offene Punkte und ist keine Bescheinigung; die Abnahme führt die zugelassene Kontrollstelle durch.",[10,1652,1653,1654,1658],{},"Mehr zum Hintergrund und zum Umzug eines ganzen Archivs steht im Blogartikel ",[26,1655,1657],{"href":1656},"\u002Fde\u002Fblog\u002Ftrikker-archiv-umziehen","Trikker-Archiv nach PlanElec Pro umziehen",". Trikker ist eine Marke ihres Inhabers; PlanElec verwendet den Namen nur, um auf das Produkt zu verweisen.",{"title":822,"searchDepth":823,"depth":823,"links":1660},[1661,1662,1663,1664,1667,1668,1669,1670,1671,1672],{"id":891,"depth":823,"text":892},{"id":999,"depth":823,"text":1000},{"id":1033,"depth":823,"text":1034},{"id":1105,"depth":823,"text":1106,"children":1665},[1666],{"id":1236,"depth":831,"text":1237},{"id":1311,"depth":823,"text":1312},{"id":1388,"depth":823,"text":1389},{"id":1510,"depth":823,"text":1511},{"id":1524,"depth":823,"text":1525},{"id":1589,"depth":823,"text":1590},{"id":1607,"depth":823,"text":1608,"children":1673},[1674,1675,1676,1677,1678],{"id":1611,"depth":831,"text":1612},{"id":1618,"depth":831,"text":1619},{"id":1625,"depth":831,"text":1626},{"id":1639,"depth":831,"text":1640},{"id":1646,"depth":831,"text":1647},"Trikker-Dateien (.trik) einzeln oder als Archiv in PlanElec Pro importieren: Einstieg, Dateien oder ZIP wählen, Vorschau, Ziel, Fortschritt mit E-Mail, Bericht. Dazu die Grenzen, was übernommen wird und was nicht, sowie Sketch und Grundriss-Import als Alternativen.","de",{},"\u002Fhelp\u002Ftrikker-import.de","9 Min.",{"title":872,"description":1679},"trikker-projekte-importieren","help\u002Ftrikker-import.de",[861,16,1688,1689,1690,865,1691],"Import","Batch-Import","Archiv","Umzug","Mv5q2y17jm2NVOVwsmYQtjau5YJF5Yq2MXcKacnl6yY",{"id":1694,"title":1695,"body":1696,"category":844,"description":2500,"extension":846,"guideId":847,"image":848,"locale":2501,"meta":2502,"navigation":851,"order":852,"path":2503,"publishedAt":854,"readTime":855,"seo":2504,"seoTitle":857,"slug":2505,"stem":2506,"tags":2507,"updatedAt":867,"__hash__":2509},"help\u002Fhelp\u002Ftrikker-import.en.md","How do I import my Trikker projects into PlanElec?",{"type":7,"value":1697,"toc":2480},[1698,1708,1712,1716,1805,1817,1821,1825,1851,1855,1859,1917,1923,1927,1931,2051,2058,2062,2128,2132,2136,2139,2202,2205,2209,2213,2322,2325,2329,2333,2339,2343,2347,2401,2404,2408,2412,2426,2430,2434,2437,2441,2444,2448,2458,2462,2465,2469,2472],[10,1699,1700,1701,1703,1704,1707],{},"A Trikker project is a ",[14,1702,16],{}," file. ",[19,1705,1706],{},"You import it into PlanElec Pro with the entry \"Import Trikker projects\": a single file just like several files, a folder or a ZIP archive with up to 500 files."," Every file becomes its own project, and the original stays attached to the project as a file. The single-line diagram, boards, circuits and devices come along; the situation plan stays behind. You need a signed-in PlanElec account; a Pro subscription is not required, \"Try Pro\" (the free plan) is enough. Without an account, you open a single file in PlanElec Sketch.",[10,1709,1710],{},[26,1711],{"id":28},[30,1713,1715],{"id":1714},"which-route-fits-my-data","Which route fits my data?",[35,1717,1718,1731],{},[38,1719,1720],{},[41,1721,1722,1725,1728],{},[44,1723,1724],{},"You have …",[44,1726,1727],{},"Your route",[44,1729,1730],{},"Account",[54,1732,1733,1750,1769,1786],{},[41,1734,1735,1741,1747],{},[59,1736,1737,1738,1740],{},"an archive of many ",[14,1739,16],{}," files, a folder or a ZIP",[59,1742,1743,1746],{},[19,1744,1745],{},"Import Trikker projects"," in PlanElec Pro (main route, see below)",[59,1748,1749],{},"PlanElec account",[41,1751,1752,1758,1767],{},[59,1753,1754,1755,1757],{},"a single ",[14,1756,16],{}," file",[59,1759,1760,1761,1763,1764],{},"the same route: ",[19,1762,1745],{},"; with exactly one project, the report offers ",[19,1765,1766],{},"Open project",[59,1768,1749],{},[41,1770,1771,1776,1783],{},[59,1772,1754,1773,1775],{},[14,1774,16],{}," file and no account",[59,1777,1778,1779,1782],{},"PlanElec Sketch: open the file, check the diagram, then ",[19,1780,1781],{},"Take it to Pro"," if you want to",[59,1784,1785],{},"none for Sketch",[41,1787,1788,1791,1803],{},[59,1789,1790],{},"a floor plan as PDF, scan, image or DXF",[59,1792,1793,1794,1798,1799],{},"import it or have it recognised, see ",[26,1795,1797],{"href":1796},"\u002Fen\u002Fhelp\u002Fimport-and-calibrate-a-floor-plan","Import and calibrate a floor plan"," and ",[26,1800,1802],{"href":1801},"\u002Fen\u002Fhelp\u002Frecognise-a-floor-plan-with-ai","Recognise a floor plan with AI",[59,1804,1749],{},[10,1806,1807,1808,1810,1811,1813,1814,1816],{},"Our recommendation: import ",[14,1809,16],{}," files with ",[19,1812,1745],{},". It is the one import route in Pro; it creates projects in your account and keeps the original. It takes the situation plan of the ",[14,1815,16],{}," file into the floor plan: floors, walls, rooms, doors, windows, garage doors, stairs and placed devices.",[10,1818,1819],{},[26,1820],{"id":143},[30,1822,1824],{"id":1823},"what-do-you-need-for-the-import","What do you need for the import?",[149,1826,1827,1833,1845],{},[152,1828,1829,1832],{},[19,1830,1831],{},"A signed-in PlanElec account."," The import is open to every signed-in account, including the free plan \"Try Pro\".",[152,1834,1835,1841,1842,1844],{},[19,1836,1837,1838,1840],{},"Your ",[14,1839,16],{}," files"," on the computer you are working on. Trikker's automatic backups (",[14,1843,168],{},") are not project files; leave them out.",[152,1846,1847,1850],{},[19,1848,1849],{},"A browser."," It reads your selection, unpacks a ZIP and uploads each file. Everything after that runs on the server.",[10,1852,1853],{},[26,1854],{"id":180},[30,1856,1858],{"id":1857},"which-limits-apply","Which limits apply?",[35,1860,1861,1871],{},[38,1862,1863],{},[41,1864,1865,1868],{},[44,1866,1867],{},"Limit",[44,1869,1870],{},"Value",[54,1872,1873,1883,1891,1901,1909],{},[41,1874,1875,1878],{},[59,1876,1877],{},"Files per run",[59,1879,1880,1881,1840],{},"up to 500 ",[14,1882,16],{},[41,1884,1885,1888],{},[59,1886,1887],{},"ZIP archive",[59,1889,1890],{},"up to 200 MB",[41,1892,1893,1898],{},[59,1894,1895,1896,1757],{},"One unpacked ",[14,1897,16],{},[59,1899,1900],{},"up to 5 MB",[41,1902,1903,1906],{},[59,1904,1905],{},"All unpacked files together",[59,1907,1908],{},"up to 500 MB",[41,1910,1911,1914],{},[59,1912,1913],{},"Runs at the same time",[59,1915,1916],{},"one run per account; a second one starts only after the first is completed or cancelled",[10,1918,1919,1920,1922],{},"Hidden files and folders such as ",[14,1921,249],{},", and a ZIP inside a ZIP, are skipped. If your archive is larger, split it and import in several runs. Duplicates are recognised, so an overlap does no harm.",[10,1924,1925],{},[26,1926],{"id":255},[30,1928,1930],{"id":1929},"how-does-the-import-work-step-by-step","How does the import work step by step?",[261,1932,1933,1950,1968,1982,1996,2005,2015,2021,2039,2045],{},[152,1934,1935,1938,1939,1941,1942,1945,1946,1949],{},[19,1936,1937],{},"Open the import."," You find ",[19,1940,1745],{}," in three places: in the logo menu of a project (with the badge ",[19,1943,1944],{},"New","), in the project list next to ",[19,1947,1948],{},"New project",", and in the command palette. All of them open the same page.",[152,1951,1952,1955,1956,1959,1960,1963,1964,1967],{},[19,1953,1954],{},"Choose your files."," Drop files, a folder or a ZIP onto ",[19,1957,1958],{},"Drag files, a folder or a ZIP here",", or use ",[19,1961,1962],{},"Choose files"," or ",[19,1965,1966],{},"Choose folder",". Sub-folders are read; the folder path of each file is recorded.",[152,1969,1970,1973,1974,1977,1978,1981],{},[19,1971,1972],{},"Check the preview."," The list shows ",[19,1975,1976],{},"50 files checked"," and a status per file (table below). Nothing has been created yet. Open the details of a file with notes to read what is not carried over. ",[19,1979,1980],{},"Clear selection"," starts over.",[152,1983,1984,1987,1988,1991,1992,1995],{},[19,1985,1986],{},"Choose the destination."," Under ",[19,1989,1990],{},"Create in"," you find ",[19,1993,1994],{},"My projects"," and the organisations you belong to.",[152,1997,1998,331,2001,2004],{},[19,1999,2000],{},"Decide about the opt-in.",[19,2002,2003],{},"Use files to improve the import"," is optional and off by default (see privacy below).",[152,2006,2007,2010,2011,2014],{},[19,2008,2009],{},"Start."," The button reads ",[19,2012,2013],{},"Create 48 projects",". Duplicates and errors are skipped.",[152,2016,2017,2020],{},[19,2018,2019],{},"Wait until the files are uploaded."," Then the message \"All files are uploaded. You can close this window: we will email you once everything is done.\" appears. Until then, keep the window open.",[152,2022,2023,2026,2027,2030,2031,2034,2035,2038],{},[19,2024,2025],{},"Follow the progress or close the window."," The page ",[19,2028,2029],{},"Your Trikker projects are being created"," shows the status, the estimated remaining time and, under ",[19,2032,2033],{},"Recognised so far",", counters such as circuits, protective devices, sockets, light points and boards. Projects that are already created show up in your project overview right away. ",[19,2036,2037],{},"Cancel the rest"," stops the run; finished projects stay.",[152,2040,2041,2044],{},[19,2042,2043],{},"Read the e-mail."," Once every file has a final state, PlanElec sends exactly one e-mail to your account, in the language of the run, with numbers and a link to the report. It contains no file names or customer names.",[152,2046,2047,2050],{},[19,2048,2049],{},"Open the report."," See the next section.",[10,2052,2053,2054,2057],{},"Success criterion: the report is titled ",[19,2055,2056],{},"48 projects created",", and the projects appear in the project list you chose.",[390,2059,2061],{"id":2060},"which-statuses-does-the-preview-show","Which statuses does the preview show?",[35,2063,2064,2076],{},[38,2065,2066],{},[41,2067,2068,2070,2073],{},[44,2069,1246],{},[44,2071,2072],{},"Meaning",[44,2074,2075],{},"What happens on start",[54,2077,2078,2091,2103,2116],{},[41,2079,2080,2085,2088],{},[59,2081,2082],{},[19,2083,2084],{},"Ready",[59,2086,2087],{},"The file can be read.",[59,2089,2090],{},"A project is created.",[41,2092,2093,2098,2101],{},[59,2094,2095],{},[19,2096,2097],{},"with notes",[59,2099,2100],{},"The file can be read, but parts are adjusted or not carried over. The details name them.",[59,2102,2090],{},[41,2104,2105,2110,2113],{},[59,2106,2107],{},[19,2108,2109],{},"Duplicate",[59,2111,2112],{},"The same file (same content, not necessarily the same name) was already imported into the chosen destination, or appears twice in the run.",[59,2114,2115],{},"Skipped.",[41,2117,2118,2123,2126],{},[59,2119,2120],{},[19,2121,2122],{},"Error",[59,2124,2125],{},"The file is not a readable Trikker file.",[59,2127,2115],{},[10,2129,2130],{},[26,2131],{"id":465},[30,2133,2135],{"id":2134},"what-does-the-report-show","What does the report show?",[10,2137,2138],{},"The report opens through the link in the e-mail or, if you come back, on the same page. It gives the number of created projects, split into without notes, with notes, duplicates skipped and files not imported.",[35,2140,2141,2151],{},[38,2142,2143],{},[41,2144,2145,2148],{},[44,2146,2147],{},"Button",[44,2149,2150],{},"Effect",[54,2152,2153,2163,2172,2182,2192],{},[41,2154,2155,2160],{},[59,2156,2157],{},[19,2158,2159],{},"View projects",[59,2161,2162],{},"opens the project list with the new projects",[41,2164,2165,2169],{},[59,2166,2167],{},[19,2168,1766],{},[59,2170,2171],{},"appears when exactly one project was created and opens it",[41,2173,2174,2179],{},[59,2175,2176],{},[19,2177,2178],{},"Report as CSV",[59,2180,2181],{},"downloads a table with file name, folder, status, project path, number of notes and error code",[41,2183,2184,2189],{},[59,2185,2186],{},[19,2187,2188],{},"Import more files",[59,2190,2191],{},"starts a new run",[41,2193,2194,2199],{},[59,2195,2196],{},[19,2197,2198],{},"Send for analysis",[59,2200,2201],{},"appears next to a file that was not imported and releases it for analysis (see privacy)",[10,2203,2204],{},"The report contains codes and numbers. It tells you where to look; it does not confirm that a diagram is correct.",[10,2206,2207],{},[26,2208],{"id":543},[30,2210,2212],{"id":2211},"what-is-carried-over-and-what-is-not","What is carried over and what is not?",[35,2214,2215,2228],{},[38,2216,2217],{},[41,2218,2219,2222,2225],{},[44,2220,2221],{},"Area",[44,2223,2224],{},"Carried over",[44,2226,2227],{},"Not carried over",[54,2229,2230,2241,2251,2262,2273,2282,2291,2301,2312],{},[41,2231,2232,2235,2238],{},[59,2233,2234],{},"Single-line diagram",[59,2236,2237],{},"supply, boards and sub-boards, main switch, protective devices, circuits with protection and cables, consumers",[59,2239,2240],{},"devices without their own circuit protection and a few arrangements Pro cannot draw; the report names them",[41,2242,2243,2246,2249],{},[59,2244,2245],{},"Combinations",[59,2247,2248],{},"adjusted in Pro, e.g. a circuit breaker followed by a 30 mA device becomes one combined device",[59,2250,586],{},[41,2252,2253,2256,2259],{},[59,2254,2255],{},"Values",[59,2257,2258],{},"known cable types, cross-sections and ratings",[59,2260,2261],{},"unknown values are replaced and the cables marked for review",[41,2263,2264,2267,2270],{},[59,2265,2266],{},"Project data",[59,2268,2269],{},"customer with phone and mobile (Gsm), installation address, installer, approved inspection body (name, address)",[59,2271,2272],{},"phone and e-mail of the inspection body, date and revision, document language",[41,2274,2275,2277,2280],{},[59,2276,613],{},[59,2278,2279],{},"as notes in the single-line diagram, beside the symbol or free on the sheet, with colour and size; the export can leave them out",[59,2281,586],{},[41,2283,2284,2286,2288],{},[59,2285,1464],{},[59,2287,586],{},[59,2289,2290],{},"fixed circuit letters (the letter stays in the circuit name), manual page breaks, how sub-boards are displayed",[41,2292,2293,2296,2299],{},[59,2294,2295],{},"Supply cable",[59,2297,2298],{},"the supply cable in front of the meter or main switch with cable type, cross-section, cores, length and conductor colours; every sub-board with its own supply cable and entry (without a cable in the file, Pro adds one with default values and the report says so)",[59,2300,586],{},[41,2302,2303,2306,2309],{},[59,2304,2305],{},"Situation plan",[59,2307,2308],{},"one named floor per page, walls with their thickness, named rooms, doors with their swing, windows, garage doors, straight stairs, free texts (with line breaks) and rectangles, placed devices (linked to their circuit); room type from the room name (e.g. “Salle de bain” → bathroom, “Keuken” → kitchen; empty for unclear names, the report gives the number to check); floor order from clear names (cellar, ground floor, upper floors, attic), otherwise in the order of the pages",[59,2310,2311],{},"wires, symbols without a counterpart in Pro, images of imported floor plans",[41,2313,2314,2317,2319],{},[59,2315,2316],{},"Print",[59,2318,586],{},[59,2320,2321],{},"logo (Pro prints the logo from your profile), print options",[10,2323,2324],{},"Treat everything that is not in the \"Carried over\" column as not carried over; the report of each file is the authority.",[10,2326,2327],{},[26,2328],{"id":667},[30,2330,2332],{"id":2331},"how-does-planelec-recognise-duplicates","How does PlanElec recognise duplicates?",[10,2334,2335,2336,2338],{},"PlanElec compares the content of the files through a fingerprint (SHA-256), not the name. A renamed copy, a file that is in the ZIP twice and a file from an earlier run are duplicates. The comparison runs within the chosen destination, either ",[19,2337,1994],{}," or the organisation, and only against projects that are not archived and that you are allowed to see.",[10,2340,2341],{},[26,2342],{"id":682},[30,2344,2346],{"id":2345},"what-happens-to-my-originals","What happens to my originals?",[35,2348,2349,2359],{},[38,2350,2351],{},[41,2352,2353,2356],{},[44,2354,2355],{},"File",[44,2357,2358],{},"Retention",[54,2360,2361,2373,2383,2393],{},[41,2362,2363,2366],{},[59,2364,2365],{},"Created project",[59,2367,2368,2369,2372],{},"The original is stored as a project file in the ",[19,2370,2371],{},"Project files"," of the project and stays as long as the project exists. The temporary copy used for processing is deleted.",[41,2374,2375,2380],{},[59,2376,2377,2378],{},"File not imported, opt-in off and no click on ",[19,2379,2198],{},[59,2381,2382],{},"The original is deleted after 30 days.",[41,2384,2385,2390],{},[59,2386,2387,2388],{},"File not imported, with the opt-in or after ",[19,2389,2198],{},[59,2391,2392],{},"The original is kept for analysis for up to 12 months so that the import gets better for such files. The result for your own file does not change.",[41,2394,2395,2398],{},[59,2396,2397],{},"Duplicate or cancelled file",[59,2399,2400],{},"Not kept; PlanElec deletes leftovers after one day.",[10,2402,2403],{},"PlanElec deletes the list of files of a run (names, folders) 12 months after completion. Your files on your computer are only read, never changed. The usage statistics of the import contain numbers and codes, no file names.",[10,2405,2406],{},[26,2407],{"id":748},[30,2409,2411],{"id":2410},"how-do-i-open-a-single-file-in-sketch-and-take-it-to-pro","How do I open a single file in Sketch and take it to Pro?",[10,2413,2414,2415,2418,2419,2422,2423,2425],{},"PlanElec Sketch is the route without an account. Open the file through ",[19,2416,2417],{},"Document → Open"," or from the start page (\"Open Trikker file (.trik)\"), read the import report and carry on working on the single-line diagram. Afterwards Sketch shows the note \"Move your whole Trikker archive?\" with the button ",[19,2420,2421],{},"Go to PlanElec Pro",". If you want to carry on planning in Pro, choose ",[19,2424,1781],{},". The situation plan comes along: floors, walls, rooms, openings, stairs, texts, rectangles and placed devices are then on the Pro floor plan. Sketch opens files up to 8 MB.",[30,2427,2429],{"id":2428},"frequently-asked-questions","Frequently asked questions",[390,2431,2433],{"id":2432},"do-i-need-a-pro-subscription","Do I need a Pro subscription?",[10,2435,2436],{},"No. The import is open to every signed-in account, including \"Try Pro\". Which Pro features you can use in the project afterwards depends on your plan.",[390,2438,2440],{"id":2439},"does-trikker-need-to-be-installed","Does Trikker need to be installed?",[10,2442,2443],{},"No. The import reads the contents of the files.",[390,2445,2447],{"id":2446},"can-i-import-a-trikker-pdf","Can I import a Trikker PDF?",[10,2449,2450,2451,2453,2454,2457],{},"Not with ",[19,2452,1745],{},". For a PDF with the floor plan, use ",[26,2455,2456],{"href":1801},"floor plan recognition"," or place it as a template.",[390,2459,2461],{"id":2460},"what-happens-if-i-interrupt-a-run","What happens if I interrupt a run?",[10,2463,2464],{},"If the upload stands still for more than 30 minutes, PlanElec closes the run. Files that did not arrive appear in the report as not imported. Start them again afterwards; projects that were already created are skipped as duplicates.",[390,2466,2468],{"id":2467},"is-an-imported-project-checked","Is an imported project checked?",[10,2470,2471],{},"No. It is a starting point. Compare a few projects with the original, read the notes and run the self-check in Pro. It shows open points and is not a certificate; the inspection is carried out by the approved inspection body.",[10,2473,2474,2475,2479],{},"More on the background and on moving a whole archive is in the blog article ",[26,2476,2478],{"href":2477},"\u002Fen\u002Fblog\u002Fmigrate-trikker-archive","Move your Trikker archive to PlanElec Pro",". Trikker is a trademark of its owner; PlanElec uses the name only to refer to the product.",{"title":822,"searchDepth":823,"depth":823,"links":2481},[2482,2483,2484,2485,2488,2489,2490,2491,2492,2493],{"id":1714,"depth":823,"text":1715},{"id":1823,"depth":823,"text":1824},{"id":1857,"depth":823,"text":1858},{"id":1929,"depth":823,"text":1930,"children":2486},[2487],{"id":2060,"depth":831,"text":2061},{"id":2134,"depth":823,"text":2135},{"id":2211,"depth":823,"text":2212},{"id":2331,"depth":823,"text":2332},{"id":2345,"depth":823,"text":2346},{"id":2410,"depth":823,"text":2411},{"id":2428,"depth":823,"text":2429,"children":2494},[2495,2496,2497,2498,2499],{"id":2432,"depth":831,"text":2433},{"id":2439,"depth":831,"text":2440},{"id":2446,"depth":831,"text":2447},{"id":2460,"depth":831,"text":2461},{"id":2467,"depth":831,"text":2468},"Import Trikker files (.trik) into PlanElec Pro one at a time or as an archive: entry point, choosing files or a ZIP, preview, destination, progress with e-mail, report. Plus limits, what is and is not carried over, and Sketch and floor plan import as alternatives.","en",{},"\u002Fhelp\u002Ftrikker-import.en",{"title":1695,"description":2500},"import-trikker-projects","help\u002Ftrikker-import.en",[861,16,862,2508,864,865,866],"batch import","AMtNSoMIovWWFNutripxeVr6FvdgKM9E2B8FZjNzNeM",{"id":4,"title":5,"body":2511,"category":844,"description":845,"extension":846,"guideId":847,"image":848,"locale":849,"meta":3095,"navigation":851,"order":852,"path":853,"publishedAt":854,"readTime":855,"seo":3096,"seoTitle":857,"slug":858,"stem":859,"tags":3097,"updatedAt":867,"__hash__":868},{"type":7,"value":2512,"toc":3075},[2513,2519,2523,2525,2589,2597,2601,2603,2621,2625,2627,2673,2677,2681,2683,2755,2759,2761,2815,2819,2821,2823,2875,2877,2881,2883,2969,2971,2975,2977,2981,2985,2987,3029,3031,3035,3037,3045,3047,3049,3051,3053,3055,3057,3063,3065,3067,3069,3071],[10,2514,12,2515,17,2517,22],{},[14,2516,16],{},[19,2518,21],{},[10,2520,2521],{},[26,2522],{"id":28},[30,2524,33],{"id":32},[35,2526,2527,2537],{},[38,2528,2529],{},[41,2530,2531,2533,2535],{},[44,2532,46],{},[44,2534,49],{},[44,2536,52],{},[54,2538,2539,2551,2565,2577],{},[41,2540,2541,2545,2549],{},[59,2542,61,2543,64],{},[14,2544,16],{},[59,2546,2547,70],{},[19,2548,69],{},[59,2550,73],{},[41,2552,2553,2557,2563],{},[59,2554,78,2555],{},[14,2556,16],{},[59,2558,83,2559,86,2561],{},[19,2560,69],{},[19,2562,89],{},[59,2564,73],{},[41,2566,2567,2571,2575],{},[59,2568,78,2569,98],{},[14,2570,16],{},[59,2572,101,2573],{},[19,2574,104],{},[59,2576,107],{},[41,2578,2579,2581,2587],{},[59,2580,112],{},[59,2582,115,2583,120,2585],{},[26,2584,119],{"href":118},[26,2586,124],{"href":123},[59,2588,73],{},[10,2590,129,2591,132,2593,135,2595,138],{},[14,2592,16],{},[19,2594,69],{},[14,2596,16],{},[10,2598,2599],{},[26,2600],{"id":143},[30,2602,147],{"id":146},[149,2604,2605,2609,2617],{},[152,2606,2607,157],{},[19,2608,156],{},[152,2610,2611,165,2615,169],{},[19,2612,162,2613],{},[14,2614,16],{},[14,2616,168],{},[152,2618,2619,175],{},[19,2620,174],{},[10,2622,2623],{},[26,2624],{"id":180},[30,2626,184],{"id":183},[35,2628,2629,2637],{},[38,2630,2631],{},[41,2632,2633,2635],{},[44,2634,193],{},[44,2636,196],{},[54,2638,2639,2647,2653,2661,2667],{},[41,2640,2641,2643],{},[59,2642,203],{},[59,2644,206,2645],{},[14,2646,16],{},[41,2648,2649,2651],{},[59,2650,213],{},[59,2652,216],{},[41,2654,2655,2659],{},[59,2656,221,2657,224],{},[14,2658,16],{},[59,2660,227],{},[41,2662,2663,2665],{},[59,2664,232],{},[59,2666,235],{},[41,2668,2669,2671],{},[59,2670,240],{},[59,2672,243],{},[10,2674,246,2675,250],{},[14,2676,249],{},[10,2678,2679],{},[26,2680],{"id":255},[30,2682,259],{"id":258},[261,2684,2685,2695,2705,2713,2721,2727,2733,2737,2747,2751],{},[152,2686,2687,268,2689,271,2691,275,2693,279],{},[19,2688,267],{},[19,2690,69],{},[19,2692,274],{},[19,2694,278],{},[152,2696,2697,285,2699,289,2701,293,2703,297],{},[19,2698,284],{},[19,2700,288],{},[19,2702,292],{},[19,2704,296],{},[152,2706,2707,303,2709,307,2711,311],{},[19,2708,302],{},[19,2710,306],{},[19,2712,310],{},[152,2714,2715,317,2717,321,2719,325],{},[19,2716,316],{},[19,2718,320],{},[19,2720,324],{},[152,2722,2723,331,2725,335],{},[19,2724,330],{},[19,2726,334],{},[152,2728,2729,341,2731,345],{},[19,2730,340],{},[19,2732,344],{},[152,2734,2735,351],{},[19,2736,350],{},[152,2738,2739,357,2741,361,2743,365,2745,369],{},[19,2740,356],{},[19,2742,360],{},[19,2744,364],{},[19,2746,368],{},[152,2748,2749,375],{},[19,2750,374],{},[152,2752,2753,381],{},[19,2754,380],{},[10,2756,384,2757,388],{},[19,2758,387],{},[390,2760,393],{"id":392},[35,2762,2763,2773],{},[38,2764,2765],{},[41,2766,2767,2769,2771],{},[44,2768,402],{},[44,2770,405],{},[44,2772,408],{},[54,2774,2775,2785,2795,2805],{},[41,2776,2777,2781,2783],{},[59,2778,2779],{},[19,2780,417],{},[59,2782,420],{},[59,2784,423],{},[41,2786,2787,2791,2793],{},[59,2788,2789],{},[19,2790,430],{},[59,2792,433],{},[59,2794,423],{},[41,2796,2797,2801,2803],{},[59,2798,2799],{},[19,2800,442],{},[59,2802,445],{},[59,2804,448],{},[41,2806,2807,2811,2813],{},[59,2808,2809],{},[19,2810,455],{},[59,2812,458],{},[59,2814,448],{},[10,2816,2817],{},[26,2818],{"id":465},[30,2820,469],{"id":468},[10,2822,472],{},[35,2824,2825,2833],{},[38,2826,2827],{},[41,2828,2829,2831],{},[44,2830,481],{},[44,2832,484],{},[54,2834,2835,2843,2851,2859,2867],{},[41,2836,2837,2841],{},[59,2838,2839],{},[19,2840,493],{},[59,2842,496],{},[41,2844,2845,2849],{},[59,2846,2847],{},[19,2848,89],{},[59,2850,505],{},[41,2852,2853,2857],{},[59,2854,2855],{},[19,2856,512],{},[59,2858,515],{},[41,2860,2861,2865],{},[59,2862,2863],{},[19,2864,522],{},[59,2866,525],{},[41,2868,2869,2873],{},[59,2870,2871],{},[19,2872,532],{},[59,2874,535],{},[10,2876,538],{},[10,2878,2879],{},[26,2880],{"id":543},[30,2882,547],{"id":546},[35,2884,2885,2895],{},[38,2886,2887],{},[41,2888,2889,2891,2893],{},[44,2890,556],{},[44,2892,559],{},[44,2894,562],{},[54,2896,2897,2905,2913,2921,2929,2937,2945,2953,2961],{},[41,2898,2899,2901,2903],{},[59,2900,569],{},[59,2902,572],{},[59,2904,575],{},[41,2906,2907,2909,2911],{},[59,2908,580],{},[59,2910,583],{},[59,2912,586],{},[41,2914,2915,2917,2919],{},[59,2916,591],{},[59,2918,594],{},[59,2920,597],{},[41,2922,2923,2925,2927],{},[59,2924,602],{},[59,2926,605],{},[59,2928,608],{},[41,2930,2931,2933,2935],{},[59,2932,613],{},[59,2934,616],{},[59,2936,586],{},[41,2938,2939,2941,2943],{},[59,2940,623],{},[59,2942,586],{},[59,2944,628],{},[41,2946,2947,2949,2951],{},[59,2948,633],{},[59,2950,636],{},[59,2952,586],{},[41,2954,2955,2957,2959],{},[59,2956,643],{},[59,2958,646],{},[59,2960,649],{},[41,2962,2963,2965,2967],{},[59,2964,654],{},[59,2966,586],{},[59,2968,659],{},[10,2970,662],{},[10,2972,2973],{},[26,2974],{"id":667},[30,2976,671],{"id":670},[10,2978,674,2979,677],{},[19,2980,324],{},[10,2982,2983],{},[26,2984],{"id":682},[30,2986,686],{"id":685},[35,2988,2989,2997],{},[38,2990,2991],{},[41,2992,2993,2995],{},[44,2994,695],{},[44,2996,698],{},[54,2998,2999,3007,3015,3023],{},[41,3000,3001,3003],{},[59,3002,705],{},[59,3004,708,3005,712],{},[19,3006,711],{},[41,3008,3009,3013],{},[59,3010,717,3011],{},[19,3012,532],{},[59,3014,722],{},[41,3016,3017,3021],{},[59,3018,727,3019],{},[19,3020,532],{},[59,3022,732],{},[41,3024,3025,3027],{},[59,3026,737],{},[59,3028,740],{},[10,3030,743],{},[10,3032,3033],{},[26,3034],{"id":748},[30,3036,752],{"id":751},[10,3038,755,3039,759,3041,763,3043,766],{},[19,3040,758],{},[19,3042,762],{},[19,3044,104],{},[30,3046,770],{"id":769},[390,3048,774],{"id":773},[10,3050,777],{},[390,3052,781],{"id":780},[10,3054,784],{},[390,3056,788],{"id":787},[10,3058,791,3059,794,3061,798],{},[19,3060,69],{},[26,3062,797],{"href":123},[390,3064,802],{"id":801},[10,3066,805],{},[390,3068,809],{"id":808},[10,3070,812],{},[10,3072,815,3073,820],{},[26,3074,819],{"href":818},{"title":822,"searchDepth":823,"depth":823,"links":3076},[3077,3078,3079,3080,3083,3084,3085,3086,3087,3088],{"id":32,"depth":823,"text":33},{"id":146,"depth":823,"text":147},{"id":183,"depth":823,"text":184},{"id":258,"depth":823,"text":259,"children":3081},[3082],{"id":392,"depth":831,"text":393},{"id":468,"depth":823,"text":469},{"id":546,"depth":823,"text":547},{"id":670,"depth":823,"text":671},{"id":685,"depth":823,"text":686},{"id":751,"depth":823,"text":752},{"id":769,"depth":823,"text":770,"children":3089},[3090,3091,3092,3093,3094],{"id":773,"depth":831,"text":774},{"id":780,"depth":831,"text":781},{"id":787,"depth":831,"text":788},{"id":801,"depth":831,"text":802},{"id":808,"depth":831,"text":809},{},{"title":5,"description":845},[861,16,862,863,864,865,866],{"id":3099,"title":3100,"body":3101,"category":844,"description":3904,"extension":846,"guideId":847,"image":848,"locale":3905,"meta":3906,"navigation":851,"order":852,"path":3907,"publishedAt":854,"readTime":855,"seo":3908,"seoTitle":857,"slug":3909,"stem":3910,"tags":3911,"updatedAt":867,"__hash__":3915},"help\u002Fhelp\u002Ftrikker-import.nl.md","Hoe importeer ik mijn Trikker-projecten in PlanElec?",{"type":7,"value":3102,"toc":3884},[3103,3113,3117,3121,3208,3220,3224,3228,3254,3258,3262,3320,3326,3330,3334,3453,3460,3464,3530,3534,3538,3541,3604,3607,3611,3615,3726,3729,3733,3737,3743,3747,3751,3805,3808,3812,3816,3830,3834,3838,3841,3845,3848,3852,3862,3866,3869,3873,3876],[10,3104,3105,3106,3108,3109,3112],{},"Een Trikker-project is een ",[14,3107,16],{},"-bestand. ",[19,3110,3111],{},"Je importeert het in PlanElec Pro met de ingang \"Trikker-projecten importeren\": één bestand net zo goed als meerdere bestanden, een map of een ZIP-archief met maximaal 500 bestanden."," Elk bestand wordt een eigen project, het origineel blijft als bestand bij het project. Het eendraadschema, de verdeelborden, stroomkringen en toestellen komen mee; het situatieplan blijft achter. Je hebt een aangemeld PlanElec-account nodig; een Pro-abonnement is niet nodig, \"Pro uitproberen\" volstaat. Zonder account open je één bestand in PlanElec Sketch.",[10,3114,3115],{},[26,3116],{"id":28},[30,3118,3120],{"id":3119},"welke-weg-past-bij-mijn-gegevens","Welke weg past bij mijn gegevens?",[35,3122,3123,3135],{},[38,3124,3125],{},[41,3126,3127,3130,3133],{},[44,3128,3129],{},"Je hebt …",[44,3131,3132],{},"Jouw weg",[44,3134,1730],{},[54,3136,3137,3154,3173,3189],{},[41,3138,3139,3145,3151],{},[59,3140,3141,3142,3144],{},"een archief met veel ",[14,3143,16],{},"-bestanden, een map of een ZIP",[59,3146,3147,3150],{},[19,3148,3149],{},"Trikker-projecten importeren"," in PlanElec Pro (hoofdweg, zie hieronder)",[59,3152,3153],{},"PlanElec-account",[41,3155,3156,3162,3171],{},[59,3157,3158,3159,3161],{},"één enkel ",[14,3160,16],{},"-bestand",[59,3163,3164,3165,3167,3168],{},"dezelfde weg: ",[19,3166,3149],{},"; bij precies één project biedt het rapport ",[19,3169,3170],{},"Project openen",[59,3172,3153],{},[41,3174,3175,3180,3186],{},[59,3176,3158,3177,3179],{},[14,3178,16],{},"-bestand en geen account",[59,3181,3182,3183],{},"PlanElec Sketch: bestand openen, schema nakijken en eventueel ",[19,3184,3185],{},"Overnemen in Pro",[59,3187,3188],{},"geen voor Sketch",[41,3190,3191,3194,3206],{},[59,3192,3193],{},"een grondplan als PDF, scan, afbeelding of DXF",[59,3195,3196,3197,3201,3202],{},"importeren of laten herkennen, zie ",[26,3198,3200],{"href":3199},"\u002Fhelp\u002Fgrondplan-importeren-en-kalibreren","Grondplan importeren en kalibreren"," en ",[26,3203,3205],{"href":3204},"\u002Fhelp\u002Fgrondplan-herkennen-met-ai","Grondplan herkennen met AI",[59,3207,3153],{},[10,3209,3210,3211,3213,3214,3216,3217,3219],{},"Onze aanbeveling: importeer ",[14,3212,16],{},"-bestanden met ",[19,3215,3149],{},". Dat is de ene importweg in Pro; ze maakt projecten aan in je account en bewaart het origineel. Het situatieplan van het ",[14,3218,16],{},"-bestand komt mee in de grondplan: verdiepingen, muren, ruimtes, deuren, ramen, garagepoorten, trappen en geplaatste toestellen.",[10,3221,3222],{},[26,3223],{"id":143},[30,3225,3227],{"id":3226},"wat-heb-je-nodig-voor-de-import","Wat heb je nodig voor de import?",[149,3229,3230,3236,3248],{},[152,3231,3232,3235],{},[19,3233,3234],{},"Een aangemeld PlanElec-account."," De import staat open voor elk aangemeld account, ook met \"Pro uitproberen\".",[152,3237,3238,3244,3245,3247],{},[19,3239,3240,3241,3243],{},"Je ",[14,3242,16],{},"-bestanden"," op de computer waarop je werkt. De automatische back-ups van Trikker (",[14,3246,168],{},") zijn geen projectbestanden; laat ze weg.",[152,3249,3250,3253],{},[19,3251,3252],{},"Een browser."," Die leest je selectie, pakt een ZIP uit en laadt elk bestand op. Alles daarna loopt op de server.",[10,3255,3256],{},[26,3257],{"id":180},[30,3259,3261],{"id":3260},"welke-grenzen-gelden-er","Welke grenzen gelden er?",[35,3263,3264,3274],{},[38,3265,3266],{},[41,3267,3268,3271],{},[44,3269,3270],{},"Grens",[44,3272,3273],{},"Waarde",[54,3275,3276,3286,3294,3304,3312],{},[41,3277,3278,3281],{},[59,3279,3280],{},"Bestanden per keer",[59,3282,3283,3284,3243],{},"tot 500 ",[14,3285,16],{},[41,3287,3288,3291],{},[59,3289,3290],{},"ZIP-archief",[59,3292,3293],{},"tot 200 MB",[41,3295,3296,3301],{},[59,3297,3298,3299,3161],{},"Eén uitgepakt ",[14,3300,16],{},[59,3302,3303],{},"tot 5 MB",[41,3305,3306,3309],{},[59,3307,3308],{},"Alle uitgepakte bestanden samen",[59,3310,3311],{},"tot 500 MB",[41,3313,3314,3317],{},[59,3315,3316],{},"Gelijktijdige runs",[59,3318,3319],{},"één per account; een tweede start pas als de eerste is afgerond of geannuleerd",[10,3321,3322,3323,3325],{},"Verborgen bestanden en mappen zoals ",[14,3324,249],{}," en een ZIP in een ZIP worden overgeslagen. Is je archief groter, splits het dan op en importeer in meerdere runs. Duplicaten worden herkend, een overlap is dus geen probleem.",[10,3327,3328],{},[26,3329],{"id":255},[30,3331,3333],{"id":3332},"hoe-verloopt-de-import-stap-voor-stap","Hoe verloopt de import stap voor stap?",[261,3335,3336,3353,3371,3385,3399,3408,3417,3423,3441,3447],{},[152,3337,3338,3341,3342,3344,3345,3348,3349,3352],{},[19,3339,3340],{},"Open de import."," Je vindt ",[19,3343,3149],{}," op drie plaatsen: in het logomenu van een project (met de badge ",[19,3346,3347],{},"Nieuw","), in de projectlijst naast ",[19,3350,3351],{},"Nieuw project"," en in het opdrachtenpalet. Alle drie openen dezelfde pagina.",[152,3354,3355,3358,3359,3362,3363,3366,3367,3370],{},[19,3356,3357],{},"Kies je bestanden."," Sleep bestanden, een map of een ZIP naar ",[19,3360,3361],{},"Bestanden, map of ZIP hierheen slepen",", of gebruik ",[19,3364,3365],{},"Bestanden kiezen"," of ",[19,3368,3369],{},"Map kiezen",". Submappen worden gelezen; het mappad van elk bestand wordt bijgehouden.",[152,3372,3373,3376,3377,3380,3381,3384],{},[19,3374,3375],{},"Controleer de voorvertoning."," De lijst toont ",[19,3378,3379],{},"50 bestanden gecontroleerd"," en per bestand een status (tabel hieronder). Er is nog niets aangemaakt. Open de details van een bestand met opmerkingen om te lezen wat niet wordt overgenomen. Met ",[19,3382,3383],{},"Selectie wissen"," begin je opnieuw.",[152,3386,3387,3390,3391,3394,3395,3398],{},[19,3388,3389],{},"Kies de bestemming."," Onder ",[19,3392,3393],{},"Aanmaken in"," vind je ",[19,3396,3397],{},"Mijn projecten"," en de organisaties waartoe je behoort.",[152,3400,3401,331,3404,3407],{},[19,3402,3403],{},"Beslis over de toestemming.",[19,3405,3406],{},"Bestanden gebruiken om de import te verbeteren"," is vrijwillig en standaard uit (zie privacy hieronder).",[152,3409,3410,3412,3413,3416],{},[19,3411,2009],{}," De knop heet ",[19,3414,3415],{},"48 projecten aanmaken",". Duplicaten en fouten worden overgeslagen.",[152,3418,3419,3422],{},[19,3420,3421],{},"Wacht tot de bestanden zijn opgeladen."," Dan verschijnt de melding \"Alle bestanden zijn opgeladen. Je mag dit venster sluiten: we sturen je een e-mail zodra alles klaar is.\" Tot dan blijft het venster open.",[152,3424,3425,3428,3429,3432,3433,3436,3437,3440],{},[19,3426,3427],{},"Volg de voortgang of sluit het venster."," De pagina ",[19,3430,3431],{},"Je Trikker-projecten worden aangemaakt"," toont de stand, de geschatte resterende tijd en onder ",[19,3434,3435],{},"Tot nu toe herkend"," tellers zoals stroomkringen, beveiligingen, stopcontacten, lichtpunten en verdeelborden. Projecten die al klaar zijn, staan meteen in je projectoverzicht. ",[19,3438,3439],{},"Rest annuleren"," stopt de run; voltooide projecten blijven.",[152,3442,3443,3446],{},[19,3444,3445],{},"Lees de e-mail."," Zodra elk bestand een eindstatus heeft, stuurt PlanElec precies één e-mail naar je account, in de taal van de run, met cijfers en een link naar het rapport. Bestands- en klantnamen staan er niet in.",[152,3448,3449,3452],{},[19,3450,3451],{},"Open het rapport."," Zie de volgende sectie.",[10,3454,3455,3456,3459],{},"Succescriterium: het rapport heet ",[19,3457,3458],{},"48 projecten aangemaakt"," en de projecten staan in de gekozen projectlijst.",[390,3461,3463],{"id":3462},"welke-statussen-toont-de-voorvertoning","Welke statussen toont de voorvertoning?",[35,3465,3466,3478],{},[38,3467,3468],{},[41,3469,3470,3472,3475],{},[44,3471,1246],{},[44,3473,3474],{},"Betekenis",[44,3476,3477],{},"Wat gebeurt er bij de start",[54,3479,3480,3493,3505,3518],{},[41,3481,3482,3487,3490],{},[59,3483,3484],{},[19,3485,3486],{},"Klaar",[59,3488,3489],{},"Het bestand is leesbaar.",[59,3491,3492],{},"Er wordt een project aangemaakt.",[41,3494,3495,3500,3503],{},[59,3496,3497],{},[19,3498,3499],{},"met opmerkingen",[59,3501,3502],{},"Het bestand is leesbaar, maar onderdelen worden aangepast of niet overgenomen. De details noemen ze.",[59,3504,3492],{},[41,3506,3507,3512,3515],{},[59,3508,3509],{},[19,3510,3511],{},"Duplicaat",[59,3513,3514],{},"Hetzelfde bestand (zelfde inhoud, niet noodzakelijk dezelfde naam) werd al geïmporteerd in de gekozen bestemming of staat tweemaal in de run.",[59,3516,3517],{},"Wordt overgeslagen.",[41,3519,3520,3525,3528],{},[59,3521,3522],{},[19,3523,3524],{},"Fout",[59,3526,3527],{},"Het bestand is geen leesbaar Trikker-bestand.",[59,3529,3517],{},[10,3531,3532],{},[26,3533],{"id":465},[30,3535,3537],{"id":3536},"wat-toont-het-rapport","Wat toont het rapport?",[10,3539,3540],{},"Het rapport opent via de link in de e-mail of, als je terugkomt, op dezelfde pagina. Het noemt het aantal aangemaakte projecten, opgesplitst in zonder opmerkingen, met opmerkingen, overgeslagen duplicaten en niet-geïmporteerde bestanden.",[35,3542,3543,3553],{},[38,3544,3545],{},[41,3546,3547,3550],{},[44,3548,3549],{},"Knop",[44,3551,3552],{},"Werking",[54,3554,3555,3565,3574,3584,3594],{},[41,3556,3557,3562],{},[59,3558,3559],{},[19,3560,3561],{},"Projecten bekijken",[59,3563,3564],{},"opent de projectlijst met de nieuwe projecten",[41,3566,3567,3571],{},[59,3568,3569],{},[19,3570,3170],{},[59,3572,3573],{},"verschijnt als precies één project is aangemaakt en opent het",[41,3575,3576,3581],{},[59,3577,3578],{},[19,3579,3580],{},"Rapport als CSV",[59,3582,3583],{},"downloadt een tabel met bestandsnaam, map, status, projectpad, aantal opmerkingen en foutcode",[41,3585,3586,3591],{},[59,3587,3588],{},[19,3589,3590],{},"Meer bestanden importeren",[59,3592,3593],{},"start een nieuwe run",[41,3595,3596,3601],{},[59,3597,3598],{},[19,3599,3600],{},"Ter analyse versturen",[59,3602,3603],{},"staat bij een niet-geïmporteerd bestand en geeft het vrij voor analyse (zie privacy)",[10,3605,3606],{},"Het rapport bevat codes en cijfers. Het zegt je waar je moet kijken en bevestigt niet dat een schema klopt.",[10,3608,3609],{},[26,3610],{"id":543},[30,3612,3614],{"id":3613},"wat-wordt-overgenomen-en-wat-niet","Wat wordt overgenomen en wat niet?",[35,3616,3617,3630],{},[38,3618,3619],{},[41,3620,3621,3624,3627],{},[44,3622,3623],{},"Onderdeel",[44,3625,3626],{},"Overgenomen",[44,3628,3629],{},"Niet overgenomen",[54,3631,3632,3643,3653,3664,3675,3685,3695,3705,3716],{},[41,3633,3634,3637,3640],{},[59,3635,3636],{},"Eendraadschema",[59,3638,3639],{},"voeding, verdeelborden en onderverdelers, hoofdschakelaar, beveiligingen, stroomkringen met beveiliging en kabels, verbruikers",[59,3641,3642],{},"toestellen zonder eigen kringbeveiliging en enkele opstellingen die Pro niet kan tekenen; het rapport noemt ze",[41,3644,3645,3648,3651],{},[59,3646,3647],{},"Combinaties",[59,3649,3650],{},"aangepast in Pro, bv. een automaat met een 30 mA-schakelaar erachter wordt één gecombineerd toestel",[59,3652,586],{},[41,3654,3655,3658,3661],{},[59,3656,3657],{},"Waarden",[59,3659,3660],{},"bekende kabeltypes, doorsneden en nominale waarden",[59,3662,3663],{},"onbekende waarden worden vervangen en de kabels gemarkeerd voor nazicht",[41,3665,3666,3669,3672],{},[59,3667,3668],{},"Projectgegevens",[59,3670,3671],{},"klant met telefoon en gsm, adres van de installatie, installateur, erkend organisme (naam, adres)",[59,3673,3674],{},"telefoon en e-mail van het organisme, datum en revisie, documenttaal",[41,3676,3677,3680,3683],{},[59,3678,3679],{},"Notities",[59,3681,3682],{},"als notities in het eendraadschema, bij het symbool of vrij op het blad, met kleur en grootte; bij het exporteren te verbergen",[59,3684,586],{},[41,3686,3687,3690,3692],{},[59,3688,3689],{},"Opmaak",[59,3691,586],{},[59,3693,3694],{},"vaste kringletters (de letter blijft in de kringnaam), handmatige pagina-einden, weergave van onderverdelers",[41,3696,3697,3700,3703],{},[59,3698,3699],{},"Voedingskabel",[59,3701,3702],{},"de voedingskabel vóór de meter of hoofdschakelaar met kabeltype, doorsnede, aders, lengte en aderkleuren; elke onderverdeling met eigen voedingskabel en ingang (zonder kabel in het bestand legt Pro er een aan met standaardwaarden, het rapport meldt het)",[59,3704,586],{},[41,3706,3707,3710,3713],{},[59,3708,3709],{},"Situatieplan",[59,3711,3712],{},"per pagina een verdieping met naam, muren met dikte, ruimtes met naam, deuren met draairichting, ramen, garagepoorten, rechte trappen, vrije teksten (met regeleinden) en rechthoeken, geplaatste toestellen (gekoppeld aan hun kring); ruimtetype uit de naam van de ruimte (bv. ‘Salle de bain’ → badkamer, ‘Keuken’ → keuken; bij onduidelijke namen leeg, het rapport noemt het aantal om na te kijken); volgorde van de verdiepingen uit duidelijke namen (kelder, gelijkvloers, verdiepingen, zolder), anders in de volgorde van de pagina's",[59,3714,3715],{},"leidingen, symbolen zonder tegenhanger in Pro, afbeeldingen van geïmporteerde grondplannen",[41,3717,3718,3721,3723],{},[59,3719,3720],{},"Afdruk",[59,3722,586],{},[59,3724,3725],{},"logo (Pro drukt het logo uit je profiel af), afdrukopties",[10,3727,3728],{},"Beschouw alles wat niet in de kolom \"Overgenomen\" staat als niet overgenomen; het rapport van het betreffende bestand is bepalend.",[10,3730,3731],{},[26,3732],{"id":667},[30,3734,3736],{"id":3735},"hoe-herkent-planelec-duplicaten","Hoe herkent PlanElec duplicaten?",[10,3738,3739,3740,3742],{},"PlanElec vergelijkt de inhoud van de bestanden via een vingerafdruk (SHA-256), niet de naam. Een hernoemde kopie, een bestand dat tweemaal in de ZIP zit en een bestand uit een eerdere run zijn duplicaten. De vergelijking gebeurt binnen de gekozen bestemming, dus ",[19,3741,3397],{}," of de organisatie, en alleen met projecten die niet gearchiveerd zijn en die je mag zien.",[10,3744,3745],{},[26,3746],{"id":682},[30,3748,3750],{"id":3749},"wat-gebeurt-er-met-mijn-originelen","Wat gebeurt er met mijn originelen?",[35,3752,3753,3763],{},[38,3754,3755],{},[41,3756,3757,3760],{},[44,3758,3759],{},"Bestand",[44,3761,3762],{},"Bewaring",[54,3764,3765,3777,3787,3797],{},[41,3766,3767,3770],{},[59,3768,3769],{},"Aangemaakt project",[59,3771,3772,3773,3776],{},"Het origineel staat als projectbestand bij de ",[19,3774,3775],{},"Projectstukken"," van het project en blijft zolang het project bestaat. De kopie die voor de verwerking diende, wordt gewist.",[41,3778,3779,3784],{},[59,3780,3781,3782],{},"Niet-geïmporteerd bestand, toestemming uit en geen klik op ",[19,3783,3600],{},[59,3785,3786],{},"Het origineel wordt na 30 dagen gewist.",[41,3788,3789,3794],{},[59,3790,3791,3792],{},"Niet-geïmporteerd bestand, met toestemming of na ",[19,3793,3600],{},[59,3795,3796],{},"Het origineel blijft tot 12 maanden bewaard voor analyse, zodat de import voor zulke bestanden beter wordt. Het resultaat voor je eigen bestand verandert niet.",[41,3798,3799,3802],{},[59,3800,3801],{},"Duplicaat of geannuleerd bestand",[59,3803,3804],{},"Wordt niet bewaard; resten wist PlanElec na een dag.",[10,3806,3807],{},"De lijst met bestanden van een run (namen, mappen) wist PlanElec 12 maanden na afronding. Je bestanden op je computer worden alleen gelezen, nooit gewijzigd. De gebruiksstatistieken van de import bevatten cijfers en codes, geen bestandsnamen.",[10,3809,3810],{},[26,3811],{"id":748},[30,3813,3815],{"id":3814},"hoe-open-ik-één-bestand-in-sketch-en-neem-ik-het-over-in-pro","Hoe open ik één bestand in Sketch en neem ik het over in Pro?",[10,3817,3818,3819,3822,3823,3826,3827,3829],{},"PlanElec Sketch is de weg zonder account. Open het bestand via ",[19,3820,3821],{},"Document → Openen"," of vanaf de startpagina (\"Trikker-bestand (.trik) openen\"), lees het importrapport en werk verder aan het eendraadschema. Daarna toont Sketch de tip \"Je hele Trikker-archief overzetten?\" met de knop ",[19,3824,3825],{},"Naar PlanElec Pro",". Wil je in Pro verder plannen, kies dan ",[19,3828,3185],{},". Het situatieplan gaat mee: verdiepingen, muren, ruimtes, openingen, trappen, teksten, rechthoeken en geplaatste toestellen staan daarna op de grondplan in Pro. Sketch opent bestanden tot 8 MB.",[30,3831,3833],{"id":3832},"veelgestelde-vragen","Veelgestelde vragen",[390,3835,3837],{"id":3836},"heb-ik-een-pro-abonnement-nodig","Heb ik een Pro-abonnement nodig?",[10,3839,3840],{},"Nee. De import staat open voor elk aangemeld account, ook met \"Pro uitproberen\". Welke Pro-functies je daarna in het project gebruikt, hangt af van je tarief.",[390,3842,3844],{"id":3843},"moet-trikker-geïnstalleerd-zijn","Moet Trikker geïnstalleerd zijn?",[10,3846,3847],{},"Nee. De import leest de inhoud van de bestanden.",[390,3849,3851],{"id":3850},"kan-ik-een-trikker-pdf-importeren","Kan ik een Trikker-PDF importeren?",[10,3853,3854,3855,3857,3858,3861],{},"Niet met ",[19,3856,3149],{},". Een PDF met het grondplan laat je lezen door de ",[26,3859,3860],{"href":3204},"grondplanherkenning"," of leg je als sjabloon onder je tekening.",[390,3863,3865],{"id":3864},"wat-als-ik-een-run-onderbreek","Wat als ik een run onderbreek?",[10,3867,3868],{},"Staat het opladen langer dan 30 minuten stil, dan sluit PlanElec de run af. Bestanden die niet aankwamen, staan in het rapport als niet geïmporteerd. Start ze daarna opnieuw; al aangemaakte projecten worden als duplicaat overgeslagen.",[390,3870,3872],{"id":3871},"is-een-geïmporteerd-project-gecontroleerd","Is een geïmporteerd project gecontroleerd?",[10,3874,3875],{},"Nee. Het is een vertrekpunt. Vergelijk enkele projecten met het origineel, lees de opmerkingen en laat de zelfcontrole in Pro lopen. Die toont openstaande punten en is geen attest; de keuring doet het erkend organisme.",[10,3877,3878,3879,3883],{},"Meer over de achtergrond en over het verhuizen van een heel archief staat in het blogartikel ",[26,3880,3882],{"href":3881},"\u002Fnl\u002Fblog\u002Ftrikker-archief-verhuizen","Trikker-archief verhuizen naar PlanElec Pro",". Trikker is een merk van zijn eigenaar; PlanElec gebruikt de naam alleen om naar het product te verwijzen.",{"title":822,"searchDepth":823,"depth":823,"links":3885},[3886,3887,3888,3889,3892,3893,3894,3895,3896,3897],{"id":3119,"depth":823,"text":3120},{"id":3226,"depth":823,"text":3227},{"id":3260,"depth":823,"text":3261},{"id":3332,"depth":823,"text":3333,"children":3890},[3891],{"id":3462,"depth":831,"text":3463},{"id":3536,"depth":823,"text":3537},{"id":3613,"depth":823,"text":3614},{"id":3735,"depth":823,"text":3736},{"id":3749,"depth":823,"text":3750},{"id":3814,"depth":823,"text":3815},{"id":3832,"depth":823,"text":3833,"children":3898},[3899,3900,3901,3902,3903],{"id":3836,"depth":831,"text":3837},{"id":3843,"depth":831,"text":3844},{"id":3850,"depth":831,"text":3851},{"id":3864,"depth":831,"text":3865},{"id":3871,"depth":831,"text":3872},"Importeer Trikker-bestanden (.trik) in PlanElec Pro, één voor één of als archief: ingang, bestanden of ZIP kiezen, voorvertoning, bestemming, voortgang met e-mail, rapport. Met de grenzen, wat wel en niet wordt overgenomen en Sketch en grondplanimport als alternatief.","nl",{},"\u002Fhelp\u002Ftrikker-import.nl",{"title":3100,"description":3904},"trikker-projecten-importeren","help\u002Ftrikker-import.nl",[861,16,862,3912,3913,865,3914],"batchimport","archief","verhuis","ECmTcm67pnH-YE0kPh_d9Jp5_aYKKXkdsi09Ae-o2EA",[3917,5154,5468,6107,7186,7775,8021,8165,8619,9135,9499,9973,10876,11658,12672,13480,14925,15996,16561,17149],{"id":3918,"title":3919,"body":3920,"category":844,"description":5135,"extension":846,"guideId":5136,"image":5137,"locale":849,"meta":5138,"navigation":851,"order":5139,"path":5140,"publishedAt":5141,"readTime":5142,"seo":5143,"seoTitle":857,"slug":5144,"stem":5145,"tags":5146,"updatedAt":854,"__hash__":5153},"help\u002Fhelp\u002Fgetting-started.fr.md","Premiers pas : du nouveau projet au premier PDF",{"type":7,"value":3921,"toc":5116},[3922,3932,3938,3943,3947,4022,4025,4030,4034,4037,4099,4117,4122,4126,4129,4194,4200,4220,4223,4231,4235,4238,4319,4326,4351,4354,4399,4402,4407,4411,4432,4439,4447,4451,4485,4496,4501,4505,4511,4522,4533,4541,4545,4593,4616,4621,4625,4632,4709,4712,4717,4721,4732,4736,4759,4770,4775,4779,4782,4792,4864,4872,4888,4895,4900,4904,4907,5020,5024,5048,5060,5064,5067,5079,5084,5088,5102,5109],[10,3923,3924,3925,3927,3928,3931],{},"Pour votre premier projet, il vous faut un compte PlanElec et un navigateur à jour. Vous créez le projet dans le studio avec ",[19,3926,278],{},", choisissez l’une des deux approches de planification et avancez à partir du plan ou du schéma unifilaire jusqu’au mode ",[19,3929,3930],{},"Export",". Vous y téléchargez d’abord chaque document en brouillon. Toutes les sections travaillent sur le même modèle de projet : plan, installation, tableau, schéma unifilaire et documents ne se mettent jamais à jour séparément. L’autocontrôle RGIE vous signale les points ouverts dans les règles prises en charge ; le contrôle officiel relève de l’organisme agréé.",[3933,3934,3935],"blockquote",{},[10,3936,3937],{},"Vous utilisez PlanElec en tant que propriétaire ou maître d’ouvrage ? Faites vérifier vos choix et vos documents par un électricien qualifié avant l’exécution et le contrôle.",[10,3939,3940],{},[26,3941],{"id":3942},"project",[30,3944,3946],{"id":3945},"comment-créer-un-nouveau-projet","Comment créer un nouveau projet ?",[261,3948,3949,3961,3975,3989,3995,4015],{},[152,3950,3951,3952,3955,3956,17,3958,3960],{},"Dans le studio, ouvrez le panneau ",[19,3953,3954],{},"Projets"," et cliquez sur le bouton plus ",[19,3957,278],{},[19,3959,278],{}," figure aussi dans le menu du projet, que vous ouvrez avec le bouton bleu PlanElec en haut à gauche.",[152,3962,3963,3964,3966,3967,3970,3971,3974],{},"Dans la fenêtre ",[19,3965,278],{},", saisissez un ",[19,3968,3969],{},"Nom"," d’au moins deux caractères. La ",[19,3972,3973],{},"Description"," est facultative.",[152,3976,3977,3978,3981,3982,293,3985,3988],{},"Sous ",[19,3979,3980],{},"Approche de planification",", choisissez ",[19,3983,3984],{},"Planifier à partir du plan",[19,3986,3987],{},"Dessiner d'abord le schéma unifilaire"," (voir la section suivante).",[152,3990,3991,3992],{},"Avec l’approche par le plan, choisissez votre point de départ sous ",[19,3993,3994],{},"Comment souhaitez-vous commencer ?",[152,3996,3977,3997,4000,4001,4004,4005,4004,4008,293,4011,4014],{},[19,3998,3999],{},"Type de projet",", indiquez le contexte : ",[19,4002,4003],{},"Nouvelle construction",", ",[19,4006,4007],{},"Documenter une installation existante",[19,4009,4010],{},"Extension",[19,4012,4013],{},"Rénovation",".",[152,4016,4017,4018,4021],{},"Cliquez sur ",[19,4019,4020],{},"Créer",". PlanElec crée le projet et l’ouvre dans le studio.",[10,4023,4024],{},"Si le nom manque, la fenêtre revient au champ du nom et en indique la raison. Les choix de cette fenêtre modifient uniquement l’accompagnement ; tous les outils de l’éditeur restent disponibles quelle que soit l’approche.",[10,4026,4027],{},[26,4028],{"id":4029},"planning-path",[30,4031,4033],{"id":4032},"plan-ou-schéma-unifilaire-quelle-approche-choisir","Plan ou schéma unifilaire : quelle approche choisir ?",[10,4035,4036],{},"Les deux approches créent le même type de projet. Seul le point de départ change.",[35,4038,4039,4056],{},[38,4040,4041],{},[41,4042,4043,4045,4048,4053],{},[44,4044,3980],{},[44,4046,4047],{},"Pour qui",[44,4049,4050,4051],{},"Après ",[19,4052,4020],{},[44,4054,4055],{},"Bon à savoir",[54,4057,4058,4078],{},[41,4059,4060,4065,4068,4075],{},[59,4061,4062,4064],{},[19,4063,3984],{}," (Recommandé)",[59,4066,4067],{},"Ceux qui saisissent pièces et appareils dans l’espace",[59,4069,4070,4071,4074],{},"Le mode ",[19,4072,4073],{},"Plan"," s’ouvre ; selon le point de départ, le guidage ou un modèle démarre",[59,4076,4077],{},"Le schéma unifilaire est généré à partir des pièces, appareils et circuits saisis",[41,4079,4080,4084,4087,4096],{},[59,4081,4082],{},[19,4083,3987],{},[59,4085,4086],{},"Les habitués des outils de dessin classiques",[59,4088,4070,4089,4092,4093,4095],{},[19,4090,4091],{},"Électricité"," s’ouvre avec le ",[19,4094,569],{}," agrandi ; un tableau principal et une tête d’installation sont prêts comme hypothèse",[59,4097,4098],{},"Vous placez les symboles directement dans le schéma. Sans plan dessiné, le plan de position reste hors du dossier et les contrôles spatiaux ne bloquent ni le schéma ni le rapport d’autocontrôle. Tous les autres contrôles s’appliquent",[10,4100,4101,4102,4105,4106,4109,4110,4112,4113,4116],{},"Vous pouvez changer d’approche plus tard dans le menu du projet, ",[19,4103,4104],{},"Paramètres du projet…",", section ",[19,4107,4108],{},"Général",". Le changement ne modifie que le point de départ et les réglages d’export ; le schéma, le plan et le tableau restent inchangés. Les fichiers Trikker (",[14,4111,16],{},") deviennent des projets sans partir d’un projet vide : ",[26,4114,69],{"href":4115},"\u002Ffr\u002Fhelp\u002Fimporter-des-projets-trikker",". PlanElec n’importe pas les fichiers de projet d’autres logiciels de planification.",[10,4118,4119],{},[26,4120],{"id":4121},"entry-modes",[30,4123,4125],{"id":4124},"démarrer-avec-un-guide-un-modèle-ou-sans-guidage","Démarrer avec un guide, un modèle ou sans guidage ?",[10,4127,4128],{},"Avec l’approche par le plan, la fenêtre propose quatre points de départ :",[35,4130,4131,4141],{},[38,4132,4133],{},[41,4134,4135,4138],{},[44,4136,4137],{},"Point de départ",[44,4139,4140],{},"Ce qu’il fait",[54,4142,4143,4164,4174,4184],{},[41,4144,4145,4150],{},[59,4146,4147,4064],{},[19,4148,4149],{},"Construire avec un guide",[59,4151,4152,4153,4156,4157,4160,4161,4014],{},"Lance le workflow ",[19,4154,4155],{},"Relever l’installation"," et ouvre le coach dans le panneau ",[19,4158,4159],{},"Workflow",". Il vous mène du bâtiment jusqu’à ",[19,4162,4163],{},"Vérifier et confirmer le schéma",[41,4165,4166,4171],{},[59,4167,4168],{},[19,4169,4170],{},"Partir d’un modèle",[59,4172,4173],{},"Charge un projet de départ préparé et lance également le guidage.",[41,4175,4176,4181],{},[59,4177,4178],{},[19,4179,4180],{},"Commencer par le plan de position",[59,4182,4183],{},"Vous placez d’abord les récepteurs, puis planifiez l’installation ; le coffret et les emplacements restent à définir. Lance également le guidage.",[41,4185,4186,4191],{},[59,4187,4188],{},[19,4189,4190],{},"Sans guidage",[59,4192,4193],{},"Ouvre directement l’éditeur libre avec tous les outils, sans coach.",[10,4195,3977,4196,4199],{},[19,4197,4198],{},"Choisir un projet de départ",", trois modèles sont disponibles :",[149,4201,4202,4208,4214],{},[152,4203,4204,4207],{},[19,4205,4206],{},"Petit appartement"," : cinq locaux, des récepteurs standard et un tableau principal à deux rangées.",[152,4209,4210,4213],{},[19,4211,4212],{},"Maison familiale"," : plusieurs étages, des circuits résidentiels types et un tableau principal à trois rangées.",[152,4215,4216,4219],{},[19,4217,4218],{},"Relevé d’une installation existante"," : un point de départ compact pour une ancienne installation existante.",[10,4221,4222],{},"Un modèle est un exemple, pas une étude pour votre bâtiment. Adaptez pièces, appareils et tableaux à l’installation réelle. Le coach signale les étapes déjà réalisées dans le projet. Vous pouvez passer une étape ou terminer le workflow ; les données du projet sont conservées.",[10,4224,4225,4228],{},[26,4226],{"id":4227},"floorplan",[26,4229],{"id":4230},"situation-plan",[30,4232,4234],{"id":4233},"dessiner-téléverser-ou-faire-reconnaître-le-plan-par-lia","Dessiner, téléverser ou faire reconnaître le plan par l’IA",[10,4236,4237],{},"Le studio est organisé en modes, que vous choisissez dans la barre de gauche. Chaque mode apporte ses outils et panneaux :",[35,4239,4240,4250],{},[38,4241,4242],{},[41,4243,4244,4247],{},[44,4245,4246],{},"Mode",[44,4248,4249],{},"Usage",[54,4251,4252,4261,4271,4280,4290,4300,4310],{},[41,4253,4254,4258],{},[59,4255,4256],{},[19,4257,4073],{},[59,4259,4260],{},"Murs, pièces, portes, fenêtres, escaliers, plans de référence et calibrage",[41,4262,4263,4268],{},[59,4264,4265],{},[19,4266,4267],{},"Mobilier",[59,4269,4270],{},"Aménagement comme repère sur le plan",[41,4272,4273,4277],{},[59,4274,4275],{},[19,4276,4091],{},[59,4278,4279],{},"Appareils, chaînes d’interrupteurs, circuits, tracés de câbles, installation",[41,4281,4282,4287],{},[59,4283,4284],{},[19,4285,4286],{},"Domotique",[59,4288,4289],{},"Lignes de bus, tableau et canaux de l’automatisation",[41,4291,4292,4297],{},[59,4293,4294],{},[19,4295,4296],{},"Lumière",[59,4298,4299],{},"Planification de l’éclairage et étude d’éclairage",[41,4301,4302,4307],{},[59,4303,4304],{},[19,4305,4306],{},"Énergie",[59,4308,4309],{},"Installation PV",[41,4311,4312,4316],{},[59,4313,4314],{},[19,4315,3930],{},[59,4317,4318],{},"Contrôler, télécharger et archiver les documents",[10,4320,4321,4322,4325],{},"Sur un étage vide, PlanElec demande ",[19,4323,4324],{},"Comment souhaitez-vous commencer cet étage ?"," et propose trois voies :",[149,4327,4328,4334,4342],{},[152,4329,4330,4333],{},[19,4331,4332],{},"Dessiner le plan"," : vous créez les locaux directement sur le plan de position.",[152,4335,4336,4339,4340,4014],{},[19,4337,4338],{},"Téléverser un plan"," : un PDF, une image ou un DXF sert de calque à redessiner. Réglez pages, extraits et échelle comme décrit dans ",[26,4341,119],{"href":118},[152,4343,4344,4347,4348],{},[19,4345,4346],{},"Reconnaître le plan automatiquement"," : murs et pièces arrivent comme proposition à partir d’un PDF ou d’une image. Vous vérifiez l’ébauche et mesurez une distance connue avant de la reprendre. La page est transmise à un fournisseur d’IA externe pour analyse. Le déroulement et les limites sont expliqués dans ",[26,4349,4350],{"href":123},"Comment faire reconnaître un plan par l’IA ?",[10,4352,4353],{},"Pour dessiner vous-même :",[261,4355,4356,4369,4376,4389,4392],{},[152,4357,4358,4359,4361,4362,293,4365,4368],{},"En mode ",[19,4360,4073],{},", choisissez l’outil ",[19,4363,4364],{},"Polygone",[19,4366,4367],{},"Rectangle",". Saisissez les dimensions exactes pendant le tracé : Tab change de champ, Entrée valide.",[152,4370,4371,4372,4375],{},"Fermez le contour. PlanElec reconnaît les surfaces fermées comme des pièces ; ",[19,4373,4374],{},"Diviser la pièce"," sépare une pièce en deux.",[152,4377,4378,4379,4004,4382,120,4385,4388],{},"Placez ",[19,4380,4381],{},"Porte",[19,4383,4384],{},"Fenêtre",[19,4386,4387],{},"Escalier"," à leur position réelle.",[152,4390,4391],{},"Sélectionnez une pièce et définissez son type, par exemple cuisine, salle de bains ou local technique. Les recommandations d’appareils en dépendent.",[152,4393,4394,4395,4014],{},"Ajoutez les autres étages. Chaque étage se traite séparément ; leur superposition est expliquée dans ",[26,4396,4398],{"href":4397},"\u002Ffr\u002Fhelp\u002Faligner-les-etages-et-origine-du-batiment","Aligner les étages et l’origine du bâtiment",[10,4400,4401],{},"Critère de réussite : chaque pièce est fermée, nommée et typée. Vous pouvez alors placer les appareils.",[10,4403,4404],{},[26,4405],{"id":4406},"devices",[30,4408,4410],{"id":4409},"placer-et-relier-les-appareils","Placer et relier les appareils",[261,4412,4413,4419,4422,4429],{},[152,4414,4415,4416,4418],{},"Passez en mode ",[19,4417,4091],{},". La palette du bas affiche les recommandations par pièce et le catalogue d’appareils.",[152,4420,4421],{},"Placez prises, interrupteurs, luminaires, raccordements fixes, boîtes de dérivation et le tableau. Les symboles muraux s’alignent sur le mur.",[152,4423,4424,4425,4428],{},"Reliez interrupteurs et luminaires avec l’outil ",[19,4426,4427],{},"Chaîne d'interrupteurs",". Pour les interrupteurs et luminaires libres d’une pièce, PlanElec propose une chaîne ; vérifiez l’ordre avant de l’accepter.",[152,4430,4431],{},"Contrôlez la liste des composants non connectés et non placés. Un symbole du plan ne fait partie du modèle électrique que lorsque son lien avec la topologie est correct.",[10,4433,4434,4435,4014],{},"Palette, icônes et topologie en détail : ",[26,4436,4438],{"href":4437},"\u002Ffr\u002Fhelp\u002Fplacer-et-relier-des-symboles-electriques","Placer et relier des symboles électriques",[10,4440,4441,4444],{},[26,4442],{"id":4443},"automatic-planning",[26,4445],{"id":4446},"cabinet",[30,4448,4450],{"id":4449},"planifier-circuits-installation-et-tableau","Planifier circuits, installation et tableau",[261,4452,4453,4466,4476,4482],{},[152,4454,4455,4456,17,4459,4462,4463,4014],{},"Ouvrez le panneau ",[19,4457,4458],{},"Installation",[19,4460,4461],{},"Compléter l’installation automatiquement"," planifie circuits et protections à partir des récepteurs ouverts. Vérifiez l’aperçu (tableau cible, circuits, protections), puis cliquez sur ",[19,4464,4465],{},"Appliquer la proposition",[152,4467,4468,4469,4472,4473,4014],{},"Affectez un appareil isolé avec ",[19,4470,4471],{},"Affecter le circuit"," et définissez les chemins de câbles avec ",[19,4474,4475],{},"Tracé de câble",[152,4477,4455,4478,4481],{},[19,4479,4480],{},"Tableau",". Le placement automatique dispose interrupteurs principaux, différentiels et disjoncteurs sur les rails DIN après un aperçu, en gardant une réserve.",[152,4483,4484],{},"Vérifiez la chaîne de protection, la répartition des phases, les emplacements des modules et les avertissements affichés.",[10,4486,4487,4488,120,4492,4014],{},"Chaque étape automatique est une proposition modifiable. Vérifiez ensuite l’affectation au tableau et au circuit, les protections, les données de câble, les boîtes de dérivation et les longueurs calculées. Pour aller plus loin : ",[26,4489,4491],{"href":4490},"\u002Ffr\u002Fhelp\u002Fplanification-automatique","Planification automatique",[26,4493,4495],{"href":4494},"\u002Ffr\u002Fhelp\u002Fplanifier-installation-et-tableaux-secondaires","Planifier l’installation et former des tableaux secondaires",[10,4497,4498],{},[26,4499],{"id":4500},"schema",[30,4502,4504],{"id":4503},"contrôler-le-schéma-unifilaire-et-lautocontrôle","Contrôler le schéma unifilaire et l’autocontrôle",[10,4506,4507,4508,4510],{},"Le schéma unifilaire est généré à partir de la même topologie. Ouvrez le panneau ",[19,4509,569],{}," et vérifiez noms de circuits, protections, données de câble, modes de pose et symboles. Si une affectation est incorrecte, corrigez le récepteur, le circuit ou le tronçon de câble dans le modèle, pas seulement le dessin.",[10,4512,4513,4514,4517,4518],{},"Le panneau ",[19,4515,4516],{},"Analyse"," affiche les constats de l’autocontrôle RGIE. Il couvre une partie documentée des règles qui peuvent être tranchées à partir des données saisies. Un passage sans erreur signifie : aucune erreur dans ces règles prises en charge. Les mesures, les conditions sur place et les règles non modélisées restent en dehors. La couverture exacte est décrite dans ",[26,4519,4521],{"href":4520},"\u002Ffr\u002Fhelp\u002Fce-que-verifie-l-autocontrole","Que vérifie l’autocontrôle RGIE de PlanElec ?",[10,4523,4524,4527,4530],{},[26,4525],{"id":4526},"export",[26,4528],{"id":4529},"exports",[26,4531],{"id":4532},"first-pdf",[4534,4535],"help-figure",{":height":4536,":width":4537,"alt":4538,"caption":4539,"src":4540},"223","870","Vue Export avec une carte de document du schéma unifilaire, aperçu, brouillon et état de remise finale verrouillé.","Le statut de la carte décrit l’état de travail disponible ; la remise finale verrouillée ne s’ouvre qu’après la validation de l’export.","\u002Fhelp\u002Fworkflows\u002Ffr-document-selection.png",[30,4542,4544],{"id":4543},"comment-obtenir-mon-premier-pdf","Comment obtenir mon premier PDF ?",[261,4546,4547,4556,4566,4576,4582],{},[152,4548,4415,4549,4551,4552,4555],{},[19,4550,3930],{},". Le panneau ",[19,4553,4554],{},"Documents"," s’ouvre.",[152,4557,3977,4558,4561,4562,4565],{},[19,4559,4560],{},"Une source de données pour tous les documents",", vérifiez les données du projet et complétez-les avec ",[19,4563,4564],{},"Modifier les métadonnées"," : client, adresse de l’installation, installateur, numéro d’agrément et EAN.",[152,4567,4568,4569,4571,4572,4575],{},"Sur la carte ",[19,4570,569],{},", ouvrez l’",[19,4573,4574],{},"Aperçu"," et contrôlez les pages et le cartouche.",[152,4577,4017,4578,4581],{},[19,4579,4580],{},"Télécharger le brouillon",". Vous obtenez un PDF marqué comme brouillon pour un contrôle visuel.",[152,4583,4584,4585,4588,4589,4592],{},"Lisez le statut de la carte : sous ",[19,4586,4587],{},"Corrections nécessaires",", le point suivant apparaît comme lien, par exemple ",[19,4590,4591],{},"Vérifier et confirmer le schéma unifilaire",". Un clic vous y mène.",[10,4594,4595,4596,4599,4600,293,4603,4606,4607,4611,4612,4014],{},"Le bouton ",[19,4597,4598],{},"Créer la version de remise"," ne s’active que lorsque la carte affiche ",[19,4601,4602],{},"Prêt pour remise",[19,4604,4605],{},"Prêt avec remarques"," ; vous confirmez les remarques avant l’archivage. PlanElec archive alors cette version sur le serveur avec un numéro de version. Ce qui est conservé et comment vérifier le code QR est expliqué dans ",[26,4608,4610],{"href":4609},"\u002Ffr\u002Fhelp\u002Farchiver-et-verifier-les-documents","Archiver les documents par version et les vérifier par code QR",". Tous les documents, statuts et le dossier sont décrits dans ",[26,4613,4615],{"href":4614},"\u002Ffr\u002Fhelp\u002Fexporter-les-documents","Exporter les documents",[10,4617,4618],{},[26,4619],{"id":4620},"help",[30,4622,4624],{"id":4623},"où-trouver-de-laide-dans-le-studio","Où trouver de l’aide dans le studio ?",[10,4626,4627,4628,4631],{},"Le point d’interrogation ",[19,4629,4630],{},"Aide"," de la barre d’en-tête ouvre un menu avec ces entrées :",[35,4633,4634,4644],{},[38,4635,4636],{},[41,4637,4638,4641],{},[44,4639,4640],{},"Entrée",[44,4642,4643],{},"Ce qui se passe",[54,4645,4646,4656,4666,4676,4689,4699],{},[41,4647,4648,4653],{},[59,4649,4650],{},[19,4651,4652],{},"Aide rapide",[59,4654,4655],{},"S’affiche dans les vues plan, installation, tableau et schéma unifilaire avec cinq étapes courtes.",[41,4657,4658,4663],{},[59,4659,4660],{},[19,4661,4662],{},"Lancer la visite du studio",[59,4664,4665],{},"Présente tour à tour le menu du projet, la barre des modes, la barre d’outils, la palette, les panneaux, la vue, les étages, le statut, la recherche et l’assistant.",[41,4667,4668,4673],{},[59,4669,4670],{},[19,4671,4672],{},"Ouvrir le tutoriel pratique",[59,4674,4675],{},"Huit chapitres à réaliser : Dessiner le plan, Placer appareils et tableau, Créer la toiture, Poser les champs PV, Générer le tableau, Raccorder le PV, Créer et poser les câbles, Contrôler et exporter.",[41,4677,4678,4683],{},[59,4679,4680],{},[19,4681,4682],{},"Recommencer la configuration guidée",[59,4684,4685,4686,4688],{},"Relance le workflow ",[19,4687,4155],{}," et ouvre le coach.",[41,4690,4691,4696],{},[59,4692,4693],{},[19,4694,4695],{},"Ouvrir le guide correspondant",[59,4697,4698],{},"Ouvre l’article de la base de connaissances sur la vue actuelle dans un nouvel onglet.",[41,4700,4701,4706],{},[59,4702,4703],{},[19,4704,4705],{},"Résoudre les problèmes courants",[59,4707,4708],{},"Ouvre le guide des problèmes fréquents, quelle que soit la vue active.",[10,4710,4711],{},"La visite et le tutoriel ne sont disponibles que dans le studio.",[10,4713,4714],{},[26,4715],{"id":4716},"assistant",[30,4718,4720],{"id":4719},"demander-de-laide-à-lassistant-ia","Demander de l’aide à l’assistant IA",[10,4722,4723,4724,4727,4728],{},"Dans le panneau ",[19,4725,4726],{},"Activité et assistant",", vous écrivez à l’assistant PlanElec en français, en néerlandais, en allemand ou en anglais. Il répond aux questions techniques avec des sources issues de l’aide et du texte intégral du RGIE, et il exécute des instructions de planification dans le projet, par exemple pour les pièces, les appareils, les circuits ou le tableau. Les modifications claires et réversibles s’appliquent directement ; les actions plus risquées demandent votre confirmation. Chaque modification constitue une étape annulable et figure dans l’historique du projet. Chaque exécution consomme votre quota IA. Pour en savoir plus : ",[26,4729,4731],{"href":4730},"\u002Ffr\u002Fhelp\u002Fstudio-activite-assistant","Comment utiliser l’activité et l’assistant dans le studio ?",[30,4733,4735],{"id":4734},"liste-de-contrôle-avant-le-premier-téléchargement","Liste de contrôle avant le premier téléchargement",[149,4737,4738,4741,4744,4747,4750,4753,4756],{},[152,4739,4740],{},"Tous les étages et toutes les pièces sont créés, nommés et typés.",[152,4742,4743],{},"Les symboles électriques se trouvent au bon endroit.",[152,4745,4746],{},"Les récepteurs sont reliés à la topologie, au circuit et au tableau.",[152,4748,4749],{},"Les données et longueurs calculées ou manuelles des câbles ont été vérifiées.",[152,4751,4752],{},"Le tableau et la chaîne de protection correspondent au montage prévu.",[152,4754,4755],{},"Les données du projet, du client, de l’installateur et de l’installation sont complètes.",[152,4757,4758],{},"Les constats de l’autocontrôle ont été examinés et évalués.",[10,4760,4761,4762,4765,4766],{},"Un électricien qualifié vérifie les données et les exports avant les travaux ; l’évaluation officielle est rendue par l’organisme agréé. En cas de blocage, consultez ",[26,4763,4705],{"href":4764},"\u002Ffr\u002Fhelp\u002Fresoudre-les-problemes-courants",". Pas encore de compte ? ",[26,4767,4769],{"href":4768},"\u002Fauth\u002Fregister","Inscrivez-vous gratuitement à PlanElec",[10,4771,4772],{},[26,4773],{"id":4774},"autosave",[30,4776,4778],{"id":4777},"comment-enregistrer-mon-projet-est-il-enregistré-automatiquement","Comment enregistrer ? Mon projet est-il enregistré automatiquement ?",[10,4780,4781],{},"Oui. PlanElec enregistre automatiquement chaque modification dans le studio, environ 1,5 seconde après la dernière action et, si vous travaillez sans interruption, au plus tard après quelques secondes. Cela vaut pour tout le projet : plan, pièces, appareils, circuits et toutes les autres données. Il n’y a pas de bouton Enregistrer : vous n’avez rien à sauvegarder manuellement.",[10,4783,4784,4785,293,4788,4791],{},"L’état de l’enregistrement s’affiche dans l’indicateur rond de la barre d’état, en bas à droite du studio. Un clic ouvre le détail : état, heure du dernier enregistrement, connexion (",[19,4786,4787],{},"En ligne",[19,4789,4790],{},"Hors ligne",") et dernier état complet du serveur.",[35,4793,4794,4803],{},[38,4795,4796],{},[41,4797,4798,4801],{},[44,4799,4800],{},"Affichage",[44,4802,405],{},[54,4804,4805,4815,4825,4835,4845,4854],{},[41,4806,4807,4812],{},[59,4808,4809],{},[19,4810,4811],{},"Enregistré",[59,4813,4814],{},"Toutes les modifications sont sur le serveur.",[41,4816,4817,4822],{},[59,4818,4819],{},[19,4820,4821],{},"Enregistrement...",[59,4823,4824],{},"La dernière modification est en cours d’envoi.",[41,4826,4827,4832],{},[59,4828,4829],{},[19,4830,4831],{},"Non enregistré",[59,4833,4834],{},"Des modifications attendent le prochain enregistrement automatique.",[41,4836,4837,4842],{},[59,4838,4839],{},[19,4840,4841],{},"Enregistré localement",[59,4843,4844],{},"Les modifications sont conservées dans ce navigateur ; la sauvegarde serveur suit.",[41,4846,4847,4851],{},[59,4848,4849],{},[19,4850,4790],{},[59,4852,4853],{},"Pas de connexion. Les modifications sont enregistrées localement.",[41,4855,4856,4861],{},[59,4857,4858],{},[19,4859,4860],{},"Échec de l'enregistrement",[59,4862,4863],{},"Le serveur n’a pas accepté la modification ; le détail en indique la raison.",[10,4865,4866,4869,4870,4014],{},[19,4867,4868],{},"Sans connexion internet",", vous continuez à travailler. PlanElec conserve les modifications dans ce navigateur et les envoie automatiquement dès que la connexion revient. Si vous fermez l’onglet, PlanElec envoie encore les modifications en attente à la fermeture ; ce qui n’arrive pas est rattrapé à la prochaine ouverture du projet dans le même navigateur. N’effacez donc pas les données du navigateur tant que l’indicateur n’affiche pas ",[19,4871,4811],{},[10,4873,4874,4877,4878,4880,4881,4884,4885,4014],{},[19,4875,4876],{},"En cas de conflit",", par exemple si le même projet a été modifié entre-temps sur un autre appareil, l’indicateur le signale. PlanElec conserve alors votre version locale comme brouillon. Vous le trouvez dans le panneau ",[19,4879,3954],{}," sous ",[19,4882,4883],{},"Brouillons récupérés"," et l’ouvrez avec ",[19,4886,4887],{},"Ouvrir le brouillon comme copie du projet",[10,4889,4890,4891,4894],{},"Pour revenir sur une seule action, utilisez ",[19,4892,4893],{},"Annuler"," : la flèche en haut à droite du studio ou Ctrl+Z (Mac : Cmd+Z).",[10,4896,4897],{},[26,4898],{"id":4899},"start-over",[30,4901,4903],{"id":4902},"comment-recommencer-à-zéro-ou-effacer-une-partie-du-projet","Comment recommencer à zéro ou effacer une partie du projet ?",[10,4905,4906],{},"Pour tout recommencer, créez un nouveau projet et archivez l’ancien. Pour n’effacer qu’une partie, supprimez de manière ciblée des appareils, des pièces, un plan importé (calque) ou un étage. Il n’existe pas de bouton « tout effacer » qui vide tout un projet en une fois.",[35,4908,4909,4922],{},[38,4910,4911],{},[41,4912,4913,4916,4919],{},[44,4914,4915],{},"Objectif",[44,4917,4918],{},"Chemin dans le studio",[44,4920,4921],{},"Récupération",[54,4923,4924,4937,4958,4973,4987,5003],{},[41,4925,4926,4929,4934],{},[59,4927,4928],{},"Repartir de zéro",[59,4930,4931,4932],{},"Menu du projet → ",[19,4933,278],{},[59,4935,4936],{},"Le projet existant reste inchangé.",[41,4938,4939,4942,4947],{},[59,4940,4941],{},"Retirer l’ancien projet de la liste",[59,4943,4931,4944],{},[19,4945,4946],{},"Archiver",[59,4948,4949,4951,4952,4951,4955],{},[19,4950,3954],{}," → ",[19,4953,4954],{},"Afficher les archives",[19,4956,4957],{},"Restaurer",[41,4959,4960,4963,4969],{},[59,4961,4962],{},"Supprimer tous les appareils d’une pièce, garder les murs",[59,4964,4965,4966],{},"Clic droit sur la pièce → ",[19,4967,4968],{},"Supprimer les appareils",[59,4970,4971],{},[19,4972,4893],{},[41,4974,4975,4978,4983],{},[59,4976,4977],{},"Supprimer une pièce avec ses murs et appareils",[59,4979,4965,4980],{},[19,4981,4982],{},"Supprimer la pièce",[59,4984,4985],{},[19,4986,4893],{},[41,4988,4989,4992,4998],{},[59,4990,4991],{},"Supprimer un plan importé (image, PDF, DXF)",[59,4993,4994,4997],{},[19,4995,4996],{},"Plans"," → icône corbeille",[59,4999,5000,5002],{},[19,5001,4893],{}," ; la couche est conservée 7 jours",[41,5004,5005,5008,5017],{},[59,5006,5007],{},"Supprimer un étage entier",[59,5009,5010,5011,4951,5014],{},"Barre des étages → ",[19,5012,5013],{},"Gérer les étages",[19,5015,5016],{},"Supprimer …",[59,5018,5019],{},"La boîte de dialogue avertit d’une suppression définitive.",[390,5021,5023],{"id":5022},"créer-un-nouveau-projet-et-archiver-lancien","Créer un nouveau projet et archiver l’ancien",[261,5025,5026,5029,5040],{},[152,5027,5028],{},"Ouvrez le menu du projet avec le bouton bleu PlanElec en haut à gauche.",[152,5030,5031,5032,5034,5035,5037,5038,4014],{},"Choisissez ",[19,5033,278],{},". Vous pouvez aussi ouvrir le panneau ",[19,5036,3954],{}," dans la barre de gauche et y choisir l’icône plus ",[19,5039,278],{},[152,5041,5042,5043,5045,5046,4014],{},"Revenez à l’ancien projet et choisissez ",[19,5044,4946],{}," dans le menu du projet. Confirmez avec ",[19,5047,4946],{},[10,5049,5050,5051,5053,5054,5056,5057,5059],{},"Un projet archivé disparaît de la liste et reste conservé dans les archives. Vous le récupérez dans le panneau ",[19,5052,3954],{}," via ",[19,5055,4954],{}," puis ",[19,5058,4957],{},". L’archivage est réservé aux utilisateurs disposant du droit de modification. L’interface ne propose pas de suppression définitive d’un projet entier.",[390,5061,5063],{"id":5062},"vider-ou-supprimer-une-pièce","Vider ou supprimer une pièce",[10,5065,5066],{},"Dans le plan, faites un clic droit sur une pièce ; sur un écran tactile, maintenez la pièce enfoncée.",[149,5068,5069,5074],{},[152,5070,5071,5073],{},[19,5072,4968],{}," retire tous les appareils de la pièce. Les murs restent.",[152,5075,5076,5078],{},[19,5077,4982],{}," retire les murs et tous les appareils de la pièce. Les murs intérieurs partagés avec d’autres pièces sont conservés.",[10,5080,5081,5082,4014],{},"Les deux actions demandent une confirmation et s’annulent en une seule étape avec ",[19,5083,4893],{},[390,5085,5087],{"id":5086},"supprimer-un-étage","Supprimer un étage",[10,5089,5090,5091,5093,5094,5097,5098,5101],{},"Dans la barre des étages en haut à droite, ouvrez le menu ",[19,5092,5013],{}," (icône à trois points) et choisissez ",[19,5095,5096],{},"Supprimer ‹nom de l’étage› …",". La boîte de dialogue ",[19,5099,5100],{},"Supprimer l'étage ?"," indique les appareils, escaliers, chaînes d’interrupteurs, tracés de câbles et couches de plan concernés. L’étage et toutes ses données sont supprimés ; les couches de plan associées sont encore conservées sept jours. Le dernier étage restant ne peut pas être supprimé.",[10,5103,5104,5105,4014],{},"Pour retirer uniquement un plan importé, consultez le ",[26,5106,5108],{"href":5107},"\u002Ffr\u002Fhelp\u002Fimporter-et-etalonner-un-plan#delete","guide sur l’importation de plans",[10,5110,5111,5112,4765,5114,4014],{},"n électricien qualifié vérifie les données et les exports avant les travaux ; l’évaluation officielle est rendue par l’organisme agréé. En cas de blocage, consultez ",[26,5113,4705],{"href":4764},[26,5115,4769],{"href":4768},{"title":822,"searchDepth":823,"depth":823,"links":5117},[5118,5119,5120,5121,5122,5123,5124,5125,5126,5127,5128,5129,5130],{"id":3945,"depth":823,"text":3946},{"id":4032,"depth":823,"text":4033},{"id":4124,"depth":823,"text":4125},{"id":4233,"depth":823,"text":4234},{"id":4409,"depth":823,"text":4410},{"id":4449,"depth":823,"text":4450},{"id":4503,"depth":823,"text":4504},{"id":4543,"depth":823,"text":4544},{"id":4623,"depth":823,"text":4624},{"id":4719,"depth":823,"text":4720},{"id":4734,"depth":823,"text":4735},{"id":4777,"depth":823,"text":4778},{"id":4902,"depth":823,"text":4903,"children":5131},[5132,5133,5134],{"id":5022,"depth":831,"text":5023},{"id":5062,"depth":831,"text":5063},{"id":5086,"depth":831,"text":5087},"Créez un projet, partez du plan ou du schéma unifilaire, utilisez le guidage, un modèle ou la reconnaissance de plan par IA, puis produisez votre premier PDF provisoire.","getting-started","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fgetting-started-fr.webp",{},1,"\u002Fhelp\u002Fgetting-started.fr","2026-07-20","11 min",{"title":3919,"description":5135},"bien-demarrer","help\u002Fgetting-started.fr",[5147,5148,5149,5150,5151,5152],"projet","plan de position","plan","récepteurs","tableau électrique","schéma unifilaire","1AZKxOthhaceZxw8iJ5KgYdeZcDZR_iAXvFvM8UXPzA",{"id":5155,"title":5156,"body":5157,"category":5452,"description":5453,"extension":846,"guideId":4443,"image":5454,"locale":849,"meta":5455,"navigation":851,"order":823,"path":5456,"publishedAt":5141,"readTime":855,"seo":5457,"seoTitle":5458,"slug":5459,"stem":5460,"tags":5461,"updatedAt":5466,"__hash__":5467},"help\u002Fhelp\u002Fautomatic-planning.fr.md","Planification automatique : récepteurs, câbles, circuits et tableau",{"type":7,"value":5158,"toc":5441},[5159,5162,5166,5169,5186,5189,5193,5200,5204,5207,5241,5244,5250,5254,5257,5260,5267,5287,5290,5294,5297,5300,5317,5320,5326,5330,5334,5337,5361,5364,5368,5372,5375,5379,5382,5405,5409,5412,5415,5426,5430,5436],[10,5160,5161],{},"Les automatismes de PlanElec accélèrent les étapes répétitives. Ils produisent des propositions à partir des pièces, équipements et relations topologiques déjà enregistrés. Le résultat reste modifiable et doit toujours être comparé à l'installation prévue ou existante.",[30,5163,5165],{"id":5164},"avant-de-commencer","Avant de commencer",[10,5167,5168],{},"Les propositions automatiques sont plus pertinentes lorsque les données de départ sont complètes :",[149,5170,5171,5174,5177,5180,5183],{},[152,5172,5173],{},"le bâtiment, les étages et les pièces fermées sont créés ;",[152,5175,5176],{},"les pièces sont nommées et classées de manière cohérente ;",[152,5178,5179],{},"le tableau se trouve dans la bonne pièce et est correctement relié dans le projet ;",[152,5181,5182],{},"le régime de réseau et la configuration des pôles sont définis ;",[152,5184,5185],{},"les appareils spéciaux déjà connus sont placés et correctement typés.",[10,5187,5188],{},"Enregistrez le projet et traitez les composants signalés comme non connectés avant de lancer l'affectation générale des circuits.",[10,5190,5191],{},[26,5192],{"id":4443},[4534,5194],{":height":5195,":width":5196,"alt":5197,"caption":5198,"src":5199},"594","720","Panneau d’actions de la pièce avec des propositions de planification automatique.","Les propositions restent modifiables et ne décident ni des quantités ni des positions finales.","\u002Fhelp\u002Fworkflows\u002Ffr-room-automation.png",[30,5201,5203],{"id":5202},"planifier-automatiquement-les-récepteurs","Planifier automatiquement les récepteurs",[10,5205,5206],{},"Selon la pièce et l'outil sélectionné, plusieurs assistants sont disponibles dans le plan :",[149,5208,5209,5216,5222,5229,5235],{},[152,5210,5211,5212,5215],{},"les ",[19,5213,5214],{},"propositions de prises"," répartissent des prises en fonction de la géométrie de la pièce ;",[152,5217,5211,5218,5221],{},[19,5219,5220],{},"propositions d'éclairage"," placent des points lumineux comme base de travail ;",[152,5223,5224,5225,5228],{},"l'",[19,5226,5227],{},"équipement standard"," ajoute des équipements électriques courants pour le type de pièce ;",[152,5230,5211,5231,5234],{},[19,5232,5233],{},"grilles de spots"," créent des spots régulièrement espacés dans la zone choisie ;",[152,5236,5211,5237,5240],{},[19,5238,5239],{},"chaînes d'interrupteurs"," relient les interrupteurs et luminaires libres d'une pièce dans un ordre proposé.",[10,5242,5243],{},"Contrôlez chaque proposition dans l'aperçu ou directement sur le plan. Tenez compte des portes, fenêtres, éléments fixes, meubles, locaux humides et de l'usage réel. Supprimez, déplacez ou complétez les équipements avant de passer aux circuits.",[10,5245,5246,5247,4014],{},"Lorsque la position d’un boîtier est déjà fixée, aucune proposition n’est nécessaire : l’assistant PlanElec place prises, interrupteurs et prises de données exactement à cet endroit à partir d’une phrase indiquant le mur, l’angle, la distance et la hauteur. Le fonctionnement est décrit dans ",[26,5248,5249],{"href":4730},"Activité et assistant dans le studio",[30,5251,5253],{"id":5252},"spécifier-et-tracer-automatiquement-les-câbles","Spécifier et tracer automatiquement les câbles",[10,5255,5256],{},"PlanElec crée les segments de câble à partir des relations réelles de la topologie électrique. Une boîte de connexion ou de dérivation ne divise le chemin en plusieurs segments que si elle est reliée comme un vrai nœud topologique ; la proximité spatiale ne suffit pas.",[10,5258,5259],{},"Pour un équipement connecté, le trajet peut être calculé automatiquement le long des murs :",[10,5261,5262,5263,5266],{},"Dans le plan de position, ouvrez ",[19,5264,5265],{},"Liaisons et câbles → Tracé de câble"," dans la barre d’outils supérieure.",[261,5268,5269,5272,5275,5278,5281,5284],{},[152,5270,5271],{},"Vérifiez le départ et l'arrivée du segment.",[152,5273,5274],{},"Lancez le tracé automatique.",[152,5276,5277],{},"Examinez le chemin sur le plan. Entre des ensembles de murs séparés, une ligne directe de secours peut apparaître.",[152,5279,5280],{},"Ajoutez ou déplacez des points de passage manuels si nécessaire.",[152,5282,5283],{},"Vérifiez la longueur calculée. Une longueur saisie manuellement est prioritaire.",[152,5285,5286],{},"Contrôlez le type, la section et les conditions de pose du câble dans le contexte professionnel.",[10,5288,5289],{},"Les longueurs nettes calculées alimentent la liste de câbles, la vue matériel et les contrôles pris en charge. Les chutes et réserves de chantier ne sont pas ajoutées automatiquement comme quantités de commande.",[30,5291,5293],{"id":5292},"affecter-automatiquement-les-circuits","Affecter automatiquement les circuits",[10,5295,5296],{},"L'affectation automatique regroupe les points d'éclairage et les prises ordinaires et traite séparément les appareils spéciaux pris en charge. Certains appareils fixes reçoivent notamment un circuit dédié. Dans le modèle actuel, une borne de recharge constitue un cas particulier avec sa propre chaîne de protection.",[10,5298,5299],{},"Procédez comme suit :",[261,5301,5302,5305,5308,5311,5314],{},[152,5303,5304],{},"Ouvrez l'affectation automatique depuis le parcours guidé ou la section du tableau.",[152,5306,5307],{},"Vérifiez l'aperçu : groupe de récepteurs, tableau, protections, phase et données de câble proposées.",[152,5309,5310],{},"N'acceptez la proposition que si le regroupement correspond au projet.",[152,5312,5313],{},"Si nécessaire, déplacez manuellement une branche de récepteurs vers un autre disjoncteur. PlanElec met alors à jour ensemble le circuit, le tableau, la phase et les relations de câble concernées.",[152,5315,5316],{},"Contrôlez ensuite les constats et les composants non connectés.",[10,5318,5319],{},"Pour plusieurs tableaux, l'affectation automatique multi-tableaux peut être utilisée. Dans une installation triphasée, l'équilibrage répartit les charges sur L1, L2 et L3 et affiche un avertissement en cas de déséquilibre marqué. Il s'agit d'une aide à la planification, pas d'une mesure de l'installation réelle.",[4534,5321],{":height":5322,":width":5196,"alt":5323,"caption":5324,"src":5325},"182","Panneau des chemins de câbles avec le tracé automatique et les points de passage manuels.","Le chemin est une aide à la planification ; son parcours, sa longueur et sa faisabilité doivent être comparés au trajet prévu.","\u002Fhelp\u002Fworkflows\u002Ffr-cable-routing.png",[10,5327,5328],{},[26,5329],{"id":4446},[30,5331,5333],{"id":5332},"remplir-automatiquement-le-tableau","Remplir automatiquement le tableau",[10,5335,5336],{},"Le placement automatique organise les interrupteurs principaux, différentiels et disjoncteurs existants sur les rails DIN du coffret choisi.",[261,5338,5339,5342,5345,5352,5355,5358],{},[152,5340,5341],{},"Choisissez le coffret, le nombre de rangées et la configuration des pôles.",[152,5343,5344],{},"Indiquez si la rangée principale doit se trouver en haut ou en bas.",[152,5346,5347,5348,5351],{},"Lancez le ",[19,5349,5350],{},"placement automatique",". PlanElec ordonne les protections et réserve par défaut 20 % de l'espace sur rail.",[152,5353,5354],{},"Vérifiez les emplacements libres, la largeur des modules et les groupes protégés.",[152,5356,5357],{},"Contrôlez les connexions visibles entre interrupteur principal, différentiels et disjoncteurs.",[152,5359,5360],{},"Ajoutez les connexions manquantes avec l'outil de liaison ou déplacez les modules manuellement.",[10,5362,5363],{},"Les chemins de boîtes de connexion explicitement modélisés sont conservés lors d'un nouveau placement automatique. Un modèle interne invalide ou incomplet n'est toutefois pas considéré comme professionnellement complet.",[10,5365,5366],{},[26,5367],{"id":4500},[30,5369,5371],{"id":5370},"contrôler-le-schéma-unifilaire-après-lautomatisation","Contrôler le schéma unifilaire après l'automatisation",[10,5373,5374],{},"Après l'affectation des circuits, la planification des câbles et le placement du tableau, ouvrez le schéma unifilaire. Vérifiez que les protections, dérivations, récepteurs et indications de câble sont complets et plausibles. Corrigez les relations métier dans le modèle de projet commun et relancez l'auto-contrôle pris en charge après chaque modification pertinente.",[30,5376,5378],{"id":5377},"cycle-de-contrôle-recommandé","Cycle de contrôle recommandé",[10,5380,5381],{},"Après une modification importante, répétez cette courte séquence :",[261,5383,5384,5387,5390,5393,5396,5399,5402],{},[152,5385,5386],{},"Vérifier les équipements et leurs positions dans les pièces.",[152,5388,5389],{},"Traiter les composants non connectés.",[152,5391,5392],{},"Contrôler l'affectation des circuits ou demander une nouvelle proposition.",[152,5394,5395],{},"Actualiser les segments et trajets de câble.",[152,5397,5398],{},"Replacer le tableau et vérifier la chaîne de protection.",[152,5400,5401],{},"Recontrôler le schéma unifilaire et l'auto-contrôle RGIE pris en charge.",[152,5403,5404],{},"Générer ensuite seulement de nouveaux PDF ou de nouvelles listes.",[30,5406,5408],{"id":5407},"limites-de-lautomatisation","Limites de l'automatisation",[10,5410,5411],{},"Les propositions automatiques ne connaissent que les données saisies dans le projet. Elles ne peuvent pas évaluer les conditions sur place, les mesures, les justificatifs des fabricants ni les parties de l'installation qui ne sont pas modélisées. Un auto-contrôle sans erreur signifie uniquement qu'aucune erreur n'a été trouvée dans les règles actuellement prises en charge et évaluables.",[10,5413,5414],{},"PlanElec ne remplace ni l'étude, ni l'exécution, ni le contrôle officiel. Seul un organisme de contrôle agréé rend l'évaluation officielle.",[10,5416,5417,5418,5421,5422,4014],{},"Étape suivante : ",[26,5419,5420],{"href":4614},"exporter les documents et les listes"," ou revenir à la ",[26,5423,5425],{"href":5424},"\u002Ffr\u002Fhelp","base de connaissances",[30,5427,5429],{"id":5428},"poursuivre-la-planification-de-linstallation","Poursuivre la planification de l’installation",[10,5431,5432,5433,5435],{},"Dans ",[19,5434,4458],{},", vous pouvez aussi affecter les appareils existants à un circuit, suivre leurs protections et former des tableaux secondaires après prévisualisation. Le coffret et les emplacements des modules peuvent rester ouverts. L’ordre proposé sert de repère ; les projets existants et d’autres points de départ restent possibles.",[10,5437,5438,4014],{},[26,5439,5440],{"href":4494},"Guide illustré de planification de l’installation",{"title":822,"searchDepth":823,"depth":823,"links":5442},[5443,5444,5445,5446,5447,5448,5449,5450,5451],{"id":5164,"depth":823,"text":5165},{"id":5202,"depth":823,"text":5203},{"id":5252,"depth":823,"text":5253},{"id":5292,"depth":823,"text":5293},{"id":5332,"depth":823,"text":5333},{"id":5370,"depth":823,"text":5371},{"id":5377,"depth":823,"text":5378},{"id":5407,"depth":823,"text":5408},{"id":5428,"depth":823,"text":5429},"automation","Utilisez les propositions automatiques de PlanElec pour les équipements, les chemins de câble, les circuits, les phases et l’implantation du tableau.","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fautomatic-planning-fr.webp",{},"\u002Fhelp\u002Fautomatic-planning.fr",{"title":5156,"description":5453},"Planification automatique : récepteurs, câbles, circuits","planification-automatique","help\u002Fautomatic-planning.fr",[5462,5150,5463,5464,5465,5151],"planification automatique","câbles","circuits","phases","2026-10-10","VfbZzFgSjaNeBi-f12vNkcZFTQrCSpY-d-44HJBrVxo",{"id":5469,"title":5470,"body":5471,"category":4529,"description":6091,"extension":846,"guideId":6092,"image":6093,"locale":849,"meta":6094,"navigation":851,"order":831,"path":6095,"publishedAt":5141,"readTime":5142,"seo":6096,"seoTitle":6097,"slug":6098,"stem":6099,"tags":6100,"updatedAt":6105,"__hash__":6106},"help\u002Fhelp\u002Fdocument-exports.fr.md","Exporter les documents et les réunir dans un dossier d’installation",{"type":7,"value":5472,"toc":6078},[5473,5482,5486,5488,5492,5587,5602,5607,5611,5620,5685,5706,5714,5718,5738,5787,5790,5797,5801,5848,5851,5855,5859,5862,5867,5871,5874,5879,5893,5897,5922,5925,5932,5936,5951,5956,5960,6000,6003,6010,6014,6039,6044,6048,6068],[10,5474,5475,5476,5478,5479,5481],{},"Tous les documents se créent dans le studio, en mode ",[19,5477,3930],{},", panneau ",[19,5480,4554],{},". Il vous faut un projet enregistré qui contient les données du document concerné, par exemple une topologie pour le schéma unifilaire. Vous téléchargez d’abord chaque document en brouillon PDF ; une fois les conditions d’export remplies, vous créez une version de remise, que PlanElec archive sans modification et avec numéro de version sur le serveur. Les documents sélectionnés peuvent être réunis dans un dossier d’installation avec page de garde, sommaire et pagination continue, par exemple comme dossier de remise ou de contrôle. Toutes les sorties proviennent du même modèle de projet et portent les mêmes données de projet et d’installateur. Le rapport d’autocontrôle vous signale les points ouverts dans les règles RGIE prises en charge ; le contrôle de conformité relève de l’organisme agréé.",[10,5483,5484],{},[26,5485],{"id":4529},[4534,5487],{":height":4536,":width":4537,"alt":4538,"caption":4539,"src":4540},[30,5489,5491],{"id":5490},"quels-documents-existent-et-quel-est-leur-statut","Quels documents existent et quel est leur statut ?",[35,5493,5494,5506],{},[38,5495,5496],{},[41,5497,5498,5501,5503],{},[44,5499,5500],{},"Document",[44,5502,402],{},[44,5504,5505],{},"Contenu et limites",[54,5507,5508,5520,5531,5544,5556,5575],{},[41,5509,5510,5514,5517],{},[59,5511,5512],{},[19,5513,569],{},[59,5515,5516],{},"disponible",[59,5518,5519],{},"PDF multipage issu de la topologie électrique, avec cartouche ; toujours en noir et blanc.",[41,5521,5522,5526,5528],{},[59,5523,5524],{},[19,5525,643],{},[59,5527,5516],{},[59,5529,5530],{},"PDF des étages, pièces et symboles placés, avec légende. Absent du dossier lorsqu’un projet en « Dessiner d'abord le schéma unifilaire » n’a pas de plan dessiné.",[41,5532,5533,5538,5541],{},[59,5534,5535],{},[19,5536,5537],{},"Rapport d'auto-contrôle RGIE",[59,5539,5540],{},"disponible, indicatif",[59,5542,5543],{},"Résultat des règles prises en charge et évaluables à partir des données du projet. Indisponible lorsque l’autocontrôle est désactivé pour le projet.",[41,5545,5546,5551,5553],{},[59,5547,5548],{},[19,5549,5550],{},"Disposition du tableau",[59,5552,5516],{},[59,5554,5555],{},"Sélectionnable dès que le tableau contient des données.",[41,5557,5558,5569,5572],{},[59,5559,5560,4004,5563,4004,5566],{},[19,5561,5562],{},"Liste des circuits",[19,5564,5565],{},"Liste de matériel",[19,5567,5568],{},"Liste des câbles",[59,5570,5571],{},"pilote",[59,5573,5574],{},"Listes génériques, indépendantes des fabricants et fondées sur le modèle, en PDF et CSV ; sans prix ni validation de commande. La validation sur le terrain reste à faire avant la diffusion générale.",[41,5576,5577,5582,5584],{},[59,5578,5579],{},[19,5580,5581],{},"Dossier d’installation",[59,5583,5516],{},[59,5585,5586],{},"Documents sélectionnés avec page de garde personnalisée, sommaire, pagination continue et archivage versionné sur le serveur. Toutes les pages portent le même identifiant de dossier. La validation sur le terrain avec de vrais projets clients reste à faire.",[10,5588,5589,5590,5593,5594,5597,5598,5601],{},"Selon le projet, d’autres entrées apparaissent, comme la ",[19,5591,5592],{},"Liste des conducteurs",", le ",[19,5595,5596],{},"Plan de bornes du tableau"," ou le ",[19,5599,5600],{},"Rapport de rendement PV",". Un rapport de rendement PV à jour est toujours intégré au dossier. Traitez ces sorties comme les listes : ce sont des documents de travail à vérifier sur le plan technique. Avec un profil d’automatisation actif, une section domotique apparaît aussi sous les documents ; ces documents ne font pas partie de l’archivage sur le serveur.",[10,5603,5604],{},[26,5605],{"id":5606},"status",[30,5608,5610],{"id":5609},"que-signifient-brouillon-corrections-nécessaires-et-prêt-pour-remise","Que signifient Brouillon, Corrections nécessaires et Prêt pour remise ?",[10,5612,5613,5614,4004,5616,120,5618,4014],{},"Chaque carte de document affiche un statut et les boutons ",[19,5615,4574],{},[19,5617,4580],{},[19,5619,4598],{},[35,5621,5622,5633],{},[38,5623,5624],{},[41,5625,5626,5628,5630],{},[44,5627,402],{},[44,5629,405],{},[44,5631,5632],{},"Ce que vous pouvez faire",[54,5634,5635,5648,5660,5673],{},[41,5636,5637,5642,5645],{},[59,5638,5639],{},[19,5640,5641],{},"Brouillon",[59,5643,5644],{},"Le document n’a pas encore de contenu ; aperçu et téléchargement sont verrouillés.",[59,5646,5647],{},"Compléter le contenu dans le projet",[41,5649,5650,5654,5657],{},[59,5651,5652],{},[19,5653,4587],{},[59,5655,5656],{},"Au moins un point bloque la version de remise. Le premier point figure en lien sous le statut.",[59,5658,5659],{},"Télécharger un brouillon ; suivre le lien vers la correction",[41,5661,5662,5666,5669],{},[59,5663,5664],{},[19,5665,4602],{},[59,5667,5668],{},"Plus rien n’est ouvert.",[59,5670,5671],{},[19,5672,4598],{},[41,5674,5675,5679,5682],{},[59,5676,5677],{},[19,5678,4605],{},[59,5680,5681],{},"Aucun blocage, mais des remarques, par exemple des données de projet manquantes.",[59,5683,5684],{},"Créer la version de remise et confirmer explicitement les remarques",[10,5686,5687,5688,4004,5690,4004,5693,4004,5696,4004,5699,120,5702,5705],{},"Les points ouverts typiques sont ",[19,5689,4591],{},[19,5691,5692],{},"Compléter et confirmer les modes de pose",[19,5694,5695],{},"Placer les appareils manquants sur le plan de position",[19,5697,5698],{},"Placer les modules manquants sur les rails DIN",[19,5700,5701],{},"Compléter les désignations des circuits",[19,5703,5704],{},"Examiner les résultats de l’autocontrôle",". Un brouillon porte la mention BROUILLON et n’est pas une version de remise archivée.",[10,5707,5708,5711],{},[26,5709],{"id":5710},"metadata",[26,5712],{"id":5713},"branding",[30,5715,5717],{"id":5716},"vérifier-les-données-du-projet-de-linstallateur-et-le-logo","Vérifier les données du projet, de l’installateur et le logo",[10,5719,5720,5721,4004,5723,5725,5726,5728,5729,5731,5732,120,5735,4014],{},"En haut du panneau ",[19,5722,4554],{},[19,5724,4560],{}," résume le projet, le client, l’installation, l’installateur et l’EAN. ",[19,5727,4564],{}," permet de les compléter ; les mêmes champs se trouvent dans le menu du projet sous ",[19,5730,4104],{},", sections ",[19,5733,5734],{},"Client et installation",[19,5736,5737],{},"Intervenants",[35,5739,5740,5750],{},[38,5741,5742],{},[41,5743,5744,5747],{},[44,5745,5746],{},"Donnée",[44,5748,5749],{},"Origine",[54,5751,5752,5762,5772],{},[41,5753,5754,5757],{},[59,5755,5756],{},"Client, adresse de l’installation, EAN",[59,5758,5759,5760],{},"Paramètres du projet, section ",[19,5761,5734],{},[41,5763,5764,5767],{},[59,5765,5766],{},"Installateur, numéro d’agrément, contact, organisme de contrôle",[59,5768,5759,5769,5771],{},[19,5770,5737],{}," ; les champs vides de raison sociale, numéro d’entreprise et adresse sont repris du profil du propriétaire du projet",[41,5773,5774,5777],{},[59,5775,5776],{},"Logo de l’entreprise",[59,5778,5779,5780,4004,5783,5786],{},"Menu du compte ",[19,5781,5782],{},"Mon profil",[19,5784,5785],{},"Logo de l'entreprise"," : PNG ou JPG, max. 500 Ko, min. 200 × 80 px et max. 2000 × 800 px",[10,5788,5789],{},"Le schéma unifilaire, le plan de position, le rapport d’autocontrôle et la page de garde du dossier utilisent à l’export le même instantané de ces données, logo compris. Si le logo ne peut pas être chargé, le document est tout de même créé, simplement sans logo. Les données manquantes comme le nom du client, l’adresse de l’installation, l’installateur ou le numéro d’agrément, ainsi qu’un EAN invalide, apparaissent comme remarques : les brouillons restent possibles, et une version de remise exige que vous confirmiez explicitement ces remarques.",[10,5791,5792,5794],{},[26,5793],{"id":4500},[26,5795],{"id":5796},"single-line",[30,5798,5800],{"id":5799},"comment-exporter-un-document-séparé","Comment exporter un document séparé ?",[261,5802,5803,5809,5820,5834,5840],{},[152,5804,4415,5805,4551,5807,4555],{},[19,5806,3930],{},[19,5808,4554],{},[152,5810,5811,5812,5815,5816,5819],{},"Dans l’",[19,5813,5814],{},"Aperçu du dossier",", choisissez le ",[19,5817,5818],{},"Format des plans"," A4 ou A3. Le schéma unifilaire et le plan de position utilisent ce format ; tableaux et page de garde restent en A4.",[152,5821,5822,5823,5826,5827,293,5830,5833],{},"Si besoin, réglez les ",[19,5824,5825],{},"Couleurs des circuits"," sur ",[19,5828,5829],{},"Couleur",[19,5831,5832],{},"Noir et blanc",". Ce choix concerne le plan de position et la vue du tableau.",[152,5835,5836,5837,5839],{},"Ouvrez l’",[19,5838,4574],{}," sur la carte du document et contrôlez les pages, le cartouche et les bords de page.",[152,5841,4017,5842,5844,5845,4014],{},[19,5843,4580],{}," et ouvrez le fichier hors de PlanElec pour un contrôle visuel. Les listes proposent aussi ",[19,5846,5847],{},"CSV",[10,5849,5850],{},"Pour le schéma unifilaire, vérifiez en particulier que chaque chemin de récepteur aboutit au bon disjoncteur et au bon différentiel, que le type de câble, la section et les libellés sont présents, et que les modules de réserve n’apparaissent pas comme circuits actifs. Les schémas volumineux sont répartis sur plusieurs pages.",[10,5852,5853],{},[26,5854],{"id":4230},[30,5856,5858],{"id":5857},"que-vérifier-sur-le-plan-de-position","Que vérifier sur le plan de position ?",[10,5860,5861],{},"Le plan de position montre pièces, ouvertures et symboles électriques à leur emplacement. Contrôlez chaque étage : libellés qui se chevauchent, appareils manquants, lisibilité dans le format choisi. Le plan de position et le schéma unifilaire partagent le cartouche et les notes du projet ; corrigez ces données dans le projet, pas dans un PDF isolé.",[10,5863,5864],{},[26,5865],{"id":5866},"self-check",[30,5868,5870],{"id":5869},"que-montre-le-rapport-dautocontrôle-rgie","Que montre le rapport d’autocontrôle RGIE ?",[10,5872,5873],{},"Le rapport résume les constats que PlanElec peut évaluer à partir des données saisies et des règles prises en charge. Il indique lorsqu’un contrôle est incomplet ou qu’une partie de l’installation sort de la couverture actuelle. Pour le PV, il contient un registre d’installation explicitement désigné comme registre de planification.",[10,5875,5876,5877],{},"Un rapport sans erreur signifie : aucune erreur dans les règles prises en charge et vérifiables à partir des données. Les mesures, justificatifs des fabricants, conditions sur place et règles non modélisées restent en dehors. Les règles vérifiées sont décrites dans ",[26,5878,4521],{"href":4520},[10,5880,5881,5884,5887,5890],{},[26,5882],{"id":5883},"lists",[26,5885],{"id":5886},"circuit-list",[26,5888],{"id":5889},"cable-list",[26,5891],{"id":5892},"material-list",[30,5894,5896],{"id":5895},"lire-les-listes-de-circuits-de-matériel-et-de-câbles-pilote","Lire les listes de circuits, de matériel et de câbles (pilote)",[149,5898,5899,5905,5914],{},[152,5900,5901,5902,5904],{},"La ",[19,5903,5562],{}," facilite le contrôle des affectations et de la chaîne de protection.",[152,5906,5901,5907,5909,5910,5913],{},[19,5908,5565],{}," s’ouvre avec ",[19,5911,5912],{},"Ouvrir la vue du matériel",", par catégorie ou par pièce. Les contributions sans pièce restent visibles. Les postes saisis manuellement sont signalés comme tels et ne sont jamais fusionnés avec les lignes calculées.",[152,5915,5901,5916,5909,5918,5921],{},[19,5917,5568],{},[19,5919,5920],{},"Ouvrir la liste des câbles",". Elle affiche les segments et les longueurs nettes ; une longueur manuelle remplace la valeur calculée.",[10,5923,5924],{},"La liste de matériel repose sur des hypothèses génériques indépendantes des fabricants. Elle ne contient ni prix, ni référence fabricant concrète, ni réserve de chantier automatique ; les appareils ménagers comptent comme raccordements. La carte le rappelle : la liste contient des quantités issues du modèle et n’est pas une liste d’achat validée. Utilisez-la comme base vérifiable pour une offre.",[10,5926,5927,5929],{},[26,5928],{"id":4446},[26,5930],{"id":5931},"cabinet-pdf",[30,5933,5935],{"id":5934},"exporter-la-disposition-du-tableau","Exporter la disposition du tableau",[10,5937,5901,5938,5940,5941,5943,5944,4004,5947,5950],{},[19,5939,5550],{}," devient sélectionnable dès que le tableau du projet contient des données ; aucun interrupteur ni activation n’est nécessaire. Avec plusieurs tableaux, choisissez dans l’",[19,5942,5814],{},", sous ",[19,5945,5946],{},"Étendue de l'export",[19,5948,5949],{},"Tous les tableaux"," ou un seul tableau. L’étendue s’applique à la composition du tableau, au schéma unifilaire, à la liste des conducteurs et au plan de bornes ; un tableau seul conserve son numéro de feuille du schéma complet. Comparez rangées, emplacements, libellés et réserve avec le montage prévu.",[10,5952,5953],{},[26,5954],{"id":5955},"dossier",[30,5957,5959],{"id":5958},"composer-le-dossier-dinstallation","Composer le dossier d’installation",[261,5961,5962,5967,5980,5983,5988],{},[152,5963,5964,5965,4014],{},"Complétez les données du projet avec ",[19,5966,4564],{},[152,5968,3977,5969,5972,5973,5975,5976,5979],{},[19,5970,5971],{},"Composer le dossier",", cochez uniquement les documents qui correspondent à l’état de travail actuel. L’",[19,5974,5814],{}," les liste sous ",[19,5977,5978],{},"Documents inclus"," dans un ordre fixe.",[152,5981,5982],{},"Vérifiez le format des plans, les couleurs et les autres options.",[152,5984,5836,5985,5987],{},[19,5986,4574],{}," du dossier et contrôlez la page de garde, le sommaire, l’ordre, les cartouches et la pagination continue.",[152,5989,4017,5990,5992,5993,5995,5996,5999],{},[19,5991,4580],{}," pour une version de travail, ou sur ",[19,5994,4598],{}," dès que le ",[19,5997,5998],{},"Dossier final"," est prêt.",[10,6001,6002],{},"Un dossier complet contient le schéma unifilaire, le plan de position et le rapport d’autocontrôle ; l’aperçu indique si votre sélection est complète ou partielle. Avec « Dessiner d'abord le schéma unifilaire » et sans plan dessiné, le dossier est complet sans plan de position.",[10,6004,6005,6008],{},[26,6006],{"id":6007},"release",[26,6009],{"id":864},[30,6011,6013],{"id":6012},"créer-et-archiver-une-version-de-remise","Créer et archiver une version de remise",[10,6015,6016,6018,6019,6022,6023,132,6026,4004,6029,4004,6032,120,6035,6038],{},[19,6017,4598],{}," porte sur l’état enregistré du projet. S’il y a des remarques, PlanElec les affiche d’abord ; avec ",[19,6020,6021],{},"Confirmer les remarques et archiver",", elles font partie de la version enregistrée. La version figure ensuite sous ",[19,6024,6025],{},"Éditions PDF versionnées",[19,6027,6028],{},"PDF",[19,6030,6031],{},"Étiquette PDF",[19,6033,6034],{},"Étiquette PNG",[19,6036,6037],{},"Révoquer le QR",". Son code QR renvoie exactement à cette version d’archive. Les brouillons restent des téléchargements locaux.",[10,6040,6041,6042,4014],{},"Une modification ultérieure du projet ne change pas une version archivée ; pour un nouvel état, vous créez une nouvelle version. L’archivage atteste la provenance et l’intégrité du fichier. Il ne constitue ni un contrôle électrique, ni une attestation de conformité, ni une signature électronique. La vérification d’un document par code QR et la révocation d’un lien sont expliquées dans ",[26,6043,4610],{"href":4609},[30,6045,6047],{"id":6046},"contrôle-qualité-avant-transmission","Contrôle qualité avant transmission",[149,6049,6050,6053,6056,6059,6062,6065],{},[152,6051,6052],{},"Le projet, le client, l’adresse, l’installateur, le logo et la révision sont-ils corrects sur tous les documents ?",[152,6054,6055],{},"Tous les étages, circuits, symboles et libellés de câble sont-ils lisibles ?",[152,6057,6058],{},"Le format et l’ordre des pages correspondent-ils à l’usage prévu ?",[152,6060,6061],{},"Avez-vous vérifié les affectations et longueurs planifiées automatiquement ?",[152,6063,6064],{},"Les constats ouverts ou lacunes de couverture du rapport sont-ils visibles et compris ?",[152,6066,6067],{},"Le dossier ne contient-il que les versions de documents réellement contrôlées ?",[10,6069,6070,6071,6075,6076,4014],{},"Faites vérifier la documentation par l’électricien responsable ; le contrôle officiel relève d’un organisme agréé. Pour construire le modèle de projet, commencez par ",[26,6072,6074],{"href":6073},"\u002Ffr\u002Fhelp\u002Fbien-demarrer","Premiers pas"," ; en cas de difficulté, consultez ",[26,6077,4705],{"href":4764},{"title":822,"searchDepth":823,"depth":823,"links":6079},[6080,6081,6082,6083,6084,6085,6086,6087,6088,6089,6090],{"id":5490,"depth":823,"text":5491},{"id":5609,"depth":823,"text":5610},{"id":5716,"depth":823,"text":5717},{"id":5799,"depth":823,"text":5800},{"id":5857,"depth":823,"text":5858},{"id":5869,"depth":823,"text":5870},{"id":5895,"depth":823,"text":5896},{"id":5934,"depth":823,"text":5935},{"id":5958,"depth":823,"text":5959},{"id":6012,"depth":823,"text":6013},{"id":6046,"depth":823,"text":6047},"Téléchargez en brouillon le schéma unifilaire, le plan de position, le rapport d’autocontrôle, la disposition du tableau et les listes, réunissez-les en dossier et archivez les versions de remise.","document-exports","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fdocument-exports-fr.webp",{},"\u002Fhelp\u002Fdocument-exports.fr",{"title":5470,"description":6091},"Exporter les documents et composer le dossier d’installation","exporter-les-documents","help\u002Fdocument-exports.fr",[6101,5152,5148,6102,6103,6104,5955],"export PDF","RGIE","liste de matériel","liste de câbles","2026-10-11","UU7ZwiYx70xtSvAH1ou_QTpTqbR5IbVNtkjZzFW97oU",{"id":6108,"title":6109,"body":6110,"category":7166,"description":7167,"extension":846,"guideId":7168,"image":7169,"locale":849,"meta":7170,"navigation":851,"order":7171,"path":7172,"publishedAt":7173,"readTime":7174,"seo":7175,"seoTitle":857,"slug":7176,"stem":7177,"tags":7178,"updatedAt":7184,"__hash__":7185},"help\u002Fhelp\u002Fself-check-coverage.fr.md","Que vérifie l'autocontrôle RGIE de PlanElec ?",{"type":7,"value":6111,"toc":7150},[6112,6115,6118,6125,6130,6137,6141,6156,6159,6163,6387,6391,6445,6449,6517,6521,6587,6591,6671,6675,6715,6719,6772,6776,7058,7061,7064,7067,7070,7073,7076,7079,7083,7086,7092,7098,7104,7110,7114,7117,7140,7144,7147],[10,6113,6114],{},"PlanElec réunit deux choses qu'il est facile de confondre.",[10,6116,6117],{},"Les références RGIE ne sont liées publiquement qu’après les validations documentées de la source et du fond. Les règles de pratique et contrôles de plausibilité ne prétendent pas citer le règlement.",[10,6119,6120,6121,6124],{},"L'",[19,6122,6123],{},"autocontrôle automatique"," n'en couvre qu'une partie. Cette page indique précisément laquelle. Nous énumérons les règles vérifiées et les domaines où l'application ne se prononce pas, car un contrôle incomplet qui se présente comme complet est plus dangereux qu'une absence de contrôle.",[3933,6126,6127],{},[10,6128,6129],{},"L'autocontrôle est une préparation. Seul un organisme de contrôle agréé délivre le jugement officiel.",[4534,6131],{":height":6132,":width":6133,"alt":6134,"caption":6135,"src":6136},"485","384","Panneau de l’autocontrôle RGIE avec un constat incomplet et des points ouverts.","Le rapport affiche les contrôles pris en charge et les points ouverts pour préparer la vérification ; une donnée de projet manquante n’est jamais considérée comme réussie.","\u002Fhelp\u002Fworkflows\u002Ffr-self-check.png",[30,6138,6140],{"id":6139},"ce-qui-est-vérifié-automatiquement","Ce qui est vérifié automatiquement",[10,6142,6143,6144,6147,6148,6151,6152,6155],{},"L'application compte actuellement ",[19,6145,6146],{},"59 contrôles",". Parmi eux, ",[19,6149,6150],{},"30"," renvoient à un article précis du RGIE ; les ",[19,6153,6154],{},"29"," autres sont des règles de pratique ou des contrôles de plausibilité, signalés comme tels, sans caractère réglementaire.",[10,6157,6158],{},"Un contrôle ne produit un résultat que si les données de projet nécessaires sont renseignées. À défaut, le rapport marque le contrôle comme incomplet — jamais comme réussi.",[390,6160,6162],{"id":6161},"protection","Protection",[35,6164,6165,6181],{},[38,6166,6167],{},[41,6168,6169,6172,6175,6178],{},[44,6170,6171],{},"Contrôle",[44,6173,6174],{},"Ce qui est vérifié",[44,6176,6177],{},"Base",[44,6179,6180],{},"Gravité",[54,6182,6183,6196,6209,6222,6235,6248,6260,6273,6286,6299,6312,6324,6337,6349,6362,6375],{},[41,6184,6185,6188,6191,6194],{},[59,6186,6187],{},"Différentiel principal",[59,6189,6190],{},"En tête d'installation, un différentiel de 300 mA au maximum doit être présent.",[59,6192,6193],{},"AREI 4.2.4.3",[59,6195,455],{},[41,6197,6198,6201,6204,6207],{},[59,6199,6200],{},"Max. de circuits par différentiel à haute sensibilité",[59,6202,6203],{},"Au maximum 8 circuits terminaux par différentiel à haute sensibilité (≤ 30 mA).",[59,6205,6206],{},"AREI 4.2.4.3.b",[59,6208,455],{},[41,6210,6211,6214,6217,6220],{},[59,6212,6213],{},"Calibres des actionneurs de volets",[59,6215,6216],{},"Les actionneurs de volet sur rail DIN exigent un disjoncteur ou différentiel en amont ; les charges de protection et de moteur restent dans les valeurs d'entrée et de canal du catalogue.",[59,6218,6219],{},"Règle de pratique",[59,6221,455],{},[41,6223,6224,6227,6230,6233],{},[59,6225,6226],{},"Protection des bornes de recharge (VE)",[59,6228,6229],{},"Un point de charge exige un circuit propre, un différentiel dédié et au moins IP44 à l'extérieur.",[59,6231,6232],{},"AREI 7.22.4",[59,6234,455],{},[41,6236,6237,6240,6243,6245],{},[59,6238,6239],{},"Sélectivité des différentiels (recommandation pratique)",[59,6241,6242],{},"Recommandation de pratique : échelonner sensibilité et temporisation entre différentiels amont et aval (CEI 60364-5-53).",[59,6244,6219],{},[59,6246,6247],{},"Information",[41,6249,6250,6253,6256,6258],{},[59,6251,6252],{},"Différentiel 30 mA pour les circuits de prises",[59,6254,6255],{},"Tous les circuits de prises doivent être protégés par un différentiel de 30 mA.",[59,6257,6206],{},[59,6259,455],{},[41,6261,6262,6265,6268,6271],{},[59,6263,6264],{},"Protection contre les surtensions (SPD)",[59,6266,6267],{},"La présence d’un parafoudre (SPD) est évaluée ; le RGIE n’impose pas d’obligation générale.",[59,6269,6270],{},"AREI 4.5.1",[59,6272,6247],{},[41,6274,6275,6278,6281,6284],{},[59,6276,6277],{},"Interrupteur principal min. 40 A",[59,6279,6280],{},"Un interrupteur général doit être présent et atteindre au moins 40 A dans les installations domestiques.",[59,6282,6283],{},"AREI 5.3.5.1.b",[59,6285,455],{},[41,6287,6288,6291,6294,6297],{},[59,6289,6290],{},"Différentiel principal min. 40 A",[59,6292,6293],{},"Le différentiel au point d’alimentation doit présenter un calibre d’au moins 40 A.",[59,6295,6296],{},"AREI 5.3.5.3.a",[59,6298,455],{},[41,6300,6301,6304,6307,6309],{},[59,6302,6303],{},"Implantation du tableau",[59,6305,6306],{},"Tableau : occupation dans la limite des modules, un différentiel par rangée et une réserve d’environ 20 %.",[59,6308,6219],{},[59,6310,6311],{},"Avertissement",[41,6313,6314,6317,6320,6322],{},[59,6315,6316],{},"Chauffage encastré en paroi : différentiel 100 mA",[59,6318,6319],{},"Les résistances chauffantes noyées dans les parois au-delà de 25 V CA exigent un différentiel séparé de 100 mA.",[59,6321,6206],{},[59,6323,455],{},[41,6325,6326,6329,6332,6335],{},[59,6327,6328],{},"Configuration des pôles en installation domestique",[59,6330,6331],{},"Les disjoncteurs unipolaires ne sont pas admis dans les habitations belges en schéma étoile ; utilisez 1P+N.",[59,6333,6334],{},"AREI 4.4.4.2",[59,6336,6311],{},[41,6338,6339,6342,6345,6347],{},[59,6340,6341],{},"Courbe de déclenchement selon le type de charge",[59,6343,6344],{},"Recommandation de pratique : la courbe B, C ou D du disjoncteur doit correspondre au type de charge.",[59,6346,6219],{},[59,6348,6311],{},[41,6350,6351,6354,6357,6360],{},[59,6352,6353],{},"Organe de protection et couplage de la ligne d’alimentation",[59,6355,6356],{},"Une liaison vers un tableau divisionnaire commence à un organe de protection propre dans le tableau amont et lui est couplée sans ambiguïté.",[59,6358,6359],{},"AREI 4.4.2.2",[59,6361,455],{},[41,6363,6364,6367,6370,6373],{},[59,6365,6366],{},"Pouvoir de coupure par rapport au courant de court-circuit",[59,6368,6369],{},"Le pouvoir de coupure de chaque disjoncteur doit supporter le courant de court-circuit présumé ; vérifié uniquement si la valeur est renseignée.",[59,6371,6372],{},"AREI 5.3.5.5",[59,6374,455],{},[41,6376,6377,6380,6383,6385],{},[59,6378,6379],{},"Protection contre les surintensités de l’alimentation d’un tableau divisionnaire",[59,6381,6382],{},"Si un tableau divisionnaire n’est alimenté que par un interrupteur différentiel, la protection amont doit protéger l’alimentation selon le tableau 4.11 ou par la somme des départs ; des données manquantes rendent le contrôle incomplet.",[59,6384,6359],{},[59,6386,455],{},[390,6388,6390],{"id":6389},"mise-à-la-terre","Mise à la terre",[35,6392,6393,6405],{},[38,6394,6395],{},[41,6396,6397,6399,6401,6403],{},[44,6398,6171],{},[44,6400,6174],{},[44,6402,6177],{},[44,6404,6180],{},[54,6406,6407,6420,6433],{},[41,6408,6409,6412,6415,6418],{},[59,6410,6411],{},"Liaison équipotentielle principale",[59,6413,6414],{},"Une liaison équipotentielle principale (barrette de terre) doit être présente.",[59,6416,6417],{},"AREI 4.2.3.2",[59,6419,455],{},[41,6421,6422,6425,6428,6431],{},[59,6423,6424],{},"Prise de terre (boucle\u002Fpiquet)",[59,6426,6427],{},"Pour un réseau TT ou IT, une prise de terre doit être documentée.",[59,6429,6430],{},"AREI 4.2.3",[59,6432,455],{},[41,6434,6435,6438,6441,6443],{},[59,6436,6437],{},"Cohérence de la mise à la terre et du raccordement",[59,6439,6440],{},"Contrôle de plausibilité : un raccordement domestique public 3×230 V avec un schéma TN enregistré demande vérification.",[59,6442,6219],{},[59,6444,6311],{},[390,6446,6448],{"id":6447},"câbles-et-dimensionnement","Câbles et dimensionnement",[35,6450,6451,6463],{},[38,6452,6453],{},[41,6454,6455,6457,6459,6461],{},[44,6456,6171],{},[44,6458,6174],{},[44,6460,6177],{},[44,6462,6180],{},[54,6464,6465,6478,6491,6504],{},[41,6466,6467,6470,6473,6476],{},[59,6468,6469],{},"Section des câbles",[59,6471,6472],{},"La section du câble doit correspondre au calibre de la protection.",[59,6474,6475],{},"AREI 5.2.2",[59,6477,455],{},[41,6479,6480,6483,6486,6489],{},[59,6481,6482],{},"Chute de tension (ΔU)",[59,6484,6485],{},"Chute de tension calculée sur la longueur du câble : valeur indicative de 3 % en éclairage et 5 % pour les autres circuits terminaux.",[59,6487,6488],{},"AREI 5.2.5",[59,6490,455],{},[41,6492,6493,6496,6499,6502],{},[59,6494,6495],{},"Classe de réaction au feu CPR des câbles",[59,6497,6498],{},"Les câbles posés individuellement doivent présenter la propriété F1 ou atteindre au moins la classe CPR Eca ; la classe Fca est interdite.",[59,6500,6501],{},"AREI 5.2.7.2",[59,6503,455],{},[41,6505,6506,6509,6512,6515],{},[59,6507,6508],{},"Pose en parois creuses : Cca\u002FPreflex",[59,6510,6511],{},"Les câbles dans les cavités constructives passent en gaine (Preflex) ou atteignent au moins la classe CPR Cca.",[59,6513,6514],{},"AREI 4.3.3.5.b",[59,6516,455],{},[390,6518,6520],{"id":6519},"charge-des-circuits","Charge des circuits",[35,6522,6523,6535],{},[38,6524,6525],{},[41,6526,6527,6529,6531,6533],{},[44,6528,6171],{},[44,6530,6174],{},[44,6532,6177],{},[44,6534,6180],{},[54,6536,6537,6550,6562,6575],{},[41,6538,6539,6542,6545,6548],{},[59,6540,6541],{},"Domotique : charge du canal",[59,6543,6544],{},"Compare le courant calculé à partir des puissances documentées au courant nominal saisi pour le canal. Une puissance ou un calibre manquant constitue une lacune de données. Ne vérifie ni le courant de démarrage, ni le facteur de puissance, ni la protection interne. (RGIE 4.4.1.1)",[59,6546,6547],{},"AREI 4.4.1.1",[59,6549,455],{},[41,6551,6552,6555,6558,6560],{},[59,6553,6554],{},"Domotique : courant de bus connu",[59,6556,6557],{},"Compare les courants connus des appareils et du catalogue à la capacité prévue du bus. Avertissement de planification fondé sur le catalogue de profils, sans limite numérique du RGIE ; objectif de protection RGIE 4.4.1.1.",[59,6559,6219],{},[59,6561,6311],{},[41,6563,6564,6567,6570,6573],{},[59,6565,6566],{},"Max. prises\u002Fappareils par circuit terminal",[59,6568,6569],{},"Au maximum 8 prises et appareils fixes par circuit terminal ; les points lumineux seuls ne comptent pas.",[59,6571,6572],{},"AREI 5.3.5.2b",[59,6574,455],{},[41,6576,6577,6580,6583,6585],{},[59,6578,6579],{},"Déséquilibre des phases",[59,6581,6582],{},"Recommandation de pratique : le déséquilibre entre phases reste de préférence sous 30 %.",[59,6584,6219],{},[59,6586,6311],{},[390,6588,6590],{"id":6589},"locaux-et-volumes","Locaux et volumes",[35,6592,6593,6605],{},[38,6594,6595],{},[41,6596,6597,6599,6601,6603],{},[44,6598,6171],{},[44,6600,6174],{},[44,6602,6177],{},[44,6604,6180],{},[54,6606,6607,6620,6633,6646,6659],{},[41,6608,6609,6612,6615,6618],{},[59,6610,6611],{},"Protection 30 mA des locaux humides",[59,6613,6614],{},"Les prises des locaux humides doivent être protégées par un différentiel de 30 mA.",[59,6616,6617],{},"AREI 4.2.4.4",[59,6619,455],{},[41,6621,6622,6625,6628,6631],{},[59,6623,6624],{},"Différentiel 30 mA pour les circuits de salle de bains",[59,6626,6627],{},"Tous les circuits des salles de bains et locaux humides doivent être protégés par un différentiel de 30 mA.",[59,6629,6630],{},"AREI 7.1.4.3",[59,6632,455],{},[41,6634,6635,6638,6641,6644],{},[59,6636,6637],{},"Volumes 0\u002F1\u002F2 de salle de bains : admissibilité du matériel",[59,6639,6640],{},"Dans les volumes de salle de bains 0, 1 et 2, seul certain matériel est admis ; les tableaux y sont interdits.",[59,6642,6643],{},"AREI 7.1.5.2",[59,6645,455],{},[41,6647,6648,6651,6654,6657],{},[59,6649,6650],{},"Volumes de piscine 0\u002F1\u002F2 : matériel dans les volumes à contrôler",[59,6652,6653],{},"Le matériel situé dans les volumes 0, 1 et 2 d’une piscine est signalé comme point à contrôler ; les exigences du RGIE 7.2.3 et suivants doivent être vérifiées par un professionnel.",[59,6655,6656],{},"AREI 7.2.2",[59,6658,6247],{},[41,6660,6661,6664,6667,6669],{},[59,6662,6663],{},"Couverture des détecteurs de fumée (recommandation)",[59,6665,6666],{},"Avis non contraignant fondé sur les règles régionales du logement ; le RGIE lui-même n’impose pas de détecteurs de fumée en habitation.",[59,6668,6219],{},[59,6670,6311],{},[390,6672,6674],{"id":6673},"topologie-et-commande","Topologie et commande",[35,6676,6677,6689],{},[38,6678,6679],{},[41,6680,6681,6683,6685,6687],{},[44,6682,6171],{},[44,6684,6174],{},[44,6686,6177],{},[44,6688,6180],{},[54,6690,6691,6703],{},[41,6692,6693,6696,6699,6701],{},[59,6694,6695],{},"Chaînes de commande des volets électriques",[59,6697,6698],{},"Contrôle de plausibilité : interrupteurs directs, entrées d’actionneur, commandes centrales et types de moteur forment un chemin de commande cohérent.",[59,6700,6219],{},[59,6702,455],{},[41,6704,6705,6708,6711,6713],{},[59,6706,6707],{},"Intégrité du projet",[59,6709,6710],{},"Les références entre schéma, plan de position et coffret doivent pointer vers des objets existants.",[59,6712,6219],{},[59,6714,455],{},[390,6716,6718],{"id":6717},"installation-photovoltaïque","Installation photovoltaïque",[35,6720,6721,6733],{},[38,6722,6723],{},[41,6724,6725,6727,6729,6731],{},[44,6726,6171],{},[44,6728,6174],{},[44,6730,6177],{},[44,6732,6180],{},[54,6734,6735,6748,6760],{},[41,6736,6737,6740,6743,6746],{},[59,6738,6739],{},"Conformité de l'installation photovoltaïque",[59,6741,6742],{},"Installation PV : anti-îlotage, mise à la terre des cadres de modules, panneaux d’avertissement et repérage des conducteurs CC et CA.",[59,6744,6745],{},"AREI 7.112.2",[59,6747,455],{},[41,6749,6750,6753,6756,6758],{},[59,6751,6752],{},"Dimensionnement des chaînes PV",[59,6754,6755],{},"Vérifie les chaînes par rapport aux limites fabricant documentées de l’onduleur et des modules.",[59,6757,6219],{},[59,6759,455],{},[41,6761,6762,6765,6768,6770],{},[59,6763,6764],{},"Courant cumulé dans les tableaux à sources multiples",[59,6766,6767],{},"Dans un tableau avec production propre, courants du réseau et de la source s’additionnent par phase sur les tronçons communs.",[59,6769,6219],{},[59,6771,455],{},[390,6773,6775],{"id":6774},"complétude-du-dossier","Complétude du dossier",[35,6777,6778,6790],{},[38,6779,6780],{},[41,6781,6782,6784,6786,6788],{},[44,6783,6171],{},[44,6785,6174],{},[44,6787,6177],{},[44,6789,6180],{},[54,6791,6792,6805,6817,6828,6839,6850,6862,6874,6886,6898,6910,6922,6935,6947,6959,6971,6984,6997,7009,7022,7034,7046],{},[41,6793,6794,6797,6800,6803],{},[59,6795,6796],{},"Domotique : commandes sur le schéma",[59,6798,6799],{},"Pour les installations domestiques, vérifie que les points de commande existants figurent dans les données réelles du schéma. Les affectations manquantes peuvent être complétées dans la matrice des canaux ou via le chemin d’alimentation du module. Ce contrôle ne couvre pas tous les symboles ni toute la très basse tension. (RGIE 3.1.2.1.a)",[59,6801,6802],{},"AREI 3.1.2.1",[59,6804,455],{},[41,6806,6807,6810,6813,6815],{},[59,6808,6809],{},"Protection de l’alimentation domotique",[59,6811,6812],{},"Contrôle de planification : la protection de l’alimentation, l’alimentation du bus et les affectations uniques et complètes des canaux doivent être documentées. Un constat bloque l’export final ; ce n’est pas une obligation supplémentaire du RGIE.",[59,6814,6219],{},[59,6816,455],{},[41,6818,6819,6822,6824,6826],{},[59,6820,6821],{},"Affectation unique des charges",[59,6823,6812],{},[59,6825,6219],{},[59,6827,455],{},[41,6829,6830,6833,6835,6837],{},[59,6831,6832],{},"Alimentation du bus",[59,6834,6812],{},[59,6836,6219],{},[59,6838,455],{},[41,6840,6841,6844,6846,6848],{},[59,6842,6843],{},"Configuration de l’actionneur",[59,6845,6812],{},[59,6847,6219],{},[59,6849,455],{},[41,6851,6852,6855,6858,6860],{},[59,6853,6854],{},"Appareils par ligne",[59,6856,6857],{},"Avertissement de planification fondé sur le catalogue de profils : Appareils par ligne. Les limites et affectations proviennent du catalogue de profils, pas du RGIE.",[59,6859,6219],{},[59,6861,6311],{},[41,6863,6864,6867,6870,6872],{},[59,6865,6866],{},"Lignes par système",[59,6868,6869],{},"Avertissement de planification fondé sur le catalogue de profils : Lignes par système. Les limites et affectations proviennent du catalogue de profils, pas du RGIE.",[59,6871,6219],{},[59,6873,6311],{},[41,6875,6876,6879,6882,6884],{},[59,6877,6878],{},"Charge du canal selon le profil",[59,6880,6881],{},"Avertissement de planification fondé sur le catalogue de profils : Charge du canal selon le profil. Les limites et affectations proviennent du catalogue de profils, pas du RGIE.",[59,6883,6219],{},[59,6885,6311],{},[41,6887,6888,6891,6894,6896],{},[59,6889,6890],{},"Type de canal et charge",[59,6892,6893],{},"Avertissement de planification fondé sur le catalogue de profils : Type de canal et charge. Les limites et affectations proviennent du catalogue de profils, pas du RGIE.",[59,6895,6219],{},[59,6897,6311],{},[41,6899,6900,6903,6906,6908],{},[59,6901,6902],{},"Affectation à une ligne",[59,6904,6905],{},"Avertissement de planification fondé sur le catalogue de profils : Affectation à une ligne. Les limites et affectations proviennent du catalogue de profils, pas du RGIE.",[59,6907,6219],{},[59,6909,6311],{},[41,6911,6912,6915,6918,6920],{},[59,6913,6914],{},"Coupleur de ligne",[59,6916,6917],{},"Avertissement de planification fondé sur le catalogue de profils : Coupleur de ligne. Les limites et affectations proviennent du catalogue de profils, pas du RGIE.",[59,6919,6219],{},[59,6921,6311],{},[41,6923,6924,6927,6930,6933],{},[59,6925,6926],{},"Classes de tension par ligne de bus",[59,6928,6929],{},"Vérifie la présence de SELV avec FELV ou LV sur une même ligne de bus (RGIE 4.2.5.5.c). Avertit d’une contradiction logique ; ne prouve ni les connexions physiques ni la qualité de la source.",[59,6931,6932],{},"AREI 4.2.5.5.c",[59,6934,6311],{},[41,6936,6937,6940,6943,6945],{},[59,6938,6939],{},"Conflits d’adresses KNX",[59,6941,6942],{},"Vérifie que les adresses physiques et les adresses de groupe sont uniques et valides. Contrôle de planification de l’espace d’adressage KNX, pas une exigence RGIE.",[59,6944,6219],{},[59,6946,6311],{},[41,6948,6949,6952,6955,6957],{},[59,6950,6951],{},"Adresses KNX manquantes",[59,6953,6954],{},"Une fois l’adressage commencé, signale les appareils KNX sans adresse physique et les canaux sans adresse de groupe. Information, pas un blocage d’export.",[59,6956,6219],{},[59,6958,6247],{},[41,6960,6961,6964,6967,6969],{},[59,6962,6963],{},"Connexions complètes",[59,6965,6966],{},"Chaque élément du schéma doit être raccordé ; un nœud isolé signale un modèle incomplet.",[59,6968,6219],{},[59,6970,6311],{},[41,6972,6973,6976,6979,6982],{},[59,6974,6975],{},"Nombre minimal de circuits d'éclairage",[59,6977,6978],{},"Recommandation de pratique : au moins deux circuits d’éclairage par unité de logement.",[59,6980,6981],{},"AREI 5.3.5.2.b",[59,6983,455],{},[41,6985,6986,6989,6992,6995],{},[59,6987,6988],{},"Circuits dédiés aux gros appareils",[59,6990,6991],{},"Les gros appareils — lave-linge, sèche-linge, lave-vaisselle, taque et four — exigent chacun un circuit propre.",[59,6993,6994],{},"AREI 5.2.1.2",[59,6996,455],{},[41,6998,6999,7002,7005,7007],{},[59,7000,7001],{},"Dossier de l'installation (RGIE 9.1.2)",[59,7003,7004],{},"Le dossier d’installation exige un schéma unifilaire, un plan de position et un cartouche complet ; le PV demande des documents supplémentaires.",[59,7006,6219],{},[59,7008,6311],{},[41,7010,7011,7014,7017,7020],{},[59,7012,7013],{},"Implantation des boîtes de connexion\u002Fdérivation",[59,7015,7016],{},"Les boîtes de dérivation structurelles doivent apparaître une seule fois et de manière cohérente dans le schéma.",[59,7018,7019],{},"AREI 3.1.2.3",[59,7021,6311],{},[41,7023,7024,7027,7030,7032],{},[59,7025,7026],{},"Consommateurs placés sur le plan de position",[59,7028,7029],{},"Les consommateurs du schéma unifilaire doivent être placés sur le plan de position via leur lien.",[59,7031,6219],{},[59,7033,6311],{},[41,7035,7036,7039,7042,7044],{},[59,7037,7038],{},"Symboles électriques du plan non liés",[59,7040,7041],{},"Les appareils du plan sans lien avec la topologie électrique sont signalés à titre informatif.",[59,7043,6219],{},[59,7045,6247],{},[41,7047,7048,7051,7054,7056],{},[59,7049,7050],{},"Plausibilité des groupes de commande",[59,7052,7053],{},"Contrôle de plausibilité : un groupe de commande contient au moins un interrupteur et au moins une charge commandée.",[59,7055,6219],{},[59,7057,6311],{},[30,7059,4286],{"id":7060},"domotique",[10,7062,7063],{},"Cette section contient des contrôles RGIE, des contrôles obligatoires de planification et des avertissements liés aux profils. Elle ne certifie ni l’ensemble de l’installation à très basse tension, ni la conformité fabricant, ni le cheminement physique du bus. Le type de source d’alimentation du bus n’est pas saisissable dans le modèle (RGIE 4.2.5.3.a).",[10,7065,7066],{},"Domaines non contrôlés automatiquement (aucun contrôle réussi) :",[10,7068,7069],{},"Désactivé : tous les composants internes à très basse tension ne peuvent pas être saisis et représentés sur le schéma. La modification générale annoncée pour juin 2023 n’est pas établie ici. Seul le contrôle documenté des points de commande est actif.",[10,7071,7072],{},"Désactivé : aucun fondement pour imposer systématiquement un circuit de bus dédié avec 30 mA ; le type A est une exigence générale pour les différentiels.",[10,7074,7075],{},"Désactivé : le voisinage des câbles, la distance et les preuves d’isolation ne peuvent pas être renseignés. Le règlement autorise plusieurs mesures de séparation.",[10,7077,7078],{},"Pas de contrôle automatique des symboles : le tableau 2.23 J prescrit le symbole de l’unité de commande (RGIE 3.1.2.1.a). L’utilisateur ne peut pas corriger une géométrie absente du catalogue ou du moteur de rendu.",[30,7080,7082],{"id":7081},"ce-que-lautocontrôle-névalue-pas","Ce que l'autocontrôle n'évalue pas",[10,7084,7085],{},"Ces parties du Livre 1 restent délibérément hors du contrôle automatique :",[10,7087,7088,7091],{},[19,7089,7090],{},"Installations et locaux particuliers (Partie 7)."," Sur quatorze chapitres, PlanElec en touche trois, et chaque fois partiellement : locaux contenant une baignoire ou une douche (7.1), alimentation des véhicules routiers électriques (7.22) et installations photovoltaïques domestiques (7.112). Ne sont pas couverts : les piscines (7.2), les saunas (7.3), les installations de chantier et extérieures (7.4), les enceintes conductrices exiguës (7.6), les campings (7.8), les ports de plaisance (7.9), les installations foraines (7.11), les fontaines (7.100), les véhicules en stationnement (7.101), les atmosphères explosives (7.102) et les batteries d'accumulateurs industrielles (7.103).",[10,7093,7094,7097],{},[19,7095,7096],{},"Le côté courant continu."," Le modèle ne distingue pas les rôles de conducteur L+, L-, M, PEM et PEL. Le choix des conducteurs, les couleurs, les conducteurs de protection combinés, la sensibilité différentielle en continu, la protection du conducteur M et le contrôle permanent d'isolement en schéma IT ne sont donc pas vérifiables. Pour le photovoltaïque, cela reste du travail manuel.",[10,7099,7100,7103],{},[19,7101,7102],{},"Les dispositions transitoires des articles 59 et 69."," L'application d'une exception à une installation existante dépend de données qui ne se déduisent pas d'un schéma unifilaire — notamment la section du PEN, le début effectif des travaux sur place et la présence d'un dispositif de contrôle. PlanElec tient compte des assouplissements de la Partie 8 en présentant certains constats sur les parties existantes comme des indications plutôt que comme des erreurs, mais ne tranche pas lui-même l'exception.",[10,7105,7106,7109],{},[19,7107,7108],{},"Les contrôles des installations (Partie 6) et les prescriptions de comportement (Partie 9)"," sortent du champ d'un outil de planification. Seule la composition du dossier d'installation est vérifiée.",[30,7111,7113],{"id":7112},"ce-quun-logiciel-ne-peut-pas-établir-par-principe","Ce qu'un logiciel ne peut pas établir par principe",[10,7115,7116],{},"Même après extension du modèle, ces points resteront tributaires d'une mesure, d'un document ou d'un contrôle visuel sur place :",[149,7118,7119,7122,7125,7128,7131,7134,7137],{},[152,7120,7121],{},"le câblage réel, la continuité et la polarité des conducteurs ;",[152,7123,7124],{},"les courbes de déclenchement et l'aptitude au continu des appareils effectivement posés ;",[152,7126,7127],{},"la mesure d'isolement et le fonctionnement d'un contrôleur permanent d'isolement ;",[152,7129,7130],{},"la tenue mécanique et chimique ainsi que l'état de corrosion de la mise à la terre ;",[152,7132,7133],{},"l'efficacité de la coupure automatique et l'impédance de terre réelle ;",[152,7135,7136],{},"l'aptitude et la certification des onduleurs, batteries et composants PV ;",[152,7138,7139],{},"le zonage, l'analyse de risque et les conditions du site.",[30,7141,7143],{"id":7142},"ce-que-cela-signifie-pour-votre-contrôle","Ce que cela signifie pour votre contrôle",[10,7145,7146],{},"Utilisez l'autocontrôle pour détecter tôt les erreurs évitables : un différentiel manquant, une section qui ne correspond pas à la protection, trop de points de contact sur un circuit, un dossier incomplet. Ce sont précisément les constats qui, sinon, n'apparaissent qu'à la réception.",[10,7148,7149],{},"N'y comptez pas pour les cas énumérés ci-dessus. Votre expertise et le jugement de l'organisme agréé y restent déterminants.",{"title":822,"searchDepth":823,"depth":823,"links":7151},[7152,7162,7163,7164,7165],{"id":6139,"depth":823,"text":6140,"children":7153},[7154,7155,7156,7157,7158,7159,7160,7161],{"id":6161,"depth":831,"text":6162},{"id":6389,"depth":831,"text":6390},{"id":6447,"depth":831,"text":6448},{"id":6519,"depth":831,"text":6520},{"id":6589,"depth":831,"text":6590},{"id":6673,"depth":831,"text":6674},{"id":6717,"depth":831,"text":6718},{"id":6774,"depth":831,"text":6775},{"id":7060,"depth":823,"text":4286},{"id":7081,"depth":823,"text":7082},{"id":7112,"depth":823,"text":7113},{"id":7142,"depth":823,"text":7143},"compliance","La liste complète des règles vérifiées automatiquement par PlanElec — et une liste tout aussi explicite de ce que l'autocontrôle n'évalue pas.","self-check-coverage","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fself-check-coverage.webp",{},4,"\u002Fhelp\u002Fself-check-coverage.fr","2026-08-17","7 min",{"title":6109,"description":7167},"ce-que-verifie-l-autocontrole","help\u002Fself-check-coverage.fr",[6102,7179,7180,7181,7182,7183],"AREI","autocontrôle","contrôle","couverture","validation","2026-10-14","OrLKS1-NQiLvSrbfrwxC-QTlpcsvfcaFdwf3bj5ZEfM",{"id":7187,"title":119,"body":7188,"category":844,"description":7758,"extension":846,"guideId":7759,"image":7760,"locale":849,"meta":7761,"navigation":851,"order":7762,"path":7763,"publishedAt":7764,"readTime":7765,"seo":7766,"seoTitle":857,"slug":7767,"stem":7768,"tags":7769,"updatedAt":6105,"__hash__":7774},"help\u002Fhelp\u002Ffloorplan-import-calibration.fr.md",{"type":7,"value":7189,"toc":7748},[7190,7197,7201,7208,7212,7229,7268,7320,7323,7328,7332,7339,7365,7368,7373,7377,7386,7389,7394,7398,7431,7434,7468,7471,7475,7483,7486,7500,7505,7510,7514,7517,7596,7601,7606,7610,7616,7648,7654,7665,7681,7736,7740,7743],[10,7191,7192,7193,7196],{},"Dans PlanElec, un plan importé est un ",[19,7194,7195],{},"calque de référence",". Il vous faut un étage existant et un fichier PNG, JPEG, WebP, PDF ou DXF. Après l’importation et l’étalonnage, le plan se trouve à l’échelle sous votre dessin ; vous tracez par-dessus les murs, pièces et symboles électriques sous forme de données PlanElec modifiables. L’export reste ainsi lisible même si vous masquez ou remplacez ensuite le plan original. Si vous préférez ne pas redessiner murs et pièces, l’IA peut les reconnaître comme proposition à partir d’un PDF ou d’une image ; la section « Faire reconnaître le plan automatiquement » explique comment.",[10,7198,7199],{},[26,7200],{"id":862},[4534,7202],{":height":7203,":width":7204,"alt":7205,"caption":7206,"src":7207},"614","768","Dialogue d’ajout de plans avec sélection de fichiers et file d’importation.","Avant l’envoi, vérifiez le type de fichier, l’étage et, le cas échéant, les pages ou les recadrages sélectionnés.","\u002Fhelp\u002Fworkflows\u002Ffr-import-plan.png",[30,7209,7211],{"id":7210},"comment-importer-une-référence-de-plan","Comment importer une référence de plan ?",[10,7213,4358,7214,3981,7216,7218,7219,7222,7223,7225,7226,7228],{},[19,7215,4073],{},[19,7217,4996],{}," dans la barre d’outils, puis ",[19,7220,7221],{},"Ajouter un plan",". Sur un étage vide, ",[19,7224,4338],{}," dans la fenêtre de démarrage ",[19,7227,4324],{}," ouvre la même boîte de dialogue d’importation – pour les images, les PDF et les DXF.",[261,7230,7231,7242,7245,7248,7262],{},[152,7232,7233,7234,7237,7238,7241],{},"Glissez les fichiers dans la boîte de dialogue ",[19,7235,7236],{},"Ajouter des plans"," ou utilisez ",[19,7239,7240],{},"Choisir les fichiers",". PNG, JPEG, WebP, PDF et DXF peuvent être sélectionnés ensemble.",[152,7243,7244],{},"Pour un PDF, sélectionnez les pages nécessaires ; pour un DXF, confirmez l’unité de dessin et désélectionnez les calques inutiles.",[152,7246,7247],{},"Marquez les extraits si nécessaire (voir ci-dessous).",[152,7249,7250,7251,7254,7255,7258,7259,4014],{},"Vérifiez l’affectation aux étages dans la ",[19,7252,7253],{},"File d’importation"," et terminez avec ",[19,7256,7257],{},"Téléverser les couches",". Un fichier en erreur peut être relancé séparément avec ",[19,7260,7261],{},"Réessayer",[152,7263,5031,7264,7267],{},[19,7265,7266],{},"Configurer"," pour un calque afin d’ouvrir l’atelier de calque.",[35,7269,7270,7279],{},[38,7271,7272],{},[41,7273,7274,7277],{},[44,7275,7276],{},"Limite par passage",[44,7278,196],{},[54,7280,7281,7289,7297,7304,7312],{},[41,7282,7283,7286],{},[59,7284,7285],{},"Calques",[59,7287,7288],{},"jusqu’à 20",[41,7290,7291,7294],{},[59,7292,7293],{},"Taille totale",[59,7295,7296],{},"jusqu’à 100 Mo",[41,7298,7299,7301],{},[59,7300,6028],{},[59,7302,7303],{},"jusqu’à 25 Mo et 50 pages",[41,7305,7306,7309],{},[59,7307,7308],{},"DXF",[59,7310,7311],{},"jusqu’à 30 Mo",[41,7313,7314,7317],{},[59,7315,7316],{},"DWG",[59,7318,7319],{},"non importé",[10,7321,7322],{},"Le DXF est traité dans le navigateur comme image de référence. Model Space et les calques sélectionnés sont pris en compte.",[10,7324,7325],{},[26,7326],{"id":7327},"sections",[30,7329,7331],{"id":7330},"séparer-plusieurs-plans-figurant-sur-une-même-planche","Séparer plusieurs plans figurant sur une même planche",[10,7333,7334,7335,7338],{},"Les plans d’architecte portent souvent le rez-de-chaussée, l’étage et les combles sur la même page. À l’étape ",[19,7336,7337],{},"Marquer les extraits",", tracez un rectangle autour de chaque plan – chaque rectangle donne un plan distinct, que vous affectez à son propre étage.",[149,7340,7341,7347,7353,7359],{},[152,7342,7343,7346],{},[19,7344,7345],{},"Sans marquage",", la page entière est reprise.",[152,7348,7349,7352],{},[19,7350,7351],{},"Nommez chaque extrait"," dans la liste sous l’aperçu. Tous les extraits d’une planche portent le même nom de fichier ; seul le nom permet de les distinguer dans la file et dans la liste des plans.",[152,7354,7355,7358],{},[19,7356,7357],{},"Coupes, façades et cartouches restent non marqués."," Seul ce qui porte un rectangle est repris.",[152,7360,7361,7364],{},[19,7362,7363],{},"L’extrait est appliqué au moment de la rastérisation."," Il est donc rendu plus net que la même zone au sein d’une page lue en entier.",[10,7366,7367],{},"Un rectangle peut être déplacé après son tracé et redimensionné par ses coins. Les flèches au-dessus de l’aperçu permettent de parcourir les pages sélectionnées ; les marquages valent par page.",[10,7369,7370],{},[26,7371],{"id":7372},"sources",[30,7374,7376],{"id":7375},"le-fichier-source-reste-dans-le-projet","Le fichier source reste dans le projet",[10,7378,7379,7380,4880,7382,7385],{},"Le fichier téléversé est conservé et figure au bas du panneau ",[19,7381,4996],{},[19,7383,7384],{},"Fichiers sources",". Plusieurs plans d’une même planche renvoient au même fichier ; il n’est enregistré qu’une seule fois.",[10,7387,7388],{},"Vous pouvez ainsi découper un extrait supplémentaire plus tard sans rechercher le fichier – par exemple lorsqu’un étage a été oublié lors de la première importation. Pour un relevé d’installation existante ou un contrôle de conformité, le plan d’architecte reste en outre attaché au projet comme base de la documentation.",[10,7390,7391],{},[26,7392],{"id":7393},"calibrate",[30,7395,7397],{"id":7396},"régler-léchelle-la-rotation-et-la-position","Régler l’échelle, la rotation et la position",[10,7399,7400,7401,7404,7405,4004,7408,4004,7411,120,7414,7417,7418,7420,7421,7423,7424,7427,7428,7430],{},"L’atelier ",[19,7402,7403],{},"Configurer le calque"," propose les étapes ",[19,7406,7407],{},"Recadrer",[19,7409,7410],{},"Pivoter",[19,7412,7413],{},"Échelle",[19,7415,7416],{},"Position",". Si le plan provient d’un extrait marqué, il commence à ",[19,7419,7410],{}," – la zone a déjà été déterminée lors de l’importation. ",[19,7422,7407],{}," reste accessible pour les corrections de bord. Tant que l’atelier est ouvert, le déplacement et le zoom restent disponibles, mais les outils de dessin sont verrouillés. Les modifications restent un brouillon jusqu’à ",[19,7425,7426],{},"Terminer"," ; ",[19,7429,4893],{}," les abandonne.",[10,7432,7433],{},"Étalonnez un calque image ou PDF à partir d’une distance connue :",[261,7435,7436,7450,7456,7459,7462],{},[152,7437,7438,7439,7441,7442,7445,7446,7449],{},"Ouvrez l’étape ",[19,7440,7413],{}," ou choisissez ",[19,7443,7444],{},"Calibrer"," dans la barre d’outils (",[19,7447,7448],{},"Recalibrer"," pour un calque déjà étalonné).",[152,7451,5031,7452,7455],{},[19,7453,7454],{},"Définir la longueur de référence"," et placez deux points sur une distance dont vous connaissez la longueur réelle, par exemple entre deux lignes de cote.",[152,7457,7458],{},"Saisissez la longueur en mètres et vérifiez l’aperçu.",[152,7460,7461],{},"Si nécessaire, alignez le bord de référence horizontalement ou verticalement.",[152,7463,7464,7465,7467],{},"Ne validez avec ",[19,7466,7426],{}," qu’après avoir vérifié le résultat.",[10,7469,7470],{},"Pour un DXF, PlanElec reprend l’échelle de l’unité du dessin. Si le fichier n’indique aucune unité, PlanElec la déduit des dimensions ou vous la demande une fois. La source de l’échelle reste visible dans l’atelier. Étalonnez manuellement si une dimension connue ne correspond pas.",[30,7472,7474],{"id":7473},"continuer-à-dessiner-sur-la-référence","Continuer à dessiner sur la référence",[10,7476,7477,7478,293,7480,7482],{},"Ajustez si besoin l’opacité et le recadrage du calque. Dessinez ensuite les murs extérieurs et intérieurs fermés avec ",[19,7479,4364],{},[19,7481,4367],{},". PlanElec déduit les pièces des contours de murs fermés ; appareils et chemins de câbles s’appuient sur ce graphe de murs modifiable, pas sur les pixels de la référence.",[10,7484,7485],{},"Avant de poursuivre la planification électrique, vérifiez :",[149,7487,7488,7491,7494,7497],{},[152,7489,7490],{},"Une ou plusieurs dimensions connues correspondent-elles à l’échelle définie ?",[152,7492,7493],{},"Le plan est-il correctement tourné et positionné ?",[152,7495,7496],{},"Seuls les calques utiles sont-ils visibles, sans que les cotes ou cartouches ne gênent le travail ?",[152,7498,7499],{},"Les murs extérieurs et intérieurs ont-ils été retracés comme murs PlanElec ?",[10,7501,7502,7503,4014],{},"Pour plusieurs étages, configurez chaque étage séparément. L’alignement entre étages est une opération distincte et ne remplace pas l’étalonnage d’un calque importé ; voir ",[26,7504,4398],{"href":4397},[10,7506,7507],{},[26,7508],{"id":7509},"recognize",[30,7511,7513],{"id":7512},"faire-reconnaître-le-plan-automatiquement","Faire reconnaître le plan automatiquement",[10,7515,7516],{},"Au lieu de redessiner, vous pouvez faire reconnaître murs et pièces à partir d’un plan. Le résultat est une proposition que vous vérifiez avant sa reprise dans l’étage.",[35,7518,7519,7529],{},[38,7520,7521],{},[41,7522,7523,7526],{},[44,7524,7525],{},"Question",[44,7527,7528],{},"Réponse",[54,7530,7531,7547,7555,7563,7576,7588],{},[41,7532,7533,7536],{},[59,7534,7535],{},"Où commencer ?",[59,7537,7538,7539,7541,7542,132,7544],{},"Sur un étage vide avec ",[19,7540,4346],{}," dans la fenêtre de démarrage, ou pour un fichier enregistré dans le panneau ",[19,7543,711],{},[19,7545,7546],{},"Reconnaître le plan",[41,7548,7549,7552],{},[59,7550,7551],{},"Quels fichiers ?",[59,7553,7554],{},"PDF, PNG, JPEG et WebP ; pas de DXF",[41,7556,7557,7560],{},[59,7558,7559],{},"Qu’est-ce qui est reconnu ?",[59,7561,7562],{},"Murs, pièces avec leur surface, portes et fenêtres, ainsi que les symboles d’appareils pris en charge comme prises, interrupteurs et points lumineux",[41,7564,7565,7568],{},[59,7566,7567],{},"Où vérifier ?",[59,7569,4723,7570,7573,7574],{},[19,7571,7572],{},"Reconnaissance"," : pièces, ouvertures, appareils, questions et ",[19,7575,7413],{},[41,7577,7578,7581],{},[59,7579,7580],{},"Quelles conditions ?",[59,7582,7583,7584,7587],{},"Des droits de modification sur le projet, un étage cible vide et une échelle confirmée – sans ",[19,7585,7586],{},"Confirmer l’échelle",", la reprise reste bloquée",[41,7589,7590,7593],{},[59,7591,7592],{},"Qu’est-ce qui n’est pas repris ?",[59,7594,7595],{},"Les circuits, le schéma unifilaire et les symboles impossibles à attribuer",[10,7597,7598,7599],{},"Pour la reconnaissance, la page est transmise à un fournisseur d’IA externe pour analyse ; chaque exécution consomme votre quota IA. Si la reconnaissance ne trouve pas de plan exploitable, le plan est prêt comme calque à redessiner et vous poursuivez comme décrit ci-dessus. Le déroulement complet, avec l’éditeur de correction, est expliqué dans ",[26,7600,4350],{"href":123},[10,7602,7603],{},[26,7604],{"id":7605},"delete",[30,7607,7609],{"id":7608},"supprimer-un-plan-comment-retirer-un-calque","Supprimer un plan : comment retirer un calque ?",[10,7611,7612,7613,7615],{},"Un plan importé (image, page PDF ou DXF, aussi appelé fond de plan ou calque de référence) se supprime dans le panneau ",[19,7614,4996],{},". Les murs, pièces et appareils que vous avez dessinés restent en place ; seule la couche de référence disparaît.",[261,7617,7618,7634,7639],{},[152,7619,7620,7621,7623,7624,7626,7627,7629,7630,7633],{},"Dans le mode ",[19,7622,4073],{},", ouvrez le panneau ",[19,7625,4996],{}," de l’étage courant avec le bouton ",[19,7628,4996],{}," de la barre d’outils (groupe ",[19,7631,7632],{},"Bâtiment et étages",").",[152,7635,7636,7637,4014],{},"Dans la fiche du plan concerné, choisissez l’icône corbeille rouge à côté de ",[19,7638,7266],{},[152,7640,7641,7642,132,7645,4014],{},"Confirmez la boîte de dialogue ",[19,7643,7644],{},"Supprimer l'image ?",[19,7646,7647],{},"Supprimer",[10,7649,7650,7651,7653],{},"La couche est retirée et conservée 7 jours pour restauration ou annulation. Juste après, vous la récupérez avec ",[19,7652,4893],{}," (flèche en haut à droite ou Ctrl+Z, Mac : Cmd+Z). Le panneau n’a pas de corbeille séparée avec un bouton de restauration. Si le plan supprimé était actif, le plan suivant de l’étage devient actif.",[10,7655,7656,7657,7660,7661,7664],{},"Pour simplement ne plus voir le fond de plan, masquez-le avec l’icône œil (",[19,7658,7659],{},"Masquer la couche",") ou réduisez l’",[19,7662,7663],{},"Opacité"," au lieu de le supprimer.",[10,7666,7667,7668,7670,7671,7673,7674,7676,7677,7680],{},"Les ",[19,7669,7384],{}," restent dans le projet lorsque vous supprimez une couche ; le panneau ",[19,7672,4996],{}," ne propose pas de bouton pour les supprimer. Chaque plan téléversé figure aussi dans le panneau ",[19,7675,711],{},". Vous pouvez y supprimer une pièce avec ",[19,7678,7679],{},"Supprimer définitivement"," ; cette action est irréversible.",[35,7682,7683,7693],{},[38,7684,7685],{},[41,7686,7687,7690],{},[44,7688,7689],{},"Que faut-il retirer ?",[44,7691,7692],{},"Où",[54,7694,7695,7705,7716,7725],{},[41,7696,7697,7700],{},[59,7698,7699],{},"Seulement le plan importé d’un étage",[59,7701,7702,7703,4997],{},"Panneau ",[19,7704,4996],{},[41,7706,7707,7710],{},[59,7708,7709],{},"L’étage entier avec toutes ses données",[59,7711,5010,7712,4951,7714],{},[19,7713,5013],{},[19,7715,5016],{},[41,7717,7718,7721],{},[59,7719,7720],{},"Le projet entier de la liste",[59,7722,4931,7723],{},[19,7724,4946],{},[41,7726,7727,7730],{},[59,7728,7729],{},"Tout recommencer à zéro",[59,7731,7732],{},[26,7733,7735],{"href":7734},"\u002Ffr\u002Fhelp\u002Fbien-demarrer#start-over","Recommencer à zéro",[30,7737,7739],{"id":7738},"ce-que-limportation-ne-fait-pas","Ce que l’importation ne fait pas",[10,7741,7742],{},"Une importation manuelle place seulement un calque de référence sous votre dessin. Les pièces n’apparaissent qu’à partir des murs que vous y tracez ou d’une proposition de reconnaissance vérifiée et reprise. Ni l’importation ni la reconnaissance ne déterminent une installation électrique ou ne produisent un relevé officiel. Vérifiez dimensions, tracé des murs et exécution réelle avant de placer des symboles ou d’exporter des documents.",[10,7744,5417,7745,4014],{},[26,7746,7747],{"href":4437},"placer et relier des symboles électriques",{"title":822,"searchDepth":823,"depth":823,"links":7749},[7750,7751,7752,7753,7754,7755,7756,7757],{"id":7210,"depth":823,"text":7211},{"id":7330,"depth":823,"text":7331},{"id":7375,"depth":823,"text":7376},{"id":7396,"depth":823,"text":7397},{"id":7473,"depth":823,"text":7474},{"id":7512,"depth":823,"text":7513},{"id":7608,"depth":823,"text":7609},{"id":7738,"depth":823,"text":7739},"Utilisez une image, un PDF ou un DXF comme référence à l’échelle, alignez le calque et dessinez le plan modifiable par-dessus – ou laissez l’IA proposer murs et pièces.","floorplan-import-calibration","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Ffloorplan-import-calibration-fr.webp",{},5,"\u002Fhelp\u002Ffloorplan-import-calibration.fr","2026-08-21","10 min",{"title":119,"description":7758},"importer-et-etalonner-un-plan","help\u002Ffloorplan-import-calibration.fr",[7770,6028,7308,7771,7772,7773],"importer un plan","étalonnage","échelle","atelier de calque","Hm4NUsd8bHj0DdyocmaiCFeem3JYn45cJFsLqVEby8c",{"id":7776,"title":4438,"body":7777,"category":844,"description":8002,"extension":846,"guideId":8003,"image":8004,"locale":849,"meta":8005,"navigation":851,"order":8006,"path":8007,"publishedAt":7764,"readTime":8008,"seo":8009,"seoTitle":857,"slug":8010,"stem":8011,"tags":8012,"updatedAt":8019,"__hash__":8020},"help\u002Fhelp\u002Fplace-and-connect-symbols.fr.md",{"type":7,"value":7778,"toc":7993},[7779,7786,7791,7798,7802,7807,7821,7824,7828,7838,7848,7851,7855,7861,7883,7887,7897,7914,7919,7923,7926,7929,7932,7956,7959,7963,7977,7983,7985,7989],[10,7780,7781,7782,7785],{},"Un symbole sur le plan décrit d’abord son ",[19,7783,7784],{},"emplacement physique",". Le lien avec la topologie électrique en fait ensuite un récepteur ou équipement attribué à un circuit, un schéma et des documents.",[10,7787,7788],{},[26,7789],{"id":7790},"place",[4534,7792],{":height":7793,":width":7794,"alt":7795,"caption":7796,"src":7797},"51","902","Palette d’outils avec les symboles électriques disponibles pour la pièce choisie.","La palette sert de point de départ ; il faut encore vérifier la position, l’orientation et la variante du symbole.","\u002Fhelp\u002Fworkflows\u002Ffr-device-palette.png",[30,7799,7801],{"id":7800},"placer-les-symboles-depuis-la-palette","Placer les symboles depuis la palette",[10,7803,5432,7804,7806],{},[19,7805,4073],{},", ouvrez la palette d’outils et choisissez une prise, un interrupteur, un luminaire, un appareil fixe, une boîte ou un tableau. Les icônes d’outil sont affichées dans la palette ; leur libellé apparaît au survol.",[261,7808,7809,7812,7815,7818],{},[152,7810,7811],{},"Sélectionnez l’outil du symbole.",[152,7813,7814],{},"Placez les appareils muraux du bon côté du mur. Les prises et interrupteurs s’aimantent aux murs.",[152,7816,7817],{},"Placez les luminaires ou spots libres dans la pièce.",[152,7819,7820],{},"Vérifiez position, orientation et variante de symbole après la pose.",[10,7822,7823],{},"Un symbole ne peut être posé qu’à un emplacement que l’éditeur reconnaît comme valide. L’aperçu montre la géométrie finale avant validation. Corrigez d’abord mur ou pièce si le symbole ne s’aimante pas à l’endroit prévu.",[30,7825,7827],{"id":7826},"créer-des-cadres-communs","Créer des cadres communs",[10,7829,7830,7831,7834,7835,7837],{},"Un groupe d’installation est une combinaison physique avec un cadre commun de deux à cinq postes. Ce n’est ",[19,7832,7833],{},"ni"," une chaîne de commande ",[19,7836,7833],{}," un circuit.",[10,7839,7840,7841,7844,7845,7847],{},"Glissez des appareils compatibles ensemble sur le même côté d’un mur ou démarrez l’outil de cadre. Dans le panneau ",[19,7842,7843],{},"Groupe d’installation",", choisissez horizontal ou vertical et terminez avec ",[19,7846,7426],{},". Déplacer un membre déplace la combinaison.",[10,7849,7850],{},"Interrupteurs, prises standard, prises Ethernet et coaxiales peuvent être groupés. Les prises IP44 restent exclues à cause de leur cadre étanche. Les prises de données passives ne deviennent pas pour autant des récepteurs 230 V.",[30,7852,7854],{"id":7853},"modifier-ou-dissocier-un-cadre-commun","Modifier ou dissocier un cadre commun",[10,7856,7857,7858,7860],{},"Le cadre apparaît au milieu des appareils groupés ; l'appareil de départ ne saute pas vers un autre endroit. Juste après le groupement, un message propose ",[19,7859,4893],{}," pour défaire le groupement en une seule étape.",[10,7862,7863,7864,7867,7868,7871,7872,120,7875,7878,7879,7882],{},"Cliquez sur le cadre commun pour le modifier. Dans le panneau ",[19,7865,7866],{},"Cadre commun",", vous changez l'",[19,7869,7870],{},"Orientation de la plaque de finition"," (horizontale ou verticale) et l'ordre avec ",[19,7873,7874],{},"Position précédente",[19,7876,7877],{},"Position suivante",". Avec ",[19,7880,7881],{},"Dissocier le groupe"," dans la barre d'outils d'un appareil groupé, le cadre se défait : les appareils se retrouvent côte à côte et sont de nouveau modifiables séparément.",[30,7884,7886],{"id":7885},"adapter-la-taille-des-symboles-du-projet","Adapter la taille des symboles du projet",[10,7888,7889,7890,7892,7893,7896],{},"Les symboles des prises, interrupteurs et lampes sont trop grands pour votre plan ? Ouvrez le menu ",[19,7891,7285],{}," dans la barre de gauche et choisissez sous ",[19,7894,7895],{},"Taille des symboles"," une valeur entre 50 % et 150 %. La valeur par défaut est 100 %.",[149,7898,7899,7906,7909],{},[152,7900,7901,7902,7905],{},"Il s'agit d'un ",[19,7903,7904],{},"réglage du projet"," : il s'applique à tout le projet et aussi à l'export du plan de situation, pas seulement à la vue actuelle.",[152,7907,7908],{},"Il met à l'échelle les symboles muraux compacts et les cadres communs. Les positions, les dimensions enregistrées des appareils et le modèle 3D restent inchangés.",[152,7910,7911,7912,4014],{},"Chaque modification est une étape que vous pouvez défaire avec ",[19,7913,4893],{},[10,7915,7916],{},[26,7917],{"id":7918},"topology",[30,7920,7922],{"id":7921},"relier-lappareil-à-la-topologie-électrique","Relier l’appareil à la topologie électrique",[10,7924,7925],{},"Ouvrez les propriétés de l’appareil placé et reliez-le à un nœud compatible de la topologie électrique. Les variantes de prise, interrupteur et luminaire sont traitées comme des familles compatibles. Les boîtes de connexion et de dérivation ne deviennent électriquement effectives que lorsqu’elles sont réellement reliées.",[10,7927,7928],{},"Contrôlez ensuite la liste des composants non reliés. Elle affiche les symboles présents sur le plan mais qui ne font pas encore partie du modèle électrique.",[10,7930,7931],{},"Conservez cette distinction :",[149,7933,7934,7939,7944,7950],{},[152,7935,7936,7938],{},[19,7937,7416],{}," : où se trouve l’appareil sur le plan ?",[152,7940,7941,7943],{},[19,7942,7843],{}," : quels mécanismes partagent un cadre ?",[152,7945,7946,7949],{},[19,7947,7948],{},"Topologie"," : quel nœud électrique appartient à l’appareil ?",[152,7951,7952,7955],{},[19,7953,7954],{},"Circuit"," : quel appareil de protection alimente ce nœud ?",[10,7957,7958],{},"Modifier un cadre ne change ni la fonction de commande ni l’affectation à un circuit. Éditez ensuite la chaîne de commande pour l’éclairage et affectez les appareils à un circuit pour leur alimentation.",[30,7960,7962],{"id":7961},"vérifier-avant-de-poursuivre","Vérifier avant de poursuivre",[149,7964,7965,7968,7971,7974],{},[152,7966,7967],{},"Chaque symbole est à l’emplacement réel prévu.",[152,7969,7970],{},"Les appareils muraux sont alignés du bon côté du mur.",[152,7972,7973],{},"Les combinaisons de cadre correspondent au montage prévu, pas à un câblage supposé.",[152,7975,7976],{},"Tous les appareils électriques sont reliés au bon nœud de topologie.",[10,7978,5417,7979,4014],{},[26,7980,7982],{"href":7981},"\u002Ffr\u002Fhelp\u002Fcommandes-circuits-et-chemins-de-cables","modifier les chaînes de commande, circuits et chemins de câbles",[30,7984,5429],{"id":5428},[10,7986,5432,7987,5435],{},[19,7988,4458],{},[10,7990,7991,4014],{},[26,7992,5440],{"href":4494},{"title":822,"searchDepth":823,"depth":823,"links":7994},[7995,7996,7997,7998,7999,8000,8001],{"id":7800,"depth":823,"text":7801},{"id":7826,"depth":823,"text":7827},{"id":7853,"depth":823,"text":7854},{"id":7885,"depth":823,"text":7886},{"id":7921,"depth":823,"text":7922},{"id":7961,"depth":823,"text":7962},{"id":5428,"depth":823,"text":5429},"Placez les appareils au bon endroit, créez des cadres communs et reliez les symboles électriques à la topologie appropriée.","place-and-connect-symbols","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fplace-and-connect-symbols-fr.webp",{},6,"\u002Fhelp\u002Fplace-and-connect-symbols.fr","8 min",{"title":4438,"description":8002},"placer-et-relier-des-symboles-electriques","help\u002Fplace-and-connect-symbols.fr",[8013,8014,8015,8016,8017,8018],"symboles électriques","prises","interrupteurs","luminaires","cadres","topologie","2026-10-13","8gq5sH47T3-ic0Ej4xIAwqzONcAT0UH9RFVaEP--3R4",{"id":8022,"title":8023,"body":8024,"category":5452,"description":8147,"extension":846,"guideId":8148,"image":8149,"locale":849,"meta":8150,"navigation":851,"order":8151,"path":8152,"publishedAt":7764,"readTime":855,"seo":8153,"seoTitle":857,"slug":8154,"stem":8155,"tags":8156,"updatedAt":8163,"__hash__":8164},"help\u002Fhelp\u002Fswitch-chains-circuits-cable-routes.fr.md","Commandes, circuits et chemins de câbles",{"type":7,"value":8025,"toc":8141},[8026,8039,8044,8048,8054,8057,8060,8064,8071,8075,8084,8087,8090,8095,8097,8101,8114,8117,8120,8124,8138],[10,8027,8028,8029,331,8032,331,8035,8038],{},"Ces trois outils répondent à des questions différentes : ",[19,8030,8031],{},"quel interrupteur commande quel luminaire ?",[19,8033,8034],{},"Quel circuit alimente quel appareil ?",[19,8036,8037],{},"Où le câble passe-t-il physiquement ?"," Modifiez-les dans cet ordre pour garder un plan techniquement traçable.",[10,8040,8041],{},[26,8042],{"id":8043},"switch-chains",[30,8045,8047],{"id":8046},"relier-interrupteurs-et-luminaires-dans-une-chaîne","Relier interrupteurs et luminaires dans une chaîne",[10,8049,5031,8050,8053],{},[19,8051,8052],{},"Chaîne de commande"," dans le plan. L’outil relie les interrupteurs et les luminaires qu’ils commandent dans un ordre logique. PlanElec peut proposer une chaîne pour des interrupteurs et luminaires libres d’une même pièce ; vérifiez toujours la proposition par rapport à la commande prévue.",[10,8055,8056],{},"Pour une chaîne manuelle, sélectionnez délibérément les appareils participants. Une chaîne valide comporte au moins un interrupteur et un luminaire. Un appareil ne peut appartenir à plusieurs chaînes à la fois. Sur plusieurs étages, la chaîne reste commune au projet ; chaque étage ne montre que ses tronçons locaux et marqueurs de continuité.",[10,8058,8059],{},"Fonction de commande et nombre de pôles sont des réglages distincts. L’application peut déduire une commande simple, va-et-vient ou permutation de la chaîne ; vous choisissez explicitement le nombre de pôles. Un double allumage est un appareil physique unique à deux canaux : affectez chaque luminaire consciemment au canal A ou B.",[10,8061,8062],{},[26,8063],{"id":5464},[4534,8065],{":height":8066,":width":8067,"alt":8068,"caption":8069,"src":8070},"149","598","Panneau d’affectation avec un circuit cible sélectionné.","Le panneau applique ensemble les appareils sélectionnés ; l’affectation électrique ne définit pas encore un chemin de câble réel.","\u002Fhelp\u002Fworkflows\u002Ffr-circuit-assignment.png",[30,8072,8074],{"id":8073},"affecter-des-appareils-à-un-circuit-existant","Affecter des appareils à un circuit existant",[10,8076,5031,8077,8080,8081,8083],{},[19,8078,8079],{},"Affecter un circuit",". Dans le panneau, sélectionnez d’abord le circuit cible ou son disjoncteur, puis les appareils, y compris via le sélecteur d’étage. ",[19,8082,7426],{}," applique la sélection ensemble.",[10,8085,8086],{},"Les appareils non encore reliés sont créés comme récepteurs sous le disjoncteur choisi et liés à leur symbole de plan. Lorsqu’un appareil dépend déjà d’un autre disjoncteur, l’application demande une confirmation explicite avant le déplacement. Annuler ne modifie aucune donnée ; l’ensemble de la validation peut être annulé en une étape.",[10,8088,8089],{},"L’affectation au circuit décrit l’appartenance électrique. Elle ne définit pas encore le chemin réel à travers murs, gaines ou étages.",[10,8091,8092],{},[26,8093],{"id":8094},"cable-routes",[4534,8096],{":height":5322,":width":5196,"alt":5323,"caption":5324,"src":5325},[30,8098,8100],{"id":8099},"planifier-et-ajuster-le-chemin-de-câble","Planifier et ajuster le chemin de câble",[10,8102,5262,8103,8105,8106,8109,8110,8113],{},[19,8104,5265],{},". Lorsque des câbles existent dans la topologie, utilisez ",[19,8107,8108],{},"Tout router automatiquement"," pour l’étage actif ou sélectionnez un câble puis ",[19,8111,8112],{},"Router automatiquement",". Le trajet automatique suit autant que possible les murs dessinés ; comparez-le à l’installation prévue.",[10,8115,8116],{},"Sélectionnez une ligne de câble pour l’éditer manuellement. Cliquez sur un segment pour ajouter un point de passage et le déplacer immédiatement ; double-cliquez pour supprimer un point. Échap désélectionne ou quitte le mode. La longueur affichée est utilisée par les listes de matériel, le calcul de chute de tension et les exports : vérifiez donc chaque trajet inhabituel.",[10,8118,8119],{},"Pour un câble entre étages, sélectionnez explicitement un escalier, une gaine ou une colonne montante existante dans le panneau du chemin de câble. PlanElec n’invente pas de liaison verticale. Si un connecteur nécessaire ou des hauteurs fiables manquent, le trajet reste incomplet plutôt que d’afficher une longueur trompeuse.",[30,8121,8123],{"id":8122},"contrôle-final","Contrôle final",[149,8125,8126,8129,8132,8135],{},[152,8127,8128],{},"Vérifiez la chaîne de commande selon la commande voulue, pas seulement la proximité.",[152,8130,8131],{},"Vérifiez circuit, protection et topologie de chaque appareil.",[152,8133,8134],{},"Vérifiez chemin et longueur de câble par rapport au trajet d’installation prévu.",[152,8136,8137],{},"Considérez les propositions automatiques comme une aide de planification modifiable, pas comme une autorisation d’exécution.",[10,8139,8140],{},"Vous pouvez ensuite poursuivre le contrôle du tableau et du schéma unifilaire, puis lancer l’autocontrôle pris en charge.",{"title":822,"searchDepth":823,"depth":823,"links":8142},[8143,8144,8145,8146],{"id":8046,"depth":823,"text":8047},{"id":8073,"depth":823,"text":8074},{"id":8099,"depth":823,"text":8100},{"id":8122,"depth":823,"text":8123},"Séparez la commande d’éclairage, l’affectation aux circuits et le trajet physique du câble, puis utilisez l’outil adapté à chaque étape.","switch-chains-circuits-cable-routes","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fswitch-chains-circuits-cable-routes-fr.webp",{},7,"\u002Fhelp\u002Fswitch-chains-circuits-cable-routes.fr",{"title":8023,"description":8147},"commandes-circuits-et-chemins-de-cables","help\u002Fswitch-chains-circuits-cable-routes.fr",[8157,8158,8159,8160,8161,8162],"chaîne de commande","va-et-vient","circuit","disjoncteur","chemin de câble","longueur de câble","2026-08-30","vvRBvGwAM5v6-e_NUBD13mKYSHBV9GOIik8GMRkHTOM",{"id":8166,"title":8167,"body":8168,"category":5452,"description":8604,"extension":846,"guideId":8605,"image":8328,"locale":849,"meta":8606,"navigation":851,"order":8607,"path":8608,"publishedAt":8609,"readTime":855,"seo":8610,"seoTitle":857,"slug":8611,"stem":8612,"tags":8613,"updatedAt":8617,"__hash__":8618},"help\u002Fhelp\u002Fknx-planning-documentation.fr.md","Planifier le KNX : poussoirs, canaux et quantités",{"type":7,"value":8169,"toc":8591},[8170,8177,8182,8186,8189,8209,8215,8229,8235,8243,8249,8252,8257,8261,8267,8274,8281,8285,8304,8314,8322,8329,8333,8339,8346,8350,8354,8360,8366,8370,8376,8380,8390,8450,8453,8458,8462,8476,8479,8483,8489,8492,8497,8501,8519,8533,8536,8551,8555,8559,8562,8566],[10,8171,8172,8173,8176],{},"Lorsque la planification ",[19,8174,8175],{},"Domotica"," est activée, PlanElec documente modules, canaux, points de commande, touches, lignes de bus et bornes dans un même projet. Les exports comprennent les plans des canaux et des bornes, les fonctions par pièce, la topologie logique, les quantités et un dossier de remise avec rapport d’autocontrôle. Il faut un profil d’automatisation actif et un accès activé pour votre compte. PlanElec prépare les adresses physiques, les adresses de groupe et les types de points de données pour l’import dans ETS ; la planification ne remplace ni la programmation dans ETS, ni une attestation officielle de conformité au RGIE.",[10,8178,8179],{},[26,8180],{"id":8181},"practical-example",[30,8183,8185],{"id":8184},"exemple-pratique-deux-luminaires-commandés-depuis-deux-endroits","Exemple pratique : deux luminaires commandés depuis deux endroits",[10,8187,8188],{},"Cet exemple fictif documente un plafonnier et une applique dans le salon, commandés par deux boutons-poussoirs. Les captures proviennent de l’interface française. Les affectations, le signalement des puissances manquantes et les quantités ont été vérifiés ; les images ne présentent pas un dossier d’installation entièrement validé.",[261,8190,8191,8197,8203],{},[152,8192,8193,8196],{},[19,8194,8195],{},"Profil et appareils :"," choisissez KNX dans les métadonnées du projet. Placez les deux luminaires et deux boutons-poussoirs de la catégorie Points de commande et capteurs sur le plan de position. Donnez-leur des noms distincts. Ajoutez l’alimentation et l’actionneur au tableau.",[152,8198,8199,8202],{},[19,8200,8201],{},"Raccordement électrique :"," dans Installation, vérifiez le circuit, l’alimentation des modules et leur affectation au tableau. Si un luminaire n’est pas disponible dans la liste des récepteurs, vérifiez son raccordement électrique. L’affectation logique au canal ne remplace pas le chemin de protection.",[152,8204,8205,8208],{},[19,8206,8207],{},"Canal :"," affectez les deux luminaires et les deux poussoirs à CH1. L’exemple utilise « Plafonnier salon », « Applique salon », « Poussoir entrée » et « Poussoir canapé ». Les poussoirs utilisent ici le raccordement Bus. Ajoutez une note décrivant la fonction prévue.",[4534,8210],{":height":8211,":width":8212,"alt":8213,"caption":8213,"src":8214},"220","1790","CH1 associe deux luminaires à deux poussoirs. La borne non affectée reste visible. Données fictives.","\u002Fhelp\u002Fknx-example\u002Ffr-04-matrice-affectations.jpg",[261,8216,8217,8223],{"start":7171},[152,8218,8219,8222],{},[19,8220,8221],{},"Données manquantes :"," si la matrice signale une puissance de luminaire manquante, renseignez les caractéristiques réelles de l’appareil. Avec les valeurs fictives de 24 W et 12 W, ce signalement a disparu. Cela ne constitue pas une vérification complète de la compatibilité électrique.",[152,8224,8225,8228],{},[19,8226,8227],{},"Ligne et alimentation :"," affectez les appareils dans Lignes et choisissez explicitement le module d’alimentation de la ligne. Vérifiez ensuite le courant de bus : les contributions inconnues restent des données ouvertes. Une ligne logique ne mesure aucun trajet de câble.",[4534,8230],{":height":8231,":width":8232,"alt":8233,"caption":8233,"src":8234},"1009","2073","La ligne dispose d’une alimentation de 640 mA, mais trois contributions de courant de bus restent inconnues. La consommation n’est donc pas entièrement vérifiée.","\u002Fhelp\u002Fknx-example\u002Ffr-05-ligne-alimentation.jpg",[261,8236,8237],{"start":8006},[152,8238,8239,8242],{},[19,8240,8241],{},"Quantités :"," ouvrez Export → Domotique et téléchargez les Quantités domotiques en brouillon. Comparez le résultat aux appareils prévus. L’export vérifié contient une alimentation, un actionneur et deux poussoirs. Les deux luminaires ne figurent pas dans cette liste domotique ; complétez-la avec le reste de votre relevé de matériel. Cet exemple ne fournit ni métrés de câbles ni références de commande constructeur.",[4534,8244],{":height":8245,":width":8246,"alt":8247,"caption":8247,"src":8248},"1600","1132","PDF réellement exporté : une alimentation, un actionneur et deux poussoirs. Le filigrane BROUILLON indique le statut du document ; ce n’est pas une attestation.","\u002Fhelp\u002Fknx-example\u002Ffr-06-quantites.png",[10,8250,8251],{},"Pour les documents destinés au contrôle, vérifiez également le plan de position, les repères, le schéma unifilaire complet et les points ouverts de l’export. La liste de quantités présentée ici ne confirme pas ces étapes. Les sections suivantes précisent les documents disponibles et leur statut.",[10,8253,8254],{},[26,8255],{"id":8256},"activate",[30,8258,8260],{"id":8259},"comment-activer-la-planification-domotique","Comment activer la planification domotique ?",[10,8262,8263,8264,8266],{},"Ouvrez les métadonnées du projet et choisissez le profil d’automatisation approprié, par exemple KNX. Les profils déterminent les appareils et raccordements proposés. L’espace ",[19,8265,8175],{}," apparaît lorsque l’accès est activé. S’il manque, la fonction n’est pas disponible pour ce projet ou ce compte ; sélectionner un profil ne suffit pas à ouvrir l’accès.",[10,8268,8269,8270,8273],{},"Le passage entre profils actifs conserve les affectations existantes. En revanche, confirmer ",[19,8271,8272],{},"Aucune domotique"," supprime le document logique de planification Domotica et ses affectations d’automatisation ; les appareils déjà placés restent présents. Lisez la confirmation avant de retirer le profil et vérifiez les appareils et raccordements conservés après un changement. Les caractéristiques inconnues restent inconnues et doivent être vérifiées sur le produit réel.",[10,8275,8276,8278],{},[26,8277],{"id":4406},[26,8279],{"id":8280},"controls",[30,8282,8284],{"id":8283},"comment-documenter-les-boutons-poussoirs-et-leurs-touches","Comment documenter les boutons-poussoirs et leurs touches ?",[10,8286,8287,8288,8291,8292,8295,8296,8299,8300,8303],{},"Placez les appareils de ",[19,8289,8290],{},"Points de commande et capteurs"," sur le plan. Sélectionnez un appareil et utilisez ",[19,8293,8294],{},"Configurer le point de commande",". Indiquez le ",[19,8297,8298],{},"Raccordement"," réel et vérifiez la ",[19,8301,8302],{},"Classe de tension",". Cette dernière est une donnée de planification, pas une preuve électrique.",[10,8305,5432,8306,8309,8310,8313],{},[19,8307,8308],{},"Affectation des touches \u002F entrées",", associez les touches documentées aux canaux. Un point de commande peut agir sur plusieurs canaux ; plusieurs points peuvent partager un canal. Une affectation sans numéro de touche reste valable, mais la liste des fonctions indique ",[19,8311,8312],{},"Touche non documentée",". RF\u002FIP est représenté comme une liaison sans fil et ne crée aucun trajet de câble physique.",[10,8315,8316,8319],{},[26,8317],{"id":8318},"modules",[26,8320],{"id":8321},"channels",[4534,8323],{":height":8324,":width":8325,"alt":8326,"caption":8327,"src":8328},"510","952","Matrice des canaux avec une seule carte CH1 pour un plafonnier et une entrée de bouton-poussoir, la pièce et la protection, avec une borne vide.","La carte documente CH1 avec le plafonnier, l’entrée du bouton-poussoir, la pièce et la protection ; la borne vide reste visible comme donnée de planification ouverte.","\u002Fhelp\u002Fworkflows\u002Ffr-domotica-channels.png",[30,8330,8332],{"id":8331},"comment-créer-la-fiche-des-canaux-pour-la-porte-du-tableau","Comment créer la fiche des canaux pour la porte du tableau ?",[10,8334,8335,8336,8338],{},"Placez les modules appropriés dans le tableau et ajoutez leurs canaux. La matrice de ",[19,8337,8175],{}," relie chaque canal à ses récepteurs et points de commande. Choisissez des noms compréhensibles et ajoutez des notes si nécessaire. Les affectations multiples sont conservées intégralement ; leur lien logique ne remplace ni un chemin de protection ni un trajet de câble documenté.",[10,8340,8341,8342,8345],{},"Le ",[19,8343,8344],{},"Plan des canaux"," reprend les mêmes données et tris : tableau, module, canal, récepteur, pièce, protection, borne, point de commande et note. Dans l’export, choisissez le tableau et triez par module, protection, pièce ou borne. Le PDF A4 paysage sert de fiche de porte ; le CSV permet une reprise des données. Une case vide signifie une information manquante, pas la confirmation qu’un élément est inutile.",[10,8347,8348],{},[26,8349],{"id":4500},[30,8351,8353],{"id":8352},"comment-intégrer-les-lignes-et-les-bornes","Comment intégrer les lignes et les bornes ?",[10,8355,5432,8356,8359],{},[19,8357,8358],{},"Lignes",", affectez modules et points de commande aux lignes de bus prévues, puis documentez alimentations et coupleurs éventuels. Les courants connus et les contributions inconnues sont séparés. La topologie représente ces relations logiques ; ses traits ne sont pas des trajets mesurés de câbles de bus.",[10,8361,5432,8362,8365],{},[19,8363,8364],{},"Plan des borniers",", sélectionnez un tableau et renseignez borniers, numéros, types, destinations et pontages manuels. Le préremplissage exige une action explicite. Les bornes enregistrées alimentent la matrice et l’export ; les lignes du PDF ne modifient pas la numérotation du projet. Ce document n’est pas un schéma de câblage conducteur par conducteur.",[10,8367,8368],{},[26,8369],{"id":4526},[4534,8371],{":height":8372,":width":8325,"alt":8373,"caption":8374,"src":8375},"141","Options d’export Domotica pour le coffret, le tri, la version et le statut brouillon ou final.","Ces commandes définissent le périmètre et le statut de l’export Domotica ; elles ne confirment ni des documents complets ni un contrôle réussi.","\u002Fhelp\u002Fworkflows\u002Ffr-domotica-export.png",[30,8377,8379],{"id":8378},"que-contient-le-dossier-de-remise-domotique","Que contient le dossier de remise domotique ?",[10,8381,8382,8383,8385,8386,8389],{},"Ouvrez l’export, puis ",[19,8384,4286],{},". Choisissez tableau, tri, version et statut. Chaque carte propose aperçu et PDF ; les plans des canaux et des bornes proposent aussi le CSV, et la topologie le SVG. ",[19,8387,8388],{},"Télécharger le dossier domotique"," rassemble les six types de documents après une page de garde.",[35,8391,8392,8401],{},[38,8393,8394],{},[41,8395,8396,8398],{},[44,8397,5500],{},[44,8399,8400],{},"Contenu et limite",[54,8402,8403,8410,8418,8426,8434,8442],{},[41,8404,8405,8407],{},[59,8406,8344],{},[59,8408,8409],{},"Toutes les affectations des tableaux choisis, A4 paysage",[41,8411,8412,8415],{},[59,8413,8414],{},"Plan des bornes",[59,8416,8417],{},"Bornes, destinations et pontages documentés, A4 paysage",[41,8419,8420,8423],{},[59,8421,8422],{},"Fonctions par pièce",[59,8424,8425],{},"Touches et récepteurs en langage courant ; fonctions prévues, sans validation de la programmation",[41,8427,8428,8431],{},[59,8429,8430],{},"Diagramme de topologie",[59,8432,8433],{},"Lignes logiques de tout le projet, également en SVG complet ; les grands diagrammes PDF utilisent des pages qui se chevauchent",[41,8435,8436,8439],{},[59,8437,8438],{},"Quantités domotiques",[59,8440,8441],{},"Nombre de modules, alimentations, points de commande et tronçons de câble de signal existants ; sans prix ni mètres estimés",[41,8443,8444,8447],{},[59,8445,8446],{},"Rapport de conformité avec domotique",[59,8448,8449],{},"Constats et limites de l’autocontrôle existant ; l’absence de contrôle est signalée explicitement",[10,8451,8452],{},"Le choix du tableau limite les plans des canaux, des bornes et des fonctions. Topologie, quantités et rapport couvrent tout le projet. Les fonctions sont regroupées selon la pièce du point de commande ; les récepteurs peuvent se trouver ailleurs.",[10,8454,8455],{},[26,8456],{"id":8457},"readiness",[30,8459,8461],{"id":8460},"quand-puis-je-choisir-final","Quand puis-je choisir FINAL ?",[10,8463,8464,8467,8468,8471,8472,8475],{},[19,8465,8466],{},"BROUILLON"," reste disponible lorsque des données existent, avec un filigrane sur chaque page PDF et dans le SVG. Le CSV commence par une ligne de statut et de métadonnées. ",[19,8469,8470],{},"FINAL"," exige que les conditions de préparation à l’export soient remplies. L’interface énumère les points ouverts et propose ",[19,8473,8474],{},"Traiter le prochain point ouvert",". Une modification du projet peut bloquer à nouveau l’export final.",[10,8477,8478],{},"L’autocontrôle domotique distingue constats, données manquantes et vérifications explicitement non exécutées. Une puissance ou un courant nominal inconnu ne constitue pas un contrôle réussi. Même un document final n’est pas une attestation officielle de conformité au RGIE. Consultez la couverture de l’autocontrôle pour connaître ses limites précises.",[30,8480,8482],{"id":8481},"que-signifient-version-date-et-empreinte","Que signifient version, date et empreinte ?",[10,8484,5901,8485,8488],{},[19,8486,8487],{},"Version"," est une référence libre, initialement A. Les métadonnées PDF contiennent projet, périmètre des tableaux, version, date de création et empreinte SHA-256 ; la page de garde du dossier les affiche également. Version, date, statut et empreinte figurent sur chaque page PDF. Les données et la langue sont figées au démarrage. Une modification du projet ou des options invalide un aperçu ouvert.",[10,8490,8491],{},"L’empreinte identifie les données et options de l’export. Ce n’est ni une signature, ni l’empreinte du PDF terminé, ni une confirmation d’archivage. Conservez le document effectivement remis.",[10,8493,8494],{},[26,8495],{"id":8496},"ets",[30,8498,8500],{"id":8499},"comment-préparer-limport-dans-ets","Comment préparer l’import dans ETS ?",[10,8502,8503,8504,8507,8508,8511,8512,17,8515,8518],{},"Dans l’onglet Domotique, ouvrez la vue ",[19,8505,8506],{},"Adresses"," et choisissez la structure des adresses de groupe : ",[19,8509,8510],{},"Corps de métier \u002F étage \u002F objet"," (par défaut, p. ex. 1\u002F1\u002F1 = éclairage, rez-de-chaussée, premier objet) ou ",[19,8513,8514],{},"Étage \u002F corps de métier \u002F objet",[19,8516,8517],{},"Proposer les adresses"," attribue en une seule étape annulable :",[149,8520,8521,8524,8527],{},[152,8522,8523],{},"les adresses physiques par ligne KNX à partir de la zone et de la ligne : coupleur de ligne x.y.0, actionneurs à partir de x.y.1 dans l’ordre du tableau, puis points de commande bus par pièce ; les alimentations ne reçoivent pas d’adresse,",[152,8525,8526],{},"des adresses de groupe à trois niveaux avec un type de point de données par canal : commutation et état 1.001, variation 3.007 et 5.001, volets 1.008, 1.007 et 5.001, chauffage 9.001, 5.001 et 20.102,",[152,8528,8529,8530,4014],{},"une adresse de groupe (17.001) par scène et une par fonction centrale de la vue ",[19,8531,8532],{},"Fonctions",[10,8534,8535],{},"Vous pouvez modifier chaque adresse. Une adresse modifiée ou verrouillée avec le cadenas est conservée par chaque nouvelle proposition. L’autocontrôle signale les adresses en double comme conflit.",[10,8537,3977,8538,8540,8541,8540,8543,8546,8547,8550],{},[19,8539,3930],{}," › ",[19,8542,4286],{},[19,8544,8545],{},"Préparation ETS",", téléchargez les adresses de groupe en CSV (format ETS « 3\u002F1 » avec groupe principal, intermédiaire et sous-groupe) ou en XML et importez-les dans ETS via ",[19,8548,8549],{},"Importer des adresses de groupe",". La liste des adresses physiques en CSV aide à créer et programmer les appareils. Vérifiez les adresses importées dans ETS ; les appareils, paramètres et liaisons aux objets de communication s’y créent.",[10,8552,8553],{},[26,8554],{"id":180},[30,8556,8558],{"id":8557},"quelles-sont-les-limites-de-cette-documentation","Quelles sont les limites de cette documentation ?",[10,8560,8561],{},"PlanElec propose des adresses KNX et exporte les adresses de groupe pour l’import dans ETS, mais ne crée pas de fichier projet ETS, ne choisit pas de base de données produits, ne lie pas les objets de communication et ne programme pas les appareils. Lignes logiques, affectations des touches, budgets de bus et plans des bornes ne prouvent ni programmation réelle, ni diagnostic du bus, ni isolation, ni compatibilité constructeur. La liste des quantités ne commande aucun produit. Le rapport expose son périmètre limité ; l’examen professionnel de l’installation réelle reste nécessaire.",[30,8563,8565],{"id":8564},"guides-liés","Guides liés",[149,8567,8568,8574,8578,8582,8586],{},[152,8569,8570],{},[26,8571,8573],{"href":8572},"\u002Ffr\u002Fhelp\u002Fplanifier-une-installation-knx-et-preparer-ets","Planifier et documenter une installation domotique",[152,8575,8576],{},[26,8577,8023],{"href":7981},[152,8579,8580],{},[26,8581,4438],{"href":4437},[152,8583,8584],{},[26,8585,4615],{"href":4614},[152,8587,8588],{},[26,8589,8590],{"href":4520},"Ce que vérifie l’autocontrôle RGIE",{"title":822,"searchDepth":823,"depth":823,"links":8592},[8593,8594,8595,8596,8597,8598,8599,8600,8601,8602,8603],{"id":8184,"depth":823,"text":8185},{"id":8259,"depth":823,"text":8260},{"id":8283,"depth":823,"text":8284},{"id":8331,"depth":823,"text":8332},{"id":8352,"depth":823,"text":8353},{"id":8378,"depth":823,"text":8379},{"id":8460,"depth":823,"text":8461},{"id":8481,"depth":823,"text":8482},{"id":8499,"depth":823,"text":8500},{"id":8557,"depth":823,"text":8558},{"id":8564,"depth":823,"text":8565},"Affecter deux luminaires et deux poussoirs, documenter alimentation et ligne de bus, puis exporter une première liste de matériel avec un exemple illustré.","knx-planning-documentation",{},8,"\u002Fhelp\u002Fknx-planning-documentation.fr","2026-09-12",{"title":8167,"description":8604},"planifier-et-documenter-le-knx","help\u002Fknx-planning-documentation.fr",[8614,7060,8615,8616,5152,4526,6102],"KNX","bouton-poussoir","actionneur","2026-11-03","g8_uIfSVd7nZtu5rtTfksqVIqVRVw9ljM0Mt1ArOw5c",{"id":8620,"title":4495,"body":8621,"category":844,"description":9120,"extension":846,"guideId":9121,"image":9122,"locale":849,"meta":9123,"navigation":851,"order":9124,"path":9125,"publishedAt":9126,"readTime":855,"seo":9127,"seoTitle":857,"slug":9128,"stem":9129,"tags":9130,"updatedAt":9133,"__hash__":9134},"help\u002Fhelp\u002Finstallation-topology.fr.md",{"type":7,"value":8622,"toc":9106},[8623,8628,8631,8635,8657,8660,8663,8667,8718,8723,8727,8748,8751,8758,8762,8769,8786,8791,8798,8802,8805,8841,8856,8861,8865,8868,8871,8876,8881,8885,8888,8934,8939,8944,8948,8965,8972,8979,8984,8987,8991,9029,9032,9036,9040,9043,9046,9051,9056,9060,9065,9070,9076,9083,9092,9096,9099],[10,8624,5432,8625,8627],{},[19,8626,4458],{},", vous planifiez quelle protection alimente chaque circuit et ses récepteurs. Vous utilisez les appareils déjà présents sur le plan. Il n’est pas encore nécessaire de choisir un coffret ni des emplacements de modules. Vous formez ensuite les tableaux secondaires, détaillez leur implantation et vérifiez le schéma unifilaire qui en découle.",[10,8629,8630],{},"Ce guide suit une maison fictive dans un seul fichier projet. Les images montrent de vraies vues de ce projet dans l’application. Cet ordre facilite la prise en main ; les projets existants et d’autres points de départ restent possibles. Une vue de planification ou un brouillon exporté ne confirme pas la sécurité électrique d’une installation.",[30,8632,8634],{"id":8633},"démarrage-rapide-du-tableau-à-la-topologie","Démarrage rapide : du tableau à la topologie",[261,8636,8637,8640,8648,8654],{},[152,8638,8639],{},"Placez les récepteurs et un tableau sur le plan.",[152,8641,8642,8643,8645,8646,4014],{},"Sélectionnez le tableau et ",[19,8644,4461],{},". Cette action est également disponible dans ",[19,8647,4458],{},[152,8649,8650,8651,8653],{},"Vérifiez le tableau cible, les nouveaux circuits, les protections et l’espace nécessaire. ",[19,8652,4465],{}," complète le projet et ouvre la topologie du tableau.",[152,8655,8656],{},"Ouvrez la vue du tableau pour vérifier la disposition préparée.",[10,8658,8659],{},"Tous les récepteurs non affectés, sans attribution à un autre tableau, sont pris en compte. Les circuits, les données de câbles et les positions existants sont conservés. Une enveloppe est proposée pour un tableau non configuré ; le manque de place dans une enveloppe existante est signalé. Les appareils nécessitant une planification manuelle et les données d’alimentation manquantes restent ouverts. Une seule annulation revient à l’état précédent. Si le projet change, vérifiez la proposition actualisée avant de l’appliquer. La prévisualisation liste chaque attribution prévue par pièce avec circuit, protection et différentiel. Un circuit vide dont le nom correspond au récepteur est réutilisé au lieu d’ajouter une protection supplémentaire.",[10,8661,8662],{},"Les sections suivantes expliquent la modification manuelle et la vérification de l’installation.",[30,8664,8666],{"id":8665},"quel-est-le-rôle-de-chaque-vue","Quel est le rôle de chaque vue ?",[35,8668,8669,8679],{},[38,8670,8671],{},[41,8672,8673,8676],{},[44,8674,8675],{},"Vue",[44,8677,8678],{},"Objet de la planification",[54,8680,8681,8689,8696,8704,8711],{},[41,8682,8683,8686],{},[59,8684,8685],{},"Plan \u002F plan de position",[59,8687,8688],{},"Emplacement des appareils et chemins physiques des câbles",[41,8690,8691,8693],{},[59,8692,4458],{},[59,8694,8695],{},"Alimentation, protections, circuits et limites des tableaux",[41,8697,8698,8701],{},[59,8699,8700],{},"Tableau électrique",[59,8702,8703],{},"Appareils concrets, coffret, rangées et emplacements des modules",[41,8705,8706,8708],{},[59,8707,569],{},[59,8709,8710],{},"Représentation documentaire de la même installation",[41,8712,8713,8715],{},[59,8714,3930],{},[59,8716,8717],{},"Documents issus de la version enregistrée, avec leur état de vérification",[10,8719,8720],{},[26,8721],{"id":8722},"assignment",[30,8724,8726],{"id":8725},"affecter-un-appareil-existant-du-plan","Affecter un appareil existant du plan",[261,8728,8729,8734,8740,8745],{},[152,8730,8731,8732,4014],{},"Placez les appareils sur le plan ou ouvrez un projet existant. Voir ",[26,8733,7747],{"href":4437},[152,8735,8736,8737,8739],{},"Ouvrez ",[19,8738,4458],{},", recherchez l’appareil et sélectionnez-le dans l’arborescence ou la vue graphique.",[152,8741,4017,8742,8744],{},[19,8743,8079],{},", choisissez le circuit existant voulu et confirmez.",[152,8746,8747],{},"Vérifiez le chemin de protection affiché. Le lien vers le plan vous conduit au symbole associé.",[10,8749,8750],{},"Vous affectez le même appareil. Ne créez pas un second récepteur pour le faire apparaître dans le schéma. Dans l’exemple, la prise existante du séjour est affectée à son circuit.",[4534,8752],{":height":8753,":width":8754,"alt":8755,"caption":8756,"src":8757},"900","1440","La même prise du séjour sur le plan après son affectation électrique.","Le symbole du plan est conservé ; seule son affectation électrique a été complétée.","\u002Fhelp\u002Finstallation-topology\u002Ffr-01-floorplan-assignment.png",[30,8759,8761],{"id":8760},"déplacer-des-récepteurs-dans-la-liste-des-circuits","Déplacer des récepteurs dans la liste des circuits",[10,8763,8764,8765,8768],{},"La vue ",[19,8766,8767],{},"Circuits"," affiche, par tableau et par différentiel, chaque circuit terminal avec ses récepteurs, la somme des puissances saisies et la phase. Les récepteurs sans circuit apparaissent en haut.",[261,8770,8771,8778,8781],{},[152,8772,8736,8773,8775,8776,4014],{},[19,8774,4458],{}," et choisissez la vue ",[19,8777,8767],{},[152,8779,8780],{},"Glissez un récepteur sur le circuit voulu. Ses câbles suivent.",[152,8782,8783,8785],{},[19,8784,4893],{}," revient entièrement sur l’étape.",[10,8787,8788,8789,4014],{},"Seuls les éléments raccordés directement au disjoncteur sont déplaçables ; une boîte de dérivation emporte ses récepteurs. Le filtre par pièce n’affiche que les circuits qui alimentent la pièce choisie. Sans souris, sélectionnez le récepteur et utilisez ",[19,8790,8079],{},[4534,8792],{":height":8793,":width":8794,"alt":8795,"caption":8796,"src":8797},"810","1370","Liste des circuits de la maison exemple avec le tableau principal et le tableau de l’étage.","Chaque circuit figure sous son différentiel avec sa désignation, son courant assigné, sa phase et ses récepteurs.","\u002Fhelp\u002Finstallation-topology\u002Ffr-10-circuit-list.png",[30,8799,8801],{"id":8800},"traiter-les-tâches-ouvertes","Traiter les tâches ouvertes",[10,8803,8804],{},"Sans sélection, le panneau latéral liste les tâches ouvertes – une ligne par problème, pas par appareil.",[35,8806,8807,8817],{},[38,8808,8809],{},[41,8810,8811,8814],{},[44,8812,8813],{},"Tâche",[44,8815,8816],{},"Solution dans le panneau latéral",[54,8818,8819,8830],{},[41,8820,8821,8824],{},[59,8822,8823],{},"Récepteurs sans circuit",[59,8825,8826,8829],{},[19,8827,8828],{},"Attribuer automatiquement"," ouvre la proposition de la planification automatique",[41,8831,8832,8835],{},[59,8833,8834],{},"Tableau ouvert : raccordé électriquement, mais attribué à aucun tableau",[59,8836,8837,8840],{},[19,8838,8839],{},"Former un tableau"," ouvre la prévisualisation de toute la chaîne depuis son premier appareil",[10,8842,8843,8844,8847,8848,8851,8852,8855],{},"En dessous figurent les actions pour toute l’installation. ",[19,8845,8846],{},"Équilibrer les phases"," répartit mieux les circuits monophasés sur L1–L3 en raccordement triphasé, sans déplacer les positions des modules. ",[19,8849,8850],{},"Compléter les câbles manquants"," crée uniquement les câbles manquants ; les câbles existants et leurs données restent inchangés. ",[19,8853,8854],{},"Calculer les tracés de câbles"," complète les tracés manquants sur le plan et laisse inchangés les tracés dessinés à la main.",[10,8857,8858],{},[26,8859],{"id":8860},"supply-path",[30,8862,8864],{"id":8863},"lire-le-chemin-complet-dalimentation-et-de-protection","Lire le chemin complet d’alimentation et de protection",[10,8866,8867],{},"Revenez à l’installation. Raccordement réseau, compteur, protections, circuits et récepteurs restent accessibles ensemble. Sélectionnez un récepteur pour voir son chemin vers l’alimentation. Les références d’appareils et de circuits permettent de comparer plan et schéma.",[10,8869,8870],{},"Utilisez la recherche, le dépliage\u002Frepliage et l’arborescence pour les projets importants. Une branche repliée existe toujours. Commandes, fonctions de commutation et affectations de bus sont des relations supplémentaires ; elles ne doivent pas devenir des liaisons d’alimentation arbitraires.",[4534,8872],{":height":8793,":width":8794,"alt":8873,"caption":8874,"src":8875},"Vue d’ensemble de la maison exemple, de l’alimentation aux récepteurs.","La vue d’ensemble reprend les appareils existants du projet.","\u002Fhelp\u002Finstallation-topology\u002Ffr-02-installation-overview.png",[10,8877,8878],{},[26,8879],{"id":8880},"draft",[30,8882,8884],{"id":8883},"continuer-sans-coffret-défini","Continuer sans coffret défini",[10,8886,8887],{},"Un tableau encore à déterminer est un état de projet enregistrable. Enregistrez puis rechargez le projet : l’affectation reste ouverte, sans rattachement automatique à un tableau principal.",[35,8889,8890,8900],{},[38,8891,8892],{},[41,8893,8894,8897],{},[44,8895,8896],{},"État",[44,8898,8899],{},"Étape suivante",[54,8901,8902,8910,8918,8926],{},[41,8903,8904,8907],{},[59,8905,8906],{},"Pas d’affectation électrique",[59,8908,8909],{},"Définir l’alimentation ou le circuit",[41,8911,8912,8915],{},[59,8913,8914],{},"Liaison électrique établie, tableau ouvert",[59,8916,8917],{},"Planifier un groupe physique adapté",[41,8919,8920,8923],{},[59,8921,8922],{},"Tableau défini, implantation ouverte",[59,8924,8925],{},"Vérifier l’alimentation, préciser coffret et modules",[41,8927,8928,8931],{},[59,8929,8930],{},"Modules placés",[59,8932,8933],{},"Vérifier implantation, données électriques et documents",[4534,8935],{":height":8793,":width":8794,"alt":8936,"caption":8937,"src":8938},"Partie électriquement planifiée dont le tableau physique reste à définir.","Une liaison électrique ne signifie pas que l’implantation du coffret est terminée.","\u002Fhelp\u002Finstallation-topology\u002Ffr-03-draft-without-board.png",[10,8940,8941],{},[26,8942],{"id":8943},"distribution-board",[30,8945,8947],{"id":8946},"former-un-tableau-secondaire-à-partir-dune-sélection","Former un tableau secondaire à partir d’une sélection",[261,8949,8950,8953,8959,8962],{},[152,8951,8952],{},"Sélectionnez les protections qui vont ensemble. Utilisez les cases individuelles de l’arborescence ou la sélection multiple de la vue graphique.",[152,8954,4017,8955,8958],{},[19,8956,8957],{},"Former un tableau à partir de la sélection"," et donnez-lui un nom compréhensible.",[152,8960,8961],{},"Lisez la prévisualisation : point d’entrée, modules, récepteurs hors coffret, limites existantes et placements affectés.",[152,8963,8964],{},"Confirmez uniquement une sélection cohérente. En cas de contradiction, l’application indique le motif ; adaptez votre sélection.",[4534,8966],{":height":8967,":width":8968,"alt":8969,"caption":8970,"src":8971},"638","512","Prévisualisation du tableau secondaire étage, de ses modules et des conséquences.","Le cadre de sélection seul ne crée pas une limite de tableau enregistrée.","\u002Fhelp\u002Finstallation-topology\u002Ffr-04-board-preview.png",[10,8973,8974,8975,8978],{},"Après confirmation, les protections appartiennent au nouveau tableau physique. Les prises et luminaires alimentés restent ",[19,8976,8977],{},"hors"," de son cadre. Des tableaux électriquement en aval ne sont pas des coffrets placés les uns dans les autres.",[4534,8980],{":height":8793,":width":8794,"alt":8981,"caption":8982,"src":8983},"Tableau secondaire confirmé avec protections à l’intérieur et récepteurs à l’extérieur.","Appartenir physiquement à un tableau et être alimenté par ce tableau sont deux notions différentes.","\u002Fhelp\u002Finstallation-topology\u002Ffr-05-board-created.png",[10,8985,8986],{},"Vérifiez ensuite l’alimentation : sélectionnez la protection réellement en amont et renseignez les données du câble, notamment nombre de conducteurs, section et longueur. Confirmez explicitement cette liaison. Le regroupement n’invente ni protection ni câble d’alimentation. La planification radiale exige un chemin amont univoque ; les sources locales telles que le photovoltaïque sont traitées séparément.",[30,8988,8990],{"id":8989},"que-changent-les-actions-de-suppression","Que changent les actions de suppression ?",[35,8992,8993,9003],{},[38,8994,8995],{},[41,8996,8997,9000],{},[44,8998,8999],{},"Action",[44,9001,9002],{},"Conséquence",[54,9004,9005,9013,9021],{},[41,9006,9007,9010],{},[59,9008,9009],{},"Dissoudre le regroupement du tableau",[59,9011,9012],{},"Retirer le groupe physique ; les appareils électriques restent disponibles",[41,9014,9015,9018],{},[59,9016,9017],{},"Retirer un placement de module",[59,9019,9020],{},"Libérer sa position dans la rangée ; l’appareil électrique reste présent",[41,9022,9023,9026],{},[59,9024,9025],{},"Supprimer un appareil électrique",[59,9027,9028],{},"Modifier l’objet électrique et les liaisons concernées",[10,9030,9031],{},"Lisez chaque prévisualisation ou confirmation, puis vérifiez les vues concernées. Les modifications associées peuvent être suivies avec annuler\u002Frétablir.",[10,9033,9034],{},[26,9035],{"id":4446},[30,9037,9039],{"id":9038},"détailler-les-modules-et-le-coffret","Détailler les modules et le coffret",[10,9041,9042],{},"Ouvrez le tableau depuis le tableau secondaire sélectionné. Les appareils existants sont repris et les modules non placés restent accessibles. Choisissez les modules concrets, vérifiez leur largeur en unités modulaires (TE) et planifiez les rangées.",[10,9044,9045],{},"La planification du coffret montre le besoin des modules et utilise la réserve ainsi que l’espace pour bornes et accessoires saisis. Vérifiez montage, espace de câblage, dissipation thermique et conditions du fabricant. Avec des modules génériques ou des données manquantes, l’encombrement reste estimatif. Un coffret proposé n’est pas une autorisation d’exécution.",[4534,9047],{":height":8753,":width":8754,"alt":9048,"caption":9049,"src":9050},"Éditeur du tableau secondaire avec ses modules et sa planification de coffret.","L’affectation électrique et la position dans une rangée sont modifiables séparément. Réorganiser une même armoire ne change pas le chemin de protection.","\u002Fhelp\u002Finstallation-topology\u002Ffr-06-cabinet-planning.png",[10,9052,9053],{},[26,9054],{"id":9055},"schema-export",[30,9057,9059],{"id":9058},"vérifier-le-schéma-unifilaire-et-exporter-les-documents","Vérifier le schéma unifilaire et exporter les documents",[10,9061,8736,9062,9064],{},[19,9063,569],{},". Les mêmes récepteurs, protections et tableaux apparaissent dans la vue documentaire. Vérifiez les feuilles par tableau et les renvois. Le schéma est rendu à partir du modèle du projet ; ce n’est pas une capture de l’arborescence.",[4534,9066],{":height":8753,":width":8754,"alt":9067,"caption":9068,"src":9069},"Schéma unifilaire dérivé du modèle commun du projet.","Déplacer ou agrandir la vue topologique ne modifie pas les coordonnées du PDF.","\u002Fhelp\u002Finstallation-topology\u002Ffr-07-derived-schema.png",[10,9071,9072,9073,9075],{},"Passez à ",[19,9074,3930],{},", vérifiez la version enregistrée et choisissez les documents. Les affectations, données de câbles et vérifications ouvertes restent visibles. Un téléchargement proposé comme brouillon reste un brouillon. La génération de documents ne remplace ni la vérification professionnelle ni le contrôle officiel.",[4534,9077],{":height":9078,":width":9079,"alt":9080,"caption":9081,"src":9082},"1273","1800","Document réellement exporté depuis le projet exemple enregistré.","Le document reprend les mêmes appareils. Son statut visible indique l’usage auquel il est destiné.","\u002Fhelp\u002Finstallation-topology\u002Ffr-08-export-result.png",[10,9084,9085,9086,120,9089,4014],{},"Pour poursuivre : ",[26,9087,9088],{"href":4614},"exporter les documents",[26,9090,9091],{"href":4520},"ce que vérifie l’autocontrôle",[30,9093,9095],{"id":9094},"utiliser-une-tablette-un-téléphone-ou-le-clavier","Utiliser une tablette, un téléphone ou le clavier",[10,9097,9098],{},"Sur écran étroit, l’arborescence est privilégiée. Utilisez les cases de sélection et les actions nommées pour l’affectation et les tableaux secondaires. Les flèches déplacent le focus dans l’arbre, Entrée ouvre la sélection et Espace sélectionne un élément pour la sélection multiple.",[4534,9100],{":height":9101,":width":9102,"alt":9103,"caption":9104,"src":9105},"844","390","Arborescence mobile avec les mêmes appareils et les actions accessibles.","L’arborescence et la vue graphique modifient le même projet.","\u002Fhelp\u002Finstallation-topology\u002Ffr-09-mobile-tree.png",{"title":822,"searchDepth":823,"depth":823,"links":9107},[9108,9109,9110,9111,9112,9113,9114,9115,9116,9117,9118,9119],{"id":8633,"depth":823,"text":8634},{"id":8665,"depth":823,"text":8666},{"id":8725,"depth":823,"text":8726},{"id":8760,"depth":823,"text":8761},{"id":8800,"depth":823,"text":8801},{"id":8863,"depth":823,"text":8864},{"id":8883,"depth":823,"text":8884},{"id":8946,"depth":823,"text":8947},{"id":8989,"depth":823,"text":8990},{"id":9038,"depth":823,"text":9039},{"id":9058,"depth":823,"text":9059},{"id":9094,"depth":823,"text":9095},"Affectez les appareils existants du plan, vérifiez les protections et détaillez votre installation en tableaux, coffrets et schéma unifilaire.","installation-topology","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Finstallation-topology.webp",{},9,"\u002Fhelp\u002Finstallation-topology.fr","2026-09-13",{"title":4495,"description":9120},"planifier-installation-et-tableaux-secondaires","help\u002Finstallation-topology.fr",[4458,7948,9131,9132,569],"Tableau secondaire","Coffret","2026-10-07","mu0J5WiEZf-T-_A_c1Xamq85yw1LHOdbOylGyoxm8pU",{"id":9136,"title":4731,"body":9137,"category":844,"description":9484,"extension":846,"guideId":9485,"image":9486,"locale":849,"meta":9487,"navigation":851,"order":9488,"path":9489,"publishedAt":9490,"readTime":7174,"seo":9491,"seoTitle":857,"slug":9492,"stem":9493,"tags":9494,"updatedAt":6105,"__hash__":9498},"help\u002Fhelp\u002Fstudio-aktivitaet-assistent.fr.md",{"type":7,"value":9138,"toc":9474},[9139,9144,9148,9159,9169,9172,9176,9179,9185,9229,9236,9240,9263,9269,9273,9280,9299,9305,9359,9363,9368,9372,9377,9439,9442,9445,9449,9456,9463,9467],[10,9140,9141,9143],{},[19,9142,4726],{}," réunit vos conversations et demandes à l’assistant PlanElec ainsi que les modifications confirmées du projet. L’assistant est disponible pour tout utilisateur connecté : il exécute les instructions directement dans le projet, contrôle chaque modification avec l’autocontrôle RGIE et la garde prête comme une seule étape d’annulation. Les modifications confirmées de l’équipe apparaissent dès que l’historique du projet est activé pour votre compte.",[30,9145,9147],{"id":9146},"comment-ouvrir-le-panneau","Comment ouvrir le panneau ?",[10,9149,9150,9151,9154,9155,9158],{},"Ouvrez un projet dans le studio. Utilisez le bouton en bas de la barre latérale des modes (rail), le bouton avec le robot à droite dans l’en-tête ou ",[19,9152,9153],{},"⌘J"," sur Mac \u002F ",[19,9156,9157],{},"Ctrl+J",". Le panneau s’ouvre à côté de l’espace de travail ; sur les écrans étroits, il apparaît sous forme de volet.",[10,9160,9161,9164,9165,9168],{},[19,9162,9163],{},"⌘K \u002F Ctrl+K"," ouvre la recherche de commandes. Ensuite, ",[19,9166,9167],{},"Envoyer à l’assistant : « … »"," apparaît lorsque la recherche ne trouve aucun résultat ou contient au moins quatre mots. Sélectionner cette option ouvre le panneau et envoie immédiatement le texte comme demande.",[10,9170,9171],{},"L’historique accessible depuis le menu du projet ou le bouton d’historique ouvre l’activité de l’équipe dans le studio. En dehors du studio, il ouvre une fenêtre d’historique séparée.",[30,9173,9175],{"id":9174},"que-montrent-les-filtres","Que montrent les filtres ?",[10,9177,9178],{},"La chronologie regroupe les entrées par jour, du plus récent au plus ancien. À l’intérieur d’une journée, les entrées suivent l’ordre chronologique. L’en-tête indique aussi le nombre de membres en ligne.",[10,9180,9181,9182,4014],{},"Chaque modification d’un membre indique qui a modifié le projet : avatar et nom, la modification et l’heure. Un membre qui a quitté le projet apparaît comme ",[19,9183,9184],{},"Ancien membre",[35,9186,9187,9197],{},[38,9188,9189],{},[41,9190,9191,9194],{},[44,9192,9193],{},"Filtre",[44,9195,9196],{},"Contenu",[54,9198,9199,9209,9219],{},[41,9200,9201,9206],{},[59,9202,9203],{},[19,9204,9205],{},"Tout",[59,9207,9208],{},"Modifications du projet chargées, messages et actions de l’assistant.",[41,9210,9211,9216],{},[59,9212,9213],{},[19,9214,9215],{},"Équipe",[59,9217,9218],{},"Toutes les modifications chargées, y compris celles réalisées par l’assistant pour d’autres membres.",[41,9220,9221,9226],{},[59,9222,9223],{},[19,9224,9225],{},"Assistant",[59,9227,9228],{},"Conversations et actions de l’assistant, ainsi que les modifications enregistrées dont l’origine est l’assistant.",[10,9230,9231,9232,9235],{},"La barre de filtres apparaît si l’historique et l’assistant sont tous deux disponibles. Si un seul est activé, son contenu s’affiche directement. Vous pouvez charger les modifications plus anciennes. Lorsqu’une cible est disponible, ",[19,9233,9234],{},"Afficher"," mène à son état actuel, pas à une copie historique du projet.",[30,9237,9239],{"id":9238},"comment-soumettre-et-vérifier-une-demande","Comment soumettre et vérifier une demande ?",[261,9241,9242,9245,9251,9254],{},[152,9243,9244],{},"Saisissez votre question ou décrivez la modification souhaitée dans le champ de texte.",[152,9246,5031,9247,9250],{},[19,9248,9249],{},"Envoyer le message"," ou appuyez sur Entrée. Maj+Entrée ajoute une nouvelle ligne.",[152,9252,9253],{},"Vérifiez la réponse et les cartes d’action : elles indiquent l’outil, le statut et la personne à l’origine de la demande.",[152,9255,9256,9257,293,9260,4014],{},"Si une action exige une confirmation, examinez-la puis choisissez ",[19,9258,9259],{},"Confirmer et exécuter",[19,9261,9262],{},"Refuser et annuler l’exécution",[10,9264,9265,9266,9268],{},"Pendant l’exécution d’une tâche, le bouton d’envoi devient ",[19,9267,4893],{}," (icône carrée). Il arrête la tâche en cours ; les modifications déjà effectuées ne sont pas automatiquement annulées.",[30,9270,9272],{"id":9271},"comment-dicter-une-demande","Comment dicter une demande ?",[10,9274,9275,9276,9279],{},"Lorsque votre navigateur prend en charge l’enregistrement par micro, le bouton micro ",[19,9277,9278],{},"Dicter"," se trouve à droite de la barre de saisie. La première fois, votre navigateur demande l’autorisation d’utiliser le micro pour PlanElec.",[261,9281,9282,9287,9290,9296],{},[152,9283,9284,9285,4014],{},"Placez le curseur à l’endroit du champ de saisie où le texte doit apparaître, puis choisissez ",[19,9286,9278],{},[152,9288,9289],{},"Énoncez votre demande dans la langue de l’interface, par exemple : « Hall, mur nord : trois prises, à 30 centimètres du sol fini. » Des barres de niveau et un chronomètre indiquent l’enregistrement.",[152,9291,5031,9292,9295],{},[19,9293,9294],{},"Utiliser l’enregistrement"," (coche) ou appuyez sur Entrée. Après une courte transcription, le texte reconnu apparaît à la position du curseur.",[152,9297,9298],{},"Vérifiez et corrigez le texte, puis envoyez-le comme d’habitude. Le texte dicté n’est jamais envoyé automatiquement.",[10,9300,9301,9304],{},[19,9302,9303],{},"Abandonner l’enregistrement"," (X) ou Échap termine l’enregistrement sans texte. Un enregistrement s’arrête automatiquement après 2 minutes ; le chronomètre change de couleur dix secondes avant. Si le navigateur bloque le micro, un message apparaît sous le champ de saisie ; autorisez alors l’accès dans les réglages du site de votre navigateur.",[35,9306,9307,9317],{},[38,9308,9309],{},[41,9310,9311,9314],{},[44,9312,9313],{},"Situation",[44,9315,9316],{},"Message sous le champ de saisie",[54,9318,9319,9327,9335,9343,9351],{},[41,9320,9321,9324],{},[59,9322,9323],{},"Accès au micro bloqué",[59,9325,9326],{},"Autoriser l’accès dans les réglages du navigateur",[41,9328,9329,9332],{},[59,9330,9331],{},"Aucun micro trouvé",[59,9333,9334],{},"Brancher un micro ou changer d’appareil",[41,9336,9337,9340],{},[59,9338,9339],{},"Rien n’a été compris",[59,9341,9342],{},"Parler à nouveau, plus distinctement",[41,9344,9345,9348],{},[59,9346,9347],{},"Nombreux enregistrements en peu de temps",[59,9349,9350],{},"Patienter un instant",[41,9352,9353,9356],{},[59,9354,9355],{},"Quota IA insuffisant",[59,9357,9358],{},"La transcription est imputée au quota IA",[30,9360,9362],{"id":9361},"où-vont-mes-données-vocales","Où vont mes données vocales ?",[10,9364,4050,9365,9367],{},[19,9366,9294],{},", votre navigateur envoie l’enregistrement à PlanElec. PlanElec le transmet via le service d’IA OpenRouter au modèle de reconnaissance vocale Scribe d’ElevenLabs et ne reçoit que le texte reconnu. La requête exige des fournisseurs qui ne conservent pas les données et ne les utilisent pas pour l’entraînement. PlanElec ne conserve ni l’enregistrement ni son texte ; seul ce que vous envoyez ensuite comme demande est enregistré. Les enregistrements abandonnés ne quittent pas votre appareil.",[30,9369,9371],{"id":9370},"lassistant-peut-il-placer-des-boîtiers-au-mur-avec-des-cotes-exactes","L’assistant peut-il placer des boîtiers au mur avec des cotes exactes ?",[10,9373,9374,9375,4014],{},"Oui. Une phrase avec la pièce, le mur, la distance et la hauteur suffit, par exemple : « Hall, mur nord : trois prises, 30 cm au-dessus du sol fini, la première à 45 cm de l’angle gauche, entraxe 71 mm ». L’assistant transmet les cotes en mètres ; la position exacte en est calculée. Dans cet exemple, les trois prises partagent un même cadre, avec leurs axes à 0,45 m, 0,521 m et 0,592 m. Vous pouvez taper la phrase ou la prononcer avec ",[19,9376,9278],{},[35,9378,9379,9389],{},[38,9380,9381],{},[41,9382,9383,9386],{},[44,9384,9385],{},"Dans la phrase",[44,9387,9388],{},"Application",[54,9390,9391,9399,9407,9415,9423,9431],{},[41,9392,9393,9396],{},[59,9394,9395],{},"« mur nord », « mur est »",[59,9397,9398],{},"Le mur orienté dans cette direction, vu depuis l’intérieur de la pièce. L’orientation nord définie fait foi ; sans orientation nord, le haut du plan est considéré comme le nord et le résultat le signale.",[41,9400,9401,9404],{},[59,9402,9403],{},"« de l’angle gauche », « de l’angle droit »",[59,9405,9406],{},"La gauche et la droite s’entendent depuis l’intérieur de la pièce, face au mur. La mesure se fait sur la face intérieure depuis l’angle intérieur ; l’épaisseur du mur voisin est donc déjà déduite.",[41,9408,9409,9412],{},[59,9410,9411],{},"« la première à 45 cm », « centre à 1,20 m »",[59,9413,9414],{},"Distance jusqu’au premier axe de boîtier ou jusqu’au centre du cadre.",[41,9416,9417,9420],{},[59,9418,9419],{},"« entraxe 71 mm », « prise double »",[59,9421,9422],{},"Plusieurs boîtiers dans un cadre commun avec un entraxe de 71 mm, cinq au maximum. Tout autre entraxe est refusé.",[41,9424,9425,9428],{},[59,9426,9427],{},"« espacées de 1,5 m »",[59,9429,9430],{},"Des cadres séparés avec cette distance de centre à centre.",[41,9432,9433,9436],{},[59,9434,9435],{},"« 30 cm au-dessus du sol fini »",[59,9437,9438],{},"Hauteur du centre du boîtier, enregistrée comme hauteur de pose propre à l’appareil. Sans hauteur, la hauteur standard du type d’appareil s’applique.",[10,9440,9441],{},"Plusieurs prises dans un même cadre deviennent un seul appareil à plusieurs prises, comme une prise double. Les interrupteurs, prises Ethernet et prises coaxiales dans un même cadre forment un cadre commun. Sont pris en charge les prises, les prises étanches aux projections d’eau, les interrupteurs, les interrupteurs de volet roulant (uniquement seuls) ainsi que les prises Ethernet et coaxiales. Les boutons-poussoirs restent placés un par un.",[10,9443,9444],{},"Si une indication ne convient pas, l’assistant ne place rien et en donne la raison : par exemple lorsque la position tombe dans une porte, qu’un boîtier se trouve déjà à cet endroit à la même hauteur, que la hauteur dépasse celle de la pièce ou que plusieurs murs de la pièce sont orientés dans la même direction. Rien n’est déplacé en silence. Sur demande, l’assistant crée d’abord un aperçu sans rien modifier. La rangée placée constitue une seule étape d’annulation.",[30,9446,9448],{"id":9447},"comment-reconnaître-une-modification-de-lassistant","Comment reconnaître une modification de l’assistant ?",[10,9450,9451,9452,9455],{},"Chaque action de l’agent apparaît avec son demandeur dans le panneau d’activité. Les modifications enregistrées de l’assistant portent une vignette robot et ",[19,9453,9454],{},"Assistant · pour le compte de …"," dans l’historique. Le nom désigne le membre qui a donné la consigne, même si vous consultez les modifications d’un autre membre. Cette indication reste visible avec l’accès à l’historique, même sans accès personnel au chat.",[10,9457,9458,9459,9462],{},"En dehors du studio, une petite icône robot figure à côté de l’acteur dans l’historique. Survolez-la ou donnez-lui le focus au clavier : l’infobulle affiche ",[19,9460,9461],{},"Assistant pour le compte de …",". Les conversations et les actions de consultation ne sont pas des modifications enregistrées du projet.",[30,9464,9466],{"id":9465},"puis-je-annuler-une-action-de-lagent","Puis-je annuler une action de l’agent ?",[10,9468,9469,9470,9473],{},"Les modifications de projet terminées et compatibles proposent ",[19,9471,9472],{},"Annuler la modification"," sur leur carte d’action. Le bouton n’est actif que pour la dernière modification admissible, avec une entrée d’annulation valide et le bon contexte de projet. Les réponses, consultations et actions non compatibles n’offrent pas cette possibilité. Une entrée d’historique seule n’est pas un bouton de restauration. Après l’annulation, vérifiez le statut de l’action et le projet.",{"title":822,"searchDepth":823,"depth":823,"links":9475},[9476,9477,9478,9479,9480,9481,9482,9483],{"id":9146,"depth":823,"text":9147},{"id":9174,"depth":823,"text":9175},{"id":9238,"depth":823,"text":9239},{"id":9271,"depth":823,"text":9272},{"id":9361,"depth":823,"text":9362},{"id":9370,"depth":823,"text":9371},{"id":9447,"depth":823,"text":9448},{"id":9465,"depth":823,"text":9466},"Suivez les modifications du projet et les tâches de l’assistant, identifiez leur demandeur et donnez vos instructions à l’assistant PlanElec avec vos propres mots.","studio-activity-assistant","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fstudio-activity-assistant-fr.webp",{},10,"\u002Fhelp\u002Fstudio-aktivitaet-assistent.fr","2026-09-15",{"title":4731,"description":9484},"studio-activite-assistant","help\u002Fstudio-aktivitaet-assistent.fr",[9495,9496,9225,9497],"Studio","Historique du projet","IA","rwiNH3Yvrnj3RgdcsSt4PpWlFGRPktClRbm1vxvmtY4",{"id":9500,"title":9501,"body":9502,"category":844,"description":9955,"extension":846,"guideId":9956,"image":9957,"locale":849,"meta":9958,"navigation":851,"order":9959,"path":9960,"publishedAt":9961,"readTime":7174,"seo":9962,"seoTitle":9963,"slug":9964,"stem":9965,"tags":9966,"updatedAt":9961,"__hash__":9972},"help\u002Fhelp\u002Ffloor-alignment-building-origin.fr.md","Comment aligner des étages superposés et à quoi sert l’origine du bâtiment ?",{"type":7,"value":9503,"toc":9945},[9504,9522,9526,9632,9637,9641,9644,9650,9670,9673,9678,9682,9685,9762,9777,9785,9790,9794,9819,9825,9830,9834,9837,9840,9860,9865,9869,9900,9905,9909,9925,9930,9934],[10,9505,9506,9507,9510,9511,9514,9515,17,9518,9521],{},"Pour superposer des étages, ouvrez ",[19,9508,9509],{},"Aligner les étages"," pour l’étage à déplacer, affichez un autre étage en superposition et définissez au moins deux ",[19,9512,9513],{},"paires de points"," (par exemple l’angle en bas à droite et un second angle), ou saisissez le décalage et la rotation à la main, puis choisissez ",[19,9516,9517],{},"Enregistrer l’alignement",[19,9519,9520],{},"Placer l’origine ici"," ne sert pas à cela : l’origine du bâtiment est un seul point pour tout le projet, et la modifier déplace tous les étages du même vecteur. Leur position relative ne change donc pas.",[30,9523,9525],{"id":9524},"quel-outil-pour-quel-objectif","Quel outil pour quel objectif ?",[35,9527,9528,9539],{},[38,9529,9530],{},[41,9531,9532,9534,9537],{},[44,9533,4915],{},[44,9535,9536],{},"Outil",[44,9538,7692],{},[54,9540,9541,9560,9583,9595,9608,9620],{},[41,9542,9543,9546,9551],{},[59,9544,9545],{},"Faire coïncider un étage avec un autre (angles, murs)",[59,9547,9548,9550],{},[19,9549,9509],{}," avec paires de points",[59,9552,9553,9554,9556,9557,9559],{},"Barre d’outils du mode ",[19,9555,4073],{},", menu ",[19,9558,5013],{},", pastille d’état de l’étage dans la vue du bâtiment",[41,9561,9562,9565,9580],{},[59,9563,9564],{},"Corriger l’alignement de quelques centimètres",[59,9566,9567,9570,9571,4004,9574,4004,9577],{},[19,9568,9569],{},"Réglage fin"," : flèches, ",[19,9572,9573],{},"Décalage X (m)",[19,9575,9576],{},"Décalage Y (m)",[19,9578,9579],{},"Rotation (°)",[59,9581,9582],{},"Fenêtre d’alignement",[41,9584,9585,9588,9593],{},[59,9586,9587],{},"Utiliser un escalier ou une gaine comme point commun",[59,9589,9590],{},[19,9591,9592],{},"Reprendre un escalier ou une gaine",[59,9594,9582],{},[41,9596,9597,9600,9604],{},[59,9598,9599],{},"Fixer le point zéro de tout le bâtiment",[59,9601,9602],{},[19,9603,9520],{},[59,9605,9553,9606],{},[19,9607,4073],{},[41,9609,9610,9613,9618],{},[59,9611,9612],{},"Revenir aux valeurs de départ",[59,9614,9615],{},[19,9616,9617],{},"Rétablir les hypothèses",[59,9619,9582],{},[41,9621,9622,9625,9630],{},[59,9623,9624],{},"Saisir niveau du sol fini, hauteur libre et dalle",[59,9626,9627],{},[19,9628,9629],{},"Hauteurs physiques",[59,9631,9582],{},[10,9633,9634],{},[26,9635],{"id":9636},"origin",[30,9638,9640],{"id":9639},"pourquoi-tous-les-étages-bougent-ils-quand-je-place-lorigine","Pourquoi tous les étages bougent-ils quand je place l’origine ?",[10,9642,9643],{},"L’origine du bâtiment est le point zéro du système de coordonnées commun du projet. Elle n’existe qu’une fois, pas par étage. Elle est enregistrée dans les coordonnées de l’étage de référence ; si vous cliquez sur un autre étage, le point est d’abord reporté sur l’étage de référence.",[10,9645,9646,9647,9649],{},"Au moment de ",[19,9648,9520],{},", PlanElec décale la position enregistrée de tous les étages du même vecteur. Le message de confirmation le dit : « Origine du bâtiment définie. Tous les étages conservent leur position relative. » L’origine change donc le point de départ des coordonnées, pas l’écart entre deux étages. Si deux étages sont mal superposés avant, ils le restent après.",[10,9651,9652,9653,3981,9655,9657,9658,9661,9662,9665,9666,9669],{},"Pour placer l’origine : passez en mode ",[19,9654,4073],{},[19,9656,9520],{}," dans la barre d’outils et cliquez sur le point voulu. Les nœuds de mur s’aimantent, l’origine tombe donc sur un angle réel. Tant que vous n’avez jamais défini l’origine et que l’étage de référence est actif, une pastille ",[19,9659,9660],{},"Placer l’origine ici (en bas à gauche)"," propose l’angle inférieur gauche du contour extérieur. ",[19,9663,9664],{},"Afficher l’origine et les repères"," montre le repère, ",[19,9667,9668],{},"Aller à l’origine"," centre la vue dessus.",[10,9671,9672],{},"Si vous voulez que l’angle en bas à droite serve de point zéro, placez l’origine à cet endroit sur l’étage de référence. Cela n’aligne pas les autres étages ; il faut pour cela l’alignement ci-dessous.",[10,9674,9675],{},[26,9676],{"id":9677},"pairs",[30,9679,9681],{"id":9680},"comment-aligner-un-étage-avec-des-paires-de-points","Comment aligner un étage avec des paires de points ?",[10,9683,9684],{},"Les paires de points sont la méthode la plus directe quand les étages ont les mêmes dimensions extérieures.",[261,9686,9687,9690,9712,9732,9741,9744,9757],{},[152,9688,9689],{},"Activez l’étage à déplacer. L’étage de référence ne se déplace pas (voir plus bas).",[152,9691,9692,9693,9695,9696,9698,9699,9702,9703,9705,9706,9708,9709,4014],{},"Ouvrez l’alignement : ",[19,9694,9509],{}," dans la barre d’outils du mode ",[19,9697,4073],{},", ou ",[19,9700,9701],{},"Aligner la position …"," dans le menu ",[19,9704,5013],{}," du sélecteur d’étages, ou un clic sur la pastille d’état de l’étage dans la vue du bâtiment. La barre d’outils des escaliers propose aussi ",[19,9707,9509],{},". La fenêtre s’intitule ",[19,9710,9711],{},"Aligner les étages et définir les hauteurs",[152,9713,3977,9714,9717,9718,9721,9722,7427,9725,293,9728,9731],{},[19,9715,9716],{},"Superposition de référence",", choisissez l’étage à montrer dans ",[19,9719,9720],{},"Afficher un autre étage",". Réglez ",[19,9723,9724],{},"Opacité de la superposition",[19,9726,9727],{},"Clignoter",[19,9729,9730],{},"Afficher la référence"," (bouton maintenu ou touche Alt) aident à comparer.",[152,9733,3977,9734,3981,9737,9740],{},[19,9735,9736],{},"Paires de points",[19,9738,9739],{},"Définir une paire de points",". Le bouton n’est actif qu’avec une superposition. La fenêtre se ferme : cliquez d’abord sur le point dans le plan actuel (« Sélectionnez le point dans le plan actuel »), puis sur le même point dans la superposition.",[152,9742,9743],{},"Répétez avec un second point éloigné du premier, par exemple l’autre angle du mur du bas. Dès deux paires, le décalage et la rotation sont calculés automatiquement ; une seule paire ne détermine pas la rotation. Deux points qui se superposent ne déterminent aucune position.",[152,9745,9746,9747,4004,9750,120,9753,9756],{},"Contrôlez ",[19,9748,9749],{},"Écart moyen",[19,9751,9752],{},"Écart maximal",[19,9754,9755],{},"Écart d’échelle observé",". L’échelle reste fixée à 50 unités de plan par mètre : seuls le décalage et la rotation changent. Des écarts notables montrent que les plans ne coïncident pas exactement.",[152,9758,5031,9759,9761],{},[19,9760,9517],{},". L’enregistrement forme une seule étape d’annulation.",[10,9763,9764,9765,9768,9769,9772,9773,9776],{},"Avec la fonction ",[19,9766,9767],{},"Modifier les repères dans le plan",", vous déplacez les repères, puis ",[19,9770,9771],{},"Revenir à l’alignement"," rouvre la fenêtre. Une paire ne se supprime individuellement qu’à partir de trois paires ; ",[19,9774,9775],{},"Abandonner les paires de points"," les efface toutes.",[10,9778,9779,9780,3981,9782,4014],{},"Un escalier ou une gaine qui relie l’étage actif à l’étage de référence peut servir de paire : sous ",[19,9781,9592],{},[19,9783,9784],{},"Reprendre",[10,9786,9787],{},[26,9788],{"id":9789},"numeric",[30,9791,9793],{"id":9792},"comment-saisir-le-décalage-et-la-rotation-à-la-main","Comment saisir le décalage et la rotation à la main ?",[10,9795,3977,9796,9798,9799,4004,9801,120,9803,9805,9806,4004,9809,4004,9812,120,9815,9818],{},[19,9797,9569],{},", saisissez ",[19,9800,9573],{},[19,9802,9576],{},[19,9804,9579],{},". Le décalage est exprimé en mètres dans le système de coordonnées du bâtiment ; gardez une superposition affichée pour vérifier le résultat. Les boutons ",[19,9807,9808],{},"Vers le haut",[19,9810,9811],{},"Vers le bas",[19,9813,9814],{},"Vers la gauche",[19,9816,9817],{},"Vers la droite"," déplacent l’étage de 1 cm, de 10 cm avec Maj.",[10,9820,9821,9822,9824],{},"Tant que des paires de points déterminent la position, ces champs sont verrouillés (« Le décalage et la rotation découlent des paires de points et sont donc verrouillés. »). Choisissez ",[19,9823,9775],{}," pour reprendre la main.",[10,9826,9827],{},[26,9828],{"id":9829},"reference",[30,9831,9833],{"id":9832},"quel-est-létage-de-référence","Quel est l’étage de référence ?",[10,9835,9836],{},"La fenêtre l’indique en haut : « Origine du bâtiment : » suivi du nom de l’étage. L’étage de référence définit l’origine du bâtiment. Par défaut, c’est l’étage de niveau 0, à défaut le plus bas. Son décalage découle de l’origine choisie et ne se modifie pas dans la fenêtre : pas de paires de points, champs et flèches inactifs.",[10,9838,9839],{},"L’interface ne propose pas de commande pour choisir soi-même l’étage de référence. Si vous supprimez l’étage de référence, l’étage voisin prend ce rôle, l’origine revient à sa valeur par défaut et les étages restants gardent leur position relative.",[10,9841,9842,9843,9846,9847,4004,9850,9853,9854,17,9857,9859],{},"Un nouvel étage est supposé se trouver à la même place que la référence. Dans ",[19,9844,9845],{},"Créer un étage",", la question « Comment l’étage se situe-t-il par rapport à la référence ? » propose ",[19,9848,9849],{},"Comme la référence",[19,9851,9852],{},"Ajuster maintenant"," (ouvre directement l’alignement) et ",[19,9855,9856],{},"Plus tard",[19,9858,9852],{}," manque quand le nouvel étage deviendrait lui-même la référence.",[10,9861,9862],{},[26,9863],{"id":9864},"reset",[30,9866,9868],{"id":9867},"comment-annuler-ou-rétablir-un-alignement","Comment annuler ou rétablir un alignement ?",[149,9870,9871,9876,9888],{},[152,9872,9873,9875],{},[19,9874,9617],{}," remet décalage et rotation à zéro, l’état à « Supposé », les hauteurs aux valeurs par défaut du niveau et retire la superposition. Sur l’étage de référence, cela rétablit le décalage issu de l’origine, sans déplacer l’origine.",[152,9877,9878,9879,132,9882,293,9885,4014],{},"La fermeture de la fenêtre avec des modifications non enregistrées affiche ",[19,9880,9881],{},"Abandonner l’alignement ?",[19,9883,9884],{},"Continuer à modifier",[19,9886,9887],{},"Abandonner",[152,9889,9890,9891,4004,9894,293,9897,4014],{},"L’état de chaque étage apparaît dans sa pastille : ",[19,9892,9893],{},"Supposé",[19,9895,9896],{},"Confirmé",[19,9898,9899],{},"À vérifier",[10,9901,9902],{},[26,9903],{"id":9904},"heights",[30,9906,9908],{"id":9907},"où-saisir-les-hauteurs-des-étages","Où saisir les hauteurs des étages ?",[10,9910,9911,9912,9914,9915,4004,9918,120,9921,9924],{},"Dans la même fenêtre, sous ",[19,9913,9629],{}," : ",[19,9916,9917],{},"Niveau du sol fini (m)",[19,9919,9920],{},"Hauteur libre (m)",[19,9922,9923],{},"Épaisseur de dalle supérieure (m)",". Les valeurs par défaut restent des hypothèses ; seules les hauteurs réellement modifiées sont confirmées à l’enregistrement. Si l’ordre des étages se chevauche en hauteur, PlanElec refuse l’enregistrement et indique le niveau minimal requis.",[10,9926,9927,9928,4014],{},"Position et hauteurs sont enregistrées ensemble par ",[19,9929,9517],{},[30,9931,9933],{"id":9932},"voir-aussi","Voir aussi",[149,9935,9936,9941],{},[152,9937,9938,9940],{},[26,9939,119],{"href":118}," pour mettre chaque plan à l’échelle avant de superposer les étages.",[152,9942,9943,4014],{},[26,9944,4438],{"href":4437},{"title":822,"searchDepth":823,"depth":823,"links":9946},[9947,9948,9949,9950,9951,9952,9953,9954],{"id":9524,"depth":823,"text":9525},{"id":9639,"depth":823,"text":9640},{"id":9680,"depth":823,"text":9681},{"id":9792,"depth":823,"text":9793},{"id":9832,"depth":823,"text":9833},{"id":9867,"depth":823,"text":9868},{"id":9907,"depth":823,"text":9908},{"id":9932,"depth":823,"text":9933},"Alignez un étage sur un autre avec des paires de points ou un décalage numérique, et comprenez pourquoi « Placer l’origine ici » déplace tous les étages ensemble.","floor-alignment-building-origin","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Ffloor-alignment-building-origin-fr.webp",{},11,"\u002Fhelp\u002Ffloor-alignment-building-origin.fr","2026-10-09",{"title":9501,"description":9955},"Aligner les étages et origine du bâtiment","aligner-les-etages-et-origine-du-batiment","help\u002Ffloor-alignment-building-origin.fr",[9967,9968,9969,9736,9970,9971],"Étages","Alignement","Origine du bâtiment","Superposition","Hauteurs","6z_419kWRx5RDj7jRdgdhSAsipZYpALgR6OEdMRRN60",{"id":9974,"title":4350,"body":9975,"category":5452,"description":10864,"extension":846,"guideId":10865,"image":10866,"locale":849,"meta":10867,"navigation":851,"order":10868,"path":10869,"publishedAt":6105,"readTime":855,"seo":10870,"seoTitle":857,"slug":10871,"stem":10872,"tags":10873,"updatedAt":854,"__hash__":10875},"help\u002Fhelp\u002Ffloorplan-recognition.fr.md",{"type":7,"value":9976,"toc":10846},[9977,9994,9998,10002,10078,10084,10089,10093,10098,10102,10138,10142,10180,10185,10189,10196,10243,10255,10268,10273,10277,10290,10388,10395,10400,10404,10411,10416,10420,10426,10468,10474,10499,10504,10508,10513,10578,10595,10600,10605,10609,10637,10640,10645,10650,10654,10657,10726,10730,10734,10811,10815,10819,10824,10828],[10,9978,9979,9980,9983,9984,9987,9988,9990,9991,9993],{},"La reconnaissance de plan lit une page de plan – PDF, PNG, JPEG ou WebP, y compris un export PDF de Trikker – et en tire une ",[19,9981,9982],{},"proposition"," : murs, pièces avec leur surface calculée, portes et fenêtres, ainsi que les symboles électriques connus de PlanElec. Il vous faut au minimum le rôle de projet ",[19,9985,9986],{},"Éditeur",". Vous vérifiez la proposition dans le panneau ",[19,9989,7572],{},", la corrigez si nécessaire et confirmez l’échelle. Ensuite seulement, ",[19,9992,9784],{}," la transfère dans un étage vide, en une seule étape annulable. Aucun circuit, schéma unifilaire ou câble n’est créé ; vous les planifiez ensuite comme d’habitude.",[10,9995,9996],{},[26,9997],{"id":143},[30,9999,10001],{"id":10000},"de-quoi-avez-vous-besoin","De quoi avez-vous besoin ?",[35,10003,10004,10014],{},[38,10005,10006],{},[41,10007,10008,10011],{},[44,10009,10010],{},"Condition",[44,10012,10013],{},"Ce qui s’applique",[54,10015,10016,10036,10044,10052,10060,10070],{},[41,10017,10018,10021],{},[59,10019,10020],{},"Rôle dans le projet",[59,10022,10023,4004,10026,293,10029,10031,10032,10035],{},[19,10024,10025],{},"Propriétaire",[19,10027,10028],{},"Administrateur",[19,10030,9986],{},". Avec le rôle ",[19,10033,10034],{},"Lecteur",", aucune reconnaissance ne peut être lancée.",[41,10037,10038,10041],{},[59,10039,10040],{},"Format de fichier",[59,10042,10043],{},"PDF, PNG, JPEG ou WebP jusqu’à 50 Mo. Les fichiers DXF et DWG ne sont pas reconnus.",[41,10045,10046,10049],{},[59,10047,10048],{},"Page de plan",[59,10050,10051],{},"Une page qui montre un plan d’étage. Pour un PDF de plusieurs pages, vous choisissez vous-même la page.",[41,10053,10054,10057],{},[59,10055,10056],{},"Niveau cible",[59,10058,10059],{},"Un étage vide, sans murs. La reprise dans un étage déjà dessiné est bloquée.",[41,10061,10062,10064],{},[59,10063,7413],{},[59,10065,10066,10067,10069],{},"Doit être confirmée avant la reprise. Sans échelle confirmée, ",[19,10068,9784],{}," reste bloqué.",[41,10071,10072,10075],{},[59,10073,10074],{},"Quota",[59,10076,10077],{},"30 passages de reconnaissance par utilisateur et par jour ; chaque passage consomme aussi votre quota IA.",[10,10079,10080,10081,10083],{},"Le fichier est rangé dans les ",[19,10082,711],{},". Vous ne chargez donc le plan qu’une fois : il sert de source à la reconnaissance et reste ensuite disponible comme pièce du projet.",[10,10085,10086],{},[26,10087],{"id":10088},"start",[30,10090,10092],{"id":10091},"où-lancer-la-reconnaissance","Où lancer la reconnaissance ?",[10,10094,10095,10096,4014],{},"Deux points d’entrée mènent au même résultat dans le panneau ",[19,10097,7572],{},[390,10099,10101],{"id":10100},"sur-un-étage-vide","Sur un étage vide",[261,10103,10104,10112,10117,10123,10132],{},[152,10105,7620,10106,10108,10109,10111],{},[19,10107,4073],{},", ouvrez un étage sans murs ni calque. La carte ",[19,10110,4324],{}," s’affiche.",[152,10113,5031,10114,10116],{},[19,10115,4346],{},", puis votre fichier.",[152,10118,10119,10120,10122],{},"PlanElec range le plan dans les pièces du projet et affiche la progression en trois étapes. ",[19,10121,4893],{}," interrompt le passage.",[152,10124,10125,10126,10129,10130,4014],{},"Pour un plan d’une seule page, la reconnaissance démarre aussitôt. Si le PDF compte plusieurs pages, l’",[19,10127,10128],{},"Aperçu des pièces"," s’ouvre : allez à la page du plan et lancez-y ",[19,10131,7546],{},[152,10133,10134,10135,4555],{},"Critère de réussite : le message « Plan reconnu. Vérifiez l’ébauche et mesurez une distance connue. » apparaît et la fenêtre ",[19,10136,10137],{},"Corriger la proposition",[390,10139,10141],{"id":10140},"depuis-les-pièces-du-projet","Depuis les pièces du projet",[261,10143,10144,10157,10160,10171],{},[152,10145,4455,10146,10148,10149,10152,10153,10156],{},[19,10147,711],{},". À côté d’un PDF figure l’action ",[19,10150,10151],{},"Reconnaître le plan par IA",", à côté d’une image ",[19,10154,10155],{},"Reconnaître la photo par IA",". Les deux lancent la reconnaissance de plan.",[152,10158,10159],{},"Pour un PDF de plusieurs pages, c’est l’aperçu qui s’ouvre. Choisissez-y la page.",[152,10161,5811,10162,10164,10165,10168,10169,4014],{},[19,10163,10128],{},", sélectionnez la méthode sous ",[19,10166,10167],{},"Méthode de reconnaissance"," et lancez ",[19,10170,7546],{},[152,10172,10173,10174,10176,10177,10179],{},"Après le passage, PlanElec bascule vers le mode ",[19,10175,4073],{}," et ouvre le panneau ",[19,10178,7572],{},". La proposition s’affiche en aperçu sur l’étage.",[10,10181,10182],{},[26,10183],{"id":10184},"method",[30,10186,10188],{"id":10187},"que-fait-la-méthode-automatique","Que fait la méthode « Automatique » ?",[10,10190,10191,10192,10195],{},"Par défaut, la méthode est ",[19,10193,10194],{},"Automatique (vecteurs PDF + IA)",". Le serveur décide, page par page, d’où viennent les murs :",[35,10197,10198,10210],{},[38,10199,10200],{},[41,10201,10202,10204,10207],{},[44,10203,4073],{},[44,10205,10206],{},"Origine des murs",[44,10208,10209],{},"Ce que l’IA ajoute",[54,10211,10212,10223,10234],{},[41,10213,10214,10217,10220],{},[59,10215,10216],{},"PDF vectoriel dont les traits de murs forment des pièces fermées",[59,10218,10219],{},"directement des traits du PDF",[59,10221,10222],{},"noms et catégories de pièces, fenêtres, symboles d’appareils et cotes lues",[41,10224,10225,10228,10231],{},[59,10226,10227],{},"PDF scanné ou PDF sans tracés de murs fermés",[59,10229,10230],{},"reconnaissance d’image par IA",[59,10232,10233],{},"pour un PDF, aussi les noms de pièces issus de la couche texte et les portes issues des arcs d’ouverture dessinés",[41,10235,10236,10239,10241],{},[59,10237,10238],{},"PNG, JPEG, WebP",[59,10240,10230],{},[59,10242,586],{},[10,10244,10245,10246,10248,10249,293,10252,4014],{},"Si l’IA échoue sur un PDF vectoriel, les murs du PDF restent disponibles comme proposition. En tête du panneau ",[19,10247,7572],{},", vous voyez la voie suivie, par exemple ",[19,10250,10251],{},"Murs du PDF + IA",[19,10253,10254],{},"Proposition de murs du PDF",[10,10256,10257,10260,10261,10264,10265,10267],{},[19,10258,10259],{},"Reconnaissance par LLM"," impose la reconnaissance d’image seule, sans vecteurs PDF. C’est une alternative lorsque le choix automatique donne un résultat faible. ",[19,10262,10263],{},"Relancer la reconnaissance",", dans le panneau ",[19,10266,7572],{},", relance le même plan avec la méthode choisie. Chaque nouveau passage compte dans le quota journalier.",[10,10269,10270],{},[26,10271],{"id":10272},"review",[30,10274,10276],{"id":10275},"que-contient-la-proposition-et-comment-la-vérifier","Que contient la proposition et comment la vérifier ?",[10,10278,4513,10279,10281,10282,4004,10285,293,10288,4014],{},[19,10280,7572],{}," découpe la proposition en sections. En haut figurent la page et le statut : ",[19,10283,10284],{},"Proposition",[19,10286,10287],{},"Saisie requise",[19,10289,455],{},[35,10291,10292,10305],{},[38,10293,10294],{},[41,10295,10296,10299,10302],{},[44,10297,10298],{},"Section",[44,10300,10301],{},"Ce que vous voyez",[44,10303,10304],{},"Ce que vous décidez",[54,10306,10307,10320,10333,10346,10359,10372],{},[41,10308,10309,10314,10317],{},[59,10310,10311],{},[19,10312,10313],{},"Pièces",[59,10315,10316],{},"chaque pièce fermée avec sa surface calculée, la surface imprimée sur le plan et l’écart",[59,10318,10319],{},"reprendre le nom ou le décocher. Décocher supprime uniquement le nom ; les murs restent.",[41,10321,10322,10327,10330],{},[59,10323,10324],{},[19,10325,10326],{},"Ouvertures",[59,10328,10329],{},"porte ou fenêtre avec sa largeur",[59,10331,10332],{},"cocher ou décocher chaque ouverture",[41,10334,10335,10339,10342],{},[59,10336,10337],{},[19,10338,7413],{},[59,10340,10341],{},"origine, ancres en mètres, écart",[59,10343,10344],{},[19,10345,7586],{},[41,10347,10348,10353,10356],{},[59,10349,10350],{},[19,10351,10352],{},"Noms",[59,10354,10355],{},"les noms de pièces qui seront repris",[59,10357,10358],{},"contrôle avant la reprise",[41,10360,10361,10366,10369],{},[59,10362,10363],{},[19,10364,10365],{},"Appareils",[59,10367,10368],{},"symboles reconnus, comme prise, interrupteur, point lumineux",[59,10370,10371],{},"cocher ou décocher chaque appareil",[41,10373,10374,10379,10385],{},[59,10375,10376],{},[19,10377,10378],{},"Questions",[59,10380,10381,10382],{},"points ouverts ; ceux qui bloquent portent la mention ",[19,10383,10384],{},"bloquant",[59,10386,10387],{},"les régler avant la reprise",[10,10389,10390,10391,10394],{},"Symboles reconnus : prise, prise double, prise étanche, prise avec interrupteur, interrupteur, bouton-poussoir, bouton de sonnette, détecteur de mouvement, point lumineux, spot, applique murale, tube fluorescent, transformateur, prises Ethernet et coaxiale, tableau de répartition, boîte de dérivation, plaque de cuisson, four, lave-vaisselle, lave-linge, sèche-linge, réfrigérateur, hotte aspirante, chauffe-eau, moteur de volet roulant et détecteur de fumée. Un symbole hors de cette liste apparaît comme ",[19,10392,10393],{},"Symbole inconnu"," et n’est pas repris.",[10,10396,10397],{},[26,10398],{"id":10399},"printed-areas",[390,10401,10403],{"id":10402},"les-surfaces-imprimées-comme-contre-épreuve","Les surfaces imprimées comme contre-épreuve",[10,10405,10406,10407,10410],{},"Beaucoup de plans d’architecte indiquent la surface de chaque pièce. Ce chiffre vient de l’annotation, pas des murs reconnus : c’est donc un contrôle indépendant. S’il concorde, ",[19,10408,10409],{},"✓ plan"," s’affiche à côté de la pièce. Si une pièce s’écarte de 10 % ou plus, PlanElec le signale au-dessus de la liste des pièces : un mur est sans doute mal placé. Si l’ensemble des surfaces imprimées ne correspond pas à l’échelle, une question apparaît et vous mesurez une longueur connue.",[10,10412,10413],{},[26,10414],{"id":10415},"scale",[30,10417,10419],{"id":10418},"doù-vient-léchelle","D’où vient l’échelle ?",[10,10421,10422,10423,10425],{},"Une proposition sans échelle confirmée n’est pas reprise. La section ",[19,10424,7413],{}," indique son origine :",[35,10427,10428,10436],{},[38,10429,10430],{},[41,10431,10432,10434],{},[44,10433,4800],{},[44,10435,5749],{},[54,10437,10438,10448,10458],{},[41,10439,10440,10445],{},[59,10441,10442],{},[19,10443,10444],{},"À partir des cotes",[59,10446,10447],{},"L’IA lit les cotes de la page. Plusieurs cotes indépendantes sont évaluées ensemble.",[41,10449,10450,10455],{},[59,10451,10452],{},[19,10453,10454],{},"À partir de l’échelle du PDF",[59,10456,10457],{},"L’échelle enregistrée dans le PDF. Elle est confrontée aux cotes lues ; si elles la contredisent, ce sont les cotes qui priment.",[41,10459,10460,10465],{},[59,10461,10462],{},[19,10463,10464],{},"Deux points, mesurés par vos soins",[59,10466,10467],{},"Vous avez marqué une distance connue dans la fenêtre de correction et saisi sa longueur.",[10,10469,10470,10471,10473],{},"Votre propre mesure a priorité. Si elle contredit plusieurs cotes concordantes, PlanElec retient les cotes et le signale sous ",[19,10472,10378],{},". Vérifiez alors que vous avez placé les bons points.",[261,10475,10476,10481,10484,10493],{},[152,10477,10478,10479,4014],{},"Lisez l’origine et l’écart dans la section ",[19,10480,7413],{},[152,10482,10483],{},"Comparez une distance dont vous connaissez la longueur avec la proposition, par exemple un mur extérieur coté.",[152,10485,10486,10487,10489,10490,4014],{},"Si elle concorde, choisissez ",[19,10488,7586],{},". L’affichage passe à ",[19,10491,10492],{},"Échelle confirmée",[152,10494,10495,10496,10498],{},"Sinon, ouvrez ",[19,10497,10137],{}," et mesurez vous-même la distance.",[10,10500,10501],{},[26,10502],{"id":10503},"correct",[30,10505,10507],{"id":10506},"comment-corriger-la-proposition","Comment corriger la proposition ?",[10,10509,10510,10512],{},[19,10511,10137],{}," affiche la page d’origine avec les murs reconnus par-dessus. Si seule l’échelle manque, la fenêtre s’ouvre d’elle-même. Les modifications ne sont écrites dans l’étage qu’au moment de la reprise.",[35,10514,10515,10524],{},[38,10516,10517],{},[41,10518,10519,10521],{},[44,10520,9536],{},[44,10522,10523],{},"À quoi il sert",[54,10525,10526,10539,10549,10559,10569],{},[41,10527,10528,10533],{},[59,10529,10530],{},[19,10531,10532],{},"Mesurer une distance",[59,10534,10535,10536],{},"marquer deux points d’une distance connue et saisir la ",[19,10537,10538],{},"Longueur en mètres",[41,10540,10541,10546],{},[59,10542,10543],{},[19,10544,10545],{},"Déplacer un angle",[59,10547,10548],{},"faire glisser un angle au bon endroit ; après sélection, aussi avec les flèches du clavier",[41,10550,10551,10556],{},[59,10552,10553],{},[19,10554,10555],{},"Ajouter un mur",[59,10557,10558],{},"cliquer le début et la fin d’un mur manquant ; les angles existants s’accrochent",[41,10560,10561,10566],{},[59,10562,10563],{},[19,10564,10565],{},"Supprimer un mur",[59,10567,10568],{},"cliquer sur un mur erroné ; ses ouvertures disparaissent avec lui",[41,10570,10571,10575],{},[59,10572,10573],{},[19,10574,9472],{},[59,10576,10577],{},"revenir sur la dernière correction dans la fenêtre",[261,10579,10580,10586,10589],{},[152,10581,10582,10583,10585],{},"Mesurez une longueur connue avec ",[19,10584,10532],{},", de préférence une grande.",[152,10587,10588],{},"Contrôlez chaque pièce : elle doit être fermée par des murs sur tout son pourtour. Ajoutez les murs manquants et déplacez les angles mal placés.",[152,10590,5031,10591,10594],{},[19,10592,10593],{},"Enregistrer la proposition",". L’échelle est alors considérée comme confirmée. Si le niveau cible est vide et qu’aucune question ne bloque, PlanElec reprend aussitôt la proposition. Sinon, un message en donne la raison et vous la reprendrez plus tard.",[10,10596,10597,10598,4014],{},"Une photo déformée ou un plan au cadrage incertain ne se redresse pas dans cette fenêtre. Placez alors le plan comme calque et ajustez-le dans l’atelier de calque, voir ",[26,10599,119],{"href":118},[10,10601,10602],{},[26,10603],{"id":10604},"apply",[30,10606,10608],{"id":10607},"comment-reprendre-la-proposition-dans-létage","Comment reprendre la proposition dans l’étage ?",[261,10610,10611,10619,10624,10628],{},[152,10612,10613,10614,5815,10616,10618],{},"En bas du panneau ",[19,10615,7572],{},[19,10617,10056],{},". Il doit être vide.",[152,10620,10621,10622,4014],{},"Vérifiez que l’échelle est confirmée et qu’aucune question n’affiche ",[19,10623,10384],{},[152,10625,5031,10626,4014],{},[19,10627,9784],{},[152,10629,10630,10631,10633,10634,4014],{},"Critère de réussite : le message « La proposition a été reprise. » apparaît et le mode ",[19,10632,4073],{}," montre murs, pièces, ouvertures et appareils. Sous les murs, la page d’origine reste en calque sous le nom ",[19,10635,10636],{},"Page de plan reconnue",[10,10638,10639],{},"Toute la reprise forme une seule étape annulable : ⌘Z ou Ctrl+Z la retire entièrement. Si un élément n’a pas pu être placé – une porte sans mur correspondant ou un appareil sans mur à proximité, par exemple –, PlanElec indique le nombre d’éléments non repris. Vous les placez à la main. Les pièces reçoivent leur nom et, lorsqu’elle a été reconnue, une catégorie. Si le plan n’indique pas la hauteur des portes et fenêtres, PlanElec applique des valeurs standard ; vérifiez-les si nécessaire.",[10,10641,10642,10643,4014],{},"Si vous avez reconnu plusieurs étages séparément, superposez-les ensuite : ",[26,10644,9963],{"href":4397},[10,10646,10647],{},[26,10648],{"id":10649},"no-result",[30,10651,10653],{"id":10652},"que-faire-si-la-reconnaissance-ne-donne-rien-dexploitable","Que faire si la reconnaissance ne donne rien d’exploitable ?",[10,10655,10656],{},"Si la reconnaissance lancée depuis la carte de démarrage ne trouve pas de plan exploitable – moins de trois murs –, PlanElec écarte la proposition. Le plan est alors posé comme calque sur l’étage, l’atelier de calque s’ouvre et vous redessinez les murs extérieurs. Autres situations :",[35,10658,10659,10669],{},[38,10660,10661],{},[41,10662,10663,10665,10667],{},[44,10664,9313],{},[44,10666,405],{},[44,10668,8899],{},[54,10670,10671,10682,10693,10704,10716],{},[41,10672,10673,10676,10679],{},[59,10674,10675],{},"Quota journalier épuisé",[59,10677,10678],{},"30 passages déjà utilisés aujourd’hui ; les passages échoués comptent aussi",[59,10680,10681],{},"Réessayer le lendemain (UTC) ou redessiner le plan",[41,10683,10684,10687,10690],{},[59,10685,10686],{},"Délai dépassé",[59,10688,10689],{},"Le passage a pris trop de temps",[59,10691,10692],{},"Réessayer ou choisir une autre méthode",[41,10694,10695,10698,10701],{},[59,10696,10697],{},"Fichier non reconnaissable",[59,10699,10700],{},"Format non pris en charge ou plus de 50 Mo",[59,10702,10703],{},"Utiliser PDF, PNG, JPEG ou WebP",[41,10705,10706,10710,10713],{},[59,10707,10708],{},[19,10709,10287],{},[59,10711,10712],{},"Il manque le plus souvent l’échelle",[59,10714,10715],{},"Mesurer une distance connue dans la fenêtre de correction",[41,10717,10718,10720,10723],{},[59,10719,9355],{},[59,10721,10722],{},"Votre quota IA restant ne suffit pas pour ce passage",[59,10724,10725],{},"Redessiner le plan à partir du calque",[10,10727,10728],{},[26,10729],{"id":180},[30,10731,10733],{"id":10732},"quest-ce-que-lia-ne-reconnaît-pas","Qu’est-ce que l’IA ne reconnaît pas ?",[35,10735,10736,10745],{},[38,10737,10738],{},[41,10739,10740,10742],{},[44,10741,193],{},[44,10743,10744],{},"Ce que cela signifie",[54,10746,10747,10755,10769,10779,10787,10795,10803],{},[41,10748,10749,10752],{},[59,10750,10751],{},"Pas de circuits, de schéma ni de câbles",[59,10753,10754],{},"Sont reconnus l’emplacement et le type des symboles. Affectation, protections et schéma unifilaire se planifient ensuite.",[41,10756,10757,10760],{},[59,10758,10759],{},"Pas de plan issu des fichiers de projet Trikker",[59,10761,10762,10763,10765,10766,10768],{},"Un export PDF de Trikker est reconnu comme tout PDF. Un fichier ",[14,10764,16],{}," s’importe comme projet (schéma, circuits, appareils), voir ",[26,10767,69],{"href":4115}," ; son plan n’est pas repris.",[41,10770,10771,10774],{},[59,10772,10773],{},"Pas de reprise sans échelle",[59,10775,10776,10777,10069],{},"Sans échelle confirmée, ",[19,10778,9784],{},[41,10780,10781,10784],{},[59,10782,10783],{},"Étages vides uniquement",[59,10785,10786],{},"La reconnaissance ne complète pas un plan existant.",[41,10788,10789,10792],{},[59,10790,10791],{},"Pas de reconnaissance DXF\u002FDWG",[59,10793,10794],{},"Un DXF s’importe comme calque à l’échelle via l’import habituel.",[41,10796,10797,10800],{},[59,10798,10799],{},"Pas de coupes ni d’élévations",[59,10801,10802],{},"La reconnaissance attend un plan d’étage ; les autres types de feuilles ne donnent pas de proposition exploitable.",[41,10804,10805,10808],{},[59,10806,10807],{},"Une proposition n’est pas un relevé",[59,10809,10810],{},"Vérifiez cotes, tracé des murs et symboles avant de poursuivre la planification.",[10,10812,10813],{},[26,10814],{"id":682},[30,10816,10818],{"id":10817},"que-devient-votre-plan","Que devient votre plan ?",[10,10820,10821,10822,4014],{},"Le fichier est conservé dans les pièces de votre projet. Seule la page choisie est transmise au fournisseur d’IA externe : sous forme d’image et, pour un PDF, avec le texte de cette page. La requête passe par une route européenne ; le fournisseur ne la conserve pas et ne s’en sert pas pour l’entraînement. PlanElec journalise chaque passage avec la page transmise et le résultat, afin qu’une proposition reste traçable. Le message « La page sera transmise à un fournisseur d’IA externe pour analyse. » figure directement sur l’action ",[19,10823,7546],{},[30,10825,10827],{"id":10826},"et-ensuite","Et ensuite ?",[149,10829,10830,10835,10841],{},[152,10831,10832,10833],{},"Compléter les symboles et les relier à la topologie : ",[26,10834,4438],{"href":4437},[152,10836,10837,10838],{},"Planifier circuits et tableaux : ",[26,10839,10840],{"href":4494},"Planifier l’installation et les tableaux secondaires",[152,10842,10843,10844],{},"Redessiner un plan sans IA ou étalonner l’échelle à la main : ",[26,10845,119],{"href":118},{"title":822,"searchDepth":823,"depth":823,"links":10847},[10848,10849,10853,10854,10857,10858,10859,10860,10861,10862,10863],{"id":10000,"depth":823,"text":10001},{"id":10091,"depth":823,"text":10092,"children":10850},[10851,10852],{"id":10100,"depth":831,"text":10101},{"id":10140,"depth":831,"text":10141},{"id":10187,"depth":823,"text":10188},{"id":10275,"depth":823,"text":10276,"children":10855},[10856],{"id":10402,"depth":831,"text":10403},{"id":10418,"depth":823,"text":10419},{"id":10506,"depth":823,"text":10507},{"id":10607,"depth":823,"text":10608},{"id":10652,"depth":823,"text":10653},{"id":10732,"depth":823,"text":10733},{"id":10817,"depth":823,"text":10818},{"id":10826,"depth":823,"text":10827},"Chargez une page de plan en PDF, PNG, JPEG ou WebP, vérifiez la proposition de l’IA avec murs, pièces, portes, fenêtres et symboles d’appareils, confirmez l’échelle et reprenez le tout dans un étage vide.","floorplan-recognition","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Ffloorplan-recognition-fr.webp",{},12,"\u002Fhelp\u002Ffloorplan-recognition.fr",{"title":4350,"description":10864},"reconnaitre-un-plan-avec-l-ia","help\u002Ffloorplan-recognition.fr",[797,9497,6028,7772,10874,861],"pièces","Gkbe3D1HD76ADgHfFJW45oSDMedJxyLnZ8KmiTjkwCY",{"id":10877,"title":10878,"body":10879,"category":5452,"description":11643,"extension":846,"guideId":11644,"image":11645,"locale":849,"meta":11646,"navigation":851,"order":11647,"path":11648,"publishedAt":6105,"readTime":7174,"seo":11649,"seoTitle":11650,"slug":11651,"stem":11652,"tags":11653,"updatedAt":6105,"__hash__":11657},"help\u002Fhelp\u002Fcabinet-photo-recognition.fr.md","Reconnaître un tableau électrique depuis des photos : vérifier et importer les modules DIN",{"type":7,"value":10880,"toc":11631},[10881,10888,10891,10895,10899,10988,10995,11000,11004,11007,11102,11105,11110,11114,11155,11158,11162,11194,11197,11202,11206,11223,11226,11229,11233,11237,11246,11372,11375,11389,11392,11396,11400,11412,11415,11443,11446,11449,11454,11458,11465,11529,11537,11540,11544,11548,11622],[10,10882,10883,10884,10887],{},"Dans l’éditeur de tableau, PlanElec analyse des photos d’un tableau électrique existant et propose les modules DIN visibles : rangée, emplacement, largeur en modules (TE), type de module et valeurs lisibles comme le courant assigné ou la sensibilité. Il vous faut un projet enregistré, le rôle de projet Propriétaire, Administrateur ou Éditeur et un tableau ",[19,10885,10886],{},"vide",". Vous vérifiez et corrigez chaque proposition avant de l’importer ; ce n’est qu’ensuite que les modules prennent place sur les rails. La détection ne déduit ni le câblage caché, ni les circuits, ni les relations de protection : cette partie électrique, vous la complétez ensuite vous-même.",[10,10889,10890],{},"La reconnaissance par photo sert aux installations existantes et aux extensions, lorsque vous voulez reprendre rapidement le montage en place comme point de départ. Chaque détection compte dans votre limite journalière et consomme votre quota IA.",[10,10892,10893],{},[26,10894],{"id":143},[30,10896,10898],{"id":10897},"de-quoi-avez-vous-besoin-pour-la-reconnaissance-par-photo","De quoi avez-vous besoin pour la reconnaissance par photo ?",[35,10900,10901,10909],{},[38,10902,10903],{},[41,10904,10905,10907],{},[44,10906,10010],{},[44,10908,10013],{},[54,10910,10911,10922,10940,10956,10963,10970,10978],{},[41,10912,10913,10916],{},[59,10914,10915],{},"Projet",[59,10917,10918,10919,4014],{},"Le projet est ouvert et enregistré. Ce n’est qu’alors que l’éditeur de tableau affiche le bouton ",[19,10920,10921],{},"Photos",[41,10923,10924,10927],{},[59,10925,10926],{},"Mode de travail",[59,10928,10929,10932,10933,120,10936,10939],{},[19,10930,10931],{},"Montage"," dans l’éditeur de tableau. En ",[19,10934,10935],{},"Câblage",[19,10937,10938],{},"Tableaux",", le panneau photo n’est pas disponible.",[41,10941,10942,10945],{},[59,10943,10944],{},"Rôle de projet",[59,10946,10947,4004,10949,293,10951,10031,10953,10955],{},[19,10948,10025],{},[19,10950,10028],{},[19,10952,9986],{},[19,10954,10034],{},", l’import de photos, la détection et l’import des modules sont bloqués.",[41,10957,10958,10960],{},[59,10959,4480],{},[59,10961,10962],{},"Un tableau sélectionné et vide : aucun module placé et aucun appareil déjà affecté à ce tableau.",[41,10964,10965,10967],{},[59,10966,10921],{},[59,10968,10969],{},"JPEG, PNG ou WebP, six photos au maximum par tableau. Les autres formats n’apparaissent pas dans la liste des photos.",[41,10971,10972,10975],{},[59,10973,10974],{},"Limite journalière",[59,10976,10977],{},"20 détections par utilisateur et par jour. Le compteur repart à minuit UTC (1 h en Belgique, 2 h à l’heure d’été).",[41,10979,10980,10983],{},[59,10981,10982],{},"Quota IA",[59,10984,10985,10986,4014],{},"Chaque détection consomme votre quota IA personnel. La part disponible s’affiche dans le menu utilisateur sous ",[19,10987,10982],{},[10,10989,10990,10991,10994],{},"Si le tableau n’est pas vide, ",[19,10992,10993],{},"Détecter les modules"," reste bloqué et le panneau indique : « La détection est disponible uniquement pour un tableau vide. » C’est aussi le cas lorsque des protections sont déjà affectées à ce tableau dans l’installation sans y être placées.",[10,10996,10997],{},[26,10998],{"id":10999},"recognised",[30,11001,11003],{"id":11002},"que-détecte-planelec-sur-une-photo-de-tableau-électrique","Que détecte PlanElec sur une photo de tableau électrique ?",[10,11005,11006],{},"La détection décrit uniquement ce qui est visible et lisible sur les photos. Les données illisibles ou incertaines restent vides au lieu d’être remplies avec des valeurs standard.",[35,11008,11009,11018],{},[38,11010,11011],{},[41,11012,11013,11015],{},[44,11014,5746],{},[44,11016,11017],{},"Résultat dans la proposition",[54,11019,11020,11028,11036,11044,11052,11060,11068,11080,11091],{},[41,11021,11022,11025],{},[59,11023,11024],{},"Modules DIN visibles",[59,11026,11027],{},"Un cadre sur la photo et une ligne dans la liste de vérification pour chaque module",[41,11029,11030,11033],{},[59,11031,11032],{},"Rangée et emplacement",[59,11034,11035],{},"Estimés de haut en bas et de gauche à droite ; vides si la position n’est pas claire",[41,11037,11038,11041],{},[59,11039,11040],{},"Largeur",[59,11042,11043],{},"Largeur approximative en TE",[41,11045,11046,11049],{},[59,11047,11048],{},"Type de module",[59,11050,11051],{},"Choix parmi 17 types, dont interrupteur principal, RCD, RCBO, AFDD, SPD, fusibles, contacteurs, horloges, compteurs d’énergie et appareils KNX",[41,11053,11054,11057],{},[59,11055,11056],{},"Valeurs lisibles",[59,11058,11059],{},"Courant (A), pôles, courbe de déclenchement (B, C, D, K, Z), sensibilité (mA) et type de différentiel (A, B, F, AC), uniquement si elles sont lisibles",[41,11061,11062,11065],{},[59,11063,11064],{},"Marquage",[59,11066,11067],{},"Le texte lu apparaît sous le module dans la liste de vérification",[41,11069,11070,11073],{},[59,11071,11072],{},"Module illisible",[59,11074,11075,11076,11079],{},"Type ",[19,11077,11078],{},"Module DIN inconnu",", pour conserver malgré tout la position et la largeur",[41,11081,11082,11085],{},[59,11083,11084],{},"Câblage, circuits, chemin de protection",[59,11086,11087,11090],{},[19,11088,11089],{},"Non détectés."," Les conducteurs invisibles, les ponts et les affectations électriques ne sont pas déduits",[41,11092,11093,11096],{},[59,11094,11095],{},"Dimensions du coffret et valeurs standard",[59,11097,11098,11101],{},[19,11099,11100],{},"Non supposées."," La détection n’invente ni taille de coffret ni calibre usuel",[10,11103,11104],{},"Le texte imprimé sur une photo est traité uniquement comme contenu d’image. Il ne pilote pas la détection.",[10,11106,11107],{},[26,11108],{"id":11109},"photos",[30,11111,11113],{"id":11112},"comment-importer-et-associer-les-photos","Comment importer et associer les photos ?",[261,11115,11116,11128,11140,11149,11152],{},[152,11117,11118,11119,11121,11122,4951,11125,4014],{},"Dans le studio, ouvrez la zone ",[19,11120,4480],{}," et choisissez, dans le sélecteur de tableau de la barre supérieure, le tableau à relever. S’il n’existe pas encore, créez-le via ",[19,11123,11124],{},"Autres actions du tableau",[19,11126,11127],{},"Nouveau tableau",[152,11129,11130,11131,11133,11134,4551,11136,11139],{},"Restez dans le mode ",[19,11132,10931],{}," et cliquez sur ",[19,11135,10921],{},[19,11137,11138],{},"Photos du tableau"," s’ouvre à droite.",[152,11141,4017,11142,11145,11146,11148],{},[19,11143,11144],{},"Importer des photos"," et choisissez une ou plusieurs images. Les photos sont enregistrées dans les ",[19,11147,711],{}," et associées automatiquement à ce tableau.",[152,11150,11151],{},"Pour une photo déjà présente dans le projet, cochez la case devant son nom. Si le panneau affiche « Aucune photo de projet correspondante. », le projet ne contient encore aucune image JPEG, PNG ou WebP.",[152,11153,11154],{},"Vérifiez les onglets au-dessus de l’aperçu : chaque photo associée a son propre onglet. Un clic affiche la photo dans le panneau.",[10,11156,11157],{},"Critère de réussite : les photos voulues sont cochées et apparaissent en onglets. À la septième photo, PlanElec affiche « Sélectionnez au plus 6 photos. » et ne l’associe pas.",[390,11159,11161],{"id":11160},"quelles-photos-aident-la-détection","Quelles photos aident la détection ?",[149,11163,11164,11170,11179,11185],{},[152,11165,11166,11169],{},[19,11167,11168],{},"Un seul tableau par détection."," Toutes les photos associées montrent le même tableau ; la détection les traite comme des vues d’un seul coffret.",[152,11171,11172,11175,11176,4014],{},[19,11173,11174],{},"Combiner vue d’ensemble et gros plans."," Si plusieurs photos montrent le même module, la détection réunit ces vues en un seul module avec plusieurs ",[19,11177,11178],{},"vues photo",[152,11180,11181,11184],{},[19,11182,11183],{},"Marquages lisibles."," PlanElec ne reprend des valeurs comme le courant assigné ou la sensibilité que si elles sont lisibles sur la photo. Ce qui est masqué ou flou reste vide.",[152,11186,11187,11190,11191,4014],{},[19,11188,11189],{},"Les originaux sont conservés."," Pour l’analyse, PlanElec réduit chaque photo à 3200 pixels au maximum sur le plus grand côté. L’original reste dans les pièces du projet et fournit l’",[19,11192,11193],{},"Extrait en résolution originale",[10,11195,11196],{},"Le panneau le rappelle : les photos sélectionnées sont envoyées au service IA pour analyse. Associez donc uniquement des photos que vous pouvez utiliser à cette fin.",[10,11198,11199],{},[26,11200],{"id":11201},"recognise",[30,11203,11205],{"id":11204},"comment-lancer-la-détection","Comment lancer la détection ?",[261,11207,11208,11211,11216],{},[152,11209,11210],{},"Vérifiez que le bon tableau est sélectionné et que les photos adéquates sont associées.",[152,11212,4017,11213,11215],{},[19,11214,10993],{},". Pendant l’analyse, le bouton affiche « Détection en cours … ».",[152,11217,11218,11219,11222],{},"Attendez le message « Détection prête à vérifier. » Des cadres entourent alors les modules détectés sur la photo, et la zone ",[19,11220,11221],{},"Vérifier les modules détectés"," apparaît en dessous.",[10,11224,11225],{},"Chaque détection qui atteint le service IA compte dans la limite de 20 par jour, même si aucune proposition exploitable n’en ressort. Si votre quota IA ne suffit pas, PlanElec l’indique explicitement, par exemple « Votre quota IA restant est insuffisant pour cette analyse. »",[10,11227,11228],{},"Si vous fermez le panneau avant d’importer, la dernière proposition de ce tableau reste enregistrée. À la prochaine ouverture, PlanElec la recharge, mais dans sa forme d’origine : les corrections faites dans la liste de vérification sans être importées sont alors perdues.",[10,11230,11231],{},[26,11232],{"id":10272},[30,11234,11236],{"id":11235},"comment-vérifier-et-corriger-la-proposition","Comment vérifier et corriger la proposition ?",[10,11238,11239,11240,11242,11243,11245],{},"La zone ",[19,11241,11221],{}," liste chaque module détecté avec ses champs. Un clic sur un cadre de la photo sélectionne le module correspondant ; l’",[19,11244,11193],{}," l’affiche en grand. Vous comparez ainsi marquage et valeurs directement avec l’original.",[35,11247,11248,11257],{},[38,11249,11250],{},[41,11251,11252,11255],{},[44,11253,11254],{},"Champ ou action",[44,11256,10523],{},[54,11258,11259,11269,11278,11288,11298,11308,11324,11338,11348,11362],{},[41,11260,11261,11266],{},[59,11262,11263],{},[19,11264,11265],{},"Libellé",[59,11267,11268],{},"Nom du module dans le tableau. S’il reste vide, PlanElec utilise le nom du type de module",[41,11270,11271,11275],{},[59,11272,11273],{},[19,11274,11048],{},[59,11276,11277],{},"Corriger le type, par exemple si un RCBO a été détecté comme disjoncteur",[41,11279,11280,11285],{},[59,11281,11282],{},[19,11283,11284],{},"Rangée",[59,11286,11287],{},"Rail DIN compté depuis le haut ; 1 est la rangée supérieure",[41,11289,11290,11295],{},[59,11291,11292],{},[19,11293,11294],{},"Emplacement",[59,11296,11297],{},"Position en TE depuis le bord gauche de la rangée ; 0 est la première place, les demi-pas comme 2,5 sont possibles",[41,11299,11300,11305],{},[59,11301,11302],{},[19,11303,11304],{},"Largeur (TE)",[59,11306,11307],{},"Largeur du module par pas de 0,5 TE",[41,11309,11310,11321],{},[59,11311,11312,4004,11315,4004,11318],{},[19,11313,11314],{},"Courant (A)",[19,11316,11317],{},"Pôles",[19,11319,11320],{},"Sensibilité (mA)",[59,11322,11323],{},"Vérifier, compléter ou vider les valeurs relevées",[41,11325,11326,11335],{},[59,11327,11328,4004,11331,11334],{},[19,11329,11330],{},"Vue photo 1",[19,11332,11333],{},"2"," …",[59,11336,11337],{},"Affiche la photo sur laquelle le module apparaît à cet endroit",[41,11339,11340,11345],{},[59,11341,11342],{},[19,11343,11344],{},"Rejeter",[59,11346,11347],{},"Retire une ligne erronée de la proposition",[41,11349,11350,11359],{},[59,11351,11352,11355,11356],{},[19,11353,11354],{},"Fusionner avec le module"," + ",[19,11357,11358],{},"Fusionner",[59,11360,11361],{},"Réunit deux lignes qui montrent le même module physique sur des photos différentes",[41,11363,11364,11369],{},[59,11365,11366],{},[19,11367,11368],{},"Séparer",[59,11370,11371],{},"Détache la dernière vue photo en module distinct lorsque deux modules différents ont été réunis",[10,11373,11374],{},"Procédez ainsi :",[261,11376,11377,11380,11383,11386],{},[152,11378,11379],{},"Parcourez la liste de haut en bas et comparez chaque module avec son cadre et son extrait.",[152,11381,11382],{},"Rejetez les lignes qui ne sont pas des modules et fusionnez les modules détectés en double.",[152,11384,11385],{},"Corrigez le type, la rangée, l’emplacement et la largeur. S’il manque une rangée ou un emplacement, le panneau affiche « Indiquez une rangée et un emplacement pour chaque module. »",[152,11387,11388],{},"Vérifiez les valeurs relevées. PlanElec ne reprend la courbe de déclenchement et le type de différentiel que s’ils étaient lisibles ; ils ne sont pas modifiables comme champs distincts dans la liste de vérification.",[10,11390,11391],{},"Critère de réussite : chaque module restant a une rangée et un emplacement, et aucun module ne se chevauche dans une même rangée.",[10,11393,11394],{},[26,11395],{"id":10604},[30,11397,11399],{"id":11398},"que-se-passe-t-il-avec-importer-les-modules-vérifiés","Que se passe-t-il avec « Importer les modules vérifiés » ?",[261,11401,11402,11409],{},[152,11403,11404,11405,11408],{},"Sous la liste de vérification, cliquez sur ",[19,11406,11407],{},"Importer les modules vérifiés",". Le bouton est actif dès qu’il reste au moins un module, que chaque module a une rangée et un emplacement et que le tableau est vide.",[152,11410,11411],{},"PlanElec affiche « Modules importés. » Les modules occupent maintenant leur place dans le tableau.",[10,11413,11414],{},"Lors de l’import :",[149,11416,11417,11425,11431,11437],{},[152,11418,11419,331,11422,11424],{},[19,11420,11421],{},"Une seule étape d’annulation.",[19,11423,4893],{}," reprend l’ensemble de l’import en une fois.",[152,11426,11427,11430],{},[19,11428,11429],{},"Les rangées sont complétées, pas remplacées."," Si le tableau compte moins de rangées que la détection, PlanElec ajoute celles qui manquent. Les rangées existantes, même renommées, sont conservées.",[152,11432,11433,11436],{},[19,11434,11435],{},"La largeur des rangées s’adapte."," Si la place par rangée ne suffit pas, PlanElec élargit les rangées jusqu’à l’occupation importée la plus large. Une rangée ne peut pas dépasser 72 TE.",[152,11438,11439,11442],{},[19,11440,11441],{},"Les photos restent associées."," Chaque module importé garde ses vues photo comme justificatif.",[10,11444,11445],{},"Si « Impossible d’importer les modules. » s’affiche, deux modules se chevauchent généralement dans une même rangée, un module dépasse 72 TE ou le tableau n’est plus vide. Corrigez les valeurs et réessayez.",[10,11447,11448],{},"C’est vous qui lancez l’import, dans le panneau. L’assistant PlanElec ne peut ni associer des photos ni importer une proposition photo, car cette étape exige un contrôle visuel dans l’éditeur.",[10,11450,11451],{},[26,11452],{"id":11453},"next-steps",[30,11455,11457],{"id":11456},"que-faire-après-limport","Que faire après l’import ?",[10,11459,11460,11461,11464],{},"Les modules importés représentent l’",[19,11462,11463],{},"existant physique"," du tableau. Ils affichent les valeurs relevées, par exemple « C16 », mais ne sont pas encore intégrés électriquement : ils n’ont ni bornes de raccordement, ni circuit, ni chemin de protection.",[35,11466,11467,11475],{},[38,11468,11469],{},[41,11470,11471,11473],{},[44,11472,8899],{},[44,11474,7692],{},[54,11476,11477,11491,11505,11518],{},[41,11478,11479,11482],{},[59,11480,11481],{},"Revérifier un module sur la photo",[59,11483,11484,11485,11487,11488,11490],{},"Laissez le panneau ",[19,11486,11138],{}," ouvert et survolez un module importé en ",[19,11489,10931],{}," : le panneau affiche son extrait de photo",[41,11492,11493,11496],{},[59,11494,11495],{},"Définir circuits et chemins de protection",[59,11497,11498,11499,11501,11502],{},"Zone ",[19,11500,4458],{}," ; voir ",[26,11503,4495],{"href":11504},"\u002Ffr\u002Fhelp\u002Fplanifier-installation-et-tableaux-secondaires#assignment",[41,11506,11507,11510],{},[59,11508,11509],{},"Vérifier l’occupation des rangées et le coffret",[59,11511,11512,11513,11501,11515],{},"Mode ",[19,11514,10931],{},[26,11516,9039],{"href":11517},"\u002Ffr\u002Fhelp\u002Fplanifier-installation-et-tableaux-secondaires#cabinet",[41,11519,11520,11523],{},[59,11521,11522],{},"Réorganiser automatiquement",[59,11524,11525,11528],{},[19,11526,11527],{},"Auto-Répartition"," reconstruit entièrement le tableau après confirmation et remplace ainsi la disposition photographiée",[10,11530,11531,11532,11534,11535,4014],{},"Pour conserver la disposition photographiée, n’utilisez pas ",[19,11533,11527],{}," sur ce tableau. Le fonctionnement de l’Auto-Répartition est décrit dans ",[26,11536,4491],{"href":4490},[10,11538,11539],{},"Un existant importé est un état de planification, pas un relevé avec des mesures. Ce qui se trouve derrière les capots, le cheminement des conducteurs et le dimensionnement correct des protections se vérifient sur place. Le contrôle de conformité selon le RGIE est réalisé par l’organisme agréé.",[10,11541,11542],{},[26,11543],{"id":180},[30,11545,11547],{"id":11546},"quels-messages-et-quelles-limites","Quels messages et quelles limites ?",[35,11549,11550,11560],{},[38,11551,11552],{},[41,11553,11554,11557],{},[44,11555,11556],{},"Message ou situation",[44,11558,11559],{},"Cause et solution",[54,11561,11562,11574,11582,11590,11598,11606,11614],{},[41,11563,11564,11569],{},[59,11565,4595,11566,11568],{},[19,11567,10921],{}," n’apparaît pas",[59,11570,11571,11572],{},"Le projet n’est pas encore enregistré, ou vous n’êtes pas en mode ",[19,11573,10931],{},[41,11575,11576,11579],{},[59,11577,11578],{},"« La détection est disponible uniquement pour un tableau vide. »",[59,11580,11581],{},"Des modules sont placés ou des appareils sont affectés à ce tableau. Choisissez un tableau vide ou créez-en un nouveau",[41,11583,11584,11587],{},[59,11585,11586],{},"« Sélectionnez au plus 6 photos. »",[59,11588,11589],{},"Décochez d’abord une autre photo avant d’en associer une nouvelle",[41,11591,11592,11595],{},[59,11593,11594],{},"« Impossible de détecter les modules sur les photos. »",[59,11596,11597],{},"Le service IA n’a pas renvoyé de proposition valide, ou votre limite de 20 détections par jour est atteinte. Réessayez plus tard ; la limite repart à minuit UTC",[41,11599,11600,11603],{},[59,11601,11602],{},"Message relatif au quota IA",[59,11604,11605],{},"Votre quota IA personnel est insuffisant ou réservé pour une analyse en cours. Le menu utilisateur en affiche l’état",[41,11607,11608,11611],{},[59,11609,11610],{},"« Photo indisponible »",[59,11612,11613],{},"Le fichier a été retiré des pièces du projet ou ne peut pas être chargé. Associez une autre photo",[41,11615,11616,11619],{},[59,11617,11618],{},"« Impossible d’importer les modules. »",[59,11620,11621],{},"Chevauchement dans une rangée, position au-delà de 72 TE ou tableau qui n’est plus vide",[10,11623,11624,11625,11627,11628,4014],{},"D’autres situations courantes sont traitées dans ",[26,11626,4705],{"href":4764},". La reconnaissance de plans à partir de PDF et d’images est décrite dans ",[26,11629,11630],{"href":123},"Reconnaître un plan avec l’IA",{"title":822,"searchDepth":823,"depth":823,"links":11632},[11633,11634,11635,11638,11639,11640,11641,11642],{"id":10897,"depth":823,"text":10898},{"id":11002,"depth":823,"text":11003},{"id":11112,"depth":823,"text":11113,"children":11636},[11637],{"id":11160,"depth":831,"text":11161},{"id":11204,"depth":823,"text":11205},{"id":11235,"depth":823,"text":11236},{"id":11398,"depth":823,"text":11399},{"id":11456,"depth":823,"text":11457},{"id":11546,"depth":823,"text":11547},"PlanElec détecte sur six photos au maximum les modules DIN visibles avec leur rangée, leur emplacement, leur largeur et leur type, puis les propose pour un tableau vide. Vous vérifiez chaque module et importez l’ensemble en une seule étape annulable.","cabinet-photo-recognition","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fcabinet-photo-recognition.webp",{},13,"\u002Fhelp\u002Fcabinet-photo-recognition.fr",{"title":10878,"description":11643},"Reconnaître un tableau et ses modules DIN depuis des photos","reconnaitre-un-tableau-depuis-une-photo","help\u002Fcabinet-photo-recognition.fr",[5151,11654,9497,11655,11656],"photo","modules DIN","installation existante","s22qbQXPjlWV9CJ2WdbHC3GlWsXRdF7QiKCkzRr3VA0",{"id":11659,"title":11660,"body":11661,"category":12654,"description":12655,"extension":846,"guideId":12656,"image":12657,"locale":849,"meta":12658,"navigation":851,"order":12659,"path":12660,"publishedAt":6105,"readTime":5142,"seo":12661,"seoTitle":12662,"slug":12663,"stem":12664,"tags":12665,"updatedAt":6105,"__hash__":12671},"help\u002Fhelp\u002Fpv-planning.fr.md","Comment planifier une installation photovoltaïque dans PlanElec ?",{"type":7,"value":11662,"toc":12642},[11663,11672,11677,11681,11802,11805,11810,11814,11882,11885,11890,11894,11956,11961,12049,12056,12063,12067,12071,12078,12101,12104,12152,12156,12160,12172,12256,12263,12266,12284,12289,12293,12339,12342,12416,12419,12446,12449,12454,12458,12490,12493,12498,12502,12509,12520,12527,12531,12535,12544,12565,12569,12573,12634],[10,11664,11665,11666,11668,11669,11671],{},"Dans PlanElec, une installation photovoltaïque se planifie dans le mode ",[19,11667,4306],{}," du studio : vous posez des champs de modules sur les pans de toiture dans la vue 3D, vous ajoutez un onduleur dans le panneau ",[19,11670,4309],{}," et vous affectez les modules en strings à ses entrées MPPT. Il vous faut un plan avec toiture et une installation comportant au moins un dispositif de protection auquel l’onduleur sera raccordé. Vous obtenez un générateur PV documenté dans le schéma unifilaire, un symbole par string sur le plan de position, une prévision de rendement basée sur PVGIS et un registre de planification PV dans le rapport d’auto-contrôle. Le contrôle des strings compare les données de modules et d’onduleur que vous documentez ; la stabilité, l’ombrage par les objets environnants et la vérification de l’installation réalisée restent hors de PlanElec. Le contrôle de conformité relève de l’organisme agréé.",[10,11673,11674],{},[26,11675],{"id":11676},"overview",[30,11678,11680],{"id":11679},"quelles-sont-les-étapes-dune-planification-pv","Quelles sont les étapes d’une planification PV ?",[35,11682,11683,11696],{},[38,11684,11685],{},[41,11686,11687,11690,11693],{},[44,11688,11689],{},"Étape",[44,11691,11692],{},"Où dans PlanElec",[44,11694,11695],{},"Résultat",[54,11697,11698,11714,11729,11745,11762,11776,11791],{},[41,11699,11700,11703,11711],{},[59,11701,11702],{},"Toiture et champs de modules",[59,11704,11512,11705,11707,11708],{},[19,11706,4306],{},", vue 3D, barre ",[19,11709,11710],{},"Modules PV",[59,11712,11713],{},"Champs avec type de module, orientation et type de montage",[41,11715,11716,11719,11726],{},[59,11717,11718],{},"Onduleur et MPPT",[59,11720,7702,11721,4951,11723],{},[19,11722,4309],{},[19,11724,11725],{},"Ajouter un onduleur",[59,11727,11728],{},"Onduleur sur un circuit dédié, avec ses entrées MPPT",[41,11730,11731,11734,11742],{},[59,11732,11733],{},"Former les strings",[59,11735,11736,293,11739],{},[19,11737,11738],{},"Affecter les strings",[19,11740,11741],{},"Répartir automatiquement",[59,11743,11744],{},"Strings par MPPT, avec contrôle en direct des limites",[41,11746,11747,11750,11759],{},[59,11748,11749],{},"String sur le plan de position",[59,11751,11752,11753,4951,11756],{},"Palette d’appareils ",[19,11754,11755],{},"Production",[19,11757,11758],{},"Panneau solaire \u002F module PV",[59,11760,11761],{},"Exactement un symbole par string, lié à l’onduleur",[41,11763,11764,11767,11773],{},[59,11765,11766],{},"Côté PV du schéma unifilaire",[59,11768,11769,11770,11772],{},"Sélectionner l’onduleur dans le ",[19,11771,569],{},", inspecteur",[59,11774,11775],{},"Protection DC, point de sectionnement AC, câbles et PE des cadres",[41,11777,11778,11781,11788],{},[59,11779,11780],{},"Prévision de rendement",[59,11782,7702,11783,4951,11785],{},[19,11784,4309],{},[19,11786,11787],{},"Prévision de rendement PV",[59,11789,11790],{},"Production annuelle et mensuelle, P50\u002FP90, chaîne de pertes, rapport",[41,11792,11793,11795,11799],{},[59,11794,4554],{},[59,11796,11797],{},[19,11798,3930],{},[59,11800,11801],{},"Rapport d’auto-contrôle avec registre PV, rapport de rendement PV, liste de matériel (pilote)",[10,11803,11804],{},"Cet ordre n’est qu’une proposition. Vous pouvez aussi créer l’onduleur d’abord dans le schéma unifilaire et poser les modules ensuite.",[10,11806,11807],{},[26,11808],{"id":11809},"roof-fields",[30,11811,11813],{"id":11812},"comment-poser-des-champs-de-modules-sur-la-toiture","Comment poser des champs de modules sur la toiture ?",[261,11815,11816,11826,11851,11872],{},[152,11817,11818,11819,11821,11822,11825],{},"Ouvrez le mode ",[19,11820,4306],{}," dans le studio. La vue 3D montre tout le bâtiment avec sa toiture. PlanElec déduit les pans du plan ; dans la barre de toiture, vous choisissez la ",[19,11823,11824],{},"Forme de toiture"," et la pente.",[152,11827,11828,11829,11831,11832,11835,11836,11838,11839,11842,11843,11846,11847,11850],{},"Dans la barre ",[19,11830,11710],{},", choisissez un outil de pose : ",[19,11833,11834],{},"Module individuel"," (un clic), ",[19,11837,11284],{}," (tracer une ligne), ",[19,11840,11841],{},"Champ"," (tracer un rectangle) ou ",[19,11844,11845],{},"Toute la surface de toit"," (cliquer sur un pan, qui est entièrement couvert). Avec l’interrupteur ",[19,11848,11849],{},"Meilleure disposition",", un clic sur le pan ouvre les meilleures variantes de format.",[152,11852,11853,11854,11857,11858,4004,11861,293,11864,11867,11868,11871],{},"Réglez d’abord les préférences des nouveaux champs : portrait ou paysage et, sur toit plat, ",[19,11855,11856],{},"Montage toit plat"," (",[19,11859,11860],{},"À plat (0°)",[19,11862,11863],{},"Surélevé sud",[19,11865,11866],{},"Est-ouest",") avec l’",[19,11869,11870],{},"Inclinaison (°)",". Sur toit incliné, les modules sont posés parallèlement au toit.",[152,11873,11874,11875,11878,11879,11881],{},"Cliquez sur un champ avec ",[19,11876,11877],{},"Sélectionner",". Dans le menu du champ, choisissez le ",[19,11880,11048],{}," dans le catalogue ; sa puissance et ses dimensions alimentent la planification des strings et la prévision de rendement. Un glisser déplace le champ, les poignées le redimensionnent dans la grille des modules, la touche Suppr le supprime.",[10,11883,11884],{},"Critère de réussite : la barre affiche le nombre total de modules et la puissance installée en kWc. Chaque opération sur un champ constitue une seule étape d’annulation. Dans la prévision de rendement, un champ sans type de module est calculé avec un module standard ; les dimensions supposées y sont signalées.",[10,11886,11887],{},[26,11888],{"id":11889},"inverter-strings",[30,11891,11893],{"id":11892},"comment-créer-londuleur-les-mppt-et-les-strings","Comment créer l’onduleur, les MPPT et les strings ?",[261,11895,11896,11904,11930,11937,11950],{},[152,11897,7620,11898,7623,11900,11133,11902,4014],{},[19,11899,4306],{},[19,11901,4309],{},[19,11903,11725],{},[152,11905,11906,11907,11910,11911,11914,11915,11918,11919,11922,11923,11926,11927,4014],{},"Dans la boîte de dialogue, cherchez sous ",[19,11908,11909],{},"Catalogue vérifié"," ou dans la ",[19,11912,11913],{},"Liste Synergrid (tous les onduleurs homologués)",", puis reprenez l’appareil avec ",[19,11916,11917],{},"Ajouter au projet",". Si votre modèle n’y figure pas, choisissez ",[19,11920,11921],{},"Créer sans catalogue",". Les valeurs fabricant manquantes restent vides et ne sont jamais inventées ; complétez les limites de tension sous ",[19,11924,11925],{},"Données de l’appareil"," et les limites de courant de chaque MPPT sous ",[19,11928,11929],{},"Modifier les limites",[152,11931,11932,11933,11936],{},"PlanElec raccorde l’onduleur à un circuit PV dédié. Un disjoncteur déjà attribué à une source de production est réutilisé. Sinon, un nouveau ",[19,11934,11935],{},"Disjoncteur onduleur PV"," (valeur par défaut C 25 A, bipolaire) est créé sous le premier différentiel. Adaptez son calibre au courant AC nominal de votre onduleur. En l’absence de tout dispositif de protection, PlanElec indique qu’il faut d’abord un tableau avec un disjoncteur.",[152,11938,11939,11940,11943,11944,11946,11947,11949],{},"Dans une section MPPT, cliquez sur ",[19,11941,11942],{},"Affecter des modules",", ou sur ",[19,11945,11738],{}," dans la barre ",[19,11948,11710],{},". Un bandeau affiche le MPPT, la longueur de string admise et les raccourcis clavier.",[152,11951,11952,11953,11955],{},"Cliquez sur les modules dans l’ordre de la chaîne. La pastille de champ reprend tous les modules libres d’un champ en serpentin. ",[19,11954,4640],{}," crée le string, Maj+Entrée crée un string parallèle sur le même MPPT, Échap abandonne le brouillon, Retour arrière retire le dernier module.",[10,11957,11958,11960],{},[19,11959,11741],{}," distribue en une seule étape tous les modules libres. Le résumé indique les strings créés par champ et par MPPT, ainsi que les raisons pour lesquelles des modules restent libres, par exemple un courant de module trop élevé pour un MPPT.",[35,11962,11963,11975],{},[38,11964,11965],{},[41,11966,11967,11970,11973],{},[44,11968,11969],{},"Contrôle pendant l’affectation",[44,11971,11972],{},"Référence",[44,11974,484],{},[54,11976,11977,11988,11998,12008,12018,12028,12038],{},[41,11978,11979,11982,11985],{},[59,11980,11981],{},"Voc à froid à −10 °C",[59,11983,11984],{},"tension DC max. de l’onduleur, tension système du module",[59,11986,11987],{},"Erreur, bloque Entrée",[41,11989,11990,11993,11996],{},[59,11991,11992],{},"Vmpp à chaud à +70 °C",[59,11994,11995],{},"minimum MPPT",[59,11997,11987],{},[41,11999,12000,12003,12006],{},[59,12001,12002],{},"Σ Imp, Σ Isc des strings parallèles",[59,12004,12005],{},"limites de courant du MPPT",[59,12007,11987],{},[41,12009,12010,12013,12016],{},[59,12011,12012],{},"nombre de strings parallèles",[59,12014,12015],{},"nombre max. de strings parallèles du MPPT",[59,12017,11987],{},[41,12019,12020,12023,12026],{},[59,12021,12022],{},"Vmpp à froid, tension de démarrage",[59,12024,12025],{},"maximum MPPT, tension de démarrage",[59,12027,6311],{},[41,12029,12030,12033,12036],{},[59,12031,12032],{},"pans, orientations ou longueurs mélangés",[59,12034,12035],{},"strings sur le même MPPT",[59,12037,6311],{},[41,12039,12040,12043,12046],{},[59,12041,12042],{},"caractéristiques manquantes",[59,12044,12045],{},"données du module ou de l’onduleur",[59,12047,12048],{},"Information « vérification incomplète »",[10,12050,12051,12052,12055],{},"Vous pouvez créer volontairement un string bloqué avec ",[19,12053,12054],{},"Créer quand même"," (Ctrl\u002F⌘+Entrée) ; le constat reste affiché. Si le brouillon est trop long, le bandeau propose une répartition régulière sur plusieurs strings. Pour les micro-onduleurs et les optimiseurs, le contrôle indique « non applicable », car les règles du fabricant s’appliquent.",[10,12057,12058,12059,12062],{},"La section ",[19,12060,12061],{},"Conflits"," compte les modules sans string, les références de modules introuvables, les strings répartis sur plusieurs pans et les strings mêlant plusieurs types de modules. PlanElec ne corrige pas ces conflits en silence : vous adaptez le string ou relancez la répartition.",[10,12064,12065],{},[26,12066],{"id":4230},[30,12068,12070],{"id":12069},"comment-un-string-apparaît-il-sur-le-plan-de-position","Comment un string apparaît-il sur le plan de position ?",[10,12072,12073,12074,12077],{},"Sur le plan de position, un symbole de module représente ",[19,12075,12076],{},"un string complet",", pas un module isolé. Chaque string d’un onduleur doit avoir exactement un symbole.",[261,12079,12080,12091,12098],{},[152,12081,4415,12082,12084,12085,12087,12088,12090],{},[19,12083,4091],{}," et choisissez dans la palette d’appareils, sous ",[19,12086,11755],{},", le symbole ",[19,12089,11758],{},". Placez-le à l’emplacement du champ sur le plan.",[152,12092,12093,12094,12097],{},"Sélectionnez le symbole. Dans sa barre d’outils, ouvrez ",[19,12095,12096],{},"Sélectionner un string PV"," et choisissez l’entrée « onduleur · string ».",[152,12099,12100],{},"Répétez l’opération pour chaque string. S’il n’existe encore aucun string, la barre vous invite d’abord à ajouter un onduleur avec des strings PV.",[10,12102,12103],{},"Le symbole porte alors une étiquette avec le string, le nombre de modules, la puissance par module et les kWc. L’auto-contrôle signale chaque écart :",[35,12105,12106,12119],{},[38,12107,12108],{},[41,12109,12110,12113,12116],{},[44,12111,12112],{},"Message",[44,12114,12115],{},"Cause",[44,12117,12118],{},"Niveau",[54,12120,12121,12132,12142],{},[41,12122,12123,12126,12129],{},[59,12124,12125],{},"« … manque dans le plan de position »",[59,12127,12128],{},"un string documenté n’a pas de symbole",[59,12130,12131],{},"Information, donnée manquante",[41,12133,12134,12137,12140],{},[59,12135,12136],{},"« … est attribué n fois dans le plan de position »",[59,12138,12139],{},"plusieurs symboles renvoient au même string",[59,12141,6311],{},[41,12143,12144,12147,12150],{},[59,12145,12146],{},"« Symbole PV sans attribution valide à un string »",[59,12148,12149],{},"le symbole n’a pas de string, ou un string qui n’existe plus",[59,12151,12131],{},[10,12153,12154],{},[26,12155],{"id":5796},[30,12157,12159],{"id":12158},"que-montre-le-côté-pv-du-schéma-unifilaire","Que montre le côté PV du schéma unifilaire ?",[10,12161,12162,12163,12165,12166,4951,12168,12171],{},"Sélectionnez l’onduleur dans le ",[19,12164,569],{},". Vous pouvez aussi y créer un onduleur via le groupe de palette ",[19,12167,11755],{},[19,12169,12170],{},"Onduleur PV",". L’inspecteur répartit les données PV en cinq sections :",[35,12173,12174,12184],{},[38,12175,12176],{},[41,12177,12178,12181],{},[44,12179,12180],{},"Section de l’inspecteur",[44,12182,12183],{},"Ce que vous documentez",[54,12185,12186,12206,12216,12226,12246],{},[41,12187,12188,12193],{},[59,12189,12190],{},[19,12191,12192],{},"Onduleur et raccordement AC",[59,12194,12195,12196,4004,12199,12202,12203],{},"fabricant, type, ",[19,12197,12198],{},"Numéro de série",[19,12200,12201],{},"Puissance AC nominale (kW)",", limites de tension, mode de fonctionnement, interface batterie, phases AC, ",[19,12204,12205],{},"Conducteur de protection AC (mm²)",[41,12207,12208,12213],{},[59,12209,12210],{},[19,12211,12212],{},"Protection DC commune",[59,12214,12215],{},"sectionneur DC commun et parafoudre DC commun de type 2, chacun avec son statut d’installation",[41,12217,12218,12223],{},[59,12219,12220],{},[19,12221,12222],{},"Types de modules",[59,12224,12225],{},"données des modules issues du catalogue ou saisies",[41,12227,12228,12233],{},[59,12229,12230],{},[19,12231,12232],{},"MPPT et strings",[59,12234,12235,12238,12239,4004,12242,12245],{},[19,12236,12237],{},"Regroupement des strings"," (direct, dérivation en Y, combiner), ",[19,12240,12241],{},"Fusible de string",[19,12243,12244],{},"Parcours du câble DC"," et ses tronçons",[41,12247,12248,12253],{},[59,12249,12250],{},[19,12251,12252],{},"PE des cadres et de la structure porteuse",[59,12254,12255],{},"groupes équipotentiels avec prescription du fabricant, section, protection mécanique et longueur",[10,12257,12258,12259,12262],{},"Le schéma en tire les strings simples et parallèles par MPPT, la dérivation en Y ou le combiner, les protections avec leur statut, le ",[19,12260,12261],{},"Point de sectionnement AC",", les tronçons de câble documentés et le PE distinct des cadres jusqu’à la liaison à la terre. Les strings sans MPPT apparaissent sous « Chaînes CC non attribuées (ouvertes) ». Les limites fabricant manquantes restent visibles et ne sont pas complétées.",[10,12264,12265],{},"Pour le PE des cadres, le RGIE impose en 7.112.2 la mise à la terre des cadres métalliques des modules et de leurs structures, sauf interdiction du fabricant, par un conducteur de protection d’une section au moins égale à celle du conducteur de protection AC, avec un minimum de 2,5 mm² avec protection mécanique et de 4 mm² sans. L’auto-contrôle compare votre section à ce minimum. Si vous choisissez la prescription « Interdite par le fabricant », il attend une référence justificative.",[10,12267,12268,12271,12272,12275,12276,12279,12280,12283],{},[19,12269,12270],{},"Dériver les longueurs DC :"," dans la vue 3D, placez une ancre ",[19,12273,12274],{},"Traversée de toiture"," sur le toit et attribuez-la dans la ligne du string, sous ",[19,12277,12278],{},"Pénétration",". PlanElec dérive alors trois tronçons : sur le toit jusqu’à la traversée, verticalement à travers le plafond, puis dans le bâtiment jusqu’à l’onduleur. Une longueur saisie a priorité ; ",[19,12281,12282],{},"Rétablir la dérivation"," revient à la géométrie. S’il manque un tronçon, la longueur totale reste inconnue, jamais nulle. Le tronçon dans le bâtiment est une liaison directe ; un tracé personnalisé n’est pas encore possible.",[10,12285,12286],{},[26,12287],{"id":12288},"yield",[30,12290,12292],{"id":12291},"comment-calculer-la-prévision-de-rendement","Comment calculer la prévision de rendement ?",[261,12294,12295,12306,12320,12330],{},[152,12296,4723,12297,12299,12300,12302,12303,4014],{},[19,12298,4309],{},", dépliez la ",[19,12301,11787],{}," et ouvrez l’onglet ",[19,12304,12305],{},"Entrées",[152,12307,5031,12308,12311,12312,12315,12316,12319],{},[19,12309,12310],{},"Définir le site",". PlanElec reprend l’adresse de l’installation depuis les données du projet et recherche des adresses belges. Vérifiez la carte et le nord, cochez ",[19,12313,12314],{},"Confirmer le site et le nord"," puis cliquez sur ",[19,12317,12318],{},"Confirmer le site",". Sans cette confirmation, aucun calcul n’est lancé.",[152,12321,12322,12323,9914,12326,12329],{},"Vérifiez les ",[19,12324,12325],{},"Hypothèses",[19,12327,12328],{},"Pertes du système (%)"," (14 % par défaut), technologie des modules, type de montage, horizon (modèle de terrain de PVGIS ou aucun) et base de données de rayonnement.",[152,12331,4017,12332,12335,12336,12338],{},[19,12333,12334],{},"Calculer",". L’onglet ",[19,12337,11695],{}," affiche la production annuelle, la puissance, la production spécifique en kWh\u002FkWc et le graphique mensuel.",[10,12340,12341],{},"Le calcul utilise PVGIS 5.3 du Centre commun de recherche de l’UE, par groupe d’orientation. Seules les coordonnées et les paramètres physiques sont transmis, jamais de nom de projet ou de client.",[35,12343,12344,12354],{},[38,12345,12346],{},[41,12347,12348,12351],{},[44,12349,12350],{},"Indicateur du résultat",[44,12352,12353],{},"Ce qu’il recouvre",[54,12355,12356,12366,12376,12386,12396,12406],{},[41,12357,12358,12363],{},[59,12359,12360],{},[19,12361,12362],{},"P50 (médiane)",[59,12364,12365],{},"médiane des productions annuelles des années individuelles de la base PVGIS",[41,12367,12368,12373],{},[59,12369,12370],{},[19,12371,12372],{},"P90 (atteint 9 années sur 10)",[59,12374,12375],{},"10e centile de ces mêmes années ; sur environ 19 ans, une estimation sur un petit échantillon",[41,12377,12378,12383],{},[59,12379,12380],{},[19,12381,12382],{},"Production avec pertes forfaitaires",[59,12384,12385],{},"production avec le forfait de pertes du système",[41,12387,12388,12393],{},[59,12389,12390],{},[19,12391,12392],{},"Production affinée",[59,12394,12395],{},"forfait réparti : courbe de l’onduleur et câblage DC issus de votre planification, autres pertes en reste",[41,12397,12398,12403],{},[59,12399,12400],{},[19,12401,12402],{},"Écrêtage",[59,12404,12405],{},"limitation à la puissance AC nominale, par onduleur en kWh\u002Fan, en part et en heures",[41,12407,12408,12413],{},[59,12409,12410],{},[19,12411,12412],{},"Évolution de la production sur 25 ans",[59,12414,12415],{},"garanties du module, sinon l’hypothèse signalée de 0,5 % de perte de puissance par an",[10,12417,12418],{},"La chaîne de pertes nécessite un onduleur avec des strings. Sans puissance AC nominale, elle calcule sans écrêtage, avec un rendement constant. Sans rendement vérifié, l’hypothèse signalée de 96 % s’applique. Pour la perte dans le câblage DC, comptent la longueur, la section saisie dans l’inspecteur et la tension du module ; s’il manque un élément, le string est calculé à 2 % et la raison est indiquée. Si une batterie est documentée sur l’onduleur, l’écrêtage est une borne supérieure.",[10,12420,12421,12422,12425,12426,293,12429,12432,12433,12436,12437,12440,12441,12443,12444,4014],{},"Dans l’onglet ",[19,12423,12424],{},"Variantes",", vous comparez d’autres modules en ",[19,12427,12428],{},"Même disposition",[19,12430,12431],{},"Même surface"," ; les variantes ne modifient ni la planification ni les strings. Si vous modifiez la géométrie, le site, les hypothèses ou les strings, le résultat passe en ",[19,12434,12435],{},"Résultat obsolète"," et le rapport reste bloqué jusqu’au nouveau calcul. ",[19,12438,12439],{},"Ouvrir le rapport"," génère le ",[19,12442,5600],{}," à partir de l’état figé ; vous le trouvez aussi sous ",[19,12445,3930],{},[10,12447,12448],{},"Limites : P50 et P90 décrivent des années météo passées, pas une garantie de production. L’ombrage par les objets de la scène n’est pas pris en compte et il n’y a pas de calcul de rentabilité. Un groupe d’orientation en échec reste visible comme résultat partiel, jamais comme production nulle.",[10,12450,12451],{},[26,12452],{"id":12453},"self-consumption",[30,12455,12457],{"id":12456},"peut-on-estimer-lautoconsommation-la-batterie-et-la-voiture-électrique","Peut-on estimer l’autoconsommation, la batterie et la voiture électrique ?",[10,12459,12460,12461,12464,12465,12467,12468,12471,12472,12475,12476,4004,12478,12481,12482,12485,12486,12489],{},"Oui, comme ",[19,12462,12463],{},"fonction pilote"," au sein de la prévision de rendement. Dans l’onglet ",[19,12466,12305],{},", indiquez la consommation annuelle sous ",[19,12469,12470],{},"Consommation électrique"," et choisissez un profil ; sous ",[19,12473,12474],{},"Voiture électrique",", vous pouvez ajouter un ou deux véhicules. Dans l’onglet ",[19,12477,11695],{},[19,12479,12480],{},"Calculer l’autoconsommation"," lance le calcul d’une année type au quart d’heure : taux d’autoconsommation, taux d’autonomie, prélèvement sur le réseau et injection, par mois. La section ",[19,12483,12484],{},"Batterie domestique"," compare la situation sans et avec la batterie du projet et classe des capacités dans la ",[19,12487,12488],{},"Comparaison des tailles"," ; la proposition repose sur un seuil supposé.",[10,12491,12492],{},"Les profils sont des moyennes de ménages flamands (Fluvius, 2024), pas votre compteur ; pour la Wallonie et Bruxelles, la même courbe est supposée. Les pointes sont lissées, ce qui peut surestimer l’intérêt d’une batterie. Il n’y a ni tarifs, ni calcul d’économie ou d’amortissement, et ces indicateurs ne figurent ni dans le rapport de rendement ni dans le dossier.",[10,12494,12495],{},[26,12496],{"id":12497},"self-check-report",[30,12499,12501],{"id":12500},"que-contient-le-rapport-dauto-contrôle-pour-le-pv","Que contient le rapport d’auto-contrôle pour le PV ?",[10,12503,12504,12505,12508],{},"Dès que le projet contient un onduleur, le rapport d’auto-contrôle RGIE ajoute la section ",[19,12506,12507],{},"Données de l’installation PV pour le contrôle",". Elle est explicitement présentée comme un registre de planification propre au projet et non comme un rapport émis par un organisme agréé. Pour chaque onduleur, elle reprend :",[149,12510,12511,12514,12517],{},[152,12512,12513],{},"le nom, le fabricant et le modèle,",[152,12515,12516],{},"le numéro de série et la puissance AC maximale,",[152,12518,12519],{},"le générateur PV avec le nombre de modules, les kWc, le nombre de MPPT et de strings.",[10,12521,12522,12523,12526],{},"Vous disposez ainsi des données que le RGIE, en 7.112.4, demande de reprendre dans le rapport de contrôle de conformité d’une installation photovoltaïque domestique. Les valeurs non saisies apparaissent comme « Non renseigné ». Le rapport présente aussi les constats des règles PV, par exemple sur le PE des cadres selon le RGIE 7.112.2 ou sur la conception des strings. Les règles évaluées par PlanElec sont détaillées dans ",[26,12524,12525],{"href":4520},"Ce que vérifie l’auto-contrôle",". Si l’auto-contrôle est désactivé pour le projet, le rapport n’est pas disponible.",[10,12528,12529],{},[26,12530],{"id":5892},[30,12532,12534],{"id":12533},"que-reprend-la-liste-de-matériel-de-la-planification-pv","Que reprend la liste de matériel de la planification PV ?",[10,12536,12537,12538,12540,12541,12543],{},"La liste de matériel est une ",[19,12539,12463],{}," disponible sous ",[19,12542,3930],{},". Du côté DC, elle ne reprend que des données structurées : modules avec type et nombre, protections documentées explicitement comme présentes et tronçons de câble connus. Les conducteurs plus et moins comptent ensemble pour deux fois la longueur du trajet, un PE\u002FPA accompagnant le câble une seule fois. Les protections intégrées et un point de sectionnement AC assuré par la protection de source ne sont pas comptés deux fois.",[10,12545,5901,12546,12549,12550,4004,12553,4004,12556,293,12559,12562,12563,4014],{},[19,12547,12548],{},"Nomenclature de l’installation PV"," de l’aperçu du matériel ajoute les éléments de montage avec le statut ",[19,12551,12552],{},"Établi",[19,12554,12555],{},"Hypothèse",[19,12557,12558],{},"Ouvert",[19,12560,12561],{},"Dimensionné à l’extérieur",". Les lignes ouvertes montrent une lacune plutôt qu’une quantité nulle. Le comptage DC n’ajoute ni PE des cadres, ni connecteurs, ni réserves, ni chutes. La liste est neutre vis-à-vis des fabricants, sans prix, et ne constitue pas une liste de commande ; la stabilité et la fixation se dimensionnent avec le configurateur du fabricant ou par un ingénieur en stabilité. Voir aussi ",[26,12564,4615],{"href":4614},[10,12566,12567],{},[26,12568],{"id":180},[30,12570,12572],{"id":12571},"quest-ce-que-planelec-ne-prend-pas-en-charge-pour-le-pv","Qu’est-ce que PlanElec ne prend pas en charge pour le PV ?",[35,12574,12575,12584],{},[38,12576,12577],{},[41,12578,12579,12581],{},[44,12580,556],{},[44,12582,12583],{},"Qui ou quoi décide",[54,12585,12586,12594,12602,12610,12618,12626],{},[41,12587,12588,12591],{},[59,12589,12590],{},"stabilité, crochets de toiture, lestage",[59,12592,12593],{},"configurateur du fabricant ou ingénieur en stabilité",[41,12595,12596,12599],{},[59,12597,12598],{},"ombrage par les objets voisins",[59,12600,12601],{},"votre propre évaluation ; PVGIS ne tient compte que de l’horizon du relief",[41,12603,12604,12607],{},[59,12605,12606],{},"rôles des conducteurs DC L+, L-, M, PEM, PEL",[59,12608,12609],{},"non modélisés ; le choix des conducteurs et la surveillance d’isolement restent à vérifier par vous",[41,12611,12612,12615],{},[59,12613,12614],{},"homologations et certificats du fabricant",[59,12616,12617],{},"fiches techniques et documents du fabricant",[41,12619,12620,12623],{},[59,12621,12622],{},"raccordement et notification au réseau",[59,12624,12625],{},"gestionnaire de réseau de distribution (ORES, RESA, Sibelga)",[41,12627,12628,12631],{},[59,12629,12630],{},"contrôle de conformité",[59,12632,12633],{},"organisme agréé",[10,12635,12636,12637,12639,12640,4014],{},"Le circuit de l’onduleur se planifie comme tout autre circuit : voir ",[26,12638,10840],{"href":4494},". Pour placer et relier des symboles sur le plan de position, consultez ",[26,12641,4438],{"href":4437},{"title":822,"searchDepth":823,"depth":823,"links":12643},[12644,12645,12646,12647,12648,12649,12650,12651,12652,12653],{"id":11679,"depth":823,"text":11680},{"id":11812,"depth":823,"text":11813},{"id":11892,"depth":823,"text":11893},{"id":12069,"depth":823,"text":12070},{"id":12158,"depth":823,"text":12159},{"id":12291,"depth":823,"text":12292},{"id":12456,"depth":823,"text":12457},{"id":12500,"depth":823,"text":12501},{"id":12533,"depth":823,"text":12534},{"id":12571,"depth":823,"text":12572},"planning","Poser les modules sur les pans de toiture, affecter les strings aux MPPT, documenter le côté PV du schéma unifilaire et estimer la production avec PVGIS, limites comprises.","pv-planning","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fpv-planning-fr.webp",{},14,"\u002Fhelp\u002Fpv-planning.fr",{"title":11660,"description":12655},"Comment planifier une installation PV dans PlanElec ?","planifier-une-installation-photovoltaique","help\u002Fpv-planning.fr",[12666,12667,12668,12669,12670,5152,6102],"photovoltaïque","string PV","onduleur","MPPT","prévision de rendement","ElN3JDpb6couz1jQjqP6T3mM-q9rCsC-P0u0XjCRFGs",{"id":12673,"title":4610,"body":12674,"category":4529,"description":13463,"extension":846,"guideId":13464,"image":13465,"locale":849,"meta":13466,"navigation":851,"order":13467,"path":13468,"publishedAt":6105,"readTime":8008,"seo":13469,"seoTitle":13470,"slug":13471,"stem":13472,"tags":13473,"updatedAt":6105,"__hash__":13479},"help\u002Fhelp\u002Fdocument-archive-verification.fr.md",{"type":7,"value":12675,"toc":13450},[12676,12689,12694,12698,12706,12786,12789,12818,12824,12829,12833,12893,12901,12905,12909,12951,12957,12963,12966,12971,12975,13001,13007,13011,13015,13031,13092,13102,13107,13111,13129,13132,13137,13141,13151,13214,13225,13228,13233,13237,13240,13260,13263,13268,13272,13303,13313,13317,13321,13367,13377,13382,13386,13442],[10,12677,12678,12679,12681,12682,12684,12685,12688],{},"Avec ",[19,12680,4598],{}," dans l’espace ",[19,12683,3930],{},", PlanElec conserve un PDF sans modification dans l’archive du projet. Chaque version de remise reçoit un identifiant de document aléatoire, un numéro de version croissant par type de document, un code QR sur chaque page et une empreinte SHA-256. Conditions : le projet est enregistré, le document n’a plus de correction en attente et vous êtes Propriétaire, Administrateur ou Éditeur du projet. La personne qui scanne le code QR voit sur la page ",[19,12686,12687],{},"Vérification de document"," si cette version d’archive précise est actuelle, remplacée ou révoquée. Ce contrôle confirme uniquement l’origine d’archive et l’intégrité du fichier. Il ne constitue ni un contrôle RGIE, ni une déclaration de conformité, ni une signature électronique ; le contrôle de conformité relève de l’organisme agréé.",[10,12690,12691],{},[26,12692],{"id":12693},"document-types",[30,12695,12697],{"id":12696},"quels-documents-pouvez-vous-archiver","Quels documents pouvez-vous archiver ?",[10,12699,12700,12701,5053,12703,12705],{},"Est archivé chaque PDF que vous remettez dans ",[19,12702,3930],{},[19,12704,4598],{},". Le périmètre documenté couvre ces huit types de documents :",[35,12707,12708,12717],{},[38,12709,12710],{},[41,12711,12712,12715],{},[44,12713,12714],{},"Document dans Export",[44,12716,402],{},[54,12718,12719,12727,12735,12744,12752,12760,12768,12776],{},[41,12720,12721,12725],{},[59,12722,12723],{},[19,12724,569],{},[59,12726,5516],{},[41,12728,12729,12733],{},[59,12730,12731],{},[19,12732,643],{},[59,12734,5516],{},[41,12736,12737,12741],{},[59,12738,12739],{},[19,12740,5537],{},[59,12742,12743],{},"disponible, indicatif ; uniquement avec l’auto-contrôle activé",[41,12745,12746,12750],{},[59,12747,12748],{},[19,12749,5562],{},[59,12751,5571],{},[41,12753,12754,12758],{},[59,12755,12756],{},[19,12757,5565],{},[59,12759,5571],{},[41,12761,12762,12766],{},[59,12763,12764],{},[19,12765,5568],{},[59,12767,5571],{},[41,12769,12770,12774],{},[59,12771,12772],{},[19,12773,5550],{},[59,12775,5516],{},[41,12777,12778,12783],{},[59,12779,12780],{},[19,12781,12782],{},"Dossier d'installation",[59,12784,12785],{},"disponible ; validation sur de vrais projets clients en cours",[10,12787,12788],{},"Si Export affiche d’autres cartes de document avec le même bouton, elles suivent le même chemin d’archivage. Chaque type possède sa propre suite de versions : le dossier d’installation est numéroté séparément d’un schéma unifilaire remis seul.",[10,12790,12791,12794,12795,9914,12797,4004,12799,4004,12801,4004,12803,4004,12805,4004,12807,12809,12810,12813,12814,4014],{},[19,12792,12793],{},"Ne sont pas archivés"," les documents de la section ",[19,12796,4286],{},[19,12798,8344],{},[19,12800,8414],{},[19,12802,8422],{},[19,12804,8430],{},[19,12806,8438],{},[19,12808,8446],{}," et le ",[19,12811,12812],{},"Dossier de remise domotique"," sont générés dans le navigateur. Leur empreinte identifie seulement les données figées de l’export ; ce n’est pas une confirmation d’archivage. Voir ",[26,12815,12817],{"href":12816},"\u002Ffr\u002Fhelp\u002Fplanifier-et-documenter-le-knx","Planifier et documenter le KNX",[10,12819,12820,12821,12823],{},"Un téléchargement via ",[19,12822,4580],{}," n’entre pas non plus dans l’archive. Les brouillons portent la mention « BROUILLON » et restent des fichiers locaux.",[10,12825,12826],{},[26,12827],{"id":12828},"prerequisites",[30,12830,12832],{"id":12831},"que-faut-il-remplir-avant-la-remise","Que faut-il remplir avant la remise ?",[35,12834,12835,12844],{},[38,12836,12837],{},[41,12838,12839,12841],{},[44,12840,10010],{},[44,12842,12843],{},"Comment la reconnaître",[54,12845,12846,12862,12870,12885],{},[41,12847,12848,12850],{},[59,12849,10020],{},[59,12851,12852,4004,12854,293,12856,12858,12859,12861],{},[19,12853,10025],{},[19,12855,10028],{},[19,12857,9986],{},". Un ",[19,12860,10034],{}," voit l’archive mais ne peut rien remettre.",[41,12863,12864,12867],{},[59,12865,12866],{},"Version enregistrée",[59,12868,12869],{},"Pas de mention « Les modifications locales ne sont pas encore enregistrées ». PlanElec archive toujours la version enregistrée sur le serveur.",[41,12871,12872,12875],{},[59,12873,12874],{},"Aucune correction en attente",[59,12876,12877,12878,293,12880,12882,12883,4014],{},"La carte du document indique ",[19,12879,4602],{},[19,12881,4605],{},", et non ",[19,12884,4587],{},[41,12886,12887,12890],{},[59,12888,12889],{},"Valeurs complètes",[59,12891,12892],{},"Le serveur n’archive jamais une version dont les valeurs sont masquées.",[10,12894,12895,12896,12898,12899,4014],{},"Parmi les corrections qui bloquent la remise, on trouve par exemple « Données de raccordement pas encore confirmées », « Placer les appareils manquants sur le plan de position », « Vérifier et confirmer le schéma unifilaire » ou « Compléter les désignations des circuits ». Tant qu’une correction reste ouverte, ",[19,12897,4598],{}," reste désactivé. Un brouillon reste possible. La préparation des documents est décrite dans ",[26,12900,4615],{"href":4614},[10,12902,12903],{},[26,12904],{"id":6007},[30,12906,12908],{"id":12907},"comment-créer-une-version-de-remise","Comment créer une version de remise ?",[261,12910,12911,12917,12923,12932,12945],{},[152,12912,12913,12914,12916],{},"Ouvrez l’espace ",[19,12915,3930],{}," du studio et enregistrez le projet.",[152,12918,12919,12920,12922],{},"Contrôlez le document avec ",[19,12921,4574],{}," et choisissez, si proposé, le format et les options.",[152,12924,4017,12925,12927,12928,5943,12930,4014],{},[19,12926,4598],{}," sur la carte du document. Pour le dossier, le même bouton se trouve dans le panneau latéral ",[19,12929,5814],{},[19,12931,4580],{},[152,12933,12934,12935,12938,12939,12941,12942,12944],{},"Si le document comporte des remarques, la fenêtre ",[19,12936,12937],{},"Confirmer les remarques pour cette version"," s’ouvre. Lisez la liste. ",[19,12940,6021],{}," poursuit, ",[19,12943,4893],{}," interrompt.",[152,12946,12947,12948,4014],{},"PlanElec génère le PDF, l’archive et télécharge le fichier archivé. L’étape a réussi lorsque le message « La version d'archive … a été créée et téléchargée. » apparaît et que la nouvelle version figure dans l’",[19,12949,12950],{},"Archive documentaire",[10,12952,12953,12954,12956],{},"Les remarques confirmées restent dans les preuves de remise archivées. La confirmation vaut uniquement pour la révision actuelle et la sortie sélectionnée. La ",[19,12955,5565],{}," comporte toujours une telle remarque : elle contient les quantités du modèle et ne constitue pas une liste de commande approuvée.",[10,12958,12959,12960,12962],{},"Si l’auto-contrôle est désactivé dans le projet, la fenêtre regroupe les constats sur une seule ligne, par exemple « 3 constats non évalués (auto-contrôle désactivé) ». Le ",[19,12961,5537],{}," ne peut alors pas être remis.",[10,12964,12965],{},"Si vous modifiez le projet ou la sélection d’export pendant la préparation, PlanElec interrompt l’opération. Relancez ensuite l’export : chaque version d’archive correspond ainsi à un état enregistré du projet.",[10,12967,12968],{},[26,12969],{"id":12970},"sealing",[30,12972,12974],{"id":12973},"que-devient-le-pdf-lors-de-larchivage","Que devient le PDF lors de l’archivage ?",[149,12976,12977,12983,12989,12995],{},[152,12978,12979,12982],{},[19,12980,12981],{},"Identifiant propre :"," le serveur attribue un UUID aléatoire et conserve le fichier dans un stockage privé du projet. Il n’est accessible qu’avec un accès au projet ou avec la clé d’accès contenue dans le code QR.",[152,12984,12985,12988],{},[19,12986,12987],{},"Code QR sur chaque page :"," en bas à droite de chaque page figure un code QR dans un cadre blanc, accompagné de « PlanElec » et des huit premiers caractères de l’identifiant.",[152,12990,12991,12994],{},[19,12992,12993],{},"Empreinte SHA-256 :"," après l’ajout des codes QR, le serveur calcule l’empreinte SHA-256 du fichier final et l’enregistre. Le fichier téléchargé est exactement ce fichier.",[152,12996,12997,13000],{},[19,12998,12999],{},"Aucun contenu actif :"," champs de formulaire, annotations, liens et actions automatiques sont retirés du PDF.",[10,13002,13003,13004,4014],{},"L’archive accepte des PDF jusqu’à 20 Mo et 200 pages. Une version archivée ne change plus. Après une modification du projet, vous créez une nouvelle version ; l’ancienne reste conservée comme ",[19,13005,13006],{},"Remplacée",[10,13008,13009],{},[26,13010],{"id":864},[30,13012,13014],{"id":13013},"où-trouver-lhistorique-des-versions","Où trouver l’historique des versions ?",[10,13016,13017,13018,13020,13021,13023,13024,13026,13027,13030],{},"Sous les documents de l’espace ",[19,13019,3930],{}," se trouve la section ",[19,13022,12950],{},", intitulée ",[19,13025,6025],{},". Chaque ligne indique le type de document, le numéro de version (par exemple v2), le statut, la date, le nombre de pages et les douze premiers caractères de l’empreinte. ",[19,13028,13029],{},"Actualiser"," recharge la liste.",[35,13032,13033,13041],{},[38,13034,13035],{},[41,13036,13037,13039],{},[44,13038,4800],{},[44,13040,405],{},[54,13042,13043,13053,13062,13072,13082],{},[41,13044,13045,13050],{},[59,13046,13047],{},[19,13048,13049],{},"Actuelle",[59,13051,13052],{},"Version la plus récente de ce type de document dans le projet",[41,13054,13055,13059],{},[59,13056,13057],{},[19,13058,13006],{},[59,13060,13061],{},"Une version plus récente du même type existe ; le fichier reste accessible",[41,13063,13064,13069],{},[59,13065,13066],{},[19,13067,13068],{},"Révoquée",[59,13070,13071],{},"L’accès public par QR est désactivé",[41,13073,13074,13079],{},[59,13075,13076],{},[19,13077,13078],{},"Version de remise",[59,13080,13081],{},"Créée avec une preuve de remise enregistrée (révision, remarques confirmées)",[41,13083,13084,13089],{},[59,13085,13086],{},[19,13087,13088],{},"Archive existante sans preuve de remise",[59,13090,13091],{},"Version d’archive antérieure à la preuve de remise",[10,13093,13094,13095,4004,13097,120,13099,13101],{},"Chaque ligne propose ",[19,13096,6028],{},[19,13098,6031],{},[19,13100,6034],{},". Tous les membres du projet, lecteurs compris, peuvent télécharger ces fichiers.",[10,13103,13104],{},[26,13105],{"id":13106},"sticker",[30,13108,13110],{"id":13109},"comment-imprimer-létiquette-qr","Comment imprimer l’étiquette QR ?",[261,13112,13113,13118,13126],{},[152,13114,5811,13115,13117],{},[19,13116,12950],{},", choisissez la version voulue.",[152,13119,4017,13120,13122,13123,13125],{},[19,13121,6031],{}," pour une étiquette de 40 × 40 mm avec « PlanElec.be », le code QR, le numéro de version et l’identifiant court. ",[19,13124,6034],{}," fournit uniquement le code QR en image de 472 × 472 pixels, soit 40 mm à 300 dpi.",[152,13127,13128],{},"Imprimez l’étiquette en taille réelle et scannez-la une fois pour contrôle avant de la coller.",[10,13130,13131],{},"L’étiquette renvoie exactement à cette version d’archive. Après une nouvelle remise, imprimez donc aussi une nouvelle étiquette. Pour une version révoquée, PlanElec ne fournit plus d’étiquette.",[10,13133,13134],{},[26,13135],{"id":13136},"verify",[30,13138,13140],{"id":13139},"que-montre-la-page-de-vérification-après-le-scan","Que montre la page de vérification après le scan ?",[10,13142,13143,13144,13146,13147,13150],{},"Le code QR ouvre la page ",[19,13145,12687],{}," à l’adresse ",[14,13148,13149],{},"planelec.be\u002Fverify\u002F\u003Cidentifiant>",". Elle est accessible sans connexion et n’est pas indexée par les moteurs de recherche.",[35,13152,13153,13161],{},[38,13154,13155],{},[41,13156,13157,13159],{},[44,13158,11841],{},[44,13160,9196],{},[54,13162,13163,13182,13190,13198,13206],{},[41,13164,13165,13167],{},[59,13166,402],{},[59,13168,13169,4004,13172,13175,13176,293,13179],{},[19,13170,13171],{},"Version d'archive actuelle",[19,13173,13174],{},"Remplacée par une version plus récente"," (avec le numéro de la version récente), ",[19,13177,13178],{},"Accès public révoqué",[19,13180,13181],{},"Document supprimé",[41,13183,13184,13187],{},[59,13185,13186],{},"Type",[59,13188,13189],{},"Type de document, par exemple schéma unifilaire",[41,13191,13192,13195],{},[59,13193,13194],{},"Version, pages, date",[59,13196,13197],{},"Numéro de version, nombre de pages et date d’archivage",[41,13199,13200,13203],{},[59,13201,13202],{},"SHA-256",[59,13204,13205],{},"Empreinte complète du fichier archivé",[41,13207,13208,13211],{},[59,13209,13210],{},"ID du document",[59,13212,13213],{},"UUID complet",[10,13215,13216,13217,13220,13221,13224],{},"Le nom du projet, le client et l’adresse n’apparaissent pas sur la page de vérification. Le contenu s’ouvre avec ",[19,13218,13219],{},"Ouvrir le PDF archivé",". Cela ne fonctionne que si le lien du code QR est complet : il contient une clé d’accès après ",[14,13222,13223],{},"#access=",". La page retire cette clé de la barre d’adresse après le chargement. Si elle manque, la page indique « Ce lien ne contient aucune autorisation d'accès. Scannez à nouveau le code QR complet. » Avant de livrer le fichier, le serveur compare l’empreinte du fichier stocké à celle de l’archive et ne livre rien en cas d’écart.",[10,13226,13227],{},"Toute personne qui dispose du code QR peut ouvrir le PDF. Traitez donc les impressions et les étiquettes comme le document lui-même.",[10,13229,13230],{},[26,13231],{"id":13232},"hash",[30,13234,13236],{"id":13235},"comment-vérifier-vous-même-un-pdf-par-son-empreinte","Comment vérifier vous-même un PDF par son empreinte ?",[10,13238,13239],{},"Calculez l’empreinte SHA-256 du fichier reçu et comparez-la à la valeur affichée sur la page de vérification :",[149,13241,13242,13248,13254],{},[152,13243,13244,13245],{},"macOS : ",[14,13246,13247],{},"shasum -a 256 fichier.pdf",[152,13249,13250,13251],{},"Windows (PowerShell) : ",[14,13252,13253],{},"Get-FileHash fichier.pdf -Algorithm SHA256",[152,13255,13256,13257],{},"Linux : ",[14,13258,13259],{},"sha256sum fichier.pdf",[10,13261,13262],{},"Si les deux valeurs sont identiques, le fichier correspond exactement à la version d’archive. Le nom du fichier n’a aucune importance. La valeur change dès que le PDF a été réenregistré, signé après coup, annoté ou numérisé. Une impression ne se vérifie pas par empreinte : utilisez le code QR et ouvrez le PDF archivé.",[10,13264,13265],{},[26,13266],{"id":13267},"revoke",[30,13269,13271],{"id":13270},"comment-révoquer-laccès-par-qr","Comment révoquer l’accès par QR ?",[261,13273,13274,13288,13297],{},[152,13275,5811,13276,13278,13279,13281,13282,13284,13285,13287],{},[19,13277,12950],{},", repérez la version concernée et cliquez sur ",[19,13280,6037],{},". Seuls le ",[19,13283,10025],{}," et un ",[19,13286,10028],{}," voient ce bouton.",[152,13289,13290,13291,132,13294,4014],{},"Confirmez dans la fenêtre ",[19,13292,13293],{},"Révoquer l'accès public par QR ?",[19,13295,13296],{},"Révoquer l'accès",[152,13298,13299,13300,13302],{},"La ligne affiche ensuite ",[19,13301,13068],{}," et le message « L'accès public par QR a été révoqué. » apparaît.",[10,13304,13305,13306,13308,13309,13312],{},"Les codes QR imprimés de cette version n’ouvrent plus le PDF ; la page de vérification indique ",[19,13307,13178],{},". Les membres du projet conservent leur accès via l’archive. ",[19,13310,13311],{},"Cette révocation est irréversible."," Pour obtenir de nouveau un code QR valide, créez une nouvelle version de remise.",[10,13314,13315],{},[26,13316],{"id":543},[30,13318,13320],{"id":13319},"que-confirme-la-vérification-et-que-ne-confirme-t-elle-pas","Que confirme la vérification, et que ne confirme-t-elle pas ?",[35,13322,13323,13333],{},[38,13324,13325],{},[41,13326,13327,13330],{},[44,13328,13329],{},"La page de vérification confirme",[44,13331,13332],{},"La page de vérification ne confirme pas",[54,13334,13335,13343,13351,13359],{},[41,13336,13337,13340],{},[59,13338,13339],{},"Le fichier a été archivé sous cet identifiant dans un projet PlanElec",[59,13341,13342],{},"Que l’installation est conforme au RGIE ou a passé un contrôle",[41,13344,13345,13348],{},[59,13346,13347],{},"Le fichier stocké a exactement l’empreinte SHA-256 affichée",[59,13349,13350],{},"Une déclaration de conformité ou l’avis d’un organisme agréé",[41,13352,13353,13356],{},[59,13354,13355],{},"Si cette version est actuelle, remplacée, révoquée ou supprimée",[59,13357,13358],{},"Une signature électronique ou l’identité d’un signataire",[41,13360,13361,13364],{},[59,13362,13363],{},"La date d’archivage de la version et son nombre de pages",[59,13365,13366],{},"Que la conception est techniquement correcte ou exécutée ainsi sur chantier",[10,13368,13369,13370,13372,13373,13376],{},"Même archivé, le ",[19,13371,5537],{}," reste un autocontrôle logiciel des règles prises en charge. Son périmètre est décrit dans ",[26,13374,13375],{"href":4520},"Ce que vérifie l’autocontrôle",". L’évaluation officielle de l’installation relève d’un organisme agréé.",[10,13378,13379],{},[26,13380],{"id":13381},"messages",[30,13383,13385],{"id":13384},"quels-messages-peuvent-apparaître-lors-de-larchivage","Quels messages peuvent apparaître lors de l’archivage ?",[35,13387,13388,13397],{},[38,13389,13390],{},[41,13391,13392,13394],{},[44,13393,12112],{},[44,13395,13396],{},"Que faire",[54,13398,13399,13407,13415,13423,13431],{},[41,13400,13401,13404],{},[59,13402,13403],{},"« Cette sortie nécessite encore des corrections. »",[59,13405,13406],{},"Résoudre les corrections ouvertes sur la carte du document",[41,13408,13409,13412],{},[59,13410,13411],{},"« Le projet n’a pas encore été entièrement enregistré. … »",[59,13413,13414],{},"Résoudre l’erreur d’enregistrement, puis relancer l’export",[41,13416,13417,13420],{},[59,13418,13419],{},"« Le projet ou la sélection d’export a changé pendant la préparation. … »",[59,13421,13422],{},"Relancer l’export sans modifier le projet entre-temps",[41,13424,13425,13428],{},[59,13426,13427],{},"« Cette version est incomplète et ne peut pas être archivée. … »",[59,13429,13430],{},"Les valeurs sont masquées ; cette version reste un brouillon",[41,13432,13433,13436],{},[59,13434,13435],{},"« L’archive n’a pas pu être chargée. Veuillez réessayer. »",[59,13437,13438,13439,13441],{},"Cliquer sur ",[19,13440,13029],{}," dans l’archive documentaire",[10,13443,13444,13445,13447,13448,4014],{},"Retour à ",[26,13446,4615],{"href":4614}," ou à la ",[26,13449,5425],{"href":5424},{"title":822,"searchDepth":823,"depth":823,"links":13451},[13452,13453,13454,13455,13456,13457,13458,13459,13460,13461,13462],{"id":12696,"depth":823,"text":12697},{"id":12831,"depth":823,"text":12832},{"id":12907,"depth":823,"text":12908},{"id":12973,"depth":823,"text":12974},{"id":13013,"depth":823,"text":13014},{"id":13109,"depth":823,"text":13110},{"id":13139,"depth":823,"text":13140},{"id":13235,"depth":823,"text":13236},{"id":13270,"depth":823,"text":13271},{"id":13319,"depth":823,"text":13320},{"id":13384,"depth":823,"text":13385},"Dans Export, vous créez une version de remise : PlanElec archive le PDF sans modification avec un identifiant, un code QR et une empreinte SHA-256. La page de vérification confirme l’origine et l’intégrité du fichier, pas un contrôle RGIE ni une signature.","document-archive-verification","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fdocument-archive-verification.webp",{},15,"\u002Fhelp\u002Fdocument-archive-verification.fr",{"title":4610,"description":13463},"Archiver des documents versionnés et les vérifier par QR","archiver-et-verifier-les-documents","help\u002Fdocument-archive-verification.fr",[13474,13475,13476,13202,13477,13478],"archive documentaire","version de remise","code QR","versions","vérification","cK4IjkqJtl5vpieOHL3ZJ6FiVOkgfuMpnFnMsnGtYno",{"id":13481,"title":13482,"body":13483,"category":844,"description":14910,"extension":846,"guideId":14911,"image":14912,"locale":849,"meta":14913,"navigation":851,"order":14914,"path":14915,"publishedAt":6105,"readTime":7765,"seo":14916,"seoTitle":857,"slug":14917,"stem":14918,"tags":14919,"updatedAt":14923,"__hash__":14924},"help\u002Fhelp\u002Ftroubleshooting.fr.md","Résoudre les problèmes courants dans PlanElec",{"type":7,"value":13484,"toc":14895},[13485,13488,13492,13677,13682,13686,13698,13701,13749,13766,13769,13774,13778,13786,13804,13865,13872,13877,13881,13887,13910,13913,13916,13927,13934,13939,13943,13966,14014,14017,14042,14045,14137,14146,14157,14164,14169,14173,14179,14254,14257,14260,14298,14304,14309,14313,14316,14350,14396,14405,14410,14414,14420,14470,14473,14504,14507,14526,14533,14538,14542,14548,14570,14576,14581,14585,14588,14700,14705,14710,14714,14717,14785,14795,14805,14810,14814,14817,14860,14878,14882],[10,13486,13487],{},"Presque chaque blocage dans PlanElec indique lui-même sa cause : une échelle pas encore confirmée, un appareil sans circuit, un point ouvert avant la version de remise, un tracé de câble incomplet, un module sans emplacement sur une rangée, un état de synchronisation, une limite IA atteinte ou un navigateur sans WebGL. Cette page relie chaque message à sa cause dans le logiciel et vous guide pas à pas vers la solution. Il vous faut un projet ouvert dans le studio. Lorsqu’un message disparaît, PlanElec ne voit plus le point dans les données saisies. Le contrôle technique de l’installation et le contrôle de conformité par l’organisme agréé restent distincts.",[30,13489,13491],{"id":13490},"quel-problème-rencontrez-vous","Quel problème rencontrez-vous ?",[35,13493,13494,13504],{},[38,13495,13496],{},[41,13497,13498,13500,13502],{},[44,13499,10301],{},[44,13501,12115],{},[44,13503,10298],{},[54,13505,13506,13522,13536,13550,13568,13582,13596,13613,13630,13644,13658],{},[41,13507,13508,13513,13516],{},[59,13509,13510,13511],{},"« Sans échelle confirmée, la reprise reste bloquée. » ou statut ",[19,13512,10287],{},[59,13514,13515],{},"Échelle du plan reconnu manquante ou non confirmée",[59,13517,13518],{},[26,13519,13521],{"href":13520},"#floorplan-scale","Reprendre le plan",[41,13523,13524,13527,13530],{},[59,13525,13526],{},"« Le plan compte … pages. Choisissez dans l’aperçu celle qui porte le plan. »",[59,13528,13529],{},"PDF de plusieurs pages",[59,13531,13532],{},[26,13533,13535],{"href":13534},"#floorplan-pages","PDF et format de fichier",[41,13537,13538,13541,13544],{},[59,13539,13540],{},"Appareil absent du schéma unifilaire, « … appareils sans circuit »",[59,13542,13543],{},"L’appareil n’est relié à aucun dispositif de protection",[59,13545,13546],{},[26,13547,13549],{"href":13548},"#device-without-circuit","Appareil sans circuit",[41,13551,13552,13559,13562],{},[59,13553,13554,13556,13557],{},[19,13555,4598],{}," est bloqué, statut ",[19,13558,4587],{},[59,13560,13561],{},"Au moins un point ouvert pour ce document",[59,13563,13564],{},[26,13565,13567],{"href":13566},"#export-blocked","Export bloqué",[41,13569,13570,13573,13576],{},[59,13571,13572],{},"« L'auto-contrôle est désactivé » sur le rapport d’auto-contrôle",[59,13574,13575],{},"Auto-contrôle désactivé pour le projet",[59,13577,13578],{},[26,13579,13581],{"href":13580},"#self-check-off","Auto-contrôle désactivé",[41,13583,13584,13587,13590],{},[59,13585,13586],{},"Marque « ! » rouge ou jaune sur un symbole, point orange sur un appareil",[59,13588,13589],{},"Constat de l’auto-contrôle, liaison manquante ou couleur du circuit",[59,13591,13592],{},[26,13593,13595],{"href":13594},"#colour-markers","Marquages de couleur",[41,13597,13598,13604,13607],{},[59,13599,13600,13603],{},[19,13601,13602],{},"Tracé incomplet"," ou « longueur manquante pour le calcul exact de ΔU »",[59,13605,13606],{},"Tracé non continu, aucune longueur saisie",[59,13608,13609],{},[26,13610,13612],{"href":13611},"#cable-length","Longueur de câble",[41,13614,13615,13621,13624],{},[59,13616,13617,13620],{},[19,13618,13619],{},"Modules non placés"," dans le tableau",[59,13622,13623],{},"Le module existe mais n’a pas d’emplacement sur un rail DIN",[59,13625,13626],{},[26,13627,13629],{"href":13628},"#cabinet-unplaced","Placer les modules",[41,13631,13632,13635,13638],{},[59,13633,13634],{},"« Non prêt : Synchronisation en direct désactivée », « Conflit », « réservé dans une autre session »",[59,13636,13637],{},"État d’enregistrement et de synchronisation",[59,13639,13640],{},[26,13641,13643],{"href":13642},"#sync","Enregistrement et synchronisation",[41,13645,13646,13649,13652],{},[59,13647,13648],{},"« Le quota journalier de reconnaissances est épuisé. » ou quota IA insuffisant",[59,13650,13651],{},"Limite journalière de reconnaissance ou quota IA épuisé",[59,13653,13654],{},[26,13655,13657],{"href":13656},"#ai-limit","Limite IA",[41,13659,13660,13668,13671],{},[59,13661,13662,293,13665],{},[19,13663,13664],{},"Vue 3D indisponible",[19,13666,13667],{},"Affichage interrompu",[59,13669,13670],{},"Pas de WebGL ou connexion graphique réinitialisée",[59,13672,13673],{},[26,13674,13676],{"href":13675},"#fallback-3d","Message 3D",[10,13678,13679],{},[26,13680],{"id":13681},"floorplan-scale",[30,13683,13685],{"id":13684},"pourquoi-le-plan-reconnu-ne-peut-il-pas-être-repris","Pourquoi le plan reconnu ne peut-il pas être repris ?",[10,13687,13688,13689,13691,13692,13694,13695,13697],{},"La reconnaissance de plan par IA ne reprend les murs et les pièces qu’une fois l’échelle confirmée. S’il manque une information, l’analyse affiche ",[19,13690,10287],{}," avec le message « Une information manque encore pour la reprise, généralement l’échelle. Vérifiez et complétez. » La section ",[19,13693,7413],{}," du panneau ",[19,13696,7572],{}," indique alors : « Sans échelle confirmée, la reprise reste bloquée. »",[10,13699,13700],{},"Pour débloquer la reprise :",[261,13702,13703,13719,13730,13738,13744],{},[152,13704,13705,13706,13708,13709,13711,13712,4004,13714,293,13716,13718],{},"Ouvrez dans le studio le panneau ",[19,13707,7572],{},". La section ",[19,13710,7413],{}," indique l’origine de l’échelle, par exemple ",[19,13713,10444],{},[19,13715,10454],{},[19,13717,10464],{},", ainsi que les repères utilisés en mètres.",[152,13720,13721,13722,13724,13725,13727,13728,4014],{},"Si l’échelle manque ou si PlanElec signale « Les surfaces imprimées sur le plan ne correspondent pas à l'échelle. Mesurez une longueur connue. », ouvrez ",[19,13723,10137],{}," et choisissez ",[19,13726,10532],{},". Marquez deux points d’une distance connue, saisissez sa longueur en mètres et choisissez ",[19,13729,10593],{},[152,13731,13732,13733,13735,13736,4014],{},"Vérifiez une deuxième longueur connue sur le plan. Si elle correspond, choisissez ",[19,13734,7586],{},". Critère de réussite : la section affiche ",[19,13737,10492],{},[152,13739,13740,13741,13743],{},"Choisissez le ",[19,13742,10056],{}," en bas du panneau. « Le niveau cible doit être vide. » S’il ne l’est pas, PlanElec indique « Le niveau cible n’est pas vide. » Créez alors un étage vide ou choisissez-en un autre.",[152,13745,5031,13746,13748],{},[19,13747,9784],{},". La reprise s’annule en une seule étape.",[10,13750,13751,13752,13754,13755,13757,13758,13760,13761,120,13764,4014],{},"Si vous travaillez sans IA avec un plan importé comme calque, l’atelier du calque affiche à l’étape ",[19,13753,7413],{}," « Pas encore d’échelle » tant que vous n’avez pas étalonné. Choisissez-y deux points d’une distance connue, ou ",[19,13756,7444],{}," dans la barre d’outils, puis terminez avec ",[19,13759,7426],{},". Détails : ",[26,13762,119],{"href":13763},"\u002Ffr\u002Fhelp\u002Fimporter-et-etalonner-un-plan#calibrate",[26,13765,11630],{"href":123},[10,13767,13768],{},"La reconnaissance fournit une proposition. Vérifiez vous-même les cotes, le tracé des murs et les limites des pièces sur le plan d’origine avant la planification électrique.",[10,13770,13771],{},[26,13772],{"id":13773},"floorplan-pages",[30,13775,13777],{"id":13776},"que-faire-si-le-pdf-compte-plusieurs-pages-ou-nest-pas-reconnu","Que faire si le PDF compte plusieurs pages ou n’est pas reconnu ?",[10,13779,13780,13781,13783,13784,4555],{},"Si vous démarrez sur un étage vide avec ",[19,13782,4346],{},", PlanElec enregistre le fichier dans le dossier de documents du projet. Pour un PDF de plusieurs pages, PlanElec ne choisit pas de page au hasard. Vous voyez « Le plan compte {nombre} pages. Choisissez dans l’aperçu celle qui porte le plan. » et l’",[19,13785,10128],{},[261,13787,13788,13793,13798],{},[152,13789,5811,13790,13792],{},[19,13791,10128],{},", allez à la page qui porte le plan.",[152,13794,5031,13795,13797],{},[19,13796,7546],{},". La reconnaissance porte uniquement sur cette page.",[152,13799,13800,13801,13803],{},"Vérifiez le résultat dans le panneau ",[19,13802,7572],{}," comme décrit ci-dessus.",[35,13805,13806,13817],{},[38,13807,13808],{},[41,13809,13810,13812,13814],{},[44,13811,12112],{},[44,13813,12115],{},[44,13815,13816],{},"Solution",[54,13818,13819,13833,13844,13854],{},[41,13820,13821,13824,13827],{},[59,13822,13823],{},"« Ce fichier ne peut pas être reconnu. Formats possibles : PDF, PNG, JPEG et WebP jusqu’à 50 Mo. »",[59,13825,13826],{},"Autre format, p. ex. DXF, ou fichier trop lourd",[59,13828,13829,13830,13832],{},"Importer le DXF via ",[19,13831,4338],{}," comme calque ; réduire l’image ou le PDF",[41,13834,13835,13838,13841],{},[59,13836,13837],{},"« La reconnaissance automatique n’a pas trouvé de plan exploitable. … »",[59,13839,13840],{},"Aucune proposition exploitable",[59,13842,13843],{},"Le plan est prêt comme calque : l’ajuster et redessiner les murs extérieurs",[41,13845,13846,13849,13852],{},[59,13847,13848],{},"« La reconnaissance a pris trop de temps et a été interrompue. … »",[59,13850,13851],{},"Limite de durée de l’analyse",[59,13853,10692],{},[41,13855,13856,13859,13862],{},[59,13857,13858],{},"« La reconnaissance n’est pas encore disponible — le fichier reste utilisable comme pièce du projet »",[59,13860,13861],{},"Fonction non accessible pour votre compte ou votre rôle",[59,13863,13864],{},"Redessiner le fichier comme calque",[10,13866,13867,13868,4014],{},"Pour les plans d’architecte qui portent plusieurs niveaux sur une même feuille, marquez une zone par plan lors de l’import : ",[26,13869,13871],{"href":13870},"\u002Ffr\u002Fhelp\u002Fimporter-et-etalonner-un-plan#sections","Séparer plusieurs plans sur une même feuille",[10,13873,13874],{},[26,13875],{"id":13876},"device-without-circuit",[30,13878,13880],{"id":13879},"pourquoi-un-appareil-napparaît-il-pas-dans-le-schéma-unifilaire","Pourquoi un appareil n’apparaît-il pas dans le schéma unifilaire ?",[10,13882,13883,13884,13886],{},"Le schéma unifilaire dessine chaque circuit à partir de son dispositif de protection, avec les récepteurs qui y sont raccordés. Un appareil placé sur le plan mais affecté à aucun circuit n’a pas ce chemin et n’apparaît donc pas encore. L’auto-contrôle le signale par « \"{nom}\" n'est pas raccordé », et la zone ",[19,13885,4458],{}," affiche la tâche « {nombre} appareils sans circuit ».",[261,13888,13889,13894,13900,13905],{},[152,13890,8736,13891,13893],{},[19,13892,4458],{},". Sans sélection, le panneau latéral affiche les tâches ouvertes.",[152,13895,13896,13897,13899],{},"Pour les appareils sans circuit, choisissez ",[19,13898,8828],{},". L’aperçu de la planification automatique indique pour chaque appareil le circuit et la protection ; vous la reprenez de manière explicite.",[152,13901,13902,13903,4014],{},"Pour une affectation ciblée, sélectionnez l’appareil et utilisez ",[19,13904,8079],{},[152,13906,8736,13907,13909],{},[19,13908,569],{},". Critère de réussite : l’appareil figure sous son circuit.",[10,13911,13912],{},"Ne créez pas l’appareil une seconde fois pour le voir dans le schéma. Il reste le même objet dans le plan, l’installation et le schéma.",[10,13914,13915],{},"Deux messages proches :",[149,13917,13918,13924],{},[152,13919,13920,13921,13923],{},"« {nom} : tableau ouvert » signifie : raccordé électriquement, mais pas encore attribué à un tableau. ",[19,13922,8839],{}," ouvre l’aperçu. Dans l’export apparaît alors « Affectation au tableau encore à définir. Complétez l’installation. »",[152,13925,13926],{},"« Le consommateur {référence} n'est pas placé sur le plan de position » est le cas inverse : l’appareil existe électriquement mais n’a pas de symbole sur le plan de position. Pour l’export du plan de position, le message est « Placer les appareils manquants sur le plan de position ».",[10,13928,13929,13930,120,13932,4014],{},"Pour aller plus loin : ",[26,13931,8726],{"href":11504},[26,13933,4491],{"href":4490},[10,13935,13936],{},[26,13937],{"id":13938},"export-blocked",[30,13940,13942],{"id":13941},"pourquoi-créer-la-version-de-remise-est-il-bloqué","Pourquoi « Créer la version de remise » est-il bloqué ?",[10,13944,5432,13945,13947,13948,13950,13951,13953,13954,120,13957,13959,13960,293,13963,4014],{},[19,13946,3930],{},", chaque document dispose d’une carte avec un statut et deux possibilités : ",[19,13949,4580],{}," fournit à tout moment un PDF marqué comme brouillon, dès que le document a du contenu. ",[19,13952,4598],{}," ne devient actif que lorsqu’aucun blocage n’est ouvert pour ce document. L’en-tête résume cela sous ",[19,13955,13956],{},"Documents provisoires",[19,13958,5998],{},", avec ",[19,13961,13962],{},"Prêt à exporter",[19,13964,13965],{},"Pas encore prêt",[35,13967,13968,13976],{},[38,13969,13970],{},[41,13971,13972,13974],{},[44,13973,402],{},[44,13975,405],{},[54,13977,13978,13987,13996,14005],{},[41,13979,13980,13984],{},[59,13981,13982],{},[19,13983,5641],{},[59,13985,13986],{},"Le document n’a pas encore de contenu (« Ajouter le contenu de ce document »).",[41,13988,13989,13993],{},[59,13990,13991],{},[19,13992,4587],{},[59,13994,13995],{},"Au moins un blocage est ouvert. Seul le brouillon est possible.",[41,13997,13998,14002],{},[59,13999,14000],{},[19,14001,4605],{},[59,14003,14004],{},"Aucun blocage, mais des remarques. Vous les confirmez avant l’archivage.",[41,14006,14007,14011],{},[59,14008,14009],{},[19,14010,4602],{},[59,14012,14013],{},"Ni blocage ni remarque.",[10,14015,14016],{},"Pour trouver le blocage :",[261,14018,14019,14024,14027,14036],{},[152,14020,8736,14021,14023],{},[19,14022,3930],{},". Sous le statut de chaque carte, le premier point ouvert figure sous forme de lien.",[152,14025,14026],{},"Cliquez dessus. PlanElec ouvre la vue dans laquelle vous le corrigez.",[152,14028,14029,14030,14032,14033,14035],{},"Corrigez le point et revenez à ",[19,14031,3930],{},". Le blocage suivant apparaît, jusqu’à ce que ",[19,14034,4598],{}," soit actif.",[152,14037,14038,14039,14041],{},"S’il ne reste que des remarques, la fenêtre « Confirmer les remarques pour cette version » s’affiche. Avec ",[19,14040,6021],{},", elles font partie de la version de remise enregistrée.",[10,14043,14044],{},"Blocages fréquents dans un nouveau projet :",[35,14046,14047,14057],{},[38,14048,14049],{},[41,14050,14051,14054],{},[44,14052,14053],{},"Texte dans l’export",[44,14055,14056],{},"Où le corriger",[54,14058,14059,14072,14088,14101,14111,14121,14129],{},[41,14060,14061,14064],{},[59,14062,14063],{},"« Vérifier et confirmer le schéma unifilaire »",[59,14065,14066,4951,14068,14071],{},[19,14067,569],{},[19,14069,14070],{},"Marquer le schéma comme vérifié",". Toute modification ultérieure du schéma annule ce marquage.",[41,14073,14074,14077],{},[59,14075,14076],{},"« Données de raccordement pas encore confirmées »",[59,14078,14079,14081,14082,4951,14085],{},[19,14080,4458],{}," → « Le raccordement est une hypothèse » → ",[19,14083,14084],{},"Vérifier et confirmer",[19,14086,14087],{},"Confirmer les données de raccordement",[41,14089,14090,14093],{},[59,14091,14092],{},"« Compléter et confirmer les modes de pose », « Compléter le pouvoir de coupure »",[59,14094,14095,14097,14098],{},[19,14096,3930],{}," → section ",[19,14099,14100],{},"Compléter les informations manquantes",[41,14102,14103,14106],{},[59,14104,14105],{},"« Placer les appareils manquants sur le plan de position »",[59,14107,14108,14109],{},"Plan de position, voir ",[26,14110,13549],{"href":13548},[41,14112,14113,14116],{},[59,14114,14115],{},"« Placer les modules manquants sur les rails DIN »",[59,14117,14118,14119],{},"Tableau, voir ",[26,14120,13629],{"href":13628},[41,14122,14123,14126],{},[59,14124,14125],{},"« Compléter les désignations des circuits »",[59,14127,14128],{},"Donner une désignation à chaque circuit ; le lien mène au tableau",[41,14130,14131,14134],{},[59,14132,14133],{},"« Vérifier les liaisons incohérentes »",[59,14135,14136],{},"Schéma unifilaire : corriger les liaisons de l’élément indiqué",[10,14138,14139,14141,14142,14145],{},[19,14140,14070],{}," reste désactivé tant que des constats sont ouverts : « Corrigez les points signalés avant de marquer le schéma comme vérifié. » Le bouton ",[19,14143,14144],{},"Avertissements"," à côté mène au premier constat ouvert.",[10,14147,14148,14151,14152,5943,14154,4014],{},[19,14149,14150],{},"Erreurs et avertissements de l’auto-contrôle :"," une erreur, une donnée manquante ou une règle non évaluée bloque la version de remise. Un avertissement ne bloque pas ; il apparaît comme remarque à confirmer. Vous lisez les constats dans le panneau ",[19,14153,4516],{},[19,14155,14156],{},"Avertissements · Validation",[10,14158,14159,14160,120,14162,4014],{},"Si vous venez de modifier quelque chose, la carte indique « Les modifications locales ne sont pas encore enregistrées. Vous pouvez déjà télécharger un brouillon. » La version de remise suit dès que l’état est enregistré. Plus de détails : ",[26,14161,4615],{"href":4614},[26,14163,12525],{"href":4520},[10,14165,14166],{},[26,14167],{"id":14168},"colour-markers",[30,14170,14172],{"id":14171},"pourquoi-un-interrupteur-ou-une-lampe-est-il-marqué-en-orange","Pourquoi un interrupteur ou une lampe est-il marqué en orange ?",[10,14174,14175,14176,14178],{},"Dans PlanElec, l’orange a l’une de deux significations selon la vue : sur le plan, un appareil portant un point orange n’est pas encore lié à l’installation, et une ligne ou un symbole entièrement orange porte simplement la couleur de son circuit. Dans le ",[19,14177,569],{},", les constats de l’auto-contrôle ne colorent aucun symbole : ils apparaissent sous forme d’une petite marque dans le coin du symbole, un cercle rouge avec « ! » pour une erreur et un triangle jaune avec « ! » pour un avertissement.",[35,14180,14181,14191],{},[38,14182,14183],{},[41,14184,14185,14187,14189],{},[44,14186,10301],{},[44,14188,7692],{},[44,14190,405],{},[54,14192,14193,14205,14217,14229,14239],{},[41,14194,14195,14198,14202],{},[59,14196,14197],{},"Cercle rouge avec « ! » dans le coin d’un symbole",[59,14199,14200],{},[19,14201,569],{},[59,14203,14204],{},"L’auto-contrôle signale une erreur pour cet élément. Si un élément a les deux, la marque indique l’erreur.",[41,14206,14207,14210,14214],{},[59,14208,14209],{},"Triangle jaune avec « ! » dans le coin d’un symbole",[59,14211,14212],{},[19,14213,569],{},[59,14215,14216],{},"L’auto-contrôle signale un avertissement pour cet élément.",[41,14218,14219,14222,14226],{},[59,14220,14221],{},"Cadre qui pulse brièvement autour d’un symbole",[59,14223,14224],{},[19,14225,569],{},[59,14227,14228],{},"Un constat vient d’apparaître, ou vous l’avez cliqué dans la liste des constats. Le cadre disparaît après quelques secondes.",[41,14230,14231,14234,14236],{},[59,14232,14233],{},"Petit point orange en haut à droite d’un appareil",[59,14235,4073],{},[59,14237,14238],{},"L’appareil n’est encore lié à aucun élément de l’installation. Un point vert signifie : lié.",[41,14240,14241,14244,14247],{},[59,14242,14243],{},"Symbole d’appareil ou ligne entièrement orange",[59,14245,14246],{},"Plan, schéma unifilaire",[59,14248,14249,14250,14253],{},"Couleur du circuit ou, en mode de couleur ",[19,14251,14252],{},"Type de symbole",", du type de symbole. Ce n’est pas un constat.",[10,14255,14256],{},"Les remarques ne reçoivent aucune marque sur le symbole et figurent uniquement dans la liste des constats. C’est le cas de la recommandation de placer en amont d’un différentiel 30 mA un différentiel temporisé de type S (sélectivité) : il s’agit d’une bonne pratique selon l’IEC 60364-5-53, et non d’une exigence du RGIE pour les installations domestiques.",[10,14258,14259],{},"Pour trouver la raison :",[261,14261,14262,14268,14275,14280],{},[152,14263,14264,14265,14267],{},"Dans le ",[19,14266,569],{},", touchez ou cliquez la marque sur le symbole. La liste des constats s’ouvre avec tous les constats de cet élément, chacun avec son motif et une suggestion. La petite légende en haut à droite du schéma explique les marques.",[152,14269,14270,14271,5943,14273,4014],{},"Si vous cliquez un constat dans la liste des constats, le schéma unifilaire se place sur l’élément et le met brièvement en évidence. Vous lisez aussi tous les constats dans le panneau ",[19,14272,4516],{},[19,14274,14156],{},[152,14276,14277,14278,4014],{},"Un point orange sur le plan devient vert dès que l’appareil est lié à l’installation, par exemple en l’affectant à un circuit : voir ",[26,14279,13549],{"href":13548},[152,14281,14282,14283,14286,14287,120,14289,14291,14292,14294,14295,4014],{},"Vous basculez le ",[19,14284,14285],{},"Mode de couleur"," entre ",[19,14288,7954],{},[19,14290,14252],{}," dans la légende des symboles : sur le plan via ",[19,14293,7285],{}," dans la barre de gauche, dans le schéma unifilaire via le bouton ",[19,14296,14297],{},"Légende des symboles",[10,14299,14300,14301,14303],{},"Si l’auto-contrôle est désactivé pour le projet, le schéma unifilaire n’affiche aucune marque de contrôle : voir ",[26,14302,13581],{"href":13580},". La vue 3D et l’export PDF n’affichent aucune marque de contrôle.",[10,14305,14306],{},[26,14307],{"id":14308},"self-check-off",[30,14310,14312],{"id":14311},"quand-désactiver-lauto-contrôle-dun-projet","Quand désactiver l’auto-contrôle d’un projet ?",[10,14314,14315],{},"L’auto-contrôle RGIE peut être désactivé par projet. Cette option s’adresse aux professionnels qui documentent une installation existante non conforme comme situation de départ. Pour une nouvelle étude, il reste activé.",[261,14317,14318,14325,14331,14345],{},[152,14319,14320,14321,4951,14323,4014],{},"Ouvrez le menu du projet (logo en haut à gauche) → ",[19,14322,4104],{},[19,14324,4108],{},[152,14326,14327,14328,4014],{},"Désactivez ",[19,14329,14330],{},"Auto-contrôle RGIE",[152,14332,14333,14334,14337,14338,14341,14342,4014],{},"Dans la fenêtre « Désactiver l'auto-contrôle ? », choisissez sous ",[19,14335,14336],{},"Motif (facultatif)"," par exemple ",[19,14339,14340],{},"Documenter l'existant comme situation de départ",", puis confirmez avec ",[19,14343,14344],{},"Désactiver",[152,14346,14347,14348,4014],{},"Critère de réussite : le studio affiche la mention ",[19,14349,13581],{},[35,14351,14352,14362],{},[38,14353,14354],{},[41,14355,14356,14359],{},[44,14357,14358],{},"Ce qui change",[44,14360,14361],{},"Effet lorsque l’auto-contrôle est désactivé",[54,14363,14364,14372,14380,14388],{},[41,14365,14366,14369],{},[59,14367,14368],{},"Constats dans l’éditeur",[59,14370,14371],{},"« Le contrôle RGIE continue en arrière-plan. Les constats ne sont pas affichés et les exports ne portent aucune mention de contrôle. »",[41,14373,14374,14377],{},[59,14375,14376],{},"Rapport d’auto-contrôle",[59,14378,14379],{},"Bloqué : « L'auto-contrôle est désactivé » ou « Indisponible tant que l'auto-contrôle est désactivé. »",[41,14381,14382,14385],{},[59,14383,14384],{},"Constats de règles, de câbles et de raccordement",[59,14386,14387],{},"Deviennent des remarques ; la remise indique « {nombre} constats non évalués (auto-contrôle désactivé) »",[41,14389,14390,14393],{},[59,14391,14392],{},"Reste bloquant",[59,14394,14395],{},"Liaisons incohérentes, contenu manquant, appareils, tableaux et modules non placés, désignations de circuit manquantes, modules non représentables et la confirmation du schéma",[10,14397,14398,14399,120,14401,14404],{},"Via la mention ",[19,14400,13581],{},[19,14402,14403],{},"Activer l'auto-contrôle",", vous revenez à tout moment à l’état normal.",[10,14406,14407],{},[26,14408],{"id":14409},"cable-length",[30,14411,14413],{"id":14412},"pourquoi-une-longueur-de-câble-manque-t-elle-ou-tracé-incomplet-saffiche-t-il","Pourquoi une longueur de câble manque-t-elle ou « Tracé incomplet » s’affiche-t-il ?",[10,14415,14416,14417,14419],{},"PlanElec détermine la longueur d’un câble dans cet ordre : une longueur mesurée que vous saisissez a la priorité. Sinon, la longueur du tracé dessiné s’applique. Si le tracé n’est pas continu, PlanElec n’affiche pas de valeur estimée mais ",[19,14418,13602],{},". Sans longueur, l’auto-contrôle signale « Câble \"{libellé}\" — longueur manquante pour le calcul exact de ΔU ».",[35,14421,14422,14432],{},[38,14423,14424],{},[41,14425,14426,14428,14430],{},[44,14427,4800],{},[44,14429,12115],{},[44,14431,13816],{},[54,14433,14434,14447,14459],{},[41,14435,14436,14441,14444],{},[59,14437,14438],{},[19,14439,14440],{},"Pas encore tracé",[59,14442,14443],{},"Le câble n’a pas encore de tracé",[59,14445,14446],{},"Dessiner le tracé automatiquement ou manuellement",[41,14448,14449,14453,14456],{},[59,14450,14451],{},[19,14452,13602],{},[59,14454,14455],{},"Il manque un tronçon, souvent le passage entre deux étages",[59,14457,14458],{},"Compléter le tronçon ou la liaison verticale",[41,14460,14461,14464,14467],{},[59,14462,14463],{},"« Aucun connecteur ne possède d'arrêt aux deux étages. »",[59,14465,14466],{},"Aucun escalier, gaine ou montée ne relie les deux étages",[59,14468,14469],{},"Créer la liaison verticale, puis tracer",[10,14471,14472],{},"Compléter le tracé :",[261,14474,14475,14483,14489,14499],{},[152,14476,14477,14478,4951,14481,4014],{},"Sur le plan de position, ouvrez ",[19,14479,14480],{},"Liaisons et câbles",[19,14482,4475],{},[152,14484,5031,14485,14488],{},[19,14486,14487],{},"Router tout automatiquement"," pour l’étage actif, ou cliquez sur un câble pour modifier ses points intermédiaires.",[152,14490,14491,14492,14495,14496,4014],{},"Pour un câble entre étages, choisissez ",[19,14493,14494],{},"Choisir un escalier, une gaine ou une montée",", puis ",[19,14497,14498],{},"Tracer via le connecteur",[152,14500,14501,14502,4014],{},"Critère de réussite : la longueur en mètres remplace ",[19,14503,13602],{},[10,14505,14506],{},"Saisir une longueur mesurée, par exemple sur une installation existante :",[261,14508,14509,14512,14517],{},[152,14510,14511],{},"Sélectionnez le câble dans le tracé de câble ou dans le schéma unifilaire.",[152,14513,8736,14514,4014],{},[19,14515,14516],{},"Modifier le câble et ses conducteurs",[152,14518,14519,14520,13724,14523,4014],{},"Indiquez la ",[19,14521,14522],{},"Longueur mesurée (m)",[19,14524,14525],{},"Enregistrer le câble",[10,14527,14528,14529,4014],{},"La longueur mesurée alimente la liste des câbles et le calcul de chute de tension ; la valeur géométrique du tracé reste conservée pour comparaison. Pour aller plus loin : ",[26,14530,14532],{"href":14531},"\u002Ffr\u002Fhelp\u002Fcommandes-circuits-et-chemins-de-cables#cable-routes","Planifier et retoucher un chemin de câble",[10,14534,14535],{},[26,14536],{"id":14537},"cabinet-unplaced",[30,14539,14541],{"id":14540},"pourquoi-des-modules-figurent-ils-sous-modules-non-placés","Pourquoi des modules figurent-ils sous « Modules non placés » ?",[10,14543,14544,14545,14547],{},"Un module qui existe dans le projet mais n’occupe encore aucun rail DIN apparaît en haut du tableau sous ",[19,14546,13619],{},", avec la mention « Présents dans le schéma, mais pas encore affectés à une rangée DIN. » C’est le cas par exemple lorsqu’une protection est créée dans le schéma unifilaire ou dans l’installation. Si vous la sélectionnez dans une autre vue, PlanElec indique : « Ce module n’est pas encore placé. Retrouvez-le dans la liste des modules non placés. »",[261,14549,14550,14555,14564,14567],{},[152,14551,8736,14552,14554],{},[19,14553,4480],{}," pour le tableau concerné.",[152,14556,11828,14557,14559,14560,14563],{},[19,14558,13619],{},", cliquez sur le module (",[19,14561,14562],{},"Placer","). PlanElec le pose sur le prochain emplacement libre.",[152,14565,14566],{},"Si PlanElec indique « Aucun emplacement libre dans le tableau attribué. », libérez d’abord de la place sur les rangées ou vérifiez le dimensionnement du coffret.",[152,14568,14569],{},"Critère de réussite : la barre disparaît dès qu’il ne reste plus de module à placer.",[10,14571,14572,14573,4014],{},"Pour le PDF du tableau, un module non placé est un blocage : « Placer les modules manquants sur les rails DIN ». Pour aller plus loin : ",[26,14574,14575],{"href":11517},"Concrétiser modules et coffret",[10,14577,14578],{},[26,14579],{"id":14580},"sync",[30,14582,14584],{"id":14583},"que-signifient-les-messages-denregistrement-et-de-synchronisation","Que signifient les messages d’enregistrement et de synchronisation ?",[10,14586,14587],{},"L’état d’enregistrement s’affiche sur le symbole rond de la barre d’état en bas à droite. Un clic ouvre le détail : état d’enregistrement, disponibilité hors ligne et connexion.",[35,14589,14590,14600],{},[38,14591,14592],{},[41,14593,14594,14596,14598],{},[44,14595,12112],{},[44,14597,405],{},[44,14599,13396],{},[54,14601,14602,14615,14630,14641,14660,14671,14685],{},[41,14603,14604,14607,14610],{},[59,14605,14606],{},"« Non prêt : Synchronisation en direct désactivée »",[59,14608,14609],{},"La préparation hors ligne nécessite la synchronisation en direct. L’enregistrement normal sur le serveur continue.",[59,14611,14612,14613,10111],{},"Rien. Vérifiez que ",[19,14614,4811],{},[41,14616,14617,14622,14625],{},[59,14618,14619,14621],{},[19,14620,4841],{},", « Enregistré dans ce navigateur. La sauvegarde sur le serveur est encore en attente. »",[59,14623,14624],{},"Les modifications sont dans le navigateur, pas encore sur le serveur.",[59,14626,14627,14628,4014],{},"Vérifier la connexion ; garder l’onglet ouvert jusqu’à ",[19,14629,4811],{},[41,14631,14632,14635,14638],{},[59,14633,14634],{},"« Un objet modifié est actuellement réservé dans une autre session. … »",[59,14636,14637],{},"Quelqu’un modifie le même objet dans une autre session.",[59,14639,14640],{},"Rien. Vos modifications sont conservées localement ; l’enregistrement est réessayé automatiquement.",[41,14642,14643,14648,14651],{},[59,14644,14645],{},[19,14646,14647],{},"Les modifications n’ont pas pu être fusionnées",[59,14649,14650],{},"Vos modifications contredisent la version partagée enregistrée.",[59,14652,14653,14495,14656,14659],{},[19,14654,14655],{},"Télécharger la sauvegarde locale",[19,14657,14658],{},"Charger la version du serveur"," et confirmer.",[41,14661,14662,14665,14668],{},[59,14663,14664],{},"« Conflit : ce projet a été modifié ailleurs. Veuillez recharger. »",[59,14666,14667],{},"Le projet a été enregistré ailleurs.",[59,14669,14670],{},"Recharger la page et vérifier votre dernière modification.",[41,14672,14673,14679,14682],{},[59,14674,14675,14678],{},[19,14676,14677],{},"Rechargement requis"," : « Cette page utilise une version antérieure. … »",[59,14680,14681],{},"Une nouvelle version de l’application est active.",[59,14683,14684],{},"Recharger la page ; vos modifications sont enregistrées localement.",[41,14686,14687,14692,14695],{},[59,14688,14689],{},[19,14690,14691],{},"Session expirée",[59,14693,14694],{},"Votre connexion a expiré.",[59,14696,14697,4014],{},[19,14698,14699],{},"Se reconnecter",[10,14701,14702,14704],{},[19,14703,14658],{}," remplace les modifications locales de cette session par le projet enregistré. Téléchargez donc d’abord la sauvegarde si vous souhaitez les conserver. Les autres onglets conservent leurs modifications locales.",[10,14706,14707],{},[26,14708],{"id":14709},"ai-limit",[30,14711,14713],{"id":14712},"que-faire-lorsque-le-quota-ia-ou-la-limite-journalière-est-atteint","Que faire lorsque le quota IA ou la limite journalière est atteint ?",[10,14715,14716],{},"Les fonctions IA ont deux limites : des limites journalières par utilisateur pour la reconnaissance de plans (30 analyses) et la reconnaissance d’un tableau depuis des photos (20 analyses), et le quota IA de votre compte, partagé par toutes les fonctions IA, dont la reconnaissance de plans, la reconnaissance d’un tableau depuis des photos et l’assistant PlanElec.",[35,14718,14719,14729],{},[38,14720,14721],{},[41,14722,14723,14725,14727],{},[44,14724,12112],{},[44,14726,12115],{},[44,14728,13816],{},[54,14730,14731,14742,14753,14764,14775],{},[41,14732,14733,14736,14739],{},[59,14734,14735],{},"« Le quota journalier de reconnaissances est épuisé. De nouveaux passages seront disponibles demain. »",[59,14737,14738],{},"Limite journalière de la reconnaissance de plans atteinte",[59,14740,14741],{},"Relancer le lendemain (UTC) ; d’ici là, redessiner le calque",[41,14743,14744,14747,14750],{},[59,14745,14746],{},"« Votre quota IA restant est insuffisant pour cette analyse. »",[59,14748,14749],{},"Quota IA trop faible pour cette analyse",[59,14751,14752],{},"Consulter le solde dans le menu utilisateur ; poursuivre sans IA",[41,14754,14755,14758,14761],{},[59,14756,14757],{},"« Du quota est réservé pour une analyse en cours. Réessayez dans quelques minutes. »",[59,14759,14760],{},"Une autre analyse est encore en cours",[59,14762,14763],{},"Patienter un instant et relancer",[41,14765,14766,14769,14772],{},[59,14767,14768],{},"« Trop de demandes. Veuillez réessayer plus tard. »",[59,14770,14771],{},"Limitation temporaire",[59,14773,14774],{},"Réessayer plus tard",[41,14776,14777,14779,14782],{},[59,14778,11594],{},[59,14780,14781],{},"Reconnaissance du tableau échouée, y compris lorsque la limite journalière est atteinte",[59,14783,14784],{},"Réessayer plus tard ou placer les modules manuellement",[10,14786,14787,14788,14790,14791,14794],{},"Le solde de votre quota figure dans le menu utilisateur (votre photo de profil) sous ",[19,14789,10982],{},", sous la forme « {percent} % disponible », ainsi que dans les paramètres sous ",[19,14792,14793],{},"IA et autorisations des données",". En dessous figure la date de son renouvellement : le quota se renouvelle chaque mois civil et le solde non utilisé n’est pas reporté. « Votre quota IA de ce mois est épuisé. » signifie : jusqu’à cette date, plus aucune analyse IA n’est disponible. Les analyses échouées facturées par le fournisseur consomment aussi ce quota.",[10,14796,14797,14798,14800,14801,4014],{},"Sans IA, vous poursuivez l’étude complète : importer le plan comme calque et le redessiner, placer les appareils depuis la palette, placer les modules dans le tableau. Sur l’assistant : ",[26,14799,5249],{"href":4730},". Sur la reconnaissance photo : ",[26,14802,14804],{"href":14803},"\u002Ffr\u002Fhelp\u002Freconnaitre-un-tableau-depuis-une-photo","Reconnaître un tableau depuis une photo",[10,14806,14807],{},[26,14808],{"id":14809},"fallback-3d",[30,14811,14813],{"id":14812},"pourquoi-la-vue-3d-naffiche-t-elle-quun-message","Pourquoi la vue 3D n’affiche-t-elle qu’un message ?",[10,14815,14816],{},"La vue 3D nécessite WebGL dans le navigateur. S’il manque ou si l’affichage 3D ne démarre pas, PlanElec remplace la scène par un message explicatif. Le plan de position reste entièrement utilisable en 2D.",[35,14818,14819,14829],{},[38,14820,14821],{},[41,14822,14823,14825,14827],{},[44,14824,12112],{},[44,14826,12115],{},[44,14828,13816],{},[54,14830,14831,14844],{},[41,14832,14833,14838,14841],{},[59,14834,14835,14837],{},[19,14836,13664],{}," : « Ce navigateur ne fournit pas WebGL. Le plan de position reste entièrement utilisable en 2D. »",[59,14839,14840],{},"Le navigateur ne fournit pas WebGL",[59,14842,14843],{},"Activer WebGL ou l’accélération matérielle dans le navigateur, ou utiliser un autre navigateur récent ; poursuivre en 2D",[41,14845,14846,14851,14854],{},[59,14847,14848,14850],{},[19,14849,13667],{}," : « La connexion graphique a été réinitialisée par le navigateur. »",[59,14852,14853],{},"Le navigateur a réinitialisé la connexion graphique",[59,14855,14856,14857],{},"Choisir ",[19,14858,14859],{},"Recharger",[10,14861,14862,14863,14866,14867,120,14870,14873,14874,4014],{},"La vue partagée ",[19,14864,14865],{},"2D + 3D"," n’est proposée que dans une large fenêtre d’ordinateur. Sur smartphone, vous choisissez entre ",[19,14868,14869],{},"2D",[19,14871,14872],{},"3D",". Pour aller plus loin : ",[26,14875,14877],{"href":14876},"\u002Ffr\u002Fhelp\u002Fvue-3d-et-etude-d-eclairage","Vue 3D et étude d’éclairage",[30,14879,14881],{"id":14880},"votre-problème-ne-figure-pas-ici","Votre problème ne figure pas ici ?",[10,14883,14884,14885,14888,14889,14891,14892,14894],{},"Commencez par le parcours de ",[26,14886,14887],{"href":6073},"Bien démarrer"," : de nombreux blocages disparaissent lorsque le plan de position, l’installation, le tableau et le schéma unifilaire sont complets, dans cet ordre. Consultez ensuite les constats ouverts dans le panneau ",[19,14890,4516],{}," et, dans ",[19,14893,3930],{},", le premier blocage de chaque document.",{"title":822,"searchDepth":823,"depth":823,"links":14896},[14897,14898,14899,14900,14901,14902,14903,14904,14905,14906,14907,14908,14909],{"id":13490,"depth":823,"text":13491},{"id":13684,"depth":823,"text":13685},{"id":13776,"depth":823,"text":13777},{"id":13879,"depth":823,"text":13880},{"id":13941,"depth":823,"text":13942},{"id":14171,"depth":823,"text":14172},{"id":14311,"depth":823,"text":14312},{"id":14412,"depth":823,"text":14413},{"id":14540,"depth":823,"text":14541},{"id":14583,"depth":823,"text":14584},{"id":14712,"depth":823,"text":14713},{"id":14812,"depth":823,"text":14813},{"id":14880,"depth":823,"text":14881},"Échelle manquante, appareil absent du schéma, export bloqué, longueur de câble ouverte, module non placé, message de synchronisation, limite IA ou message 3D : cause et solution par message.","troubleshooting","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Ftroubleshooting-fr.webp",{},16,"\u002Fhelp\u002Ftroubleshooting.fr",{"title":13482,"description":14910},"resoudre-les-problemes-courants","help\u002Ftroubleshooting.fr",[14920,4526,7772,14921,8162,14922],"dépannage","auto-contrôle","synchronisation","2026-10-17","huGUNcQBWUH9V7B_rVNUAyj1tSBADf6jJRCNferALMY",{"id":14926,"title":14927,"body":14928,"category":12654,"description":15979,"extension":846,"guideId":15980,"image":15981,"locale":849,"meta":15982,"navigation":851,"order":15983,"path":15984,"publishedAt":6105,"readTime":855,"seo":15985,"seoTitle":857,"slug":15986,"stem":15987,"tags":15988,"updatedAt":6105,"__hash__":15995},"help\u002Fhelp\u002Fview-3d-lighting-study.fr.md","Comment utiliser la vue 3D et l’étude d’éclairage ?",{"type":7,"value":14929,"toc":15966},[14930,14943,14947,14951,14954,15051,15057,15062,15066,15088,15096,15101,15105,15180,15183,15207,15238,15243,15248,15252,15255,15296,15301,15306,15310,15360,15373,15400,15405,15408,15413,15417,15420,15470,15473,15523,15526,15531,15535,15548,15580,15586,15591,15595,15610,15669,15672,15739,15742,15749,15753,15757,15827,15830,15834,15838,15933,15938,15942],[10,14931,14932,14933,14935,14936,120,14939,14942],{},"La vue 3D affiche le même état de projet que le plan 2D : étages, murs, ouvertures, escaliers, mobilier, appareils et chemins de câbles planifiés. Tous les utilisateurs y ont accès, sans activation particulière. Il vous faut un navigateur compatible WebGL ; à défaut, PlanElec affiche un message et vous continuez à travailler en 2D sans restriction. En mode ",[19,14934,4296],{},", vous placez les luminaires, comparez les scènes ",[19,14937,14938],{},"Quotidien",[19,14940,14941],{},"Soirée",", réglez la date et l’heure pour la position du soleil et les ombres, et lisez une carte d’éclairement avec des valeurs indicatives en lux. L’étude d’éclairage est une aide à la conception et à la discussion avec le client : elle calcule uniquement la lumière artificielle directe, sans réflexions, et ne remplace pas une étude d’éclairage normative.",[10,14944,14945],{},[26,14946],{"id":143},[30,14948,14950],{"id":14949},"de-quoi-ai-je-besoin-pour-la-vue-3d","De quoi ai-je besoin pour la vue 3D ?",[10,14952,14953],{},"Aucun abonnement ni rôle particulier n’est nécessaire. L’affichage de la 3D dépend de votre navigateur et de la largeur de votre espace de travail.",[35,14955,14956,14965],{},[38,14957,14958],{},[41,14959,14960,14962],{},[44,14961,9313],{},[44,14963,14964],{},"Ce que PlanElec affiche",[54,14966,14967,14979,14989,15001,15016,15029,15043],{},[41,14968,14969,14972],{},[59,14970,14971],{},"Navigateur avec WebGL",[59,14973,14974,14975,14978],{},"La vue 3D se charge avec le message ",[19,14976,14977],{},"Chargement de la vue 3D …",", puis affiche le modèle.",[41,14980,14981,14984],{},[59,14982,14983],{},"Navigateur sans WebGL",[59,14985,14986,14988],{},[19,14987,13664],{},". Le plan de position reste entièrement utilisable en 2D.",[41,14990,14991,14994],{},[59,14992,14993],{},"Connexion graphique réinitialisée par le navigateur",[59,14995,14996,14998,14999,4014],{},[19,14997,13667],{},", avec le bouton ",[19,15000,14859],{},[41,15002,15003,15006],{},[59,15004,15005],{},"Grand écran de bureau",[59,15007,15008,15009,4004,15011,120,15013,15015],{},"Sélecteur de vue avec ",[19,15010,14869],{},[19,15012,14872],{},[19,15014,14865],{}," (vue partagée à partir de 1600 pixels de largeur de l’espace de travail du studio).",[41,15017,15018,15021],{},[59,15019,15020],{},"Fenêtres plus étroites et tablettes",[59,15022,15023,15024,293,15026,15028],{},"Uniquement ",[19,15025,14869],{},[19,15027,14872],{},", une vue à la fois. Une vue partagée choisie bascule automatiquement vers une vue unique.",[41,15030,15031,15034],{},[59,15032,15033],{},"GSM en mode portrait",[59,15035,15036,15037,15039,15040,15042],{},"Sélecteur ",[19,15038,14869],{}," \u002F ",[19,15041,14872],{}," dans la barre d’en-tête, à côté du nom du projet.",[41,15044,15045,15048],{},[59,15046,15047],{},"Rôle lecteur",[59,15049,15050],{},"Vous voyez la 3D et l’étude d’éclairage, mais ne pouvez pas modifier le nom de scène, la luminosité ambiante ni les valeurs des luminaires.",[10,15052,15053,15054,15056],{},"Tant que le message remplace le modèle, les outils propres à la 3D et l’export en image de la scène lumineuse ne sont pas disponibles. Passez alors en ",[19,15055,14869],{}," avec le sélecteur de vue.",[10,15058,15059],{},[26,15060],{"id":15061},"open-3d",[30,15063,15065],{"id":15064},"comment-ouvrir-la-vue-3d","Comment ouvrir la vue 3D ?",[261,15067,15068,15071,15085],{},[152,15069,15070],{},"Ouvrez un projet dans le studio.",[152,15072,15073,15074,15076,15077,15079,15080,15039,15082,15084],{},"Dans le sélecteur de vue en haut de l’espace de travail, choisissez ",[19,15075,14872],{}," ou, sur un grand écran, ",[19,15078,14865],{},". Sur GSM, ",[19,15081,14869],{},[19,15083,14872],{}," se trouve dans la barre d’en-tête.",[152,15086,15087],{},"Le modèle apparaît avec l’étage actif. Résultat attendu : les murs, pièces et appareils de votre plan s’affichent en volume.",[10,15089,15090,15091,120,15093,15095],{},"Certains modes de travail s’ouvrent directement en 3D : ",[19,15092,4296],{},[19,15094,4306],{}," démarrent dans la vue 3D, les autres modes en 2D. La sélection et l’état du projet sont partagés entre 2D et 3D. Ce que vous sélectionnez dans une vue l’est aussi dans l’autre.",[10,15097,15098],{},[26,15099],{"id":15100},"navigation",[30,15102,15104],{"id":15103},"comment-se-déplacer-dans-la-vue-3d","Comment se déplacer dans la vue 3D ?",[35,15106,15107,15116],{},[38,15108,15109],{},[41,15110,15111,15114],{},[44,15112,15113],{},"Commande",[44,15115,484],{},[54,15117,15118,15126,15134,15142,15150,15157,15165,15172],{},[41,15119,15120,15123],{},[59,15121,15122],{},"Glisser avec le bouton gauche de la souris",[59,15124,15125],{},"Faire pivoter la vue",[41,15127,15128,15131],{},[59,15129,15130],{},"Glisser avec le bouton droit ou central, Maj + glisser",[59,15132,15133],{},"Déplacer la vue",[41,15135,15136,15139],{},[59,15137,15138],{},"Molette",[59,15140,15141],{},"Zoomer",[41,15143,15144,15147],{},[59,15145,15146],{},"Touches fléchées",[59,15148,15149],{},"Pivoter par pas de 5 degrés",[41,15151,15152,15155],{},[59,15153,15154],{},"Plus \u002F moins",[59,15156,15141],{},[41,15158,15159,15162],{},[59,15160,15161],{},"Touche 0",[59,15163,15164],{},"Réinitialiser la vue",[41,15166,15167,15170],{},[59,15168,15169],{},"Un doigt",[59,15171,7410],{},[41,15173,15174,15177],{},[59,15175,15176],{},"Deux doigts",[59,15178,15179],{},"Zoomer (écarter) et déplacer en même temps",[10,15181,15182],{},"En bas à gauche de l’image se trouvent les commandes de caméra :",[149,15184,15185,15191,15196],{},[152,15186,15187,15190],{},[19,15188,15189],{},"Ajuster la vue"," cadre l’ensemble du modèle.",[152,15192,15193,15195],{},[19,15194,15164],{}," rétablit la perspective de départ.",[152,15197,15198,15199,15202,15203,15206],{},"En cas de sélection s’ajoutent ",[19,15200,15201],{},"Afficher la sélection"," (la caméra se place sur l’objet choisi) et ",[19,15204,15205],{},"Ouvrir en 2D"," (retour au plan avec le même objet mis en évidence).",[10,15208,15209,15210,4004,15213,120,15216,15219,15220,120,15222,15224,15225,4004,15228,120,15231,15234,15235,15237],{},"Pour plusieurs niveaux, choisissez dans la barre des étages ou en haut à droite de l’image entre ",[19,15211,15212],{},"Étage actif",[19,15214,15215],{},"Empilés",[19,15217,15218],{},"Éclatés",". Dans les modes ",[19,15221,4267],{},[19,15223,4296],{},", un bouton supplémentaire alterne entre ",[19,15226,15227],{},"Murs hauts",[19,15229,15230],{},"Murs en coupe",[19,15232,15233],{},"Murs bas",". Les deux modes démarrent en coupe, pour que vous voyiez l’intérieur des pièces. En mode ",[19,15236,4091],{},", les murs restent entiers, car les appareils et les canalisations s’y trouvent. Ce choix est un réglage d’affichage et ne modifie pas votre projet.",[10,15239,15240,15241,4014],{},"La 3D reprend les hauteurs et la position des étages de votre plan. Pour superposer correctement les étages, consultez ",[26,15242,4398],{"href":4397},[10,15244,15245],{},[26,15246],{"id":15247},"furniture",[30,15249,15251],{"id":15250},"comment-meubler-les-pièces","Comment meubler les pièces ?",[10,15253,15254],{},"Le mobilier vous aide à placer prises, interrupteurs et luminaires en fonction de l’usage futur de la pièce. Il fait partie du plan et apparaît automatiquement en 3D.",[261,15256,15257,15262,15285,15288],{},[152,15258,15259,15260,4014],{},"Dans la barre des modes, choisissez ",[19,15261,4267],{},[152,15263,15264,15265,15268,15269,15272,15273,4004,15276,4004,15279,120,15282,4014],{},"Ouvrez le catalogue ",[19,15266,15267],{},"Mobilier et extérieur",". Les catégories vont de ",[19,15270,15271],{},"Séjour"," à ",[19,15274,15275],{},"Cuisine",[19,15277,15278],{},"Équipements de cuisine",[19,15280,15281],{},"Sanitaire",[19,15283,15284],{},"Extérieur",[152,15286,15287],{},"Choisissez un meuble et placez-le sur le plan.",[152,15289,15290,15291,293,15293,15295],{},"Passez en ",[19,15292,14872],{},[19,15294,14865],{},". Résultat attendu : le meuble se trouve dans la pièce au même endroit qu’en 2D.",[10,15297,4358,15298,15300],{},[19,15299,4267],{},", vous pouvez aussi saisir un meuble en 3D avec l’outil de sélection et le déplacer. Un simple clic sélectionne ; seul un véritable glissement déplace. Le relâchement constitue une étape annulable. Le catalogue regroupe des éléments d’aménagement courants ; ce n’est pas un catalogue fabricant complet. De nombreux appareils électriques apparaissent en 3D sous forme de volumes simplifiés, et non de modèles fidèles au produit.",[10,15302,15303],{},[26,15304],{"id":15305},"lighting-planning",[30,15307,15309],{"id":15308},"comment-placer-des-luminaires-en-mode-lumière","Comment placer des luminaires en mode Lumière ?",[261,15311,15312,15324,15331,15354],{},[152,15313,15259,15314,15316,15317,120,15320,15323],{},[19,15315,4296],{},". PlanElec ouvre la vue 3D avec les panneaux ",[19,15318,15319],{},"Planification de l’éclairage",[19,15321,15322],{},"Étude d’éclairage"," ; les calques des luminaires et de l’aperçu lumineux sont actifs, les câbles et les cotes masqués.",[152,15325,15326,15327,15330],{},"Placez les luminaires depuis la palette des appareils. Vous y trouvez aussi la ",[19,15328,15329],{},"Grille de spots"," : tracez un rectangle ou cliquez dans la pièce.",[152,15332,4723,15333,15335,15336,4004,15339,4004,15342,4004,15345,4004,15347,120,15350,15353],{},[19,15334,15319],{},", ajustez par pièce ",[19,15337,15338],{},"Flux lumineux (lm)",[19,15340,15341],{},"Température de couleur (K)",[19,15343,15344],{},"Angle du faisceau (°)",[19,15346,11870],{},[19,15348,15349],{},"Hauteur de montage (m)",[19,15351,15352],{},"Groupe",". Les luminaires identiques d’une pièce sont regroupés sur une ligne : vous les modifiez ensemble ou dépliez la ligne.",[152,15355,15356,15357,15359],{},"Si nécessaire, déplacez les luminaires directement en 3D : en mode ",[19,15358,4296],{},", l’outil de sélection saisit les luminaires. Les luminaires de plafond se déplacent librement dans la pièce, les appliques suivent le mur le plus proche.",[10,15361,15362,15363,15365,15366,293,15369,15372],{},"La colonne ",[19,15364,402],{}," indique ",[19,15367,15368],{},"Esquisse",[19,15370,15371],{},"Associé",". Une esquisse est un point lumineux sans lien avec le plan électrique. Pour l’associer :",[261,15374,15375,15385,15391],{},[152,15376,15377,15378,15381,15382,4014],{},"Ouvrez le ",[19,15379,15380],{},"Menu"," de la ligne et choisissez ",[19,15383,15384],{},"Relier à un circuit",[152,15386,3977,15387,15390],{},[19,15388,15389],{},"Circuit ou point lumineux existant",", choisissez la cible.",[152,15392,15393,15394,15397,15398,4014],{},"Confirmez avec ",[19,15395,15396],{},"Intégrer au plan électrique",". Résultat attendu : le statut passe à ",[19,15399,15371],{},[10,15401,15402,15403,4014],{},"Seule cette intégration crée un consommateur ou associe un point lumineux existant. PlanElec ne déduit ni la puissance ni le câblage de l’aperçu lumineux. Les commandes et les circuits se planifient comme d’habitude, voir ",[26,15404,8023],{"href":7981},[10,15406,15407],{},"Les nouveaux luminaires reçoivent un flux lumineux par défaut : suspension 800 lm, spot 400 lm, applique 300 lm. Saisissez les valeurs des luminaires réellement prévus avant d’interpréter la carte d’éclairement.",[10,15409,15410],{},[26,15411],{"id":15412},"light-preview",[30,15414,15416],{"id":15415},"comment-fonctionne-laperçu-lumineux-en-3d","Comment fonctionne l’aperçu lumineux en 3D ?",[10,15418,15419],{},"L’aperçu lumineux montre l’effet de la lumière artificielle de vos luminaires dans la pièce meublée. Il est illustratif : le panneau le présente explicitement comme « sans calcul de lux ni attestation d’éclairement ».",[261,15421,15422,15428,15438,15457,15464],{},[152,15423,4358,15424,7623,15426,4014],{},[19,15425,4296],{},[19,15427,15322],{},[152,15429,15430,15431,15433,15434,15437],{},"Dans la section ",[19,15432,4574],{},", activez le bouton ",[19,15435,15436],{},"Aperçu lumineux",". Il est désactivé à l’ouverture d’un projet.",[152,15439,15430,15440,15443,15444,120,15446,15448,15449,15452,15453,15456],{},[19,15441,15442],{},"Scène",", choisissez entre ",[19,15445,14938],{},[19,15447,14941],{},". Pour chaque scène, vous enregistrez un ",[19,15450,15451],{},"Nom de la scène",", la ",[19,15454,15455],{},"Luminosité ambiante"," et, par luminaire ou groupe, l’état allumé\u002Féteint et la variation.",[152,15458,15459,15460,15463],{},"Affichez les ",[19,15461,15462],{},"Faisceaux lumineux"," pour contrôler l’orientation et l’angle.",[152,15465,12678,15466,15469],{},[19,15467,15468],{},"Exporter la scène en image",", exportez un PNG de la caméra actuelle. Résultat attendu : l’image contient le nom de la scène et la mention de l’aperçu illustratif, sans marquage de sélection ni de survol.",[10,15471,15472],{},"Les scènes sont enregistrées par étage dans le projet et suivent l’annulation et la synchronisation du projet. Elles ne modifient ni le câblage ni les puissances électriques.",[35,15474,15475,15491],{},[38,15476,15477],{},[41,15478,15479,15482,15485,15488],{},[44,15480,15481],{},"Niveau de qualité",[44,15483,15484],{},"Luminaires actifs",[44,15486,15487],{},"dont avec ombres",[44,15489,15490],{},"Résolution des ombres",[54,15492,15493,15507],{},[41,15494,15495,15498,15501,15504],{},[59,15496,15497],{},"Standard",[59,15499,15500],{},"12",[59,15502,15503],{},"4",[59,15505,15506],{},"1024 px",[41,15508,15509,15514,15517,15520],{},[59,15510,15511],{},[19,15512,15513],{},"Qualité réduite",[59,15515,15516],{},"6",[59,15518,15519],{},"1",[59,15521,15522],{},"512 px",[10,15524,15525],{},"Sur les appareils tactiles, l’aperçu démarre en qualité réduite ; vous pouvez changer à tout moment. Les points lumineux au-delà de ce budget restent visibles sur le plan, mais n’éclairent pas la scène. Les surfaces des pièces et le mobilier reçoivent les ombres. Les modèles simplifiés et les murs de conception transparents limitent la portée de l’image.",[10,15527,15528],{},[26,15529],{"id":15530},"daylight",[30,15532,15534],{"id":15533},"comment-régler-la-position-du-soleil-et-les-ombres","Comment régler la position du soleil et les ombres ?",[10,15536,4723,15537,15539,15540,15543,15544,15547],{},[19,15538,15322],{},", la section ",[19,15541,15542],{},"Soleil"," s’intitule ",[19,15545,15546],{},"Étude de lumière naturelle · Site de Bruxelles",". Elle oriente en 3D une lumière solaire avec ombres portées.",[261,15549,15550,15561,15567,15574],{},[152,15551,15552,15553,15556,15557,15560],{},"Fixez l’",[19,15554,15555],{},"Orientation du nord"," : cliquez sur ",[19,15558,15559],{},"Définir le nord"," et faites glisser la flèche, ou indiquez si le nord est en haut, à droite, en bas ou à gauche du plan. 0° signifie nord en haut, la rotation se fait dans le sens horaire. L’orientation vaut pour tout le projet.",[152,15562,15563,15564,4014],{},"Choisissez une ",[19,15565,15566],{},"Date",[152,15568,15569,15570,15573],{},"Réglez l’",[19,15571,15572],{},"Heure"," avec le curseur, par pas de 10 minutes, dans le fuseau Europe\u002FBruxelles.",[152,15575,15576,15577,4014],{},"Lisez sous le curseur l’azimut et l’élévation du soleil. Résultat attendu : en 3D, la lumière et les ombres suivent l’heure. Si le soleil est sous l’horizon, le panneau affiche ",[19,15578,15579],{},"Soleil sous l’horizon",[10,15581,15582,15583,15585],{},"Le soleil et les ombres ne sont actifs qu’en mode ",[19,15584,4296],{},". La position du soleil est calculée par une approximation astronomique pour un site fixe à Bruxelles ; il n’existe pas encore de localisation propre au projet. Votre navigateur mémorise la date et l’heure par projet ; elles ne sont ni enregistrées dans le projet ni partagées. L’étude de lumière naturelle montre la direction du soleil et les ombres, mais ne calcule aucune valeur de lumière du jour en lux et n’entre pas dans la carte d’éclairement.",[10,15587,15588],{},[26,15589],{"id":15590},"heatmap",[30,15592,15594],{"id":15593},"que-montre-la-carte-déclairement","Que montre la carte d’éclairement ?",[10,15596,15597,15598,15601,15602,15604,15605,293,15607,15609],{},"La carte calcule, pour chaque pièce, l’éclairement direct de vos luminaires sur un plan de travail à 0,8 m. Elle apparaît en couleur sur le ",[19,15599,15600],{},"plan 2D",". Comme le mode ",[19,15603,4296],{}," démarre en 3D, passez en ",[19,15606,14869],{},[19,15608,14865],{}," pour la voir.",[261,15611,15612,15625,15630,15652],{},[152,15613,4723,15614,15616,15617,15620,15621,15624],{},[19,15615,15322],{},", ouvrez la section ",[19,15618,15619],{},"Éclairage"," et activez ",[19,15622,15623],{},"Carte d’éclairement"," (activée par défaut).",[152,15626,15290,15627,15629],{},[19,15628,14869],{},". Résultat attendu : les pièces équipées de luminaires sont colorées.",[152,15631,15632,15633,9914,15636,15639,15640,15643,15644,15647,15648,15651],{},"Lisez le tableau ",[19,15634,15635],{},"Résultats par pièce",[19,15637,15638],{},"Ē (lx)"," est la moyenne, ",[19,15641,15642],{},"Emin (lx)"," la valeur la plus basse, ",[19,15645,15646],{},"Emin\u002FĒ"," l’uniformité, ",[19,15649,15650],{},"Valeur indicative (lx)"," la valeur de comparaison.",[152,15653,15362,15654,15656,15657,15660,15661,15664,15665,15668],{},[19,15655,8896],{}," compare la moyenne à la valeur indicative basse : ",[19,15658,15659],{},"Atteint"," à partir de celle-ci, ",[19,15662,15663],{},"Légèrement inférieur"," à partir de 80 %, ",[19,15666,15667],{},"Trop faible"," en dessous.",[10,15670,15671],{},"Le calcul tient compte de l’intensité et de la variation de la scène active. Lorsque vous déplacez un luminaire, seule la pièce concernée est recalculée. Par étage, le calcul utilise au maximum 4 000 points de mesure.",[35,15673,15674,15684],{},[38,15675,15676],{},[41,15677,15678,15681],{},[44,15679,15680],{},"Type de pièce",[44,15682,15683],{},"Valeur indicative dans PlanElec",[54,15685,15686,15694,15701,15709,15717,15724,15732],{},[41,15687,15688,15691],{},[59,15689,15690],{},"Salon",[59,15692,15693],{},"100–200 lx",[41,15695,15696,15698],{},[59,15697,15275],{},[59,15699,15700],{},"300–500 lx",[41,15702,15703,15706],{},[59,15704,15705],{},"Salle de bain",[59,15707,15708],{},"200 lx",[41,15710,15711,15714],{},[59,15712,15713],{},"Couloir",[59,15715,15716],{},"100 lx",[41,15718,15719,15722],{},[59,15720,15721],{},"Chambre",[59,15723,15716],{},[41,15725,15726,15729],{},[59,15727,15728],{},"Bureau",[59,15730,15731],{},"500 lx",[41,15733,15734,15737],{},[59,15735,15736],{},"autres pièces",[59,15738,15716],{},[10,15740,15741],{},"Ces valeurs indicatives sont des repères utilisés par PlanElec pour l’état. Ce ne sont pas des exigences normatives, et le panneau précise sous le tableau que le résultat « ne constitue pas une étude d’éclairage normative ».",[10,15743,15744,15745,15748],{},"Une pièce affiche ",[19,15746,15747],{},"Non calculable"," si elle n’a aucun point de mesure ou si l’un de ses luminaires n’a pas de hauteur de montage connue supérieure à 0,8 m. Si la hauteur de montage manque dans la planification, PlanElec utilise les valeurs du type et de l’étage.",[10,15750,15751],{},[26,15752],{"id":180},[30,15754,15756],{"id":15755},"que-ne-calcule-pas-létude-déclairage","Que ne calcule pas l’étude d’éclairage ?",[35,15758,15759,15771],{},[38,15760,15761],{},[41,15762,15763,15765,15768],{},[44,15764,556],{},[44,15766,15767],{},"Ce que vous obtenez",[44,15769,15770],{},"Ce qui n’est pas inclus",[54,15772,15773,15784,15795,15806,15817],{},[41,15774,15775,15778,15781],{},[59,15776,15777],{},"Aperçu lumineux en 3D",[59,15779,15780],{},"Image illustrative avec scènes, variation et ombres",[59,15782,15783],{},"Aucune valeur en lux, aucune simulation photoréaliste ou physiquement exacte",[41,15785,15786,15789,15792],{},[59,15787,15788],{},"Carte et tableau",[59,15790,15791],{},"Composante directe à 0,8 m, moyenne, minimum, uniformité",[59,15793,15794],{},"Pas de réflexions, pas de lumière des pièces voisines, pas d’inclinaison des faisceaux, pas d’occultation par les murs",[41,15796,15797,15800,15803],{},[59,15798,15799],{},"Données des luminaires",[59,15801,15802],{},"Flux, température de couleur, angle du faisceau, hauteur de montage",[59,15804,15805],{},"Pas de photométrie fabricant (IES\u002FLDT), pas de géométrie fabricant, pas de rubans LED",[41,15807,15808,15811,15814],{},[59,15809,15810],{},"Étude de lumière naturelle",[59,15812,15813],{},"Direction du soleil et ombres en 3D pour Bruxelles",[59,15815,15816],{},"Pas de localisation propre, pas de valeurs de lumière du jour, pas de lumière du jour dans la carte",[41,15818,15819,15821,15824],{},[59,15820,11695],{},[59,15822,15823],{},"Aide à la conception et à l’entretien avec le client",[59,15825,15826],{},"Pas d’attestation d’éclairement ni de calcul d’éclairage normatif",[10,15828,15829],{},"Si vous avez besoin d’une justification opposable, calculez l’éclairage avec un logiciel d’éclairagisme et les données photométriques du fabricant. PlanElec vous fournit la géométrie des pièces, la position des points lumineux et les hauteurs de montage comme base de départ.",[10,15831,15832],{},[26,15833],{"id":14911},[30,15835,15837],{"id":15836},"pourquoi-je-ne-vois-ni-modèle-ni-ombres-ni-valeurs","Pourquoi je ne vois ni modèle, ni ombres, ni valeurs ?",[35,15839,15840,15848],{},[38,15841,15842],{},[41,15843,15844,15846],{},[44,15845,10301],{},[44,15847,11559],{},[54,15849,15850,15862,15873,15889,15900,15911,15923],{},[41,15851,15852,15856],{},[59,15853,15854],{},[19,15855,13664],{},[59,15857,15858,15859,15861],{},"Le navigateur ne fournit pas WebGL. Continuez en ",[19,15860,14869],{}," ou ouvrez le projet dans un navigateur récent avec accélération graphique.",[41,15863,15864,15868],{},[59,15865,15866],{},[19,15867,13667],{},[59,15869,15870,15871,4014],{},"Le navigateur a réinitialisé la connexion graphique. Cliquez sur ",[19,15872,14859],{},[41,15874,15875,15881],{},[59,15876,15877,15878,15880],{},"Pas de ",[19,15879,14865],{}," dans le sélecteur",[59,15882,15883,15884,120,15886,15888],{},"L’espace de travail fait moins de 1600 pixels de large. Utilisez ",[19,15885,14869],{},[19,15887,14872],{}," l’une après l’autre.",[41,15890,15891,15894],{},[59,15892,15893],{},"Pas d’ombres solaires",[59,15895,15896,15897,15899],{},"Le soleil et les ombres n’agissent qu’en mode ",[19,15898,4296],{},". Vérifiez aussi que le soleil est au-dessus de l’horizon à l’heure choisie.",[41,15901,15902,15905],{},[59,15903,15904],{},"Les luminaires n’éclairent pas en 3D",[59,15906,15907,15908,15910],{},"Activez ",[19,15909,15436],{},". Vérifiez l’état et la variation dans la scène active. Les luminaires au-delà du budget ne comptent pas.",[41,15912,15913,15918],{},[59,15914,15915],{},[19,15916,15917],{},"Aucun calcul : ajoutez des pièces ou activez le calque Aperçu lumineux.",[59,15919,15920,15921,4014],{},"Dessinez des pièces fermées ou activez le calque ",[19,15922,15436],{},[41,15924,15925,15930],{},[59,15926,15927,15929],{},[19,15928,15468],{}," est grisé",[59,15931,15932],{},"L’export nécessite une vue 3D visible et entièrement chargée.",[10,15934,15935,15936,4014],{},"Pour d’autres questions, consultez ",[26,15937,4705],{"href":4764},[30,15939,15941],{"id":15940},"pour-aller-plus-loin","Pour aller plus loin",[149,15943,15944,15948,15952,15956,15960],{},[152,15945,15946],{},[26,15947,4438],{"href":4437},[152,15949,15950],{},[26,15951,8023],{"href":7981},[152,15953,15954],{},[26,15955,4398],{"href":4397},[152,15957,15958],{},[26,15959,119],{"href":118},[152,15961,15962],{},[26,15963,15965],{"href":15964},"\u002Ffr\u002Fhelp\u002Fplanifier-une-installation-photovoltaique","Planifier une installation photovoltaïque",{"title":822,"searchDepth":823,"depth":823,"links":15967},[15968,15969,15970,15971,15972,15973,15974,15975,15976,15977,15978],{"id":14949,"depth":823,"text":14950},{"id":15064,"depth":823,"text":15065},{"id":15103,"depth":823,"text":15104},{"id":15250,"depth":823,"text":15251},{"id":15308,"depth":823,"text":15309},{"id":15415,"depth":823,"text":15416},{"id":15533,"depth":823,"text":15534},{"id":15593,"depth":823,"text":15594},{"id":15755,"depth":823,"text":15756},{"id":15836,"depth":823,"text":15837},{"id":15940,"depth":823,"text":15941},"La vue 3D est accessible à tous les utilisateurs. En mode Lumière, vous placez les luminaires, comparez des scènes, réglez la position du soleil et les ombres et lisez une carte d’éclairement indicative – sans calcul d’éclairage normatif.","view-3d-lighting-study","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fview-3d-lighting-study.webp",{},17,"\u002Fhelp\u002Fview-3d-lighting-study.fr",{"title":14927,"description":15979},"vue-3d-et-etude-d-eclairage","help\u002Fview-3d-lighting-study.fr",[15989,15990,15991,15992,15993,15994],"vue 3D","étude d’éclairage","éclairage","position du soleil","carte d’éclairement","mobilier","qP6ZguyP9yB32T_8MYzF2ioVPUnWlKpa-x1wp0Or4Dw",{"id":15997,"title":15998,"body":15999,"category":844,"description":16544,"extension":846,"guideId":16545,"image":16546,"locale":849,"meta":16547,"navigation":851,"order":16548,"path":16549,"publishedAt":16550,"readTime":8008,"seo":16551,"seoTitle":16552,"slug":16553,"stem":16554,"tags":16555,"updatedAt":16550,"__hash__":16560},"help\u002Fhelp\u002Foffline-work.fr.md","Utiliser PlanElec hors ligne : continuer vos projets sans connexion",{"type":7,"value":16000,"toc":16532},[16001,16012,16016,16020,16077,16080,16083,16087,16091,16094,16200,16203,16208,16212,16215,16223,16226,16231,16235,16238,16264,16269,16274,16278,16283,16298,16304,16309,16313,16382,16385,16389,16393,16461,16466,16470,16473,16476,16481,16485,16511,16513],[10,16002,16003,16004,16007,16008,16011],{},"Un projet que vous avez ouvert en ligne dans le studio, PlanElec le prépare automatiquement pour le travail sans connexion. Dès que l’indicateur affiche ",[19,16005,16006],{},"Prêt hors ligne",", vous continuez à modifier le plan, le schéma unifilaire et le tableau électrique sans réseau. Vos modifications restent sur l’appareil et se synchronisent avec le serveur à la reconnexion ; si elles contredisent une modification d’une autre session, c’est vous qui décidez. Exporter des documents, envoyer des pièces et des photos, utiliser l’assistant IA et la reconnaissance IA se fait dès que vous êtes de nouveau en ligne. Le travail hors ligne est en ",[19,16009,16010],{},"phase pilote"," : la fonction est activée sur planelec.be, l’essai sur chantier et sur tablette se poursuit. Testez donc le déroulement une fois avant un rendez-vous important.",[10,16013,16014],{},[26,16015],{"id":143},[30,16017,16019],{"id":16018},"de-quoi-ai-je-besoin-pour-travailler-hors-ligne","De quoi ai-je besoin pour travailler hors ligne ?",[35,16021,16022,16031],{},[38,16023,16024],{},[41,16025,16026,16028],{},[44,16027,10010],{},[44,16029,16030],{},"Pourquoi",[54,16032,16033,16041,16049,16057,16065],{},[41,16034,16035,16038],{},[59,16036,16037],{},"Ouvrir une fois le projet en ligne dans le studio",[59,16039,16040],{},"La préparation ne démarre que pour le projet ouvert et uniquement avec une connexion. Un projet jamais ouvert n’existe pas hors ligne.",[41,16042,16043,16046],{},[59,16044,16045],{},"Connexion valide à votre compte",[59,16047,16048],{},"Une copie locale ne naît que d’une session confirmée. Sans elle, vous voyez « Non prêt : Session valide requise ».",[41,16050,16051,16054],{},[59,16052,16053],{},"Synchronisation en direct activée",[59,16055,16056],{},"La préparation hors ligne s’appuie sur la synchronisation en direct. Elle est activée sur planelec.be ; il n’existe pas de réglage de votre côté.",[41,16058,16059,16062],{},[59,16060,16061],{},"Navigateur récent avec cache hors ligne",[59,16063,16064],{},"Sans service worker, PlanElec affiche « Non prêt : Le navigateur ne prend pas en charge le cache hors ligne ».",[41,16066,16067,16070],{},[59,16068,16069],{},"Espace libre et connexion adaptée",[59,16071,16072,16073,7633],{},"PlanElec ne télécharge les images de plan qu’avec au moins 200 Mo de réserve, ni en données mobiles ni en mode économie de données (voir ",[26,16074,16076],{"href":16075},"#limits","Limites",[10,16078,16079],{},"Aucune organisation n’est nécessaire. La synchronisation en direct relie aussi vos propres sessions sur plusieurs appareils.",[10,16081,16082],{},"Il n’y a pas de bouton « rendre disponible hors ligne ». PlanElec prépare le projet en arrière-plan pendant les moments calmes, revérifie l’état toutes les 30 secondes et reprend seul après une interruption.",[10,16084,16085],{},[26,16086],{"id":5606},[30,16088,16090],{"id":16089},"comment-savoir-quun-projet-est-prêt-hors-ligne","Comment savoir qu’un projet est prêt hors ligne ?",[10,16092,16093],{},"En bas à droite de la barre d’état se trouve un symbole d’état rond. L’info-bulle montre l’état d’enregistrement et l’état hors ligne ; un clic ouvre le détail : état d’enregistrement, disponibilité hors ligne et connexion.",[35,16095,16096,16106],{},[38,16097,16098],{},[41,16099,16100,16102,16104],{},[44,16101,4800],{},[44,16103,405],{},[44,16105,13396],{},[54,16107,16108,16120,16131,16142,16153,16166,16177,16189],{},[41,16109,16110,16114,16117],{},[59,16111,16112],{},[19,16113,16006],{},[59,16115,16116],{},"Le modèle du projet et toutes les images de plan sont vérifiés sur cet appareil.",[59,16118,16119],{},"Rien. Vous pouvez passer hors ligne.",[41,16121,16122,16125,16128],{},[59,16123,16124],{},"« Modèle disponible hors ligne · 2 images manquantes »",[59,16126,16127],{},"Vous pouvez travailler hors ligne, mais les images de plan indiquées manquent. La raison figure en dessous.",[59,16129,16130],{},"Corriger la raison (espace, Wi-Fi) ou travailler sans ces images.",[41,16132,16133,16136,16139],{},[59,16134,16135],{},"« Non prêt : Préparation… »",[59,16137,16138],{},"La préparation est en cours.",[59,16140,16141],{},"Laisser le projet ouvert et en ligne.",[41,16143,16144,16147,16150],{},[59,16145,16146],{},"« Non prêt : État local du projet pas encore disponible »",[59,16148,16149],{},"La copie locale du projet n’est pas encore enregistrée durablement.",[59,16151,16152],{},"Patienter ; si le message persiste, recharger la page en ligne.",[41,16154,16155,16158,16161],{},[59,16156,16157],{},"« Non prêt : Application pas encore disponible hors ligne »",[59,16159,16160],{},"L’application elle-même n’est pas encore entièrement enregistrée sur l’appareil.",[59,16162,16163,16164,4014],{},"Rester en ligne jusqu’à ",[19,16165,16006],{},[41,16167,16168,16171,16174],{},[59,16169,16170],{},"« Non prêt : Échec de l’enregistrement local »",[59,16172,16173],{},"Le navigateur n’a pas pu enregistrer la copie locale.",[59,16175,16176],{},"Vérifier l’espace libre ; PlanElec réessaie seul.",[41,16178,16179,16181,16184],{},[59,16180,14606],{},[59,16182,16183],{},"La synchronisation en direct est désactivée dans cet environnement. L’enregistrement normal sur le serveur continue.",[59,16185,16186,16187,10111],{},"Travailler en ligne ; vérifiez que ",[19,16188,4811],{},[41,16190,16191,16194,16197],{},[59,16192,16193],{},"« Une nouvelle version est disponible. Rechargez l’application pour la préparer à une utilisation hors ligne. »",[59,16195,16196],{},"Une version plus récente de PlanElec est active.",[59,16198,16199],{},"Recharger en ligne ; la préparation redémarre ensuite.",[10,16201,16202],{},"« Prêt hors ligne » est le dernier état vérifié. Le navigateur peut effacer lui-même des données locales en cas de manque d’espace ; PlanElec le constate à la vérification suivante et le signale.",[10,16204,16205],{},[26,16206],{"id":16207},"offline-scope",[30,16209,16211],{"id":16210},"que-puis-je-modifier-hors-ligne","Que puis-je modifier hors ligne ?",[10,16213,16214],{},"Hors ligne, vous modifiez tout ce qui est enregistré dans le modèle du projet : murs, pièces, appareils et chemins de câbles dans le plan, circuits dans le schéma unifilaire et occupation du tableau électrique, y compris les consignes de montage des appareils. Annuler et rétablir fonctionnent comme d’habitude.",[10,16216,16217,16218,293,16220,16222],{},"Sans connexion, le symbole d’état affiche ",[19,16219,4790],{},[19,16221,4841],{},", et le détail ajoute « Modification locale hors ligne. Les changements restent sur cet appareil ; les droits d’accès et la synchronisation sont vérifiés à la reconnexion. » PlanElec compte les modifications en attente, par exemple « 3 modifications en attente depuis 10:42 ».",[10,16224,16225],{},"Si vous rechargez la page sans connexion, PlanElec ouvre le projet préparé à partir de la copie locale. Vos modifications ne sont pas perdues.",[10,16227,16228],{},[26,16229],{"id":16230},"reconnect",[30,16232,16234],{"id":16233},"que-se-passe-t-il-quand-la-connexion-revient","Que se passe-t-il quand la connexion revient ?",[10,16236,16237],{},"PlanElec envoie lui-même les modifications en attente dès que le navigateur est de nouveau en ligne, quand vous revenez sur l’onglet, puis toutes les 30 secondes tant qu’il reste quelque chose à envoyer. Vous n’avez rien à lancer.",[261,16239,16240,16252,16255],{},[152,16241,16242,16243,293,16245,15272,16247,16249,16250,4014],{},"Le symbole d’état passe de ",[19,16244,4790],{},[19,16246,4841],{},[19,16248,4821],{},", puis à ",[19,16251,4811],{},[152,16253,16254],{},"Les modifications que d’autres ont faites entre-temps sur d’autres objets sont fusionnées avec les vôtres. Les deux sont conservées.",[152,16256,16257,16258,16260,16261,16263],{},"Avant la synchronisation, le serveur vérifie votre connexion et vos droits d’accès. Si votre session a expiré, ",[19,16259,14691],{}," s’affiche ; choisissez ",[19,16262,14699],{},". Si quelqu’un vous a retiré le droit de modification, PlanElec affiche « Vous n'avez plus l'autorisation de modifier ce projet. »",[10,16265,16266,16267,10111],{},"Si une tentative échoue, PlanElec attend un peu plus longtemps à chaque fois, cinq minutes au maximum, puis réessaie. Gardez l’onglet ouvert jusqu’à ce que ",[19,16268,4811],{},[10,16270,16271],{},[26,16272],{"id":16273},"conflicts",[30,16275,16277],{"id":16276},"que-faire-si-mes-modifications-hors-ligne-entrent-en-conflit-avec-dautres","Que faire si mes modifications hors ligne entrent en conflit avec d’autres ?",[10,16279,16280,16281,4014],{},"Si quelqu’un a modifié le même objet que vous, par exemple le même nom, PlanElec ne fusionne pas en silence. Vous voyez ",[19,16282,14647],{},[261,16284,16285,16290,16295],{},[152,16286,5031,16287,16289],{},[19,16288,14655],{},". Vous obtenez un fichier JSON avec l’état local de votre projet.",[152,16291,5031,16292,16294],{},[19,16293,14658],{}," et confirmez. Les modifications locales de cette session sont remplacées par la version enregistrée en commun ; les autres onglets conservent leurs modifications locales.",[152,16296,16297],{},"Saisissez à nouveau, dans l’état actuel, les modifications que vous souhaitez garder.",[10,16299,16300,16301,4014],{},"La sauvegarde ne contient pas les fichiers images, et PlanElec ne propose pas d’importer ce fichier. Conservez-le et contactez le support si vous devez en récupérer des éléments. Les autres messages d’enregistrement et de synchronisation sont expliqués dans ",[26,16302,4705],{"href":16303},"\u002Ffr\u002Fhelp\u002Fresoudre-les-problemes-courants#sync",[10,16305,16306],{},[26,16307],{"id":16308},"online-only",[30,16310,16312],{"id":16311},"que-dois-je-faire-une-fois-de-nouveau-en-ligne","Que dois-je faire une fois de nouveau en ligne ?",[35,16314,16315,16324],{},[38,16316,16317],{},[41,16318,16319,16321],{},[44,16320,8813],{},[44,16322,16323],{},"Pourquoi en ligne",[54,16325,16326,16337,16348,16356,16366,16374],{},[41,16327,16328,16334],{},[59,16329,16330,16331,16333],{},"Exporter des documents, ",[19,16332,4598],{},", archiver",[59,16335,16336],{},"L’export et l’archive ne font pas partie du travail hors ligne ; le serveur vérifie et scelle la version de remise.",[41,16338,16339,16342],{},[59,16340,16341],{},"Envoyer des pièces et des photos",[59,16343,16344,16345,16347],{},"Les fichiers se trouvent dans les ",[19,16346,711],{}," sur le serveur. Il n’existe pas de file d’attente d’envoi.",[41,16349,16350,16353],{},[59,16351,16352],{},"Reconnaître un plan avec l’IA, reconnaître un tableau depuis une photo",[59,16354,16355],{},"La reconnaissance s’exécute sur le serveur.",[41,16357,16358,16363],{},[59,16359,16360,16361],{},"Assistant IA dans le panneau ",[19,16362,4726],{},[59,16364,16365],{},"Le modèle de langage s’exécute sur le serveur.",[41,16367,16368,16371],{},[59,16369,16370],{},"Calculer la prévision de production PV",[59,16372,16373],{},"La simulation s’exécute sur le serveur.",[41,16375,16376,16379],{},[59,16377,16378],{},"Inviter des membres",[59,16380,16381],{},"Le serveur gère les invitations.",[10,16383,16384],{},"Planifiez ces étapes au bureau ou pendant une pause avec réseau. L’état modifié hors ligne est alors déjà synchronisé, et vous exportez à partir du projet à jour.",[10,16386,16387],{},[26,16388],{"id":180},[30,16390,16392],{"id":16391},"quelles-sont-les-limites-du-travail-hors-ligne","Quelles sont les limites du travail hors ligne ?",[35,16394,16395,16403],{},[38,16396,16397],{},[41,16398,16399,16401],{},[44,16400,193],{},[44,16402,4643],{},[54,16404,16405,16413,16421,16429,16437,16445,16453],{},[41,16406,16407,16410],{},[59,16408,16409],{},"Espace de stockage",[59,16411,16412],{},"PlanElec ne télécharge les images de plan que s’il reste ensuite au moins 200 Mo libres. Sinon : « Moins de 200 Mo libres ou espace disponible inconnu », seul le modèle est prêt hors ligne.",[41,16414,16415,16418],{},[59,16416,16417],{},"Données mobiles et économie de données",[59,16419,16420],{},"En mode économie de données, sur une connexion limitée ou mobile et en 2G, les téléchargements sont suspendus (« Économiseur de données activé », « Téléchargements suspendus sur une connexion limitée »). Certains navigateurs ne signalent pas le type de connexion ; PlanElec y télécharge aussi en données mobiles.",[41,16422,16423,16426],{},[59,16424,16425],{},"Images manquantes",[59,16427,16428],{},"L’affichage compte les images de plan manquantes. Le modèle reste modifiable, seul le fond de plan manque hors ligne. PlanElec charge d’abord l’étage actif.",[41,16430,16431,16434],{},[59,16432,16433],{},"Fichiers complémentaires",[59,16435,16436],{},"Les modèles 3D de mobilier et les sons d’interaction ne sont pas garantis hors ligne.",[41,16438,16439,16442],{},[59,16440,16441],{},"Appareil et navigateur",[59,16443,16444],{},"La copie locale ne vaut que pour ce navigateur sur cet appareil.",[41,16446,16447,16450],{},[59,16448,16449],{},"Fermer le projet, se déconnecter",[59,16451,16452],{},"Les deux annulent la préparation hors ligne. Rouvrez le projet en ligne avant de passer hors ligne.",[41,16454,16455,16458],{},[59,16456,16457],{},"Droits",[59,16459,16460],{},"Hors ligne, PlanElec ne vérifie pas les changements de droits. C’est à la reconnexion que l’accès actuel compte.",[10,16462,16463],{},[26,16464],{"id":16465},"install",[30,16467,16469],{"id":16468},"dois-je-installer-planelec-comme-application-web","Dois-je installer PlanElec comme application web ?",[10,16471,16472],{},"Non. Le travail hors ligne fonctionne aussi dans un onglet de navigateur ordinaire. En application web, vous obtenez une fenêtre dédiée sans barre de navigation et une icône sur l’écran d’accueil. Installez PlanElec via la fonction d’installation de votre navigateur, sur téléphone et tablette généralement via « Ajouter à l’écran d’accueil ». L’application s’ouvre sur l’aperçu des projets. Si vous la relancez, elle reprend la fenêtre ouverte au lieu d’en ouvrir une deuxième.",[10,16474,16475],{},"L’installation seule ne rend aucun projet prêt hors ligne. Seul compte l’indicateur d’état du projet ouvert. Sur téléphone et tablette, le studio garde l’écran allumé tant qu’il est visible.",[10,16477,16478],{},[26,16479],{"id":16480},"checklist",[30,16482,16484],{"id":16483},"comment-préparer-une-visite-de-chantier","Comment préparer une visite de chantier ?",[261,16486,16487,16490,16496,16499,16502,16508],{},[152,16488,16489],{},"Ouvrez le projet dans le studio en Wi-Fi, en commençant par l’étage dont vous aurez besoin sur place.",[152,16491,16492,16493,16495],{},"Attendez que l’indicateur affiche ",[19,16494,16006],{},". S’il signale des images manquantes, vérifiez la raison indiquée en dessous.",[152,16497,16498],{},"Laissez le projet ouvert. Ne le fermez pas et ne vous déconnectez pas.",[152,16500,16501],{},"Travaillez hors ligne dans une seule fenêtre par projet.",[152,16503,16504,16505,16507],{},"De retour sur le réseau : attendez ",[19,16506,4811],{}," avant de fermer l’onglet.",[152,16509,16510],{},"N’exportez les documents et n’envoyez les photos qu’ensuite.",[30,16512,15941],{"id":15940},[149,16514,16515,16519,16523,16528],{},[152,16516,16517],{},[26,16518,4705],{"href":4764},[152,16520,16521],{},[26,16522,4615],{"href":4614},[152,16524,16525],{},[26,16526,16527],{"href":4609},"Archiver et vérifier les documents",[152,16529,16530],{},[26,16531,14887],{"href":6073},{"title":822,"searchDepth":823,"depth":823,"links":16533},[16534,16535,16536,16537,16538,16539,16540,16541,16542,16543],{"id":16018,"depth":823,"text":16019},{"id":16089,"depth":823,"text":16090},{"id":16210,"depth":823,"text":16211},{"id":16233,"depth":823,"text":16234},{"id":16276,"depth":823,"text":16277},{"id":16311,"depth":823,"text":16312},{"id":16391,"depth":823,"text":16392},{"id":16468,"depth":823,"text":16469},{"id":16483,"depth":823,"text":16484},{"id":15940,"depth":823,"text":15941},"PlanElec prépare automatiquement les projets ouverts pour le travail sans connexion. Conditions, indicateur d’état, synchronisation à la reconnexion, conflits, limites et conseils avant une visite de chantier. Phase pilote.","offline-work","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Foffline-work-fr.webp",{},18,"\u002Fhelp\u002Foffline-work.fr","2026-10-12",{"title":15998,"description":16544},"Utiliser PlanElec hors ligne","utiliser-planelec-hors-ligne","help\u002Foffline-work.fr",[16556,16557,16558,14922,16559],"hors ligne","synchronisation en direct","application web","chantier","_G1WuV6_AbVBeulaMBO5A5naxF-YPtlSKFzzGRlvQ5c",{"id":4,"title":5,"body":16562,"category":844,"description":845,"extension":846,"guideId":847,"image":848,"locale":849,"meta":17146,"navigation":851,"order":852,"path":853,"publishedAt":854,"readTime":855,"seo":17147,"seoTitle":857,"slug":858,"stem":859,"tags":17148,"updatedAt":867,"__hash__":868},{"type":7,"value":16563,"toc":17126},[16564,16570,16574,16576,16640,16648,16652,16654,16672,16676,16678,16724,16728,16732,16734,16806,16810,16812,16866,16870,16872,16874,16926,16928,16932,16934,17020,17022,17026,17028,17032,17036,17038,17080,17082,17086,17088,17096,17098,17100,17102,17104,17106,17108,17114,17116,17118,17120,17122],[10,16565,12,16566,17,16568,22],{},[14,16567,16],{},[19,16569,21],{},[10,16571,16572],{},[26,16573],{"id":28},[30,16575,33],{"id":32},[35,16577,16578,16588],{},[38,16579,16580],{},[41,16581,16582,16584,16586],{},[44,16583,46],{},[44,16585,49],{},[44,16587,52],{},[54,16589,16590,16602,16616,16628],{},[41,16591,16592,16596,16600],{},[59,16593,61,16594,64],{},[14,16595,16],{},[59,16597,16598,70],{},[19,16599,69],{},[59,16601,73],{},[41,16603,16604,16608,16614],{},[59,16605,78,16606],{},[14,16607,16],{},[59,16609,83,16610,86,16612],{},[19,16611,69],{},[19,16613,89],{},[59,16615,73],{},[41,16617,16618,16622,16626],{},[59,16619,78,16620,98],{},[14,16621,16],{},[59,16623,101,16624],{},[19,16625,104],{},[59,16627,107],{},[41,16629,16630,16632,16638],{},[59,16631,112],{},[59,16633,115,16634,120,16636],{},[26,16635,119],{"href":118},[26,16637,124],{"href":123},[59,16639,73],{},[10,16641,129,16642,132,16644,135,16646,138],{},[14,16643,16],{},[19,16645,69],{},[14,16647,16],{},[10,16649,16650],{},[26,16651],{"id":143},[30,16653,147],{"id":146},[149,16655,16656,16660,16668],{},[152,16657,16658,157],{},[19,16659,156],{},[152,16661,16662,165,16666,169],{},[19,16663,162,16664],{},[14,16665,16],{},[14,16667,168],{},[152,16669,16670,175],{},[19,16671,174],{},[10,16673,16674],{},[26,16675],{"id":180},[30,16677,184],{"id":183},[35,16679,16680,16688],{},[38,16681,16682],{},[41,16683,16684,16686],{},[44,16685,193],{},[44,16687,196],{},[54,16689,16690,16698,16704,16712,16718],{},[41,16691,16692,16694],{},[59,16693,203],{},[59,16695,206,16696],{},[14,16697,16],{},[41,16699,16700,16702],{},[59,16701,213],{},[59,16703,216],{},[41,16705,16706,16710],{},[59,16707,221,16708,224],{},[14,16709,16],{},[59,16711,227],{},[41,16713,16714,16716],{},[59,16715,232],{},[59,16717,235],{},[41,16719,16720,16722],{},[59,16721,240],{},[59,16723,243],{},[10,16725,246,16726,250],{},[14,16727,249],{},[10,16729,16730],{},[26,16731],{"id":255},[30,16733,259],{"id":258},[261,16735,16736,16746,16756,16764,16772,16778,16784,16788,16798,16802],{},[152,16737,16738,268,16740,271,16742,275,16744,279],{},[19,16739,267],{},[19,16741,69],{},[19,16743,274],{},[19,16745,278],{},[152,16747,16748,285,16750,289,16752,293,16754,297],{},[19,16749,284],{},[19,16751,288],{},[19,16753,292],{},[19,16755,296],{},[152,16757,16758,303,16760,307,16762,311],{},[19,16759,302],{},[19,16761,306],{},[19,16763,310],{},[152,16765,16766,317,16768,321,16770,325],{},[19,16767,316],{},[19,16769,320],{},[19,16771,324],{},[152,16773,16774,331,16776,335],{},[19,16775,330],{},[19,16777,334],{},[152,16779,16780,341,16782,345],{},[19,16781,340],{},[19,16783,344],{},[152,16785,16786,351],{},[19,16787,350],{},[152,16789,16790,357,16792,361,16794,365,16796,369],{},[19,16791,356],{},[19,16793,360],{},[19,16795,364],{},[19,16797,368],{},[152,16799,16800,375],{},[19,16801,374],{},[152,16803,16804,381],{},[19,16805,380],{},[10,16807,384,16808,388],{},[19,16809,387],{},[390,16811,393],{"id":392},[35,16813,16814,16824],{},[38,16815,16816],{},[41,16817,16818,16820,16822],{},[44,16819,402],{},[44,16821,405],{},[44,16823,408],{},[54,16825,16826,16836,16846,16856],{},[41,16827,16828,16832,16834],{},[59,16829,16830],{},[19,16831,417],{},[59,16833,420],{},[59,16835,423],{},[41,16837,16838,16842,16844],{},[59,16839,16840],{},[19,16841,430],{},[59,16843,433],{},[59,16845,423],{},[41,16847,16848,16852,16854],{},[59,16849,16850],{},[19,16851,442],{},[59,16853,445],{},[59,16855,448],{},[41,16857,16858,16862,16864],{},[59,16859,16860],{},[19,16861,455],{},[59,16863,458],{},[59,16865,448],{},[10,16867,16868],{},[26,16869],{"id":465},[30,16871,469],{"id":468},[10,16873,472],{},[35,16875,16876,16884],{},[38,16877,16878],{},[41,16879,16880,16882],{},[44,16881,481],{},[44,16883,484],{},[54,16885,16886,16894,16902,16910,16918],{},[41,16887,16888,16892],{},[59,16889,16890],{},[19,16891,493],{},[59,16893,496],{},[41,16895,16896,16900],{},[59,16897,16898],{},[19,16899,89],{},[59,16901,505],{},[41,16903,16904,16908],{},[59,16905,16906],{},[19,16907,512],{},[59,16909,515],{},[41,16911,16912,16916],{},[59,16913,16914],{},[19,16915,522],{},[59,16917,525],{},[41,16919,16920,16924],{},[59,16921,16922],{},[19,16923,532],{},[59,16925,535],{},[10,16927,538],{},[10,16929,16930],{},[26,16931],{"id":543},[30,16933,547],{"id":546},[35,16935,16936,16946],{},[38,16937,16938],{},[41,16939,16940,16942,16944],{},[44,16941,556],{},[44,16943,559],{},[44,16945,562],{},[54,16947,16948,16956,16964,16972,16980,16988,16996,17004,17012],{},[41,16949,16950,16952,16954],{},[59,16951,569],{},[59,16953,572],{},[59,16955,575],{},[41,16957,16958,16960,16962],{},[59,16959,580],{},[59,16961,583],{},[59,16963,586],{},[41,16965,16966,16968,16970],{},[59,16967,591],{},[59,16969,594],{},[59,16971,597],{},[41,16973,16974,16976,16978],{},[59,16975,602],{},[59,16977,605],{},[59,16979,608],{},[41,16981,16982,16984,16986],{},[59,16983,613],{},[59,16985,616],{},[59,16987,586],{},[41,16989,16990,16992,16994],{},[59,16991,623],{},[59,16993,586],{},[59,16995,628],{},[41,16997,16998,17000,17002],{},[59,16999,633],{},[59,17001,636],{},[59,17003,586],{},[41,17005,17006,17008,17010],{},[59,17007,643],{},[59,17009,646],{},[59,17011,649],{},[41,17013,17014,17016,17018],{},[59,17015,654],{},[59,17017,586],{},[59,17019,659],{},[10,17021,662],{},[10,17023,17024],{},[26,17025],{"id":667},[30,17027,671],{"id":670},[10,17029,674,17030,677],{},[19,17031,324],{},[10,17033,17034],{},[26,17035],{"id":682},[30,17037,686],{"id":685},[35,17039,17040,17048],{},[38,17041,17042],{},[41,17043,17044,17046],{},[44,17045,695],{},[44,17047,698],{},[54,17049,17050,17058,17066,17074],{},[41,17051,17052,17054],{},[59,17053,705],{},[59,17055,708,17056,712],{},[19,17057,711],{},[41,17059,17060,17064],{},[59,17061,717,17062],{},[19,17063,532],{},[59,17065,722],{},[41,17067,17068,17072],{},[59,17069,727,17070],{},[19,17071,532],{},[59,17073,732],{},[41,17075,17076,17078],{},[59,17077,737],{},[59,17079,740],{},[10,17081,743],{},[10,17083,17084],{},[26,17085],{"id":748},[30,17087,752],{"id":751},[10,17089,755,17090,759,17092,763,17094,766],{},[19,17091,758],{},[19,17093,762],{},[19,17095,104],{},[30,17097,770],{"id":769},[390,17099,774],{"id":773},[10,17101,777],{},[390,17103,781],{"id":780},[10,17105,784],{},[390,17107,788],{"id":787},[10,17109,791,17110,794,17112,798],{},[19,17111,69],{},[26,17113,797],{"href":123},[390,17115,802],{"id":801},[10,17117,805],{},[390,17119,809],{"id":808},[10,17121,812],{},[10,17123,815,17124,820],{},[26,17125,819],{"href":818},{"title":822,"searchDepth":823,"depth":823,"links":17127},[17128,17129,17130,17131,17134,17135,17136,17137,17138,17139],{"id":32,"depth":823,"text":33},{"id":146,"depth":823,"text":147},{"id":183,"depth":823,"text":184},{"id":258,"depth":823,"text":259,"children":17132},[17133],{"id":392,"depth":831,"text":393},{"id":468,"depth":823,"text":469},{"id":546,"depth":823,"text":547},{"id":670,"depth":823,"text":671},{"id":685,"depth":823,"text":686},{"id":751,"depth":823,"text":752},{"id":769,"depth":823,"text":770,"children":17140},[17141,17142,17143,17144,17145],{"id":773,"depth":831,"text":774},{"id":780,"depth":831,"text":781},{"id":787,"depth":831,"text":788},{"id":801,"depth":831,"text":802},{"id":808,"depth":831,"text":809},{},{"title":5,"description":845},[861,16,862,863,864,865,866],{"id":17150,"title":17151,"body":17152,"category":5452,"description":18150,"extension":846,"guideId":18151,"image":18152,"locale":849,"meta":18153,"navigation":851,"order":18154,"path":18155,"publishedAt":18156,"readTime":18157,"seo":18158,"seoTitle":18159,"slug":18160,"stem":18161,"tags":18162,"updatedAt":18156,"__hash__":18167},"help\u002Fhelp\u002Fknx-ets-preparation.fr.md","Planifier et documenter une installation domotique : pas à pas avec l’exemple KNX",{"type":7,"value":17153,"toc":18134},[17154,17160,17170,17174,17227,17231,17235,17282,17288,17307,17311,17315,17348,17355,17358,17365,17376,17380,17384,17412,17419,17422,17426,17430,17458,17480,17486,17493,17496,17501,17505,17551,17556,17562,17567,17571,17604,17610,17615,17620,17624,17647,17701,17714,17721,17726,17730,17744,17751,17756,17760,17784,17789,17841,17844,17932,17937,17944,17948,17952,17979,17985,18026,18029,18033,18037,18099,18103,18114,18116],[10,17155,17156,17159],{},[19,17157,17158],{},"Dans le mode Domotique, vous planifiez et documentez une installation domotique depuis le même projet que le plan et le schéma unifilaire : choisir le système d’automatisation, placer les modules dans le tableau, affecter luminaires et volets aux canaux, relier boutons-poussoirs et détecteurs de mouvement, vérifier les lignes."," Il en résulte le plan des canaux pour la porte du tableau en PDF ou CSV, le plan des borniers, les fonctions par pièce, la topologie et les quantités, séparément ou dans le dossier domotique, en brouillon ou en version finale. Cela vaut pour KNX, Niko Home Control II, Loxone, Shelly, Sonoff et la planification neutre. La programmation des appareils reste dans le logiciel du fabricant.",[10,17161,17162,17163,17167,17168,4014],{},"Le guide suit un exemple KNX : un appartement belge fictif de sept pièces, avec un bouton-poussoir dans chaque pièce, un volet à chaque fenêtre et des détecteurs de mouvement dans le hall et la salle de bain. Pour KNX, deux sections s’ajoutent à la fin : les adresses proposées et des fichiers pour ETS. L’article ",[26,17164,17166],{"href":17165},"\u002Ffr\u002Fblog\u002Fplanifier-knx-appartement-preparation-ets","Documenter une installation domotique sur l’exemple d’un appartement KNX"," raconte toute l’histoire. Statut, version et empreinte des documents sont décrits dans ",[26,17169,8167],{"href":12816},[30,17171,17173],{"id":17172},"de-quoi-ai-je-besoin-avant-de-commencer","De quoi ai-je besoin avant de commencer ?",[35,17175,17176,17185],{},[38,17177,17178],{},[41,17179,17180,17183],{},[44,17181,17182],{},"Prérequis",[44,17184,16030],{},[54,17186,17187,17195,17203,17211,17219],{},[41,17188,17189,17192],{},[59,17190,17191],{},"Plan avec pièces",[59,17193,17194],{},"Les pièces rattachent points de commande et adresses de groupe au bon étage",[41,17196,17197,17200],{},[59,17198,17199],{},"Luminaires et volets placés",[59,17201,17202],{},"Ce sont les récepteurs que vous affectez aux canaux des actionneurs",[41,17204,17205,17208],{},[59,17206,17207],{},"Circuits avec protection",[59,17209,17210],{},"Chaque charge commutée a besoin de son disjoncteur dans le schéma unifilaire",[41,17212,17213,17216],{},[59,17214,17215],{},"Tableau avec un rail DIN libre",[59,17217,17218],{},"PlanElec y place les modules d’automatisation",[41,17220,17221,17224],{},[59,17222,17223],{},"Rôle de projet avec droit de modification",[59,17225,17226],{},"En lecture seule, vous voyez la planification sans pouvoir la modifier",[10,17228,17229],{},[26,17230],{"id":8256},[30,17232,17234],{"id":17233},"comment-choisir-le-système-dautomatisation","Comment choisir le système d’automatisation ?",[261,17236,17237,17245,17269],{},[152,17238,17239,17240,4551,17242,11139],{},"Dans la barre des modes à gauche, choisissez ",[19,17241,4286],{},[19,17243,17244],{},"Canaux",[152,17246,11828,17247,17250,17251,4004,17253,4004,17256,4004,17259,4004,17262,293,17265,17268],{},[19,17248,17249],{},"Systèmes d’automatisation",", cliquez sur votre système : ",[19,17252,8614],{},[19,17254,17255],{},"Niko Home Control II",[19,17257,17258],{},"Loxone",[19,17260,17261],{},"Shelly Pro \u002F Plus",[19,17263,17264],{},"Sonoff",[19,17266,17267],{},"Générique \u002F configurable",". PlanElec propose ensuite les modules, points de commande et types de ligne de ce système. Dans l’exemple, c’est KNX.",[152,17270,17271,17272,17275,17276,15365,17279,4014],{},"Vous reconnaissez le succès aux ",[19,17273,17274],{},"Étapes de planification domotique"," : l’étape 1 ",[19,17277,17278],{},"Système",[19,17280,17281],{},"Actif",[4534,17283],{":height":17284,":width":9102,"alt":17285,"caption":17286,"src":17287},"588","Étapes de planification domotique : Système actif, Modules, Récepteurs, Lignes et Export encore ouverts ; dessous, le formulaire Placer un module avec Module et Rail.","Les cinq étapes de planification affichent l’état ; juste en dessous, vous placez le premier module.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-setup-guide.webp",[10,17289,17290,17291,4004,17293,4004,17296,4004,17299,120,17301,17303,17304,17306],{},"Les cinq étapes de planification sont ",[19,17292,17278],{},[19,17294,17295],{},"Modules",[19,17297,17298],{},"Récepteurs",[19,17300,8358],{},[19,17302,3930],{},". Chaque étape indique son état, par exemple « Canaux : 12 » ou « Affectés : 17 sur 17 », et vous amène en un clic là où il reste quelque chose à faire. Vous pouvez aussi choisir le système dans les métadonnées du projet sous ",[19,17305,4286],{}," ; l’effet est le même. Un projet peut gérer plusieurs systèmes.",[10,17308,17309],{},[26,17310],{"id":8318},[30,17312,17314],{"id":17313},"comment-documenter-le-tableau-avec-modules-rails-et-borniers","Comment documenter le tableau avec modules, rails et borniers ?",[261,17316,17317,17323,17329,17337],{},[152,17318,17319,17320,4014],{},"Sous les étapes de planification, ouvrez ",[19,17321,17322],{},"Placer un module",[152,17324,3977,17325,17328],{},[19,17326,17327],{},"Module",", choisissez le modèle. La liste montre les modules du système choisi, classés par famille d’appareils ; pour KNX par exemple alimentation, coupleur de ligne, interface IP, actionneurs de commutation, de volets, de variation et de chauffage et entrées binaires, en version neutre et en types ABB i-bus avec leur référence de commande.",[152,17330,3977,17331,17334,17335,4014],{},[19,17332,17333],{},"Rail",", choisissez le rail DIN du tableau et cliquez sur ",[19,17336,14562],{},[152,17338,17339,17340,17343,17344,17347],{},"PlanElec place le module au premier emplacement libre, crée ses canaux et affecte l’alimentation, les appareils bus et les points de commande à la ligne du système, la ligne par défaut ",[19,17341,17342],{},"1.1"," pour KNX. Le message « … placé, canaux créés. » confirme l’étape ; ",[19,17345,17346],{},"Placer un autre module"," rouvre le formulaire.",[4534,17349],{":height":17350,":width":17351,"alt":17352,"caption":17353,"src":17354},"828","440","Liste des modules ouverte dans Placer un module : alimentation KNX, ABB SV\u002FS 30.640.5.1, ABB SV\u002FS 30.320.2.1, coupleurs de ligne et interfaces IP, classés par famille.","Modèles neutres et types ABB i-bus figurent dans la même liste, classés par famille.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-quick-place-templates.webp",[10,17356,17357],{},"Dans l’appartement d’exemple, le rail « KNX 1 » reçoit une ABB SV\u002FS 30.640.5.1 (alimentation 640 mA), une ABB IPS\u002FS 3.1.1 (interface IP) et un ABB SA\u002FS 12.16.2.2 (actionneur de commutation 12 canaux) ; le rail « KNX 2 » reçoit un actionneur de volet 8× et un actionneur de variation 4× neutres. Le tableau représente les types ABB dans le style du fabricant, avec borne de bus rouge et noire.",[4534,17359],{":height":17360,":width":17361,"alt":17362,"caption":17363,"src":17364},"287","452","Tableau avec deux rails KNX : alimentation, interface IP et actionneur de commutation 12 canaux sur KNX 1, actionneurs de volet et de variation sur KNX 2, les types ABB avec borne de bus rouge et noire.","Les modules placés dans le tableau, les types ABB avec borne de bus rouge et noire.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-cabinet-knx-rows.webp",[10,17366,17367,17368,17370,17371,4880,17373,17375],{},"Dans l’éditeur de tableau (panneau ",[19,17369,4480],{},"), les modules d’automatisation côtoient l’interrupteur général, les différentiels et les disjoncteurs. Vous y gérez les borniers et le câblage. Les bornes des canaux d’automatisation, avec réglettes, destinations et ponts, se gèrent dans le panneau ",[19,17372,17244],{},[19,17374,8364],{},". Les références de commande et le courant bus des types ABB proviennent des données du fabricant. Vérifiez-les sur la fiche technique avant de commander. ABB est une marque du groupe ABB ; PlanElec n’est pas partenaire d’ABB.",[10,17377,17378],{},[26,17379],{"id":8280},[30,17381,17383],{"id":17382},"comment-planifier-boutons-poussoirs-et-détecteurs-de-mouvement","Comment planifier boutons-poussoirs et détecteurs de mouvement ?",[261,17385,17386,17389,17409],{},[152,17387,17388],{},"Fermez le panneau pour libérer le plan et ouvrez le catalogue.",[152,17390,5432,17391,17393,17394,17397,17398,17397,17401,17404,17405,17408],{},[19,17392,8290],{},", choisissez un ",[19,17395,17396],{},"Bouton-poussoir",", un ",[19,17399,17400],{},"Bouton-poussoir double",[19,17402,17403],{},"Bouton-poussoir quadruple"," ou un ",[19,17406,17407],{},"Détecteur de mouvement"," et cliquez sur le mur ou le plafond de la pièce.",[152,17410,17411],{},"Le plan affiche le symbole dans la pièce. Les points de commande bus rejoignent sans autre étape la ligne de leur système, la ligne 1.1 pour KNX.",[4534,17413],{":height":17414,":width":17415,"alt":17416,"caption":17417,"src":17418},"642","711","Plan de l’appartement de sept pièces : un bouton-poussoir près de chaque porte, des détecteurs de mouvement dans le hall et la salle de bain, des volets à toutes les fenêtres et des luminaires dans chaque pièce.","Un bouton-poussoir par pièce, des détecteurs de mouvement dans le hall et la salle de bain, des volets aux sept fenêtres.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-floorplan-controls.webp",[10,17420,17421],{},"Lors de la proposition d’adresses, les détecteurs de mouvement et de présence reçoivent deux objets propres : un objet de commutation (DPT 1.001), lié à l’adresse de groupe de commutation du canal d’éclairage, et un objet de luminosité (DPT 9.004). Un bouton-poussoir ne reçoit pas d’adresse de groupe propre ; ses touches renvoient aux adresses de groupe des canaux qu’elles commandent.",[10,17423,17424],{},[26,17425],{"id":8321},[30,17427,17429],{"id":17428},"comment-affecter-récepteurs-et-boutons-poussoirs-aux-canaux","Comment affecter récepteurs et boutons-poussoirs aux canaux ?",[10,17431,4723,17432,17434,17435,17438,17439,4004,17442,4004,17444,4004,17447,4004,17450,4004,17453,120,17455,4014],{},[19,17433,17244],{},", choisissez la vue ",[19,17436,17437],{},"Matrice des canaux",". Le tableau des canaux montre un groupe par module avec tableau, rail, emplacement, type et ligne, puis chaque canal avec ",[19,17440,17441],{},"Type de canal",[19,17443,17298],{},[19,17445,17446],{},"Pièce",[19,17448,17449],{},"Commandes",[19,17451,17452],{},"Borne",[19,17454,6162],{},[19,17456,17457],{},"Ligne \u002F AP",[261,17459,17460,17470,17477],{},[152,17461,17462,17463,17465,17466,17469],{},"Dans la colonne ",[19,17464,17298],{},", cliquez sur ",[19,17467,17468],{},"+"," et choisissez le luminaire ou le volet. PlanElec propose les charges compatibles avec le type de canal.",[152,17471,17462,17472,17465,17474,17476],{},[19,17473,17449],{},[19,17475,17468],{}," et choisissez le bouton-poussoir ou le détecteur de mouvement.",[152,17478,17479],{},"Répétez l’opération pour chaque canal. La pièce et la protection viennent du projet ; vous ne les saisissez pas deux fois.",[10,17481,17482,17485],{},[19,17483,17484],{},"Proposer par pièce"," répartit les récepteurs non affectés sur les canaux libres, selon la pièce et le type de canal. Les affectations existantes sont conservées. Vérifiez ensuite la proposition canal par canal.",[4534,17487],{":height":17488,":width":17489,"alt":17490,"caption":17491,"src":17492},"811","1322","Tableau des canaux de l’ABB SA\u002FS 12.16.2.2 : CH1 à CH7 avec plafonniers, ruban LED et applique miroir, boutons-poussoirs et détecteurs de mouvement, pièce, disjoncteur et ligne KNX 1.1 ; CH8 à CH12 en réserve ; dessous, l’actionneur de variation avec l’avertissement de courant nominal inconnu.","Sept canaux de commutation affectés, cinq réserves ; pour l’actionneur de variation, PlanElec signale le courant nominal manquant.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-channels-assigned.webp",[10,17494,17495],{},"À droite de chaque ligne figure le constat du canal. Une coche signifie : aucune donnée de planification en suspens. Un point d’exclamation indique ce qui manque, dans l’exemple « Le courant nominal du canal est inconnu ; vérifiez l’appareil et renseignez sa valeur. » pour l’actionneur de variation neutre. D’autres constats signalent par exemple une charge affectée deux fois, une charge sans protection, un type de canal inadapté ou une surcharge. Ces constats sont des contrôles de planification ; l’autocontrôle RGIE du projet reste distinct.",[10,17497,17498],{},[26,17499],{"id":17500},"lines",[30,17502,17504],{"id":17503},"comment-vérifier-les-lignes-et-le-budget-bus","Comment vérifier les lignes et le budget bus ?",[261,17506,17507,17513,17527,17538,17544],{},[152,17508,4723,17509,17434,17511,4014],{},[19,17510,17244],{},[19,17512,8358],{},[152,17514,4017,17515,17518,17519,17522,17523,17526],{},[19,17516,17517],{},"Préaffecter les appareils non affectés"," s’il reste des appareils bus sans ligne. ",[19,17520,17521],{},"Ajouter : Ligne KNX"," crée une ligne supplémentaire, ",[19,17524,17525],{},"Créer la zone 2"," une zone supplémentaire. Chaque ligne a sa propre couleur et porte son adresse comme nom, par exemple « KNX 1.1 ».",[152,17528,17529,17530,17533,17534,17537],{},"Dans la carte de la ligne, choisissez le ",[19,17531,17532],{},"Module d’alimentation"," et la ",[19,17535,17536],{},"Capacité d’alimentation (mA)",", par exemple 640 mA.",[152,17539,3977,17540,17543],{},[19,17541,17542],{},"Courant de bus (mA)",", saisissez la valeur de la fiche technique lorsque vous la connaissez.",[152,17545,17546,17547,17550],{},"Déplacez les appareils d’une ligne à l’autre par glisser-déposer, plusieurs à la fois via les cases à cocher ; sans souris via ",[19,17548,17549],{},"Déplacer vers",". Les adresses physiques non verrouillées suivent la ligne.",[4534,17552],{":height":17488,":width":17489,"alt":17553,"caption":17554,"src":17555},"Vue Lignes avec la ligne KNX 1.1 dans la zone 1, poignées de déplacement et cases à cocher par appareil, module d’alimentation ABB SV\u002FS 30.640.5.1, capacité 640 mA, budget de 132 mA sur 640 mA dont 11 appareils estimés, 13 appareils pour une limite de 64.","Ligne 1.1 : 132 mA sur 640 mA, dont onze appareils au courant bus estimé ; 13 participants sur 64.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-lines-budget.webp",[10,17557,17558,17559,4014],{},"Le budget compare le courant bus à l’alimentation et le nombre d’appareils à la limite de 64 participants par ligne. Les valeurs que vous n’avez pas saisies, PlanElec les estime à partir de valeurs typiques et les marque comme « estimé ». Avant la mise en service, comparez-les aux fiches techniques. Une ligne est un état de planification logique, pas un chemin de câble mesuré ; le câble de bus se dessine sur le plan avec ",[19,17560,17561],{},"Poser le bus",[10,17563,17564],{},[26,17565],{"id":17566},"functions",[30,17568,17570],{"id":17569},"comment-créer-fonctions-scènes-et-fonctions-centrales","Comment créer fonctions, scènes et fonctions centrales ?",[261,17572,17573,17579,17585,17601],{},[152,17574,4723,17575,17434,17577,4014],{},[19,17576,17244],{},[19,17578,8532],{},[152,17580,17581,17584],{},[19,17582,17583],{},"Ajouter une scène"," ouvre l’éditeur de scène. Donnez un nom, par exemple « Absence », choisissez les canaux et leur valeur cible : allumé ou éteint pour la commutation, un pourcentage pour la variation et les volets.",[152,17586,17587,120,17590,17593,17594,17597,17598,17600],{},[19,17588,17589],{},"Central : tout éteindre",[19,17591,17592],{},"Central : fermer les volets"," créent en un clic les fonctions centrales habituelles. ",[19,17595,17596],{},"Fonction depuis un canal"," suivi de ",[19,17599,4020],{}," transforme un canal isolé en fonction.",[152,17602,17603],{},"Les fonctions apparaissent dans les fonctions par pièce. Pour KNX, scènes et fonctions centrales reçoivent leurs propres adresses de groupe lors de la proposition d’adresses (voir plus bas).",[4534,17605],{":height":17606,":width":9102,"alt":17607,"caption":17608,"src":17609},"799","Éditeur de scène nommée Absence : tous les canaux de commutation et de variation éteints, les sept volets à 100 pour cent.","Scène « Absence » : éclairage éteint, tous les volets fermés.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-scene-editor.webp",[4534,17611],{":height":17606,":width":9102,"alt":17612,"caption":17613,"src":17614},"Vue Fonctions et scènes avec les boutons Ajouter une scène, Central : tout éteindre et Central : fermer les volets, et la scène Absence avec 17 participants.","La scène « Absence » avec 17 participants ; les fonctions centrales suivent dans la même liste.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-functions.webp",[10,17616,17617],{},[26,17618],{"id":17619},"documents",[30,17621,17623],{"id":17622},"quels-documents-pour-la-porte-du-tableau-le-montage-et-la-remise","Quels documents pour la porte du tableau, le montage et la remise ?",[261,17625,17626,17633,17636],{},[152,17627,17239,17628,17630,17631,4014],{},[19,17629,3930],{}," et faites défiler jusqu’à la section ",[19,17632,4286],{},[152,17634,17635],{},"Choisissez le tableau, le tri (module, protection, pièce ou borne), la version et le statut.",[152,17637,17638,17639,13284,17641,17643,17644,17646],{},"Chaque document a un ",[19,17640,4574],{},[19,17642,6028],{}," ; le plan des canaux et le plan des borniers existent aussi en CSV, la topologie en SVG. ",[19,17645,8388],{}," réunit le tout derrière une page de garde.",[35,17648,17649,17657],{},[38,17650,17651],{},[41,17652,17653,17655],{},[44,17654,5500],{},[44,17656,9196],{},[54,17658,17659,17666,17673,17680,17687,17694],{},[41,17660,17661,17663],{},[59,17662,8344],{},[59,17664,17665],{},"tableau, module, canal, récepteur, pièce, protection, borne, point de commande ; A4 paysage pour la porte du tableau",[41,17667,17668,17670],{},[59,17669,8364],{},[59,17671,17672],{},"réglettes, bornes, destinations et ponts par tableau",[41,17674,17675,17677],{},[59,17676,8422],{},[59,17678,17679],{},"les touches et les charges qu’elles commandent ; scènes et fonctions centrales",[41,17681,17682,17684],{},[59,17683,8430],{},[59,17685,17686],{},"lignes logiques du projet, aussi en SVG",[41,17688,17689,17691],{},[59,17690,8438],{},[59,17692,17693],{},"modules, alimentations, points de commande et câbles de signal en nombre, sans prix",[41,17695,17696,17698],{},[59,17697,8446],{},[59,17699,17700],{},"rapport d’autocontrôle avec constats et limites de contrôle",[10,17702,8341,17703,17706,17707,17710,17711,4014],{},[19,17704,17705],{},"brouillon"," porte un filigrane et reste possible avec des données ouvertes. La version ",[19,17708,17709],{},"finale"," exige que l’export soit prêt ; l’interface indique les points ouverts et propose de traiter le prochain point ouvert. Statut, version et empreinte des données sont expliqués dans ",[26,17712,8167],{"href":17713},"\u002Ffr\u002Fhelp\u002Fplanifier-et-documenter-le-knx#export",[4534,17715],{":height":17716,":width":17717,"alt":17718,"caption":17719,"src":17720},"764","1126","Section Domotique de l’export avec le choix du tableau, du tri, de la version et du statut, et les cartes des documents domotiques.","Documents domotiques dans l’export : tableau, tri, version et brouillon ou final.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-export-domotica.webp",[10,17722,17723],{},[26,17724],{"id":17725},"team",[30,17727,17729],{"id":17728},"comment-régler-les-points-ouverts-en-équipe","Comment régler les points ouverts en équipe ?",[10,17731,17732,17733,17736,17737,5943,17740,17743],{},"Dans le tableau, sélectionnez un module et ouvrez, dans ",[19,17734,17735],{},"Propriétés du module",", l’icône de bulle à côté du nom du module. Vous y écrivez un commentaire directement sur le module, par exemple à propos d’un courant bus qui doit encore venir de la fiche technique. Dans le panneau ",[19,17738,17739],{},"Notes et tâches",[19,17741,17742],{},"Tâches",", vous créez une tâche et l’attribuez. Les approbations des documents archivés passent par la même zone.",[4534,17745],{":height":17746,":width":17747,"alt":17748,"caption":17749,"src":17750},"852","1372","Tableau avec l’ABB SA\u002FS 12.16.2.2 sélectionné et un commentaire ouvert dans les propriétés du module : merci de reprendre la consommation bus des détecteurs depuis la fiche technique.","Commentaire directement sur l’actionneur de commutation ; le chiffre sur l’icône indique le nombre de messages.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-collaboration-module-thread.webp",[10,17752,17753],{},[26,17754],{"id":17755},"addresses",[30,17757,17759],{"id":17758},"knx-uniquement-comment-planelec-propose-t-il-les-adresses-physiques-et-les-adresses-de-groupe","KNX uniquement : comment PlanElec propose-t-il les adresses physiques et les adresses de groupe ?",[261,17761,17762,17768,17779],{},[152,17763,4723,17764,17434,17766,4014],{},[19,17765,17244],{},[19,17767,8506],{},[152,17769,17770,17771,9914,17774,17776,17777,4014],{},"Choisissez la ",[19,17772,17773],{},"Structure des adresses de groupe",[19,17775,8510],{}," (par défaut) ou ",[19,17778,8514],{},[152,17780,4017,17781,17783],{},[19,17782,8517],{},". La ligne en dessous donne le résultat, dans l’exemple « 13 adresses physiques et 61 adresses de groupe proposées. ». La proposition s’annule en une étape.",[4534,17785],{":height":17488,":width":17489,"alt":17786,"caption":17787,"src":17788},"Adresses KNX : structure Corps de métier \u002F étage \u002F objet, bouton Proposer les adresses, puis la ligne 1.1 avec l’alimentation sans adresse, l’interface IP 1.1.1, l’actionneur de commutation 1.1.2, l’actionneur de volet 1.1.3, l’actionneur de variation 1.1.4, puis boutons-poussoirs et détecteurs de mouvement avec leur pièce à partir de 1.1.5.","Adresses physiques de la ligne 1.1 : d’abord les modules dans l’ordre du tableau, puis les points de commande par pièce.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-addresses-physical.webp",[35,17790,17791,17800],{},[38,17792,17793],{},[41,17794,17795,17798],{},[44,17796,17797],{},"Règle",[44,17799,10284],{},[54,17801,17802,17809,17817,17825,17833],{},[41,17803,17804,17806],{},[59,17805,6914],{},[59,17807,17808],{},"x.y.0",[41,17810,17811,17814],{},[59,17812,17813],{},"Alimentation",[59,17815,17816],{},"pas d’adresse physique",[41,17818,17819,17822],{},[59,17820,17821],{},"Actionneurs et interfaces",[59,17823,17824],{},"à partir de x.y.1 dans l’ordre du tableau (tableau, rail, emplacement)",[41,17826,17827,17830],{},[59,17828,17829],{},"Points de commande bus",[59,17831,17832],{},"ensuite, par pièce",[41,17834,17835,17838],{},[59,17836,17837],{},"Appareils sans ligne",[59,17839,17840],{},"pas d’adresse ; le résumé les compte, le contrôle les signale",[10,17842,17843],{},"Les adresses de groupe ont trois niveaux : groupe principal, groupe intermédiaire, sous-groupe. Dans la structure par défaut, le groupe principal est le corps de métier, le groupe intermédiaire l’étage (0 sans étage) et le sous-groupe l’objet numéroté à la suite.",[35,17845,17846,17859],{},[38,17847,17848],{},[41,17849,17850,17853,17856],{},[44,17851,17852],{},"Groupe principal",[44,17854,17855],{},"Corps de métier",[44,17857,17858],{},"Objets et type de point de données (DPT)",[54,17860,17861,17870,17880,17891,17901,17911,17921],{},[41,17862,17863,17865,17867],{},[59,17864,15519],{},[59,17866,15619],{},[59,17868,17869],{},"Commutation 1.001, état 1.001",[41,17871,17872,17874,17877],{},[59,17873,11333],{},[59,17875,17876],{},"Variation",[59,17878,17879],{},"Commutation 1.001, variation 3.007, valeur de luminosité 5.001, états 1.001 et 5.001",[41,17881,17882,17885,17888],{},[59,17883,17884],{},"3",[59,17886,17887],{},"Volets",[59,17889,17890],{},"Monter\u002Fdescendre 1.008, stop\u002Flamelles 1.007, position 5.001, état position 5.001",[41,17892,17893,17895,17898],{},[59,17894,15503],{},[59,17896,17897],{},"Chauffage",[59,17899,17900],{},"Consigne et valeur réelle 9.001, grandeur de réglage 5.001, mode 20.102",[41,17902,17903,17906,17908],{},[59,17904,17905],{},"5",[59,17907,12305],{},[59,17909,17910],{},"Objet de commutation 1.001 ; luminosité des détecteurs 9.004",[41,17912,17913,17915,17918],{},[59,17914,15516],{},[59,17916,17917],{},"Scènes",[59,17919,17920],{},"Scène 17.001",[41,17922,17923,17926,17929],{},[59,17924,17925],{},"7",[59,17927,17928],{},"Central",[59,17930,17931],{},"Commutation 1.001 ou monter\u002Fdescendre 1.008",[4534,17933],{":height":17488,":width":17489,"alt":17934,"caption":17935,"src":17936},"Adresses de groupe du groupe principal 1 Éclairage, groupe intermédiaire 1\u002F1 Appartement : ligne Plafonnier hall avec commutation 1\u002F1\u002F1 et état 1\u002F1\u002F2 côte à côte, type de point de données 1.001 avec son nom, dessous le bouton-poussoir et le renvoi vers 5\u002F1\u002F1.","Groupe principal Éclairage : une ligne par canal, commutation et état côte à côte, dessous le bouton-poussoir et la liaison du détecteur.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-addresses-groups.webp",[10,17938,17939,17940,17943],{},"Les adresses de groupe ne sont créées que pour les canaux qui ont au moins une charge ; un canal de réserve reste sans adresse. Chaque ligne montre un canal avec le nom de son récepteur ; commutation et état figurent côte à côte, chacun avec son type de point de données et son nom, les objets supplémentaires comme « +3 objets ». Un clic sur une adresse ouvre le champ de saisie. PlanElec verrouille automatiquement une adresse modifiée ; le cadenas (",[19,17941,17942],{},"Verrouiller l’adresse","), qui apparaît au survol, la verrouille explicitement. Chaque nouvelle proposition conserve les adresses verrouillées et ne réattribue pas leur numéro. Le contrôle signale les adresses en double ou invalides comme conflit.",[10,17945,17946],{},[26,17947],{"id":8496},[30,17949,17951],{"id":17950},"knx-uniquement-comment-télécharger-les-adresses-en-fichiers-pour-ets","KNX uniquement : comment télécharger les adresses en fichiers pour ETS ?",[261,17953,17954,17960,17976],{},[152,17955,17239,17956,17630,17958,4014],{},[19,17957,3930],{},[19,17959,4286],{},[152,17961,17962,17963,17965,17966,4004,17969,293,17972,17975],{},"Dans l’encadré ",[19,17964,8545],{},", téléchargez ",[19,17967,17968],{},"Adresses de groupe CSV (ETS)",[19,17970,17971],{},"Adresses de groupe XML (ETS)",[19,17973,17974],{},"Liste des adresses physiques CSV",". Sans proposition d’adresses, l’encadré vous invite à proposer d’abord les adresses.",[152,17977,17978],{},"Les fichiers suivent le format d’ETS pour les adresses de groupe. Appareils, paramètres et liaison des objets de communication se créent dans ETS ; vérifiez-y chaque adresse reprise.",[4534,17980],{":height":17981,":width":17717,"alt":17982,"caption":17983,"src":17984},"158","Encadré Préparation ETS dans l’export avec les boutons Adresses de groupe CSV (ETS), Adresses de groupe XML (ETS) et Liste des adresses physiques CSV.","Les trois fichiers de l’encadré Préparation ETS ; PlanElec ne crée pas de projet ETS.","\u002Fhelp\u002Fknx-ets-preparation\u002Ffr-export-ets.webp",[35,17986,17987,17995],{},[38,17988,17989],{},[41,17990,17991,17993],{},[44,17992,695],{},[44,17994,9196],{},[54,17996,17997,18008,18019],{},[41,17998,17999,18001],{},[59,18000,17968],{},[59,18002,18003,18004,18007],{},"Format « 3\u002F1 » : groupe principal, intermédiaire et sous-groupe, adresse, description, DPT en ",[14,18005,18006],{},"DPST-x-y"," ; virgule, UTF-8 avec BOM",[41,18009,18010,18012],{},[59,18011,17971],{},[59,18013,18014,18015,18018],{},"Export d’adresses de groupe au schéma XML ",[14,18016,18017],{},"http:\u002F\u002Fknx.org\u002Fxml\u002Fga-export\u002F01"," avec les noms de plages",[41,18020,18021,18023],{},[59,18022,17974],{},[59,18024,18025],{},"Ligne, adresse physique, appareil, type et pièce comme liste de travail",[10,18027,18028],{},"Les adresses de groupe ne portent aucune affectation aux objets de communication. C’est pourquoi la description de chaque adresse de groupe indique quelles touches, quels détecteurs ou quels participants de scène l’utilisent ; la liaison elle-même se fait dans ETS. Nous n’avons pas vérifié d’import avec une version d’ETS précise et ne le garantissons pas. Les exports ne dépendent pas de la validation du dossier : vous pouvez les télécharger dès le brouillon.",[10,18030,18031],{},[26,18032],{"id":180},[30,18034,18036],{"id":18035},"que-ne-prend-pas-en-charge-planelec","Que ne prend pas en charge PlanElec ?",[35,18038,18039,18049],{},[38,18040,18041],{},[41,18042,18043,18046],{},[44,18044,18045],{},"PlanElec fait",[44,18047,18048],{},"Reste dans le logiciel du fabricant ou sur chantier",[54,18050,18051,18059,18067,18075,18083,18091],{},[41,18052,18053,18056],{},[59,18054,18055],{},"Planifier et documenter tableau, canaux, borniers et lignes",[59,18057,18058],{},"Programmation des appareils, paramètres et logique",[41,18060,18061,18064],{},[59,18062,18063],{},"Plan des canaux, des borniers et des fonctions, topologie, quantités, dossier",[59,18065,18066],{},"Câblage sur chantier, plan conducteur par conducteur, commande",[41,18068,18069,18072],{},[59,18070,18071],{},"Budget bus avec valeurs saisies et estimées",[59,18073,18074],{},"Mesure du courant bus, diagnostic du bus, mise en service",[41,18076,18077,18080],{},[59,18078,18079],{},"Lignes logiques et câble de bus sur le plan",[59,18081,18082],{},"Relevé des chemins de câbles, mesure d’isolement",[41,18084,18085,18088],{},[59,18086,18087],{},"KNX uniquement : proposition d’adresses et fichiers au format d’ETS",[59,18089,18090],{},"Projet ETS (.knxproj), bases de données produits, objets de communication",[41,18092,18093,18096],{},[59,18094,18095],{},"Constats de planification et autocontrôle RGIE",[59,18097,18098],{},"Contrôle de l’installation par l’organisme agréé",[30,18100,18102],{"id":18101},"peut-on-voir-le-parcours-dans-le-studio","Peut-on voir le parcours dans le Studio ?",[10,18104,18105,18106,18109,18110,18113],{},"Oui. Dans le ",[19,18107,18108],{},"Centre d’apprentissage",", lancez la ",[19,18111,18112],{},"Visite domotique",". En trois minutes environ, elle montre le système, les étapes de planification, Placer un module, le tableau des canaux, les lignes, les fonctions et les documents dans l’export, pour KNX en plus les adresses et la préparation ETS, sans modifier votre projet. Les étapes dont la cible manque encore dans le projet sont passées.",[30,18115,8565],{"id":8564},[149,18117,18118,18122,18126,18130],{},[152,18119,18120],{},[26,18121,8167],{"href":12816},[152,18123,18124],{},[26,18125,8023],{"href":7981},[152,18127,18128],{},[26,18129,4615],{"href":4614},[152,18131,18132],{},[26,18133,4521],{"href":4520},{"title":822,"searchDepth":823,"depth":823,"links":18135},[18136,18137,18138,18139,18140,18141,18142,18143,18144,18145,18146,18147,18148,18149],{"id":17172,"depth":823,"text":17173},{"id":17233,"depth":823,"text":17234},{"id":17313,"depth":823,"text":17314},{"id":17382,"depth":823,"text":17383},{"id":17428,"depth":823,"text":17429},{"id":17503,"depth":823,"text":17504},{"id":17569,"depth":823,"text":17570},{"id":17622,"depth":823,"text":17623},{"id":17728,"depth":823,"text":17729},{"id":17758,"depth":823,"text":17759},{"id":17950,"depth":823,"text":17951},{"id":18035,"depth":823,"text":18036},{"id":18101,"depth":823,"text":18102},{"id":8564,"depth":823,"text":8565},"Pas à pas, du système d’automatisation au dossier : modules dans le tableau, boutons-poussoirs et détecteurs sur les canaux, plan des canaux pour la porte du tableau, plan des borniers, fonctions par pièce, lignes avec budget bus, brouillon ou final et travail en équipe – pour KNX, Niko Home Control, Loxone, Shelly, Sonoff ou neutre. Pour KNX, en plus les adresses et des fichiers pour ETS.","knx-ets-preparation","\u002Fimages\u002Fhelp\u002Fcovers-2026-11-01\u002Fknx-ets-preparation.webp",{},20,"\u002Fhelp\u002Fknx-ets-preparation.fr","2026-11-04","13 min",{"title":17151,"description":18150},"Planifier et documenter la domotique, pas à pas","planifier-une-installation-knx-et-preparer-ets","help\u002Fknx-ets-preparation.fr",[4286,8700,8344,8364,18163,8614,18164,17258,18165,18166],"Ligne de bus","Niko Home Control","Shelly","ETS","JZ4350OkaQho6ilCINSqG3HyV6l5oJqbvJQhzqJzlk0"]